Simplevis.Analysis.Of.Errors.In.Viscosity.Measurement.Due.To.Alignment.And.Capillary

Total Page:16

File Type:pdf, Size:1020Kb

Simplevis.Analysis.Of.Errors.In.Viscosity.Measurement.Due.To.Alignment.And.Capillary Analysis of Errors in Viscosity Measurement January 2015 Overview An analysis was conducted to compare the operational characteristics of two different bench‐ top semi‐automated viscometers – the Cannon SImpleVIS and the Spectro Q3000. This analysis looked at three key areas which can lead to errant viscosity measurements when utilizing a capillary viscometer where gravity is the motivating force for the measurement. These errors can range in magnitude from imperceptible (in the noise of the instrument precision) to serious measurement inaccuracies. Diagrams of Viscometer Capillaries VC Head VT Cannon SimpleVIS Viscometer Tube – Fixtured Borosilicate Glass in Aluminum Block Page 1 of 7 Analysis of Errors in Viscosity Measurement January 2015 Spectro Q3000 Viscometer – Removable Aluminum Capillary Cell Operational Faults Studied in this Analysis Angular misalignment of the viscometer off the vertical axis Temperature inaccuracy of the viscometer and sample Contamination or occlusion of the capillary changing the effective diameter Sample charge volume inaccuracies Page 2 of 7 Analysis of Errors in Viscosity Measurement January 2015 All gravity‐flow capillary viscometers are governed by the Hagen‐Poiseuille equation: KV () = H*g*r4*t / (8*L*V) = c * t (mm 2 /s) r = radius of the capillary (mm) L = effective working length of the capillary (mm) H = average driving head of fluid, midway between timing marks (mm) g = gravitational acceleration constant (980.24 cm/s2) V = volume between start and stop timing marks (mL) Angular misalignment of the viscometer off the vertical axis All capillary viscometers are affected, regardless of the length (L) of the capillary and its associated driving head (H), by the angular alignment differences between how it was calibrated and subsequently operated after calibration. The tables below illustrate how severe this angular misalignment can affect the viscosity measurement. Less than 10 degrees tilt can be considered acceptable for bench‐top measurements where precision of less than 2% is accepted. Tilt larger than 10 degrees can lead to serious errors. Driving Driving Head due to Angular Alignment off Vertical Head mm 0° 1° 3° 5° 10° 20° 30° SimpleVIS 88.2 88.20 88.19 88.08 87.86 86.86 82.88 76.38 Q3000 30.0 30.00 30.00 29.96 29.89 29.54 28.19 25.98 Viscosity Percent Viscosity Error due to Angular Alignment off Vertical Range mm2/s 0° 1° 3° 5° 10° 20° 30° SimpleVIS 10‐700 0.00% 0.02% 0.14% 0.38% 1.52% 6.03% 13.40% Q3000* 10‐350 0.00% 0.02% 0.14% 0.38% 1.52% 6.03% 13.40% * note Q3000 angular alignment error is above is only in one axis. Error increases greatly when in the other axis (left/right) due to sample running out of unconfined flow channel Page 3 of 7 Analysis of Errors in Viscosity Measurement January 2015 Viscosity Error due to Alignment 16.0% 14.0% 12.0% Change 10.0% 8.0% Viscosity 6.0% 4.0% Percent 2.0% 0.0% 0° 5° 10° 15° 20° 25° 30° Angular Misalignment off Vertical A key point in the error shown above with the Q3000 viscometer, which utilizes an unbounded (open on two sides) microchannel capillary (Hele‐Shaw flow cell) which is 100 microns by 2 millimeters in dimension, is only valid in one alignment ‐ front to back. The error associated from misalignment towards the unbounded sides of the capillary (left to right) can be quite severe if the surface tension of the fluid (or lack thereof due to surface contaminates on the capillary cell walls) allow sample to "leak" out of the flow cell. This error can only be determined experimentally and is not shown in the tables or chart. Temperature Inaccuracies Temperature directly affects the viscosity of most samples and in particular petroleum‐based samples where the temperature‐viscosity relationship is quite strong. In many cases the viscosity of petroleum‐based lubricating oils decreases approximately 20% for every 5 degree increase in temperature. As a consequence, having tight thermal regulation of the viscometer and the sample under test is paramount to precise viscosity measurements. Nominal Viscosity Percent Viscosity Error due to Temperature Error Viscosity Change mm2/s mm2/s/°C 0.02 °C 0.03 °C 0.04 °C 0.05 °C 0.10 °C 0.20 °C 2 0.03 0.030% 0.045% 0.060% 0.075% 0.150% 0.300% 5 0.08 0.032% 0.048% 0.064% 0.080% 0.160% 0.320% 10 0.27 0.054% 0.081% 0.108% 0.135% 0.270% 0.540% 50 1.90 0.076% 0.114% 0.152% 0.190% 0.380% 0.760% 100 3.70 0.074% 0.111% 0.148% 0.185% 0.370% 0.740% 150 5.00 0.067% 0.100% 0.133% 0.167% 0.333% 0.667% 200 7.00 0.070% 0.105% 0.140% 0.175% 0.350% 0.700% 350 12.00 0.069% 0.103% 0.137% 0.171% 0.343% 0.686% Note: SimpleVIS temperature control accuracy at +/‐0.02 °C and Q3000 accuracy at +/‐0.1°C Page 4 of 7 Analysis of Errors in Viscosity Measurement January 2015 Viscosity Error due to Temperature 0.8% 0.7% 2 0.6% 5 Change 0.5% 10 0.4% 50 Viscosity 0.3% 100 0.2% 150 Percent 0.1% 0.0% 200 0.02 °C 0.03 °C 0.04 °C 0.05 °C 0.10 °C 0.20 °C 350 Temperature Error Contamination or Occlusion of the Capillary The influence of the capillary radius is the most significant contributor (raised to the fourth power) in the Hagen‐Poiseuille equation. Contamination or occlusion of the capillary will result in a decrease of the effective capillary diameter leading to a large measurement error. This contamination can come from a foreign particle in the sample which may become lodged or adhered to the capillary wall or from improper cleaning of the viscometer ‐ such as from lint or dust. The smaller the capillary diameter, the more pronounced the error from contamination as a function of the contaminate size. Capillary Percent Error Due to Contamination or Occlusion in the Capillary Diameter mm 1 micron 2 micron 3 micron 4 micron 5 micron 10 micron 20 micron SimpleVIS 0.72 0.5% 1.1% 1.6% 2.2% 2.7% 5.4% 10.7% Q3000* 0.25 1.6% 3.2% 4.7% 6.2% 7.8% 15.1% 28.4% Note: Q3000 is a non‐conventional rectangular capillary channel unbounded on the sides with an effective diameter of 0.2523 mm. Proper cleaning of the viscometer is critical to maintaining accurate measurements. In instruments such as the Q3000, the capillary can easily be scratched by the wiping cloth which can trap small particles and allow them to be dragged across the polished capillary surfaces. Additionally, contaminates such as lint, dust, hair, or fibers can easily be left on the capillary surface and serve to occlude the flow of subsequent samples being tested. Page 5 of 7 Analysis of Errors in Viscosity Measurement January 2015 Viscosity Error due to Contamination 30% 25% Change 20% 15% SimpleVIS Viscosity 10% Q3000* 5% Percent 0% 123451020 Contamination Particle Size (microns) Sample Charge Volume Inaccuracies The sample charge volume (V) is critical to accurate measurements as it also affects the driving head (H) of the fluid in the capillary. The SimpleVIS operates with a 500 L (0.5 mL) sample charge volume while the Q3000 operates with a 60 L (0.06 mL) sample charge volume. The Q3000 is an order of magnitude more sensitive to small errors in sample volume. The SimpleVIS viscometer system is provided with a ultra‐precise positive‐displacement laboratory style pipettor in which the charge volume is not affected by the sample viscosity. This positive‐ displacement pipette ensures consistent 500 L sample charge volumes regardless of whether low‐viscosity fuel (3 cSt) or high‐viscosity gear oil (680 cSt) is being drawn for testing. In contrast, the Q3000 is supplied with disposable HDPE pipettes in which the actual volume drawn for testing will vary greatly across a wide range of viscosities. This variation in volume can lead to measurement errors as high as 10 to 20 percent – increasing as the sample viscosity increases. Conclusions Bench‐top semi‐automated viscometers can offer a sufficiently accurate measurement for most field operations. These devices often follow the same principles and mimic some of the operation of a typical laboratory‐grade viscometer while eliminating much of the complexity and operator interaction which would require a highly‐trained laboratory technician. However, care must be taken to both understand and mitigate any sources of measurement error. Otherwise errant decisions might be taken on the sample based on an inaccurate viscosity measurement. The operational faults discussed above have varying degrees of influence on measurement error. These faults can be considered additive. For example, one may have alignment, temperature, and contamination faults simultaneously which will cumulatively add to the Page 6 of 7 Analysis of Errors in Viscosity Measurement