This is to attest that

AL BADER NUCLEAR & EQUIPMENT SERVICE CENTRE INDUSTRIAL AREA STREET NO. 41, GATE NO. 145 OPP. QBC READY-MIX, P.O. BOX 40570 DOHA, QATAR

Calibration Laboratory CL-138 has met the requirements of AC204, IAS Accreditation Criteria for Calibration Laboratories, and has demonstrated compliance with the ISO/IEC Standard 17025:2017, General requirements for the competence of testing and calibration laboratories. This organization is accredited to provide the services specified in the scope of accreditation maintained on the IAS website (www.iasonline.org).

This certificate is valid up to March 1, 2021.

(See laboratory’s scope of accreditation for fields of calibration and accredited calibration.)

This accreditation certificate supersedes any IAS accreditation bearing an earlier effective date. The certificate becomes invalid upon suspension, cancellation or revocation of accreditation. Raj Nathan See www.iasonline.org for current accreditation information, or contact IAS at 562-364-8201. President IAS Accreditation Number CL-138 Accredited Entity Al Bader Nuclear Gauge & Equipment Service Centre Address Main Office: Industrial Area, Street No.41, Gate No. 145 Opp. QBC Ready-mix, Po. Box 40570, Doha, Qatar Contact Name Khaled Naisa, Quality Leader Kumar Karki, Technical Leader Telephone +974 44983095 +974 44982151 Effective Date of Scope July 24, 2019 Accreditation Standard ISO/IEC 17025:2017

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Dimensional 0 mm to 150 mm 1.4 µm Optical Flat/Optical (Digital and 150 mm to 300 mm 6.8 µm Parallel/Slip Gauge Set Mechanical) 300 mm to 600 mm 7.8 µm /Length Bars Setting Masters for 0 mm to 150 mm 3 µm Digital Micrometer Micrometer (End Standards) Inside Micrometer 0 mm to 600 mm 12 µm Internal Micro Checker / Sticks Digital Micrometer Inside Micrometer 25 mm travel 7 µm Internal Micro Head Checker/Digital Micrometer Outside Caliper 0 mm to 300 mm 12 µm Internal Micro Checker/Slip (Vernier, Dial, 300 mm to 600 mm 13 µm Gauge Set (Gage Blocks) / Digital) Length Bars Inside Caliper 0 mm to 300 mm 8 µm Slip Gauge Set (Gage (Vernier, Dial, Blocks) / Length Bars Digital) Steel and 0 mm to 1000 mm 0.6 mm Tape and scale measuring Steel Tapes 0 mm to 5000 mm 1.7 mm machine Internal diameter 125 mm to 150 mm 18 µm Three point components 0 mm to 300 mm 12 µm Slip Gauge (Gage Blocks) / (Vernier, Dial, 300 mm to 600 mm 13 µm Optical Flat / Length Bars / Digital) Dial 0 mm to 10 mm 4 µm Dial Calibration Tester Indicator/Gauge 0 mm to 25 mm 6 µm Electronic Dial 0 mm to 25 mm 2 µm Digital Calibration Tester Indicator/Gauge 0 mm to 25 mm 8 µm with Display and Probe (Resolution 0.0001 mm) Pin Gauge 0 mm to 10 mm 3.2 µm Digital Micrometer Plain Plug Gauge 0 mm to 150 mm 3.5 µm Digital Micrometer

International Accreditation Service, Inc. 3060 Saturn Street, Suite 100, Brea, California 92821 U.S.A. Telephone +1 562-364-8201 — [email protected] www.iasonline.org Page 1 of 9

