extinguishers and trolley units ancilliary items brigade equipment detection and alarms The Gloria brand is recognised by the independent fire trade as a product of renowned quality.

Fully approved to relevant British and European standards with a proven track record of durability and reliability – the Gloria range offers customers true peace of mind.

With both stored pressure and cartridge operated extinguishers available, to 1 cover practically any type of fire risk, you needn’t waste time searching for a complete extinguisher range – you’ve just found it.

Items in this catalogue are available at the time of publication but we reserve the right to change our SECTION 1 product range and/or product specification anytime. Fire Power Extinguishers 2-8 Trolley Units 9-10

extinguishers 2-10 extinguishers and trolley units ancilliary items brigade equipment detection and alarms  Extinguishers

Water Extinguishers Stored Pressure/Cartridge Operated Section 1 4

Portable Fire Extinguishers Portable Fire All Water General n Easy squeeze grip operation n Fully refillable n Controlled discharge n Internal polyethylene lining n Wall mount bracket included n Strong protective base n Robust discharge hose n Jet nozzle

For Stored Pressure (Water additive only) n Weight and ease of use advantages n Effective spray application n Spray nozzle n Have passed the 35kv conductivity discharge test

SP SP CO SP Specifications Water Water Water Water Additive Additive Model: W9DN W3DX W6DX WI9DB Item number: 4903/207 4918/207 4919/207 4904/207 Capacity 9ltr 3ltr 6ltr 9ltr Fire rating 13A 13A 21A 13A Height (mm) 620 435 533 568 Cylinder diameter (mm) 200 160 180 183 Overall width (mm) 280 275 230 216 Filled weight (kg) 14.3 4.4 12.6 8 Range of throw (m) 7-8 4 4 4-6 Duration of discharge (secs) 60 30 60 45 Working pressure (bar) 7 7 7 14 Temperature range (°c) 0 to +60 +5 to +60 +5 to +60 0 to +60 BS EN3 approved Y Y Y Y Med approved Y Y Extinguishers 

Foam Extinguishers Stored Pressure/Cartridge Operated Section 1 4

All Foam General For Shrouded Head Foam (Below) Portable Fire Extinguishers Portable Fire n Easy squeeze grip operation n Unique push button operation n Fully refilable n Wire transport bracket and n Controlled discharge securing strap included n Internal polyethylene lining n Wall mount bracket included n Strong protective base* n Robust discharge hose n Spray nozzle n Have passed the 35kv conductivity discharge test

*Excludes 2ltr models

SP Foam Specifications SP SP SP SP CO CO (shrouded Foam Foam Foam Foam Foam Foam head) Model: SD2LW S3DLWB S6DLWB S9DLWB SI6DB SI9DB S2LW TypeItem number: AFFF AFFF 4260/207AFFF 4257/207AFFF 4251/207 4252/207 4253/207 4254/207 4256/207 Capacity Foam Foam 2ltrFoam Foam3ltr 6ltr 9ltr 6ltr 9ltr 2ltr Spray Spray Spray Spray Fire rating 5A 55B 8A 89B 13A 183B 21A 183B 13A 233B 21A 233B 5A 70B S/P S/P S/P S/P Height (mm) 365 485 455 610 610 623 365 Cylinder diameter (mm) 108 165 170 200 160 200 110 Overall width (mm) 145 270 260 260 270 285 152 Filled weight (kg) 3.5 5.9 10.5 14.9 7 8 3.5 Range of throw (m) 2.5 4 4-6 4-6 4-6 4-6 2 Duration of discharge (secs) 22 14 36 53 26 49 20 Working pressure (bar) 15 7 7 7 14 8 15 Temperature range (°c) 0 to +60 +5 to +60 0 to +60 0 to +60 0 to +60 0 to +60 0 to +60 BS EN3 approved Y Y Y Y Y Y Y Med approved Y Y Y  Extinguishers

Powder Extinguishers Stored Pressure/Cartridge Operated Section 1 4 Powder Extinguishers

All Powder General n Easy squeeze grip operation n Fully refillable n Controlled discharge n Multi-purpose application n 1 & 2kg C/W wire transport bracket and securing strap n 6,9 & 12kg C/W wall mounting bracket n Strong protective base* n Robust discharge hose (4,6,9 & 12kg)

*Excludes 1kg and 2kg models

SP SP SP SP SP SP Specifications Powder Powder Powder Powder Powder Powder

Model: PD1GA PD2G PD4GA PD6GA PD9GA PD12GA Item number: 4358/207 4352/207 4354/207 4356/207 4359/207 4366/207 Capacity 1kg 2kg 4kg 6kg 9kg 12kg Fire rating 5A 34B 13A 89B 21A 113B 27A 183B 43A 233B 55A 233B Height (mm) 280 408 415 505 605 590 Cylinder diameter (mm) 95 108 160 160 200 210 Overall width (mm) 135 170 310 285 305 265 Filled weight (kg) 1.5 3.2 6.7 9.1 13.6 17.3 Range of throw (m) 4 4 6 6 7 7 Duration of discharge (secs) 8 10 12 16 16 22 Working pressure (bar) 15 15 15 15 15 15 Temperature range (°c) -30 to +60 -30 to +60 -30 to +60 -30 to +60 -30 to +60 -30 to +60 BS EN3 approved Y Y Y Y Y Y Med approved Y** Y Y Y

**For Lifeboat use only Extinguishers 

Powder Extinguishers Stored Pressure/Cartridge Operated Section 1 4 Water Extinguishers Water

For Shrouded Head Powder Cartridge Operated Powder n Unique push button operation n Easy squeeze grip operation n Compact with easy operation n Fully refilable n Carrying handle n Controlled discharge n Integrated, protected, pressure gauge n Multi-purpose application n Fully refillable n Heavy duty brass head assembly n Controlled discharge n C/W wall mount bracket n C/W bracket and securing strap n Strong protective base n Robust discharge hose

SP Powder SP Powder CO CO Specifications (Shrouded Head) (Shrouded Head) Powder Powder

Model: P1GM P2GM PEP6GA PEP12GA Item number: 4351/207 4362/207 4360/207 4368/207 Capacity 1kg 2kg 6kg 12kg Fire rating 8A 34B 13A 89B 27A 144B 43A 233B Height (mm) 267 315 540 640 Cylinder diameter (mm) 90 110 160 200 Overall width (mm) 109 145 270 320 Filled weight (kg) 1.5 3.5 10.1 19 Range of throw (m) 4 4 6 7 Duration of discharge (secs) 8 10 14 21 Working pressure (bar) 15 15 Temperature range (°c) -30 to +60 -30 to +60 -20 to +60 -20 to +60 BS EN3 approved Y Y Y Y Med approved Y** Y** Y Y

**For Lifeboat use only  Extinguishers

CO2 Extinguishers Stored Pressure Section 1 4 co2 Extinguishers

n Easy squeeze grip operation n Fully refilable n Controlled discharge n Wall mount bracket included n C20GH offers 55B rating & safe to handle horn n Lightweight aluminium cylinder

SP SP SP Specifications CO2 CO2 CO2

Model: C20G C20GH C50G Item number: 4705/207 4706/207 4707/207 Capacity 2kg 2kg 5kg Fire rating 34B 55B 70B Height (mm) 490 490 750 Cylinder diameter (mm) 117 117 152 Overall width (mm) 180 180 310 Filled weight (kg) 4.93 4.93 11.59 Range of throw (m) 4 4 4 Duration of discharge (secs) 8 9 14 Working pressure (bar) 56 56 56 Temperature range (°c) -30 to +60 -30 to +60 -30 to +60 BS EN3 approved Y Y Y Med approved Y Extinguishers 