January 2015 viscosity measurement error. When viscosity measurement precision is critical, care must be taken to control all three operational faults discussed in this paper. If accurate measurement precision is desired, the viscometer system needs to: Provide temperature control of the sample which is better than +/‐ 0.1°C Not be operated at a severe angle (> 10%) with respect to vertical front‐to‐back Not be operated at any angle off vertical side‐to‐side when using the Q3000 Be cleaned and the capillary properly inspected for contaminates before use – especially critical on the Q3000 where a wiping cloth is used to clean the capillary Utilize an accurate device for charging the sample volume into the viscometer Have the calibration periodically verified with a certified viscosity reference standard Page 7 of 7 .
Recommended publications
  • BROOKFIELD DIAL READING VISCOMETER with Electronic Drive
    BROOKFIELD DIAL READING VISCOMETER with Electronic Drive Operating Instructions Manual No. M00-151-I0614 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY with offices in : Boston • Chicago • London • Stuttgart • Guangzhou BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Boulevard, Middleboro, MA 02346 USA TEL 508-946-6200 or 800-628-8139 (USA excluding MA) FAX 508-946-6262 INTERNET http://www.brookfieldengineering.com TABLE OF CONTENTS I. INTRODUCTION .....................................................................................5 I.1 Components .......................................................................................................5 I.2 Utilities ................................................................................................................6 I.3 Specifications .....................................................................................................6 I.4 Set-Up ................................................................................................................7 I.5 IQ, OQ, PQ .........................................................................................................7 I.6 Safety Symbols and Precautions .......................................................................8 I.7 Cleaning .............................................................................................................8 II. GETTING STARTED ..............................................................................9 II.1 Operation ...........................................................................................................9
    [Show full text]
  • HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014]
    HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014] HAAKE Viscometer 7 R+ Location of Machine: Composites Lab, RFM 1218 Location of SOP and Machine Operating & Safety Manual: Composites Lab website under resources; Composites Lab TRACS site; and Hardcopy near machine. Emergency Contact: Call 911 Call EHS & Risk Management at 512-245-3616 Call Head Lab Technician, Dr. Ray Cook (office 512-245-2050) Call Dr. Jitendra S Tate (office 512-245-4872) Before using this machine: You must have permission from Dr. Tate. You must have received formal training from technician or, trained research student (designated by Dr. Tate) related to machine safety and operation. You must read and understand SOP and Machine Cleaning Manual. You must use this machine under direct supervision of Dr. Tate or, Dr. Cook or, trained research student (designated by Dr. Tate). You must have signed “Lab Rules” document with Dr. Tate. This document must be signed every semester fall, spring, and summer (as applicable). If you do NOT follow above instructions you will be held responsible for your own safety and damages. Safety Precautions: Protective Equipment: Prior to performing this procedure, the following personal protective equipment must be obtained and ready for use: Gloves, Safety Goggles, Face Mask, Lab Coat. Important Safeguards: 1. Prior to performing this procedure, the following safety equipment must be accessible and ready for use: (e.g. chemical fume hood, biological safety cabinet, laminar flow hood, chemical spill kits) Fume hood 2. All liquids should be drained to containers for chemical disposal and properly marked. 3. In the event that a hazardous material spill during this procedure, be prepared to clean with cleaner according to MSDS of materials used.
