Integrated Dehumidification Solution

Total Page:16

File Type:pdf, Size:1020Kb

Integrated Dehumidification Solution Integrated Dehumidification Solution White Paper July 2018 An innovative approach to moisture removal for home health and humidity management Integrated Dehumidification Solution 2 Humidity Issues Impacting Building Health and Comfort Today’s highly energy-efficient homes have While high-performance homes reduce energy highly insulated enclosures and airtight use, the National Renewable Energy Laboratory construction and often require mechanical (NREL) and ventilation to bring fresh air into the indoor Department of environment. These high-performance homes Energy (DOE) conserve resources and save money on heating recognize that and cooling bills, but can suffer negative effects they also have from high humidity levels at certain times of an impact year in a number of U.S. regions. Increased on indoor humidity levels have a significant impact on environments: builders and architects, who are responsible for the health of their buildings, as well as z As homes homeowners, who seek to live in a comfortable, in humid safe indoor environment year-round. climates have Addressing the issue of high humidity requires become a basic understanding of the Home Energy more Rating System (HERS). HERS is the industry energy standard by which home energy performance efficient, is measured—much like the miles-per-gallon there is sticker on cars—giving prospective buyers and evidence homeowners an insight as to how the home that ranks in terms of energy efficiency. A lower relative number indicates a more efficient home: For humidity example, a home built to the 2006 International levels in Energy Conservation Code (IECC) will receive homes have been increasing.2 a rating of around 100, while a more recent home built to 2015 IECC would rate closer to 70. z As heating and cooling loads are shrinking, (Inefficient older homes can have a rating of supplemental dehumidification may be 3 150 or even higher.) Ultimately, the industry is required. pushing toward a net-zero trend—meaning that a home produces as much energy as it consumes through renewable resources.1 CHALLENGE Relative humidity, or the amount of water vapor minimizing these issues, including in homes in the air, is an important health variable that is that are unoccupied for extended periods. easy to overlook, yet very easy to remedy. Ideal For homeowners, high humidity goes beyond humidity is generally described as between 40 affecting the condition of their home’s interior percent and 60 percent. High-humidity indoor and furnishings: When indoor relative humidity environments present several major issues with rises above 60%, occupants of a home are regard to building health and human comfort. going to feel sticky and clammy in addition to Excessive humidity can cause problems with potentially being exposed to the harmful effects odor, mold, and mildew, and even peeling paint, of mold, mildew, bacteria, and dust mites— water damage, or loss of structural integrity making the environment particularly hazardous in the most severe cases. Developers, builders, for people with asthma and allergies. and architects all have a vested interest in 1 HERSindex.com 2 ASHRAE Research Project Report 1449-RP, “Energy Efficient and Cost Assessment of Humidity Control Options for Residential Buildings” 3 National Renewable Energy Laboratory (NREL), “Building America Roadmap Overview: Optimal Comfort Systems for Low-Load Homes” Integrated Dehumidification Solution 3 GEOGRAPHY During the warmest seasons in areas with of spring and fall, when temperatures are in the generally high humidity—such as the Gulf mid-60s and 70s, significantly lower heating Coast and Southeast U.S.—regular heat pump and cooling loads are required. The relative or air conditioning cycles efficiently maintain humidity, however, may be quite high. As a humidity levels; in the coolest seasons, when result, typical indoor moisture sources and outdoor conditions are drier, high humidity is outdoor ventilation air can cause the indoor not an issue. In the so-called shoulder seasons relative humidity to rise to uncomfortable levels. STRIKING A BALANCE Although there are a number of ways and time, and energy usage all must be balanced system types to address excessive relative against building health, human comfort and humidity, there is no silver bullet. Some existing health concerns, and even ease of use. In this solutions require additional system components white paper, we will explain how the Trane such as high-end, whole-home dehumidifiers Integrated Dehumidification Solution (IDS) uses or low-end portable units. Others rely on over- a simple but cost-effective method appropriate cooling to remove humidity from the home, for this segment—servicing an unmet need which can lead to temperature fluctuations up for architects, homebuilders, and homeowners to 3°F off a thermostat set-point, resulting in a number of geographical