D-Class Powder Extinguishers F-Class Cartridge Operated Stored Pressure Section 1 4

n Easy squeeze grip operation n Easy squeeze grip operation n Fully refilable n Fully refilable D-Class & F-Class Extinguishers n Controlled discharge n Controlled discharge n Lance applicator n Lance applicator n Specifically designed for use on metal fires n Specifically designed for use on cooking oil fires n Wall mount bracket included n Solution reacts with oil to prevent re-ignition n Strong protective base n Wall mount bracket included

CO CO Specifications Powder D-Class F-Class

Model: P12M W6DRC Item number: 4367/207 4500/207 Capacity 12kg 6ltr Fire rating D 13A 75F Height (mm) 685 533 Cylinder diameter (mm) 218 180 Overall width (mm) 306 242 Filled weight (kg) 21 11.8 Range of throw (m) 7 4 Duration of discharge (secs) 20 43 Working pressure (bar) 15 7 Temperature range (°c) -20 to +60 0 to +60 BS EN3 approved Y Y Med approved  Extinguishers

Stainless Steel Extinguishers Polished Extinguisher Stored Pressure Stored Pressure Section 1 4 Extinguishers

n Ideal for environments where hygiene is paramount when considering architecture n Highly polished surface finish n Corrosion resistant construction n Simple “seize and squeeze” operation n Controllable discharge assures efficient use of content and minimises clean-up n All extinguishers are re-chargeable

SP SP SP SP SP Specifications Water Water Foam Foam CO2

Model: FPW6S FPW9S FPF6S FPF9S C20G Item number: 4905/207 4906/207 4217/207 4218/207 4705/06 Capacity 6ltr 9ltr 6ltr 9ltr 2kg Fire rating 13A 21A 13A 144B 21A 183B 34B Height (mm) 500 640 500 640 490 Cylinder diameter (mm) 180 180 180 180 117 Overall width (mm) 300 300 300 300 180 Filled weight (kg) 8.63 12.22 8.63 12.22 4.93 Range of throw (m) >4 >4 >4 >4 4 Duration of discharge (secs) 40 60 25 40 8 Working pressure (bar) 15 bar 15 bar 15 bar 15 bar 56 Temperature range (°c) 0 to 60 0 to 60 0 to 60 0 to 60 -30 to +60 BS EN3 approved Med approved Extinguishers 

Powder/Foam Trolley Units Stored Pressure/Catridge Operated Section 1 4 Trolley Extinguishers Trolley

n Mobile & stable n Weather-resistant polyester paint finish n Solid tyred steel wheels n Safety valve n Space-saving design n Easy to maintain n Controlled discharge n Single operator required n CE marked n Precision built mechanical pressure gauge for accurate pressure reading n High grade brass head ensures reliability & optimises efficiency

SP SP CO CO Specifications Powder Powder Powder Foam

Model: PD25 PD50 P50G LW50 Item number: UTR00008 UTR00009 UTR00007 / UTR00006 UTR00005 Capacity 25kg 50kg 50kg 50ltr Height (mm) 1004 1130 1070 595 Cylinder diameter (mm) 250 300 495 660 Overall width (mm) 380 450 615 103 Filled weight (kg) 45 82 100 12 Range of throw (m) 10-12 65 Duration of discharge (secs) 25 50 50 18 Working pressure (bar) 14 0 to +50 Temperature range (°c) -20 to +60 C/W 5m hose Available with 5 & 10m hose BS EN3 approved Med approved 10 Extinguishers

CO2 Trolley Units Stored Pressure Section 1 4 Trolley Extinguishers Trolley

n Approval to DIN EN 3 n Cylindrical snow horn for effective fire fighting n Mobile & stable n Controlled discharge n Additional handles on snow horn for optimal performance

SP SP SP SP Specifications CO2 CO2 CO2 CO2

Model: KS10 KS20 KS30 KS50 Item number: UTR00000 UTR00001 UTR0003 / UTR0002 UTR0004 Capacity 10kg 20kg 30kg 50kg Fire rating 113B 144B B 5 x 144B Height (mm) 1040 1210 1520 1590 Cylinder diameter (mm) 480 480 520 540 Overall width (mm) 480 480 1540 1100 Filled weight (kg) 45 72.4 110 150 Range of throw (m) 4-5 5.5 4-5 4-5 Duration of discharge (secs) 15 20 78 45 Working pressure (bar) 58 58 58 56 Temperature range (°c) -20 to +60 -20 to +60 -20 to +60 -20 to +60 C/W 6m hose C/W 6m hose Available with 6 & 10m hose C/W 6m hose BS EN3 approved Med approved Kitemar KM 506560k BS No. EN 81/023381869:1997

DISCAR Fo FIR r D us o no e D t on AFTE use cookin

D on R USE

o mor pan g no e oi 1

t us tha s containingl fires

e n 3 E o .

n pan litre

300m s s o 2

B exceedingf oil m x m 2 LANK diameter

Pul

an l tab 1

d s downwa . outwa 2

rds r E m Cove ds materia T r bu section 2 rning Fire Blankets 12 l completely Cabinets 12-13 Switc Covers 14 leav h of Stands 14 e coveref hea Fire Points 15 t and Panic Bolts, Key Box d unti and Latches 16-17 l cool Dorgard 1PUL7 Escape Ladders RELEAS17 L Alarm Bell 17 TAB Fire Buckets 18 E S Domestic Extinguishers 18 BLANKETO First Aid Kits 18 T

ancillary items 11-18 extinguishers and hose reels ancilliary items brigade equipment detection and alarms 12 ANCILLARY ITEMS

BLANKETS CABINETS Fire Blankets Hinged Door Cabinets Section 2 4

a b c

A range of top quality slim fire blankets. Suitable for A choice of single and double hinged cabinets made smothering and extinguishing fires in homes, kitchens, from tough new ABS and PE plastics. Traditional GRP schools, hospitals, laboratories, offices and factories. cabinets are also still available if preferred. Fire blankets offer a number of advantages over other ABS/Polyurethane Cabinets blankets commonly available: Fire Blankets and Cabinets Fire ■ Environmentally friendly – manufactured from recyclable or recycled materials. ■ 12 months warranty. ■ Consistent, smooth finish (internal and external). ■ 200 gram cloth ensures flexibility and drapability. ■ Will not chip or crack. ■ The suppleness and strength of the blanket. offers user confidence as it is well insulated, yet easily ■ Easily transportable. drapes over the fire. ■ Innovative design and manufacturing process. ■ Full traceability through individual blanket batch ■ Higher impact strength than GRP. numbering. ■ Hygienic – suitable for food preparation and ■ Flush end caps for easy cleaning. clinical environments (unlike GRP). ■ Hinged cap with security seal option to avoids ■ Suitable for wall or post mounting. blankets being tampered with. ■ Toggle clamp closure mechanism. ■ Production is made under a quality management system ISO 9001:2000 ensuring strict quality control GRP Cabinets procedures are met. ■ Specially designed base to give safe, ■ All blankets comply with BS EN 1869:1997 and are two-handed removal of extinguisher. kitemarked. ■ Polymide wing closure.

