Custom Fabrication and Mode-Locked Operation of a Femtosecond Fiber
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Second Harmonic Imaging Microscopy
170 Microsc Microanal 9(Suppl 2), 2003 DOI: 10.1017/S143192760344066X Copyright 2003 Microscopy Society of America Second Harmonic Imaging Microscopy Leslie M. Loew,* Andrew C. Millard,* Paul J. Campagnola,* William A. Mohler,* and Aaron Lewis‡ * Center for Biomedical Imaging Technology, University of Connecticut Health Center, Farmington, CT 06030-1507 USA ‡ Division of Applied Physics, Hebrew University of Jerusalem, Jerusalem 91904, Israel Second Harmonic Generation (SHG) has been developed in our laboratories as a high- resolution non-linear optical imaging microscopy (“SHIM”) for cellular membranes and intact tissues. SHG is a non-linear process that produces a frequency doubling of the intense laser field impinging on a material with a high second order susceptibility. It shares many of the advantageous features for microscopy of another more established non-linear optical technique: two-photon excited fluorescence (TPEF). Both are capable of optical sectioning to produce 3D images of thick specimens and both result in less photodamage to living tissue than confocal microscopy. SHG is complementary to TPEF in that it uses a different contrast mechanism and is most easily detected in the transmitted light optical path. It also does not arise via photon emission from molecular excited states, as do both 1- and 2-photon excited fluorescence. SHG of intrinsic highly ordered biological structures such as collagen has been known for some time but only recently has the full potential of high resolution 3D SHIM been demonstrated on live cells and tissues. For example, Figure 1 shows SHIM from microtubules in a living organism, C. elegans. The images were obtained from a transgenic nematode that expresses a ß-tubulin-green fluorescent protein fusion and Figure 1 also shows the TPEF image from this molecule for comparison. -
Multiphoton Microscopy
Living up to Life Multiphoton Microscopy 1 Jablonski Diagram: Living up to Life Nonlinear Optical Microscopy F.- Helmchen, W. Denk, Deep tissue two-photon microscopy, Nat. Methods 2, 932-940 2 Typical Samples – Living up to Life Small Dimensions & Highly Scattering • Somata 10-30 µm • Dendrites 1-5 µm • Spines ~0.5 µm • Axons 1-2 µm ls ~ 50-100 µm (@ 630 nm) ls ~ 200 µm (@ 800 nm) T. Nevian Institute of Physiology University of Bern, Switzerland F.- Helmchen, W. Denk Deep tissue two-photon microscopy. Nat. Methods 2, 932-940 3 Why Multiphoton microscopy? Living up to Life • Today main challenge: To go deeper into samples for improved studies of cells, organs or tissues, live animals Less photodamage, i.e. less bleaching and phototoxicity • Why is it possible? Due to the reduced absorption and scattering of the excitation light 4 The depth limit Living up to Life • Achievable depth: ~ 300 – 600 µm • Maximum imaging depth depends on: – Available laser power – Scattering mean-free-path – Tissue properties • Density properties • Microvasculature organization • Cell-body arrangement • Collagen / myelin content – Specimen age – Collection efficiency Acute mouse brain sections containing YFP neurons,maximum projection, Z stack: 233 m Courtesy: Dr Feng Zhang, Deisseroth laboratory, Stanford University, USA Page 5 What is Two‐Photon Microscopy? Living up to Life A 3-dimensional imaging technique in which 2 photons are used to excite fluorescence emission exciting photon emitted photon S1 Simultaneous absorption of 2 longer wavelength photons to -
Adaptive Optics in Microscopy
Downloaded from http://rsta.royalsocietypublishing.org/ on February 3, 2015 Phil. Trans. R. Soc. A (2007) 365, 2829–2843 doi:10.1098/rsta.2007.0013 Published online 13 September 2007 Adaptive optics in microscopy BY MARTIN J. BOOTH* Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK The imaging properties of optical microscopes are often compromised by aberrations that reduce image resolution and contrast. Adaptive optics technology has been employed in various systems to correct these aberrations and restore performance. This has required various departures from the traditional adaptive optics schemes that are used in astronomy. This review discusses the sources of aberrations, their effects and their correction with adaptive optics, particularly in confocal and two-photon