INTERIOR AND EXTERIOR ARCHITECTURAL PRODUCTS Why JointMaster?

At JointMaster® we protect buildings from natural shifting and movement with expansion joint systems engineered to handle every condition. We realize that different buildings have different needs, so we have a team of experts on hand to help with your project specific conditions.

Obsessively Engineered We constantly test and review our systems to create designs engineered to meet your needs. Whether it’s applying tapered plates for maximum durability and longevity, noise dampening elements in consideration of noise pollution or using recycled tires as an eco-friendly option – we continuously innovate to provide you with the best solutions.

We Protect Every Building From stadiums to schools, pediatric centers to parking garages, you can count on us to provide the movement protection that your building requires.

Experienced Experts Let us eliminate your toughest challenges so you can focus on more important things like your building’s design and construction. Consult our team of experts about joint system selection and installation methods. We will even come to your office or site.

2 800.222.5556 | Installation Hotline: 866.ezinpro Expansion Joint S yst e ms

Owensboro Medical Health Center, Owensboro, Kentucky 601 Stealth inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 3 Floor Systems

Joint Movement System Type Series Models Loading Class Opening +/- Surface Mount, Flush Mount – Pages 10-15 101 103-110 1"-3" 25% 100 Series 120 25mm – Standard of Joint Width 132/133 75mm 141 Recessed Mount – Pages 16-17

221 2"-36" 25%-100% Standard 200 Series 222 50mm – of Joint Width Moderate 223 900mm

Glide Plate – Pages 18-19 300 2"-6" 304 50%-100% 300 Series 50mm – Standard 312 of Joint Width 150mm 320 Centering Bar – Pages 20-23 401 421/423/425 1"-18" Standard 50%-100% 400 Series 426/427/428 25mm – Moderate of Joint Width 430/432 450mm Heavy Duty 441/461/471 Heavy Duty – Pages 24-26 721/723/725 2"-12" Standard 741 50%-100% 700 Series 50mm – Moderate 757/767 of Joint Width 300mm Heavy Duty 787 Standard Cover Plate – Pages 28-29 801 804 1"-12" 25%-100% Standard 800 Series 806 25mm – of Joint Width Moderate 802/807 300mm 808 Single Sightline – Page 30

2"-4" 50%-100% 300 Series 316 50mm – Moderate of Joint Width 100mm

Pan Systems – Page 31

2"-8" 501 50%-100% Moderate 500 Series 50mm – 502 of Joint Width Heavy Duty 200mm

4 800.222.5556 | Installation Hotline: 866.ezinpro Wall and Ceiling Systems

Joint Movement System Type Series Models Loading Class Opening +/- Drywall Finishes – Pages 34-37 101 112 1"-6" 25%-50% 100 Series 113 25mm – N/A of Joint Width 114 150mm 611 Drywall Finishes, Flush Mount – Pages 38-40 221 223 2"-36" 50%-100% 200 Series 233 50mm – N/A of Joint Width 243 900mm 253 Glide Plate – Pages 42-43

1"-6" 300 50%-100% 300 Series 25mm – N/A 318 of Joint Width 150mm

Centering Bar – Page 43

2"-24" 481 50%-100% 400 Series 50mm – N/A 491 of Joint Width 600mm Expansion Joint S yst e ms

Surface Mount – Pages 44-45

811 1"-6" 25%-100% 800 Series 104 25mm – N/A of Joint Width 118 150mm

Acoustical Ceiling – Page 35

1"-2" 50%-100% 800 Series 821 25mm – N/A of Joint Width 50 mm

Acoustical Ceiling – Page 36

2"-4" 50%-100% 100 Series 115 50mm – N/A of Joint Width 100mm

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 5 Exterior Joint Systems

Joint Movement System Type Series Models Loading Class Opening +/- Seal Systems – Pages 48-49

615 2"-36" 616 50%-100% 600 Series 50mm – N/A 620 of Joint Width 600mm 621

Surface Mount – Pages 50-51

2"-24" 601 Stealth™ 50%-100% 600 Series 50mm – N/A 651 of Joint Width 600mm

Metal Roofing System – Pages 52-53

651 2"-8" 50% 600 Series 661 50mm – N/A of Joint Width 691 200mm

Bellow System – Page 54

2"-36" 672 50%-100% 600 Series 50mm – N/A 674 of Joint Width 900 mm

6 800.222.5556 | Installation Hotline: 866.ezinpro Seals and Accessories

Joint Movement Load/Rating System Type Series Models Opening +/- Class Foam Seals – Page 56

1/2"-20" 1200 25%-100% 1200 Series 12.7mm – N/A 1250 of Joint Width 508mm

Foam Seals – Page 57

1100 1"-12" 25%-100% 1100 Series 1150 25.4mm – Standard of Joint Width 1175 304.8mm

Compression Seals – Page 58

AR 1"-4" Compression 25%-50% CR 25mm – Heavy Duty Seals of Joint Width DR 100mm

Fire Barriers – Pages 60-61

975

950 1"-36" 2hr Expansion Joint S yst e ms 25%-100% 900 Series 921/925 25.4mm – 3hr of Joint Width 935 914.4mm 4hr 990/995

Vapor and Insulated Barriers – Page 62

1"-36" IVB 25%-100% Barriers 25.4mm – N/A RVB of Joint Width 914.4mm

Facility Protection – Pages 63-65

Speed Guards Tire Stop Facility Corner Guards N/A N/A N/A Protection Wall Guards Dock Bumper

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 7 Model Number Guide

101 - A01 - 025 Series/ Model Condition Joint Number Width

CONDITION SEAL COLOR

FRAME HEIGHT

JOINT WIDTH

Series | Model Loading Definitions 100 Elastomeric Seal Systems for Floors / Walls / Ceilings Standard / Moderate / and Heavy Duty are designations 200 Dual Elastomeric Seal Systems for Floors / Walls / Ceilings as they relate to load ratings. These are provided as 300 Glide Plate Seismic Systems for Floors / Walls / Ceilings a guideline to assist in making a preliminary product 400 Center Bar Seismic Systems for Floors / Walls / Ceilings selection for a given application. 500 Seismic “Pop-up” Systems for Floors and Walls 600 Exterior Seismic Systems for Walls and Roofs ••“Standard” suggests use in common applications such 700 Heavy Duty Seismic Systems for Floors as typical office settings or other spaces where pedestrian traffic or occasional rubber-wheeled traffic like mail carts 800 Cover Plate Systems for Floors / Walls / Ceilings and light-weight cleaning equipment, luggage, etc. is 900 Fire Barrier Systems the norm. 1000 Exterior Compression Seals ••“Moderate” suggests applications where occasional heavier 1100 Foam Seals maintenance equipment with soft rubber tires (such as 1200 Silicone Foam Seals light duty scissor lifts, motorized cleaning equipment, etc.) would be added to the standard traffic. The systems in this Location category are comprised of heavier aluminum extrusions, A01 Floor to Floor with thicker walled extruded rubber inserts. A02 Floor to Wall ••“Heavy Duty” is for applications where truly heavy loads A07 Wall to Wall or Ceiling to Ceiling (such as vehicles) or high-point loads (such as gurneys, A09 Wall to Corner or Ceiling to Wall mobile medical equipment, coin carts, materials handling V18 Ceiling to Wall for Acoustical Ceiling Systems equipment, etc.) are the norm. They are capable of multi- V24 Ceiling to Ceiling for Acoustical Ceiling Systems directional movements and are also available in surface or G01 Curb to Curb or Roof to Roof blockout mounted variations. G02 Curb to Wall or Roof to Wall ••Contact your JointMaster® representative for more details on project specific loading conditions. Joint Width 025 1" (25mm) 400 16" (400mm) 038 1½" (38mm) 450 18" (450mm) 050 2" (51mm) 500 20" (500mm) 075 3" (76mm) 600 24" (600mm) 100 4" (102mm) 150 6" (150mm) 200 8" (200mm) 300 12" (300mm) 350 14" (350mm)

8 800.222.5556 | Installation Hotline: 866.ezinpro Floor Systems

JointMaster® offers a variety of Floor Systems for both Thermal and Seismic applications. From minimal sightlines to high load ratings, JointMaster Floor Systems are designed to perform no matter the challenge. Expansion Joint S yst e ms

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 9 Floor Systems - Surface Mount

••Dual durometer seal provides secure fit and optimal flexibility. ••Frames adaptable to multiple floor finishes including concrete, VCT, Surface mount designs make systems ideal sheet vinyl and carpet. for renovations. 100 Series systems allow for ••Snap-fit design for easy on-site assembly. Standard loading conditions such as offices, ••Optional integral vapor barrier available. restaurants, cafeterias and clean rooms. ••Integrates with the following wall and ceiling systems: ••101-A07/A09 ••104-A07/A09 ••112-A07/A09 % of MOVEMENT VAPOR BARRIER ±25% optional ••113-A07/A09 ••118-A07/A09 JOINT WIDTH fire rated ••Mill finish standard. 1" (25mm) – 3" (76mm) optional ••Standard and custom seal colors available, see pages 66-67.

103 Series – VCT

A01 Floor/Floor A02 Floor/Wall (2" (51mm) system shown) (2" (51mm) system shown) S

S H2 H2 H1

H1 W W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 103-A01-025 1" 25 5/8" 16 1/8" 4 4" 102 * * 1/4" 6 1/4" 6 103-A01-038 1 1/ " 38 5/ " 16 1/ " 4 4 1/ " 114 * * 3/ " 10 3/ " 10 Floor to Floor 2 8 8 2 8 8 103-A01-050 2" 51 1" 25 1/8" 4 4 7/8" 124 * * 1/2" 13 1/2" 13 103-A01-075 3" 76 1 1/8" 28 1/8" 4 6" 152 * * 3/4" 19 3/4" 19 103-A02-025 1" 25 5/8" 16 1/8" 4 2 1/2" 64 * * 1/4" 6 1/4" 6 103-A02-038 1 1/ " 38 5/ " 16 1/ " 4 2 15/ " 75 * * 3/ " 10 3/ " 10 Floor to Wall 2 8 8 16 8 8 103-A02-050 2" 51 1" 25 1/8" 4 3 3/8" 86 * * 1/2" 13 1/2" 13 103-A02-075 3" 76 1 1/8" 28 1/8" 4 4 1/2" 114 * * 3/4" 19 3/4" 19

10 800.222.5556 | Installation Hotline: 866.ezinpro 104 Series – Sheet Vinyl or Concrete A01 Floor/Floor A02 Floor/Wall (2" (51mm) system shown) (2" (51mm) system shown) S H1 H1 W Not available online: A02-025, A02-050 W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 104-A01-025 1" 25 5/8" 16 * * 4 3/4" 121 * * 1/4" 6 1/4" 6 1 5 1 3 3 Floor to Floor 104-A01-038 1 /2" 38 /8" 16 * * 5 /8" 131 * * /8" 10 /8" 10 104-A01-050 2" 51 1" 25 * * 5 5/8" 143 * * 1/2" 13 1/2" 13 104-A01-075 3" 76 1 1/8" 28 * * 6 5/8" 169 * * 3/4" 19 3/4" 19 104-A02-025 1" 25 5/8" 16 * * 2 7/8" 73 * * 1/4" 6 1/4" 6 1 5 5 3 3 Floor to Wall 104-A02-038 1 /2" 38 /8" 16 * * 3 /16" 84 * * /8" 10 /8" 10 104-A02-050 2" 51 1" 25 * * 3 3/4" 95 * * 1/2" 13 1/2" 13 104-A02-075 3" 76 1 1/8" 28 * * 4 3/4" 121 * * 3/4" 19 3/4" 19

105 Series – Sheet Vinyl

A01 Floor/Floor A02 Floor/Wall (2" (51mm) system show) (2" (51mm) system shown) S H1 H2

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 105-A01-025 1" 25 5/8" 16 1/8" 3 1" 25 * * 1/4" 6 1/4" 6 1 5 1 1 3 3 Floor to Floor 105-A01-038 1 /2" 38 /8" 16 /8" 3 1 /2" 36 * * /8" 10 /8" 10 105-A01-050 2" 51 1" 25 1/8" 3 2" 47 * * 1/2" 13 1/2" 13

105-A01-075 3" 76 1 1/8" 28 1/8" 3 3" 73 * * 3/4" 19 3/4" 19 Expansion Joint S yst e ms 105-A02-025 1" 25 5/8" 16 1/8" 3 1" 25 * * 1/4" 6 1/4" 6 1 5 1 1 3 3 Floor to Wall 105-A02-038 1 /2" 38 /8" 16 /8" 3 1 /2" 36 * * /8" 10 /8" 10 105-A02-050 2" 51 1" 25 1/8" 3 2" 47 * * 1/2" 13 1/2" 13 105-A02-075 3" 76 1 1/8" 28 1/8" 3 3" 73 * * 3/4" 19 3/4" 19

106 Series – Carpet

A01 Floor/Floor A02 Floor/Wall (2" (51mm) system shown) (2" (51mm) system shown)

S H1 H2

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 106-A01-025 1" 25 5/8" 16 1/4" 6 1" 25 * * 1/4" 6 1/4" 6 1 5 1 1 3 3 Floor to Floor 106-A01-038 1 /2" 38 /8" 16 /4" 6 1 /2" 36 * * /8" 10 /8" 10 106-A01-050 2" 51 1" 25 1/4" 6 2" 47 * * 1/2" 13 1/2" 13 106-A01-075 3" 76 1 1/8" 28 1/4" 6 3" 73 * * 3/4" 19 3/4" 19 106-A02-025 1" 25 5/8" 16 1/4" 6 1" 25 * * 1/4" 6 1/4" 6 1 5 1 1 3 3 Floor to Wall 106-A02-038 1 /2" 38 /8" 16 /4" 6 1 /2" 36 * * /8" 10 /8" 10 106-A02-050 2" 51 1" 25 1/4" 6 2" 47 * * 1/2" 13 1/2" 13 106-A02-075 3" 76 1 1/8" 28 1/4" 6 3" 73 * * 3/4" 19 3/4" 19 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 11 Floor Systems - Flush, Recessed

••Surface mount design makes systems ideal for renovations (132, 133, 141 systems). Flush mount frames are adaptable to ••Dual durometer seal provides secure fit and optimal flexibility. any floor finish. 100 Series systems are ••Snap-fit design for easy on-site assembly. ideal for Standard loading conditions ••Optional integral vapor barrier (101 system) slides directly into such as those encountered in showrooms, frame for easy installation. restrooms and lobbies. ••Integrates with the following wall and ceiling systems: ••101-A07/A09 ••112-A07/A09 ••113-A07/A09 % of MOVEMENT VAPOR BARRIER ±25% optional ••118-A07/A09 ••Mill finish standard. JOINT WIDTH fire rated ••Standard and custom seal colors available, see pages 66-67. 1" (25mm) – 3" (76mm) optional

101 Series – Any Floor Type S A01 Floor/Floor A02 Floor/Wall (2" (51mm) system shown) (1" (25mm) system shown) S H1 H1 W W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 101-A01-025 1" 25 1 1/2" 38 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6 101-A01-038 1 1/ " 38 1 1/ " 38 * * 1 7/ " 36 2 1/ " 64 3/ " 10 3/ " 10 Floor to Floor 2 2 16 2 8 8 101-A01-050 2" 51 1 1/2" 38 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 101-A01-075 3" 76 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 3/4" 19 3/4" 19 101-A02-025 1" 25 1 1/2" 38 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6 101-A02-038 1 1/ " 38 1 1/ " 38 * * 1 7/ " 36 2 1/ " 64 3/ " 10 3/ " 10 Floor to Wall 2 2 16 2 8 8 101-A02-050 2" 51 1 1/2" 38 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 101-A02-075 3" 76 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 3/4" 19 3/4" 19 Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

12 800.222.5556 | Installation Hotline: 866.ezinpro 120 Series – Any Floor Type

A01 Floor/Floor A02 Floor/Wall S 1" (25mm) system shown) S 1" (25mm) system shown)

H1 H1H1 W

WW

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 120-A01-025 1 " 25 1"-1 1/2"-2" 25-38-50 * * 1" 25 2 1/ " 64 1/4" 6 1/4" 6 Floor to Floor 2 120-A01-038 1 1/2" 38 1"-1 1/2"-2" 25-38-50 * * 1 3/8" 35 2 1/2" 64 3/8" 10 3/8" 10 120-A02-025 1" 25 1"-1 1/2"-2" 25-38-50 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6 Floor to Wall 120-A02-038 1 1/2" 38 1"-1 1/2"-2" 25-38-50 * * 1 3/18" 36 2 1/2" 64 3/8" 10 3/8" 10 Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

132 - Sheet Vinyl 133 - Carpet Series 133-A01 Floor/Floor 132-A02 Floor/Wall 2" (51mm) system shown) 2" (51mm) system shown) H2H2 S S H2H2 SS

H1H1 H1H1

WW WW

W H1 H2 S B Movement +/- Expansion Joint S yst e ms Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 132-A01-050 2" 50 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 132-A01-075 3" 75 5/ " 16 1/ " 3 1 7/ " 47 2 1/ " 64 1/ " 13 1/ " 13 Floor to Floor 8 8 8 2 2 2 133-A01-050 2" 50 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 133-A01-075 3" 75 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 132-A02-050 2" 50 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 132-A02-075 3" 75 5/ " 16 1/ " 3 1 7/ " 47 2 1/ " 64 1/ " 13 1/ " 13 Floor to Wall 8 8 8 2 2 2 133-A02-050 2" 50 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13 133-A02-075 3" 75 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13

141 - Carpet and VCT S H1 H2 A01 Floor/Floor 2" (51mm) system shown)

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 141-A01-025 1" 25 5/8" 16 * * 5 5/8" 142 2 3/4" 70 1/4" 6 1/4" 6 Floor to Floor 141-A01-038 1 1/2" 35 5/8" 16 * * 6" 153 2 3/4" 70 3/8" 10 3/8" 10 141-A01-050 2" 50 5/8" 16 * * 6 1/2" 164 2 3/4" 70 1/2" 13 1/2" 13 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 13 Floor Systems - New to Existing

••Dual durometer seal provides secure fit and optimal flexibility. This series is designed for retrofits, additions ••Snap-fit design allows easy on-site assembly. and renovations where blockout occurs on ••Optional integral vapor barrier slides directly into frame for one side only. 100 systems allow for Standard easy installation. loading conditions such as offices, cafeterias ••Integrates with the following wall and ceiling systems: and clean rooms. ••101-A07/A09 ••104-A07/A09 % of MOVEMENT VAPOR BARRIER ••112-A07/A09 ±25% optional ••113-A07/A09 ••Mill finish standard. JOINT WIDTH fire rated 1" (25mm) – 3" (76mm) optional ••Standard and custom seal colors available, see pages 66-67.