regions in the in increased energy usage and potential United States. Although it is primarily targeted discomfort. Ultimately, each moisture-removal toward energy-efficient homes, Trane IDS can solution comes with pros and cons, and factors be incorporated into any home in which value- such as initial cost of ownership, payback oriented humidity control is desired. Integrated Dehumidification Solution 4 How The Trane Integrated Dehumidification Solution Works IDS takes a practical approach to the excessive- With IDS, home temperature is maintained humidity problem, pairing a specialized without over-cooling. A heater located within Trane thermostat with compatible Trane air the variable-speed air handler is an independent conditioning units, heat pumps, and variable- operating feature/mode and can be activated speed air handlers. When needed, home when too much humidity is detected, even if occupants can set the thermostat control to cooling is not needed. The result is a more three levels of dehumidification (low/medium/ predictable lowering of humidity all while high), depending on the comfort level desired. maintaining home comfort levels. When too much humidity is detected in the house, the IDS will run for a defined amount In basic terms, the IDS uses the of time out of each hour. (Note: To adhere to dehumidification function of the cooling coils code requirements, IDS is only available when in conjunction with the warming function of the system is in cooling mode. See Appendix for electric heat in order to remove moisture while additional detail.) maintaining neutral, comfortable temperatures within the home. 1 ndoor idiy ee inree de o inern ore or oi ir rog in ro e oide 1 2 ero dee idiy eeed e ere reerene o o edi or 4 ig deending on deired oor ee nd ond 2 e ye o rn on ooing 5 eeri e nd e rie eed ir 3 nder 5 er reded 3 e ye oiy idiy in e oe e ene e need o reoe ero onine o oire nd e ooed ir onior idiy ee nd e oer e eeri eing e r onino n eeen iin e ir nder ere i oiy nd i red o e e iro den o eerre o e oe 4 e ir nder en reen ny oire on e roiding onino oor ire e drier ondiioned oi or in e drin n ro ir rogo e oe ie reeoring nd eing oere inroded ino e oe IDS System Components Unique XL824 or XL1050 Control Outdoor Variable Speed Heat Pump or Indoor Mechanical Ventilator Air Conditioner Air Handler (not required in all homes) Integrated Dehumidification Solution 5 Why Trane IDS is Needed and the Benefits It Provides The market needs a technology that will provide year-round comfort in energy-efficient homes at the lowest upfront cost. There are two specific customer groups that can benefit from incorporating Trane IDS into their HVAC systems: RESIDENTIAL BUILDERS/ARCHITECTS The home construction industry is acutely aware of the problems caused by high indoor humidity levels, both from the perspective of homeowner satisfaction as well as the health of their buildings when vacant, prior to purchase. For those designing and building residential homes, Trane IDS represents a cost-effective option for basic dehumidification, given the low initial price and simple, fast installation. z Numerous builders and architects have requested Trane’s assistance to address these concerns. Trane IDS provides a value-oriented, integrated solution that makes financial and practical sense: z Lower initial cost of systems, due to use of existing Trane HVAC units that are compatible— rather than having to purchase separate equipment and accessories. z Similarly, use of those familiar product lines simplifies installation, minimizing labor costs and time on-site. z Effective removal of humidity from vacant homes protects their investment from hazards of mold, mildew, and odors, as well as the resulting callback issues. z More comfortable indoor climates result in increased homeowner satisfaction. HOMEOWNERS Occupants of energy-efficient homes need fresh air, but they also want to be comfortable and protected from issues such as mold, mildew, and odors. During winter and summer in humid regions of the United States, HVAC units effectively remove moisture from the air. During the shoulder seasons, when temperatures are moderate and homes require less heating or cooling, indoor humidity can rise to uncomfortable levels. For value-minded homeowners, Trane IDS provides several advantages: z Low initial cost of ownership. (See additional discussion below.) z Whole-house dehumidification through existing ductwork. z Creates more comfortable environment. z Mitigates health issues from mold and mildew. z Ease of use—interaction done with familiar thermostat programming via simple user interface offers low- medium-high levels, keeping relative humidity under 60% and as low as 45%4. z No maintenance required beyond regular servicing of the standard equipment. 4 The relative humidity in individual homes will vary based on outdoor conditions and installation. If more specific set points are desired, another solution—such as a whole-house dehumidifier—may be recommended.