    [Show full text]
  • Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr
    Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr. Maria-Isabel Carnasciali, Dr. Samuel Daniels Abstract This project was an effort to redesign an initial prototype rotational viscometer to experimentally test whether or not viscosity values vary significantly when the geometry of the viscometer is changed. The scope of the project involved designing and building a viscometer that could vary the gap between the inner and outer cylinders, variation of the testing fluid’s temperature, and control of the device’s RPM. After weeks of planning, designing, and fabrication the new viscometer was complete. In order to control the device, monitor the sensor readings, and calculate the testing fluid’s viscosity a LabVIEW program was created. Testing on medium to high viscous fluids was completed to determine if the viscosity values and the geometry of the viscometer are dependent or independent of each other. The results did show a correlation between measured viscosity and variations in the geometry of the viscometer. More testing is required to further verify the results and properly calibrate the device. Introduction For this project a new design was conceptualized, fabricated, and tested. This new design met several criteria including, Viscosity is often referred to as a fluid’s thickness or how much it resists deformation due to an applied force. Designed for future use in ME labs; Rotational viscometers measure the amount of torque needed Designed to be durable, sustainable, and easy to to rotate an object moving through fluid at a known RPM. dissemble and clean; Using the measured torque, RPM, and dimensions of the Multiple inner cylinders for varying gap sizes; device, the viscosity can be calculated using equation 1.
    [Show full text]
  • Miniav®-X Automatic Viscometer Instruction & Operation Manual
    MiniAV®-X Automatic Viscometer Instruction & Operation Manual 81.2254 i CONTENTS 1 INTRODUCTION/INSTALLATION 1 The miniAV®-X Automatic Viscometer .................................................................................. 1 Measuring kinematic viscosity ............................................................................................... 2 Safety cautions ..................................................................................................................... 2 Specifications ....................................................................................................................... 4 Installation ............................................................................................................................ 4 Required installation components ............................................................................... 4 Vacuum Pump unit connections ................................................................................. 6 Bath unit connections ................................................................................................ 6 VISCPRO® for Windows® XP® ............................................................................................ 6 Installing VISCPRO® software .............................................................................................. 7 Computer requirements ............................................................................................. 7 Windows® XP® installation .......................................................................................
    [Show full text]
  • List of Equipments in the Department (Chemical Engineering) Mechanical
    List of Equipments in the Department (Chemical Engineering) Mechanical Operation lab Fluid Mechanics Lab Heat transfer Lab Mass Transfer lab • Cyclone Separator • Reynold’s Apparatus • Double Pipe Heat Exchanger • Tray Dryer • Plate & Frame Filter Press • Bernoulli’s Theorem Apparatus • Shell & Tube Heat Exchanger • Sieve Plate Distillation Column • Vibrating Screen • Pitot Tube Apparatus • Vertical Condenser • Liquid-Liquid Extraction • Jaw Crusher • Calibration of Orifice meter, • Computerized Control Shell & • Adsorption of CO 2 • Ball Mill Venturi meter and Rota meter Tube Heat Exchanger • Steam Distillation • Roll Crusher • Coefficient of Discharge of • Thermal Conductivity of Metal • Bubble Cap Distillation Column • Rotary Vacuum filter Orifice and Mouthpiece Bar • Cooling Tower • Fluidized Bed • Film & Drop Wise Condensation • Diffusivity Apparatus • Single Effect Evaporator • Fluidized Bed Dryer • Simple Steam Distillation • Simple Distillation • VLE Apparatus • Equilibrium Flash Distillation • Humidification & Dehumidification • Refractometer Process Control Lab Chemical Reaction Engg. Lab Fuel Combustion Energy Technology Lab Environmental Lab • Process Training Simulator with • Plug Flow Reactor • Flash & Fire Point Apparatus • BOD Incubator Modules (Software) • Isothermal Batch Reactor • Aniline Point Apparatus • pH Meter • Pressure Control System • Single Tube Packed Bed Reactor • Orsat Gas Analysis Apparatus • Sedimentation Apparatus • Flow Control System • RTD in CSTR / Mixed flow • Redwood Viscometer • UV-VIS Spectrophotometer • pH control System Reactor • Bomb Calorimeter • DO Meter • Real Time Simulator Trainer • RTD in Tubular Reactor • Smoke Point Apparatus • Digital Conductivity Meter • Level Control System • Adiabatic Batch Reactor • Temperature Control System • Distillation Column • Two Tank Interacting system • Two Tank Non-Interacting System • CSTR Control System Research Equipments • UV-Spectrophotometer • Gas Chomatography .