microscopes. Different methods of wavefront sensing, indirect aberration measurement and aberration correction devices are discussed. Applications of adaptive optics in the related areas of optical data storage, optical tweezers and micro/nanofabrication are also reviewed. Keywords: adaptive optics; aberrations; confocal microscopy; multiphoton microscopy; optical data storage; optical tweezers 1. Introduction Optical microscopes are essential tools in many scientific fields. In the life sciences, they are widely used for the visualization of cellular structures and sub- cellular processes. Confocal and multiphoton microscopes are particularly important in this respect as they produce three-dimensional images of volumetric objects. However, the resolution of these microscopes is often adversely affected by the optical properties of the specimen itself. Spatial variations in the refractive index of the specimen introduce optical aberrations that compromise image quality. This is a particular problem when imaging deep into thick biological specimens. -
Fv1000 Fluoview
Confocal Laser Scanning Biological Microscope FV1000 FLUOVIEW FLUOVIEW—Always Evolving FLUOVIEW–—From Olympus is Open FLUOVIEW—More Advanced than Ever The Olympus FLUOVIEW FV1000 confocal laser scanning microscope delivers efficient and reliable performance together with the high resolution required for multi-dimensional observation of cell and tissue morphology, and precise molecular localization. The FV1000 incorporates the industry’s first dedicated laser light stimulation scanner to achieve simultaneous targeted laser stimulation and imaging for real-time visualization of rapid cell responses. The FV1000 also measures diffusion coefficients of intracellular molecules, quantifying molecular kinetics. Quite simply, the FLUOVIEW FV1000 represents a new plateau, bringing “imaging to analysis.” Olympus continues to drive forward the development of FLUOVIEW microscopes, using input from researchers to meet their evolving demands and bringing “imaging to analysis.” Quality Performance with Innovative Design FV10i 1 Imaging to Analysis ing up New Worlds From Imaging to Analysis FV1000 Advanced Deeper Imaging with High Resolution FV1000MPE 2 Advanced FLUOVIEW Systems Enhance the Power of Your Research Superb Optical Systems Set the Standard for Accuracy and Sensitivity. Two types of detectors deliver enhanced accuracy and sensitivity, and are paired with a new objective with low chromatic aberration, to deliver even better precision for colocalization analysis. These optical advances boost the overall system capabilities and raise performance to a new level. Imaging, Stimulation and Measurement— Advanced Analytical Methods for Quantification. Now equipped to measure the diffusion coefficients of intracellular molecules, for quantification of the dynamic interactions of molecules inside live cell. FLUOVIEW opens up new worlds of measurement. Evolving Systems Meet the Demands of Your Application. -
FABRICATION of TRANSPARENT CERAMIC LASER MEDIA for HIGH ENERGY LASER APPLICATIONS Karn Serivalsatit Clemson University, [email protected]
Clemson University TigerPrints All Dissertations Dissertations 5-2010 FABRICATION OF TRANSPARENT CERAMIC LASER MEDIA FOR HIGH ENERGY LASER APPLICATIONS Karn Serivalsatit Clemson University, [email protected] Follow this and additional works at: https://tigerprints.clemson.edu/all_dissertations Part of the Materials Science and Engineering Commons Recommended Citation Serivalsatit, Karn, "FABRICATION OF TRANSPARENT CERAMIC LASER MEDIA FOR HIGH ENERGY LASER APPLICATIONS" (2010). All Dissertations. 525. https://tigerprints.clemson.edu/all_dissertations/525 This Dissertation is brought to you for free and open access by the Dissertations at TigerPrints. It has been accepted for inclusion in All Dissertations by an authorized administrator of TigerPrints. For more information, please contact [email protected]. FABRICATION OF TRANSPARENT CERAMIC LASER MEDIA FOR HIGH ENERGY LASER APPLICATIONS A Dissertation Presented to the Graduate School of Clemson University In Partial Fulfillment of the Requirements for the Degree Doctor of Philosophy Materials Science and Engineering by Karn Serivalsatit May 2010 Accepted by: Dr. John Ballato, Committee Chair Dr. Stephen Foulger Dr. Jian Luo Dr. Eric Skaar i ABSTRACT Sesquioxides of yttrium, scandium, and lutetium, i.e., Y2O3, Sc 2O3, and Lu 2O3, have received a great deal of recent attention as potential high power solid state laser hosts. These oxides are receptive to lanthanide doping, including trivalent Er, Ho and Tm which have well known emissions at eye-safe wavelengths that can be excited using commercial diode lasers. These sesquioxides are considered superior to the more conventional yttrium aluminum garnet (YAG) due to their higher thermal conductivity, which is critical for high power laser system. Unfortunately, these oxides possess high melting temperatures, which make the growth of high purity and quality crystals using melt techniques difficult. -
