Special Cables ELSEWEDY CABLES IN BRIEF

Elsewedy Cables was established in 1984 and is considered as one of the oldest and most successful industrial and trading business groups across the Middle East and Africa in the fields of energy, plastics and contracting. Elsewedy Cables is specialized mainly in Wires, Cables, Telecom Solutions, Electrical Products, Turnkey Projects, and recently Energy Generation. The group’s turnover has been rapidly rising during the past few years to reach $ 1.5 billion in 2007, also, the production capacity is the second highest one in the region, with 125000 tons/ annum, expecting 212000 tons/annum in 2008. Although the company began as an Egyptian local manufacturer, it has branched out regionally and internationally to include 23 production facilities for cables and electrical products that are located in 12 contries (, Sudan, , Zambia, Ghana, Syria, , Qatar, Slovenia, India and Malaysia), and it currently export its wide range of high quality and safe products to more than 110 countries worldwide. Additionally, the group’s outstanding human potential, which is more than 5000 employees, and its solid financial postioin, along with the strong geographical prsensce, have heavily contributed to the group’s success and prosperity.

To strengthen its position world wide, and following the corporate strategy, on the one hand, Elsewedy Cables fully acquired by the end of 2007 ISKRAEMECO, a leader manufacturer of electrometers and currently the third largest player in the European market and the seventh largest globally; on the other hand, Elsewedy Cables is involved with 74% ownership jointly with Glencore International in a 850 $US million project for the construction of a copper smelter to be located in Egypt. ELSEWEDY CABLES IN BRIEF

Further more, Elsewedy Cables provides a complete portfolio of solutions and advanced technologies for sectors as diverse as the automotive and aerospace industries, railways, buildings, telecommunication and energy networks, oil and gas, submarine power systems, etc. Accordingly, Elsewedy Cables is divided in three segments in order to cover all those sectors: Wires & cables, electrical products, and turn-key projects. The group has obtained quality certificates from the most reputable laboratories, among them: ISO 90012000-, ISO 14001, QS 9000, KEMA.a Quality and safety are so much considered. Elsewedy Cables adopted a policy that assures maximum effectiveness and efficiency through processes and systems ensuring that every aspect of each company’s activity is aligned to satisfy customer needs and all other objectives without wasting effort and with the use of the full potential of every person. Our organizational philosophy believes that customer satisfaction, health, safety, environmental considerations, and business objectives are mutually dependent. In the industrial sector, we currently supply approximately 56% of Egypt’s global market share of power cables, telecommunication cables, and lighting industries. In the export sector, as part of a worldwide marketing plan, Elsewedy Cables has branches throughout Africa, Middle East, Gulf Area, Europe, and Asia, and consistently showing dramatic increases; Egypt enjoys an important number of trade agreements with most of those countries (EU Agreement, Arab Free Trade Agreement, COMESA Agreement). Nowadays, Elsewedy Cables is exporting approximately 60% of its total turnover (export value of 550 $US million in 2006, 1 $US billion in 2007). For that reason, the group is concentrating efforts and making investments to target market segments and countries world wide with strong growth potential, such as Europe, Asia, or Latin America, although strengthen its leadership in Africa and Middle East. Elsewedy Cables’ mission is to become world expert in cables, with a strong financial basis and technical advanced product portfolio, making it an attractive partner for all its stakeholders: Shareholders, customers, suppliers, and employees. Group History

