Assuredsan Storage Management Guide (G222)

Total Page:16

File Type:pdf, Size:1020Kb

Assuredsan Storage Management Guide (G222) AssuredSAN Storage Management Guide For firmware release G222 Abstract This guide is for use by storage administrators to manage a Dot Hill AssuredSAN storage system by using its web interface, WBI. P/N 83-00006360-12-01 Revision A January 2016 Copyright © 2016 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill logo, AssuredSAN, AssuredSnap, AssuredCopy, and AssuredRemote are trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, changes in the product design can be made without reservation and without notification to its users. Open Source Third Party Licenses and Code Dot Hill storage products use open source software components. To view information about open source software licenses and open source code used in Dot Hill storage products, see https://www.dothill.com/support. Contents About this guide. 17 Intended audience . 17 Prerequisites . 17 Related documentation . 17 Document conventions and symbols . 18 Part 1: Using WBI v3. 19 1 Getting started . .20 Configuring and provisioning a new storage system . 20 Using the interface. 20 Web browser requirements and setup . 20 Areas of the SMC v3 interface . 21 Tips for using the SMC . 21 Tips for using tables . 22 Tips for using help . 23 Color codes. 23 Size representations . 25 Signing in and signing out. 25 System concepts. 26 About virtual and linear storage . 26 About disk groups . 26 About RAID levels . 28 About SSDs . 30 About SSD read cache . 31 About pools . 31 About volumes and volume groups . 32 About volume cache options . 33 About thin provisioning . 34 About automated tiered storage. 35 About initiators, hosts, and host groups. 35 About volume mapping . 36 About snapshots. 37 About copying volumes . 39 About reconstruction and copyback . 39 About quick rebuild . 40 About performance statistics. 40 About firmware update . 41 About managed logs. 41 About replicating virtual volumes. 42 About the Full Disk Encryption feature (for AssuredSAN 4004 only) . 42 About data protection with a single controller. 43 About SAS cabling (for AssuredSAN 3004 only). 43 Contents 3 2 Working in the Home topic . 44 Viewing overall system status . 44 Host information. 44 Port information . 44 Capacity information. ..
Recommended publications
  • Assuredsan 3004 Series FRU Installation and Replacement Guide for Firmware Release GL200 Or Later
    AssuredSAN 3004 Series FRU Installation and Replacement Guide For firmware release GL200 or later Abstract This document describes removal and installation of field-replaceable units for Dot Hill AssuredSAN 3004 Series controller enclosures, and is intended for use by storage system administrators familiar with servers and computer networks, network administration, storage system installation and configuration, storage area network management, and relevant protocols. P/N 83-00006724-13-01 Revision A October 2014 Copyright © 2014 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill logo, AssuredSAN, AssuredSnap, AssuredCopy, AssuredRemote, R/Evolution, and the R/Evolution logo are trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, changes in the product design can be made without reservation and without notification to its users. Contents About this guide. 7 Overview. 7 AssuredSAN 3004 Series enclosure user interfaces . 7 Intended audience . 7 Prerequisites. 7 Related documentation . 8 Document conventions and symbols . 8 1 FRUs . 10 Available FRUs. 10 Storage enclosure overview . 10 FRUs addressing 24-drive enclosures . 11 Enclosure bezel for 24-drive model . 14 FRUs addressing 12-drive enclosures . 15 Enclosure bezel for 12-drive model . 18 2 Procedures . 19 Electrostatic discharge. 19 Preventing electrostatic discharge . 19 Grounding methods to prevent electrostatic discharge . 19 Replacing chassis FRU components . 20 Replacing a controller module or expansion module .