Description Part Number ■ Corrosion resistant construction. 1.0m x 1.0m slim pack – red 81/02332 ■ High-gloss finish. 1.2m x 1.2m slim pack – red 81/02338 ■ Suitable for wall or post mounting. 1.8m x 1.2m slim pack – red 81/02344

Ref Description Part Number A Single cabinet – ABS 81/00791 Double cabinet – ABS 81/00861 B Single cabinet – GRP 46/54653 Double cabinet – GRP 46/54654 C Single – Clear front 81/02811 C Double – Clear front 81/02812 All the above are not suitable for 5kg C02 Extinguishers A Single cabinet for 5kg CO2 Ext – ABS 81/02239 ■ ■ Cabinet Polyethylene polyethylene. from made cabinets extinguisher vehicle of choice A Cabinet VehicleExtinguisher 6kg Extinguisher – H650 xW240 x D240mm x xW240 H650 – Extinguisher 6kg D270mm x x H750 W300 – Extinguisher 9kg Fixingkit for vehicle cabinet horizontal– mounting Fixingkit for vehicle cabinet 30/60– degree angle mounting separately order please – kit fixing a include * not Thesedo for * cabinet Vehicleextinguisher for * cabinet Vehicleextinguisher Description

Incorporates 4 x M8 encapsulated T nuts. T encapsulated M8 x 4 Incorporates design. lightweight and Shatterproof

Part Number

81/00792 81/00870 81/02327 81/02053

■ ■ ■ ■ ■ Hose ■ ■

ose Cradle Hose Description Description Cover Rigid Reel Hose Hose Cradle Hose

Can be mounted in cabinets or to walls. to or cabinets in mounted be Can resin. glass-reinforcedpolyester red in Manufactured (fixings not supplied) not (fixings resin (GRP). resin H570mm x W600mm x D260mm. x W600mm x H570mm conditions. environmental harsh in use for Designed reel. hose to access easy Lift-off-frontfor supplied). not (fixings reels hose swinging rear-mountedand for fixed Suitable glass-reinforcedpolyester red in Manufactured Reel gid Cover Rgid a n c i lla

r y

i tem Part Number Part Number 81/00247 46/54225 s

Cabinets4Section 2 13 14 Covers & Stands4Section 2 H ExtinguisherCovers COVE ■ ■ ■ ■ ■ ■ ■ Redhose reel flexible cover Description Red24" x 11" extinguisher cover Red20" x 11" extinguisher cover Description ose

Designedfor rapid removal. Idealprotection in harsh environments. Manufacturedfrom strengthened PVC. Designedfor rapid removal Idealprotection in harsh environments. Clearviewing port. Manufacturedfrom PVC. R eelCover RS

A N C I

LLA

R

Y Y I TEM

Part Number S

PartNumber 46/57354 81/00108 81/00107 ■ ■ Aprestige range of stands. Extinguisher S Extinguisher Doublestand –grey Doublestand –red Singlestand –grey Singlestand –red Description Doublestand –red Singlestand –red Description

TA Singleand double versions. High-glossfinish. N D

S

S

tands-Moulded Plastic

S tands-G

R P

Part Number Part

Number 81/02408 81/02407 81/02406 81/02405 81/02744 81/02743

ANCILLARY ITEMS 15

Extinguisher Fire Points Mobile Fire Points Double / Triple Section 1 4 Fire Points Fire

■ Manufactured from plastic ABS. A choice of mobile fire points, ideal for moving firefighting ■ Will not chip or crack. equipment close to the source of a fire.

■ Higher impact strength than GRP. ■ Chassis fabricated from mild steel square tube. ■ Epoxy polyester powder paint finish in red. ■ Nylon wheels with rubber tread for ease of Description Part Number movement. Single fire point 46/57357 ■ Ideal for petrol station forecourts. Double fire point 46/57358

Description Part Number To hold two fire extinguishers and one fire bucket 81/00212 To hold three fire extinguishers and two fire buckets 46/57049 To hold two fire extinguishers, and a fire bucket, complete with bell 46/57815 16 ANCILLARY ITEMS

ESCAPE BOLTS, KEYS AND LATCHES Key Box and Glasses Redlam Panic Bolts Section 2 4 Escape & Fire S afety Escape & Fire Manufactured from cast aluminium, Redlam panic bolts ■ Manufactured from durable ABS plastic. are the economical solution to the problem of providing ■ Unique ‘snap fit’ design. reliable security for internal emergency exits. ■ Mk I key box supplied complete with printed glass. Mark I ■ Spare glass for Mk II key box can also be supplied. Designed for emergency exit single doors. Breaking the Ceramtube™ results in the bolt sliding back automatically and unlocking the door. Ref Description Part Number Mark II A Mk I key box 46/54280 Designed for interconnecting emergency exit doors. B Hammer and chain 39/51921 Operates on one side of the door by breaking the Spare glass for Mk I key box 46/27218 Ceramtube™ and on the other side of the door by Spare glass for Mk II key 46/57345 pushing the knob. Both versions are supplied complete with hammer and Panic Latch chain. Padlocks and ‘To open break tube’ signs are available separately. Use of an optional padlock prevents unauthorised removal of Ceramtube™ without breaking the tube itself.

Ceramtube™ Replacement cartridges for both Mk I and Mk II Redlam panic bolts. Designed to produce no sharp edges when smashed. Packed in boxes of twenty. Incorporates a robust rectangular section, steel cross arm with downward thrust action, giving added strength, ease of operation and an attractive appearance.

■ Manufactured primarily from Mazak Alloy to BS 1004A. ■ Finished in dark metallic grey. ■ Surface mounted. ■ Supplied with full fixing instructions. ■ Can be converted for right or left. Description Part Number hand operation. Mk I Panic bolt 46/32207 Mk II Panic bolt 46/32951 Keeper plate (spare) 46/33070 Hammer and chain (spare) 39/51921 Ceramtube™ (box of 20) 46/57050 Description Part Number Padlock (anti-tamper) 46/54457 Panic latch 46/57615 ANCILLARY ITEMS 17

Single and Double Door Panic Latch/Bolt Escape Ladders 15 and 25 feet Steel escape ladders, intended for domestic use only.

■ Suitable for two and three storey buildings. ■ Unique ‘tangle-free’ design. ■ Fully assembled. ■ Quickly attached to window for easy escape. Section 2 4 ■ White coating to prevent corrosion.

Description Part Number Escape ladder – 15 foot 46/6355 ■ Conforms to BS 5725 part 1. Escape ladder – 25 foot 46/6430 ■ Specified and approved by fire officers and local authorities. Rotary Hand Alarm Bell ■ Anti-thrust device prevents upward leverage of the bottom shoot, providing increased security.

■ Triple action device fitted to the top shoot keeps the S afety Escape & Fire shoots withdrawn when the door is open and auto- matically releases them when the door is closed. ■ Surface mounted – fixing instructions supplied. ■ Manufactured from cast iron with steel tubes, brass follower and extruded aluminium guides. ■ Finished in dark metallic grey.

Description Part Number Single door panic latch/bolt 46/60145 Double door panic latch/bolt 46/61564

Acoustic Fire Door Release Device

■ Ideal for outside locations such as caravan sites ■ Bell sounds 60dB alarm up to 35 metres ■ Die-cast aluminium dome, powder coated red ■ Base plate die-cast aluminium ■ Pre-drilled flange for fast and easy mounting (fixings not included) ■ Weight 1.8 kg, overall diameter 280mm, depth 135mm Dorgard is an acoustically activated fire door release device. Dorgard can hold fire doors open in any Description Part Number position and release them automatically should a fire Rotary Hand Alarm Bell 42/57030 alarm sound.

■ Manufactured and tested in accordance with BS EN 1155. ■ Accepted by Chief Fire Officers Association (CFOA). ■ Endorsed by the National Care Homes Association. ■ Designed in line with the Disability Discrimination Act.