1938 Elsewedy family started its business as a trader in electrical equipment. 1960 The business was developed further by turning into a distributor for the only cables manufacturing at that time. 1984 Based on their experience in that field, the family decided to build Egypt’s first private sector cables factory “ARAB CABLES”. 1986 Arab Cables started production as Egypt’s and the Middle East’s private sector cables supplier. 1986-96 Arab Cables’ capacity quadruples from around 6.000 tons of copper cables in 1986 to 30.000 tons in 1996. 1996 Elsewedy family established their second factory, “EGYTECH CABLES”, which is the most advanced cables production facility in the Middle East with an annual capacity of 30.000 tons of copper cables and 15.000 tons of aluminum cables. Elsewedy family established their first plant for producing PVC compounds and master batch for cables insulation “SEDPLAST” considered as major component for the production of cables. 1997 Elsewedy family established “UNITED INDUSTRIES”, the company consists of three different factories specialized in the production of special cables (first factory in Egypt), winding wires & fiber glass poles. Elsewedy family established “ELASTIMOLD EGYPT”, as a joint venture with ELastimold, a unit of Thomas & Betts, one of the leading companies worldwide in the field of cables accessories, to produce power cable joints and Modular Terminators. 1998 Elsewedy family established “UNITED METALS CO.” Egypt’s first factory to produce High Grade Copper Rods, the main component in the production of cables conductors. The factory is considered as the largest copper rod factory in the Middle East region. Elsewedy family established “Elsewedy SEDCO”, as the first and only factory in Africa and the Middle East producing cable accessories. 2002 Elsewedy Cables established their first cables factory outside Egypt “GIAD Elsewedy Cables” in partnership with the Sudanese company Giad for the production of power cables, over head conductors and telephone cables. 2003 Elsewedy Cables further enhances their facilities outside Egypt by establishing the “SUDANESE EGYPTAION ELECTRICAL INDUSTRIES CO.” in partnership with Sudanese electricity authority. SUDATRAF (specialized in manufacturing transformers, electrical panels & cables joint and terminators). 2004 Together Elsewedy Cables Group & Italsmea company (Italy) established a joint venture for the manufactory of explosion proof electrical equipment. Italsmea Elsewedy co. 2005 Elsewedy Cables established the Syria’s latest cables factory “Elsewedy Cables SYRIA” specialized in power cables manufacturing up to 400 kV, relying on the growth in the area of: Syria, Lebanon, Jordan, Iraq, Iran, Palestine and all Arab countries near by. 2006 Elsewedy Cables penetrated Ghana, by establishing “Elsewedy ELECTRIC-GHANA” the factory is specialized in Fiber Glass Road Lighting Poles manufacturing. 2007 Elsewedy Cables established two new factories: Elsewedy Cables SAUDI ARABIA specialized in wires and cables. Elsewedy ELECTRIC SYRIA specialized in transformers. Acquisition of ISKRAEMECO specialized in energy measurement & management systems. 2008 Elsewedy Cables established two new factories: Elsewedy Cables Qatar: specialized in power cables “Low & Medium”. Elsewedy Cables Algeria: specialized in power cables “Low & Medium” in addition to instrumentation cables. Group structure

Wires & Cables United Metals

Sedplast

Sedco Egyplast

Elastimold Egypt United Wires Elsewedy Transformers Egypt Red Sea Copper Sudanese Egyptian Electrical Industries Arab Cables Elsewedy Electric Syria Egytech Cables Elsewedy Electric Ghana

United Industries Elsewedy Electrical Products Electric Zambia

Elsewedy Cables ISKRAEMECO Egypt

Giad Elsewedy Cables

Elsewedy Cables Syria

Elsewedy Cables Algeria Elsewedy Electric Turnkey Projects Transmission & Elsewedy Distribution Cables Saudi Arabia PSP Elsewedy Power Systems Libya Projects Cables index

A Instrumentation Cables B Fire Resistant & Fire Alarm Cables C Control Cables D Lan and Telephone Cables E Coaxial Cables F Automotive Wires G Appliance Cables and Cords H Technical Information I Glossary J Certificates High Resolution Pls A. Instrumentation Cables A. Instrumentation Cables

PVC Insulation, Multipairs, Twisted in Bundles, Collective Screen...... 2 PVC Insulation, Single Pair or Triple, Collective Screen...... 3 PVC Insulation, Multipairs, Layers, Collective Screen...... 4 PVC Insulation, Multipairs, Layers, Individual and Collective Screen...... 6 PVC Insulation, Multitriples, Layers, Collective Screen...... 8 PVC Insulation, Multitriples, Layers, Individual and Collective Screen...... 10 PVC Insulation, Single Pair, Collective Screen, Galvanized Steel Wire Armour...... 12 PVC Insulation, Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour...... 13 PVC Insulation, Individual and Collective screen, Galvanized Steel wire Armour...... 15 PVC Insulation, Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour...... 16 PE Insulation, Multipairs, Twisted in Bundles, Collective Screen...... 17 PE Insulation, Single Pair or Triple, Collective Screen...... 18 PE Insulation, Multipairs, Layers, Collective Screen...... 19 PE Insulation, Multipairs, Layers, Individual and Collective Screen...... 21 PE Insulation, Multitriples, Layers, Collective Screen...... 23 PE Insulation, Multitriples, Layers, Individual and Collective Screen...... 25 PE Insulation, Single Pair, Collective Screen, Galvanized Steel Wire Armour...... 27 PE Insulation, Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour...... 28 PE Insulation, Multipairs, Layers, Collective Screen Galvanized Steel Wire Armour...... 29 PE Insulation, Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour...... 30 PE Insulation, Multicores, Layers, Overall Screen of Tinned Copper Wire Braid...... 32 PE Insulation, Single Pair, Collective Screen of Tinned Copper Wire Braid...... 33 PE Insulation, Multipairs, Layers, Overall Screen of Tinned Copper Wire Braid...... 34 PE Insulation, Multipairs, Layers, Overall Screen of Plain or Tinned Copper Wire Braid...... 35 PVC Insulation Multipairs, Twisted in Bundles, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Wrapping: BS 5308-2 Polyester tapes