    [Show full text]
  • Dot Hill Systems Corp
    DOT HILL SYSTEMS CORP FORM 10-K (Annual Report) Filed 03/10/09 for the Period Ending 12/31/08 Address 2200 FARADAY AVENUE SUITE 100 CARLSBAD, CA 92008 Telephone 760-931-5500 CIK 0001042783 Symbol HILL SIC Code 3572 - Computer Storage Devices Industry Computer Storage Devices Sector Technology Fiscal Year 12/31 http://www.edgar-online.com © Copyright 2009, EDGAR Online, Inc. All Rights Reserved. Distribution and use of this document restricted under EDGAR Online, Inc. Terms of Use. Table of Contents UNITED STATES SECURITIES AND EXCHANGE COMMISSION Washington, D.C. 20549 Form 10-K ANNUAL REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934 For the Fiscal Year Ended December 31, 2008 or TRANSITION REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934 For the Transition Period From to Commission file number 1-13317 DOT HILL SYSTEMS CORP. (Exact name of registrant as specified in its charter) Delaware 13 -3460176 (State of Incorporation) (I.R.S. Employer Identification No.) 2200 Faraday Ave, Suite 100 Carlsbad, CA 92008 (Address of principal executive offices) (Zip Code) Registrant’s telephone number, including area code: (760) 931-5500 Securities registered pursuant to Section 12(b) of the Act: Title of Each Class Name of Each Exchange on Which Registered Common stock, $0.001 par value The Nasdaq Stock Market Securities registered pursuant to Section 12(g) of the Act: None Indicate by check mark if the registrant is a well-known seasoned issuer, as defined in Rule 405 of the Securities Act.
    [Show full text]
  • Deploying Innovative Messaging Services Using Optimized System Architecture
    DEPLOYING INNOVATIVE MESSAGING SERVICES USING OPTIMIZED SYSTEM ARCHITECTURE An Infinite Convergence and Dot Hill White Paper April 2014 Message Storage Application (MSA) Solution Brief: Infinite Convergence deploys innovative Telecommunications Messaging Products leveraging flexible Storage Solutions designed for scalability. Deploying cost-effective, innovative messaging products that scale to customer needs while maintaining five 9s availability demanded that Infinite Convergence find a storage solution that was optimized for scalability, flexibility and price. Partnering with Dot Hill and using Cassandra provided Infinite Convergence with a solution that meets the high expectations of the Telecommunication marketplace. Overview Operators are faced with declining messaging revenue as subscribers turn to Over-The-Top (OTT) services as their choice for exchanging mobile messages. According to Ovum, OTT messaging apps will have cost operators $32.6 billion in lost SMS revenue in 2013, rising to $86 billion in 2020. The Message Storage Application (MSA) from Infinite Convergence Solutions provides operators with new innovative messaging services that recapture the attention of the subscriber base. The MSA allows subscribers to start messaging on one device, like a mobile phone, and continue the conversation on another device, like a laptop computer or tablet, using one mobile number. There’s no need to remember multiple numbers for the same user, regardless of which device they may be using. All messages are seamlessly synchronized in real-time across all devices, allowing the subscriber to use his preferred devices for exchanging messages. Message content is stored in the network for easy access. The MSA supports feature-rich capabilities beyond text and picture messaging, including group messaging, location sharing and searching.
    [Show full text]
  • Sanpath User's Guide
    SANpath User’s Guide Version 4.0 June 2004 83-00002722, Revision B Copyright Copyright 2001-2004 Dot Hill Systems Corp. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form or by any means – manual, electric, electronic, electromechanical, chemical, optical, or otherwise – without prior explicit written permission of Dot Hill Systems Corp., 6305 El Camino Real, P.O. Box 9000, Carlsbad, CA., 92009-1606. Trademarks Dot Hill Systems, the Dot Hill logo, SANscape, SANnet, and SANpath are registered trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Dot Hill Systems Corp., assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. Dot Hill Systems Corp., reserves the right to make changes in the product design without reservation and without notification to its users. Contents Preface . .vii 1. Overview . .1 What is SANpath? . .1 Failover/Failback Data Paths . .1 I/O Load Balancing . .2 Dynamic LUN Masking . .2 How SANpath Works . .2 Supported SANpath Configurations . .2 Summary of SANpath Benefits . .3 2. Hardware Preparation . .5 Hardware Overview . .5 Multiple I/O Paths . .5 Host Computer and Storage Devices . .5 Example Configurations . .6 Host LUN Mapping . .7 3. SANpath Operation . .9 Overview . .9 The setsp Command .