107 Series - Finished Concrete

A01 Floor/Floor (1" (25mm) system shown) S H1

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 107-A01-025 1" 25 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 1/4" 6 1/4" 6 107-A01-038 1 1/ " 38 1 1/ " 38 * * 3 5/ " 84 2 1/ " 64 3/ " 10 3/ " 10 Floor to Floor 2 2 16 2 8 8 107-A01-050 2" 51 1 1/2" 38 * * 3 3/4" 95 2 1/2" 64 1/2" 13 1/2" 13 107-A01-075 3" 76 1 1/2" 38 * * 4 3/4" 121 2 1/2" 64 3/4" 19 3/4" 19 Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

14 800.222.5556 | Installation Hotline: 866.ezinpro 108 Series - Sheet Vinyl A01 Floor/Floor (1" (25mm) system shown) S H2 H1

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 108-A01-025 1" 25 1 1/2" 38 1/8" 3 1" 25 2 1/2" 64 1/4" 6 1/4" 6 108-A01-038 1 1/2" 38 1 1/2" 38 1/8" 3 1 1/2" 36 2 1/2" 64 3/8" 10 3/8" 10 Floor to Floor 108-A01-050 2" 51 1 1/2" 38 1/8" 3 2' 47 2 1/2" 64 1/2" 13 1/2" 13 108-A01-075 3" 76 1 1/2" 38 1/8" 3 3" 73 2 1/2" 64 3/4" 19 3/4" 19 Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

109 Series - Carpet A01 Floor/Floor S (1" (25mm) system shown) H2 H1

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 109-A01-025 1" 25 1 1/2" 38 1/4" 6 1" 25 2 1/2" 64 1/4" 6 1/4" 6 109-A01-038 1 1/ " 38 1 1/ " 38 1/ " 6 1 1/ " 36 2 1/ " 64 3/ " 10 3/ " 10 Floor to Floor 2 2 4 2 2 8 8 109-A01-050 2" 51 1 1/2" 38 1/4" 6 2" 47 2 1/2" 64 1/2" 13 1/2" 13 109-A01-075 3" 76 1 1/2" 38 1/4" 6 3" 73 2 1/2" 64 3/4" 19 3/4" 19 Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available. Expansion Joint S yst e ms

110 Series - VCT A01 Floor/Floor S (2" (51mm) system shown) H2 H1

W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 110-A01-025 1" 25 1 1/2" 38 1/8" 4 2 1/2" 64 2 1/2" 64 1/4" 6 1/4" 6 110-A01-038 1 1/ " 38 1 1/ " 38 1/ " 4 2 5/ " 75 2 1/ " 64 3/ " 10 3/ " 10 Floor to Floor 2 2 8 6 2 8 8 110-A01-050 2" 51 1 1/2" 38 1/8" 4 3 3/8" 86 2 1/2" 64 1/2" 13 1/2" 13 110-A01-075 3" 76 1 1/2" 38 1/8" 4 4 1/2" 113 2 1/2" 64 3/4" 19 3/4" 19 Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 15 Floor Systems - Recessed Mount

••Recessed mount frames for minimal sightline, adaptable with Snap-fit design for easy on-site assembly. 200 many floor finishes. Series systems allow for Moderate loading ••Dual durometer seal provides secure fit and optimal flexibility. applications while meeting a wide range of ••Double seals absorb limited serviceable seismic movement. joint sizes. ••Integrates with the following wall and ceiling systems: ••221-A07/A09 % of MOVEMENT VAPOR BARRIER ••223-A07/A09 ±50% optional ••233-A07/A09 ••Mill finish standard. JOINT WIDTH fire rated ••Standard and custom seal colors available, see pages 66-67. 2 " (50mm – 6" (150mm) optional

221 Series - Any Flooring Type (Flush) A01 Floor/Floor (4" (100mm) system shown) S H1

W

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 221-A01-050 2" 51 5/8" 16 4 7/8" 124 1 1/2" 13 1” 25 1” 25 221-A01-100 4" 102 5/8" 16 9 3/8" 238 2 3/4" 70 2” 51 2” 51 221-A01-150 6" 152 5/8" 16 11 3/8" 289 2 3/4" 70 3” 75 3” 75 221-A01-200 8" 200 5/8" 16 18" 457 4 1/2" 114 4” 102 4” 102 Floor to Floor 221-A01-250 10" 250 5/8" 16 21" 533 4 1/2" 114 5” 125 5” 125 221-A01-300 12" 300 5/8" 16 24" 609 4 1/2" 114 6” 152 6” 152 221-A01-350 14" 350 5/8" 16 27" 686 4 1/2" 114 7” 178 7” 178 221-A01-400 16" 400 5/8" 16 30" 762 4 1/2" 114 8” 203 8” 203 221-A01-450 18" 450 5/8" 16 33" 838 4 1/2" 114 9” 228 9” 228 221-A02-050 2" 51 5/8" 16 3 1/2" 89 1 1/2" 13 1/4" 6 1/4" 6 221-A02-100 4" 102 5/8" 16 6 5/8" 168 2 3/4" 70 1/2" 13 1/2" 13 221-A02-150 6" 152 5/8" 16 8 5/8" 219 2 3/4" 70 1/2" 13 1/2" 13 221-A02-200 8" 200 5/8" 16 13" 330 4 1/2" 114 2 51 2 51 Floor to Wall 221-A02-250 10" 250 5/8" 16 15 1/2" 394 4 1/2" 114 2 1/2" 64 2 1/2" 64 221-A02-300 12" 300 5/8" 16 18" 457 4 1/2" 114 3 76 3 76 221-A02-350 14" 350 5/8" 16 20 1/2" 521 4 1/2" 114 3 1/2" 89 3 1/2" 89 221-A02-400 16" 400 5/8" 16 23" 584 4 1/2" 114 4 102 4 102 221-A02-450 18" 450 5/8" 16 25 1/2" 648 4 1/2" 114 4 1/2" 114 4 1/2" 114 Larger sizes available

16 800.222.5556 | Installation Hotline: 866.ezinpro 222 Series - VCT S SS H2H2

A01 Floor/Floor for VCT H1 4" (100mm) system shown) H1

WW

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 222-A01-050 2" 51 5/8" 16 1/8" 3 2" 51 1 1/2" 13 1” 25 1” 25 222-A01-100 4" 102 5/8" 16 1/8" 3 4" 102 2 3/4" 70 2” 51 2” 51 222-A01-150 6" 152 5/8" 16 1/8" 3 4" 102 2 3/4" 70 3” 75 3” 75 222-A01-200 8" 200 5/8" 16 1/8" 3 6" 152 4 1/2" 114 4” 102 4” 102 Floor to Floor 222-A01-250 10" 250 5/8" 16 1/8" 3 6" 152 4 1/2" 114 5” 125 5” 125 222-A01-300 12" 300 5/8" 16 1/8" 3 6" 152 4 1/2" 114 6” 152 6” 152 222-A01-350 14" 350 5/8" 16 1/8" 3 6" 152 4 1/2" 114 7” 178 7” 178 222-A01-400 16" 400 5/8" 16 1/8" 3 6" 152 4 1/2" 114 8” 203 8” 203 222-A01-450 18" 450 5/8" 16 1/8" 3 6" 152 4 1/2" 114 9” 228 9” 228 222-A02-050 2" 51 5/8" 16 1/8" 3 1" 25 1 1/2" 13 1/4" 6 1/4" 6 222-A02-100 4" 102 5/8" 16 1/8" 3 2" 51 2 3/4" 70 1/2" 13 1/2" 13 222-A02-150 6" 152 5/8" 16 1/8" 3 2" 51 2 3/4" 70 1/2" 13 1/2" 13 222-A02-200 8" 200 5/8" 16 1/8" 3 3" 152 4 1/2" 114 2 51 2 51 Floor to Wall 222-A02-250 10" 250 5/8" 16 1/8" 3 3" 152 4 1/2" 114 2 1/2" 64 2 1/2" 64 222-A02-300 12" 300 5/8" 16 1/8" 3 3" 152 4 1/2" 114 3 76 3 76 222-A02-350 14" 350 5/8" 16 1/8" 3 3" 152 4 1/2" 114 3 1/2" 89 3 1/2" 89 222-A02-400 16" 400 5/8" 16 1/8" 3 3" 152 4 1/2" 114 4 102 4 102 222-A02-450 18" 450 5/8" 16 1/8" 3 3" 152 4 1/2" 114 4 1/2" 114 4 1/2" 114

223 Series - Tile or Carpet (3/8"/10mm) A01 Floor/Floor for 3/8" (10mm) Floor Finishes (4" (100mm) system shown) SS S H2H2

H1H1 Expansion Joint S yst e ms

WW

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 223-A01-050 2" 51 5/8" 16 3/8" 10 2" 51 1 1/2" 13 1” 25 1” 25 223-A01-100 4" 102 5/8" 16 3/8" 10 4" 100 2 3/4" 70 2” 51 2” 51 223-A01-150 6" 152 5/8" 16 3/8" 10 4" 100 2 3/4" 70 3” 75 3” 75 223-A01-200 8" 200 5/8" 16 1/4" 7 6" 152 5" 114 4” 102 4” 102 Floor to Floor 223-A01-250 10" 250 5/8" 16 1/4" 7 6" 152 5 1/2" 114 5” 125 5” 125 223-A01-300 12" 300 5/8" 16 1/4" 7 6" 152 6" 114 6” 152 6” 152 223-A01-350 14" 350 5/8" 16 1/4" 7 6" 152 6 1/2" 114 7” 178 7” 178 223-A01-400 16" 400 5/8" 16 1/4" 7 6" 152 7" 114 8” 203 8” 203 223-A01-450 18" 450 5/8" 16 1/4" 7 6" 152 7 1/2" 114 9” 228 9” 228 223-A02-050 2" 51 5/8" 16 3/8" 10 1" 25 1 1/2" 13 1/4" 6 1/4" 6 223-A02-100 4" 102 5/8" 16 3/8" 10 2" 51 2 3/4" 70 1/2" 13 1/2" 13 223-A02-150 6" 152 5/8" 16 3/8" 10 2" 51 2 3/4" 70 1/2" 13 1/2" 13 223-A02-200 8" 200 5/8" 16 1/4" 7 3" 76 5" 114 2 51 2 51 Floor to Wall 223-A02-250 10" 250 5/8" 16 1/4" 7 3" 76 5 1/2" 114 2 1/2" 64 2 1/2" 64 223-A02-300 12" 300 5/8" 16 1/4" 7 3" 76 6" 114 3 76 3 76 223-A02-350 14" 350 5/8" 16 1/4" 7 3" 76 6 1/2" 114 3 1/2" 89 3 1/2" 89 223-A02-400 16" 400 5/8" 16 1/4" 7 3" 76 7" 114 4 102 4 102 223-A02-450 18" 450 5/8" 16 1/4" 7 3" 76 7 1/2" 114 4 1/2" 114 4 1/2" 114

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 17 Floor Systems - Glide Plate

••Exclusive patented “no-bump" configuration makes system ADA compliant (patent #5384996). Glide plate cover provides a smooth and durable transition over expansion ••Cover plates rest on high durometer seals to eliminate system rattle. joints. 300 Series systems meet ••Mill finish standard. Standard to Moderate loading ••Available finish options on pages 66-67. conditions, are seismic-capable and % of MOVEMENT VAPOR BARRIER have unlimited shear movement. Ideal ±50% optional for public areas such as schools, civic centers and airports. JOINT WIDTH fire rated 1" (50mm) – 6" (152mm) optional

300 Series - Recessed Mount

Concealed hardware configuration makes system tamper proof for public space applications.

Recessed frame accommodates all floor finishes including concrete, terrazzo, tile, VCT and carpet.

Smooth transition ideal for rolling carts.

A01 Floor/Floor S (2" (51mm) system shown) A02 Floor/Wall S (2" (51mm) system shown) H1 H1

W W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal US mm US mm US mm US mm US mm US mm 300-A01-025 1" 25 1" 25 * * 3 1/4" 83 2 3/4" 70 1/2" 13 300-A01-050 2" 51 1" 25 * * 5 1/4" 133 3 1/4" 83 1" 25 Floor to Floor 300-A01-075 3" 76 1" 25 * * 7 1/8" 181 3 3/4" 95 1 1/2" 38 300-A01-100 4" 102 1" 25 * * 9 1/8" 232 4 1/4" 108 2" 51 300-A01-150 6" 152 1" 25 * * 13 1/8" 333 5 1/4" 133 3" 76 300-A02-025 1" 25 1" 25 * * 2 1/8" 5 2 3/4" 70 1/8" 3 300-A02-050 2" 51 1" 25 * * 3 5/8" 92 3 1/4" 83 3/8" 10 Floor to Wall 300-A02-075 3" 76 1" 25 * * 5" 127 3 3/4" 95 9/16" 14 300-A02-100 4" 102 1" 25 * * 6 5/8" 168 4 1/4" 108 3/4" 19 300-A02-150 6" 152 1" 25 * * 9 1/2" 241 5 1/4" 133 1 1/4" 31

18 800.222.5556 | Installation Hotline: 866.ezinpro 304 Series - Recessed Mount/VCT A02 Floor/Wall (2" (51mm) system shown) A01 Floor/Floor S (2" (51mm) system shown) S H2 H2 H1 H1

W W ••1/8" (3mm) nosing designed specifically for vinyl floors.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal US mm US mm US mm US mm US mm US mm 304-A01-025 1" 25 1" 25 1/8" 3" 2 5/8" 67 2 3/4" 70 1/2" 13 304-A01-050 2" 51 1" 25 1/8" 3" 3 5/8" 92 3 1/4" 83 1" 25 Floor to Floor 304-A01-075 3" 76 1" 25 1/8" 3" 4 5/8" 117 3 3/4" 95 1 1/2" 38 304-A01-100 4" 102 1" 25 1/8" 3" 5 5/8" 143 4 1/4" 108 2" 51 304-A01-150 6" 152 1" 25 1/8" 3" 7 5/8" 194 5 1/4" 133 3" 76 304-A02-025 1" 25 1" 25 1/8" 3" 1 3/4" 44 2 3/4" 70 1/8" 3 304-A02-050 2" 51 1" 25 1/8" 3" 2 3/4" 70 3 1/4" 83 3/8" 10 Floor to Wall 304-A02-075 3" 76 1" 25 1/8" 3" 3 3/4" 95 3 3/4" 95 9/16" 14 304-A02-100 4" 102 1" 25 1/8" 3" 4 3/4" 121 4 1/4" 108 3/4" 19 304-A02-150 6" 152 1" 25 1/8" 3" 6 3/4" 171 5 1/4" 133 1 1/4" 31

312 Series - Recessed Mount A02 Floor/Wall (2" (51mm) system shown) A01 Floor/Floor S (2" (51mm) system shown) S H1 H1 ••Surface mount flanges conceal damaged flooring edges. W W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal US mm US mm US mm US mm US mm US mm 1 7 312-A01-050 2"312-A01-050 51 1" 25 * * 10 /8" 257 1 /8" 48 1" 25 Floor to Floor 312-A01-075 3" 75 1" 25 * * 131/8" 332 2 7/8" 73 11/2" 38

312-A01-100 4" 102 1" 25 * * 14 1/8" 358 2 7/8" 73 2" 51 Expansion Joint S yst e ms 312-A02-050 2" 51 1" 25 * * 6" 152 1 7/8" 48 3/8" 10 Floor to Wall 312-A02-075 3" 75 1" 25 * * 7" 178 1 7/8" 48 9/16" 14 312-A02-100 4" 102 1" 25 * * 9" 229 2 7/8" 73 3/4" 19 320 Series - New to Existing

A01 Floor/Floor (2" (51mm) system shown)

S H1

••Designed for retrofits, additions and renovations where blockout occurs on one side only. W ••Optional integral vapor barrier slides directly into frame for easy installation.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 320-A01-025 1" 25 1" 25 * * 4 5/8" 117 2 3/4" 70 1/8" 3 1/4" 6 320-A01-050 2" 51 1" 25 * * 6 1/8" 156 3 1/4" 83 3/8" 10 1/2" 13 Floor to Floor 320-A01-075 3" 76 1" 25 * * 7 5/8" 194 3 3/4" 95 9/16" 14 3/4" 19 320-A01-100 4" 102 1" 25 * * 9 1/8" 232 4 1/4" 108 3/4" 19 1" 25 320-A01-150 6" 152 1" 25 * * 12 1/8" 308 5 1/4" 133 1 1/4" 31 1 1/2" 38 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 19 Floor Systems - Centering Bar

400 Series systems meet Moderate to Heavy Duty loading scenarios such as warehouses, stadiums and auditoriums. The center bar and ••Highly modifiable systems can meet compression spring assembly correctly reposition pan after thermal any project's loads, movement and and seismic movement. finish requirements.