Rated Voltage: Collective Screen: 300/500 V Aluminum polyester tape with tinned drain wire and wrapped by polyester tapes Conductor: Stranded annealed plain copper Sheath: Polyvinylchloride TM1 to BS 6746 colour black or grey Insulation: or blue

Polyvinylchloride TI1 to BS 6746 UIC Elsewedy Instrumentation Cables 225 V Minimum bending radius: Assembly: 7.5*d (d= overall diameter) Cores twisted to form pairs, 4 pairs twisted to form a bundle, bundles twisted in concentric Temperature rating: layers, 2 pairs twisted as star quad +5oC up to + 50oC during operaion

Colour code: Packing: One Pair : Blue / Red On non-returnable wooden drums Two Pairs : Grey / Yellow Three Pairs : Green / Brown Four Pairs : White / Black Bundles are identified by coloured polyester tapes.

Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC - code size pairs No.x dia. Res. At thickness thickness diameter weight 20oC No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 2 7 x 0.3 39.2 0.6 1.0 7.9 80 CPC-T1202-JU05GQ 4 7 x 0.3 39.2 0.6 1.0 10.1 100 CPC-T1204-JU05GQ 8 7 x 0.3 39.2 0.6 1.0 12.1 160 CPC-T1208-JU05GQ 0.5 12 7 x 0.3 39.2 0.6 1.2 14.4 230 CPC-T1212-JU05GQ 16 7 x 0.3 39.2 0.6 1.2 16.1 300 CPC-T1216-JU05GQ 20 7 x 0.3 39.2 0.6 1.2 18.5 360 CPC-T1220-JU05GQ 24 7 x 0.3 39.2 0.6 1.4 20.3 450 CPC-T1224-JU05GQ 2 7 x 0.43 18.4 0.6 1.0 8.9 100 CPC-T1202-JU12GQ 4 7 x 0.43 18.4 0.6 1.0 12 160 CPC-T1204-JU12GQ 8 7 x 0.43 18.4 0.6 1.2 16 300 CPC-T1208-JU12GQ 1.0 12 7 x 0.43 18.4 0.6 1.4 20 430 CPC-T1212-JU12GQ 16 7 x 0.43 18.4 0.6 1.4 22 550 CPC-T1216-JU12GQ 20 7 x 0.43 18.4 0.6 1.4 24.3 660 CPC-T1220-JU12GQ 24 7 x 0.43 18.4 0.6 1.6 26.7 800 CPC-T1224-JU12GQ

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 2 PVC Insulation Single Pair or Triple, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Screen: BS 5308-2 Collective screen aluminum polyester tape with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300/500 V Sheath: Conductor: Polyvinylchloride TM1 to BS 6746 colour black or grey Stranded annealed plain copper or blue

Insulation: Minimum bending radius:

Polyvinylchloride TI1 to BS 6746 7.5*d (d= overall diameter) UIC Elsewedy Instrumentation Cables 300 V

Assembly: Temperature rating: cores twisted to form a pair or triple and +5oC up to + 50oC during operaion wrapped by polyester tapes Packing: Colour code: On non-returnable wooden drums Pair : White / Black Triple : Black / White / Red