Construction of a Flashlamp-Pumped Dye Laser and an Acousto-Optic
; UNITED STATES APARTMENT OF COMMERCE oUBLICATION NBS TECHNICAL NOTE 603 / v \ f ''ttis oi Construction of a Flashlamp-Pumped Dye Laser U.S. EPARTMENT OF COMMERCE and an Acousto-Optic Modulator National Bureau of for Mode-Locking Iandards — NATIONAL BUREAU OF STANDARDS 1 The National Bureau of Standards was established by an act of Congress March 3, 1901. The Bureau's overall goal is to strengthen and advance the Nation's science and technology and facilitate their effective application for public benefit. To this end, the Bureau conducts research and provides: (1) a basis for the Nation's physical measure- ment system, (2) scientific and technological services for industry and government, (3) a technical basis for equity in trade, and (4) technical services to promote public safety. The Bureau consists of the Institute for Basic Standards, the Institute for Materials Research, the Institute for Applied Technology, the Center for Computer Sciences and Technology, and the Office for Information Programs. THE INSTITUTE FOR BASIC STANDARDS provides the central basis within the United States of a complete and consistent system of physical measurement; coordinates that system with measurement systems of other nations; and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scien- tific community, industry, and commerce. The Institute consists of a Center for Radia- tion Research, an Office of Measurement Services and the following divisions: Applied Mathematics—Electricity—Heat—Mechanics—Optical Physics—Linac Radiation 2—Nuclear Radiation 2—Applied Radiation 2—Quantum Electronics 3— Electromagnetics 3—Time and Frequency 3 —Laboratory Astrophysics3—Cryo- 3 genics . -
Tunable, Low-Repetition-Rate, Cost-Efficient Femtosecond Ti:Sapphire Laser for Nonlinear Microscopy
Appl Phys B (2012) 107:17–22 DOI 10.1007/s00340-011-4830-7 Tunable, low-repetition-rate, cost-efficient femtosecond Ti:sapphire laser for nonlinear microscopy P.G. Antal · R. Szipocs˝ Received: 29 July 2011 / Revised version: 26 September 2011 / Published online: 25 November 2011 © Springer-Verlag 2011 Abstract We report on a broadly tunable, long-cavity light intensity sufficient for nonlinearities, ultrashort (fs or Ti:sapphire laser oscillator being mode-locked in the net ps) pulse mode-locked lasers are used as light sources, most negative intracavity dispersion regime by Kerr-lens mode- often femtosecond pulse, tunable Ti:sapphire lasers having locking, delivering τFWHM < 300 fs pulses at 22 MHz rep- a repetition rate at around 80 MHz. etition rate. The wavelength of the laser can be tuned over Multiphoton transitions of intracellular fluorophores used a 170 nm wide range between 712 nm and 882 nm. Hav- in microscopy can be efficiently excited in the 700–1200 nm ing a typical pump power of 2.6 W, the maximum pulse spectral region, which wavelengths penetrate deeper in tis- peak power is 60 kW. Comparison of the reported laser sues and are much less harmful for living specimen than with a standard, 76 MHz Ti:sapphire oscillator regarding direct UV illumination in single-photon fluorescent mi- two-photon excitation efficiency in a laser scanning micro- croscopy. Photochemical damage mechanisms, which can scope shows that the 22 MHz laser generates the same flu- cause oxidative stress or direct DNA damage, only occur orescence signal at considerably, 1.82 times lower average in the focus of the objective lens, where multiphoton ab- power, which is expected to result in a reduced photothermal sorption takes place. -
Fibre Lasers – Conditioning Constructional and Technological