    [Show full text]
  • Department of Chemical Engineering
    DISTILLATION FLASK : Made of borosilicate glass is specified dimension. Capacity: 125 ml. GRADUATED RECEIVER: Capacity : 100 ml. sub-division 1 ml. the cylinder is made of heat resistance borosilicate glass. FLASK SUPPORT ASSEMBLY BOARD: Three asbestos board on each with centre hole 32 mm, 37.5 mm and 50 mm. are provided. TEMPERATURE CONTROLLER: By solid state variable heat controller. Complete Apparatus as described above but supplied with 3 Nos. flask support boards and glassware for operation on 220/230 V, 1ph, 50 c/s, A.C. mains. SPARES FOR ABOVE DISTILLATION APPARATUS: 1. Distillation Flask, borosilicate glass, Capacity : 125 ml. packet of 2(two) pieces. 2. Receiver, 100 ml. packet of 2(two) pieces . 3. Thermometer : Mercury-in-Glass, with NABL Certificate IP – 5C, packet of two pieces.; IP – 6C, packet of two pieces; ASTM – 7C, packet of two pieces. ASTM – 8C, packet of two pieces. 4. Heating Element, packet of two pieces. …………….. 5. Flask support plate, packet of one each (Total 3 nos.) 32 mm. Centre Hole; 37.5 mm. Centre Hole; 50 mm. Centre Hole 2. FLASH POINT PENSKY MARTENS (CLOSED) CONFORMS TO : IS: 1448 & 1209 – 58, IP: 34, ASTM: D-93 SPECIAL FEATURES: Cup & Cover with ebonite handle for operating at high Temperature. For determining the flash point of petroleum products having a flash point above 120º C (48.89º F). The instrument which will give trouble free service under continuous operating conditions. The cast iron air bath is fitted with heaters for uniform heating. An enclosed safety type heater made of nichrome heating element. Temperature is controlled by Digital Temperature Indicator cum controller which ensure smooth and easy control of the temperature.
    [Show full text]
  • Physical Quantity Measured by a Vibration Viscometer (Re: JCSS Standardization of Viscosity)
    Article for the 23rd Sensing Forum Theme: Physical Quantity Measured by a Vibration Viscometer (Re: JCSS Standardization of Viscosity) Presented by: Naoto Izumo R&D Division, A&D Company, Limited October 2 ~ 3, 2006 Tsukuba Center Inc. Tsukuba, JAPAN Physical Quantity Measured by a Vibration Viscometer Subtitle: The JCSS Standardization of Viscosity Naoto Izumo R&D Division, A&D Co., Ltd. Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 Japan Abstract The objective of this article is to introduce a viscometer that utilizes a new viscosimetry measuring method. In addition, the article will recommend a new unit system, which is utilized in the vibration viscometer. Using examples, the article explains JCSS viscosity standardization and recent requirements for viscosity measurements. Keywords: Vibration Viscometer, Static Viscosity (Viscosity × Density), Viscosity JCSS, Cloud Point Introduction The following is an introduction of the vibration viscometer, a new method for measuring viscosity. In addition to providing a description of the physical quantity that is measured using the vibration viscometer, a new unit system for viscosity will be proposed. Furthermore, there is an explanation regarding the Japan Calibration Service System (JCSS) standardization of viscosity and viscosity measurements using actual examples. There is also discussion of recent requirements for measuring viscosity. History and Development of Viscosity Measurement The history of viscosity measurements is extensive and is believed to date back to when people began measuring the viscosities of engine oils with the advent of the automobile industry in the United States. In the U.S., it had become necessary to control the viscosities of engine oils as a method of maintaining the performance of engines.