Technical Information Conductor Nominal Nominal Approximate Approximate Cable Size Max. DC insulation sheath overall net UIC - code No.x dia. Res. At thickness thickness diameter weight 20oC mm2 No. x mm Ohm /Km mm mm mm Kg/Km - 1x 2 x 0.5 7 x 0.3 39.2 0.6 0.8 6.0 50 CPC-T1201-JU05B 1x 3 x 0.5 7 x 0.3 39.2 0.6 0.8 6.3 60 CPC-T1301-JU05B 1x 2 x 0.75 7 x 0.37 24.6 0.6 0.8 6.4 60 CPC-T1201-JU08B 1x 3 x 0.75 7 x 0.37 24.6 0.6 0.8 6.7 70 CPC-T1301-JU08B 1x 2 x 1.0 7 x 0.43 18.4 0.6 0.8 6.8 70 CPC-T1201-JU12B 1x 3 x 1.0 7 x 0.43 18.4 0.6 0.8 7.1 80 CPC-T1301-JU12B 1x 2 x 1.3 7 x 0.49 14.2 0.6 0.8 7.1 80 CPC-T1201-JU14B 1x 3 x 1.3 7 x 0.49 14.2 0.6 0.8 7.4 90 CPC-T1301-JU14B 1x 2 x 1.5 7 x 0.53 12.6 0.6 0.8 7.6 90 CPC-T1201-JU15B 1x 3 x 1.5 7x 0.53 12.6 0.6 0.8 8.0 110 CPC-T1301-JU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 3 PVC Insulation Multipairs, Layers, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Collective Screen: BS 5308-2 Aluminium polyster tape with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300/500 V Sheath: Polyvinylchloride TM1 to BS 6746 colour Conductor: black or grey or blue Stranded annealed plain copper Minimum bending radius: Insulation: 7.5 x d (d= overall diameter) Polyvinylchloride TI1 to BS 6746 UIC Elsewedy Instrumentation Cables 300 V Temperature rating: o o Assembly: +5 C up to + +50 C during operation Cores twisted to form pairs, twisted pairs in concentric layers and wrapped by polyester Packing: tapes On non-returnable wooden drums

Colour code: Black / White, continuously numbered, or identification tapes numbered

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC Res. insulation sheath overall net UIC - code size No.x dia. pairs At 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.0 9.3 107 CPC-T1202-JU05B 4 7 x 0.3 39.2 0.6 1.0 10.0 117 CPC-T1204-JU05B 8 7 x 0.3 39.2 0.6 1.2 13.2 199 CPC-T1208-JU05B 12 7 x 0.3 39.2 0.6 1.2 15.0 265 CPC-T1212-JU05B 0.5 16 7 x 0.3 39.2 0.6 1.2 16.7 340 CPC-T1216-JU05B 20 7 x 0.3 39.2 0.6 1.3 18.7 410 CPC-T1220-JU05B 24 7 x 0.3 39.2 0.6 1.3 20.6 480 CPC-T1224-JU05B 30 7 x 0.3 39.2 0.6 1.5 23.3 685 CPC-T1230-JU05B 2 7 x 0.37 24.6 0.6 1.0 10.1 125 CPC-T1202-JU08B 4 7 x 0.37 24.6 0.6 1.0 10.8 140 CPC-T1204-JU08B 8 7 x 0.37 24.6 0.6 1.2 14.3 245 CPC-T1208-JU08B 12 7 x 0.37 24.6 0.6 1.2 16.3 330 CPC-T1212-JU08B 0.75 16 7 x 0.37 24.6 0.6 1.3 18.3 430 CPC-T1216-JU08B 20 7 x 0.37 24.6 0.6 1.3 20.3 520 CPC-T1220-JU08B 24 7 x 0.37 24.6 0.6 1.3 22.5 610 CPC-T1224-JU08B 30 7 x 0.37 24.6 0.6 1.5 23.3 720 CPC-T1230-JU08B

A 4 PVC Insulation Multipairs, Layers, Collective Screen

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. pairs 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm/Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.0 10.8 142 CPC-T1202-JU12B 4 7 x 0.43 18.4 0.6 1.0 11.6 166 CPC-T1204-JU12B 8 7 x 0.43 18.4 0.6 1.2 15.4 295 CPC-T1208-JU12B

