SIP Roofing Panel Connection Diagrams SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. FOAM AS RECOMMENDED CORE BY MANUFACTURER DRYWALL CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED 8d COMMON NAILS BY MANUFACTURER @ 6" O.C. EACH SIDE WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION Fig. 2 DRYWALL SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT SIP WALL DRAINED AND VENTILATED CLADDING FLOOR JOIST FIELD INSTALLED PANEL BOTTOM PLATE 16d NAILS INTO SILL PLATE @ 16" O.C. 8d COMMON NAILS @ 6" O.C. BOTH SIDES TREATED SILL PLATE BE SURE OUTSIDE SILL SEALER SKIN IS SUPPORTED BY SILL PLATE TERMITE SHIELD CONCRETE CONTINUOUS SEALANT EACH SIDE OF OR MASONRY FRAMING TYP. AS RECOMMENDED BY FOUNDATION MANUFACTURER WALL MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS @ 6 FEET O.C. MAXIMUM FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL A Fig. 3 SIP WALL DRAINED AND VENTILATED CLADDING DRYWALL CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER FIELD INSTALLED 8d COMMON NAILS @ 6" TREATED BOTTOM O.C. EACH SIDE PLATE CAPILLARY BREAK, MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS MIN. 6 MIL POLY OR @ 6 FEET O.C. MAXIMUM MIN. 3/4" PRESSURE- TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES TERMITE SHIELD CONCRETE OR MASONRY FOUNDATION WALL FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL B Fig. 4 SIP WALL DRAINED AND VENTILATED CLADDING DRYWALL FIELD INSTALLED TREATED BOTTOM PLATE 8d COMMON SUBFLOOR OR COMBINED SUBFLOOR NAILS @ 6" AND UNDERLAYMENT, TYP. O.C. EACH SIDE FLOOR JOIST 16d NAILS INTO FLOOR JOIST PLATE @ 16" O.C. WHEN USED AS BRACING (3) 16d @ 16” O.C. CONTINUOUS SEALANT AT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER USE NAILS PER TREATED MANUFACTURERS SILL PLATE RECOMMENDATIONS FOR SIZE AND SPACING CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE-TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES CONCRETE OR MASONRY FOUNDATION WALL ANCHOR BOLT AS REQUIRED BY CODE FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL C Fig. 5 FINISH ROOFING MATERIAL ROOFING FELT 8d COMMON FOAM RIDGE CAP NAILS @ 6" O.C. BOTH SIDES SIP ROOF PANEL CONTINUOUS SEALANT EACH SIDE OF FRAMING AND BOTH FACES AS RECOMMENDED BY MANUFACTURER SEALANT AS RECOMMENDED BY MANUFACTURER SIPS SCREWS WITH 1" MIN. PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED DRYWALL STRUCTURAL SUPPORT MEMBER WITH CONTINUOUS FIELD MIN. 1-1/2" BEARING FOR EACH SIDE OF INSTALLED WOOD PANELS RIDGE SUPPORT BEAM SHOWN ROOF-TO-ROOF PANEL CONNECTIONS FOAM RIDGE CAP DETAIL Fig. 6 MINIMUM 3/8" GAP FOR SEALANT AS FINISHED RECOMMENDED BY ROOFING MATERIAL MANUFACTURER ROOFING BLOCKING AS REQUIRED FELT BY STRUCTURAL CONDITIONS SIPS SCREWS W/ MINIMUM 1" PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED RIDGE SUPPORT BEAM ROOF-TO-ROOF PANEL CONNECTIONS BEVELED SIP RIDGE DETAIL Fig. 7 PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT SIP ROOF PANEL 8d COMMON NAILS @ 6" O.C. EACH SIDE CONTINUOUS SEALANT EACH SIDE OF FRAMING AS RECOMMENDED BY MANUFACTURER, AND ROOF PANEL 2x JOINT TOP PLATE DRYWALL SIP WALL PANEL DRAINED AND VENTILATED CLADDING ROOF-TO-WALL PANEL CONNECTIONS BEVELED SIP WALL Fig. 8 WEDGE INFILL PIECE PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT CONTINUOUS SEALANT EACH SIDE SIP ROOF OF FRAMING AS RECOMMENDED BY PANEL MANUFACTURER CONTINUOUS SEALANT EACH SIDE OF FRAMING, 8d COMMON NAILS AND ROOF PANEL @ 6" O.C. BOTH SIDES 2x JOINT TOP PLATE DRYWALL CONTINUOUS SEALANT EACH SIDE SIP WALL PANEL OF FRAMING AS RECOMMENDED BY MANUFACTURER DRAINED AND VENTILATED CLADDING ROOF-TO-WALL PANEL CONNECTIONS WEDGE INFILL PIECE Fig. 10 8d COMMON NAILS 6" O.C. BOTH