Line Manhole (Sewer and Storm Drain)
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
LHC 02570-1 SECTION 02570 MANHOLE CONSTRUCTION PART 1 – GENERAL 1.1 Description A. Description of the Work the Work to Be Perf
SECTION 02570 MANHOLE CONSTRUCTION PART 1 – GENERAL 1.1 Description A. Description of the Work The work to be performed in accordance with this section includes precast or cast in place concrete manhole construction for sewer and storm drain collection systems. The work shall include the furnishing of all labor, tools, equipment, materials and performing all required operations to provide a complete item in accordance with the project plans and these specifications. B. Related Work Specified Elsewhere Trench Excavation and Backfill..........................Section 02300 Sewer Line Construction...................................Section 02560 Storm Drain Construction..................................Section 02500 1.2 Quality Assurance A. Reference Test Standards and Specifications ASTM A48, Specifications for Grey Iron Castings ASTM C478, Specification for Precast Reinforced Concrete Manhole Sections ASTM C1107, Specification for Packaged Dry, Hydraulic-Cement Grout, Nonshrink ASTM D4101, Specification for Propylene Plastic Injection and Extrusion Materials AWWA C210, Standard for Liquid Epoxy Coating Systems for the Interior and Exterior of Steel Water Pipelines LHC 02570-1 B. Leakage Test Test all manholes installed under this contract using the vacuum method described below. Provide all equipment necessary to perform the test. Coordinate test schedule with the OWNER. Test will not be accepted unless witnessed by the OWNER. 1. Test each manhole immediately after assembly and prior to backfilling. 2. Plug all lift holes with an approved non-shrink grout. 3. Plug all pipes entering the manhole, taking care to securely brace the plug from being drawn into the manhole. 4. Place the test head inside of the top of the cone section and inflate seal in accordance with the manufacturers recommendations. -
Storm Drain Marking
Storm Drain Marking Part of the City of Ashland Curb to Creek Campaign A STEP -BY-STEP GUIDE FOR NEIGHBORHOOD VOLUNTEER LEADERS Ashland Parks & Recreation North Mountain Park Nature Center 620 North Mountain Avenue Ashland, OR 97520 Phone: (541) 488-6606 Fax: (541) 488-6607 Email: [email protected] 1 Table of Contents What is Storm Drain Marking …………………………………………….……. Page 3 The First Steps for Neighborhood Leaders ……………………................. Page 3 Neighborhood Registration Form .......................………………............. Page 4 Getting Ready to Mark …...................…………………………….……....... Page 5 List of Materials in Marking Kits ……………………………….…………….Page 6 How to Mark the Storm Drain ..…......…....………………………………Pages 6-9 Safety First Locate and Prepare Stomp the Pad Record Activity Telling Neighbors about Curb to Creek …………………………….…….. Page 10 The Final Steps ..………...........................................………………….…Page 11 Project Report Form …………………………….………………………......... Page 12 Adult Volunteer Consent Form……………….………………………......... Page 13 Youth Volunteer Consent Form..…………….………………………......... Page 14 2 WHAT IS STORM DRAIN MARKING ? Storm drain marking is an educational program designed to inform citizens about the hazards of dumping pollutants into storm drains. The placards remind people that storm drains flow untreated, directly into local streams and creeks. Ashland’s storm drains are NOT connected to the sewage treatment plant. By placing storm drain markers, you can take an active roll in preventing pollution in your neighborhood. Volunteers may also distribute door hangers, informing citizens about the proper disposal of chemicals that could harm wildlife and pollute waterways. Storm drain marking helps build community and mobilize grass roots environmental protection. Marking also helps educate your neighbors about the importance of watershed protection. If you are interested, you can become a neighborhood leader for your own Storm Drain Stomp event. -
Section 02560 Manholes Part 1