401 Series

A02 Floor/Wall (2" (51mm) system shown) ••Perfect for carpeted conditions. ••Cost effective, surface mounted S system with wide span capability. ••Throat-mounted bracket allows H1 S your project's wall base to continue uninterrupted over H1 the joint cover at floor/wall A01 Floor/Floor conditions. W (2" (51mm) system shown) W

W H1 H2 S Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Horizontal Vertical US mm US mm US mm US mm US mm US mm 401-A01-050 2" 51 1/8" 3 * * 8 1/2" 216 1" 25 1" 25 401-A01-100 4" 102 1/8" 3 * * 11 3/ " 298 2" 50 2" 50 Floor to Floor 4 401-A01-150 6" 152 3/16" 5 * * 14 1/2" 368 3" 75 3" 75 401-A01-200 8" 203 3/16" 5 * * 16 1/2" 419 4" 100 4" 100 401-A02-050 2" 50 1/8" 3 * * 5 1/4" 132 1" 25 1/2" 13 401-A02-100 4" 100 1/8" 3 * * 8" 202 2" 50 1” 25 Floor to Wall 401-A02-150 6" 150 3/16" 5 * * 10 1/4" 259 3" 75 1-1/2” 38 401-A02-200 8" 203 3/16" 5 * * 12 1/2" 419 4" 100 2” 51 Wider sizes available v

421 | 423 | 425 Series - Extra Wide

••Ideal for a wide range flooring conditions. 421 - A01 Floor/Floor ••Highly modifiable system – variable plate (14" (350mm) system shown) thicknesses allow system to meet many load scenarios. S ••421 series contains all aluminum components. H1 ••Stainless steel plate available on 423 system. ••Stainless steel plate and wings available on W 425 system.

W H1 H2 S B Movement +/- System Application (421,423,425) Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 421-A01-300 12" 300 1 5/8" 43 * * 28 7/8" 735 8 7/8" 225 6" 152 6" 152 5 1 Floor to Floor 421-A01-350 14" 350 1 /8" 43 * * 33 /8" 843 10" 254 7" 178 7" 178 421-A01-400 16" 400 1 7/8" 48 * * 38 5/8" 983 11 3/4" 298 8" 203 8" 203 421-A01-450 18" 450 1 7/8" 48 * * 42 3/4" 1087 12 3/4" 324 9" 229 9" 229 421-A02-300 12" 300 1 5/8" 43 * * 20 1/2" 520 8 7/8" 225 3" 76 1 1/2” 38 1 5 5 1 Floor to Wall 421-A02-350 14" 350 /8" 43 * * 23 /8" 599 10" 254 3 /2" 90 1 3/4” 44 421-A02-400 16" 400 1 7/8" 48 * * 27 3/8" 694 11 3/4" 298 4" 102 2” 51 421-A02-450 18" 450 1 7/8" 48 * * 30 3/8" 772 12 3/4" 324 4 1/2" 114 2 1/4” 57 Smaller and larger size configurations available

20 800.222.5556 | Installation Hotline: 866.ezinpro 426 | 427 | 428 Series - Extra Wide ••Full width cover plate creates a seamless transition over wide structural gaps. ••Can be installed with VCT for a narrow sightline (427 System). ••Can be installed with carpet or tile for a narrow sightline (428 System). ••Throat-mounted bracket allows your project's wall base to continue uninterrupted over the joint cover at floor/ wall conditions.

S S 428 - A01 Floor/Floor for Carpet S H2 S (14" (350mm) system shown) H2 H1H1

WW

427 - A01 Floor/Floor for VCT SS H2H2 SS (14" (350mm) system shown) H1H1

WW

426 - A01 Floor/Floor S H1 (14" (350mm) system shown) H1

W

426 - A02 Floor/Wall S (14" (350mm) system shown)

H1H1

Expansion Joint S yst e ms W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 426-A01-300 12" 300 1 5/8" 43 * * 28 1/8" 735 8 1/2" 216 6" 152 6" 152 426-A01-350 14" 350 1 5/8" 43 * * 33 1/8" 843 10" 254 7" 178 7" 178 426-A01-400 16" 400 1 7/8" 48 * * 38 5/8" 983 11 3/4" 298 8" 203 8" 203 426-A01-450 18" 450 1 7/8" 48 * * 42 3/4" 1087 12 3/4" 330 9" 229 9" 229 427-A01-300 12" 300 1 5/8" 43 1/8" 3 3 3/4" 95 10" 254 6" 152 6" 152 1 5 1 3 1 Floor to Floor 427-A01-350 14" 350 /8" 43 /8" 3 3 /4" 95 10 /2" 267 7" 178 7" 178 427-A01-400 16" 400 1 7/8" 48 1/8" 3 3 3/4" 95 12 1/8" 308 8" 203 8" 203 427-A01-450 18" 450 1 7/8" 48 1/8" 3 3 3/4" 95 13 1/8" 333 9" 229 9" 229 428-A01-300 12" 300 1 5/8" 43 3/8" 10 3 3/4" 95 10" 254 6" 152 6" 152 428-A01-350 14" 350 1 5/8" 43 3/8" 10 3 3/4" 95 11 1/8" 283 7" 178 7" 178 428-A01-400 16" 400 1 7/8" 48 3/8" 10 3 3/4" 95 12 3/4" 325 8" 203 8" 203 428-A01-450 18" 450 1 7/8" 48 3/8" 10 3 3/4" 95 13 3/4" 351 9" 229 9" 229 426-A02-300 12" 300 1 5/8" 43 * * 20 1/2" 520 8 7/8" 216 3" 76 3" 76 426-A02-350 14" 350 1 5/8" 43 * * 23 5/8" 599 10" 254 3 1/2" 90 3 1/2" 90 426-A02-400 16" 400 1 7/8" 48 * * 27 3/8" 694 11 3/4" 298 4" 102 4" 102 426-A02-450 18" 450 1 7/8" 48 * * 30 3/8" 772 12 3/4" 303 4 1/2" 114 4 1/2" 114 427-A02-300 12" 300 1 5/8" 43 1/8" 3 1 7/8" 47 10" 254 3" 76 3" 76 427-A02-350 14" 350 1 5/8" 43 1/8" 3 1 7/8" 47 10 1/2" 267 3 1/2" 90 3 1/2" 90 Floor to Wall 427-A02-400 16" 400 1 7/8" 48 1/8" 3 1 7/8" 47 12 1/8" 308 4" 102 4" 102 427-A02-450 18" 450 1 7/8" 48 1/8" 3 1 7/8" 47 13 1/8" 333 4 1/2" 114 4 1/2" 114 428-A02-300 12" 300 1 5/8" 43 3/8" 10 1 7/8" 47 10" 254 3" 76 3" 76 428-A02-350 14" 350 1 5/8" 43 3/8" 10 1 7/8" 47 11 1/8" 283 3 1/2" 90 3 1/2" 90 428-A02-400 16" 400 1 7/8" 48 3/8" 10 1 7/8" 47 12 3/4" 325 4" 102 4" 102 428-A02-450 18" 450 1 7/8" 48 3/8" 10 1 7/8" 47 13 3/4" 351 4 1/2" 114 4 1/2" 114 Smaller and larger size configurations available inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 21 Floor Systems - Centering Bar

••Mill finish standard. 400 Series systems meet Moderate loading scenarios such as medical office buildings, hospital corridors and school assembly spaces. % of MOVEMENT VAPOR BARRIER The center bar and compression spring assembly ±50% optional correctly reposition pan after seismic movement. JOINT WIDTH fire rated 1" (25mm) – 8" (200mm) optional

430 Recessed Mount - Hidden Fastener 432 Recessed Mount - Exposed Fastener

Industry unique, tapered center plate design creates an extremely smooth transition, ideal for rolling loads.

Ideal for carpet, vinyl, ceramic tile and other floor finishes. Flooring may be inserted under cover plate for reduced sightline.

430-A02 Floor/Wall Hidden Fastener Model 430-A01 Floor/Floor Exposed Fastener Model 432-A01 Floor/Floor (2" (51mm) system shown) (2" (51mm) system shown) (2" (51mm) system shown) SS 7 S S 1 8 ” [49mm] H1 H1 H1H1

WW W W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 430-A01-025 1" 25 1 1/2" 38 * * 4 1/8" 105 3" 76 1/2" 13 1/4" 6 430-A01-050 2" 51 1 1/2" 38 * * 5 1/2" 140 3 1/4" 83 1" 25 1/2" 13 430-A01-075 3" 76 1 1/2" 38 * * 7 3/4" 197 4" 102 1 1/2" 38 3/4" 19 430-A01-100 4" 102 1 1/2" 38 * * 8 3/4" 222 4" 102 2" 51 1" 25 430-A01-150 6" 152 1 1/2" 38 * * 13 1/2" 343 5 1/4" 133 3" 76 1 1/2" 38 1 Floor to Floor 430-A01-200 8" 203 1 /2" 38 * * 18" 457 7" 178 4" 102 2" 51 432-A01-025 1" 25 1 1/2" 38 * * 4 1/8" 105 3" 76 1/2" 13 1/4" 6 432-A01-050 2" 51 1 1/2" 38 * * 5 1/2" 140 3 1/4" 83 1" 25 1/2" 13 432-A01-075 3" 76 1 1/2" 38 * * 7 3/4" 197 4" 102 1 1/2" 38 3/4" 19 432-A01-100 4" 102 1 1/2" 38 * * 8 3/4" 222 4" 102 2" 51 1" 25 432-A01-150 6" 152 1 1/2" 38 * * 13 1/2" 343 5 1/4" 133 3" 76 1 1/2" 38 432-A01-200 8" 203 1 1/2" 38 * * 18" 457 7" 178 4" 102 2" 51 430-A02-025 1" 25 1 1/2" 38 * * 2 1/2" 64 3" 76 1/4" 6 1/4" 6 430-A02-050 2" 51 1 1/2" 38 * * 3 3/4" 95 3 1/4" 83 1/2" 13 1/2" 13 1 3 3 3 Floor to Wall 430-A02-075 3" 76 1 /2" 38 * * 5 /8" 137 4" 102 /4" 19 /4" 19 430-A02-100 4" 102 1 1/2" 38 * * 6 3/8" 162 4" 102 1" 25 1" 25 430-A02-150 6" 152 1 1/2" 38 * * 9 3/4" 248 5 1/4" 133 1 1/2" 38 1 1/2" 38 430-A02-200 8" 203 1 1/2" 38 * * 13" 330 7" 178 2" 51 2" 51

22 800.222.5556 | Installation Hotline: 866.ezinpro 441 Series - Recessed Mount S 441-A02 Floor/Wall (2" (51mm) system shown)

H1

441-A01 Floor/Floor W (2" (51mm) system shown) S ••Flooring may be inserted under plate for H1 reduced sightline. ••Exposed fastener makes maintenance easier. W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 441-A01-050 2" 50 1" 25 * * 8 1/2" 216 3 1/4" 83 1" 25 1" 25 Floor to Floor 441-A01-100 4" 100 1" 25 * * 11 3/4" 298 3 1/4" 83 2" 50 2" 50 441-A01-150 6" 150 1" 25 * * 14 1/2" 368 3 1/4" 83 3" 75 3" 75 441-A02-050 2" 50 1" 25 * * 5 1/4" 132 3 1/4" 83 1" 25 1/2" 13 Floor to Wall 441-A02-100 4" 100 1" 25 * * 8" 202 3 1/4" 83 2" 50 1” 25 441-A02-150 6" 150 1" 25 * * 10 1/4" 259 3 1/4" 83 3" 75 1-1/2” 38 Other sizes and finishes available

461 Series - New to Existing 461-A01 Floor/Floor (4" (100mm) system shown) ••Designed for retrofits, additions and renovations where S blockout occurs on one side only. H2 H1 ••Tapered center plate design creates smooth transition. ••Meets ADA requirements. W

471 Series - Surface Mount

471-A01 Floor/Floor Expansion Joint S yst e ms (4" (100mm) system shown) S H2

W S 471-A02 Floor/Wall S 7 ••Surface mount ideal for retrofits, additions and renovations. (4" (100mm) system shown) 1 8 ” [48MM] ••Flooring may be inserted under plate for reduced sightline. ••Exposed fastener makes maintenance easier. H1 H1 WW ••Tapered center plate design creates smooth transition.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 461-A01-075 3" 76 1 1/2" 38 1/4" 6 9 1/4" 235 4" 102 1 1/2" 38 3/4" 19 461-A01-100 4" 102 1 1/2" 38 1/4" 6 10 1/4" 260 4" 102 2" 51 1" 25 461-A01-150 6" 152 1 1/2" 38 5/16" 8 15 1/4" 387 5 1/4" 133 3" 76 1 1/2" 38 461-A01-200 8" 203 1 1/ " 38 5/ " 8 19 5/ " 498 7" 178 4" 102 2" 51 Floor to Floor 2 16 8 471-A01-075 3" 76 * * 1/4" 6 10 1/2" 267 * * 1 1/2" 38 3/4" 19 471-A01-100 4" 102 * * 1/4" 6 11 7/8" 302 * * 2" 51 1" 25 471-A01-150 6" 152 * * 5/16" 8 16 7/8" 430 * * 3" 76 1 1/2" 38 471-A01-200 8" 203 * * 5/16" 8 21 3/8" 543 * * 4" 102 2" 51 471-A02-075 3" 76 * * 1/4" 6 6 3/4" 171 * * 3/4" 19 3/4" 19 471-A02-100 4" 102 * * 1/ " 6 7 7/ " 200 * * 1" 25 1" 25 Floor to Wall 4 8 471-A02-150 6" 152 * * 5/16" 8 11 1/2" 292 * * 1 1/2" 38 1 1/2" 38 471-A02-200 8" 203 * * 5/16" 8 14 3/4" 375 * * 2" 51 2" 51 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 23 Floor Systems - Heavy Duty

700 Series systems meet Heavy Duty loading % of MOVEMENT VAPOR BARRIER scenarios in many environments such as ±50% optional open structures, stadium venues, parking structures, airports and warehouses. JOINT WIDTH fire rated 1" (25mm) – 12" (300mm) optional

721 | 723 | 725 Series

••Highly modifiable system capable of meeting many loading scenarios. ••Heavy Duty bearing system. ••Engineered for pneumatic and solid tires. ••Stainless steel plate available on 723 system. ••Stainless steel plate and wings available on 725 system.