Description Part Number Dorgard Auto release - black 81/02781 Other colours available on request, subject to lead times. 18 ANCILLARY PRODUCTS

Fire Buckets Home/Car Guard Extinguishers Metal and Plastic Stored Pressure Multi-Purpose Section 2 4 S afety Products

■ Suitable for garage forecourt protection and ■ Ideal for the home, car, boat, caravan or garage. clearing up spillages. ■ Now comes complete with wire bracket. ■ Metal buckets are epoxy polyester powder ■ Safe for most household fire types including painted in red. electrical fires (not suitable for cooking fat fires). ■ ‘Fire’ label supplied loose with metal bucket. ■ High grade nickel plated brass valve assembly ■ Lids for both buckets are supplied separately. ensures reliability and optimizes efficiency whilst ■ Wall-mounting bracket suitable for metal and being protected from corrosion. plastic buckets. ■ Coated steel levers built to withstand the hardest knocks. Ref Description Part Number ■ 14 bar working pressure for maximum fire fighting A Metal flat bottom 3745/00 performance gives greater application reach B Metal lid for 3745/00 3747/00 ensuring user safety. C Plastic 2 gallon 'D' type 3745/01 ■ Long drawn high grade steel body shell for D Plastic lid for 3745/01 3747/01 optimum strength. E Wall mounting bracket 3749/00 ■ Polyester external coating adds extra protection First Aid Kits to withstand extreme temperatures, dirty environments and UV degradation. ■ Precision built mechanical pressure gauge provides a very accurate indication of extinguisher’s pressure status. ■ Approved to the Pressure Equipment Directive. ■ CE marked and kitemarked.

Type Powder Powder 1kg 2kg Fire rating 8A 34B 13A 70B Height (mm) 335 385 A comprehensive range of first aid kits that are fully Cylinder dia (mm) 78 112 compliant with the Approved Code of Practice and Overall width (mm) 118 132 the Health and Safety Executive. Filled weight (kg) 2.0 3.42 Range of throw (m) >2 >2 Duration of discharge (secs) min 6 min 9 Description Part Number Working pressure (at 20˚C) 14 bar 14 bar 1 to 10 persons 81/02807 Temperature range (˚C) -20 to +60 -20 to +60 1 to 20 persons 81/02808 BS EN3 approved ✓ ✓ 1 to 50 persons 81/02809 Part number 81/02652 81/02694 3

SEction 3

Inlet Breechings 20 Inlet and Outlet Cabinets 21 Outlet Valves 21 Valve Ancillaries 22 Standpipes/Bars/Keys 22 Underground Hydrants 23 Blank Plugs 23 Dividing Breeching 23 Hoses and Couplings 24 Branchpipes and Nozzles 25 Reelfoam Units 25 Foam 26

brigade equipment 19-26 extinguishers and hose reels ancilliary items brigade equipment detection and alarms 20 BRIGADE EQUIPMENT

Dry Rising Mains Installation Inlet Breechings

Dry and wet rising mains are intended for use by the fire brigade or other trained personnel. They provide a readily available means of delivering considerable quantities of water to extinguish or to prevent the spread of fire.

Section 3 Dry risers are vertical mains fitted into staircase enclosures or other suitable positions, with outlet valves on each 4 floor and inlets fitted at ground level to enable the fire brigade to connect to the water supply.

Wet risers are pipes kept permanently charged with water either from a storage tank (via a booster pump) or direct from the town’s main water supply.

Before installing dry or wet rising mains the exact requirements of the local fire brigade must be ascertained.

Complies with BS 5041 Part 3 Air Release Valve

Landing Valve Dry riser inlet breechings are normally fitted in glass-front- ed cabinets on the outside walls of buildings and have either two or four inlet connections.

They are used to feed water into the rising main through 1 2 ⁄2" fire hoses. A 100mm (4") rising main uses a two-way inlet breeching and a 150mm (6") main uses a four-way inlet breeching.

Drain Valves to BS 5154 Dry R iser Mains I nstallation/ nlet Breechings Normally fitted to inlet breechings but can be supplied Landing Valve separately.

Two-way Inlet Breechings External Wall 4" BSTD, 4" BSP parallel female or 100mm NP16 – can be mounted either horizontally or vertically.

Air Release Valve - See page 22

Description Part Number Inlet breeching two way flanged 4” BSTD (4 Holes) 46/54189 Steel Gate Valve Cabinet Inlet breeching two way flanged 100mm (8 Holes) 46/54903 with Glazed Door Inlet breeching two way screwed 4” BSP female 46/54194 Landing Valve Drain valve 46/57363 Blank cap and chain (drain valve) 46/57364 Rubber cap female 46/57365 Two-way Inlet Breaching

25mm Drain Ground Valve Floor BRIGADE EQUIPMENT 21

Inlet and Outlet Cabinets Outlet Valves Section 3 4

A range of inlet and outlet cabinets built to comply Landing Valves with BS5041: Part 5. Landing valves used on dry rising mains should normally be of the gate valve type, but globe pattern valves are occasionally n Designed to house inlet breechings and used. They act as outlets from the rising main and are fitted in Outlet Equipment landing valves. easily accessible positions on each floor above the first floor of a n Georgian wired glass panel and spring cylinder building and sometimes in deep basement areas. lock with key. Dry Riser Gate Valves n Manufactured from zintec, epoxy polyester 1 With 2 ⁄2" instantaneous female outlet to BS 336, blank cap powder coated in red. and chain, strap and padlock. Dry riser gate valves comply with the requirements of BS 5041:Part 2. Valves can be mounted in Cabinet sizes boxes complying with BS 5041:Part 4. Type of cabinet Width (mm) Length (mm) Depth (mm) 1 Two way vertical inlet 395 595 295 n Inlet flanged 2 ⁄2" BSP or 3" BS Table D or 65mm BS Two way horizontal inlet 595 395 295 4504 Table 16/21. 1 Outlet 463 612 325 n Inlet screwed 2 ⁄2" BSP.

NB: Please measure size of aperture before ordering. Globe Pattern Landing Valves (LP) These screw-down stop valves are primarily used as hydrant outlets on wet rising mains, but are occasionally used on dry Description Part Number risers under special circumstances and after discussion with the Two way inlet vertical dry riser cabinet 43/01035 fire brigade. Two way inlet horizontal dry riser cabinet 43/01036 n Gunmetal bodies, major working parts in Dry riser outlet cabinet 43/01034 manganese bronze. Spare glass for vertical dry riser inlet cabinet – H435mm x W190mm 43/01037 Spare glass for horizontal dry riser inlet cabinet – n Comply with the requirements of BS 504:Part 1 H235mm x W375mm 43/01038 and BS 5154. 1 Spare glass for dry riser outlet cabinet – H475mm x W190mm 46/63274 n Outlets are 2 ⁄2" instantaneous female to BS 336 and Spare glass for vertical dry riser inlet cabinet – H430mm x W185mm 81/02349 inlets flanged or screwed as required. Spare glass for horizontal dry riser inlet cabinet – n Accessories include blank caps and chain, straps H239mm x W344mm 81/02350 and padlocks. Spare glass for dry riser outlet cabinet – H435mm x W282mm 81/02351 Horizontal/Oblique Ref Description Part Number

1 A Flanged 2 ⁄ 2" BSTD horizontal 46/54101 A Flanged 65mm/ 3"BSTD horizontal 46/54897

1 A 2 ⁄ 2" BSP female inlet horizontal 46/54923

1 A 2 ⁄ 2" BSTD horizontal 46/54088 A 65mm / 3" BSTD horizontal 46/54898

1 B 2 ⁄ 2" BSTD oblique 46/54090 B 65mm / 3" BSTD oblique 46/54902

Bib Nose/Right Angle Ref Description Part Number

1 C 2 ⁄ 2" BSTD bib nose 46/54516

1 D 2 ⁄ 2" BSTD right angle 46/54089 22 BRIGADE EQUIPMENT

Valve Ancillaries Standpipes/Bars/Keys Section 3 4

The anti-tamper leather strap is for use with globe valves Standpipes, keys and bars are used to obtain water from and can be fastened using the 3⁄4" brass padlock. Other a pressurised mains supply via underground hydrants. The accessories include a replacement washer and an air standard outlet for underground valves according to BS 1 release valve for use at the top of a hydrant system. 750 is 2 ⁄2" BSRT male.