SECTION 02560 MANHOLES PART 1 - GENERAL 1.01 SCOPE The work covered by this Section includes furnishing all labor, equipment and materials required to install cast-in-place, and/or precast concrete manholes, and concrete junction chambers as described herein and/or shown on the Drawings. 1.02 DESIGN CRITERIA A. Manholes shall be constructed of specified materials to the sizes, shapes, and dimensions and at the locations shown on the Drawings or as otherwise directed by the ENGINEER. The height or depth of the manhole will vary with the location, but unless shown otherwise on the Drawings shall be such that the top of the manhole frame will be at the finished grade of the pavement or ground surface and the invert will be at the designed elevations. B. Where the difference in the invert elevation of a sewer 18 inches in diameter or smaller and any other sewer intersecting in one manhole is 18 inches or more, a dropmanhole shall be constructed as shown on the Drawings. They shall be similar in construction to the standard manhole except that a drop connection of pipe and fittings of the proper size and material shall be constructed outside the manhole and be supported by Class B Concrete. 1.03 QUALITY ASSURANCE A. Prior to delivery all basic materials specified herein shall be tested and inspected by an approved independent commercial testing laboratory or, if approved by the ENGINEER, certified copies of test reports prepared by the manufacturer's testing laboratory will be acceptable. All materials which fail to conform to these specifications shall be rejected. -
Allen County Storm Drain Marking Guide022510
The Allen County Surveyor’s Office has established a storm drain marking program to involve and educate the community of the harms of dumping pollutants down the storm drains. The following guidelines are provided to assist individuals, groups or organizations in planning, implementing, and preparing a successful storm drain marking event and to provide information on what citizens can do to prevent or reduce pollution that enters our waterways through storm drains. What is a Storm Drain? A storm drain is a network of underground pipes designed to control flooding by transporting stormwater from urban areas to a waterbody. The storm drain marking program involves marking storm drain inlets. The following are typical examples of storm inlets. What is Storm Drain Marking? Storm drain marking is labeling a storm drain inlet with a pre-printed marker, tile, sticker, or stencil that reads “ Dump No Waste - Drains to River ”, "Drains to Stream ”, or a similar written message that specifies the waterbody to which the storm drain inlet drains. Allen County has chosen a vinyl marker that comes in circular or rectangular form that is applied to the inlet with an adhesive or tie straps depending on the type of inlet being marked. Why Should We Mark Storm Drains? • Storm drain marking informs others about the street-to-river connection. Allen County 1 Storm Drain Marking Guide Surveyor’s Office • Many people may not realize that water flowing into storm drains or any material that is dumped or washes into the storm drains is not treated before it empties into a river, stream, or pond. -
Infiltration Trench & Soakaway
An Infiltration Trench System includes an inlet pipe or water source, catch basin sump, perforated DESIGN PRINCIPLES distribution pipe, infiltration trench and overflow to the storm drainage system. ■ Infiltration Trench System: A Soakaway Manhole (Sump, or Dry Well) System includes an inlet pipe, a sedimentation manhole, and one or more infiltration shafts with connecting pipes. Use of Infiltration Shaft will be limited by hydro- a) Locate infiltration trench at least 3m geotechnical conditions in much of GVRD. from any building, 1.5m from Limitations of Infiltration Trench or Soakaway Manholes: property lines, and 6m from adjacent a) To avoid groundwater pollution, do not direct un-treated polluted runoff to Infiltration Trench or Shaft: infiltration facilities (or as recommended by a geotechnical ▪ Direct clean runoff (roof, non-automobile paving) to Infiltration Trench or Shaft. engineer). ▪ For polluted runoff (roads > 1000 vehicles / day, parking areas, other pollution sources), provide upstream source control for pollutant reduction prior to release to Infiltration Trench or Shaft. b) Sump: Provide a lid for periodic b) Use infiltration trench or shaft only in areas with footing drains. inspection and cleanout. Include a 1. Grass or Other Planting T-inlet pipe to trap oils, sediments 2. Finish Grade and debris. 3. Growing Medium Backfill 4. 100mm Dia PVC DR28 Perforated 19 c) Infiltration Trench: installation of Pipe distribution pipe and bottom of 5. Light Non-woven Polyester drainrock to be level. If more than Geotextile c/w Min. 400mm Laps one section of infiltration trench is 9 1 required, design so that underground 6. 50mm Drain Rock or Rock of water is temporarily ‘ponded’ in each Equal Porosity infiltration section. -