    [Show full text]
  • QCM Viscometer for Bioremediation and Microbial Activity Monitoring Wesley A
    304 IEEE SENSORS JOURNAL, VOL. 3, NO. 3, JUNE 2003 QCM Viscometer for Bioremediation and Microbial Activity Monitoring Wesley A. Gee, Member, IEEE, Kirsti M. Ritalahti, William D. Hunt, and Frank E. Löffler Abstract—A quartz crystal microbalance has been used to parameter eliminates the necessity of complex data interpreta- monitor the polymer production of a bacterial population in tion of samples by trained technicians. liquid medium. The increasing amount of produced polymer The aim of this study was to show that the QCM is a unique corresponds to an increase in the viscosity of the liquid, which is directly measurable as the fluid contacts the surface of the quartz and effective method to monitor a biological growth process to crystal in the sensor system. This procedure is being developed as aid in characterizing unknown bacterial populations. As a vis- a novel method for measuring microbial polymer production and cometer, this high shear rate device could be used in conjunc- growth of an environmental isolate obtained from river sediment tion with low shear rate laboratory viscosity measurement tech- contaminated with petroleum hydrocarbons. This measurement niques that currently include mechanical (rotational), capillary, technique may be used to monitor growth characteristics of unknown anaerobic bacteria when used in conjunction with falling ball, and other gravity or positive displacement methods. other currently employed microbiological test methods, such as spectrophotometry, to measure turbidity. II. DESCRIPTION OF BACTERIAL STRAIN In the presence of glucose, a novel, strictly anaerobic bacterial isolate, designated strain JEL-1, produces a viscous, as yet uniden- An unusual bacterial population, designated strain JEL-1, tified, polymer.
    [Show full text]
  • LABORATORY Viscometers
    LABORATORY VISCOMETERS www.irmeco.de Viscometer Cannon-Fenske Routine Cannon-Fenske Routine Viscometer according to ASTM D445-446, ASTM D2515, ISO 3104-3105 used for quick and easy measurement of the viscosities of trans- parent Newtonian liquids. Constant value (K) indication at +40°C and +100°C. Made of borosilicate glass, and non-alterable timing marks. Size Nominal Kinematic Art. No. No. viscometer constant viscosity range (mm2/s)/s mm2/s 25 0.002 0.5 to 2 10 15 81025 50 0.004 0.8 to 4 10 15 81050 75 0.008 1.6 to 8 10 15 81075 100 0.015 3 to 15 10 15 81100 150 0.035 7 to 35 10 15 81150 200 0.1 20 to 100 10 15 81200 300 0.25 50 to 250 10 15 81300 350 0.5 100 to 500 10 15 81350 400 1.2 240 to 1200 10 15 81400 450 2.5 500 to 2500 10 15 81450 500 8 1600 to 8000 10 15 81500 600 20 4000 to 20000 10 15 81600 All IRMECO® capillary viscometers are supplied with a Works Calibration Certificate issued in accordance with the conditions of accreditation granted by a National Metrological Register. 2 Viscometer Cannon-Fenske Routine Cannon-Fenske Opaque Cannon-Fenske Opaque Viscometer (reverse flow) according to ASTM D445-446, ASTM D2515, ISO 3104-3105 used for dark Newtonian liquids; especially suitable for liquids so dark in colour that cannot be seen in a Cannon-Fenske routine viscometer. It is also used to study shearing stress and shearing rate.
