130813N001 BV SZ DR-3156 FCC 15C.231A
Total Page:16
File Type:pdf, Size:1020Kb
Test Report No.: RF130813N001 TEST REPORT Applicant ZHUHAI SUPER BRIGHT NEW ENERGY LIMITED NO.9 XINGWAN 6TH ROAD,HONGWAN COMMERCE&LOGISTICS Address ZHUHAI,CHINA Manufacturer or ZHUHAI SUPER BRIGHT NEW ENERGY LIMITED Supplier Address NO.9 XINGWAN 6TH ROAD,HONGWAN COMMERCE&LOGISTICS ZHUHAI,CHINA Product Intelligent Solar Light Brand Name N/A Model DR-3156 Additional Model & DR-0059, DR-0078, DR-3138, DR-0499, DR-3177; See section 3.1 Model Difference Date of tests Aug. 14, 2013 ~ Aug. 21, 2013 the tests have Been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.231a (2012-10) CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared By Venless long Approved By Glyn He Specialist / EMC Department Supervisor / EMC Department Thisreport isfor your exclusive use. Any copying or replication of thisreport to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Thisreport setsforth our findingssolely with respect to the test samplesidentified herein. The resultsset forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unlessspecifically and expressly noted. Our report includes all of the testsrequested By you and the resultsthereof Based upon the information that you provided to us. You have 60 days from date of issuance of thisreport to notify usof any material error or omission caused By our negligence, provided, however, that such notice shall Be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescriBed time shall constitute your unqualified acceptance of the completenessof thisreport, the testsconducted and the correctnessof the report contents. Unless specific mention, the uncertainty of measurement has Been explicitly taken into account to declare the compliance or non-compliance to the specification No. 34, Chenwulu Section, Guantai Rd., Houjie Tel: +86 769 8593 5656 Bureau Veritas Shenzhen Co., Ltd. Town, Dongguan City, Fax: +86 769 8593 1080 Dongguan Branch Guangdong 523942, China Email: [email protected] Page 1 of 26 Report Version 1 Test Report No.: RF130813N001 TABLE OF CONTENTS RELEASE CONTROL RECORD.............................................................................................................4 1 SUMMARY OF TEST RESULTS......................................................................................................5 2 MEASUREMENT UNCERTAINTY...................................................................................................5 3 GENERAL INFORMATION ..............................................................................................................6 3.1 GENERAL DESCRIPTION OF EUT ...........................................................................................6 3.2 DESCRIPTION OF TEST MODES.............................................................................................6 3.3 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL.............................................7 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................9 3.5 DESCRIPTION OF SUPPORT UNITS .......................................................................................9 4. TEST TYPES AND RESULTS........................................................................................................10 4.1 RADIATED EMISSION MEASUREMENT ................................................................................10 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .....................................................10 4.1.2 TEST INSTRUMENTS ..................................................................................................... 11 4.1.3 TEST PROCEDURES......................................................................................................12 4.1.4 DEVIATION FROM TEST STANDARD............................................................................12 4.1.5 TEST SETUP ...................................................................................................................13 4.1.6 EUT OPERATING CONDITIONS.....................................................................................13 4.1.7 TEST RESULTS...............................................................................................................14 4.2 20dB BANDWIDTH MEASUREMENT......................................................................................19 4.2.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT ..........................................................19 4.2.2 TEST INSTRUMENTS .....................................................................................................19 4.2.3 TEST PROCEDURE ........................................................................................................20 4.2.4 DEVIATION FROM TEST STANDARD............................................................................20 4.2.5 TEST SETUP ...................................................................................................................20 4.2.6 EUT OPERATING CONDITIONS ....................................................................................20 4.2.7 TEST RESULTS...............................................................................................................21 4.3 DEACTIVATION TEST..............................................................................................................22 4.3.1 LIMITS OF DEACTIVATION TEST ..................................................................................22 4.3.2 TEST INSTRUMENTS .....................................................................................................22 4.3.3 TEST PROCEDURE ........................................................................................................23 4.3.4 DEVIATION FROM TEST STANDARD............................................................................23 4.3.5 TEST SETUP ...................................................................................................................23 No. 34, Chenwulu Section, Guantai Rd., Houjie Tel: +86 769 8593 5656 Bureau Veritas Shenzhen Co., Ltd. Town, Dongguan City, Fax: +86 769 8593 1080 Dongguan Branch Guangdong 523942, China Email: [email protected] Page 2 of 26 Report Version 1 Test Report No.: RF130813N001 4.3.6 EUT OPERATING CONDITIONS ....................................................................................23 4.3.7 TEST RESULTS...............................................................................................................24 5 PHOTOGRAPHS OF THE TEST CONFIGURATION ....................................................................25 6 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ..................................................................................................................................26 No. 34, Chenwulu Section, Guantai Rd., Houjie Tel: +86 769 8593 5656 Bureau Veritas Shenzhen Co., Ltd. Town, Dongguan City, Fax: +86 769 8593 1080 Dongguan Branch Guangdong 523942, China Email: [email protected] Page 3 of 26 Report Version 1 Test Report No.: RF130813N001 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RF130813N001 Original release Aug. 21, 2013 No. 34, Chenwulu Section, Guantai Rd., Houjie Tel: +86 769 8593 5656 Bureau Veritas Shenzhen Co., Ltd. Town, Dongguan City, Fax: +86 769 8593 1080 Dongguan Branch Guangdong 523942, China Email: [email protected] Page 4 of 26 Report Version 1 Test Report No.: RF130813N001 1 SUMMARY OF TEST RESULTS The EUT hasBeen tested according to the following specifications: APPLIED STANDARD: FCC PART 15, SUBPART C (SECTION 15.231) STANDARD TEST TYPE AND LIMIT RESULT REMARK SECTION §15.203 Antenna Requirement PASS Compliant §15.207 (a) AC Power Conducted Emission N/A EUT ispowered By Battery §15.209 Radiated Emission PASS Compliant §15.231(B) §15.231 (a) Deactivation Testing PASS Compliant §15.231(c) Emission Bandwidth Measurement PASS Compliant 2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levelshave Been estimated for testsperformed on the EUT asspecified in CISPR 16-4-2: MEASUREMENT FREQUENCY UNCERTAINTY Conducted emissions 9kHz~30MHz 2.67dB 9KHz ~ 30MHz 2.5dB 30MHz ~ 1000MHz 4.81dB Radiated emissions 1GHz ~ 18GHz 4.3dB 18GHz ~ 40GHz 1.94dB Thisuncertainty representsan expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k= 2. No. 34, Chenwulu Section, Guantai Rd., Houjie Tel: +86 769 8593 5656 Bureau Veritas Shenzhen Co., Ltd. Town, Dongguan City, Fax: +86 769 8593 1080 Dongguan Branch Guangdong 523942, China Email: [email protected] Page 5 of 26 Report Version 1 Test Report No.: RF130813N001 3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT Intelligent Solar Light MODEL NO. DR-3156 FCC ID 2AAUTSOLARSYSTEM NOMINAL VOLTAGE DC 3.2V from Battery MODULATION TYPE ASK OPERATING FREQUENCY 433.85MHz NUMBER OF CHANNEL 1 ANTENNA TYPE Integral PCB Antenna I/O PORTS Refer to the user’smanual NOTE: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's manual. 2. For the test results, the EUT had Been tested with all