Recommended publications
  • DSM Pocket Guidebook Volume 1: Residential Technologies DSM Pocket Guidebook Volume 1: Residential Technologies
    IES RE LOG SIDE NO NT CH IA TE L L TE A C I H T N N E O D L I O S G E I R E S R DSML Pocket Guidebook E S A I I D VolumeT 1: Residential Technologies E N N E T D I I A S L E R T E S C E H I N G O O L L O O G N I H E C S E T R E L S A I I D T E N N E T D I I A S L E R T E S C E H I N G O O L Western Area Power Administration August 2007 DSM Pocket Guidebook Volume 1: Residential Technologies DSM Pocket Guidebook Volume 1: Residential Technologies Produced and funded by Western Area Power Administration P.O. Box 281213 Lakewood, CO 80228-8213 Prepared by National Renewable Energy Laboratory 1617 Cole Boulevard Golden, CO 80401 August 2007 Table of Contents List of Tables v List of Figures v Foreword vii Acknowledgements ix Introduction xi Energy Use and Energy Audits 1 Building Structure 9 Insulation 10 Windows, Glass Doors, and Sky lights 14 Air Sealing 18 Passive Solar Design 21 Heating and Cooling 25 Programmable Thermostats 26 Heat Pumps 28 Heat Storage 31 Zoned Heating 32 Duct Thermal Losses 33 Energy-Efficient Air Conditioning 35 Air Conditioning Cycling Control 40 Whole-House and Ceiling Fans 41 Evaporative Cooling 43 Distributed Photovoltaic Systems 45 Water Heating 49 Conventional Water Heating 51 Combination Space and Water Heaters 55 Demand Water Heaters 57 Heat Pump Water Heaters 60 Solar Water Heaters 62 Lighting 67 Incandescent Alternatives 69 Lighting Controls 76 Daylighting 79 Appliances 83 Energy-Efficient Refrigerators and Freezers 89 Energy-Efficient Dishwashers 92 Energy-Efficient Clothes Washers and Dryers 94 Home Offices
    [Show full text]
  • What Is a Typical Energy Consumption?
    What is a typical Energy Consumption? • Information in the public domain about ‘average’ consumption • Averages are made from many different variations! The Australian Energy Market Commission The Victorian Government Typical energy consumption depends on: • The number of people • The type of housing • The energy mix • The lifestyle • Information in the following graphics is supplied by switchon.gov.vic.au Household 1 Occupants Energy Type Dwelling Type Household includes: Electric hot water Electric heating and cooling Electric cooking Swimming pool All Electric House 2 plasma TV 3 computers Dishwasher Annual power cost: $3,289.64 Clothes dryer 15,014.8 kWh What is the breakdown? • Every household is different, but an ‘average’ gives a basic idea of where it could be consumed • This household uses an average of 41 kWh per day, average cost = $9.01 per day • Heating and cooling is not used all year round, so real ‘daily’ consumption is much higher A ‘ball-park’ break-down of energy use Source: DPI Switch On website/Baseline Energy Estimates 2008, DEWHA ‘Household 1’ Type of consumption Percentage Kilowatt-hours per day Stand-by power 3 1.2 Heating and cooling 38 15.6 Water heating 25 10.3 Other appliances (including pool) 16 6.6 Fridges and freezers 7 2.9 Lighting 7 2.9 Cooking 4 1.6 Total 100% 41.1 kWh/day Household 2 Occupants Energy Type Dwelling Type Household includes: Electric hot water Electric heating and cooling Electric cooking Plasma TV All Electric House Computer Dishwasher Clothes dryer Annual power cost: $1,808.54
    [Show full text]
  • Electric Heating Load Forecasting Method Based on Improved Thermal Comfort Model and LSTM