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Feeler Gauge 0 mm to 2 mm 3.3 µm Digital Micrometer Thickness Gauge 0 mm to 50 mm 7 µm Slip Gauges (Gage Blocks) (Mechanical and Electronic) Bore Gauge 0 mm to 2 mm 7 µm Dial Calibration Tester (Transmission Only, Mechanism Checks) Dial Calibration 0 mm to 25 mm 1.3 µm Slip Gauge Set (Gage Tester Blocks)/Optical Flat Test Sieve 63 µm to 2 mm 1.4 % Imaging Probe/Master 2.0 mm to 125 mm 0.4 % Sieve, Digital Caliper Straight Edge Straightness over 3 m span 14 μm set/ set/ Digital Indicator and Granite Surface Plate Compression / Flatness over 300 mm x 300 mm 11 μm Straightedge / Feeler Tension Machine Gauge set/ Gauge Block set Platens Angle (Bevel Up to 360º 40’ Using Imaging Probe Protector, Combination Set, Tri , Right Angle etc.) 0.5 mm to 50 mm 0.5 mm Measuring machine Digital or Level 0° to 60° 0.110 and gauge blocks Coating Thickness Gauges Ferrous 0 µm to 1507.15 µm 1.4 µm Coating thickness Non-Ferrous 0 µm to 1503.50 µm 1 µm standards Travelling Beam 0 mm to 25 mm 2.5 mm Granite Surface Plate 3m Apparatus by 1.9m, Gauge blocks Mechanical Nuclear Density 1775.4 kg/m3 0.3 % Using validator, ASTM Gauge – Density 2101.5 kg/m3 1.3 % D6938, Density Blocks 2143.1 kg/m3 1.1 % ASTM D7759 2174.3 kg/m3 1 % 2179.1 kg/m3 1.2 % 2188.8 kg/m3 1 % 2226.8 kg/m3 0.3 % 2685.7 kg/m3 0.3 % Nuclear Density 531.2 kg/m3 4.0 % Using validator, ASTM Gauge – Moisture 546.5 kg/m3 4.5 % D6938, Moisture Block, 549.5 kg/m3 4.0 % ASTM D7759 564.3 kg/m3 1.3 % 566.9 kg/m3 4.9 % 592.5 kg/m3 4.1 %

CL-138 Page 2 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Nuclear Density 0.01205 µCi (445.9 Bq) 0.000032 µCi Ludlum Model 3030 Alpha Gauge – 0.01618 µCi (598.7 Bq) Beta Counter, ISO Contamination 9978:1992 Leak Test6, 137Cs/241AmBe Force - 0.1 kN to 3336 kN 0.66 % Standard Load Cell Compression Compression FUTEK, MOREHOUSE and Machine AEP Transducers. Stability 1 kN to 2000 kN 0.16 % Reference Load cells Compression 0.1 kN to 3000 kN 0.17 % (FUTEK & MOREHOUSE) Proving Ring Reference Load cells Tension 0.01 to 50 kN 0.25 % (FUTEK & MOREHOUSE) Compression 0.001kN to 200 kN 0.27 % Torque 0 N·m to 500 N·m 0.6 % Norbar Torque Wrench and Calibrator Torque Screw Driver Pressure -1 bar to 2 bar 0.07 % FS Digital Pressure Gauge and 0 bar to 70 bar 0.1 % FS Ultrahigh Hydraulic 0 bar to 700 bar 0.36 % FS Comparator 0 bar to 2500 bar 0.12 % FS Pull of adhesion 0 psi to 3500 psi 5 psi Adhesion tester calibrator tester Moisture tester 0 psi to 20 psi 0.85 psi Moisture calibrator Volume 5 µL to 1000 µL 3.1 µL Balance and E-2 Class 1 mL to 500 mL 0.24 mL Weights, Gravimetric 500 mL to 2000 mL 5.7 mL method Air Content Meter 0 % to 15 % 0.24 % Concrete air meter calibrator with three 5 % cylinders Sound Level 94 dB and 114 dB 0.6 dB Extech sound level Meters (at 1 kHz) calibrator Balance 0 g to 220 g 0.16 mg E-1 Class Weights (in lab/ 0 g to 420 g 0.60 mg onsite) 0 g to 510 g 0.70 mg 0 g to 4200 g 8 mg 0 g to 12000 g 10 mg 0 g to 110 kg 35 g 0 g to 31 kg 0.1 g 0 g 200 g 0.61 mg E-2 Class Weights (in 200 g to 500 g 3.1 mg lab/onsite) 500 g to 1 kg 6.1 mg 1 kg to 5 kg 0.11 g 5 kg to 50 kg 0.81 g

