Setup-Guide-Temperature-Nodes-Sensoscientific-Manual.Pdf
Total Page:16
File Type:pdf, Size:1020Kb
Quick Setup Guide Simple. Accurate. Reliable. OTA Temperature Nodes 1 Unpack Box Find the following items enclosed in your order To proceed with installation, you will need 1/2” - 1” Drill and a Phillips Head Screwdriver or Drill Bit OTA Node Node Holster Differential Mesh Wall Mount Pressure Probe Nozzle Wall Mount Tubing Mounting Tape Screws Batteries AC Power Cord (Optional) Connect Node to Wi-Fi 2 Follow steps 2.1 through 2.5 for a successful connection Opted for pre-configuration? Verify that the Wi-Fi, Internet, and Cloud symbols do not have a cross through them. Your Node is Insert four 1.5V now connected to the network! Once the Node batteries into the connects to Wi-Fi, back of the OTA skip to Step 3 If there are crosses, your Node is not connected Node to turn on to Wi-Fi. Please follow Steps 2.1 through 2.5 to “Install Device to the device. manually connect the device to Wi-Fi or contact Storage Unit” our technical support team for troubleshooting solutions: (800) 279-3101, Option 4 8/30/2019 Download SensoScientific’s Attach Probe and Set the Node to 2.1 Mobile App 2 .2 Turn On 2 .3 Provisioning Mode From your phone’s app store, search Attach the probe to the node by Once the Node alerts that it was not and download the SensoScientific app lining the probe connector’s 4 holes able to connect to the Cloud, press onto your mobile device. with the 4 pins in the M8 connector. the right and left arrows at the same Twist the metal fastener until secure. time until the display screen reads, Insert four 1.5V batteries into the back “Device is in provisioning mode!” of the OTA Node. Turn the switch to the ON position. Name Password Log In Wi-Fi Setup Connect Mobile Device to Connect OTA Node to 2 .4 OTA Node Wi-Fi 2 .5 Facility Wi-Fi From your phone’s Wi-Fi settings, connect to: mysimplelink- From the SensoScientific app’s login page, select the xxxxxx network. The ending numbers will match the last “Wi-Fi Setup” link. Select the Wi-Fi network you want 6 characters of the Node’s Mac Address found on the the Node to use. If your network is hidden, select display screen. “Other” from the list of SSIDs. Enter your credentials and click “Join”. Keep in mind that OTA Nodes require case- sensitive passwords. Install Device to Storage Unit 3 Follow steps 3.1 through 3.6 for the correct installation procedure Determine Location & Drill Hole Thread Tubing through Both Sides 3 .1 3.2 of the Wall Determine the desired location for pressure sensor and Thread the Tubing from one side of the wall to the other. tubing. Consult your facility manager for optimal location. Ensure the Tubing does not pinch or bend in a way that Consider necessary pressure measurement, nearby AC Power obstructs airflow pressure measurement. plugs, local regulation in installation procedure, and interfering pipes/insultation/electrical wiring. Drill a 1/2” - 1” hole through both sides of the determined location. Attach Mesh Wall Mount to Tubing Attach Nozzle Wall Mount to Tubing 3 .3 & Secure to Wall 3 .4 & Secure to Wall Move location to the opposing wall. Attach the Tubing to the Cut the Tubing 1” - 2” from the wall. Attach the Tubing to the Mesh Wall Mount’s interior nozzle. Secure the Mesh Wall Nozzle Wall Mount’s interior nozzle. Ensure the Tubing does Mount to the wall using Screws. not pinch or bend in a way that obstructs airflow pressure measurement. Secure the Nozzle Wall Mount to the wall using Screws. Secure Node & Probe to Wall Attach Nozzle Wall Mount to Probe 3.5 3.6 Using Tubing Using Screw or Mounting Tape, secure the Node Holster to Attach the Differential Pressure Probe to the Nozzle Wall the wall. Place the Node into the Node Holster until it snaps Mount by cutting Tubing to the appropriate size and securing into place. Using Screws or Strong Mounting Tape, secure the to the probe’s positive or negative input. Differential Pressure Probe to the wall. Establish Cloud Settings 4 Follow steps 4.1 through 4.4 for a successful cloud setup First log in to your account: cloud.sensoscientific.com A ALARM MONITORING REPORT CONFIGURATION CALIBRATION HELP Company Se�ngs Nodes User On Global Alarm Genera�on (On/Off) Group On Global Signal Alarm Genera�on (On/Off) B Se�ngs On Global Alarm No�fica�on (On/Off) C On Global Signal Alarm No�fica�on (On/Off) Configure On Global Signal Re-Alarm No�fica�on (On/Off) No�fica�on On Global Ba�ery Re-Alarm No�fica�on (On/Off) On Admin Audit Report (On/Off) All Types Select the type of no�fica�on that System Admin receives for selected nodes. Signal Alarm Guest User Group Admin Ba�ery Alarm Guest User Group Admin Calibra�on Alarms Guest User Group Admin Suspend Node Guest User Group Admin Enable Password Rules (At least one special character, one upper, one lower, one