    energies Article Electric Heating Load Forecasting Method Based on Improved Thermal Comfort Model and LSTM Jie Sun 1, Jiao Wang 1, Yonghui Sun 1, Mingxin Xu 1, Yong Shi 1, Zifa Liu 2 and Xingya Wen 2,* 1 State Grid Inner Mongolia Eastern Electric Power Co., Ltd., Economic and Technical Research Institute, Hohhot 010011, China; [email protected] (J.S.); [email protected] (J.W.); [email protected] (Y.S.); [email protected] (M.X.); [email protected] (Y.S.) 2 School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China; [email protected] * Correspondence: [email protected]; Tel.: +86-18810119275 Abstract: The accuracy of the electric heating load forecast in a new load has a close relationship with the safety and stability of distribution network in normal operation. It also has enormous implications on the architecture of a distribution network. Firstly, the thermal comfort model of the human body was established to analyze the comfortable body temperature of a main crowd under different temperatures and levels of humidity. Secondly, it analyzed the influence factors of electric heating load, and from the perspective of meteorological factors, it selected the difference between human thermal comfort temperature and actual temperature and humidity by gray correlation analysis. Finally, the attention mechanism was utilized to promote the precision of combined adjunction model, and then the data results of the predicted electric heating load were obtained. In the verification, the measured data of electric heating load in a certain area of eastern Inner Mongolia were used. The results showed that after considering the input vector with most relative factors such as temperature and human thermal comfort, the LSTM network can realize the accurate prediction of the electric Citation: Sun, J.; Wang, J.; Sun, Y.; Xu, M.; Shi, Y.; Liu, Z.; Wen, X.
    [Show full text]
  • CK & CKT 15 E Surface-Mounted Electric Fan Heaters | Engineering Specification Sheet
    ENGINEERING SPECIFICATION SHEET Simply the Best CK & CKT 15 E Surface-Mounted Electric Fan Heaters Description Stiebel Eltron CK wall-mounted electric heaters are designed for installation where quick heat is needed, such as bathrooms, kitchens, bedrooms, hallways, playrooms and garages in new construction and renovation projects. They have an ultra-quiet fan and will replace existing recess- mount heaters. A built-in thermostat has a frost protection setting. CK heaters will work with wall thermostats in rooms larger than 215 sq. ft. (20 sq. m.) The CKT adds a 60 minute timer designed to temporarily output maximum heat to quickly warm a space. When the timer goes off the unit CK without timer reverts to the thermostat setting to maintain comfort. CKT with timer Specifications Model Item number CK 15 E 074058 CKT 15 E 230345 Phase single Voltage 120 V Wattage 1500 W Amperage 12.5 A Rated output 5122 Btu/hr Certified to ANSI/UL Air volume 106 cfm Std. 2021 Recommended circuit breaker size 15 A Conforms to CAN/CSA Minimum wire size 14 AWG Std. 22.2 No. 46 Heating element nichrome wire Thermostat bimetal type High limit bimetal type Motor 18 W shaded pole Blower galvanized steel, squirrel cage type Dimensions HEIGHT 18˝ (460 mm) x WIDTH 13¼˝ (335 mm) x DEPTH 4⅞˝ (123 mm) Weight 8.0 lb (4.4 kg) Housing stove enameled sheet steel / plastic Color Alpine White with black grill Due to our continuous process of engineering and technological advancement, specifications may change without notice. Temperature range 45 – 86 °F (7 – 30 °C) | Frost protection setting 45 °F (7 °C) Operating noise 49.7 dB(a) rev.