    [Show full text]
  • Assuredsan 6004 CLI Reference Guide for Firmware Release GF101 Or Later
    AssuredSAN 6004 CLI Reference Guide For firmware release GF101 or later Abstract This guide provides information about managing a Dot Hill AssuredSAN 6004 storage system by using its command-line interface (CLI). P/N 83-00006818-11-01 Revision A May 2015 Copyright © 2015 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill logo, AssuredSAN, EcoStor, and SimulCache are trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, changes in the product design can be made without reservation and without notification to its users. Contents About this guide. 10 Intended audience . 10 Prerequisites. 10 Document conventions and symbols . 10 1 Using the CLI . 12 Accessing the CLI . 12 CLI output formats . 12 Using CLI interactively . 13 Using a script to access the CLI . 13 Using the XML API . 16 Scripting guidelines . 17 XML API examples . 17 XML API optimization . 18 Command syntax . 18 General rules for specifying commands . 18 Specifying drawers . 19 Specifying disks. 19 Specifying vdisks . 19 Specifying disk groups . 19 Specifying volumes . 19 Specifying ports. 20 Specifying initiators and hosts . 20 Specifying fan modules . 20 User password rules. 20 Command completion, editing, and history . 21 Viewing help . 21 Size representations . 21 Event log . 22 2 Categorical list of commands. 23 3 Alphabetical list of commands . 24 abort scrub . 25 abort verify .
    [Show full text]
  • Assuredsan 4000 10.2.12.Indd
    AssuredSAN™ 4000 Series SMART, SIMPLE STORAGE Dot Hill’s AssuredSAN™ Solutions offer a smart, simple approach to storage management. The AssuredSAN™ Solutions combine high per- Scalable Performance formance and high capacity storage with the ease of the RAIDar man- 5200 MB/s throughput and 100,000 IOPS from agement GUI which provides a complete set of features and tools to disk ensure easy storage administration. SimulCache™ - Low latency cache mirroring In common with all AssuredSAN storage arrays, the 4000 Series boasts Data rates up to 8Gb/sec. FC or 6Gb/sec. SAS 99.999% availability due to stringent design standards, testing, and di- Up to 7 expansion units per system agnostics. Support for SAS, Nearline SAS, SSDs Max 192 drives - 4520, 4720, 96 - 4530, 4730 Built in Redundancy M&E Workfl ows Dual RAID controller The AssuredSAN 4000 Series sets a new storage standard for postpro- Redundant, hot swap components duction workfl ows. Offering 5200 megabytes per second sequential RAID 0, 1, 3, 5, 6, 10, 50 reads and 3000 megabytes per second sequential writes, this Series is ideal for video editing, fi nishing, rendering and streaming, as well as Certifi cations and Virtualization broadcast, and telecommunications capture. Citrix, Microsoft, VMware The 4000 Series is a shared storage system that works with shared fi le systems like StorNext and Xsan to easily support multiple simultane- Green Features ous streams of 2K, 4K, HD and 3D content, without dropping frames. EcoStor™ battery-free cache backup Drive-spin-down Similarly, the 4000 system has the high performance and low latency RoHS-6 and WEEE compliant characteristics to meet data capture requirements for modern tele- communications digital networks and broadcast applications.
    [Show full text]
  • Sannet II 200 SCSI Array Installation, Operation, and Service Manual
    SANnet II 200 SCSI Array Installation, Operation, and Service Manual June 2005 83-00002359, Revision C Copyright Copyright 2001-2005 Dot Hill Systems Corp. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form or by any means – manual, electric, electronic, electromechanical, chemical, optical, or otherwise – without prior explicit written permission of Dot Hill Systems Corp., 6305 El Camino Real, P.O. Box 9000, Carlsbad, CA., 92009-1606. Trademarks Dot Hill Systems, the Dot Hill logo, SANscape, SANnet, and SANpath are registered trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Dot Hill Systems Corp., assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. Dot Hill Systems Corp., reserves the right to make changes in the product design without reservation and without notification to its users. Contents Preface . ix 1. Product and Architecture Overview . .1–1 1.1 SANnet II 200 SCSI Arrays . .1–1 1.2 Array Configurations . .1–2 1.3 SCSI Architecture . .1–3 1.3.1 Redundant Configuration Considerations . .1–4 1.4 Device Identification . .1–4 1.5 Field-Replaceable Units (FRUs) . .1–5 1.5.1 RAID I/O Controller Modules . .1–5 1.5.2 I/O Expansion Modules .