SDD 8B10 Manholes 3X3-FT, 4X4-FT, 5X5-FT, and 6X6-FT
SDD 8b10 Manholes 3x3-FT, 4x4-FT, 5x5-FT, and 6x6-FT PRECAST OR CAST-IN-PLACE GENERAL NOTES REINFORCED CONCRETE FLAT SLAB TOP DETAILS OF CONSTRUCTION, MATERIALS AND WORKMANSHIP NOT SHOWN ON THIS DRAWING SHALL CONFORM TO THE PERTINENT REQUIREMENTS OF THE STANDARD SPECIFICATIONS AND THE APPLICABLE SPECIAL PROVISIONS. UNLESS OTHERWISE AUTHORIZED IN WRITING BY THE ENGINEER, THE CONTRACTOR SHALL NOT ORDER AND DELIVER PRECAST MANHOLE UNITS REQUIRED FOR THE PROJECT UNTIL A LIST OF SIZES IS FURNISHED BY THE ENGINEER. 2" (TYP) B B DETAILED DRAWINGS FOR PROPOSED ALTERNATE DESIGNS FOR UNDERGROUND DRAINAGE STRUCTURES SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PROVIDING THAT SUCH ALTERNATE DESIGNS MAKE PROVISION FOR EQUIVALENT CAPACITY AND STRENGTH. SEE MATRIX ALL DRAINAGE STRUCTURES ARE DESIGNATED ON THE PLANS AS "MANHOLES 3X3-L", "CATCH BASINS 4-B", TOP WITH PLAIN END JOINT "INLETS 2X3-H", ETC. THE FIRST NUMBERS DESIGNATE THE SIZE OF THE STRUCTURE, AND THE FOLLOWING LETTER DESIGNATES THE TYPE OF COVER TO BE USED TO COMPRISE THE COMPLETE UNIT. BASES SHALL BE PLACED ON A BED OF MATERIAL AT LEAST 6 INCHES IN DEPTH, WHICH MEETS THE REQUIREMENTS OF FOUNDATION BACKFILL. THIS BEDDING SHALL BE COMPACTED AND PROVIDE UNIFORM " 8 SUPPORT FOR THE ENTIRE AREA OF THE BASE. 4" OVERHANGING BASE PRECAST REINFORCED FLAT SLAB TOPS MAY BE USED ON CONCRETE BLOCK STRUCTURES. 1 OR 2 2 STEPS MEETING AASHTO M199 AND THE FOLLOWING REQUIREMENTS SHALL BE INSTALLED IN ALL STRUCTURES OVER 5 FEET IN DEPTH: 16 INCH C-C MAXIMUM SPACING; PROJECT A MINIMUM CLEAR DISTANCE OF 4 INCHES FROM PLAN VIEW THE WALL AT THE POINT OF EMBEDMENT; MINIMUM LENGTH OF 10 INCHES; MINIMUM WALL EMBEDMENT OF 3 CIRCULAR OPENING SECTION A-A INCHES. -
D400tc – Composite Manhole Cover Class D400 – En 124:1994
Rev. 00 D400TC – COMPOSITE MANHOLE COVER CLASS D400 – EN 124:1994 DESCRIPTION PROPERTIES Manhole covers and gully tops Marked with resistance class, for use in vehicular and reference norm, producer pedestrian areas. Design identification and quality requirements, type testing, mark released by an marking, quality control internationally according to the UNI EN acknowledged certification 124:1994 standard. authority. Certificate issued by ICMQ. Made up of: - round frame - round cover - locking system with 180° or 120° hinge Name of the client or of the optional service. Embossed pattern available on request. PRODUCTION PROCESS Illustrations and drawings APPLICATION AREAS AND MATERIAL are purely illustrative Test load kN 400. The manhole cover is Carriageways (including manufactured through the pedestrian streets), SMC process, i.e. compression hardshoulders and parking moulding in a closed mould, areas for all types of road using a Sheet Moulding vehicles. Compound (polyester reinforced with glass fibres). Raw materials: orthophtalic polyester resin, chopped strand in glass fibres (type E), additives. Hinges and closing systems are made of galvanized steel. Weight of the D F H h cover + weight MODEL C/O Fixing Seal (mm) (mm) (mm) (mm) of the frame (Kg) 180° hinge and D400TC/600_001 600 690 805 100 50 Yes 36 + 17 lock 120° hinge and D400TC/600_002 600 650 790 100 48 Yes 31,6 + 13,4 lock 180° hinge and D400TC/700_001 700 750 910 100 50 Yes 45,5 + 20,5 lock Rev. 00 D400T - COMPOSITE MANHOLE COVER CLASS D400 – EN 124:1994 DESCRIPTION PROPERTIES Manhole covers and gully tops Marked with resistance class, for use in vehicular and reference norm, producer pedestrian areas. -
Version 09-10-2019