721-A01 Floor/Floor (4" (100mm) system shown) S H1H1

W

723-A01 Floor/Floor 725-A01 Floor/Floor (4" (100mm) system shown) (4" (100mm) system shown) S S Aluminum Stainless Steel Aluminum Stainless Steel S Stainless Steel Stainless Steel Wing Plate Coverplate Wing Plate Wing Plate Coverplate Wing Plate

H1H1 H1H1

W W

W H1 S B Movement +/-

723-A01-100 System 725-A01-100 Application (721,723,725) Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 721-A01-050 2" 51 1 5/8" 40 8 1/2" 216 3 3/4" 95 1"" 25 1" 25 721-A01-100 4" 102 1 5/8" 40 12 1/2" 318 4 3/4" 121 2" 51 2" 51 Floor to 721-A01-150 6" 152 1 5/8" 40 16 1/2" 406 5 3/4"" 146 3" 76 3" 76 Floor 721-A01-200 8" 203 1 5/8" 40 20 1/2" 502 6 3/4" 171 4" 102 4" 102 721-A01-300 12" 305 1 5/8" 40 28 1/2" 705 8 3/4" 222 6" 152 6" 152 721-A02-050 2" 51 1 5/8" 40 5 1/4" 133 3 3/4" 95 1/2" 13 1/2" 13 721-A02-100 4" 102 1 5/8" 40 8 1/4" 210 4 3/4" 121 1" 25 1" 25 Floor to Wall 721-A02-150 6" 152 1 5/8" 40 11 1/4" 286 5 3/4" 146 1 1/2" 38 1 1/2" 38 721-A02-200 8" 203 1 5/8" 40 14 1/4" 362 6 3/4" 171 2" 51 2" 51 721-A02-300 12" 305 1 5/8" 40 20 1/4" 515 8 3/4" 222 3" 76 3" 76 Larger sizes available

24 800.222.5556 | Installation Hotline: 866.ezinpro 741-A01 Floor/Floor 741 Series (4" (100mm) system shown)

S

H1

••Cost-effective option for a high load bearing system. ••Engineered for pneumatic and solid tires. W ••Stainless steel plate available. ••System designed to be installed over finished flooring.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 741-A01-050 2" 50 1" 25 * * 8 1/2" 216 3 1/4" 83 1" 25 1" 25 Floor to Floor 741-A01-100 4" 100 1" 25 * * 11 3/4" 298 3 1/4" 83 2" 50 2" 50 741-A01-150 6" 150 1" 25 * * 14 1/2" 368 3 1/4" 83 3" 75 3" 75 Other sizes and finishes available

757 | 767 Series

757-A01 Floor/Floor (8" (200mm) system shown) S

H1H1

••Flush, constant leveling, low profile design Optional vapor barrier shown Expansion Joint S yst e ms W allows for a smooth transition when W traversing the joint system. ••Optional integral vapor barrier slides directly 767-A01 Floor/Floor into frame for easy installation. (8" (200mm) system shown) ••767 series allows for additional hardware S anchorage points in environments with high vibration or vehicular loading. H1 ••Utilizes elastomeric concrete system nosing to reduce vibrations imposed on the system resulting in extended-life of the components. Optional vapor barrier available W ••Mill finish standard.

W H1 H2 S B Movement +/- System Application (757, 767) Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 757-A01-100 4" 100 2" 51 * * 13 1/2" 222 6 5/8" 102 2" 51 3/4" 152 Floor to Floor 757-A01-150 6" 150 2" 51 * * 15 1/2" 394 6 5/8" 206 3" 76 1 1/2" 178 757-A01-200 8" 200 2" 51 * * 17 1/2" 445 6 5/8" 206 4" 102 2" 203

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 25 Floor Systems - Heavy Duty Seismic

787 Series

Industry unique, low profile design reduces the lateral impact (shear forces) encountered with repeated vehicular traffic.

Tapered plate and frames provide a seamless design that constantly levels itself and maintains Heavy Duty design uses a thick, a flush condition. high strength centering bar and spring assembly to resist vibrations, Serrated cover plate for extending joint lifecycle. added slip resistance.

••Seismic capable system designed to meet the needs of an open % of MOVEMENT VAPOR BARRIER structure and vehicular loading scenarios. 25%-50% optional ••1" [32mm] frame depth ensures no interference in rebar/cabling structures with concrete decks. JOINT WIDTH fire rated 4"-12" optional ••Integral high durometer seal acts as a noise dampener and deters water from slipping beneath plate. ••Mill finish standard.

787-A01 Floor/Floor 787-A02 Floor/Wall S (4" (100mm) system shown) (4" (100mm) system shown) S

H1 H1

W W

W H S B Movement +/- Application System Joint Width Frame Height Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 787-A01-100 4" 100 1" 25 13 1/2" 342 6 " 152 2" 51 1" 25 787-A01-150 6" 150 1" 25 16 1/2" 419 6 1/2" 165 3" 76 1 1/2" 38 Floor to Floor 787-A01-200 8" 200 1" 25 18 1/2" 470 6 1/2" 165 4" 102 2" 51 787-A01-250 10" 250 1" 25 24 1/2" 622 8 1/2" 216 5" 127 2 1/2" 64 787-A01-300 12" 300 1" 25 26 1/2" 673 8 1/2" 216 6" 152 3" 76 787-A02-100 4" 100 1" 25 8 3/4" 222 6" 152 1" 25 1" 25 787-A02-150 6" 150 1" 25 11 1/4" 286 6 1/2" 165 1 1/2" 76 1 1/2" 38 Floor to Wall 787-A02-200 8" 200 1" 25 13 1/4" 337 6 1/2" 165 2" 102 2" 51 787-A02-250 10" 250 1" 25 17 1/4" 438 8 1/2" 216 2 1/2" 127 2 1/2" 64 787-A02-300 12" 300 1" 25 19 1/4" 489 8 1/2" 216 3" 152 3" 76 Different configurations and larger joint sizes available

26 800.222.5556 | Installation Hotline: 866.ezinpro Floor Systems - Standard

••Mill finish standard. The 800 Series is our most cost effective product line that is suitable for many joint sizes in a variety of applications.

801 Series

A01 Floor/Floor A02 Floor/Wall (1" (25mm) system shown) (2" (51mm) system shown) S S H1

W ••Beveled edges provide pedestrian safety. H1 ••Pre-drilled, counter-sunk holes for easy installation. W ••Available in stainless steel and other custom finishes.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 801-A01-025 1" 25 1/ " 3 * * 4 1/ " 105 * * 1/ " 13 * * Floor to Floor 8 8 2 801-A01-050 2" 51 1/8" 3 * * 5 5/8" 143 * * 1" 25 * * 801-A02-025 1" 25 1/ " 3 * * 1 1/ " 38 * * 1/ " 13 * * Floor to Wall 8 2 2 801-A02-050 2" 51 1/8" 3 * * 3" 76 * * 1" 25 * * Additional sizes and finishes available

804 Series Expansion Joint S yst e ms

A01 Floor/Floor A02 Floor/Wall (1" (25mm) system shown) (1" (25mm) system shown) S H1

••Spring clip design for easy on-site installation. W ••A07 Condition offers finish options on page 7. ••Designed to be installed over finished flooring.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 804-A01-025 1" 25 1/8" 4 * * 3" 76 * * 1/4" 6 1/8" 3 Floor to Floor 804-A01-038 1 1/2" 38 1/8" 4 * * 3" 76 * * 3/8" 10 1/8" 3 804-A01-050 2" 51 1/8" 4 * * 4 1/2" 114 * * 1/2" 13 1/8" 3 804-A02-025 1" 25 1/8" 4 * * 2" 50 * * 1/4" 6 1/8" 3 Floor to Wall 804-A02-038 1 1/2" 38 1/8" 4 * * 2" 50 * * 3/8" 10 1/8" 3 804-A02-050 2" 51 1/8" 4 * * 3 1/4" 83 * * 1/2" 13 1/8" 3 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 27 Floor Systems - Standard Cover Plate

806 Series

Pre-drilled, counter-sunk holes for easy installation Designed for uneven slab conditions and vertical Designed to be installed shear conditions. over finished flooring.

A02 Floor/Wall (2" (51mm) system shown) A01 Floor/Floor S (2" (51mm) system shown) ••Moderate loading capabilities. S H1 ••Unlimited lateral shear movement. ••Mill finish standard. H1 W W

W H1 H2 S B1 Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 806-A01-050 2" 51 1/4" 6 * * 7" 178 * * 1" 25 * * 806-A01-100 4" 102 1/4" 6 * * 10 1/2" 267 * * 2" 51 * * Floor to Floor 806-A01-150 6" 152 1/4" 6 * * 13" 330 * * 3" 76 * * 806-A01-200 8" 203 5/16" 8 * * 17" 432 * * 4" 102 * * 806-A01-300 12" 305 5/16" 8 * * 23" 584 * * 6" 152 * * 806-A02-050 2" 51 1/4" 6 * * 4" 102 * * 1" 25 * * 806-A02-100 4" 102 1/4" 6 * * 7 1/2" 191 * * 2" 51 * * Floor to Wall 806-A02-150 6" 152 1/4" 6 * * 10" 254 * * 3" 76 * * 806-A02-200 8" 203 5/16" 8 * * 13" 330 * * 4" 102 * * 806-A02-300 12" 305 5/16" 8 * * 19" 483 * * 6" 152 * *

28 800.222.5556 | Installation Hotline: 866.ezinpro 802 | 807 Series

A01 Floor/Floor H1 S H2 (2" (51mm) system shown)

W A02 Floor/Floor (2" (51mm) system shown) S 5 S 1 8 “ [41mm] ••Design accommodates various flooring H2H2 thicknesses and finishes from carpet to VCT. ••Overlap design reduces sightline to only 2". ••Mill finish standard. WW

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 802-A01-050/3 2" 51 1/8" 3 1/8" 4 2" 51 * * 1/2" 13 * * 802-A01-050/6 2" 51 1/8" 3 1/4" 6 2" 51 * * 1/2" 13 * * 802-A01-050/10 2" 51 1/8" 3 3/8" 10 2" 51 * * 1/2" 13 * * Floor to Floor 807-A01-050 2" 50 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 807-A01-075 3" 75 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 807-A01-100 4" 100 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 807-A01-150 6" 150 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 807-A02-050 2" 50 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 807-A02-075 3" 75 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 Floor to Wall 807-A02-100 4" 100 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25 807-A02-150 6" 150 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25

808 Series

A01 Floor/Floor (2" (51mm) system shown) S

H1

••Beveled edges and serrated plates provide traction for pedestrian safety.

••Pre-drilled, counter-sunk holes for easy installation. Expansion Joint S yst e ms W ••Designed to be installed over finished flooring. ••Mill finish standard.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal US mm US mm US mm US mm US mm US mm 808-A01-025 1" 25 1/4" 6 * * 6" 152 * * 1/2" 13 808-A01-050 2" 51 1/4" 6 * * 6" 152 * * 1" 25 Floor to Floor 808-A01-075 3" 76 1/4" 6 * * 10" 254 * * 1 1/2" 38 808-A01-100 4" 102 1/4" 6 * * 10" 254 * * 2" 51

University of Wisconsin Platteville, Platteville, WI 300 Series | 811 Series

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 29 Floor Systems - Narrow Sightline and Pan Systems

Virtually eliminates wide sightlines. Configurations % of MOVEMENT VAPOR BARRIER allow for use in new construction or renovations. ±50% - 100% optional These multifunctional designs provide alignment for JOINT WIDTH fire rated floor and corner conditions. 2" (25mm) – 12" (300mm) optional

316 Series Single Sightline

A01 Floor/Floor S (2" (51mm) system shown) H1

W

••Reduces 2-4" (102mm) gaps to only a 1" (25mm) single sightline. A02 Floor/Wall (2" (51mm) system shown) S ••Multifunctional design provides for alignment of system sightlines at continuous Floor-to-Floor and Floor-to-Wall conditions. ••Specifically designed for continuous flooring types such as carpeting or vinyl sheet. ••Rated for high pedestrian load. H1H1 2" W B [50mm] min. blockout

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 316-A01-050 2" 51 2" 51 1" 25 4 1/2" 114 1" 25 1" 25 Floor to Floor 316-A01-075 3" 76 2" 51 1" 25 4 1/2" 114 1 1/2" 38 1 1/2" 38 316-A01-100 4" 102 2" 51 1" 25 4 1/2 114 1 1/2" 38 1 1/2" 38 316-A02-050 2" 51 2" 51 1" 25 4 1/2" 114 1" 25 1" 25 Floor to Wall 316-A02-075 3" 76 2" 51 1" 25 4 1/2" 114 1 1/2" 38 1 1/2" 38 316-A02-100 4" 102 2" 51 1" 25 4 1/2 114 1 1/2" 38 1 1/2" 38

30 800.222.5556 | Installation Hotline: 866.ezinpro 501 Series - "Pop-up" Pan System

Central pan rides up the frame under seismic movement then returns to position to maintain egress routes.

501-A01-100-POPPED

A01 Floor/Floor ••The combined use of centerbars and compression (4" (100mm) system shown) S H2 S spring components correctly reposition the pan after seismic movement. H1 ••The 501 system can reduce expansion joints of widths up to 8" (203mm) down to just two 1/2" (13mm) reveals. ••Ideal for carpeted areas where slim sightlines on larger joints are required for aesthetic reasons. ••Floor-to-Floor applications only. W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 501-A01-050 2" 51 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 2" 6 501-A01-075 3" 76 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 3" 13 Floor to Floor 501-A01-100 4" 102 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 4" 19 501-A01-150 6" 152 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 6" 25 501-A01-200 8" 203 2" 51 1 1/2" 38 1" 25 5" 127 7 1/2" 191 8" 38

502 Series - "Hinged" Pan System

A01 Floor/Floor (4" (100mm) system shown) Hinged pan rides up the canted frame under S S seismic movement then returns to position to maintain egress routes. H1

H2H2 Expansion Joint S yst e ms

Ideal for floor finishes with increased B WW depths such as marble, granite, A02 Floor/Wall S limestone and paver systems. (4" (100mm) system shown) ••System provides for unlimited S lateral movement. H1 ••Pan profile provides a vertical surface to abut tile against, eliminating the H need to bevel flooring edges. ••Reveals align for Floor-to-Floor and Floor-to-Wall applications. B W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 502-A01-050 2" 51 2" 51 5 1/2" 139 1" 25 9 3/8" 238 1" 25 1" 25 502-A01-100 4" 102 2" 51 5 1/ " 139 1" 25 7 3/8" 187 2" 51 2" 51 Floor to Floor 2 502-A01-150 6" 152 2" 51 5 1/2" 139 1" 25 8 3/8" 222 3" 76 3" 76 502-A01-200 8" 203 2" 51 5 1/2" 139 1" 25 9 3/8" 238 4" 102 4" 102 502-A02-050 2" 51 2" 51 5 1/2" 139 1" 25 9 3/8" 238 1" 25 1" 25 502-A02-100 4" 102 2" 51 5 1/ " 139 1" 25 7 3/8" 187 2" 51 2" 51 Floor to Wall 2 502-A02-150 6" 152 2" 51 5 1/2" 139 1" 25 8 3/8" 222 3" 76 3" 76 502-A02-200 8" 203 2" 51 5 1/2" 139 1" 25 9 3/8" 238 4" 102 4" 102 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 31 Project Profile: The Exploratorium® at Pier 15 San Francisco, California

Architect: Esherick Homey Dodge & Davis San Francisco, California

General Contractor: Nibbi Brothers San Francisco, California

Expansion Joint Contractor: Expansion Specialties, Inc. Henderson, Nevada

The Project The $220 million Exploratorium is located in the heart of San Francisco’s waterfront. Hands-on exhibits explore biology, physics, listening, cognition, visual perception, social behavior and the environment.

The Challenge The Solution After breaking ground in October 2010, the first phase JointMaster® provided the entire expansion joint and of this project included refurbishing and seismically fire barrier package for the Exploratorium project. upgrading the historic Pier 15 – spanning the length of Almost 1,500 linear feet of interior and exterior almost three football fields over the water. Engineers seismic expansion joints are used throughout the drove piles underneath the bay to replace, repair and/ building. Joint widths varied from 8" to as wide as 27". or seismically upgrade, hundreds of dilapidated pilings Of that, nearly 95 percent of the joint systems were and the substructure, some which date to the early custom designed and built, including several joints 20th century. incorporating 3/8" thick stainless steel diamond plate. The built space of 330,000 square feet includes Because the Exploratorium is built over the water, quintessential Exploratorium exhibits in four galleries; designers specified Kynar® coatings on many of the joint space for professional teacher training, after-school systems to fight salt-water effects. In addition, waterproof programs, educational camps and lifelong learning; a fire barrier was incorporated where specified. theater; the Exploratorium store; and a café. And in the spirit and style of the Exploratorium, there is a display dedicated to the expansion joints used, helping visitors and students understand a building’s constant battle with Mother Nature, and how expansion joints help a building withstand thermal and seismic movement.

32 800.222.5556 | Installation Hotline: 866.ezinpro Wall and Ceiling Systems

JointMaster® offers a comprehensive line of Wall and Ceiling Expansion Joint Systems with recessed and drywall options for both thermal and seismic conditions. Expansion Joint S yst e ms

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 33 Wall and Ceiling - Drywall Finishes

••Standard and custom seal colors available, see pages 66-67.