CL-138 Page 3 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Electronic Balance 0 kg to 300 kg 0.13 kg F1 class weights Mass – Reference 0 mg to 1000 mg 1 mg Balance and E-2 Class Weights 1 g to 1000 g 1.2 mg Weights (Analytical and 1 kg to 20 kg 0.34g Bullion) Mass – Reference 1 mg 0.05 mg Balance and E-1 Class Weights Measure 20 mg 0.05 mg Weights 50 mg 0.05 mg 500 mg 0.05 mg 1 g 0.06 mg 20 g 0.065 mg 50 g 0.07 mg 200 g 0.23 mg 1 kg 1.6 mg 2 kg 1.8 mg 10 kg 0.03 g 20 kg 0.18 g 50 kg 0.2 g Hardness - 0 HRA to 100 HRA 0.9 HRA Rockwell Hardness Tester Rockwell 0 HRC to 100 HRC 1.0 HRC 0 HRBW to 100 HRBW 0.9 HRBW 17.9 HRC to 69.5 HRC 1 HRC Portable hardness tester Rubber Hardness 0 RHD to 100 RHD 2 RHD Durometer (Shore D) Hardness – Leeb 170 HLD to 960 HLD 6 HLD Portable hardness tester (Type D) Leeb Hardness 500 HLD to 900 HLD 1.8 HLD Certified Leeb Hardness Tester Block Rockwell Hardness 15 HRC to 20 HRC 1.4 HRC Indirect calibration using Tester 20 HRC to 65 HRC 0.8 HRC Master Hardness Blocks

Durometer for 20 Duro to 100 Duro 3 Duro Certified Duro A & Duro D hardness blocks for monitoring (Duro A & Duro D) calibration Impact 10 RN to 100 RN 1.1 RN ASTM C805/BSEN12504-2, for concrete Test hardness Wheel Tracker Parameters Static Load 158 lb 0.05 lb Hamburg Verification and Temperature Ambient to 100 ºC 0.2 ºC calibration device Displacement 0 mm to 45 mm 0.001 mm Shaker/Vibration Table Vibration Acceleration 200 m/s2 2.5 m/s2 Using Digital Vibration Velocity 200 m/s 3 mm/s Meter with Probe, ISO2954

CL-138 Page 4 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Air flow meter for 0.6 SLPM to 13 SLPM 0.1 SLMP Flow calibration system laminar flow FCS-8 Batching plant 0 kg to 3000 kg 1.7 kg Class F1 weights from 0 kg to 5000 kg 3.1 kg Troemner Gyratory Pressure: 200 kPa to 1000 kPa 12 kPa Load Cell compactor Angle: 0° to 1.5° 0.03° Dynamic angle validator Height: 114.38 mm 27 µm Height Standard Thermal Humidity Cabinet / 0 %RH to 95 %RH 3 %RH Humidity Recorder Chamber Oven, 0 ºC to 650 ºC 0.08 ºC Ametek Master Sensors/ Temperature Bath Ametek Digital Indicator Water Bath 0 ºC to 100 ºC 0.07 ºC Ametek Master Sensors/ Ametek Digital Indicator Incubator 0 ºC to 100 ºC 0.07 ºC Ametek Master Sensors/ Ametek Digital Indicator Muffle Furnace, 0 ºC to 1200 ºC 0.75 ºC Master Sensors/ Temperature Bath Temperature/Electrical Calibrator Freezer -40 ºC to 40 ºC 0.08 ºC Ametek Master Sensors/ Ametek Digital Indicator Contact Type 0 ºC to 100 ºC 0.05 ºC High Precision Digital Thermometer Thermometer Non-Contact -60 ºC to 200 ºC 1 ºC IR Calibrator / Thermal Surface 200 ºC to 500 ºC 1.5 ºC Imager Temperature / IR Thermometer Temperature -20 °C to 150 °C 0.06 °C Tempsens Liquid Bath and Indicator, Ametek Solid bath set with Controller with -40 °C to 650 °C 0.06 °C Digital Indicator and sensor Sensor (Pt100, Cu53), Temperature Gauge (Analog and Digital), Thermometer (Stick Type, Glass, Digital), RTDs, Thermocouple (Types B, E, J, K, R, S, and T) Oven profiling Temperature Deviation 0.98 °C Thermocouples, Time constant 0.8 s Fluke 1586, Rate of ventilation per hour 3/h Multiplexer & DAQ Scanner ASTM E145, ASTM D5374, ASTM D5423

