Operator's Manual
Total Page:16
File Type:pdf, Size:1020Kb
13 x 100 mm Insert Programmable Run Time is Factory p/n 7713066 Preset to 10 MINUTES See Page 4 SmartView™ Platform p/n 00-079-009-001 Operator’s Manual Model 642M • 12VDC Mobile Laboratory Centrifuge P/N 03-0-0002-0104 Rev. E Table of Contents Model Description ............................... pg. 2 WARNING: Use universal precautions when Intended Use ....................................... pg. 2 handling laboratory specimens. All human specimens Supplied Equipment ............................ pg. 2 of blood, blood compounds, or bo–dily fluids are Technical Specifications ...................... pg. 3 potentially biohazardous and may contain hepatitis Initial Setup Procedure ........................ pg. 3 B virus, hepatitis C virus, human immunodeficiency Front Panel Controls ........................... pg. 4 virus or other disease causing agents. For the safety of Operation ............................................ pg. 5 both the operator and service personnel, care should be taken when handling substances that are known to Tube Holder Configurations ................ pg. 6 be toxic, radioactive, or contaminated with pathogenic Rotor Removal and Installation ........... pg. 7 microorganisms when using this centrifuge. When Care and Maintenance ........................ pg. 7 Risk Group II materials are used Cleaning and Disinfection ................... pg. 8 (As identified in the World Health Organization Troubleshooting ................................... pg. 9 “Laboratory Bio-Safety Manual”) the use of a Bio-Seal Safety .................................................. pg. 10 should be employed. More than one level of protection Emergency Rotor Chamber Entry ....... pg. 10 must be provided in the case of materials of a higher Calibration and Ground Testing ........... pg. 11 group. The use of flammable or explosive materials Replacement Parts .............................. pg. 12 as well as those materials which chemically react Available Accessories ......................... pg. 12 vigorously is prohibited. Any use of the equipment in a manner not specified in these instructions may impair the level protection provided by the equipment. Model Description: The Model 642M is a 12VDC continuous-duty, electronically-controlled horizontal centrifuge intended for mobile applications where the Vehicle has a 12VDC power supply (cigarette lighter). The unit has a lid safety interlock system and is controlled by an electronic push–button timer that has been preset for ten (10) minutes, for precise spin times and ease of use. Samples can be safely viewed through the transparent lid. Entry into the machine is restricted during operation by the safety interlock system. The Model 642M features a lighted control panel that displays the status of the machine, easily viewable from a distance. For warranty information, turn to page 12. Intended Use: This centrifuge is an IVD accessory, and therefore subject to the former EU IVD Directive 98/79/EC and the current EU IVD Regulation 2017/746. It is a laboratory product designed to separate components by generation of relative centrifugal force. It separates human and animal samples – such as blood, urine and other body fluids -- collected in appropriate specimen receptacles, either alone or with reagents or other additives. As a general purpose laboratory centrifuge, it is designed to also run other containers filled with chemicals (non-flammable, non-explosive, non-volatile, and non- highly reactive only), environmental samples, and other non-human body samples. This centrifuge should be operated by trained personnel only. Any use other than those intended by the Manufacturer is explicitly prohibited. [Maximum sample density is 1.15 grams/mL]. Supplied Equipment: The following items come standard with each Model 642M centrifuge: The rotor and rotor accessories are rated for a rotation frequency of 4,000 RPM. 1. One (1) six–place horizontal rotor p/n 7786061 2. Six (6) 100 mm tube holders p/n 7713031 3. Six (6) 75 mm tube holders p/n 7713033 Page 2 Technical Specifications: General Specifications for the Model 642M Centrifuge Voltage: .................................................... 12-24V DC Power: ..................................................... 100 Watts Maximum load: ........................................ 6 x 10mL Maximum Sample Density: ...................... 1.15 grams / mL Nominal Speed (75/100 mm holders): ....... 3,400 (± 175) RPM Nominal RCF (75/100 mm holders): .......... 1,650 xg Environmental Conditions for Use: - For In-vehicle / Indoors only - Ambient temperature: ............................ 2°C - 35°C - Humidity: ............................................... 