SIP Roofing Panel Connection Diagrams
Total Page:16
File Type:pdf, Size:1020Kb
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. FOAM AS RECOMMENDED CORE BY MANUFACTURER DRYWALL CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED 8d COMMON NAILS BY MANUFACTURER @ 6" O.C. EACH SIDE WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION Fig. 2 DRYWALL SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT SIP WALL DRAINED AND VENTILATED CLADDING FLOOR JOIST FIELD INSTALLED PANEL BOTTOM PLATE 16d NAILS INTO SILL PLATE @ 16" O.C. 8d COMMON NAILS @ 6" O.C. BOTH SIDES TREATED SILL PLATE BE SURE OUTSIDE SILL SEALER SKIN IS SUPPORTED BY SILL PLATE TERMITE SHIELD CONCRETE CONTINUOUS SEALANT EACH SIDE OF OR MASONRY FRAMING TYP. AS RECOMMENDED BY FOUNDATION MANUFACTURER WALL MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS @ 6 FEET O.C. MAXIMUM FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL A Fig. 3 SIP WALL DRAINED AND VENTILATED CLADDING DRYWALL CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER FIELD INSTALLED 8d COMMON NAILS @ 6" TREATED BOTTOM O.C. EACH SIDE PLATE CAPILLARY BREAK, MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS MIN. 6 MIL POLY OR @ 6 FEET O.C. MAXIMUM MIN. 3/4" PRESSURE- TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES TERMITE SHIELD CONCRETE OR MASONRY FOUNDATION WALL FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL B Fig. 4 SIP WALL DRAINED AND VENTILATED CLADDING DRYWALL FIELD INSTALLED TREATED BOTTOM PLATE 8d COMMON SUBFLOOR OR COMBINED SUBFLOOR NAILS @ 6" AND UNDERLAYMENT, TYP. O.C. EACH SIDE FLOOR JOIST 16d NAILS INTO FLOOR JOIST PLATE @ 16" O.C. WHEN USED AS BRACING (3) 16d @ 16” O.C. CONTINUOUS SEALANT AT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER USE NAILS PER TREATED MANUFACTURERS SILL PLATE RECOMMENDATIONS FOR SIZE AND SPACING CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE-TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES CONCRETE OR MASONRY FOUNDATION WALL ANCHOR BOLT AS REQUIRED BY CODE FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL C Fig. 5 FINISH ROOFING MATERIAL ROOFING FELT 8d COMMON FOAM RIDGE CAP NAILS @ 6" O.C. BOTH SIDES SIP ROOF PANEL CONTINUOUS SEALANT EACH SIDE OF FRAMING AND BOTH FACES AS RECOMMENDED BY MANUFACTURER SEALANT AS RECOMMENDED BY MANUFACTURER SIPS SCREWS WITH 1" MIN. PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED DRYWALL STRUCTURAL SUPPORT MEMBER WITH CONTINUOUS FIELD MIN. 1-1/2" BEARING FOR EACH SIDE OF INSTALLED WOOD PANELS RIDGE SUPPORT BEAM SHOWN ROOF-TO-ROOF PANEL CONNECTIONS FOAM RIDGE CAP DETAIL Fig. 6 MINIMUM 3/8" GAP FOR SEALANT AS FINISHED RECOMMENDED BY ROOFING MATERIAL MANUFACTURER ROOFING BLOCKING AS REQUIRED FELT BY STRUCTURAL CONDITIONS SIPS SCREWS W/ MINIMUM 1" PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED RIDGE SUPPORT BEAM ROOF-TO-ROOF PANEL CONNECTIONS BEVELED SIP RIDGE DETAIL Fig. 7 PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT SIP ROOF PANEL 8d COMMON NAILS @ 6" O.C. EACH SIDE CONTINUOUS SEALANT EACH SIDE OF FRAMING AS RECOMMENDED BY MANUFACTURER, AND ROOF PANEL 2x JOINT TOP PLATE DRYWALL SIP WALL PANEL DRAINED AND VENTILATED CLADDING ROOF-TO-WALL PANEL CONNECTIONS BEVELED SIP WALL Fig. 8 WEDGE INFILL PIECE PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT CONTINUOUS SEALANT EACH SIDE SIP ROOF OF FRAMING AS RECOMMENDED BY PANEL MANUFACTURER CONTINUOUS SEALANT EACH SIDE OF FRAMING, 8d COMMON NAILS AND ROOF PANEL @ 6" O.C. BOTH SIDES 2x JOINT TOP PLATE DRYWALL CONTINUOUS SEALANT EACH SIDE SIP WALL PANEL OF FRAMING AS RECOMMENDED BY MANUFACTURER DRAINED AND VENTILATED CLADDING ROOF-TO-WALL PANEL CONNECTIONS WEDGE INFILL PIECE Fig. 10 8d COMMON NAILS 6" O.C. BOTH SIDES CONTINUOUS SEALANT BOTH SIDES TYP. OF FRAMING AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT TYPICAL AS RECOMMENDED BY MANUFACTURER 16d COMMON NAILS @ 16" O.C. FINISHED ROOFING MATERIAL ROOFING FELT SIP TAPE AT RIDGE REQUIRED ROOF-TO-ROOF PANEL CONNECTIONS RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG) Fig. 11 SECOND FLOOR DRYWALL SIP WALL PANEL STANDARD WIRE CHASE 16d COMMON NAILS @ 16" O.C. WHEN USED AS BRACING (3) 16d COMMON NAILS @ 16" O.C. DRAINED AND CONTINUOUS SEALANT EACH SIDE OF VENTILATED FRAMING TYP. AS RECOMMENDED BY CLADDING MANUFACTURER 2x BOTTOM PLATE 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND 8d COMMON OVER TOP OF SIP WALL NAILS @ 6" O.C. BOTH SIDES FLOOR JOISTS METAL STRAP AS REQUIRED OR LTP4 SIMPSON CLIP CAP PLATE CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER TOP FLANGE METAL FLOOR JOIST HANGAR (BY OTHERS) FIRST FLOOR DRYWALL 2ND FLOOR CONNECTION DETAILS HANGING FLOOR Fig. 12 SECOND FLOOR DRYWALL SIP WALL PANEL STANDARD WIRE CHASE 16d COMMON NAILS @ 16" O.C. DRAINED AND WHEN USED AS BRACING (3) 16d VENTILATED COMMON NAILS @ 16" O.C. CLADDING 2x BOTTOM INSULATION PLATE 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND 8d COMMON OVER TOP OF SIP WALL NAILS @ 6" O.C. BOTH SIDES FLOOR JOISTS (I-JOIST SHOWN) METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD RIM BOARD METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD FIRST FLOOR CONTINUOUS SEALANT EACH SIDE OF 8d COMMON FRAMING TYP. AS RECOMMENDED BY NAILS @ 6" O.C. MANUFACTURER BOTH SIDES CAP PLATE AS REQUIRED BY MANUFACTURER DRYWALL CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER 2ND FLOOR CONNECTION DETAILS RIM BOARD Fig. 13 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE DRIP EDGE FLASHING FASCIA SOFFIT BOARD EAVES DETAILING EAVES DETAIL A Fig. 14 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER DRIP EDGE CONTINUOUS SEALANT AS FLASHING RECOMMENDED BY MANUFACTURER ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE 2X BLOCKING TO SUPPORT 8d COMMON NAILS FASCIA BOARD @ 6" O.C. BOTH SIDES 2x FRAMING MEMBER FASCIA SIP SCREW SOFFIT BOARD EAVES DETAILING EAVES DETAIL B Fig. 15 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. RECOMMENDED BY DRIP EDGE USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. 2x FRAMING MEMBER CONTINUOUS SEALANT RECOMMENDED BY 2x FRAMING MEMBER MANUFACTURER 8d COMMON NAILS @ 6" O.C. BOTH SIDES FASCIA SOFFIT BOARD SIP SCREW EAVES DETAILING EAVES DETAIL C Fig. 16 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER DRIP EDGE FLASHING 8d COMMON NAILS @ 6" O.C. BOTH SIDES CONTINUOUS SEALANT BEVELED AS RECOMMENDED BY BLOCKING MANUFACTURER TO SUPPORT FASCIA BOARD ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. EAVES DETAILING EAVES DETAIL D Fig. 17 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY DRIP EDGE 8d COMMON NAILS @ 6" O.C. BOTH SIDES CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. FASCIA SOFFIT BOARD EAVES DETAILING EAVES DETAIL E Fig. 18 CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS SEALANT AS RECOMMENDED @ 6" O.C. EACH STRIP BY MANUFACTURER AND EACH SIDE CHASE FOR EXPANDED FOAM SEALANT WALL-TO-WALL VERTICAL PANEL CONNECTIONS SURFACE SPLINE FOR VERTICAL SPLICE Fig. 19 2x FRAMING AROUND WINDOWS AND DOOR OPENINGS DOOR AND WINDOW FRAMING Fig. 21 (2) ROWS 16d COMMON NAILS@ 16" O.C. MINIMUM SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS CONTINUOUS SEALANT EACH @ 6" O.C. EACH PANEL SIDE OF FRAMING TYP. AS AND EACH SIDE RECOMMENDED BY MANUFACTURER WALL-TO-WALL VERTICAL PANEL CONNECTIONS DIMENSIONAL LUMBER SPLINE Fig. 20 CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED DOUBLE 2x SPLINE BY MANUFACTURER VALLEY BEVEL CUT FLASHING SIP ROOF PANEL 16d COMMON NAILS @ 16" SIPS SCREW SIP TAPE O.C. MINIMUM W/ MINIMUM 1" 8d COMMON NAILS @ PENETRATION 6" O.C. EACH PANEL INTO STRUCTURAL AND EACH SIDE SUPPORT CONTINUOUS SEALANT STRUCTURAL SUPPORT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY DRYWALL MANUFACTURER AT SUPPORT MEMBERS ROOF-TO-ROOF PANEL CONNECTIONS VALLEY DETAIL Fig. 22 SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS CONTINUOUS SEALANT @ 6" O.C. EACH PANEL EACH SIDE OF FRAMING TYP. AND EACH SIDE AS RECOMMENDED BY MANUFACTURER BLOCK SPLINE WALL-TO-WALL VERTICAL PANEL CONNECTIONS BLOCK SPLINE Fig. 23.