BULLETIN OF THE POLISH ACADEMY OF SCIENCES OPTOELECTRONICS TECHNICAL SCIENCES, Vol. 58, No. 4, 2010 DOI: 10.2478/v10175-010-0048-9 Fibre lasers – conditioning constructional and technological A. ZAJĄC1,2∗, D. DOROSZ2, M. KOCHANOWICZ2, M. SKÓRCZAKOWSKI1, and J. ŚWIDERSKI1 1, Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego St., 00-908 Warszawa, Poland 2 Faculty of Electrical Engineering, Bialystok University of Technology, 45d Wiejska St., 15-351 Białystok, Poland Abstract. In this paper the actual level of fiber lasers’ development is presented. There is also presented the analysis of technological and constructional conditions that limit energy parameters of those sources. Authors also show a construction and a technological work, conducted in Poland, which led to improving energy and exploit parameters of fiber lasers. Key words: fibre lasers, conditioning constructional, conditioning technological. 1. Introduction Typical, basically known the 1964’s configuration of a fiber laser set-up fulfils two basic conditions: an active cen- The year of 1960 was a breakthrough in the optical science – tre is a core of an optical fiber with addition of rare earth ions on 16th May the first laser was built. (it is likely to use a single-mode fiber but in many applica- The properties of laser beam – monochromatic, coherent tions also a multi-mode fiber is used), an active addition is and collimated beam – had not been possible to get in exist- optically stimulated – for lasers of medium and high power ing sources of optical radiation in visible spectrum until that it is effective in the configuration of lateral pumping (dis- moment. -
Imaging with Second-Harmonic Generation Nanoparticles
1 Imaging with Second-Harmonic Generation Nanoparticles Thesis by Chia-Lung Hsieh In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy California Institute of Technology Pasadena, California 2011 (Defended March 16, 2011) ii © 2011 Chia-Lung Hsieh All Rights Reserved iii Publications contained within this thesis: 1. C. L. Hsieh, R. Grange, Y. Pu, and D. Psaltis, "Three-dimensional harmonic holographic microcopy using nanoparticles as probes for cell imaging," Opt. Express 17, 2880–2891 (2009). 2. C. L. Hsieh, R. Grange, Y. Pu, and D. Psaltis, "Bioconjugation of barium titanate nanocrystals with immunoglobulin G antibody for second harmonic radiation imaging probes," Biomaterials 31, 2272–2277 (2010). 3. C. L. Hsieh, Y. Pu, R. Grange, and D. Psaltis, "Second harmonic generation from nanocrystals under linearly and circularly polarized excitations," Opt. Express 18, 11917–11932 (2010). 4. C. L. Hsieh, Y. Pu, R. Grange, and D. Psaltis, "Digital phase conjugation of second harmonic radiation emitted by nanoparticles in turbid media," Opt. Express 18, 12283–12290 (2010). 5. C. L. Hsieh, Y. Pu, R. Grange, G. Laporte, and D. Psaltis, "Imaging through turbid layers by scanning the phase conjugated second harmonic radiation from a nanoparticle," Opt. Express 18, 20723–20731 (2010). iv Acknowledgements During my five-year Ph.D. studies, I have thought a lot about science and life, but I have never thought of the moment of writing the acknowledgements of my thesis. At this moment, after finishing writing six chapters of my thesis, I realize the acknowledgment is probably one of the most difficult parts for me to complete. -
Contrast Enhancement for Topographic Imaging in Confocal Laser Scanning Microscopy
applied sciences Article Contrast Enhancement for Topographic Imaging in Confocal Laser Scanning Microscopy Lena Schnitzler *,†, Markus Finkeldey †, Martin R. Hofmann and Nils C. Gerhardt Photonics and Terahertz Technology, Ruhr University Bochum, 44780 Bochum, Germany * Correspondence: [email protected] † These authors contributed equally to this work. Received: 26 June 2019; Accepted: 29 July 2019; Published: 31 July 2019 Featured Application: The method for contrast enhancement presented in this work, can be used to increase the image contrast of topographic structures. It might be an essential tool for non-destructive testing in the quality management of microcontroller production, in the processing of semiconductors or in the developement and characterization of MEMs. Even structures with low height variance can be observed. Abstract: The influence of the axial pinhole position in a confocal microscope in terms of the contrast of the image is analyzed. The pinhole displacement method is introduced which allows to increase the contrast for topographic imaging. To