    [Show full text]
  • Midrange Array Buyer's Guide
    NGE A RA RR D A I Y M BUYER’S GUIDE 2010 MIDRANGE ARRAY BUYER’S GUIDE The Insider’s Guide to Evaluating FC and iSCSI Midrange Arrays By Jerome M Wendt DCIG, LLC | 7511 Madison Street | Omaha NE 68127 | 402.884.9594 DCIG 2010 MIDRANGE ARRAY BUYER’S GUIDE The Insider’s Guide to Evaluating FC and iSCSI Midrange Arrays Table of Contents 1 Introduction 23 Midrange Array Models 3 Executive Summary 24 3PAR InServ F200 60 HDS AMS2100 25 3PAR InServ F400 61 HDS AMS2300 4 How to Use this 26 Celeros EzSANFiler XD34S 62 HDS AMS2500 Midrange Array Buyer’s Guide 27 Celeros EzSANFiler XF34S 63 HP EVA4400 28 Celeros EzSANFiler XD46S 64 HP EVA6400 5 Disclosures 29 Celeros EzSANFiler XF46S 65 HP EVA8400 5 Midrange Array Inclusion 30 Celeros EzSANFiler XD49S 66 HP MSA2000i and Exclusion Criteria 31 Celeros EzSANFiler XF49S 67 HP P2000 G3 32 Celeros EzSANFiler XD512 68 HP P4300 6 The 8-Step Process Used 33 Celeros EzSANFiler XF512 69 IBM DS5020 Express to Score and Rank Midrange Arrays 34 Celeros EzSANFiler XD810 70 Infortrend ESVA E20 35 Celeros EzSANFiler XF810 71 Infortrend ESVA F20 7 DCIG Comments and Thoughts on … 36 Compellent Storage Center 72 NEC D3 7 Midrange Array Performance and Pricing Series 20 73 NEC D3i 8 Power and Space Efficiency 37 Compellent Storage Center 74 NEC D4 9 Reliability and Functionality Series 30 75 NEC D8 38 Dell EqualLogic PS4000E 76 NetApp FAS2020 9 DCIG Observations and 39 Dell EqualLogic PS4000X 77 NetApp FAS2040 Recommendations Regarding 40 Dell EqualLogic PS4000XV 78 NetApp FAS2050 Each Midrange Arrays Ranking 41 Dell
    [Show full text]
  • Storage Designed for Availability Dot Hill Assuredsan™ & Sansymphony™-V
    PARTNER TECHNICAL BRIEF Storage Designed for Availability Dot Hill AssuredSAN™ & SANsymphony™-V Dot Hill AssuredSAN Designing a data storage infrastructure for high availability requires the selection of 12-bay & 24-bay systems the most reliable hardware components, coupled with intelligent data management software to assist recovery of critical business data regardless of the cause of failure. Solution Highlights This paper outlines the design techniques employed to achieve high availability in the Dot Hill AssuredSAN series of storage arrays with an overview of the methods ● Virtualized storage enables seamless failover (HA) and WAN of replication available within the DataCore SANsymphony-V platform. replication (DR) ● Test function allows for simulated DataCore Ready Certified disaster recovery The combination of SANsymphony-V and Dot Hill AssuredSAN storage arrays ● Eliminates single points of failure which are certified under the rigorous DataCore Ready Program offers a rock solid storage foundation built upon storage hardware designed for availability and a data Dot Hill AssuredSAN management layer providing both asynchronous and synchronous replication. Highlights Keeping Users And Applications Running Undisturbed ● DataCore Ready certified ● Demonstrated 99.999% Highly reliable storage hardware is a vital foundation for business continuity availability but many IT organizations fail to account for the multitude of other factors ● Designed for high availability that greatly contribute to business upheaval. DataCore storage virtualization software prevents these more frequent sources of storage-related disruptions ● NEBS & MIL-STD-810G compliant from ever affecting applications and we enable you to do this in a cost-effective manner that leverages a variety of different devices for redundancy. ● Certified with VMware ESX, vSphere, Microsoft and Citrix Xen Server The Datacore Ready Program Value Proposition DataCore Ready identifies solutions trusted to strengthen SANsymphony-V- based infrastructures.