% of MOVEMENT VAPOR BARRIER Cost effective systems with simple installations ±25% optional assist in controlling project budgets. JOINT WIDTH fire rated 1" (25mm) – 3" (76mm) optional

112 Series - Recessed Mount for 5/8" (16mm) Drywall

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) (2" (51mm) system shown) ••Snap-in frame accepts 5/8" H1 (16mm) drywall. No finish required, saving on site installation costs. W ••Clear anodized aluminum S for a decorative finish. W S ••Available finish options, see page 66-67. H1

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 112-A07-025 1" 25 5/8" 16 * * 2" 51 * * 1/4" 6 1/4" 6 Wall to Wall 112-A07-038 1 1/2" 38 5/8" 16 * * 2 7/16" 62 * * 3/8" 10 3/8" 10 Ceiling to Ceiling 112-A07-050 2" 51 5/8" 16 * * 2 7/8" 73 * * 1/2" 13 1/2" 13 112-A07-075 3" 76 5/8" 16 * * 4" 102 * * 3/4" 19 3/4" 19 112-A09-025 1" 25 5/8" 16 * * 1 1/2" 38 * * 1/4" 6 1/4" 6 Wall to Corner 112-A09-038 1 1/2" 38 5/8" 16 * * 1 15/16" 49 * * 3/8" 10 3/8" 10 Wall to Ceiling 112-A09-050 2" 51 5/8" 16 * * 2 3/8" 60 * * 1/2" 13 1/2" 13 112-A09-075 3" 76 5/8" 16 * * 3 3/8" 86 * * 3/4" 19 3/4" 19 - Surface Mount

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) (2" (51mm) system shown)

W S W S

••Frame allows for finish with joint compound or wall covering. ••Dual durometer seal provides secure fit and optimal flexibility. ••Sightline reduced to width of flexible seals.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 113-A07-025 1" 25 * * * * 1" 25 * * 1/4" 6 1/4" 6 Wall to Wall 113-A07-038 1 1/2" 38 * * * * 1 1/2" 36 * * 3/8" 10 3/8" 10 Ceiling to Ceiling 113-A07-050 2" 51 * * * * 2" 47 * * 1/2" 13 1/2" 13 113-A07-075 3" 76 * * * * 3" 76 * * 3/4" 19 3/4" 19 113-A09-025 1" 25 * * * * 1" 25 * * 1/4" 6 1/4" 6 Wall to Corner 113-A09-038 1 1/2" 38 * * * * 1 1/2" 36 * * 3/8" 10 3/8" 10 Wall to Ceiling 113-A09-050 2" 51 * * * * 2" 47 * * 1/2" 13 1/2" 13 113-A09-075 3" 76 * * * * 3" 73 * * 3/4" 19 3/4" 19

34 800.222.5556 | Installation Hotline: 866.ezinpro 101 Recessed Mount

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) (2" (51mm) system shown) H2 H2

W S

••Recessed mount frame for minimal sightline. WW S ••Dual durometer seal provides secure fit and optimal flexibility. ••Adaptable to any 5/8" (16mm) wall and ceiling finish, including drywall, plaster and tile. ••Snap-fit design allows for easy on-site assembly.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 101-A07-025 1" 25 3/4" 19 5/8" 16 1" 25 * * 1/4" 6 1/4" 6 Wall to Wall 101-A07-038 1 1/2" 38 3/4" 19 5/8" 16 1 7/16" 36 * * 3/8" 10 3/8" 10 Ceiling to Ceiling 101-A07-050 2" 51 3/4" 19 5/8" 16 1 7/8" 47 * * 1/2" 13 1/2" 13 101-A07-075 3" 76 3/4" 19 5/8" 16 2 7/8" 73 * * 3/4" 19 3/4" 19 101-A09-025 1" 25 3/4" 19 5/8" 16 1" 25 * * 1/4" 6 1/4" 6 Wall to Corner 101-A09-038 1 1/2" 38 3/4" 19 5/8" 16 1 7/16" 36 * * 3/8" 10 3/8" 10 Wall to Ceiling 101-A09-050 2" 51 3/4" 19 5/8" 16 1 7/8" 47 * * 1/2" 13 1/2" 13 101-A09-075 3" 76 3/4" 19 5/8" 16 2 7/8" 73 * * 3/4" 19 3/4" 19

821 Acoustical Ceiling

V24 Ceiling/Ceiling (2" (51mm) system shown) Expansion Joint S yst e ms

S

V23 Ceiling/Wall (2" (51mm) system shown)

••Pop-rivet design allows for easy on-site assembly. ••Co-extruded pleated vinyl allows fluid movement. ••Bright white seal only. S

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 821-V24-025 1" 25 * * * * 1" 25 * * 1/2" 13 1/2" 13 Wall to Wall 821-V24-050 2" 51 * * * * 2" 51 * * 1" 25 1/2" 13 Ceiling to Ceiling 821-V23-025 1" 25 * * * * 1" 25 * * 1/2" 13 1/2" 13 821-V23-050 2" 51 * * * * 2" 51 * * 1" 25 1/2" 13 Standard color bright white

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 35 Wall and Ceiling - Drywall Acoustical, Flush Mount

••Standard and custom seal colors available, see pages 66-67. Pleated Santoprene® seal design allows for fluid, % of MOVEMENT VAPOR BARRIER thermal and seismic movement during joint ±50% - 100% optional (114) expansion, contraction, lateral and out-of- plane movement. JOINT WIDTH fire rated 2" (50mm) – 6" (150mm) optional (144 & 611)

114 Series - Drywall

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (3" (75mm) system shown) (2" (51mm) system shown) W

••Frame allows for finish with joint compound or wall covering to W S minimize sightline.

S

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 114-A07-050 2" 51 * * * * 2 1/8" 54 * * 1" 25 1" 25 Wall to Wall 114-A07-075 3" 76 * * * * 3 1/16" 78 * * 1 1/2" 38 1 1/2" 38 Ceiling to Ceiling 114-A07-100 4" 102 * * * * 4 1/8" 105 * * 2" 51 2" 51 114-A07-150 6" 152 * * * * 6 1/8" 156 * * 3" 76 3" 76 114-A09-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25 Wall to Corner 114-A09-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Wall to Ceiling 114-A09-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51 114-A09-150 6" 152 * * * * 6" 152 * * 3" 76 3" 76

115 Series - Acoustical Ceiling

A24 Ceiling/Ceiling A18 Wall/Ceiling (2" (51mm) system shown) (2" (51mm) system shown)

••Frame pop rivets to T-Bar profile in suspended ceiling system. W W ••Seal design allows for seismic movement.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm Wall to Wall 115-A24-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25 115-A24-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Ceiling to Ceiling 115-A24-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51 Wall to Corner 115-A18-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25 115-A18-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Wall to Ceiling 115-A18-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51

36 800.222.5556 | Installation Hotline: 866.ezinpro 611 Series - Flush Mount A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) (4" (102mm) system shown)

••Sightline reduced to width of flexible seal. ••Seals available in standard W S and custom colors see W S pages 66-67.

H1 H1

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 611-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25 Wall to Wall 611-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Ceiling to Ceiling 611-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51 611-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76 611-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25 Wall to Corner 611-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Wall to Ceiling 611-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51 611-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

612 Series - Flush Mount A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (12" (300mm) system shown) (10" (250mm) system shown)

W S W S Expansion Joint S yst e ms ••Industry-unique Santoprene® seal design allows for fluid seismic movement during joint expansion and contraction. ••Field heat-weldable Santoprene seals for weather tight seams and crisp transitions. ••Seal walls are among the thickest in the industry allowing our product to be used in soffits and corridor ceilings with no sagging. H1 H1

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 612-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102 612-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127 Wall to Wall 612-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152 612-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229 612-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305 612-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102 612-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127 Wall to Corner 612-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152 612-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229 612-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305 Larger sizes available inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 37 Wall and Ceiling - Drywall Flush Mount

Accommodates large joint widths with narrow ••Center bar and compression spring assembly correctly reposition sightlines for minimal aesthetic interruption. pan after seismic movement. ••Seal barbs provide secure engagement in frame, making installation easier. % of MOVEMENT VAPOR BARRIER ••Face of seal resists sagging and remains flat in ceiling conditions. ±50% optional ••Field heat-weldable Santoprene® seals for weather tight transitions. JOINT WIDTH fire rated •• Standard and custom seal colors available, see pages 66-67. 8" (200mm)-24" (600m) optional

221 Series - Aluminum Plate A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling H1 (8" (200mm) system shown) (8" (200mm) system shown)

S

W H1 1 3/4” S [44mm] S W ••Intended for use on smaller joint sizes where durability is required. ••Easy installation and maintenance. ••Anodized finish standard.

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 221-A07-050 2" 51 5/8" 16 4 7/8" 124 1 1/2" 13 1” 25 1” 25 221-A07-100 4" 102 5/8" 16 9 3/8" 238 2 3/4" 70 2” 51 2” 51 221-A07-150 6" 152 5/8" 16 11 3/8" 289 2 3/4" 70 3” 75 3” 75 Wall to Wall 221-A07-200 8" 200 5/8" 16 18" 457 4 1/2" 114 4” 102 4” 102 221-A07-250 10" 250 5/8" 16 21" 533 4 1/2" 114 5” 125 5” 125 221-A07-300 12" 300 5/8" 16 24" 609 4 1/2" 114 6” 152 6” 152 221-A09-050 2" 51 5/8" 16 3 1/2" 89 1 1/2" 13 1/4" 6 1/4" 6 221-A09-100 4" 102 5/8" 16 6 5/8" 168 2 3/4" 70 1/2" 13 1/2" 13 221-A09-150 6" 152 5/8" 16 8 5/8" 219 2 3/4" 70 1/2" 13 1/2" 13 Wall to Corner 221-A09-200 8" 200 5/8" 16 13" 330 4 1/2" 114 2 51 2 51 221-A09-250 10" 250 5/8" 16 15 1/2" 394 4 1/2" 114 2 1/2" 64 2 1/2" 64 221-A09-300 12" 300 5/8" 16 18" 457 4 1/2" 114 3 76 3 76 Larger sizes available - Custom joints up to 30" available

38 800.222.5556 | Installation Hotline: 866.ezinpro

A07 Wall/Wall Ceiling/Ceiling (8" (200mm) system shown) W

••Flat seal allows for 25% thermal H1 movement. H1 ••3/8" (10mm) Drywall within S H2 S center pan cover to be painted or wall covered to reduce sightline. A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown) W ••Intended for use on joints with a high degree of thermal movement. H1 H2 S

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 223-A07-150 6" 152 5/8" 16 6" 150 * * 2" 51 2" 51 223-A07-200 8" 200 5/8" 16 6" 150 * * 2" 51 2" 51 223-A07-250 10" 250 5/8" 16 6" 150 * * 2" 51 2" 51 Wall to Wall 223-A07-300 12" 300 5/8" 16 6" 150 * * 2" 51 2" 51 223-A07-350 14" 350 5/8" 16 6" 150 * * 2" 51 2" 51 223-A07-400 16" 400 5/8" 16 6" 150 * * 2" 51 2" 51 223-A07-450 18" 450 5/8" 16 6" 150 * * 2" 51 2" 51 223-A09-150 6" 152 5/8" 16 3" 75 * * 1" 25 1" 25 223-A09-200 8" 200 5/8" 16 3" 75 * * 1" 25 1" 25 223-A09-250 10" 250 5/8" 16 3" 75 * * 1" 25 1" 25 Wall to Corner 223-A09-300 12" 300 5/8" 16 3" 75 * * 1" 25 1" 25 223-A09-350 14" 350 5/8" 16 3" 75 * * 1" 25 1" 25 223-A09-400 16" 400 5/8" 16 3" 75 * * 1" 25 1" 25 223-A09-450 18" 450 5/8" 16 3" 75 * * 1" 25 1" 25 Larger sizes available

233 Series - Drywall

••Flat seal allows for 25% thermal A07 Wall/Wall Ceiling/Ceiling H1H1 (8" (200mm) system shown) 5/8” (16mm) movement prior to engaging WW center bar spring which allows S for the full 50% movement. S Expansion Joint S yst e ms ••3/8" (10mm) Drywall within H2 SS S center pan cover to be painted or wall covered to reduce sightline. A09 Wall/Corner Wall/Ceiling WW H2 (8" (200mm) system shown) ••Intended for use on joints with both thermal and seismic capable needs.

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 233-A07-150 6" 152 5/8" 16 6" 150 * * 3" 76 3" 76 233-A07-200 8" 200 5/8" 16 6" 150 * * 4" 102 4" 102 233-A07-250 10" 250 5/8" 16 6" 150 * * 5" 127 5" 127 Wall to Wall 233-A07-300 12" 300 5/8" 16 6" 150 * * 6" 152 6" 152 233-A07-350 14" 350 5/8" 16 6" 150 * * 7" 178 7" 178 233-A07-400 16" 400 5/8" 16 6" 150 * * 8" 203 8" 203 233-A07-450 18" 450 5/8" 16 6" 150 * * 9" 229 9' 229 233-A09-150 6" 152 5/8" 16 3" 75 * * 1 1/2" 38 1 1/2" 38 233-A09-200 8" 200 5/8" 16 3" 75 * * 2 51 2 51 233-A09-250 10" 250 5/8" 16 3" 75 * * 2 1/2" 64 2 1/2" 64 Wall to Corner 233-A09-300 12" 300 5/8" 16 3" 75 * * 3 76 3 76 233-A09-350 14" 350 5/8" 16 3" 75 * * 3 1/2" 89 3 1/2" 89 233-A09-400 16" 400 5/8" 16 3" 75 * * 4 102 4 102 233-A09-450 18" 450 5/8" 16 3" 75 * * 4 1/2" 114 4 1/2" 114 Larger sizes available. Custom size joints of 30"+ available. inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 39 Wall and Ceiling - Drywall Flush Mount

243 Series - Drywall

••Pleated seal allows for 50% WW movement within system prior to A07 Wall/Wall Ceiling/Ceiling engaging center bar spring. (8" (200mm) system shown) H1 ••Ideal for environments where S H2 S a high degree of both thermal and seismic movement joint W fluctuation is expected. A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown) ••3/8" (10mm) Drywall within center pan cover to be painted or H1 wall covered to reduce sightline. H2 S W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 243-A07-150 6" 152 5/8" 16 6" 150 * * 3” 76 3” 76 243-A07-200 8" 200 5/8" 16 8" 200 * * 4” 102 4” 102 243-A07-250 10" 250 5/8" 16 10" 250 * * 5” 127 5” 127 Wall to Wall 243-A07-300 12" 300 5/8" 16 12" 300 * * 6” 152 6” 152 243-A07-350 14" 350 5/8" 16 12" 300 * * 7” 178 7” 178 243-A07-400 16" 400 5/8" 16 12" 300 * * 8” 203 8” 203 243-A07-450 18" 450 5/8" 16 12" 300 * * 9” 229 9” 229 243-A09-150 6" 152 5/8" 16 3" 75 * * 1 1/2" 38 1 1/2" 38 243-A09-200 8" 200 5/8" 16 4" 100 * * 2 51 2 51 243-A09-250 10" 250 5/8" 16 5" 125 * * 2 1/2" 64 2 1/2" 64 Wall to Corner 243-A09-300 12" 300 5/8" 16 6" 150 * * 3 76 3 76 243-A09-350 14" 350 5/8" 16 6" 150 * * 3 1/2" 89 3 1/2" 89 243-A09-400 16" 400 5/8" 16 6" 150 * * 4 102 4 102 243-A09-450 18" 450 5/8" 16 6" 150 * * 4 1/2" 114 4 1/2" 114 Larger sizes available. Custom size joints of 30" available.

253 Series - Aluminum Plate A07 Wall/Wall Ceiling/Ceiling Ww (8" (200mm) system shown) ••System allows for thermal and seismic movement without H1 the use of the Santoprene seals. Ss ••Metal center pan can be A09 Wall/Corner Wall/Ceiling fabricated to meet any joint width WW (8" (200mm) system shown) requirement. H1H1 5 ••System can be utilized in exterior /8” (16mm) environments as well as interior. ••Clear anodized finish standard. S

W H1 S B Thermal Movement +/- Seismic Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm US mm 253-A07-100 4" 102 5/8" 16 14 3/4" 375 * * 2" 51 2" 51 2" 51 2" 51 253-A07-150 6" 152 5/8" 16 17" 132 * * 2" 51 2" 51 3" 76 3" 76 Wall to Wall 253-A07-200 8" 200 5/8" 16 19" 483 * * 2" 51 2" 51 4" 102 4" 102 253-A07-250 10" 250 5/8" 16 21" 534 * * 2" 51 2" 51 5" 127 5" 127 253-A07-300 12" 300 5/8" 16 23" 585 * * 2" 51 2" 51 6" 152 6" 152 253-A09-100 4" 102 5/8" 16 9 1/4" 235 * * 1" 25 1" 25 1 25 1 25 5 1 1" 1" 1 1/2" Wall to 253-A09-150 6" 152 /8" 16 11 /2" 289 * * 25 23 1 1/2" 38 38 253-A09-200 8" 200 5/8" 16 13 3/8" 340 * * 1" 25 1" 25 2 51 2 51 Corner 253-A09-250 10" 250 5/8" 16 16 1/8" 410 * * 1" 25 1" 25 2 1/2" 64 2 1/2" 64 253-A09-300 12" 300 5/8" 16 18 1/8" 460 * * 1" 25 1" 25 3 76 3 76

40 800.222.5556 | Installation Hotline: 866.ezinpro Project Profile: Owensboro Health Owensboro, Kentucky

The Project Owensboro Medical Health Center, Owensboro Campus – Owensboro, Kentucky

HGA Architects designed the 780,000 square- foot, 9-story tall Medical Center. The 145 acre medical complex boasts a 447 bed inpatient Tower, Diagnostics and Treatment Building, Emergency Department, Women’s Center and Heart Center.