    [Show full text]
  • Design of a Heat Pump Assisted Solar Thermal System Kyle G
    Purdue University Purdue e-Pubs International High Performance Buildings School of Mechanical Engineering Conference 2014 Design of a Heat Pump Assisted Solar Thermal System Kyle G. Krockenberger Purdue University, United States of America / Department of Mechanical Engineering Technology, [email protected] John M. DeGrove [email protected] William J. Hutzel [email protected] J. Christopher Foreman [email protected] Follow this and additional works at: http://docs.lib.purdue.edu/ihpbc Krockenberger, Kyle G.; DeGrove, John M.; Hutzel, William J.; and Foreman, J. Christopher, "Design of a Heat Pump Assisted Solar Thermal System" (2014). International High Performance Buildings Conference. Paper 146. http://docs.lib.purdue.edu/ihpbc/146 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 3572 , Page 1 Design of a Heat Pump Assisted Solar Thermal System Kyle G. KROCKENBERGER 1*, John M. DEGROVE 1*, William J. HUTZEL 1, J. Chris FOREMAN 2 1Department of Mechanical Engineering Technology, Purdue University, West Lafayette, Indiana, United States. [email protected], [email protected], [email protected] 2Department of Electrical and Computer Engineering Technology, Purdue University, West Lafayette, Indiana, United States. [email protected] * Corresponding Author ABSTRACT This paper outlines the design of an active solar thermal loop system that will be integrated with an air source heat pump hot water heater to provide highly efficient heating of a water/propylene glycol mixture.
    [Show full text]
  • Calorex Non-Ducted Swimming Pool Dehumidifiers
    Image kindly supplied by Origin Leisure Calorex non-ducted swimming pool dehumidifiers Take control of your swimming pool environment Ideal for indoor pool applications including Domestic, Therapy, Health Clubs and Hotel & Spa pools, the Calorex range of non-ducted dehumidifiers, are the only choice when it comes to efficiency, reliability and performance. Protect your pool building Calorex dehumidifiers cleverly convert the energy Using a Calorex dehumidifier minimises the need to locked up in the moisture into heat used to heat the introduce and heat the cold outdoor air into the pool An indoor swimming pool is a wonderful leisure room. The free heat recovered by dehumidification hall to dehumidify, which can be costly. and exercise environment, but there are many is not only “green”, but it accelerates the drying important factors to consider when planning and process, keeps the boiler off for longer, reduces Models designing a pool. the evaporation from the pool and creates a warm Available as wall mount or through wall Even when you cannot see it, moisture in the form dry environment. models (TTW), for installation outside of the of water vapour is all around us in the air. The pool hall, the Calorex range of dehumidifiers also humidity in the air, if not controlled, will cause Efficient offer air heating via LPHW (low pressure hot water) corrosion, mould and bacteria growth. Calorex dehumidifiers are exceptionally efficient, or Electric Resistance Heating. recovering the latent energy that is contained in the When left unchecked, moisture damage in The dehumidifiers within this brochure are moisture and delivering it back to the pool hall in swimming pool buildings causes major subject to a 2 year manufacturer’s warranty, the form of heat.
    [Show full text]
  • Thermal Calculation and Experimental Investigation of Electric Heating and Solid Thermal Storage System
    energies Article Thermal Calculation and Experimental Investigation of Electric Heating and Solid Thermal Storage System Haichuan Zhao 1, Ning Yan 1,*, Zuoxia Xing 1, Lei Chen 1 and Libing Jiang 2 1 School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China; [email protected] (H.Z.); [email protected] (Z.X.); [email protected] (L.C.) 2 Shenyang Lanhao New Energy Technology Company, Shenyang 110006, China; [email protected] * Correspondence: [email protected]; Tel.: +86-159-0982-6968 Received: 7 August 2020; Accepted: 2 October 2020; Published: 9 October 2020 Abstract: Electric heating and solid thermal storage systems (EHSTSSs) are widely used in clean district heating and to flexibly adjust combined heat and power (CHP) units. They represent an effective way to utilize renewable energy. Aiming at the thermal design calculation and experimental verification of EHSTSS, the thermal calculation and the heat transfer characteristics of an EHSTSS are investigated in this paper. Firstly, a thermal calculation method for the EHSTSS is proposed. The calculation flow and calculation method for key parameters of the heating system, heat storage system, heat exchange system and fan-circulating system in the EHSTSS are studied. Then, the instantaneous heat transfer characteristics of the thermal storage system (TSS) in the EHSTSS are analyzed, and the heat transfer process of ESS is simulated by the FLUENT 15 software. The uniform temperature distribution in the heat storage and release process of the TSS verifies the good heat transfer characteristics of the EHSTSS. Finally, an EHSTSS test verification platform is built and the historical operation data of the EHSTSS is analyzed.