1 Air Release Valves Standpipes have as standard a 2 ⁄2" BSRT female inlet, Brigade Equipment • General Air valves are fitted at the top of a riser to release air which is compatible with our underground hydrants. when the riser is charged with water or to admit air when Standpipes are supplied either with single or double head draining off. outlets. Outlets are 2" female instantaneous with single twist release (BS 336). The double-head type is supplied n Screwed 1" BSP male. with one blank plug as standard. Contractors’ standpipes are supplied with a brass double check valve as standard. Ref Description Part Number 3 A Padlock brass ⁄4" 46/54458 1 3 B Leather strap ⁄2" x 13 ⁄4" 46/54456 Technical Specification 1 B Leather strap ⁄2" x 22" 46/54944 Standpipe double head, overall length to centre circle of head (A) 839mm C Air release valve 1" BSP 46/54175 1 D Washer 2 ⁄2" instantaneous 46/54470 Standpipe single head, overall length to centre circle of head (B) 839mm

Contractors’ standpipe with double check valve, single and double top

– overall length (to centre of horizontal pipework) 970mm

Hydrant key length (Part number 46/54177) 1042mm

Hydrant bar key length (Part number 46/54177) 1042mm

Hydrant bar length (Part number 46/54178) 915mm

Hydrant key length (Part number 46/54178) 762mm

Ref Description Part Number A Standpipe double head alloy 46/54958 1 2 ⁄2" BSRT female 46/54456 B Standpipe single head alloy 46/32575 1 2 ⁄2" BSRT female 46/54175 C Contractors stand pipe single 46/54470 C/W double check valve D Hydrant bar and key alloy 46/54177 D Hydrant bar and key mild steel 46/54178 Standpipe base washer 46/57366 BRIGADE EQUIPMENT 23

Underground Hydrants Blank Plugs Section 3 4

BS 750 Type II Hydrant Blank plugs are used to seal off water supplies and pre- Screw-down type, cast iron body with manganese vent dirt entering the valves or connectors. Blank plugs 1 bronze valve and forged bronze spindle. Supplied with are 2 ⁄2" instantaneous male type. blank cap, chain and frost valve. Gunmetal and aluminium blank plugs are pressure resist- ant; plastic and rubber blank caps act as dust Type 2: cover only. Brigade Equipment • General Inlet flange 3" BS Table ‘E’ or 80mm NP16 Ref Description Part Number 1 Outlet connection 2 ⁄2" BS Round Thread Male A Male alloy – 21⁄2" instantaneous 46/54322 Body Test Pressure 24 Bar B Male gunmetal – 21⁄2" instantaneous 46/54330 C Male rubber – 21⁄2" instantaneous 46/54324 Seat and Valve tested to 16 Bar D Male plastic – 21⁄2" instantaneous 46/54325 Weight 23kg

Dividing Breeching Ref Description Part Number A Underground hydrant type 2 46/57368 B Plastic blank cap 46/57382

1 Unvalved inlet end 2 ⁄2" male instantaneous and two 1 outlet ends each 2 ⁄2" female instantaneous with single twist release.

Description Part Number Aluminium alloy (unvalved) – 21⁄2"instantaneous 46/57821 24 BRIGADE EQUIPMENT

Hose and Couplings Instantaneous Couplings to BS 336 Section 3 4 H ose & Couplings

A selection of hose and couplings assemblies are listed below.

Description Part Number 18.3m x 45mm type 2 C/W light alloy couplings 46/57391 18.3m x 64mm type 2 C/W light alloy couplings 46/57377 A range of instantaneous couplings, used for connecting 23.0m x 64mm type 2 C/W light alloy couplings 46/54914 the water hose to the water supply quickly. The instan- 18.3m x 64mm type 1 C/W light alloy couplings 46/57379 taneous system is designated by BS 336 and is standard 23.0m x 64mm type 1 C/W light alloy couplings 46/57002 with British fire services for delivery applications. The predominant size is 64mm, the only size recognised by BS 336. The couplings incorporate a double pull Layflat Hose to BS 6391:1983 release and double ribbed (DR) hose tail. The hose is pushed over the tails and secured by wire or clips. Metric Conversion Table Feet Metres Inches Millimetres Technical Specification 60’ 18.3m 1.75" 45mm Mechanism Double pull release 75’ 23.0m 2.5" 64mm Hose connection Ribbed tails Male – overall length 114mm Female – overall length 120mm Type 1 and Type 2 Layflat Hose General-purpose synthetic delivery hose. Suitable for industrial and rural fire brigades as well as static building Ref Description Part Number protection. For marine use and for general industrial, commercial and civil engineering applications (including A 21⁄2” x 21⁄2” (64mm x 64mm) tail light alloy 46/32200 water authority applications) where a high-burst B 21⁄2” x 21⁄2” (64mm x 64mm) tail gunmetal 46/32190 performance hose is not necessary. C 21⁄2” x 21⁄2” (64mm x 64mm) tail plastic 46/34215 Washer 21⁄2” instantaneous 46/54470 n Lightweight and flexible. n Heat and cold resistant. n Anti-rot and anti-twist. n Type 2 version has a dirt-repellent, external elastomeric coating.

Technical Specification – Type 1 and Type 2

Weight Working pressure Burst pressure Size (gr/m) (bar) (bar)

13⁄4" (45mm) 200/230 12 49 2" (51mm) 230 10 39

21⁄2" (64mm) 280 10 39 BRIGADE EQUIPMENT 25

Branchpipes and Nozzles Reelfoam Units

Branchpipes provide an adjustable nozzle for altering the curtain of water from a narrow spray to a wide spray. Nozzles provide a fixed jet of water.

The basic branchpipe according to BS 336 has an 1 2 ⁄2" inlet male instantaneous and outlet threaded 1

1 ⁄3" BSP male for either a plain jet or a branchpipe Section 3 adjustable nozzle. 4

The branchpipe is controlled from ‘shut off’ through ‘jet’ and ‘spray’ to wide-angle ‘curtain’ by rotating the annular sleeve.

Dimensions Nozzle – length 120mm Branchpipe – overall length 178mm Instantaneous adaptor – overall length 112mm

n Designed to connect to a manual water fire hose reel. n Controllable discharge. n Operates with 12 litres of alcohol resistant foam concentrate (not supplied – see page 70). n Provides a firefighting capacity greater than the traditional 135 litre foam engine. Branchpipes, N ozzles & R eelfoam Units Description Part Number Low expansion unit with 19mm alloy couplings 46/57431 Chrome nozzle – alloy fittings 46/33141

Ref Description Part Number Price 1 A 2 ⁄2" Instantaneous integral gunmetal 46/54146 1 B 2 ⁄2" Instantaneous integral diffuser alloy 46/54393 1 1 C 2 ⁄2" Instantaneous male x ⁄2" Jet Blue ABS 46/54396 26 BRIGADE EQUIPMENT