CL-138 Page 5 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Hygrometer 0 °C to 50 °C 0.5 °C Thermotron Humidity 10 %RH to 90 %RH 2.1 %RH chamber Hydrometer 0.7 SG to 2 SG 0.12 SG Reference Hygrometers Electrical/DC/Low Frequency AC Current 1 µA to 100 µA 0.05 % Fluke 8846 A Digital Measure5 @50Hz 0.01 mA to 1 mA 4.6 % Multimeter 0.1 mA to 10 mA 0.46 % 1 mA to 100 mA 0.05 % 0.01 A to 1 A 4.6 % 0.03 A to 3 A 2.3 % 0.1 A to 10 A 0.69 % AC Voltage 1.0 mV to100 mV 0.12 % Fluke 8846 A Digital Measure5 @ 50Hz 0.01 V to 1 V 0.10 % Multimeter 0.1 V to 10 V 0.10 % 1 V to 100 V 0.10 % 10 V to 1000 V 0.02 % DC Current 0.01 µA 100 µA 0.03 % Fluke 8846 A Digital Measure5 0.507 mA to 1 mA 0.58 % Multimeter 2.007 mA to 10 mA 0.23 % 4.01 mA to 100 mA 0.01 % 0.0005 A to 1 A 2.31 % 0.0035 A to 3 A 0.77 % 0.018 A to 10 A 0.09 % DC Voltage 30.003 mV to 100 mV 0.84 % Fluke 8846 A Digital Measure5 0.006 V to 1 V 0.37 % Multimeter 0.004 V to 10 V 0.33 % 0.006 V to 100 V 0.51 % 0.006 V to 1000 V 0.59 % DC Resistance 0.003 Ω to 10 Ω 0.35 % Fluke 8846 A Digital Measure5 3.003 Ω to 100 Ω 0.0074 % Multimeter 0.05 kΩ to 1 kΩ 0.0015 % 0.05 kΩ to 10 kΩ 0.0019 % 0.05 kΩ to 100 kΩ 0.0014 % 0.01 MΩ to 1 MΩ 0.0012 % 0.01 MΩ to 10 MΩ 0.0019 % 0.4 MΩ to 100 MΩ 0.0002 % 1.01 GΩ to 1 GΩ 0.0043 % AC Current 29.00 µA to 329.999 µA Fluke 5522A Multi- Product Source4 (10 Hz to 30 kHz) 0.57 % Calibrator

0.33 mA to 3.29999 mA (10 Hz to 30 kHz) 0.0014 %

3.3 mA to 32.9999 mA (10 Hz to 30 kHz) 0.0005 %

CL-138 Page 6 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

AC Current 33 mA to 329.999 mA Fluke 5522A Multi- Product Source4 continued (10 Hz to 30 kHz) 0.0012 % Calibrator

1.1 A to 2.9999 A (10 Hz to 10 kHz) 3.1 % AC Voltage 1.0 mV to 32.999 mV Fluke 5522A Multi-Product Source4 (10 Hz to 500 kHz) 0.029 % Calibrator

33 mV to 329.999 mV (10 Hz to 500 kHz) 0.002 %

0.33 V to 3.29999 V (10 Hz to 500 kHz) 0.11 %

3.3 V to 32.9999 V (10 Hz to 100 kHz) 0.017 %

33 V to 329.999 V 0.019 % (45 Hz to 100 kHz)

330 V to 1020 V 0.004 % (45 Hz to 10 kHz) DC Current 0.002 µA to 329.999 µA 0.0004 % Fluke 5522A Multi- Product Source4 0.00002 mA to 3.29999 mA 0.0036 % Calibrator 0.0002 mA to 32.9999 mA 0.0004 % 0.002 mA to 329.999 mA 0.004 % 0.00002 A to 1.09999 A 0.028 % 1.1 A to 2.99999 A 0.025 % 0.0002 A to 10.9999 A 0.017 % DC Voltage 0.001 mV to 329.9999 mV 0.00059 % Fluke 5522A Multi- Product Source4 0.00001 V to 3.299999 V 0.00065 % Calibrator 0.0001 V to 32.99999 V 0.00050 % 30 V to 329.9999 V 0.00043 % 100 V to 1020.000 V 0.00040 % DC High Voltage 0.5 kV to 70 kV 58 V Precision High Voltage Source4 meter & Precision High Voltage probe DC Resistance 0.001 Ω to 10.9999 Ω 0.0025 % Fluke 5522A Multi- Product Source4 11 Ω to 32.9999 Ω 0.0012 % Calibrator 33 Ω to 109.9999 Ω 0.0007 % 110 Ω to 329.9999 Ω 0.0006 % 330 Ω to 1.099999 kΩ 0.0004 % 1.1 kΩ to 3.299999 kΩ 0.0007 % 3.3 kΩ to 10.99999 kΩ 0.0006 % 11 kΩ to 32.99999 kΩ 0.0004 % 33 kΩ to 109.9999 kΩ 0.0004 % 110 kΩ to 329.9999 kΩ 0.0005 %