demonstrate this approach, the simulated data of a confocal setup as well as experimental data is shown. The simulated data is verified experimentally by a custom stage scanning reflective microscopy setup using a semiconductor test target with low contrast structures of sizes between 200 nm and 500 nm. With the introduced technique, we are able to achieve a contrast enhancement of up to 80% without loosing diffraction limited resolution. We do not add additional components to the setup, thus our concept is applicable for all types of confocal microscopes. Furthermore, we show the application of the contrast enhancement in imaging integrated circuits. Keywords: microscopy; confocal microscopy; contrast enhancement 1. -
Optical Tweezers and Confocal Microscopy for Simultaneous Three-Dimensional Manipulation and Imaging in Concentrated Colloidal Dispersions Dirk L
REVIEW OF SCIENTIFIC INSTRUMENTS VOLUME 75, NUMBER 9 SEPTEMBER 2004 Optical tweezers and confocal microscopy for simultaneous three-dimensional manipulation and imaging in concentrated colloidal dispersions Dirk L. J. Vossena) and Astrid van der Horst FOM Institute for Atomic and Molecular Physics, Kruislaan 407, 1098 SJ Amsterdam, and Soft Condensed Matter, Debye Institute, Utrecht University, Princetonplein 5, 3584 CC Utrecht, The Netherlands Marileen Dogterom FOM Institute for Atomic and Molecular Physics, Kruislaan 407, 1098 SJ Amsterdam, The Netherlands Alfons van Blaaderenb) FOM Institute for Atomic and Molecular Physics, Kruislaan 407, 1098 SJ Amsterdam, and Soft Condensed Matter, Debye Institute, Utrecht University, Princetonplein 5, 3584 CC Utrecht, The Netherlands (Received 25 February 2004; accepted 10 June 2004; published 14 September 2004) A setup is described for simultaneous three-dimensional manipulation and imaging inside a concentrated colloidal dispersion using (time-shared) optical tweezers and confocal microscopy. The use of two microscope objectives, one above and one below the sample, enables imaging to be completely decoupled from trapping. The instrument can be used in different trapping (inverted, upright, and counterpropagating) and imaging modes. Optical tweezers arrays, dynamically changeable and capable of trapping several hundreds of micrometer-sized particles, were created using acousto-optic deflectors. Several schemes are demonstrated to trap three-dimensional colloidal structures with optical tweezers. One combined a Pockels cell and polarizing beam splitters to create two trapping planes at different depths in the sample, in which the optical traps could be manipulated independently. Optical tweezers were used to manipulate collections of particles inside concentrated colloidal dispersions, allowing control over colloidal crystallization and melting. -
Introduction to Confocal Laser Scanning Microscopy (LEICA)
Introduction to Confocal Laser Scanning Microscopy (LEICA) This presentation has been put together as a common effort of Urs Ziegler, Anne Greet Bittermann, Mathias Hoechli. Many pages are copied from Internet web pages or from presentations given by Leica, Zeiss and other companies. Please browse the internet to learn interactively all about optics. For questions & registration please contact www.zmb.unizh.ch . Confocal Laser Scanning Microscopy xy yz 100 µm xz 100 µm xy yz xz thick specimens at different depth 3D reconstruction Types of confocal microscopes { { { point confocal slit confocal spinning disc confocal (Nipkov) Best resolution and out-of-focus suppression as well as highest multispectral flexibility is achieved only by the classical single point confocal system ! Fundamental Set-up of Fluorescence Microscopes: confocal vs. widefield Confocal Widefield Fluorescence Fluorescence Microscopy Microscopy Photomultiplier LASER detector Detector pinhole aperture CCD Dichroic mirror Fluorescence Light Source Light source Okular pinhole aperture Fluorescence Filter Cube Objectives Sample Plane Z Focus Confocal laser scanning microscope - set up: The system is composed of a a regular florescence microscope and the confocal part, including scan head, laser optics, computer. Comparison: Widefield - Confocal Y X Higher z-resolution and reduced out-of-focus-blur make confocal pictures crisper and clearer. Only a small volume can be visualized by confocal microscopes at once. Bigger volumes need time consuming sampling and image reassembling.