The Challenge Special treatment of the built environment was the driving factor in many design decisions- the goal was to create a warm, healing environment that was welcoming to the diverse patient population.

HGA consulted with a team of JointMaster® engineers to explore expansion joint cover options. The main focus was to reduce joint systems sightlines to a bare minimum so as not to detract from the richly finished aesthetic. This was no small task considering expansion

joint structural gaps started at 4" on the Expansion Joint S yst e ms ground floor and incrementally increased in sizes up to 36" on the floor decks, interior walls, exterior façade and roofs. In addition, there was mounting of drywall, so paint and wallcovering finishes continued a requirement to design a 30" wide joint cover uninterrupted. Our wide, pleated seal products were utilized in the that allowed for the exterior to be skinned in a ceilings as well. continuously glazed curtain wall system as well The exterior system design was a true marvel with the development as a stone veneer. The hurdles included heavy and release of the JointMaster 601 Stealth™ Series exterior system. material weights, matching reveal patterns This allowed the architects to seamlessly incorporate façade and incorporating an insulation system to help materials into the expansion cover. Spandrel glazing was mounted reduce HVAC lifecycle costs. within the covers on the high profile, curvilinear veneer. Behind The Solution the joint centerpan contained an Insulated Vapor Barrier system JointMaster® met the challenge by developing maintaining an R-Value of 15+ while matching the vertical shear seismic-capable joint covers that took on the movement capabilities of the Stealth cover. adjacent finishes to mask their sheer size. JointMaster provided on-site support during construction to assist Interior floor systems incorporated carpeting crews with installation. Systems utilized on this project include our and ceramic tile. The interior walls contained 223 Floor joints, 243 Wall covers, 601 Stealth, 612 and 616 Series recessed cover plates allowing for the Exteriors, as well as Foam Seals and the 975 Fire Barrier systems.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 41 Wall and Ceiling - Glide Plate, Centering Bar

••Durably engineered systems hold up in interior and exterior wall applications. •• Provide crisp lines and shadows for a clean, finished look. Clear anodized finish standard on these systems. Provides a tough, durable finish that % of MOVEMENT VAPOR BARRIER is easy to clean. ±50% optional JOINT WIDTH fire rated 1" (25mm) – 12" (300mm) optional

300 Series - Glide Plate

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) (2" (51mm) system shown) H1 H1

S W S W ••5/8" recessed frame designed for inset into drywall installations (can be surface mounted as well). ••Snap-fit cover designed for easy on-site assembly, no exposed fasteners make system ideal for public/high abuse conditions.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 300-A07-025 1" 25 5/8" 16 * * 5" 127 2" 51 1/2" 13 1/4" 6 5 1 Wall to Wall 300-A07-050 2" 51 /8" 16 * * 6" 152 2" 51 1" 25 /2" 13 300-A07-075 3" 76 5/8" 16 * * 9" 229 3" 76 1 1/2" 38 3/4" 19 Ceiling to Ceiling 300-A07-100 4" 102 5/8" 16 * * 10" 254 3" 76 2" 51 1" 25 300-A07-150 6" 152 5/8" 16 * * 14" 356 4" 102 3" 76 1 1/2" 38 300-A09-025 1" 25 5/8" 16 * * 2 3/8" 60 2" 51 1/4" 6 1/4" 6 5 3 1 1 Wall to Corner 300-A09-050 2" 51 /8" 16 * * 3 /8" 86 2" 51 /2" 13 /2" 13 300-A09-075 3" 76 5/8" 16 * * 5 3/8" 137 3" 76 3/4" 19 3/4" 19 Wall to Ceiling 300-A09-100 4" 102 5/8" 16 * * 6 3/8" 162 4" 102 1" 25 1" 25 300-A09-150 6" 152 5/8" 16 * * 9 3/8" 238 5" 127 1 1/2" 38 1 1/2" 38

42 800.222.5556 | Installation Hotline: 866.ezinpro 318 Series - Glide Plate

A07 Wall/Wall A09 Wall/Corner (2" (51mm) system shown) (2" (51mm) system shown)

••Specifically designed for vinyl wall covering, although can W W be utilized in conjunction with other finishes as well. ••Single narrow sightline preferred by interior designers.

H1 H1

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 318-A07-050 2" 51 5/8" 16 1/8" 3 * * 1" 25 1/2" 13 Wall to Wall 318-A07-075 3" 76 5/8" 16 1/8" 3 * * 1 1/2" 38 3/4" 19 318-A07-100 4" 102 5/8" 16 1/8" 3 * * 2" 51 1" 25 318-A09-050 2" 51 5/8" 16 1/8" 3 * * 1" 13 1/2" 13 Wall to Corner 318-A09-075 3" 76 5/8" 16 1/8" 3 * * 1 1/2" 38 3/4" 19 318-A09-100 4" 102 5/8" 16 1/8" 3 * * 2" 51 1" 25

481 Series - Centering Bar 491 Series - Surface Mount Centering Bar 481 - A07 Wall/Wall Ceiling/Ceiling 491 - A07 Wall/Wall Ceiling/Ceiling 491 - A09 (4" (100mm) system shown) (4" (100mm) system shown) (6" (150mm) system shown) H1 H1

W S W S SS W ••Adaptable to many wall finishes, including W drywall and tile. Expansion Joint S yst e ms ••491 systems designed for renovations and surface mount installations, lowering on-site installation costs. H1

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 481-A07-050 2" 51 1 1/4" 32 * * 5 3/4" 146 * * 9/16" 14 1" 25 481-A07-075 3" 76 1 1/4" 32 * * 6 3/4" 171 * * 1 1/2" 38 1 1/2" 38 481-A07-100 4" 102 1 1/4" 32 * * 7 3/4" 197 * * 2" 51 2" 51 481-A07-150 6" 152 1 1/4" 32 * * 9 3/4" 248 * * 2 1/2" 64 3" 76 481-A07-200 8" 203 1 1/4" 32 * * 13" 330 * * 4" 102 4" 102 Wall to Wall 481-A07-300 12" 305 1 1/4" 32 * * 19" 483 * * 6" 152 6" 152 Ceiling to Ceiling 491-A07-050 2" 51 5/8" 16 * * 5 3/4" 146 * * 9/16" 14 1" 25 491-A07-075 3" 76 5/8" 16 * * 6 3/4" 171 * * 1 1/2" 38 1 1/2" 38 491-A07-100 4" 102 5/8" 16 * * 7 3/4" 197 * * 2" 51 2" 51 491-A07-150 6" 152 5/8" 16 * * 9 3/4" 248 * * 2 1/2" 64 3" 76 491-A07-200 8" 203 5/8" 16 * * 13" 330 * * 4" 102 4" 102 491-A07-300 12" 305 5/8" 16 * * 19" 483 * * 6" 152 6" 152 481-A09-050 2" 51 1 1/4" 32 * * 3 7/8" 98 * * 1/2" 13 1/2" 13 481-A09-075 3" 76 1 1/4" 32 * * 4 7/8" 124 * * 3/4" 19 3/4" 19 481-A09-100 4" 102 1 1/4" 32 * * 5 7/8" 149 * * 1" 25 1" 25 481-A09-150 6" 152 1 1/4" 32 * * 7 7/8" 200 * * 1 1/2" 38 1 1/2" 38 481-A09-200 8" 203 1 1/4" 32 * * 10 1/2" 267 * * 2" 51 2" 51 Wall to Corner 481-A09-300 12" 305 1 1/4" 32 * * 15 1/2" 394 * * 3" 76 3" 76 Wall to Ceiling 491-A09-050 2" 51 5/8" 16 * * 3 7/8" 98 * * 1/2" 13 1/2" 13 491-A09-075 3" 76 5/8" 16 * * 4 7/8" 124 * * 3/4" 19 3/4" 19 491-A09-100 4" 102 5/8" 16 * * 5 7/8" 149 * * 1" 25 1" 25 491-A09-150 6" 152 5/8" 16 * * 7 7/8" 200 * * 1 1/2" 38 1 1/2" 38 491-A09-200 8" 203 5/8" 16 * * 10 1/2" 267 * * 2" 51 2" 51 491-A09-300 12" 305 5/8" 16 * * 15 1/2" 394 * * 3" 76 3" 76 Larger sizes available inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 43 Wall and Ceiling - Surface Mount

% of MOVEMENT VAPOR BARRIER Cost effective solutions for the many conditions ±25% to ±50% optional encountered in interior walls. JOINT WIDTH fire rated 1" (25mm) – 4" (175mm) optional

811 Series - Variable Degree Cover ••Economical solution for retrofit/ surface mount installations. ••Snap-fit design for easy on- site assembly. ••Clear anodized finish standard.

A07 Wall/Wall Ceiling/Ceiling (1" (25mm) system shown) H1

Unique ratcheted design accommodates uneven or S odd angle wall conditions. W

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) H1

S W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout811-A09-050 Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 811-A07-025 1" 25 3/8" 10 * * 3 1/8" 79 * * 1/2" 13 * * Wall to Wall 811-A07-050 2" 51 3/8" 10 * * 4 5/8" 117 * * 1" 25 * * Ceiling to Ceiling 811-A07-075 3" 76 3/8" 10 * * 6 1/8" 156 * * 1 1/2" 38 * * 811-A07-100 4" 102 3/8" 10 * * 7 5/8" 194 * * 2" 51 * * 811-A09-025 1" 25 3/8" 10 * * 1 3/4" 44 * * 1/4" 6 * * Wall to Corner 811-A09-050 2" 51 3/8" 10 * * 3 1/4" 83 * * 1/2" 13 * * Wall to Ceiling 811-A09-075 3" 76 3/8" 10 * * 4 3/4" 121 * * 3/4" 19 * * 811-A09-100 4" 102 3/8" 10 * * 6 1/4" 159 * * 1" 25 * *

44 800.222.5556 | Installation Hotline: 866.ezinpro 104 Series

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) (2" (51mm) system shown)

S S W W

••Dual durometer seal provides secure fit and optimal flexibility. ••Designed for renovation and surface mount installations. ••Clear anodized finish standard. ••Adaptable to any wall finish.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 104-A07-025 1" 25 * * * * 4 3/4" 121 * * 1/4" 6 1/4" 6 Wall to Wall 104-A07-038 1 1/2" 38 * * * * 5 1/8" 130 * * 3/8" 10 3/8" 10 Ceiling to Ceiling 104-A07-050 2" 51 * * * * 5 5/8" 143 * * 1/2" 13 1/2" 13 104-A07-075 3" 76 * * * * 6 5/8" 168 * * 3/4" 19 3/4" 19 104-A09-025 1" 25 * * * * 2 7/8" 73 * * 1/4" 6 1/4" 6 Wall to Corner 104-A09-038 1 1/2" 38 * * * * 3 5/16" 84 * * 3/8" 10 3/8" 10 Wall to Ceiling 104-A09-050 2" 51 * * * * 3 3/4" 95 * * 1/2" 13 1/2" 13 104-A09-075 3" 76 * * * * 4 3/4" 121 * * 3/4" 19 3/4" 19

118 Series

A07 Wall/Wall A09 Wall/Wall (2" (51mm) system shown) (2" (51mm) system shown) Expansion Joint S yst e ms

WW S WW S

••Dual durometer seal provides secure fit and optimal flexibility. ••Flush mount frame reduces sightline. ••Adaptable to any wall finish.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 118-A07-050 2" 50 * * * * 1 7/ " 47 * * 1/ " 13 1/ " 13 Wall to Wall 8 2 2 118-A07-075 3" 75 * * * * 2 7/8" 73 * * 3/4" 19 3/4" 19 118-A09-050 2" 50 * * * * 1 7/ " 47 * * 1/ " 13 1/ " 13 Wall to Corner 8 2 2 118-A09-075 3" 75 * * * * 2 7/8" 73 * * 3/4" 19 3/4" 19 inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 45 Project Profile: Oregon Health & Science University Collaborative Life Sciences Building Portland, Oregon

Architect: SERA Architects, Portland, Oregon

General Contractor: JE Dunn Construction, Portland, Oregon

The Project The $295 million, 500,000 sq. ft. Collaborative Life Sciences Building will place portions of Oregon Health & Science University, Oregon State University and Portland State University under one roof. This project is anticipated to achieve LEED Platinum certification, and will serve more than 1,600 students annually.

JointMaster® products used • 180 LF of floor systems • 600 LF of interior/exterior wall systems • 380 LF of roof systems • R-15 insulated vapor barrier

46 800.222.5556 | Installation Hotline: 866.ezinpro Exterior Joint Systems

Protect appearances by making expansion joints disappear with our exterior joint systems. We've mastered this with our 601 Stealth™ Series. Seamlessly integrating into any façade and eliminating sightline, the 601 Series is ideal for high-end exteriors. Expansion Joint S yst e ms

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 47 Exterior Joint Systems - Seal Systems

615 Series - Flush Mount

615 | 621 VAPOR BARRIER % of MOVEMENT ••Industry unique seal profile holds tight, linear lines. optional EPDM (612) ±50% ••Linear Santoprene® seal design allows for fluid seismic movement Integral Backseal (616/621) during joint expansion and contraction. JOINT WIDTH fire rated ••Field heat-weldable Santoprene seals for weather tight seams and 2" (51mm) – 24" (600mm) optional crisp transitions. ••Seal walls are among the thickest in the industry allowing our product to be used in soffits and corridor ceilings with no sagging.

Insulated Vapor Barrier A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown) Option Available.

Throat mount W S brackets reduce sightline to width of seal only.

Pleated Santoprene® H1 seal design allows for fluid seismic movement.

A09 Wall/Corner Wall/Ceiling (3" (75mm) system shown)

W S

H1

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 615-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25 Wall to Wall 615-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Ceiling to Ceiling 615-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51 615-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76 615-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25 Wall to Corner 615-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38 Wall to Ceiling 615-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51 615-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

48 800.222.5556 | Installation Hotline: 866.ezinpro 616 Series - Flush Mount A07 Wall/Wall, Ceiling/Ceiling­ ­ (12" (300mm)­­ system shown) SS

H1H1

WW

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 616-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102 616-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127 Wall to Wall 616-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152 616-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229 616-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305 616-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102 616-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127 Wall to Corner 616-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152 616-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229 616-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305 Larger sizes available 620 Series - Surface Mount A07 Wall/Wall A09 Wall/Corner (2" (51mm) system shown) (3" (75mm) system shown) H2 •• Surface mount frame design eases installation in narrow joints and wall to W S W corner conditions. S •• Mill finish standard. H1 H1 W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 620-A07-050 2" 51 2 3/8" 60 * * 5 13/16" 148 * * 1" 25 1" 25 Wall to Wall 620-A07-075 3" 76 2 3/8" 60 * * 6 13/16" 173 * * 1 1/2" 38 1 1/2" 38 Ceiling to Ceiling 620-A07-100 4" 102 2 3/8" 60 * * 7 13/16" 198 * * 2" 51 2" 51 620-A07-150 6" 152 2 3/8" 60 * * 9 13/16" 249 * * 3" 76 3" 76 Expansion Joint S yst e ms 620-A09-050 2" 51 2 3/8" 60 4 3/8" 111 3 7/8" 98 * * 1" 25 1" 25 Wall to Corner 620-A09-075 3" 76 2 3/8" 60 4 3/8" 111 4 7/8" 124 * * 1 1/2" 38 1 1/2" 38 Wall to Ceiling 620-A09-100 4" 102 2 3/8" 60 4 3/8" 111 5 7/8" 149 * * 2" 51 2" 51 620-A09-150 6" 152 2 3/8" 60 4 3/8" 111 7 7/8" 200 * * 3" 76 3" 76 621 Series - Surface Mount SS A07 Wall/Wall, Ceiling/Ceiling­ ­ (12" (300mm)­­ system shown) H1H1

W W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 621-A07-200 8" 200 3" 75 * * 12" 300 * * 4" 102 4" 102 621-A07-250 10" 250 3" 75 * * 14" 350 * * 5" 127 5" 127 Wall to Wall 621-A07-300 12" 300 3" 75 * * 16" 400 * * 6" 152 6" 152 621-A07-450 18" 450 3" 75 * * 22" 550 * * 9" 229 9" 229 621-A07-600 24" 600 3" 75 * * 28" 700 * * 12" 305 12" 305 621-A09-200 8" 200 3" 75 * * 10" 250 * * 4" 102 4" 102 621-A09-250 10" 250 3" 75 * * 12" 300 * * 5" 127 5" 127 Wall to Corner 621-A09-300 12" 300 3" 75 * * 14" 350 * * 6" 152 6" 152 621-A09-450 18" 450 3" 75 * * 20" 500 * * 9" 229 9" 229 621-A09-600 24" 600 3" 75 * * 26" 650 * * 12" 305 12" 305 Larger sizes available inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 49 Exterior Joint Systems - Flush Mount

% of MOVEMENT VAPOR BARRIER ••Ideal system for high-end exterior systems or conditions where ±50% optional the structural joint is located in a high profile position on the building veneer. JOINT WIDTH fire rated ••Flush mounted exterior system reduces sightline to two reveals of 12" (305mm) – 36"(914mm) optional approximately 1" (25mm) and 3" (76mm) dimensions. ••System is seismic-capable while allowing for daily thermal 601 Stealth™ Series movement and wind sway considerations. ••The Hinged Cover plate or ”pan” can be infilled with ••Compression spring shock absorption assembly correctly repositions adjacent Architectural Systems to disguise the expansion the pan to the normal position after a system movement. joint (Glazing, Metal panels and the Masonry units such as Stone and Brick).