SIDES CONTINUOUS SEALANT BOTH SIDES TYP. OF FRAMING AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT TYPICAL AS RECOMMENDED BY MANUFACTURER 16d COMMON NAILS @ 16" O.C. FINISHED ROOFING MATERIAL ROOFING FELT SIP TAPE AT RIDGE REQUIRED ROOF-TO-ROOF PANEL CONNECTIONS RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG) Fig. 11 SECOND FLOOR DRYWALL SIP WALL PANEL STANDARD WIRE CHASE 16d COMMON NAILS @ 16" O.C. WHEN USED AS BRACING (3) 16d COMMON NAILS @ 16" O.C. DRAINED AND CONTINUOUS SEALANT EACH SIDE OF VENTILATED FRAMING TYP. AS RECOMMENDED BY CLADDING MANUFACTURER 2x BOTTOM PLATE 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND 8d COMMON OVER TOP OF SIP WALL NAILS @ 6" O.C. BOTH SIDES FLOOR JOISTS METAL STRAP AS REQUIRED OR LTP4 SIMPSON CLIP CAP PLATE CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER TOP FLANGE METAL FLOOR JOIST HANGAR (BY OTHERS) FIRST FLOOR DRYWALL 2ND FLOOR CONNECTION DETAILS HANGING FLOOR Fig. 12 SECOND FLOOR DRYWALL SIP WALL PANEL STANDARD WIRE CHASE 16d COMMON NAILS @ 16" O.C. DRAINED AND WHEN USED AS BRACING (3) 16d VENTILATED COMMON NAILS @ 16" O.C. CLADDING 2x BOTTOM INSULATION PLATE 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND 8d COMMON OVER TOP OF SIP WALL NAILS @ 6" O.C. BOTH SIDES FLOOR JOISTS (I-JOIST SHOWN) METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD RIM BOARD METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD FIRST FLOOR CONTINUOUS SEALANT EACH SIDE OF 8d COMMON FRAMING TYP. AS RECOMMENDED BY NAILS @ 6" O.C. MANUFACTURER BOTH SIDES CAP PLATE AS REQUIRED BY MANUFACTURER DRYWALL CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER 2ND FLOOR CONNECTION DETAILS RIM BOARD Fig. 13 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE DRIP EDGE FLASHING FASCIA SOFFIT BOARD EAVES DETAILING EAVES DETAIL A Fig. 14 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER DRIP EDGE CONTINUOUS SEALANT AS FLASHING RECOMMENDED BY MANUFACTURER ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE 2X BLOCKING TO SUPPORT 8d COMMON NAILS FASCIA BOARD @ 6" O.C. BOTH SIDES 2x FRAMING MEMBER FASCIA SIP SCREW SOFFIT BOARD EAVES DETAILING EAVES DETAIL B Fig. 15 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. RECOMMENDED BY DRIP EDGE USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. 2x FRAMING MEMBER CONTINUOUS SEALANT RECOMMENDED BY 2x FRAMING MEMBER MANUFACTURER 8d COMMON NAILS @ 6" O.C. BOTH SIDES FASCIA SOFFIT BOARD SIP SCREW EAVES DETAILING EAVES DETAIL C Fig. 16 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER DRIP EDGE FLASHING 8d COMMON NAILS @ 6" O.C. BOTH SIDES CONTINUOUS SEALANT BEVELED AS RECOMMENDED BY BLOCKING MANUFACTURER TO SUPPORT FASCIA BOARD ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. EAVES DETAILING EAVES DETAIL D Fig. 17 ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY DRIP EDGE 8d COMMON NAILS @ 6" O.C. BOTH SIDES CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. FASCIA SOFFIT BOARD EAVES DETAILING EAVES DETAIL E Fig. 18 CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS SEALANT AS RECOMMENDED @ 6" O.C. EACH STRIP BY MANUFACTURER AND EACH SIDE CHASE FOR EXPANDED FOAM SEALANT WALL-TO-WALL VERTICAL PANEL CONNECTIONS SURFACE SPLINE FOR VERTICAL SPLICE Fig. 19 2x FRAMING AROUND WINDOWS AND DOOR OPENINGS DOOR AND WINDOW FRAMING Fig. 21 (2) ROWS 16d COMMON NAILS@ 16" O.C. MINIMUM SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS CONTINUOUS SEALANT EACH @ 6" O.C. EACH PANEL SIDE OF FRAMING TYP. AS AND EACH SIDE RECOMMENDED BY MANUFACTURER WALL-TO-WALL VERTICAL PANEL CONNECTIONS DIMENSIONAL LUMBER SPLINE Fig. 20 CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED DOUBLE 2x SPLINE