    [Show full text]
  • Building Envelope and Thermal Storage
    Energies 2012, 5, 3972-3985; doi:10.3390/en5103972 OPEN ACCESS energies ISSN 1996-1073 www.mdpi.com/journal/energies Article Residential Solar-Based Seasonal Thermal Storage Systems in Cold Climates: Building Envelope and Thermal Storage Alexandre Hugo 1 and Radu Zmeureanu 2,* 1 Halsall Associates, 2300 Yonge Street, Suite 2300 Toronto, Ontario M4P 1E4, Canada; E-Mail: [email protected] 2 Department of Building, Civil and Environmental Engineering, Faculty of Engineering and Computer Science, Concordia University, Montréal, Québec H3G 1M8, Canada * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +1-514-848-2424 (ext. 3203); Fax: +1-514-848-7965. Received: 21 August 2012; in revised form: 26 September 2012 / Accepted: 8 October 2012 / Published: 16 October 2012 Abstract: The reduction of electricity use for heating and domestic hot water in cold climates can be achieved by: (1) reducing the heating loads through the improvement of the thermal performance of house envelopes, and (2) using solar energy through a residential solar-based thermal storage system. First, this paper presents the life cycle energy and cost analysis of a typical one-storey detached house, located in Montreal, Canada. Simulation of annual energy use is performed using the TRNSYS software. Second, several design alternatives with improved thermal resistance for walls, ceiling and windows, increased overall air tightness, and increased window-to-wall ratio of South facing windows are evaluated with respect to the life cycle energy use, life cycle emissions and life cycle cost. The solution that minimizes the energy demand is chosen as a reference house for the study of long-term thermal storage.
    [Show full text]
  • Are You Considering Electric Heating? Go for Our Conforto Furnaces
    ARE YOU CONSIDERING ELECTRIC HEATING? GO FOR OUR CONFORTO FURNACES HIBOY SERIES KHE & LOWBOY SERIES KLE • ComfortMax Modulation feature: - Targets ideal length of time in a heating cycle to ensure constant even temperatures. - Automatically adjusts heat output to prevent overshooting the thermostat set point, thereby providing energy savings plus comfort. - Automatic multi-staged heating for those chilly days. - Provides full heating capacity on those colder days. • Quiet Comfort feature: - During continuous low speed fan operation, this feature will activate one of the heating elements at 50% of its capacity for a maximum period of three hours unless a call for heat is made by the thermostat. - Will maintain a more even and comfortable ambient temperature. • Two-stage a/c plus heat pump ready. • Optional high efficiency ECM motors. LOWBOY SERIES KLE • The KLE format allows quick and easy replacement NEW VERSION onto existing lowboy oil furnace, while ensuring optimal performance. • Two stage a/c plus heat pump ready. • Optional high efficiency ECM motor. KHE Electric Furnace KLE Electric Furnace CONTINUOUS MODULATION TECHNOLOGY GREAT WARRANTIES FOR GREATER SAVINGS The technologically advanced electric 5-year warranty on all furnaces, KHE & KLE are designed with electrical components. Adapt the heating power to the building’s a state-of-the-art electronic control. heat loss. With Conforto’s power modulation, PEACE OF MIND only the required amount of energy will WIDE RANGE With 64+ years of experience, Granby be used to supply the heating load. Total Our Conforto series have ratings Industries is known for its quality products and heating costs are thus optimized throughout ranging from 10 to 27 KW.
