SIPS WITH MINIMUM 1" PENETRATION IN MEMBER IN SIP PANEL CONNECTED TO @ 24" O.C. MAXIMUM

OUTSIDE SKIN

CONTINUOUS SEALANT EACH SIDE OF TYP. FOAM AS RECOMMENDED CORE BY MANUFACTURER

DRYWALL

CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED 8d COMMON NAILS BY MANUFACTURER @ 6" O.C. EACH SIDE

WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 DRYWALL SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT SIP WALL

DRAINED AND VENTILATED CLADDING FLOOR

FIELD INSTALLED PANEL BOTTOM PLATE

16d NAILS INTO SILL PLATE @ 16" O.C. 8d COMMON NAILS @ 6" O.C. BOTH SIDES

TREATED SILL PLATE BE SURE OUTSIDE SILL SEALER SKIN IS SUPPORTED BY SILL PLATE TERMITE SHIELD

CONCRETE CONTINUOUS SEALANT EACH SIDE OF OR MASONRY FRAMING TYP. AS RECOMMENDED BY FOUNDATION MANUFACTURER WALL MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS @ 6 FEET O.C. MAXIMUM

FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL A

Fig. 3 SIP WALL

DRAINED AND VENTILATED CLADDING DRYWALL

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

FIELD INSTALLED 8d COMMON NAILS @ 6" TREATED BOTTOM O.C. EACH SIDE PLATE CAPILLARY BREAK, MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS MIN. 6 MIL POLY OR @ 6 FEET O.C. MAXIMUM MIN. 3/4" PRESSURE- TREATED UNDER SILL PLATE AND BOTH FACES TERMITE SHIELD

CONCRETE OR MASONRY FOUNDATION WALL FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL B

Fig. 4 SIP WALL

DRAINED AND VENTILATED CLADDING

DRYWALL

FIELD INSTALLED TREATED BOTTOM PLATE

8d COMMON SUBFLOOR OR COMBINED SUBFLOOR NAILS @ 6" AND UNDERLAYMENT, TYP. O.C. EACH SIDE FLOOR JOIST

16d NAILS INTO FLOOR JOIST PLATE @ 16" O.C. WHEN USED AS BRACING (3) 16d @ 16” O.C.

CONTINUOUS SEALANT AT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

USE NAILS PER TREATED MANUFACTURERS SILL PLATE RECOMMENDATIONS FOR SIZE AND SPACING CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE-TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES CONCRETE OR MASONRY FOUNDATION WALL

ANCHOR BOLT AS REQUIRED BY CODE

FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL C

Fig. 5 FINISH ROOFING MATERIAL ROOFING FELT

8d COMMON FOAM RIDGE CAP NAILS @ 6" O.C. BOTH SIDES SIP ROOF PANEL CONTINUOUS SEALANT EACH SIDE OF FRAMING AND BOTH FACES AS RECOMMENDED BY MANUFACTURER

SEALANT AS RECOMMENDED BY MANUFACTURER

SIPS SCREWS WITH 1" MIN. PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM

SIP TAPE AT RIDGE REQUIRED DRYWALL

STRUCTURAL SUPPORT MEMBER WITH CONTINUOUS FIELD MIN. 1-1/2" BEARING FOR EACH SIDE OF INSTALLED WOOD PANELS RIDGE SUPPORT BEAM SHOWN

ROOF-TO-ROOF PANEL CONNECTIONS FOAM RIDGE CAP DETAIL

Fig. 6 MINIMUM 3/8" GAP FOR SEALANT AS FINISHED RECOMMENDED BY ROOFING MATERIAL MANUFACTURER

ROOFING BLOCKING AS REQUIRED FELT BY STRUCTURAL CONDITIONS

SIPS SCREWS W/ MINIMUM 1" PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM

SIP TAPE AT RIDGE REQUIRED

RIDGE SUPPORT BEAM

ROOF-TO-ROOF PANEL CONNECTIONS BEVELED SIP RIDGE DETAIL

Fig. 7 PANEL

FINISHED ROOFING MATERIAL

ROOFING FELT

SIP ROOF PANEL 8d COMMON NAILS @ 6" O.C. EACH SIDE CONTINUOUS SEALANT EACH SIDE OF FRAMING AS RECOMMENDED BY MANUFACTURER, AND ROOF PANEL 2x JOINT

TOP PLATE DRYWALL

SIP WALL PANEL DRAINED AND VENTILATED CLADDING

ROOF-TO-WALL PANEL CONNECTIONS BEVELED SIP WALL

Fig. 8 WEDGE INFILL PIECE

PANEL SCREW

FINISHED ROOFING MATERIAL

ROOFING FELT

CONTINUOUS SEALANT EACH SIDE SIP ROOF OF FRAMING AS RECOMMENDED BY PANEL MANUFACTURER

CONTINUOUS SEALANT EACH SIDE OF FRAMING, 8d COMMON NAILS AND ROOF PANEL @ 6" O.C. BOTH SIDES 2x JOINT

TOP PLATE DRYWALL CONTINUOUS SEALANT EACH SIDE SIP WALL PANEL OF FRAMING AS RECOMMENDED BY MANUFACTURER DRAINED AND VENTILATED CLADDING

ROOF-TO-WALL PANEL CONNECTIONS WEDGE INFILL PIECE

Fig. 10 8d COMMON NAILS 6" O.C. BOTH SIDES CONTINUOUS SEALANT BOTH SIDES TYP. OF FRAMING AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT TYPICAL AS RECOMMENDED BY MANUFACTURER 16d COMMON NAILS @ 16" O.C. FINISHED ROOFING MATERIAL

ROOFING FELT

SIP TAPE AT RIDGE REQUIRED

ROOF-TO-ROOF PANEL CONNECTIONS RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG)

Fig. 11 SECOND FLOOR DRYWALL SIP WALL PANEL STANDARD WIRE CHASE 16d COMMON NAILS @ 16" O.C. WHEN USED AS BRACING (3) 16d COMMON NAILS @ 16" O.C.

DRAINED AND CONTINUOUS SEALANT EACH SIDE OF VENTILATED FRAMING TYP. AS RECOMMENDED BY CLADDING MANUFACTURER

2x BOTTOM PLATE 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND 8d COMMON OVER TOP OF SIP WALL NAILS @ 6" O.C. BOTH SIDES FLOOR

METAL STRAP AS REQUIRED OR LTP4 SIMPSON CLIP

CAP PLATE

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER TOP FLANGE METAL FLOOR JOIST HANGAR (BY OTHERS)

FIRST FLOOR DRYWALL

2ND FLOOR CONNECTION DETAILS HANGING FLOOR

Fig. 12 SECOND FLOOR DRYWALL SIP WALL PANEL STANDARD WIRE CHASE

16d COMMON NAILS @ 16" O.C. DRAINED AND WHEN USED AS BRACING (3) 16d VENTILATED COMMON NAILS @ 16" O.C. CLADDING

2x BOTTOM INSULATION PLATE 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND 8d COMMON OVER TOP OF SIP WALL NAILS @ 6" O.C. BOTH SIDES FLOOR JOISTS (I-JOIST SHOWN)

METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD

RIM BOARD

METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD FIRST FLOOR

CONTINUOUS SEALANT EACH SIDE OF 8d COMMON FRAMING TYP. AS RECOMMENDED BY NAILS @ 6" O.C. MANUFACTURER BOTH SIDES

CAP PLATE AS REQUIRED BY MANUFACTURER

DRYWALL

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

2ND FLOOR CONNECTION DETAILS RIM BOARD

Fig. 13 ROOFING FELT

SIP ROOF PANEL

FINISHED ROOFING MATERIAL

AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA.