BY MANUFACTURER VALLEY BEVEL CUT FLASHING SIP ROOF PANEL 16d COMMON NAILS @ 16" SIPS SCREW SIP TAPE O.C. MINIMUM W/ MINIMUM 1" 8d COMMON NAILS @ PENETRATION 6" O.C. EACH PANEL INTO STRUCTURAL AND EACH SIDE SUPPORT CONTINUOUS SEALANT STRUCTURAL SUPPORT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY DRYWALL MANUFACTURER AT SUPPORT MEMBERS ROOF-TO-ROOF PANEL CONNECTIONS VALLEY DETAIL Fig. 22 SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS CONTINUOUS SEALANT @ 6" O.C. EACH PANEL EACH SIDE OF FRAMING TYP. AND EACH SIDE AS RECOMMENDED BY MANUFACTURER BLOCK SPLINE WALL-TO-WALL VERTICAL PANEL CONNECTIONS BLOCK SPLINE Fig. 23.
Recommended publications
  • FLASHING Residential Brick Veneer
    FLASHING residential brick veneer To avoid water-penetration problems, provide adequate drainage details above and below openings and at the base of the wall By Walter Laska he most common masonry wall system in residential con- Tstruction is brick veneer. All brick veneer walls are drainage w a l l s . T h e i r d e s i g n s h o u l d b e based on the premise that water is going to enter into the wall sys- t e m .T h e re f o re ,t oe n s u re t h ew a l l ’s successful performance, the wall design must incorporate a means for water egress. Drainage space The first requirement for a brick veneer wall is a functional drain- age space. A minimum 1 inch of air space, clear of mortar bridg- ing, should be indicated on the drawings. If possible, design the 1 wall system with a 1 ⁄2- to 2-inch air space. A narrow air space can- not be kept clear of mortar extru- sions and mortar droppings. Fur- thermore, it is impossible for a Figure 1. Although brick veneer walls normally require a 1-inch minimum air mason to remove mortar from a space behind the brick, a new insulation and drainage board material used narrow air space with his trowel, in place of the usual sheathing and building wrap allows water to drain without knocking the brick out of without an open space. The vertical leg of the base flashing should be placed behind this material.
    [Show full text]
  • Sill Retrofit Connector Plate SRCP
    Sill Retrofit Connector Plate SRCP F Figure 1 F2 1 USP's SRCP Sill Retrofit Connector Plate is designed as a 11" F3 retrofit sill-to-foundation connection that can be installed Sill plate F1 where there is minimal space between the floor framing Foundation wall and top of the foundation wall. The economical design is 6" targeted for use in seismic regions and yet is also suitable for use as a supplementary connection in high wind areas. USP WS3 screw The SRCP Sill Retrofit Connector Plate can be installed SRCP plate without shims anywhere the face of the sill plate is within 1/2" max SRCP without shim ½" 0/ Post-installed 1/2" of the face of the foundation wall. concrete/masonry anchor Features: Typical SRCP installation • The flat plate design works without suplemental without shim, 1/2" max setback washers at the anchor bolts Figure 1 • Works with 2x solid-sawn sill plates or larger F2 F1 • Easy access to the hex head of the WS3 screws F F simplifies installation Sill plate 1 3 • Accommodates sill plate setbacks and overhangs Foundation wall of up to 1/2" without the use of shims • WS3 wood screws are provided with each connector USP WS3 screw 1/2" max SRCP plate Materials: 10 gauge ½" 0/ Post-installed concrete/masonry anchor Finish: G90 galvanizing Codes: ICC-ES ESR-3455, FL17244, COLA RR 25745 Typical SRCP installation without shim, 1/2" max overhang Installation: • For sill plate setbacks from 1/2" to 1-1/2", install a wood shim Figure 2 (a minimum of 15" long) tight against the sill plate and flush F with the foundation wall.