Reddaway Foam Foam Section 3 4 Foam

3% and 6% AFFF Profoam 806 – Protein Foam – Not suitable for A synthetic aqueous film forming foam concentrate extinguishers for extinguishing and securing flammable hydrocarbon A premixable, low-expansion foam. Suitable for all liquid fires. Storex Reddaway AFFF is a unique types of nozzles, inductors, foam chambers and combination of hydrocarbon and fluorochemical surface discharge units. active agents. Centrifoam 906 – Film Forming Protein – Not AR – AFFF (3% – 6%) - Not suitable for suitable for extinguishers extinguishers A low-expansion foam that forms a vapour seal over A synthetic alcohol resistant aqueous film forming foam hydrocarbon fuel. concentrate for extinguishing and securing flammable hydrocarbon and polar solvent liquid fires. A polymer Filmfoam 916 – AFFF additive protects the foam blanket from the destructive A low-expansion foam suitable for hydrocarbon fuel. action of polar solvents. It is used in high-risk situations where hydrocarbons and polar solvents are stored, Filmfoam A836 – AFFF processed, or transported. It is ideal for industrial and An alcohol resistant foam, suitable for polar solvent and municipal fire departments. Typical applications include hydrocarbon fuels. bulk storage tanks, process areas, loading racks, marine terminals, military bases and airports. Ref Description Part Number A Profoam 806 Protein Foam 6% – 25ltr drum 46/24224 3% FP - Not suitable for extinguishers Centrifoam 906 FFFP 6% – 25ltr drum 46/57661 A fluoroprotein firefighting foam concentrate for B Filmfoam 916 AFFF 6% – 25ltr drum 46/57664 extinguishing and securing flammable hydrocarbon Filmfoam A836 AFFF alcohol resistant – 25ltr drum 46/57668 liquid fires. A protein base material provides a tough cohesive foam blanket with high resistance to heat that quickly smothers, cools and seals the fire risk. Fluorochemical surface active agents combined with the protein base increase the fluidity and fuel repellency of the foam.

Ref Description Part Number A AFFF Reddaway 6% – 25ltr drum 46/63237 B AFFF Reddaway 3% – 25ltr drum 46/63238 AR AFFF Reddaway 3% – 6% – 25ltr drum 46/63239 FP Storex Reddaway 3% – 25ltr drum 46/63241 4

SECTION 4 Conventional Detection Devices 28 Addressable Analogue Detection Devices 30-31 Manual Call Points & Sounders 1 Bells Sounders & Strobes 2 Door Holders 33 Sealed Lead Acid Batteries  Smoke/Heat Alarms 35 BS5839 Part 6 Grade C System/ CO Alarms 36 Emergency Lighting 37 Conventional Call System/ Test Equipment 38

detection & alarms 27-38 extinguishers and hose reels ancilliary items brigade equipment detection and alarms 28 DETECTION & ALARMS

Conventional Detection Devices

Apollo Range Apollo Accessories Complying to EN54 Pts 5/7/8 and LPC certificated. Section 4 4

The series 65 range of conventional detection devices A range of bases to complement series 65 devices and Fire Control & Detection Equipment Control Fire offer a complete answer to all your requirements. They to offer many alternative options. are compatible with any conventional control panel.

Ionisation Series 65 Mounting Bases Description Code Number Description Code Number Ionisation Smoke Detector Series 65 82/00399 (a) Mounting base standard series 60/65 82/00046 (d) Mounting base with line diode series 60/65 82/00050 Optical Smoke Detector Series 65 Description Code Number Technical Specification Optical Smoke Detector Series 65 82/00400 (b) Apollo

Heat Detectors Relay base max switching contact 50 volts Description Code Number CR (84-100C) Series 65 82/00401 Heat Detector A1R (54-65C) Series 65 82/00402 (c)

Technical Specification Ion Opt Heat Comb Voltage 24 DC 24V DC 24V DC 24V DC Quiescent current 45µA 45µA 53µA Alarm current 52mA 52mA 52mA 52mA DETECTION & ALARMS 29

Conventional Detection Devices

Hochiki Range Hochiki Accessories Section 4 4

The CDX range is a well established range of Mounting Bases (Conventional) conventional devices with an outstanding performance A range of bases to complement the CDX range of & Detection Equipment Control Fire record. Hochiki's flat response technology enables the devices offering many alternative options. photoelectronic device to be equally sensitive to a much wider range of combustible materials. Description Code Number Electronic free mounting base CDX Range 82/00047 (b) Ionisation Beam Detector Schottky line continuity base (Safeline) with remote indicator 82/00049 Description Code Number Remote indicator output CDX Range 82/00051 Ionisation Smoke Detector CDX Range 82/00037 (a)

Photoelectric Smoke Detector Description Code Number Photoelectric Smoke Detector CDX Range 82/00040 (b)

Heat Detectors Description Code Number Fixed Temperature (90C) CDX Range 82/00045 Rate of rise Grade 1 (60C) CDX Range 82/00042 (c) Combined Heat Grade 2 (60C) CDX Range 82/00043

Technical Specification - For all devices Operating voltage 15 - 30V DC Quiescent current 35µA Alarm current 40mA For all devices

The Hochiki beam detector is tested to BS5839 Pt5 and is LPCB approved. Direct wall mounting ensures virtually no vibration when in use.

Photoelectric Beam Detector Description Code Number Two Wire Beam Detector CDX Range 82/00290 30 DETECTION & ALARMS

Addressable Analogue Detection Devices

Hochiki Accessories Apollo Range KAC Manual Call Points Section 4 4

Manual Call Points (Conventional) KAC Manual callpoints - the major producer of call points offering surface and flush options with accessories - all to EN54 Pt2 and LPC certificated

Description Code Number Apollo XP95 Analogue Devices EN54 MCP for indoor use 82/00404 All devices are moulded in self extinguishing white Transparent hinged cover 82/00406 Fire Control & Detection Equipment Control Fire polycarbonate material and are set to EN54 thresholds. Replacement glass 82/00405 Spare test key 82/00407 Description Code Number Pattress box 82/00062 XP95 Ionisation smoke device 82/00095 (a) XP95 Optical smoke device 82/00097 (b) Class 2000 spares XP95 Multi sensor device 82/00103 (c) Description Code Number XP95 Temperature (STD) device 82/00100 (d) Transparent hinged cover 82/00056 XP95 High temp device 82/00101 Replacement glass 82/00058 XP95 Loop powered beam detector 82/00289 Spare test key 82/00060 XP95 Beam detector reflector 82/00291 Pattress box 82/00062 Technical Specification Ion Opt Heat Multi Supply voltage V DC 17 - 28 17 - 28 17 - 28 14 - 28 Modulation voltage V DC 5 - 9 5 - 9 5 - 9 5 - 9 Quiescent current 280µA 340µA 250µA 500µA Alarm current 2mA 4mA 2mA 3.5mA

Apollo Accessories Apollo Bases & Accessories XP95 Range Description Code Number Common base device and expert card 82/00104 Isolating base (20 devices) 82/00108 Isolator base 82/00110 Low power relay base 82/00091 Blank expert card 82/00112 Apollo Test Set 82/00133 DETECTION & ALARMS 31

Addressable Analogue Manual Call Points and Sounders Hochiki Range Apollo XP95 Section 4 4

Manual Call Points (Addressable) The XP95 range of manual call points uses the KAC world series call point It is available in three types. Approved to BS5839 Pt 2. Hochiki ASX Analogue Devices This range is designed to meet European approvals Description Code Number EN54 Pt5, Pt 7 and Pt 9 set to EN54 thresholds. Weather Proof Manual Call Point Series XP95 82/00127 (a)

Surface Manual Call point for Series XP95 82/00125 & Detection Equipment Control Fire Description Code Number Flush Manual Call point for Series XP95 82/00128 ASX Optical smoke device 82/00098 (a) ASX Ionisation smoke device 82/00096 (b) ASX Heat device R/R 82/00099 (c) Technical Specification - Apollo ASX Multi sensor device 82/000102 (d) Operating voltage 17 - 28V DC Communication protocol 5 - 9V Quiescent current 350µA Technical Specification Alarm current 2mA Ion Opt Heat Multi Supply voltage V DC 24 24 24 24 Apollo Standby current Apollo Sounders Low 140µA 120µA 90µA 120µA Description Code Number Normal 350µA 310µA 350µA 450µA 90dB sounder low profile loop powered sounder 82/00131 Devices per loop 127 127 127 127 100dB loop sounder 82/00129