Version 09-10-2019 Version 09-10-19 Table of Contents SECTION 1- GENERAL REQUIREMENT ............................................................................................ 1 1.01 Short Title .................................................................................................................................... 2 1.02 Interpretation ............................................................................................................................... 2 1.03 Enforcement ................................................................................................................................ 2 1.04 Amendment ................................................................................................................................. 2 1.05 Deviation Requests ...................................................................................................................... 2 1.06 Applicability ................................................................................................................................ 3 1.07 Other Local, State and Federal Environmental Regulations .......................................................... 3 1.08 Texas Accessibility Standards (TAS) ........................................................................................... 3 1.09 Engineering Criteria – Section Descriptions ................................................................................. 4 1.10 Submittal Requirements for Construction Plans ........................................................................... -
Drainage Design Manual
THE CITY OF SAN DIEGO Transportation & Storm Water Design Manuals Drainage Design Manual January 2017 Edition The City of San Diego | Drainage Design Manual | January 2017 Edition DRAINAGE DESIGN MANUAL THIS PAGE INTENTIONALLY LEFT BLANK FOR DOUBLE-SIDED PRINTING The City of San Diego | Drainage Design Manual | January 2017 Edition CONTENT Contents Contents ............................................................................................................................................................... i Figures ............................................................................................................................................................... vii Tables .................................................................................................................................................................. ix Equations ............................................................................................................................................................. x 1. Introduction.............................................................................................................................................. 1-1 Policies ............................................................................................................................................... 1-1 Basic Objectives ......................................................................................................................... 1-2 Exceptions to Design Standards ............................................................................................. -
City Wide Drainage Assessment Report
City of Summit City Wide Drainage Assessment Report Dept. of Community Services Division of Engineering Revised - July 2020 Aaron Schrager, City Engineer Rick Matias, Assistant City Engineer Lori Toth, Assistant Engineer Page 1 of 37 Table of Contents INTRODUCTION 3 SUMMARY 5 CATEGORY I – DRAINAGE LOCATIONS 1. Golf Course Pond (Permitting Phase) 7 2. Salt Brook 8 3. West End Avenue Erosion 9 4. Railroad Culverts 10 5. Middle Avenue Culvert 11 6. Beekman Road Culvert 12 CATEGORY II – DRAINAGE LOCATIONS 7. Briant Parkway, Easements near Springfield Avenue intersection 14 8. Portland Road – At Dorchester Road 15 9. Tulip Street – Oakland Place to Linden Place 16 10. Kenneth Court and Crest Acre Court 17 11. Morris Avenue at Elm Street Condo Driveway 18 12. Martins Brook 19 CATEGORY III – DRAINAGE LOCATIONS 13. Huntley Road (Under Construction) 21 14. Gloucester Road (Design Complete – Awaiting Construction) 22 15. Wade Drive 23 16. Sweet Briar Road / Plymouth Road (Under Construction - Phased) 24 17. Dorset Lane Icing 25 18. Club Drive 26 19. Ox Bow Lane 27 20. Princeton Street 28 21. Division Avenue Bridge (Part of #2) 29 22. Beverly Road & Sheridan Road 30 Page 2 of 37 COMPLETED PROJECTS (Pages 31-37) 1. 236 Springfield Avenue “The Dell” (Designed Completed-work not to be completed) 2. Whittredge Road/Dogwood Drive (Completed Fall 2007) 3. New Providence Avenue (Completed 2007) 4. Sheffield Road (Completed Fall 2008) 5. Memorial Field Basketball Courts (Completed 2008) 6. 8 & 12 Sweet Briar Road (Completed – Fall 2009) 7. Springfield Avenue and Summit Avenue (Completed – Fall 2009) 8. Laurel Avenue (Completed – Fall 2009) 9. -
How Do Storm Drains Work?