    [Show full text]
  • Dry Dock Bid Spec
    WHATCOM COUNTY FINANCE/ACCOUNTING ADMINISTRATIVE SERVICES Whatcom County Courthouse 311 Grand Avenue, Suite #503 Bellingham WA 98225-4082 Brad Bennett, Finance Manager June 12, 2020 ADDENDUM #1 Bid #20-22 2020 Drydocking, Repair & Maintenance of the Whatcom Chief Ferry ATTENTION ALL BIDDERS & DOCUMENT HOLDERS This Addendum 1 consists of a total of 25 pages, including this page. Bid opening date and time shall remain the same: 2:30 PM, Tuesday, June 23, 2020. The bid documents have been amended as follows. The following changes are hereby made part of the contract documents and plans. NOTE: Bidders are required to acknowledge receipt of this addendum on page 18 of the Bid Response Forms for the bid proposal to be considered complete. Failure to acknowledge receipt of the Addendum may become cause for rejection of the Bid. The following changes are as a result of the mandatory “virtual” pre-bid meeting held onboard the Whatcom Chief on Thursday, May 21, 2020 and questions received to date. PART II- BID PROPOSAL Please ADD the following after page 13 of 64: Page 1 of 25 Addendum 1 – Whatcom County Bid #20-22 ALTERNATE BID PROPOSAL #1- DOCKSIDE @ SHIPYARD 2020 DRYDOCKING, REPAIR, AND MAINTENANCE OF THE WHATCOM CHIEF ITEM NO. QUANTITY ITEM & WRITTEN UNIT PRICE UNIT PRICE TOTAL 1. LUMP SUM DRYDOCK VESSEL / MISC. ITEMS Dollars L.S. $ (Written Lump Sum Price) 2. LUMP SUM INTERNAL COMPARTMENTS Dollars L.S. $ (Written Lump Sum Price) 3. LUMP SUM CLEAN & PAINT SEA VALVES Dollars L.S. $ (Written Lump Sum Price) 4. LUMP SUM REPLACE ALL ZINCS Dollars L.S.
    [Show full text]
  • Building for High Wind Resistance in Light-Frame Wood Construction
    Building for High Wind Resistance in Light-Frame Wood Construction DESIGN GUIDE Building for High Wind Resistance in Light-Frame Wood Construction Meeting the Challenge of High Wind Design Designing a structure to withstand the devastating forces of tornados is one of the greatest challenges a builder can face. There is a common myth that all tornados are so strong that structural failure is imminent, no matter how well a building is constructed. The fact is, weaker tornados rated as EF-0, EF-1 and EF-2 by the National Weather Service statistically comprise 95 percent of all tornados. A home that is carefully constructed, in accordance with current building codes, can withstand these smaller, less violent storms. Stronger tornados rating EF-3, EF-4 and EF-5 are much less common. While it is more difficult for homes to survive these storms, good design details can make a difference, particularly when the structure is located along the outer reaches of the area influenced by the vortex of the storm. The design and construction recommendations in this guide from APA contribute to improved overall performance in the structural shell and focus on good connection details to tie together exterior walls, roofs, and floors. Some of these design recommendations exceed the minimum code requirements and typical APA recommendations. These recommendations are intended for new construction only, although the principles may be appropriate for retrofit applications. The recommendations in this publication may not be appropriate for hurricane- prone regions. In those regions, local building code requirements must be followed. Whether caused by a tornado or severe wind storm, high wind forces follow the load path of a structure.