90% Max Noise: ...................................................... ≤ 65 dB(A) Dimensions: - Height: ................................................... 8.75 in (22 cm) - Width: .................................................... 11.75 in (30 cm) - Depth: .................................................... 14.00 in (35 cm) Weight: .................................................... Approximately 12 lbs. (5.4 kg) Any use other than those specified by the Manufacturer is explicitly prohibited. * Maximum sample density is 1.15 grams / mL, (water density = 1.0 grams / mL) Initial Setup Procedure: If any problems are found during the initial setup procedure, refer to the troubleshooting section of this manual. For further assistance, contact Drucker Diagnostics at 814-342-6205 or 814-692-7661. 1. Plug the power cord into the automobile’s 12V accessory outlet. 2. For safety purposes, the locking system is always activated. To deactivate the system, (in order to insert or retrieve samples), press the ‘OPEN / STOP’ button on the control panel. The ‘UNLOCKED’ indicator light should illuminate. If it does not, refer to the troubleshooting section of this manual. The lid will be unlocked for 15 seconds after pushing the ‘OPEN / STOP’ button. 3. Turn the latch counterclockwise and open the lid. 4. Spin the rotor by hand; check for free and level rotation. If the rotor does not spin freely, refer to the troubleshooting section of this manual. 5. Place the six test tube holders inside the rotor (as shown to the right), and verify that they are seated properly. 6. Close the lid. Rotate the lid knob clockwise to its complete stop position.The ’LATCHED’ indicator light should be illuminated. If it is not, make sure that the lid is latched properly. The centrifuge will not run unless the lid is latched and that the ’LATCHED’ light is on. 7. Turn the centrifuge on by pushing the ‘START’ button. 8. The ‘RUNNING’ indicator light will illuminate. 9. The test tube holders will slide up into the horizontal position and the unit will accelerate to full speed. 10. Listen to the sound of the centrifuge. A smooth whirring sound should be heard. If there are any loud or unusual sounds, stop the centrifuge by pushing the ’OPEN / STOP’ button immediately and refer to the troubleshooting section of this manual. 11. While the machine is running, try to turn the latch counterclockwise. Power may be cut to the motor but you should be unable to fully turn the latch. If it is possible to turn the latch and open the lid while the unit is running, contact Drucker Diagnostics for assistance. Close and latch the lid. Page 3 12. Push the ‘OPEN / STOP’ button. The ‘RUNNING’ indicator light should go out and the motor should slow to a stop. 13. The lid should remain locked until the rotor has nearly stopped. If the machine unlocks prematurely, contact Drucker Diagnostics for assistance. Once the rotor has stopped, the interlock system will become disengaged for sixty (60) seconds. The ‘UNLOCKED’ indicator light will illuminate during this time. 14. To gain entry into the centrifuge after this period has ended, simply press the ‘OPEN / STOP’ button. The lid will unlock for fifteen (15) additional seconds. After the centrifuge has passed this procedure it is ready for operation. Control Panel: ‘LATCHED’ ‘UNLOCKED’ Indicator Light Indicator Light ‘RUNNING’ Model 642M Centrifuge Indicator ‘OPEN / Light STOP’ ‘START’ Button Button ‘RUNNING’ Lights up when the machine ‘START’ Begins a new run, (the lid is in operation, (power03-0-0003-0188 is 642M Drucker Diagnostics must be closed, see pg. 6). beingBlack appliedWhite to theRevision: motor). B Tooling: LT-026 Material: 0.010” Polycarbonate Pantone 288 C Finish: Velvet ‘OPEN / STOP’Allows for access into the ‘LATCHED’ Lights up when theEmbossing lid has Height: 0.010" been closed and latchedAdhesive: FLEXmount® DFV 400 F WHITE V-344 90 PFW rotor chamber by disengaging properly.Pantone 3135 C Note: Supplier must specify materials used on quotes & proofthe locking mechanism. Entry is only permitted when the Clear velvet finish 200 Shady Lane, Suite 170 Pantone 485 C Philipsburg, PA 16866 ‘UNLOCKED’ Lights up to indicate that the (814) 342-6205 Fax: (814) 342-6211rotor is stopped. Pressing this locking mechanism has been www.druckerdiagnostics.com button during operation will deactivated, allowing access terminate the run and unlock to the rotor chamber. the lid after the rotor has come to a stop. Centrifugation Settings: To verify the preset time: a) Push the ‘OPEN / STOP’ button to disengage the lock and then open the lid. b) Push and hold the ‘START’ button for approximately three (3) seconds. The ‘LATCH’ indicator light will begin to flash; indicating verification mode. c) When you release the ‘START’ button, the ‘RUN’ indicator light will begin to flash. Make note of how many times the ‘RUN’ light