1.0 12 7 x 0.43 18.4 0.6 1.3 17.8 415 CPC-T1212-JU12B 16 7 x 0.43 18.4 0.6 1.3 19.8 532 CPC-T1216-JU12B 20 7 x 0.43 18.4 0.6 1.3 22.0 641 CPC-T1220-JU12B 24 7 x 0.43 18.4 0.6 1.5 24.8 784 CPC-T1224-JU12B 30 7 x 0.43 18.4 0.6 1.7 27.5 1063 CPC-T1230-JU12B 2 7 x 0.49 14.2 0.6 1.0 11.7 160 CPC-T1202-JU14B 4 7 x 0.49 14.2 0.6 1.2 13.3 230 CPC-T1204-JU14B 8 7 x 0.49 14.2 0.6 1.3 16.5 375 CPC-T1208-JU14B 12 7 x 0.49 14.2 0.6 1.3 19.3 400 CPC-T1212-JU14B 1.3 16 7 x 0.49 14.2 0.6 1.3 21.7 590 CPC-T1216-JU14B 20 7 x 0.49 14.2 0.6 1.5 24.2 815 CPC-T1220-JU14B 24 7 x 0.49 14.2 0.6 1.7 26.3 950 CPC-T1224-JU14B 30 7 x 0.49 14.2 0.6 1.7 31.0 1300 CPC-T1230-JU14B 2 7 x 0.53 12.6 0.6 1.2 12.9 202 CPC-T1202-JU15B 4 7 x 0.53 12.6 0.6 1.2 14.1 243 CPC-T1204-JU15B 8 7 x 0.53 12.6 0.6 1.3 18.6 425 CPC-T1208-JU15B 12 7 x 0.53 12.6 0.6 1.3 21.3 594 CPC-T1212-JU15B 1.5 16 7 x 0.53 12.6 0.6 1.5 24.3 797 CPC-T1216-JU15B 20 7 x 0.53 12.6 0.6 1.5 27.1 963 CPC-T1220-JU15B 24 7 x 0.53 12.6 0.6 1.7 30.3 1164 CPC-T124-JU15B 30 7 x 0.53 12.6 0.6 2.0 33.7 1595 CPC-T1230-JU15B • The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 5 PVC Insulation Multipairs, Layers, Individual and Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Sheath: BS 5308-2 Polyvinylchloride TM1 to BS 6746 colour black or blue

Rated Voltage: Minimum bending radius: 300/500 V 7.5 x d (d= overall diameter)

Conductor: Temperature rating: Stranded annealed plain copper +5oC up to +50oC during operaion

Insulation: Packing: Polyvinylchloride TI1 to BS 6746 On non-returnable wooden drums UIC Elsewedy Instrumentation Cables 300 V Assembly: Cores twisted to form pairs, pairs screened by aluminum polyester tape, screened pairs twisted in concentric layers, and wrapped by polyester tapes

Screen: Collective screen of aluminum polyester tape with tinned drain wire and wrapped by polyester tapes

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC - code size pairs No.x dia. Res. At thickness thickness diameter weight 20oC

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.0 10.3 122 CPC-T1202-SU05B 4 7 x 0.3 39.2 0.6 1.0 11.1 140 CPC-T1204-SU05B 8 7 x 0.3 39.2 0.6 1.2 14.7 240 CPC-T1208-SU05B 12 7 x 0.3 39.2 0.6 1.3 17.0 340 CPC-T1212-SU05B 0.5 16 7 x 0.3 39.2 0.6 1.3 18.9 433 CPC-T1216-SU05B 20 7 x 0. 3 39.2 0.6 1.3 21.0 518 CPC-T1220-SU05B 24 7 x 0. 3 39.2 0.6 1.5 23.7 636 CPC-T1224-SU05B 30 7 x 0. 3 39.2 0.6 1.5 26.3 867 CPC-T1230-SU05B 2 7 x 0.37 24.6 0.6 1.0 11.2 149 CPC-T1202-SU08B 4 7 x 0.37 24.6 0.6 1.0 11.9 165 CPC-T1204-SU08B 8 7 x 0.37 24.6 0.6 1.2 15.8 291 CPC-T1206-SU08B 12 7 x 0.37 24.6 0.6 1.3 18.3 409 CPC-T1208-SU08B 0.75 16 7 x 0.37 24.6 0.6 1.3 20.4 523 CPC-T1212-SU08B 20 7 x 0.37 24.6 0.6 1.3 22.8 631 CPC-T1216-SU08B 24 7 x 0.37 24.6 0.6 1.5 25.7 770 CPC-T1220-SU08B 30 7 x 0.37 24.6 0.6 1.7 26.4 902 CPC-T1230-SU08B