    [Show full text]
  • Raised Wood Floor Foundations Design & Construction Guide
    RAISED WOOD FLOOR FOUNDATIONS DESIGN & CONSTRUCTION GUIDE RaisedFloorLiving.com Building to a Higher Standard Satisfying the higher expectations of today’s The Raised Wood Floor Process homebuyer presents new challenges. Meeting these challenges begins with a raised wood ING S TT TA floor foundation that enhances curb appeal E R G T and provides many other benefits. E D With raised wood floor foundations, P building professionals stay… A GE1 3 SITE CONDITIONS SOIL PROPERTIES Noticed. Builders of raised wood floor homes distinguish themselves from the competition PIER AND BEAM NDATIO by establishing a reputation for being green OU N and progressive. F S Competitive. The aesthetics and amenities of raised floor P A homes make a positive impression on G2E homebuyers, which may result in faster, 4 WOOD PILING MASONRY PIER more profitable sales. A raised wood floor CONTINUOUS STEMWALL foundation can also be the cost-competitive solution, especially in locations with elevation requirements, problematic soils, sloping terrain or where extensive site preparation is needed. On Schedule. WOOD MASONRY Lengthy concrete slab delays – due to poor weather, time-consuming forming and curing, trade scheduling problems, extra inspections, R F GIRDERS or hauling and compacting of fill dirt – can be OO RA FL M avoided with raised wood floor foundations. I N G On The Upgrade. Homebuyers appreciate features of a raised P A foundation – a front porch, screened back G E3 porch or sunroom, or a backyard deck. 9 GLULAM LUMBER Building professionals who elevate with raised JOISTS floors framed with strong, renewable wood products create value for themselves and their clients.
    [Show full text]
  • Wood-Frame House Construction
    WOOD-FRAME HOUSE CONSTRUCTION U.S. DEPARTMENT OF AGRICULTURE «FOREST SERVICB»AGRICULTURE HANDBOOK NO. 73 WOOD-FRAME HOUSE CONSTRUCTION By L. O. ANDERSON, Engineer Forest Products Laboratory — Forest Service U. S. DEPARTMENT OF AGRICULTURE Agriculture Handbook No. 73 • Revised July 1970 Slightly revised April 1975 For sale by the Superintendent of Documents, U.S. Government Printing Office, Washincfton, D.C. 20402 Price: $2.60 ACKNOWLEDGMENT Acknowledgment is made to the following members of the Forest Products Laboratory (FPL) for their contributions to this Handbook: John M. Black, for information on painting and finishing; Theodore C. Scheffer, for information on protection against termites and decay; and Herbert W. Eickner, for information on protection against fire. Acknowledgment is also made to Otto C. Heyer (retired) for his part as a co-author of the first edition and to other FPL staff members who have contributed valuable information for this revision. The wood industry has also contributed significantly to many sections of the publication. 11 CONTENTS Page Page Introduction 1 Chapter 6.—Wall Framing 31 Requirements 31 Chapter 1.—Location and Excavation 1 Platform Construction 31 Condition at Site 1 Balloon Construction 33 Placement of the House 3 Window and Door Framing 34 Height of Foundation Walls 3 End-wall Framing 36 Excavation 4 Interior Walls 38 Chapter 2.—Concrete and Masonry 5 Lath Nailers 39 Mixing and Pouring 5 Chapter 7.—Ceiling and Roof Framing 40 Footings 5 Ceiling Joists 40 Draintile 7 Flush Ceiling Framing 42
    [Show full text]
  • Builder Guideline Booklet (Revised June 2018) and the 2018 International Residential Code
    FRAMER’S CHECKLIST Rev: 06/2018 For use by framing contractors to ensure proper framing connection to top of Superior Walls panels. All page references made below use the Superior Walls of America Builder Guideline Booklet (Revised June 2018) and the 2018 International Residential Code. Additional copies of this checklist are available for download at www.superiorwalls.com. 1. Builder Guideline Booklet  Obtain your personal copy of the Builder Guideline Booklet 2. Building drawings  Confi rm you are working from the approved drawing  Drawing date:____________ Drawing Rev:_______________ 3. Crawl space (Pg. 20 & 21): Confi rm, with builder, one of the following: For additional technical information,  2” minimum poured concrete fl oor please see the Technical Resources  12” minimum inside fi ll section of our website:  Treated wooden bracing at 48” O.C. www.superiorwalls.com/tech_resources 4. Sill plate framing connection (Pg. 24 to 27)  Obtain sill plate bolting frequency from builder (Table #3 on page 27) (__24” OC or ___ 48” OC)  ½” bolts/studs with washers used to attach the sill plate to the top bond beam  Fastened above window & door headers (Pg. 24)  A minimum of 2 bolts/studs per sill plate section  Bolted within 12” of the ends of each sill plate section (R403.1.6)  Sill plate splices are at least 48” from any foundation panel joint  Bolted in center 1/3 of Plate 5. Perpendicular fl oor joist connection (Pg. 24)  Each joist nailed to sill plate with two 16d common nails (3-1/2” x 0.162”) (or according to code) 6.