    [Show full text]
  • Brookfield Digital Viscometer
    BROOKFIELD DIGITAL VISCOMETER MODELDV-1+ Operating Instructions Manual No. M/92-021-A-892 BROOKFIELD ENGINEERING LABORATORIES, INC. 240 Cushing Street, Stoughton, MA 02072 USA Phone: 617-344-4310/4313 800-628-8139 (U.S. except MA); Fax: 617-344-7141 Telex: 924497 BRENLAB STOU (Western Union); 200195 BEL (RCA) TABLE OF CONTENTS L J:N'TRODUCfiON ......................................................................... 3 1 Com:p<>nents ............................................................................ 3 2 Utilities ................................................................................... 4 3 Specifications ......................................................................... 4 4 Set-Up ............................. ;....................................................... 4 S Key Functions ........................................................................ 5 ll. GETTJ:N'G STARTED .................................................................. 6 1 Autozero ................................................................................. 6 2 Spindle Selection .................................................................... 6 3 Speed Selection & Setting ...................................................... 7 4 Autorange Operation .............................................................. 9 S Out of Range Operation ....................................................... 10 Appendix A Cone/Plate Viscometer Set-Up .................................. 11 Appendix B - Viscosity Ranges .......................................................
    [Show full text]
  • Protocol: Measuring Viscosity of Cosmetics with Microvisctm
    Protocol: Measuring Viscosity of Cosmetics with microVISCTM Key Words: Face lotion, hand lotion, cream, viscosity, shear thinning, cleaning, high shear, non-Newtonian fluid, protocol, thixotropy Goal: Cosmetic lotions are often non-Newtonian fluids with yield stresses and thixotropic structure. These properties are vital for their function as selfcare products, but also make their rheological properties difficult to characterize. In particular, data collection can be time consuming and instrument cleaning can be challenging. This application note will share an easy-to-implement protocol to precisely measure complex cosmetic formulations using VROC technology. Introduction Skin care is an important part of personal healthcare. The epidermis is one of the body’s largest organs and is the first line of defense against pathogens, so maintaining and promoting healthy skin is vital for healthy life. Skincare products, specifically lotions, have been used for decades to promote skin health. When developing these products, manufacturers must carefully choose ingredients that must meet both consumer tastes and regulatory standards. These constraints make it vital to characterize lotion formulations, but also these criteria make consistent and fast measurements more challenging. Lotions are comprised of multiple materials including polymers, oils, waxes, gels, and silicones (Sharma et al. 2018). These ingredients can dramatically alter the viscosity of the lotion, but also make measuring viscosity difficult, messy, and variable. The combination of these ingredients can even cause lotions to behave as thixotropic materials. Thixotropy is the time dependent shear thinning property of non-Newtonian fluids (Mewis 1979). Thixotropic materials will slowly return to their high viscosity state once shearing has ceased.
    [Show full text]
  • Visco Handbook THEORY and APPLICATION of VISCOMETRY with GLASS CAPILLARY VISCOMETERS Welcome to SI Analytics!
    Visco handbook THEORY AND APPLICATION OF VISCOMETRY WITH GLASS CAPILLARY VISCOMETERS Welcome to SI Analytics! We express our core competence, namely the production of analytical instruments, with our company name SI Analytics. SI also stands for the main products of our company: sensors and instruments. As part of the history of SCHOTT® AG, SI Analytics has nearly 80 years experience in glass technology and in the development of analytical equipment. As always, our products are manufactured in Mainz with a high level of innovation and quality. Our electrodes, titrators and capillary viscometers will continue to be the right tools in any location where expertise in analytical measurement technology is required. In 2011 SI Analytics became part of the listed company Xylem Inc., headquartered in Rye Brook / N.Y., USA. Xylem is a leading international provider of water solutions. We are pleased to introduce you to the Visco Handbook! It replaces the previous brochure "Theory and Practice of Capillary Viscometry". This has been updated, redesigned and restructured. The information content of some areas such as polymer analysis was increased and specially themed areas such as hydrodynamic principles were moved into their own appendices so as not to deter the reader by too much theory. The focus was placed on the practical and general information needed by each user of capillary viscometry. Both laboratory experiences and policies of the relevant standards are considered here. We thus hope to provide you with a faithful companion for everyday laboratory work, one that you can use profitably. We of SI Analytics are pleased to work with you successfully in the future.
    [Show full text]