601 Stealth™ Series - Flush Mount

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

W2 "A" H1 Closed/Nominal Position

"A"

W1 Operational Position

Seismic Movement W1 W2 H1 S1 S2 Thermal Movement +/- +/- Application System Joint Width Frame Height 1 Height 2 Sightline Sightline Horiz. Vert. Horiz. Vert. US mm US mm US mm US mm US mm US mm US mm US mm 601-A07/A09-300 12" 305 17 1/2" 445 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 6" 152 Wall to Wall 601-A07/A09-450 18" 457 23 1/2" 597 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 9" 229 Ceiling to Ceiling 601-A07/A09-600 24" 610 29 1/2" 749 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 12" 305 System available in any variation of size for 10" (250mm) -30" (750mm) expansion gaps

50 800.222.5556 | Installation Hotline: 866.ezinpro Exterior Joint Systems - Surface Mount

651 Series - Surface Mount

A07 Wall/Wall A09 Wall/Corner (2" (51mm) system shown) (2" (51mm) system shown) H1 H1

••Surface mount frame accommodates uneven W S joint widths. S W ••Rubberized washers prevent the elements from penetrating the cover plate at anchor points. ••Factory formed transitions available. * Available with center bar (652) ••Mill finish standard – custom finishes available on pages 66-67.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical 651-A07-050 651-A09-050 US mm US mm US mm US mm US mm US mm US mm 651-A07-025 1" 25 1 1/4" 32 * * 4 1/4" 108 * * 1/2" 13 1/2" 13 651-A07-050 2" 51 1 1/4" 32 * * 5 1/4" 133 * * 1" 25 1" 25 1 1 1 1 Wall to Wall 651-A07-075 3" 76 1 /4" 32 * * 6 /4" 159 * * 1 /2" 38 1 /2" 38 651-A07-100 4" 102 1 1/4" 32 * * 7 1/4" 184 * * 2" 51 2" 51 Ceiling to Ceiling 651-A07-150 6" 152 1 1/4" 32 * * 10 1/2" 267 * * 3" 76 3" 76 651-A07-200 8" 203 1 1/4" 32 * * 13 1/2" 343 * * 4" 102 4" 102 651-A07-300 12" 305 1 5/16" 33 * * 19 1/2" 495 * * 6" 152 6" 152 651-A09-025 1" 25 1 1/4" 32 * * 2 5/8" 67 * * 1/2" 13 1/2" 13 651-A09-050 2" 51 1 1/4" 32 * * 3 5/8" 92 * * 1" 25 1" 25 Wall to Corner 651-A09-075 3" 76 1 1/4" 32 * * 5" 127 * * 1 1/2" 38 1 1/2" 38 Wall to Ceiling 651-A09-100 4" 102 1 1/4" 32 * * 6 1/2" 165 * * 2" 51 2" 51 651-A09-150 6" 152 1 1/4" 32 * * 9 1/2" 241 * * 3" 76 3" 76 651-A09-200 8" 203 1 1/4" 32 * * 12 1/2" 318 * * 4" 102 4" 102

Larger sizes available Expansion Joint S yst e ms

University of Utah L.S. Skaggs, Salt Lake City, UT 601 Stealth™ Series

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 51 Exterior Joint Systems - Aluminum Roof Covers

% of MOVEMENT VAPOR BARRIER Exterior roof systems available in standard hard- ±50% Included (661), Optional (672) lid aluminum covers as well as flexible, closed cell EPDM bellows configurations. JOINT WIDTH fire rated 1" (25mm) – 12"(300mm) optional

661 Series - Curb Mounted Centering Bar

A01 Roof/Wall A02 Roof/Wall (2" (51mm) system shown) S (8" (203mm) system shown) H1 S

W 661 – 45° Curb Mounted ••Frame angled to assist in securing roofing A02 Roof/Wall H1 membrane down on 45° curb. (2" (51mm) system shown) S ••Moisture barrier included. ••Weather washers prevent leaking where H1 fasteners penetrate frames/covers. ••Factory preformed transitions available. W ••Mill finish standard. W ••Custom options on pages 66-67.

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 661-A01-025 1" 25 1 1/4" 32 * * 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13 661-A01-050 2" 51 1 1/4" 32 * * 5 1/4" 133 8 7/8" 225 1" 25 1" 25 661-A01-075 3" 76 1 1/4" 32 * * 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38 Roof to Roof 661-A01-100 4" 102 1 1/4" 32 * * 7 1/4" 184 10 5/8" 270 2" 51 2" 51 661-A01-150 6" 152 1 1/4" 32 * * 10 1/2" 267 12 1/8" 308 3" 76 3" 76 661-A01-200 8" 203 1 1/4" 32 * * 13 1/2" 343 14 1/8" 359 4" 102 4" 102 661-A01-300 12" 305 1 3/8" 35 * * 19 1/2" 495 18 1/8" 460 6" 152 6" 152 661-A02-025 1" 25 1 1/4" 32 * * 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13 661-A02-050 2" 51 1 1/4" 32 * * 3 5/8" 92 5 3/8" 137 1" 25 1" 25 661-A02-075 3" 76 1 1/ " 32 * * 5" 127 6 3/ " 162 1 1/ " 38 1 1/ " 38 Roof to Wall 4 8 2 2 661-A02-100 4" 102 1 1/4" 32 * * 6 1/2" 165 7 3/8" 187 2" 51 2" 51 661-A02-150 6" 152 1 1/4" 32 * * 9 1/2" 241 9 3/8" 238 3" 76 3" 76 661-A02-200 8" 203 1 1/4" 35 * * 12 1/2" 318 11 3/8" 289 4" 102 4" 102 Larger sizes available

52 800.222.5556 | Installation Hotline: 866.ezinpro 691 Series - Vertical Curb Mount

••Easy on-site assembly A01 Roof/Roof and installation. (2" (51mm) system shown) A02 Roof/Wall (2" (51mm) system shown) ••Multi-directional seismic movement. S S ••Moisture barrier included. ••Neoprene weather washers prevent H1 leaking where fasteners penetrate H1 frames/covers. ••2x wood blocking mount. ••Factory formed transitions available. ••Cover plate available in stainless steel or alternate secondary finishes. W W

W H1 S B Movement +/- Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm 691-A01-025 1" 25 1 1/4" 32 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13 691-A01-050 2" 51 1 1/4" 32 5 1/4" 133 8 7/8" 225 1" 25 1" 25 691-A01-075 3" 76 1 1/4" 32 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38 Roof to Roof 691-A01-100 4" 102 1 1/4" 32 7 1/4" 184 10 5/8" 270 2" 51 2" 51 691-A01-150 6" 152 1 1/4" 32 10 1/2" 267 12 1/8" 308 3" 76 3" 76 691-A01-200 8" 203 1 1/4" 32 13 1/2" 343 14 1/8" 359 4" 102 4" 102 691-A01-300 12" 305 1 3/8" 35 19 1/2" 495 18 1/8" 460 6" 152 6" 152 691-A02-025 1" 25 1 1/4" 32 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13 691-A02-050 2" 51 1 1/4" 32 3 5/8" 92 5 3/8" 137 1" 25 1" 25 691-A02-075 3" 76 1 1/ " 32 5" 127 6 3/ " 162 1 1/ " 38 1 1/ " 38 Roof to Wall 4 8 2 2 691-A02-100 4" 102 1 1/4" 32 6 1/2" 165 7 3/8" 187 2" 51 2" 51 691-A02-150 6" 152 1 1/4" 32 9 1/2" 241 9 3/8" 238 3" 76 3" 76 691-A02-200 8" 203 1 1/4" 35 12 1/2" 318 11 3/8" 289 4" 102 4" 102 Larger sizes available

Available Transitions ••Metal and EPDM-Bellow Joint transitions available – Consult with your Sales Representative to determine which of our many configurations apply to your unique building conditions. Expansion Joint S yst e ms

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 53 Exterior Joint Systems - Bellows Systems

672 | 674 Bellows

••Remains watertight during severe seismic movement. ••Splicing kits available for simple installation. ••Flanges available standard as galvanized optional stainless steel, copper, aluminum and EPDM as well. ••Expansion joints intersect and change directions. Ensure maximum flexibility, clean lines and waterproofing in these critical areas with the application of factory-formed intersections and transitions.

672 Series - Bellows/Canted Roof

G01 Canted Roof/Roof G02 Canted Roof/Wall (2" (51mm) system shown) (2" (51mm) system shown)

4” [102mm]

WW W

W H1 H2 S B Movement +/- 672-A02-050

Application System 672-A01-050Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 672-G01-050 2" 51 * * * * * * * * 1" 25 1" 25 672-G01-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38 Roof to Roof 672-G01-100 4" 102 * * * * * * * * 2" 51 2" 51 672-G01-150 6" 152 * * * * * * * * 3" 76 3" 76 672-G01-200 8" 203 * * * * * * * * 4" 102 4" 102 672-G02-050 2" 51 * * * * * * * * 1" 25 1" 25 672-G02-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38 Roof to Wall 672-G02-100 4" 102 * * * * * * * * 2" 51 2" 51 672-G02-150 6" 152 * * * * * * * * 3" 76 3" 76 672-G02-200 8" 203 * * * * * * * * 4" 102 4" 102

674 Series - Bellows/Curb Flange

G01 Curb Flange Roof/Roof G02 Curb Flange Roof/Wall (2" (51mm) system shown) (2" (51mm) system shown)

2" 2" 2" 2" W W

W H1 H2 S B Movement +/- Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical US mm US mm US mm US mm US mm US mm US mm 674-G01-050 2" 51 * * * * * * * * 1" 25 1" 25 674-G01-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38 Roof to Roof 674-G01-100 4" 102 * * * * * * * * 2" 51 2" 51 674-G01-150 6" 152 * * * * * * * * 3" 76 3" 76 674-G01-200 8" 203 * * * * * * * * 4" 102 4" 102 674-G02-050 2" 51 * * * * * * * * 1" 25 1" 25 674-G02-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38 Roof to Wall 674-G02-100 4" 102 * * * * * * * * 2" 51 2" 51 674-G02-150 6" 152 * * * * * * * * 3" 76 3" 76 674-G02-200 8" 203 * * * * * * * * 4" 102 4" 102

54 800.222.5556 | Installation Hotline: 866.ezinpro Seals

Our Compression Seals create crisp, linear sightlines with a patented design to eliminate waviness. They’re also engineered to make installation easier and heat weldable. Both Compression Seal and Foam Seal products are 100% weather tight, UV resistant and built to last through extreme temperatures and chemicals. Expansion Joint S yst e ms

College of San Mateo 616 Joint System inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 55 1200 Series 1200 Series (2" (50mm) system shown) (2" (50mm) double-sided system shown)

W

1200 W SERIES

Foam Seals 2 3/16" (60mm)

1250 Series 1250 Series (2" (50mm) system shown) (2" (50mm) double-sided system shown)

W

W 1250 SERIES

2 3/16" 1200 Series 1200 Series (60mm) 1250 Series 1200 Series(2" (50mm) – system Seal shown) (2" (50mm) double-sided system shown) (2" (50mm) Custom triple-sided system shown)

W WW W W 1200 W SERIES

(2" (50mm) double-sided (2" (50mm) custom H1

3 system shown) triple-sided system shown) 2 /16" (2" (50mm) system shown) (60mm)

1250 Series 1250 Series • Foam seals create(2" (50mm) asystem watertight, shown) insulated(2" (50mm) double-sided seal. system shown) • 1200 foam seal comes pre-compressed and includes peel and W • Capable of handling vertical and horizontal joint movement. stick adhesive sides, making installation easy. • Available in 26 standard colors (custom colors available • Available in single, double or triple faced versions. W 1250 upon request). See pagesSERIES 66-67 for color options. • Excellent sound attenuation qualities reaching an STC rating of 52.

W H1 Movement +/- Application System Joint Width Seal Depth Horizontal Vertical 2 3/16" (60mm) 1250 Series (2" (50mm) Custom triple-sided systemUS shown) mm US mm US mm US mm 1200-050 1/2" 13 1 1/2" 38 1/4" 6 1/4" 6 1200-100 1" 25 1 1/2" 38 1/2" 13 1/2" 13 W Floor to Floor 1200-150 1 1/2" 38 2" 51 3/4" 20 3/4" 20 1200-200 2" 51 2" 51 1" 25 1" 25 Floor to Wall 1200-250 2 1/2" 64 2" 51 1 1/4" 32 1 1/4" 32 Wall to Wall 1200-300 3" 76 3" 76 1 1/2" 38 1 1/2" 38 1200-350 3 1/2" 89 3" 76 1 3/4" 44 1 3/4" 44 Wall to Corner 1200-400 4" 102 4" 102 2" 51 2" 51 1200-500 5" 127 4" 102 2 1/2" 64 2 1/2" 64 1200-600 6" 152 4" 102 3" 76 3" 76 Other sizes available

1250 Series 1250 Series – Seal (2" (50mm) system shown)

• Foam seals create a watertight, insulated seal. • Capable of handling vertical and horizontal joint movement. • Available in 26 standard colors (custom colors available upon request). W See pages 66-67 for color options. • 1250 system is compressed in field and installed utilizing silicone or epoxy adhesive (supplied by others). • Good sound attenuation qualities. H1 (2" (51mm) system shown)

W H1 Movement +/- Application System Joint Width Seal Depth Horizontal Vertical US mm US mm US mm US mm 1250-050 1/2" 13 1 1/2" 38 1/8" 3 1/8" 3 1250-100 1" 25 1 1/2" 38 1/4" 6 1/4" 6 Floor to Floor 1250-150 1 1/2" 38 2" 51 3/8" 9 3/8" 9 1250-200 2" 51 2" 51 1/2" 13 1/2" 13 Floor to Wall 1250-250 2 1/2" 64 2" 51 5/8" 16 5/8" 16 Wall to Wall 1250-300 3" 76 3" 76 3/4" 20 3/4" 20 1250-350 3 1/2" 89 3" 76 7/8" 22 7/8" 22 Wall to Corner 1250-400 4" 102 4" 102 1" 25 1" 25 1250-500 5" 127 4" 102 1 1/4" 32 1 1/4" 32 1250-600 6" 152 4" 102 1 1/2" 38 1 1/2" 38 Other sizes available

56 800.222.5556 | Installation Hotline: 866.ezinpro 1100 Series – Seal

• High heat, weather and UV resistant. • 100% watertight foam seal. H1 • Excellent for roof applications and under metal cover plate systems. • Allows for 50% Tension | 60% Compression | W 100% Shear movement. • Available in Gray only. (2" (51mm) system shown) • Field applied paint coating available (JPR007).

Movement + / - Nominal Joint Width (W) Seal Depth (H) Application System Compression Expansion US mm US mm US mm US mm 1100-100 1" 25 2" 51 .4" 10 1.8" 46 1100-150 1 1/2" 38 2" 51 .8" 20 2.6" 66 1100-200 2" 51 2" 51 1.1" 27 3.6" 91 1100-250 2 1/2" 64 2" 51 1.3" 33 4.2" 107 Floor to Floor 1100-300 3" 76 3" 76 1.6" 40 5.2" 132 1100-350 3 1/2" 89 3" 76 1.8" 46 5.8" 147 1100-400 4" 102 4" 101 2" 51 6.5" 165 1100-450 4 1/2" 114 4" 101 2.2" 56 7.3" 185 1100-500 5" 127 4" 101 2.5" 64 8.1" 206 Other sizes available 1150 Series – Seal • Chemical, weather and UV resistant. • 100% watertight foam seal. H1 • Excellent when in contact with grade or oils. • Allows for 25% Tension | 50% Compression | 100% Shear movement. W • Ridged sides trap and pool epoxy (JPR003) providing superior adhesion to the joint surface to resist imposed loads. (2" (51mm) system shown) • Available in Gray only. • Field applied paint coating available (JPR007).