    [Show full text]
  • Written Historical and Descriptive Data Reduced
    BELLMAWR PARK MUTUAL HOUSING CORPORATION, 38 & 40 HABS NJ-1264-C VICTORY DRIVE HABS NJ-1264-C 38 & 40 Victory Drive Bellmawr Camden County New Jersey WRITTEN HISTORICAL AND DESCRIPTIVE DATA REDUCED COPIES OF MEASURED DRAWINGS HISTORIC AMERICAN BUILDINGS SURVEY National Park Service U.S. Department of the Interior 1849 C Street NW Washington, DC 20240-0001 HISTORIC AMERICAN BUILDINGS SURVEY BELLMAWR PARK MUTUAL HOUSING CORPORATION, 38 & 40 VICTORY DRIVE HABS No.: NJ-1264-C Location: 38 & 40 Victory Drive, Bellmawr, Camden County, New Jersey The building is located at latitude: 39.870237, longitude: -75.102695. This point was obtained on July 22, 2016, using Google Earth (WGS84). There is no restriction on its release to the public. Present Owner: Bellmawr Park Mutual Housing Corporation 31 Peach Road, Bellmawr, New Jersey 08031 Significance: Bellmawr Park was constructed in 1941 and consisted of 500 units, as part of a joint federal program with the Congress of Industrial Organizations for workers at local shipyards who could not afford to buy homes. The community, along with Audubon Park and Pennypack Woods in Northeast Philadelphia, were also testing sites for "mutual," or cooperative home ownership and new concepts in community planning, modern architecture and mass-produced housing. Description: 38 & 40 Victory Drive is a single story, vernacular duplex in a minimalist ranch style house design. The living units are one story, vinyl siding, wood framed construction over a crawl space with masonry walls, block piers and wood girder to support the wood floor framing. Living units are symmetrical and are comprised of a living room, kitchen/dining area, bedroom(s) with closet(s), a bathroom, linen and storage closets, and utility room.
    [Show full text]
  • Wood Framed Shear Wall Inspection Checklist
    Wood Framed Shear Wall Inspection Checklist City of Rancho Palos Verdes Community Development Department This list comprises some of the common code violations when installing wood framed shear wall. It does not address every possible violation, nor is it intended as an instruction manual. 9 Verify with City approved stamped structural framing plans and architectural floor plans, the location and length of all shear walls to be installed. 9 Verify the nailing of the sheathing agrees with the shear wall schedule. 9 Nail Type i.e. common, galvanized box. 9 Nail Diameter 8d or 10d etc. 9 Nail Length (minimum penetration into framing 12 times nail diameter), and Spacing along each edge of each piece of Sheathing (6", 4", 3", etc.). 9 Nail Head Shape (clipped heads not permitted). 9 Nail Placement: ¾ Driven flush but not overdriven. ¾ Minimum 3/8" from sheathing edge to center of nail. ¾ View the stud side to check for nails that missed framing. ¾ Staggered along edges where spacing is 3 inches o.c. or less. ¾ Edge nails into hold-down post. 9 Verify sheathing material agrees with the structural notes and: ¾ Type (Plywood or OSB); Grade (APA Rated Panel or APA Rated Panel-Structural 1). ¾ Thickness (3/8, 15/32 ) ; Number of Ply’s (if specified for plywood). 9 Verify lumber size and grade agrees with the structural notes. 9 Framing Grade of Studs & Posts (Stud, Construction, No. 2, and No. 1). 9 Lumber Species (Douglas Fir Larch, Hem-Fir). 9 Framing Size (3x studs, sill at heavily nailed edges, 2-2x, 4x or 6x at HD).
    [Show full text]
  • Framing & Building Basics
    Framing & Building Basics Architectural Drawing & Interior Design Introduction to Framing • Once you have your floor plan design, you are now ready to plan for building. • In order to accomplish this, you must know the correct methods needed to properly frame a house. • While this can get extremely daunting in larger homes, in tiny houses it is much simpler. Structural Loads • Before we get started with framing we understand structural loads. • Structural loads are forces that get to applied to structures, e.g. wind, gravity, snow, earthquakes, people etc. • If your house cannot handle such loads your building(s) will collapse. • Structural Loads include dead loads, live loads, environmental loads. Structural Loads • A dead load is the actual weight of the materials used in the construction of the house, e.g. walls, floors, roofs. Fixed and considered permanent. • Live load’s are produced by the use and the occupancy of the building, e.g. people and furnishings. Variable and temporary. • Deflection is the bounce or give in a floor system as a person walks across a room. The stiffer the material the less deflection Wind Load • Lateral pressure may be positive (pushing) or negative (suction forces on the leeward side). • Wind pressure can also produce uplift. Hurricanes • Hurricane prone areas are the coastal areas of the Atlantic Ocean and the Gulf of Mexico where wind speed exceeds 90 mph. • Additional protection is required for exterior glazing where wind blown debris might be a problem. Snow • The IRC (International Residential Code) specifies that the snow load for the roof of a house must support 70 psf.