Technical Specification - Apollo

Hochiki Accessories Low profile sounder Hochiki Bases & Accessories ASX Range Sound output 85dB (A) @ 1 metre Description Code Number Current consumption 3mA Common base 82/00105 100dB sounder Addressable base 82/00106 Operating voltage 14 - 28V DC polarity sensitive Master addressable base 82/00107 Quiescent current 1.1mA Isolator module 82/00114 Alarm current 4.5mA Mini zone monitoring module 82/00115 IP42 Zone monitor 82/00116 Relay output module 82/00118 Dual switch monitor 82/00119 Hand held programmer 82/00124 32 DETECTION & ALARMS

Bells, Sounders, Strobes for any System Fulleon Section 4 4

Fulleon Bells Singe Voice Fire Cryer Enhanced Sounder Fire Control Accessories Control Fire Description Code Number Description Code Number 6” Motorised bell 24 volt 82/00064 (a) Singe message non-sync. Voice enhanced sounder 82/00074 (d) Alternative messages available

Roshni Low Profile Banshee Sounder Description Code Number Description Code Number Roshni low profile, shallow base, 24 volt 82/00070 (b) Banshee LP.LF.Red 82/00071

Standard Squashni Sounder Kobishi Strobe Description Code Number Description Code Number Standard Squashni sounder. Tone 3. White 82/00069 Strobe light with interchangeable red lens 82/00075 (e) Standard Squashni sounder cover. White 82/00068 (c) Technical Specification Technical Specification Fire Cryer Kobishi Strobe Bells 6” 8” Supply voltage 18 - 30V DC 18 - 30V DC Alarm current 20mA Supply voltage 24V DC Alarm current 25mA 28mA Supply voltage 24V DC Alarm current 35mA Output 93/95dB (A) 95/97dB (A) Flash rate 60 - 100 @ 1 metre @ 1 metre Roshni Squashni Supply voltage 9 - 28V DC Supply voltage 10 - 28V DC Alarm current 16mA Alarm current 18mA Output @ 1 mtr 102dB (A) Output @ 1 mtr 93dB (A) DETECTION & ALARMS 33

Door Holders for any System

Fulleon Vimpex Section 4 4

Fulleon door holders designed to hold open fire or Vimpex door holders are IP54 rated and comply with smoke stop doors. BS 5839 Pt3 and EN 1155. A special feature is a spring Fire Control Accessories Control Fire In the event of an emergency they will release the door. loaded device to eliminate residual magnetism. A A manual release button is standard for both models. manual release button is standard for both models.

Door Holders & Accessories Door Holders & Accessories Description Code Number Description Code Number Wall mounted magnet door release 230 volt 82/00082 (a) Surface door retainer with back box 24 volt 82/00081 (c) Wall mounted magnet door release 24 volt 82/00080 Surface door retainer with back box 230 volt 82/00083 Floor mounted bracket for above 82/00085 Floor mounted bracket for above 82/00084

Technical Specification - Fulleon Technical Specification - Vimpex Power supply 24V DC or 230V AC Power supply 24V DC or 230V AC Holding current 50mA or 2VA Holding current 25mA or 1.5VA Kilogram force 40kg Kilogram force 20kg 34 DETECTION & ALARMS

Sealed Lead Acid Batteries

The NP range is highly respected and offers the following features. n Deep discharge recovery n Security from electrolyte leakage Section 4 n 4 Oxygen recombining n Float or cyclic use n Usable in any orientation n Lead calcium grids giving long life

Description Code Number 1.2AH 12 volt SLA Battery 82/00192 2.1AH 12 volt SLA Battery 82/00193 2.8AH 12 volt SLA Battery 82/00194 7.0AH 12 volt SLA Battery 82/00195 12.0AH 12 volt SLA Battery 82/00196 24.0AH 12 volt SLA Battery 82/00197 Fire Control Accessories Control Fire

A guide to SLA Battery back up capacity

The capacity of SLA batteries fitted to the Control and Example

Indicating Equipment is determined by the type of Product Standby Total Standby Alarm Total Alarm system installed (L or P) and is specified in BS 5839 Part Panel x 1 35mA 35mA 100mA 100mA 1 1988, section 16.5 Duration of the standby supply the Ionisation x 10 45µA 450µA 52mA 520mA Optical x 5 45µA 225µA 52mA 260mA following is a simple guide to calculate the capacity. Heat x 2 53µA 106µA 52mA 104mA MCP x 4 0 0 50mA 200mA Sounders x 6 0 0 16mA 96mA

1. Establish the total standby current drawn by all Total 35.143mA 35.781mA 332mA 1.280 A devices connected to and including the Control and Indicating Equipment. Add all the current readings together. Don’t forget to pay attention to the decimal The system has to meet the requirements for an L type places. i.e. mA 10-3, µA 10-6, etc. environment, (life safety) and is supervised at intervals of not more than 12 hours. 2. Establish the total alarm current drawn by all devises connected to and including the Control and Indicating Total standby current multiplied by 24 hours = 35.781mA x 24 = 0.858744 Ah. Equipment. Add all the current readings together. Don’t Total alarm current multiplied by 30 min. = 1.280A x 0.5 = 0.64 Ah. forget to pay attention to the decimal places. i.e. mA Add the standby Ah and the Alarm Ah = 0.858744 + 0.64 = 1.498744 Ah 10-3, µA 10-6, etc. Add 20% margin for charging. = 1.8 Ah. It is common practice to choose the nearest available size moving up a size if 3. Multiply the standby current by the number of hours necessary. So in this case the next available size will be 2.2 Ah. standby required.

4. As all the L and P systems require an alarm period of 30 minutes (except in very special cases, see standard) total alarm current should be multiplied by 0.5 (half of one hour)

5. Add the results of 3 and 4 together

6. BS 5839 Part 1 specifies that the batteries are able to provide its designed standby duration after 24 hours charge from it’s discharge state. To allow for this the capacity of the battery should be increased by 20% to overcome problems with charge rates. DETECTION & ALARMS 35

Smoke/Heat Alarms

BRK Kidde Section 4 4

All products are kite marked to BS5446 Pt 1 and C.E. approved except heat alarms which are tested EN54 Pt 5 sensitivity and BS5446 Pt 1 environmental

9 Volt DC Units Description Code Number & Gas Alarms Fire BS5446 Pt1 1990 Smoke Alarms IONISATION Description Code Number Basic Product 82/00203 (a) IONISATION 230 volt - 10 year lithium secondary supply with BRK silence and interconnect 82/00138 (a) OPTICAL 230 volt - 10 year lithium secondary supply with silence and interconnect 82/00398 (b) HEAT 230 volt - 10 year lithium secondary supply and interconnect 82/00140 (c)

9 Volt DC Units Description Code Number IONISATION ALARM Ionisation smoke alarm 82/00205 (b) OPTICAL alarm Optical smoke alarm interconnectable with Smoke & Heat Alarm Accessories alkaline battery 82/00212 (c) Description Code Number 230 Volt/9v DC AC/DC Unit Common base (Smoke Alarm) 82/00218 (d) Description Code Number Common base (Heat Alarm) 82/00206 IONISATION AC/DC + Alkaline + Interconnect 82/00210 (d) OPTICAL AC/DC + Alkaline + Interconnect 82/00214 (e)

Accessories Description Code Number Common Base (Smoke Alarm) 82/00218 36 DETECTION & ALARMS

Fire Alarms CO Alarms

BRK Kidde Sensors Section 4 4 Fire & Gas Alarms Fire

Flexi-Point - BS5839 Pt6 Grade C n 230V AC Supply n 20 devices can be wired in CO Alarms Description Code Number n Built in call point (BS5839 Pt2) 9CO-5 4.5v DC Carbon Monoxide Alarm - Basic 82/00223 n Built in sounder 900-0146 4.5v DC Carbon Monoxide Alarm - Digital Display 82/00421 n 10 year lithium secondary supply 9V DC n Enabling key switch

Slave Panel As above less n Enabling key switch

Description Code Number Callpoint. Master 82/00136 (a) Auxiliary. Master 82/00137 (b)

Certified by BSI to conform to EN 50291, with a 5 year manufacturer’s warranty. These alarms are Loud 85 decibel alarm with a flashing red light to warn when dangerous levels of CO are detected. They use proprietary electrochemical sensor technology with a self-diagnosing feature will indicate unit or sensor malfunction. Easy to install, with an automatic end- of-life warning after seven years, uses 3 x AA battery (supplied).