Movement + / - Nominal Joint Width (W) Seal Depth (H) Application System Compression Expansion US mm US mm US mm US mm 1150-100 1" 25 2" 51 .5" 13 1.25" 32 1150-200 2" 51 2" 51 1" 25 2.5" 64 Expansion Joint S yst e ms 1150-300 3" 76 3" 76 1.5" 38 3.75" 95 1150-400 4" 102 4" 101 2" 51 5" 127 Floor to Floor 1150-500 5" 127 4" 101 2.5" 64 6.25" 159 1150-600 6" 152 5" 127 3" 76 7.5" 191 1150-700 7" 178 5" 127 3.5" 83 8.75" 222 1150-800 8" 203 5" 127 4" 89 10" 254

1175 Series – Seal

• Developed to meet DOT performance requirements. H1 • Allows for 100% shear movement. • Seal is UV stable and resistant to solvents and fuels. • Arrives to site pre-compressed and is installed with epoxy. W • Available in Gray only. (2" (51mm) system shown)

Movement ± Joint Width (W) Seal Depth (H) Application System Compression/Expansion US mm US mm US mm 1175-100 1" 25 1 1/2" 38 1/2" 13 1175-200 2" 51 2" 51 1175 1" 25 Floor to Floor SERIES 1175-300 3" 76 3" 76 1 1/2" 38 1175-400 4" 102 4" 102 2" 51 Larger sizes available

(OPTIONAL)FIRE BARRIER: SELF-LEVELING SEALANT AND inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions MINERAL WOOL57 SHOWN Compression Seals - Parking and Open Structure

AR Series – Seal

• Heavy pedestrian/Moderate vehicle loading capabilities. W • Incorporation of ribs on side faces to aid in pooling epoxy 1/8" and adding surface area for increased adhesion to deck. • Installed with 2-part epoxy. H1H1 • Field heat-welded seams provide 100% watertight conditions. • Patent Pending (2" (51mm) system shown)

H1 Seismic Seismic Nominal Joint Width Minimum Joint Width Maximum Joint Width Application System Seal Depth US mm US mm US mm US mm AR-100S 1” 25 3/4” 21 1-1/2” 39 2” 52 Architectural AR-200S 2" 50 1" 25 3" 75 2 3/16" 56 Compression AR-300S 3" 75 1 1/2" 38 4 1/2" 114 3 5/16" 84 Seals AR-400S 4" 100 2" 51 6" 152 3 5/16" 84 *Industry best practices dictate seals should always be kept in compression.

CR Series – Seal

• Heavy Duty and high rate vehicular applications. W 1/8" • Installed with a primer and Elastomeric concrete header at the nosings for secure placement and impact resistance. H1 • Field heat welded seams provide 100% watertight conditions.

• Patent Pending (2" (51mm) system shown)

B H1 Nominal Joint Width Minimum Joint Width Maximum Joint Width Application System Blockout Seal Depth US mm US mm US mm US mm Architectural CR-200S 2" 50 1 1/2" 38 2 1/2" 57 3" 75 2 3/16" 56 Compression CR-300S 3" 75 2 1/4" 57 3 1/2" 89 3" 75 3 5/16" 84

Seals CR-400S 4" 100 3" 76 5" 127 3" 75 3 5/16" 84

DR Series – Seal W • Heavy Duty pedestrian/vehicular loading capabilities. 1/8" • Appropriate for horizontal applications. • Provides for fast installation utilizing a no-mix “Lubricant H1 Adhesive” (JPR009). • Installation conditions are not weather sensitive. .75" (19mm} system shown

H1 Nominal Joint Width Minimum Joint Width Maximum Joint Width Application System Seal Depth US mm US mm US mm US mm DR-075 3/16" 19 7/16" 11 1 1/16" 27 1 1/16" 27 Architectural DR-100 1" 25 5/8" 16 1 3/8" 35 1 1/8" 29 Compression DR-125 1 1/4" 32 3/4" 19 1 3/4" 45 1 1/2" 38 Seals DR-150 1 1/2" 38 7/8" 22 2 1/8 54 2 1/2" 64 DR-175 1 3/4" 45 1 3/16" 30 2 9/16 65 2 1/2" 64

58 800.222.5556 | Installation Hotline: 866.ezinpro Accessories

We cover all your building needs in one place with accessories to protect your structures from damage. Whether it's Fire Barriers, Vapor Barriers or Parking Protection products, you finally have a one-stop shop that can outfit you with a comprehensive line of industry- leading solutions. Expansion Joint S yst e ms

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 59 Fire Barriers - 900 Series

We have Fire Barrier configurations available to meet any project’s needs. Building expansion joint and slab openings inherently create a pathway for fire and smoke to travel and spread throughout the structure. JointMaster’s broad array of Fire Barrier products provide protection for 2, 3 and 4-hour rated conditions to keep the threat contained.

Fire Blankets

975 - Fire Blanket ••1, 2, 3 and 4 hour rated systems available. •• Mounting configurations available for both wall and floor ••Tested in accordance with: UL 2079/ ULC S-115 “FTH” (FTH: Rating conditions: -Top (flush) Mount -Low Profile (recessed) Mount Fire, Temperature and Hose) -ASTM-E119/E1399/E1966. -Bottom Mount ••±50% movement. •• Factory fabricated horizontal and vertical transitions ensure the fire rating requirements of UL 2079 are not compromised - ••Accommodates joint widths from 2” (51mm) to 27” (686mm) wide. Details & directions for field fabricated transitions also available. ••No fire caulk required at splices. •• Water Guard systems are available to protect the blanket ••Single sided installation. system and fire rating during and after construction of open ••Pre-attached flanges drastically reduce labor cost. structures such as parking facilities and stadiums. (Optional drain tubes available.) ••Product comes with factory made male to female splices, eliminating the need for complex field manipulation at seams.

4" (102mm) 757-A014"(102mm) Floor 757-A01 System floor system Shown shown (2" (51mm) floor system shown) (Available only for 975) (Applied to 301-A01 system) GALVANIZED STEEL RETAINING FLANGE

HEX HEAD CONCRETE SCREW

GALVANIZED STEEL FLANGE

HEAT SHIELD 20 GA. GALVANIZED RETAINER MAIN BARRIER Bottom Mount Surface Mount 950 - Fire Blanket

• Our most cost-effective large gap barrier. 4" (102mm) 221-A01 floor system shown • 2 hour rated meeting UL2079, ASTM E-1399, ASTM 4"(102mm) 221-A01 floor system shown E-1966. • Meets “Hose Stream Test” for vertical wall applications. • ±50% seismic movement. • Installs with retaining flanges. GALVANIZED STEEL • Accommodates joint widths from 2" (50mm) to 24" FLANGE (600mm). Low Profile • Chase wall covers available.

60 800.222.5556 | Installation Hotline: 866.ezinpro Fire Barriers

921 | 925 Mineral Wool and Sealant

(1" (25mm) floor system shown) ••Cost effective system for joint widths up (Applied to 106-A01 system) to 3" (127mm). ••Mineral wool supplied in 4' (1.2m) 921 SILICONE lengths and compressed into gap for SEALANT easy installation. ••Up to 3 hour rated meeting UL2079. 925 MINERAL WOOL ••System accommodates horizontal movement to 25%. ••Meets “Hose Stream Test" for masonry walls. REACTOFIRE MINERAL WOOL AND SILICONE SEALANT FIRE BARRIER SYSTEM (OPTIONAL)

935 – Firestop System | 925 | 935 Mineral Wool and Sealant

(1" (25mm) floor system shown) (Applied to 106-A01 system)

ULTRA BLOCK SEALANT INSULATED WOOL 1/2” 13MM DEEP

• Cost effective system for joint widths up to 3" (127mm). • System accommodates horizontal movement to 20%. • Mineral wool supplied in 4’ (1.2m) lengths and • Meets “Hose Stream Test” for masonry walls. compressed into gap for easy installation. • Concrete installations only.

• Up to 3 hour rated meeting UL2079. Expansion Joint S yst e ms

Fire Rated Foam

990/995 – Fire Rated Foam

••Provides a 2 or 3 hour fire rating in accordance with UL-2079 with either 25% or 50% movement capabilities. ••990 system does not rely on the silicone face for its rating. The foam is impregnated with fire retardant material, meaning the rating is not compromised due to vandalism or damage to the silicone face. ••Fire foam seals are watertight and also have sound attenuation qualities. ••Seal material is UV stable and resistant to solvents. ••Capable of handling vertical and horizontal joint movement. ••990 foam seal comes pre-compressed for installation ease. ••System is available in 26 standard colors (custom colors available). See pages 66-67 for color options.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 61 Vapor Barriers - Moisture Deterrent Membranes

Vapor Barriers are designed to resist the penetration of moisture through wall, ceiling and floor assemblies of a structure. JointMaster’s systems are designed to meet the challenges of keeping the elements where they belong- outside. Our membranes deter air currents, wind-driven rain and ensure for the weep of condensation to the exterior.

Standard Vapor Barrier ••High performance, fiber-reinforced EPDM membrane. ••Provided in conjunction with any exterior joints, also available as an additional feature to our complete line of products. ••Allows for joint movement matching the requirements of the Architectural Joint cover. ••Durable .045" (45mil) thick sheet good resists tearing, puncture and wear-through.

Insulated Vapor Barrier With EJ cover frames

••Exterior grade system capable of matching 50% joint movement. H ••Consists of fiber-reinforced EPDM membranes, sandwiching Appox. 1 1/2" [38mm] W Under Frame commercial grade insulation, W With termination bar adhered and pinned together to Termination Bar 1" [25mm] Wide form a seismic-capable assembly. w/ 3/16" [4.8mm] Holes ••Maintains a minimum R-Value of 15. Fastener @12" [305mm] O.C. (By Others) ••Seams and directional transitions designed to ensure a watertight seal H and positive condensation drainage.

W

W H Movement ± Joint Width Insulated Vapor Barrier Depth Application System Compression/Expansion US mm US mm US mm JL006-IVB 6" 152 5" 127 3" 76 Wall to Wall JL008-IVB 8" 203 6" 152 4" 102 Wall to Corner JL010-IVB 10" 254 7" 178 5" 127 JL012-IVB 12" 305 8" 203 6" 152 Roof to Roof JL018-IVB 18" 457 10" 457 9" 229 Roof to Wall JL024-IVB 24" 610 12" 305 12" 305 JL028-IVB 28" 711 14" 356 14" 356

62 800.222.5556 | Installation Hotline: 866.ezinpro Facility Protection

JOS-SPD 1200/1800 – Speed Guard

• Reduces vehicle speeds to 2-5mph (3km/h-8km/h). • Made of environmentally responsible shredded tires, diverting 3.2 (SPD 1200) to 5.1 (SPD 1800) tires from the landfill with every piece ordered. • Reflective in-molded pavement marking strip alerts driver of the tire stops presence in low light situations. • Luminous “Cat Eye” reflectors light up as vehicles approach. • Ideal for areas with heavy pedestrian flow such as End Cap entrances or crosswalks. (Optional) • Greatly reduces risks of pedestrian-car collisions.

• Highly resilient material resists U.V., moisture, Expansion Joint S yst e ms oil and extreme temperatures and will never chip, 2.25 crack or fade. Plus it's capable of conforming to [57mm] 12.00 9.00 72.00 / 48.00 uneven surfaces. [304mm] [228mm] [1.8m] [1.2m]

JOS-TRSTP 500/1800 – Tire Stop

• Tire stop is available in two (2) different lengths – T1800: 6' (1.8M) and T500: 22" (.5m). • Prevents drivers from over parking and encroaching into walkways or other parking spots. • Highly resilient material resists U.V., moisture, oil, extreme temperatures and will never chip, crack, or fade; plus its capable of conforming to uneven surfaces. • Made of environmentally responsible shredded tires, diverting 1 (TRSTP 500) to 3.4 (TRSTP 1800) tires from the landfill with every piece ordered. • Reflective in-molded pavement marking strip alerts Lag Bolt Mounting Hole driver of the tire stops presence in low light situations.

• Available in three (3) colors to designate space type or 4” for facility branding: Black, Blue and Terracotta. [100mm] In-Molded Re ective Strip 6” • Optional in-molded pavement strip colors: [154mm] White or Yellow. 6’ [1.8m] inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 63 JPark-C-075 System Shown

.50 [13mm] CONCRETE SCREW ANCHOR 3 PER WING

EPDM HIGH IMPACT 3.00 CORNER GUARD [78mm]

JOS-CRNR 075 – Standard Corner Guards JPark-C-075S System Shown JPark-C-075 System Shown (Optional High-Vis Strip Shown)

.50 [13mm] CONCRETE SCREW ANCHOR 3 PER WING

HIGH VISIBILTY EPDM STRIP OPTIONAL HIGH IMPACT 3.00 CORNER GUARD 1.00 [78mm] [25mm]

(JOS-CRNR 075 system shown) (JOS-CRNR 075 system shown) JPark-C-075S System Shown (optional High-Visibility strip shown) (Optional High-Vis Strip Shown) • Corner guard height: 39.3" (1m). • Capable of withstanding moderate impact from vehicles. • Economic solution to protect column and wall corners • Optional: high visibility strip helps corner guard standout in from impact. low light areas. • Aids in preventing damage to customers' vehicles.

HIGH VISIBILTY STRIP OPTIONAL

1.00 JOS-CRNR 090 – High Impact Corner Guards [25mm]

.709" [18mm]

3.54" [90mm]

GALVANIZED STEEL RETAINER HIGH IMPACT EPDM CORNER GUARD

• Corner guard height: 39.3" (1m). • Heavy Duty EPDM corner guard snaps onto aluminum • The gold standard for corner protection. retainer clips. • Easy to install and easy to replace if damaged. • Galvanized steel retainer clip protects the corner’s structural integrity. • Large collision chambers cushion door impacts better than any other corner guard. Also, it is more forgiving on side panels and plastic bumpers.

64 800.222.5556 | Installation Hotline: 866.ezinpro JOS-WALL 200 – Wall Guard

1.25 1.25 [32mm] [32mm]

8.00 8.00 [203mm] [203mm]

• Wall guard length: 120" (3m). CONCRETE CONCRETE SCREW ANCHOR SCREW ANCHOR • The gold standard for heavy impact facility wall protection. AS NEEDED AS NEEDED HIGH VISIBILITY HIGH VISIBILITY

• Capable of conforming to straight and curved wall conditions. STRIP OPTIONAL STRIP OPTIONAL Expansion Joint S yst e ms • Can wrap circular columns the diameter of 18" (450mm) and greater.

• Optional: High visibility strip helps wall guard stand out in (JOS-WALL 200 system shown) (JOS-WALL 200 system shown) low light areas. (optional High-Visibility strip shown)

JOS-DOCK 075 – Dock Bumper

3.01 [76mm]

2.80 [71mm]

CONCRETE SCREW ANCHOR

• Standard length of 24" (610mm). • Dock Bumper is made of thick 3/4" (19mm) EPDM capable of withstanding the repeated forces encountered within loading docks. • Mounted using Heavy Duty fasteners. Anchorage locations field drilled to meet project specific requirements. inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 65 Available Finishes

Stocked Finishes

Clear Mill Anodized

Custom Kynar® Color Coatings

Bone Light Ivory Sandstone Burnt Sun Sierra Tan Beige White Seawolf Beige

Charcoal Patine Hartford Dove Gray Slate Gray Dark Ivy Interstate Blue Gray Green Green

Military Colonial Sage Boysenberry Quaker Bronze Black Blue Red Brown

Custom Color Anodized Finishes

Medium Extra-Dark Champagne Light Bronze Dark Bronze Black Bronze Bronze

Due to the printing process, colors may vary. For more accurate color selection, please request samples.

66 800.222.5556 | Installation Hotline: 866.ezinpro Seal Colors

Standard Santoprene® Seals

Bright White Off-White Beige Gray Black

Primary Silicone Seal Colors - Dow Corning® 790

Bright White Precast White Limestone Natural Stone Sandstone Adobe Tan Dusty Rose Expansion Joint S yst e ms

Rustic Brick Blue Spruce Bronze Charcoal Black Grey

Secondary Silicone Seal Colors - Pecora® 890 NST

Anodized Aluminum Tru White Precast Beige Limestone Natural Stone Aluminum Stone

Classic Hartford Sandstone Charcoal Gray Black Red Rock Bronze Green

"Primary" indicates standard cost and leadtime. "Secondary" indicates standard cost and extended leadtime. Due to the printing process, colors may vary. For more accurate color selection, please request samples. inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 67 inprocorp.com • 800.222.5556 • 262.679.9010 • World Headquarters S80 W18766 Apollo Drive, Muskego, WI 53150 USA

ISO 14001:2013 ISO 9001:2014 Printed with soy ink on recycled fiber including 10% post-consumer fiber. CERTIFIED CERTIFIED ©2015 Inpro Corporation / XX00