numerical digit Applicable for system admin, group admin, user, guest) Force a New User to Reset Password During First Login (Applicable for system admin, group admin, user, guest) 6 Months Password Validity Dura�on (Applicable for system admin, group admin, user, guest) Phone No�fica�on SMS No�fica�on Email No�fica�on Fax No�fica�on D Save Establish the Global 4 .1 Account Settings A Select the “CONFIGURATION” tab in the main menu. B Select the “Settings” tab in the submenu. C The submenu will reveal new options. Select the “Configure” tab. D Establish the desired settings and click the “Save” button at the bottom of the page. Establish the Global 4 .1 Account Settings A Select the “CONFIGURATION” tab in the main menu. B Select the “Settings” tab in the submenu. C The submenu will reveal new options. Select the “Configure” tab. D Establish the desired settings and click the “Save” button at the bottom of the page. A ALARM MONITORING REPORT CONFIGURATION CALIBRATION HELP Company Node Configura�on B Nodes Configure C Node ID Replace RMA Nodes Node MAC Address Ac�vated Spare Firmware Version (Only Applicable for OTA version node) Node User No Update OTA Upgrade Firmware Version (Only applicable for OTA version node) User Reset Node Min/Max values (Only applicable for OTA version node) Node Name (Please use le�ers and numbers only. Max 50 characters) Group (UTA-08:00) Pacific Time (US & Node Time Zone Se�ngs Loca�on Name (Please use le�ers and numbers only. Max 50 characters) No�fica�on Set Primary Alarm Limit Maximum Alarm Limit (Use only numbers) Minimum Alarm Limit (Use only numbers) Alarm Delay in Minutes (Use only numbers) Set Cri�cal Alarm Limit Maximum Alarm Limit (Use only numbers) Minimum Alarm Limit (Use only numbers) Alarm Delay in Minutes (Use only numbers) Re-Alarm Delay in Minute (Use only numbers) max 2 re-alarms On Speaker On/Off (Audible Alarm) (Only applicable for OTA version node) On Set Data Alarm Func�on (On/Off) On Set Signal Alarm Func�on (On/Off) On Set Ba�ery Alarm Func�on (On/Off) On Set Email No�fica�on (On/Off) On Set SMS No�fica�on (On/Off) On Set Re-Alarm No�fica�on (On/Off) On Set Voice No�fica�on (On/Off) On Set Fax No�fica�on (On/Off) On Audit Node (On/Off) °F Measurement Unit E Save Configure Node’s 4 .2 Operation Settings A Select the “CONFIGURATION” tab in the main menu. B Select the “Nodes” tab in the submenu. C The submenu will reveal new options. Select the “Configure” tab. D Click the “Configure” button of the desired node. (Not Displayed) E Establish the desired settings and click the “Save” button at the bottom of the page. NOTE: Refer to section “IV.2 Node Configuration” of the Cloud Manual for more information on field meanings. HELP > User Guide/Installation Docs > Cloud User Manual.pdf Configure Node’s 4 .2 Operation Settings A Select the “CONFIGURATION” tab in the main menu. B Select the “Nodes” tab in the submenu. C The submenu will reveal new options. Select the “Configure” tab. D Click the “Configure” button of the desired node. (Not Displayed) E Establish the desired settings and click the “Save” button at the bottom of the page. NOTE: Refer to section “IV.2 Node Configuration” of the Cloud Manual for more information on field meanings. HELP > User Guide/Installation Docs > Cloud User Manual.pdf A ALARM MONITORING REPORT CONFIGURATION CALIBRATION HELP Company Create a New User Nodes B User Valid Username (Should be Email Address) Min 6 and max 50 characters New User C First Name (Min 2 and max 15 characters) Configure Last Name (Min 2 and max 15 characters) Valid User Password (Min 6 max 16 characters) Add/Remove Node Retype Password (Min 2 and max 15 characters) Change Password On Signal, data, ba�ery Alarm Email No�fica�on On/Off Group On Alarm Confirma�on Email No�fica�on On/Off On Calibra�on Due Date No�fica�on On/Off Se�ngs Valid No�fica�on Email Address (Max 200 characters) No�fica�on On Automa�c Daily Report On/Off On Automa�c Daily Hourly Report (On/Off) On Automa�c Daily Excep�on (On/Off) On Automa�c Weekly Report (On/Off) On Automa�c Monthly Report (On/Off) On Automa�c Summary Report (On/Off) On Automa�c Two Point Monitoring (On/Off) Valid Report Email Address (Max 200 characters) On SMS No�fica�on On/Off Valid No�fica�on SMS Number (SMS No�fica�on must be On.) On Voice No�fica�on On/Off Valid No�fica�on Phone Number (Voice No�fica�on must be On.) On Fax No�fica�on On/Off Valid No�fica�on Fax Number (Fax numbers work only in U.S.) User Select user level type no auto refresh Set Auto Refresh on Current Status Instantly Select to receive no�fica�ons instantly or by escala�on Escala�on �me before no�fica�ons are sent (in minutes, max 4 digits) Standard Time Select Time Format Instantly Select Report Time Zone D Add New User Create New User's 4 .3 Personal Profile A Select the “CONFIGURATION” tab in the main menu.