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER

ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE DRIP EDGE FLASHING

FASCIA

SOFFIT BOARD

EAVES DETAILING EAVES DETAIL A

Fig. 14 ROOFING FELT

SIP ROOF PANEL

FINISHED ROOFING MATERIAL

AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

DRIP EDGE CONTINUOUS SEALANT AS FLASHING RECOMMENDED BY MANUFACTURER

ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE 2X BLOCKING TO SUPPORT 8d COMMON NAILS FASCIA BOARD @ 6" O.C. BOTH SIDES

2x FRAMING MEMBER FASCIA

SIP SCREW SOFFIT BOARD

EAVES DETAILING EAVES DETAIL B

Fig. 15 ROOFING FELT

SIP ROOF PANEL

FINISHED ROOFING MATERIAL

AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA.

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. RECOMMENDED BY

DRIP EDGE USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING.

2x FRAMING MEMBER

CONTINUOUS SEALANT RECOMMENDED BY 2x FRAMING MEMBER MANUFACTURER

8d COMMON NAILS @ 6" O.C. BOTH SIDES FASCIA SOFFIT BOARD SIP SCREW

EAVES DETAILING EAVES DETAIL C

Fig. 16 ROOFING FELT

SIP ROOF PANEL

FINISHED ROOFING MATERIAL

AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

DRIP EDGE FLASHING 8d COMMON NAILS @ 6" O.C. BOTH SIDES

CONTINUOUS SEALANT BEVELED AS RECOMMENDED BY BLOCKING MANUFACTURER TO SUPPORT FASCIA BOARD ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE

FASCIA

SOFFIT BOARD USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING.

EAVES DETAILING EAVES DETAIL D Fig. 17 ROOFING FELT

SIP ROOF PANEL

FINISHED ROOFING MATERIAL

AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA

CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY

DRIP EDGE

8d COMMON NAILS @ 6" O.C. BOTH SIDES CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER

ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE

USE NAILS PER MANUFACTURER'S RECOMMENDATIONS FOR SIZE AND SPACING. FASCIA SOFFIT BOARD

EAVES DETAILING EAVES DETAIL E

Fig. 18 CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER

SIP PANEL EXPANSION GAP 1/8"

8d COMMON NAILS SEALANT AS RECOMMENDED @ 6" O.C. EACH STRIP BY MANUFACTURER AND EACH SIDE

CHASE FOR EXPANDED FOAM SEALANT

WALL-TO-WALL VERTICAL PANEL CONNECTIONS SURFACE SPLINE FOR VERTICAL SPLICE

Fig. 19 2x FRAMING AROUND WINDOWS AND OPENINGS

DOOR AND WINDOW FRAMING

Fig. 21 (2) ROWS 16d COMMON NAILS@ 16" O.C. MINIMUM

SIP PANEL EXPANSION GAP 1/8"

8d COMMON NAILS CONTINUOUS SEALANT EACH @ 6" O.C. EACH PANEL SIDE OF FRAMING TYP. AS AND EACH SIDE RECOMMENDED BY MANUFACTURER

WALL-TO-WALL VERTICAL PANEL CONNECTIONS DIMENSIONAL SPLINE

Fig. 20 CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED DOUBLE 2x SPLINE BY MANUFACTURER VALLEY CUT FLASHING

SIP ROOF PANEL

16d COMMON NAILS @ 16" SIPS SCREW SIP TAPE O.C. MINIMUM W/ MINIMUM 1" 8d COMMON NAILS @ PENETRATION 6" O.C. EACH PANEL INTO STRUCTURAL AND EACH SIDE SUPPORT

CONTINUOUS SEALANT STRUCTURAL SUPPORT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY DRYWALL MANUFACTURER AT SUPPORT MEMBERS

ROOF-TO-ROOF PANEL CONNECTIONS VALLEY DETAIL

Fig. 22 SIP PANEL EXPANSION GAP 1/8"

8d COMMON NAILS CONTINUOUS SEALANT @ 6" O.C. EACH PANEL EACH SIDE OF FRAMING TYP. AND EACH SIDE AS RECOMMENDED BY MANUFACTURER

BLOCK SPLINE

WALL-TO-WALL VERTICAL PANEL CONNECTIONS BLOCK SPLINE

Fig. 23