A 6 PVC Insulation Multipairs, Layers, Individual and Collective Screen

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC - code size pairs No.x dia. Res. At thickness thickness diameter weight 20oC

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.2 12.2 172 CPC-T1202-SU12B 4 7 x 0.43 18.4 0.6 1.2 13.1 201 CPC-T1204-SU12B 8 7 x 0.43 18.4 0.6 1.3 17.2 351 CPC-T1208-SU12B 12 7 x 0.43 18.4 0.6 1.3 19.7 486 CPC-T1212-SU12B 1.0 16 7 x 0.43 18.4 0.6 1.3 21.9 626 CPC-T1216-SU12B 20 7 x 0.43 18.4 0.6 1.5 25.0 670 CPC-T1220-SU12B 24 7 x 0.43 18.4 0.6 1.5 27.6 923 CPC-T1224-SU12B 30 7 x 0.43 18.4 0.6 1.7 30.5 1253 CPC-T1230-SU14B 2 7 x 0.49 14.2 0.6 1.2 12.8 195 CPC-T1202-SU14B 4 7 x 0.49 14.2 0.6 1.3 14.0 245 CPC-T1204-SU14B 8 7 x 0.49 14.2 0.6 1.3 18.2 425 CPC-T1208-SU14B 12 7 x 0.49 14.2 0.6 1.3 20.3 615 CPC-T1212-SU14B 1.3 16 7 x 0.49 14.2 0.6 1.5 23.2 790 CPC-T1216-SU14B 20 7 x 0.49 14.2 0.6 1.5 27.0 880 CPC-T1220-SU14B 24 7 x 0.49 14.2 0.6 1.7 31.2 1100 CPC-T1224-SU14B 30 7 x 0.49 14.2 0.6 2.0 34.5 1450 CPC-T1230-SU14B 2 7 x 0.53 12.6 0.6 1.2 14.1 228 CPC-T1202-SU15B 4 7 x 0.53 12.6 0.6 1.2 15.4 273 CPC-T1204-SU15B 8 7 x 0.53 12.6 0.6 1.3 20.3 480 CPC-T1208-SU15B 12 7 x 0.53 12.6 0.6 1.5 24.0 700 CPC-T1212-SU15B 1.5 16 7 x 0.53 12.6 0.6 1.5 26.7 904 CPC-T1216-SU15B 20 7 x 0.53 12.6 0.6 1.7 30.2 1119 CPC-T1220-SU15B 24 7 x 0.53 12.6 0.6 2.0 34.0 1370 CPC-T1224-SU15B 30 7 x 0.53 12.6 0.6 2.2 37.4 1845 CPC-T1230-SU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 7 PVC Insulation Multitriples, Layers, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Wrapping: BS 5308-2 Polyester tapes

Rated Voltage: Collective Screen 300/500 V Aluminum polyester tape with tinned drain wire and wrapped by polyester tapes

Conductor: Sheath: Stranded annealed plain copper Polyvinylchloride TM1 to BS 6746 colour black or grey or blue Insulation:

Polyvinylchloride TI1 to BS 6746 Minimum bending radius: UIC Elsewedy Instrumentation Cables 300 V 7.5 x d (d= overall diameter) Assembly: Cores twisted to form triples, twisted triples in Temperature rating: concentric layers, and wrapped by polyester +5oC up to +50oC during operation tapes. Packing: Colour code: On non-returnable wooden drums Black / White / Red, continuously numbered, or identification tapes numbered Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC - code size No.x Res. triples dia. o thickness thickness diameter weight At 20 C