    [Show full text]
  • Nova Storage Series Setup Guide
    +1 847. 205.1922 [email protected] www.bcdvideo.com NOVA STORAGE SERIES SETUP GUIDE C US Copyright © 2015 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill logo, AssuredSAN, AssuredSnap, AssuredCopy, AssuredRemote, R/Evolution, and the R/Evolution logo are trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, changes in the product design can be made without reservation and without notification to its users. Contents About this guide. 10 Overview. 10 Nova Storage Series enclosure user interfaces. 10 CNC ports used for host connection. 11 HD mini-SAS ports used for host connection . 11 Intended audience . 11 Prerequisites. 11 Related documentation . 12 Document conventions and symbols . 12 1 Components . 14 Front panel components . 14 56-drive enclosure front panel components . 14 Enclosure bezel installed . 14 Enclosure bezel removed . 15 Enclosure drawers . 15 Disk drives used in 4U56 enclosures . 16 Controller enclosure — rear panel layout. 17 4854 controller module — rear panel components . 18 4554 controller module — rear panel components . 19 J6G56 drive enclosure rear panel components. 19 Component installation and replacement . 20 Cache . 20 CompactFlash . 20 Supercapacitor pack. 21 2 Installing the enclosures. 22 Installation checklist . 22 Populating drawers. 23 Opening and closing a drawer . 23 Aligning a disk module for installation into a drawer . 24 Installing a disk module . 25 Removing a disk module.
    [Show full text]
  • Assuredsan 3004 Series Setup Guide for Firmware Release G222
    AssuredSAN 3004 Series Setup Guide For firmware release G222 Abstract This document describes initial hardware setup for Dot Hill AssuredSAN 3004 Series controller enclosures, and is intended for use by storage system administrators familiar with servers and computer networks, network administration, storage system installation and configuration, storage area network management, and relevant protocols. P/N 83-00006725-15-01 Revision A January 2016 Copyright © 2016 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill logo, AssuredSAN, AssuredSnap, AssuredCopy, AssuredRemote, R/Evolution, and the R/Evolution logo are trademarks of Dot Hill Systems Corp. All other trademarks and registered trademarks are proprietary to their respective owners. The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, changes in the product design can be made without reservation and without notification to its users. Contents About this guide. 9 Overview. 9 AssuredSAN 3004 Series enclosure user interfaces . 9 CNC ports used for host connection. 9 HD mini-SAS ports used for host connection . 10 Intended audience . 10 Prerequisites. 10 Related documentation . 10 Document conventions and symbols . 11 1 Components . 13 Front panel components . 13 24-drive enclosure front panel components . 13 12-drive enclosure front panel components . 14 Disk drives used in 3004 Series enclosures . 14 Controller enclosure — rear panel layout. 15 3824/3834 controller module — rear panel components . 16 3524/3534 controller module — rear panel components . 17 J6G24/J6G12 drive enclosure rear panel components .
    [Show full text]
  • Storage Spectacular!
    content provided by STORAGE SPECTACULAR! A comprehensive look at virtual storage from Virtualization Review and Redmond magazine, plus a Storage Buyer’s Guide. > The Storage Infrastruggle Page 1 > Do You Really Need Storage Management Software? Page 17 > Storage: Virtualized vs. Software-DefinedPage 27 > Storage Disruptors Page 36 > In the Cloud Era, the Era of Convergence Is Upon Us Page 49 > The 2014 Virtualization Review Buyers Guide Page 56 SPONSORS Storage Spectacular The Storage Infrastruggle Vendors are battling for the future of your storage spend, but are they sidestepping the key drivers of storage cost? By Jon Toigo hile touting “new,” flash-heavy “server-side” topologies and so-called “software-defined architec- tures” as evolutionary replacements for the “legacy” W SANs and NAS appliances that companies deployed in their previous refresh cycles, the industry continues to ignore the more fundamental drivers of storage inefficiency and cost: lack of management both of infrastructure and of data. 1 Storage Spectacular You would think from news reports that the storage industry was on its last legs. Vendor revenues from sales of everything from hard disk drives to external storage arrays, storage area networks (SANs) and network attached storage (NAS) appliances are either flat or declining ever so slightly. Seagate and Western Digital have hit a patch of dol- drums in which the trends of prior years—the doubling of drive capacities every 18 months and the halving of cost per GB every year—have frozen in their tracks. Even the redoubtable EMC, NetApp and IBM are experiencing purchasing slowdowns at customer shops that shouldn’t be happening if the capacity demand explosion that analysts say accompanies server virtualization is to be believed.
    [Show full text]