Additional features of the 900-0146 Digital Display alarm only

This alarm also has digital display continuously shows concentration of CO detected above 30ppm (parts per million), with peak level function to display the highest CO reading taken above 11ppm since the last peak level reset or power-up. The alarm is backlit display to take readings in the dark. DETECTION & ALARMS 37

Emergency Lighting

Thomas Glover Thomas Glover

e Section 4 4

f

Batteries (Ni-Cad Emergency Lighting Replacement Hi-Temp Ni-cad Battery, packs in C-Cell and D-Cell sizes A range of emergency luminaires in compliance to BSEN 60598-1, BSEN 4533-10Z, BSEN 60924 and suitable to be Description Code Number used in a BS5266 system. C Size Ni-Cad 3.6V 1.5 AH 82/00134 (e) Models available are D Size Ni-Cad 2.4V 4AH 82/00135 (f) Bricklite models IP65 giving 54 lumens output - available in NM and M modes all at 3 hours operation and featuring “The Friendly Clip Cover” Low profile standard IP20 giving 60 lumens output available in NM, M and S. All at 3 hours operation.

NM - Non maintained - lamp illuminated under mains failure M - Maintained - lamp switched under mains failure. S - Sustained - second lamp illuminated under mains failure. Features include • Friendly clip cover • Ni-Cad battery locater • Besa box mountings • Double insulated • Impregnated transformers and invertors Exit Boxes 8 watt wall mounted steel enclosures - 3 hours operation. Twin Spot Light Units 2 x 20 watt spots non maintained - metal enclosure - for commercial/ industrial use. Adhesive Eurogram Kits for bricklites and for low profiles

Description Code Number Metal exit box 8 watt maintained 82/00272 (a) 2 by 20 watt twin spot (excludes batteries) 82/00271 (b) IP65 bricklite 3 Hr. 8 watt maintained 82/00002 IP65 bricklite 3 Hr. 8 watt non-maintained 82/00001 (c) IP20 3Hr. 8 watt maintained 82/00006 IP20 3Hr. 8 watt non-maintained 82/00005 (d) Adhesive eurogram kit (bricklite) 82/00003 Adhesive eurogram kit for IP20 model 82/00004 38 DETECTION & ALARMS

Conventional Call Systems Test Equipment

No Climb Section 4 4

Canisters of “Ozone” friendly smoke suitable for testing ionisation or optical smoke detectors. The 150 ML hand held aerosol will provide up to 200 tests. The 250 ml

ystem & Test Equipment S ystem & Test aerosol is to be used with dispenser kit. Universal detector removal tool suitable for use with a Disabled Persons Toilet Alarm wide range of detectors from 65m to 110mm diameter. n Comes as complete kits Aerosol dispenser/tester for use with 250ml aerosol n Standard or economy kits - lightweight - n Many options on extras suitable for floor and ceiling voids. Transparent cup enables view of detector L.E.D. Description Code Number Extension pole to extend area of activity. Standard Kit 82/00231

Conventional Call Economy kit 82/00232 Description Code Number Aerosol smoke dispensor/tester 82/00199 (a) Aerosol Spray 150ml 82/00202 (b) Aerosol Spray 200ml (use with dispensers) 82/00200

Description Code Number Universal detector remover 82/00198 (c) 1.2 to 4.5 meter telescopic extension pole 82/00201

ACT

Intelligent Battery Tester The professional tester which shows on the L.C.D. by scrolling through. • Capacity • Voltage • Temperance

Description Code Number Intelligent Battery Tester Gold IBT 82/00396 (d) 39

Information Update Fire fighting foams containing Perfluorooctane Fire Safety Order (FSO) Sulphonate (PFOS) The Fire Safety Order will encompass and replace all existing fire The Department for Environment, Food and Rural Affairs (DEFRA) legislations: issued a consultation paper in October 2004 on UK proposals to • Fire Precautions Act 1971 introduce regulations on the restriction of use and marketing of • Fire Precautions (Workplace) Regulations 1997/1999 perfluorooctane sulphonate. • Management of Health and Safety in the Workplace PFOS, recently proved to be bioaccumulative, persistent, toxic and a Regulations 1999 • + 100 pieces of related legislation and risk to the aquatic and terrestrial environment, have been used in fire only apply in England and Wales. fighting foams for many years. Formulators, producers and users of PFOS in fire fighting foams will be Who will be affected by the FSO? affected by these proposals. It is thought that as substitutes exist for fire fighting foams a time limited derogation will be put in place before a • Non domestic premises total phase out of PFOS. If these proposals go ahead, fire fighting foams • All employers containing PFOS will have to be incinerated at high temperature. • Self employed How do I know if the extinguishers I buy contain PFOs? • Anyone responsible for a building to which the public The FIREPOWER range have been PFOS free since 2001. have access • Voluntary organisations Disability Discrimination Act 1995: Part III Since the 1st of October 2004 service providers have had a legal All premises affected by the FSO will have to carry out a fire risk requirement to make ‘reasonable adjustments’ to their premises to assessment. ensure disabled people can use their services. Aim of the FSO: Who is affected by the DDA? • Reduce the risk of fire and the spread of fire Everyone that provides paid or free goods, facilities or services to the • Extend protection explicitly to all occupants, not just public is defined as a service provider. Eg. Hotels, Restaurants, Retail employees shops, Schools, Hospitals, Theatres, Airports etc... • Protect the fire fighters What types of adjustments need to be made to the premises? • Protection of property These adjustments relate to the building’s ‘physical features’ i.e. For more information please log on to www.odpm.gov.uk entrances/exits, floor layouts, toilet facilities, printed materials, fire & safety provisions etc... Which Extinguisher to use

What is considered ‘reasonable’? Which A B C D F Extinguisher The Act does not list what particular adjustments should be made to a to use Freely burning Flammable Flammable Flammable Electrical Cooking oils building. The adjustments made will depend upon the size and resource materials. liquids gases metals Hazards and fat of the service provider and how practical it is to make these changes. Water Water with Disability can take many forms such as sight or hearing impairment, Additive physical and mobility problems, mental health problems or learning Spray Foam difficulties. These disabilities need to be taken into account when developing a fire safety strategy. ABC Dry Powder Thomas Glover offers a range of products that can help customers tailor Dry Powder their fire safety strategy to reflect the requirements of the DDA: Special Metal Dry Powder • Supplementing Fire Alarm bells with visual flashing beacons Special Monnex

to alert the hard of hearing C02 Gas

• Braille and tactile signs specifically designed for blind and Hose Reels partially sighted people Wet Chemical • Evacuation chairs and Dorgard to ease mobility through the building

For more information please log on to www.drc-gb.org Fire (Scotland) Act The Scottish Executive is proposing new primary legislation to consolidate existing fire regulatory requirements and to reform the operation of the fire and rescue service. For more information please log on to www.scotland.gov.uk