CL-138 Page 7 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

DC Resistance 330 kΩ to 1.099999 MΩ 0.0009 % Fluke 5522A Multi- Product Source4 continued 1.1 MΩ to 3.299999 MΩ 0.0012 % Calibrator 3.3 MΩ to 10.99999 MΩ 0.0014 % 11 MΩ to 32.99999 MΩ 0.0103 % 33 MΩ to 109.9999 MΩ 0.014 % 110 MΩ to 329.9999 MΩ 0.061 % 330 MΩ to 1100 MΩ 0.11 % Simulated Temperature (Temperature Controller / Indicator / Recorder / Scanner) Thermocouples Type B 600 ºC to 1820 ºC 0.5 ºC Fluke 5522A Multiproduct Type R -50 ºC to 1768 ºC 0.5 ºC Calibrator, temperature Type S -50 ºC to 1768 ºC 0.5 ºC sensor or thermocouple not Type E -270 ºC to 1000 ºC 0.5 ºC attached Type J -210 ºC to 1200 ºC 0.5 ºC Type K -270 ºC to 1372 ºC 0.5 ºC Type N -270 ºC to 1300 ºC 0.5 ºC Type T -270 ºC to 400 ºC 0.5 ºC Type U -200 ºC to 600 ºC 0.5 ºC Type L -200 ºC to 900 ºC 0.5 ºC Type C, G, D 0 ºC to 2315 ºC 0.5 ºC RTDs Pt50 and Pt100 -200 ºC to 850 ºC 0.5 ºC Ni100 -60 ºC to 180 ºC 0.5 ºC Ni120 -80 ºC to 260 ºC 0.5 ºC Cu10 -200 ºC to 260 ºC 0.5 ºC Time/Frequency Frequency 5 Hz to 10 Hz 0.58 % Fluke 8846 A Digital Measure5 40 Hz to 300 kHz 0.32 % Multimeter 300 kHz to 1 MHz 0.48 % Rotational Speed 1 rpm to 11000 rpm 2.5 rpm Tachometer Non-contact 3 rpm to 99 rpm 0.4 rpm Tachometer calibrator Tachometer 100 rpm to 999 rpm 1.5 rpm 1000 rpm to 9999 rpm 4 rpm 10000 rpm to 99999 rpm 13 rpm Stopwatch/Timer 0 h to 24 h 0.3 s Master Stopwatch and Manual Comparison

CL-138 Page 8 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)1,2

CALIBRATION EXPANDED TECHNIQUE, REFERENCE RANGE AREA UNCERTAINTY3 (±) STANDARD, EQUIPMENT

Chemical pH 4.0 pH 0.03 pH Traceable buffer solutions 7.0 pH 0.03 pH 10.2 pH 0.03 pH Conductivity 5 µS/cm to 500 mS/cm 0.75 % Traceable conductivity solutions

1The uncertainty covered by the Calibration and Measurement Capability (CMC) is expressed as the expanded uncertainty having a specific coverage probability of approximately 95 %. It is the smallest measurement uncertainty that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than that provided in the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.

2If information in this CMC is presented in non-SI units, the conversion factors stated in NIST Special Publication 811 “Guide for the Use of the International System of Units (SI)” apply.

3When uncertainty is stated in relative terms (such as percent, a multiplier expressed as a decimal fraction or in scientific notation), it is in relation to instrument reading or instrument output, as appropriate, unless otherwise indicated.

4Capability is suitable for the calibration of measuring devices in the stated ranges.

5Capability is suitable for the calibration of devices intended to generate the measurand in the stated ranges.

6The contamination leak test is performed as part of the calibration of nuclear density gauges, and is not considered a calibration in itself, but is listed here for completeness. The stated uncertainty is based on the repeatability of the test only.

FS = Full Scale SLPM = standard litre per minute SG = specific gravity RN = rebound number

CL-138 Page 9 of 9 AL BADER NUCLEAR GAUGE & EQUIPMENT SERVICE CENTRE