How do Storm Drains Work? The storm drainage system helps prevent floods by diverting rainwater into nearby waterways. During rainstorms, water runs off of buildings, roads, and other hard surfaces, picking up trash and pollutants along the way. The water and pollutants flow into storm drains and through underground pipes directly into the nearest stream, pond or water reservoir. What About the Drains in My House? The drains in your house are part of a different system, the wastewater system. Dirty water from inside your home flows into underground pipes that are connected to a wastewater treatment plant. The water from your home is cleaned before it is released back into creeks and streams. Stormwater is Not Treated? That’s right! The storm drainage system carries rainwater directly to creeks, streams, ponds and reservoirs. That is why it’s important to keep trash, motor oil, pesticides, and other chemicals from entering the storm drain – everything that goes in comes out in our waterways. Polluted water is harmful to fish, wildlife, and humans. Stormwater Provides Drinking Water to Us and Others Downstream Never pour or dump anything down a storm drain Keep streets clean Dispose of trash properly Rake leaves and debris away from storm drains Apply lawn and garden chemicals sparingly and according to directions Call Wilmington’s Wastewater Treatment Plant (below) to report pollution problems All Water is Recycled The same water that existed on earth in the beginning is still here. It continually moves around, through and above our planet as water vapor, liquid, and ice. The water that comes from our faucets may have been drinking water for the first man and woman. -
Safety of the Intended Functionality of Lane-Centering and Lane-Changing Maneuvers of a Generic Level 3 Highway Chauffeur System (Report No
DOT HS 812 879 November 2020 Safety of the Intended Functionality of Lane- Centering and Lane- Changing Maneuvers of a Generic Level 3 Highway Chauffeur System DISCLAIMER This publication is distributed by the U.S. Department of Transportation, National Highway Traffic Safety Administration, in the interest of information exchange. The opinions, findings, and conclusions expressed in this publication are those of the authors and not necessarily those of the Department of Transportation or the National Highway Traffic Safety Administration. The United States Government assumes no liability for its contents or use thereof. If trade or manufacturers’ names or products are mentioned, it is because they are considered essential to the object of the publications and should not be construed as an endorsement. The United States Government does not endorse products or manufacturers. Suggested APA Format Citation: Becker, C. J., Brewer, J. C., & Yount, L. J. (2020, November). Safety of the intended functionality of lane-centering and lane-changing maneuvers of a generic level 3 highway chauffeur system (Report No. DOT HS 812 879). National Highway Traffic Safety Administration. Technical Report Documentation Page 1. Report No. 2. Government Accession No. 3. Recipient’s Catalog No. DOT HS 812 879 4. Title and Subtitle 5. Report Date Safety of the Intended Functionality of Lane-Centering and Lane-Changing November 2020 Maneuvers of a Generic Level 3 Highway Chauffeur System 6. Performing Organization Code 7. Authors 8. Performing Organization Report No. Christopher Becker, John Brewer, and Larry Yount DOT-VNTSC-NHTSA-19-02 9. Performing Organization Name and Address 10. Work Unit No.