    [Show full text]
  • Shear Wall Sill Plate Behavior in Wood Frames
    SHEAR WALL SILL PLATE BEHAVIOR IN WOOD FRAMES By SAYED MASEEH REZAZADAH Bachelor of Science in Civil Engineering Kabul University Kabul, Afghanistan 2011 Submitted to the Faculty of the Graduate College of the Oklahoma State University in partial fulfillment of the requirements for the Degree of MASTER OF SCIENCE July 2015 SHEAR WALL SILL PLATE BEHAVIOUR IN WOOD FRAMES Thesis Approved: Dr. Robert Emerson Thesis Adviser Dr. M. Tyler Ley Dr. Michael Phil Lewis ii ACKNOWLEDGEMENTS First and foremost I would like to thank my adviser Dr. Robert N. Emerson for his great support during my graduate studies at the Oklahoma State University. His courage and support helped me to complete this research. I do appreciate his effort in helping me with testing materials as well lab works. I would like to thank Dr. M. Tyler Ley and Dr. Michael Phil Lewis for their support and time reviewing, guiding and helping me to make this report better. I take the chance to thank the Fulbright program for giving me the chance to study in the United States and support me during my graduate studies. Many thanks to my family for their support as they always did in every stage of my life. Sayed Maseeh Rezazadah, July, 2015 Oklahoma State University Stillwater, United States Acknowledgements reflect the views of the author and are not endorsed by committee members or Oklahoma State University. iii Name: SAYED MASEEH REZAZADAH Date of Degree: JULY, 2015 Title of Study: SHEAR WALL SILL PLATE BEHAVIOR IN WOOD FRAMES Major Field: CIVIL ENGINEERING Abstract: In the Midwest region of United States of America tornados are considered to be the most brutal form of natural disaster for the building houses where many of these houses are built out of wood.
    [Show full text]
  • Sill Retrofit Connector SRC
    Sill Retrofit Connector SRC The SRC Sill Retrofit Connector has been engineered as a ductile retrofit for older buildings in high seismic zone regions that require additional reinforcement. It can be installed where there is minimal space between the floor framing and top of the foundation wall. The SRC can also be used to reinforce buildings in high velocity wind zones. The two-piece design easily adjusts to foundations of varying thickness and can also be used where the sill plate may not be parallel to the face of the foundation wall. Features: • The flat plate design works without supplemental washers at the anchor bolts • Works with 2x solid-sawn sill plates or larger • Accommodates sill plate setbacks up to 2-1/2" and foundation walls with a sloped face up to 20 degrees. • Easy access to the hex head of the WS6 screws simplifies installation Materials: Channel - 12 gauge, Plate - 10 gauge Finish: G90 galvanizing F1 SRC channel Codes: ICC-ES ESR-3455, FL17244, LA RR 25745 F1 SRC Channel Sill plate Installation: Sill plate • Use all specified fasteners. USP WS6 screw USP WS6 screw • WS6 wood screws are supplied SRC Plate SRC Plate with each SRC connector. 2-1/2" 2-1/2" Max Max • Contact Customer Service 1/2"Ø Post-Installed 1/2"Ø Post-Installed concrete/masonry concrete/masonry for offsets more than 2-1/2". anchor 20° anchor Max Foundation wall Foundation wall Typical SRC installation Typical SRC installation on rectangular foundation on trapezoidal foundation Recommended Installation Sequence 2-1/2" 11" 1-1/4" 6" 11" SRC components 1) Install 5 - WS6 screws 2) Drill and install concrete anchors Dimensions (in) Maximum Fastener Schedule Allowable Load (Lbs.)1 Spacing to Concrete3,4 Sill Plate2 DF/SP Replace USP Steel 1/2" or 5/8" F1 (Parallel to Plate) Ctn Stock No.
    [Show full text]