    [Show full text]
  • Home Heating and Cooling 2
    iowa energy center Home Series Home Heating and Cooling 2 Reduce your utility bills with low-cost, low-tech tips Get more heat from every energy dollar you spend—page 3 Make the most of your air-conditioning system—page 10 Landscape your yard for year-round comfort—page 19 Save with a whole-house approach Every year, a typical family in the United States spends around half of its home Did you know? energy budget on heating and cooling. In Iowa, that percentage can be higher, due The Energy Independence and to temperature extremes reached during the winter and summer months. Security Act of 2007 sets the Unfortunately, many of those dollars often are wasted, because conditioned air stage for significant changes in escapes through leaky ceilings, walls and foundations—or flows through energy policy across the United inadequately insulated attics, exterior walls and basements. In addition, many States for many years to come. During the next several years, new heating systems and air conditioners aren’t properly maintained or are more than energy-efficiency standards will 10 years old and very inefficient, compared to models being sold today. be put into place for appliances, As a result, it makes sense to analyze your home as a collection of systems that furnace motors, residential boilers and other energy-using devices. So, must work together in order to achieve peak energy savings. For example, you won’t watch for the latest news about tax get anywhere near the savings you’re expecting from a new furnace if your air- credits for homeowners who make handling ducts are uninsulated and leak at every joint.
    [Show full text]
  • CO Residential HVAC Rebates Completed Improvement Checklist
    Application Colorado CO Residential HVAC Rebates Completed Improvement Checklist Furnace Evaporative cooler Natural gas water heater Mini-split heat pump Smart thermostat Account information Xcel Energy account number where unit was installed ___________________________________________ Phone ____________________________ Account holder name (as shown on your utility bill) __________________________________________________________________________________ Installation address ____________________________________________ City ____________________________ State ______ ZIP ____________ Email address _____________________________________________________________________________________________________________ Mailing address (if different) ______________________________________________________________ County ___________________________ Account holder hereby certifies that 1. the account holder is solely responsible for the accuracy of the application information; 2. all installation is complete and operational prior to submitting thisapplication; 3. all rules of this Xcel Energy program (listed on back) have been followed; 4. Xcel Energy is not liable for any work performed. Account holder signature _________________________________________________________________ Date _____________________________ Rebate payment option (if no option is chosen, the rebate will default to a check) Check (rebate check will be mailed) Bill credit (rebate will be applied as a credit to the Xcel Energy account) Direct deposit (ACH Payments are available to customer
    [Show full text]
  • The KFS Series Electric Furnace the KFS Series Furnace Is the Quietest and Most Compact Unit Available in Its Class
    Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20 - 208V 24 - 240V 48 - 480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Baked enamel finish Manual reset limit on 20 kW and larger Direct drive motor Fan relay Welded galvanized steel construction Up to 3-speed motor Silent contactors Thermally protected motor Standard 24 Volt control Sequenced elements Replaceable filter Horizontal or vertical mount Dual inlet blower Mobile home approved Insulated discharge cabinet 60 Amp disconnect protection (KFS) 5 Year limited warranty The KFS Series Electric Furnace The KFS Series furnace is the quietest and most compact unit available in its class. Ideal for residential applications, and yet powerful enough for commercial and process heating applications as well. It’s the perfect choice for both new and replacement installations. The compact design allows it to be installed in either upflow, downflow or horizontal applications. Featuring a maintenance free blower, an insulated cabinet for quiet operation, and heavy gauge coiled nickel-chromium wire heating elements, the KFS furnace will provide years of trouble-free operation. DOWNFLOW UPFLOW Return Exhaust 1” discharge sub base Part No. KFSSB Return Cross Flow Exhaust Engineering Specifications Contractor shall supply and install KFS Series electric furnaces manufactured by King Electrical Mfg. Company. Furnaces shall be of the wattage and voltage as indicated on the plans. Overcurrent Protection: 208 and 240 volt KFS models have 60 amp circuit breakers. 480, 208 and 240 volt KF models have Transformer: Each furnace is equipped with a heavy-duty low voltage terminal blocks.
    [Show full text]