2 No. x Ohm mm No. mm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.0 10.1 125 CPC-T1302-JU05B 4 7 x 0.3 39.2 0.6 1.0 10.8 150 CPC-T1304-JU05B 8 7 x 0.3 39.2 0.6 1.2 14.6 245 CPC-T1308-JU05B 12 7 x 0.3 39.2 0.6 1.3 16.5 347 CPC-T1312-JU05B 0.5 16 7 x 0.3 39.2 0.6 1.3 18.7 450 CPC-T1316-JU05B 20 7 x 0.3 39.2 0.6 1.3 21.2 565 CPC-T1320-JU05B 24 7 x 0.3 39.2 0.6 1.5 24.0 670 CPC-T1324-JU05B 30 7 x 0.3 39.2 0.6 1.5 27.7 975 CPC-T1330-JU05B 2 7 x 0.37 24.6 0.6 1.0 10.9 145 CPC-T1302-JU08B 4 7 x 0.37 24.6 0.6 1.0 11.8 190 CPC-T1304-JU08B 8 7 x 0.37 24.6 0.6 1.3 15.9 375 CPC-T1308-JU08B 12 7 x 0.37 24.6 0.6 1.3 17.9 435 CPC-T1312-JU08B 0.75 16 7 x 0.37 24.6 0.6 1.3 20.2 535 CPC-T1316-JU08B 20 7 x 0.37 24.6 0.6 1.5 23.8 675 CPC-T1320-JU08B 24 7 x 0.37 24.6 0.6 1.5 26.0 970 CPC-T1324-JU08B 30 7 x 0.37 24.6 0.6 1.7 30.0 1175 CPC-T1330-JU08B

A 8 PVC Insulation Multitriples, Layers, Collective Screen

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor Max. DC of No.x insulation sheath overall net UIC – code size Res. At triples dia. thickness thickness diameter weight 20oC No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 2 7 x 0.43 18.4 0.6 1.2 12.1 170 CPC-T1302-JU12G 4 7 x 0.43 18.4 0.6 1.2 13.6 255 8 7 x 0.43 18.4 0.6 1.3 17.6 430 CPC-T1308-JU12G 1.0 12 7 x 0.43 18.4 0.6 1.3 20.3 590 16 7 x 0.43 18.4 0.6 1.3 22.8 750 CPC-T1316-JU12G 20 7 x 0.43 18.4 0.6 1.5 25.6 930 24 7 x 0.43 18.4 0.6 1.5 27.6 1090 CPC-T1324-JU12G 30 7 x 0.43 18.4 0.6 1.7 33.2 1325 2 7 x 0.49 14.2 0.6 1.2 12.8 200 CPC-T1302-JU14G 4 7 x 0.49 14.2 0.6 1.3 14.4 295 8 7 x 0.49 14.2 0.6 1.3 18.8 510 CPC-T1308-JU14G 12 7 x 0.49 14.2 0.6 1.3 21.7 710 1.3 16 7 x 0.49 14.2 0.6 1.5 25.0 930 CPC-T1316-JU14G 20 7 x 0.49 14.2 0.6 1.5 27.4 1130 24 7 x 0.49 14.2 0.6 1.7 29.6 1335 CPC-T1324-JU14G 30 7 x 0.49 14.2 0.6 2.0 34.6 1630 2 7 x 0.53 12.6 0.6 1.2 14.0 230 CPC-T1302-JU15G 4 7 x 0.53 12.6 0.6 1.3 15.9 325 8 7 x 0.53 12.6 0.6 1.3 20.8 570 CPC-T1308-JU15G 12 7 x 0.53 12.6 0.6 1.5 24.8 810 1.5 16 7 x 0.53 12.6 0.6 1.5 27.9 1120 CPC-T1316-JU15G 20 7 x 0.53 12.6 0.6 1.7 30.7 1280 24 7 x 0.53 12.6 0.6 2.0 33.1 1515 CPC-T1324-JU15G 30 7 x 0.53 12.6 0.6 2.2 37.3 1960 • The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 9 PVC Insulation Multitriples, Layers, Individual and Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Wrapping: BS 5308-2 Polyester tapes

Rated Voltage: Collective Screen 300/500 V Aluminum polyester tape with tinned drain wire and wrapped by polyester tapes Conductor: Stranded annealed plain copper Sheath: Polyvinylchloride TM1 to BS 6746 colour black or Insulation: grey or blue Polyvinylchloride TI1 to BS 6746

Minimum bending radius: UIC Elsewedy Instrumentation Cables 300 V Assembly: 7.5 x d (d= overall diameter) Cores twisted to form triples, triples screened by aluminum polyester tapes, screened triples Temperature rating: twisted in concentric layers, and wrapped by +5oC up to + 50oC during operation polyester tapes

Colour code: Packing: Black / White / Red, continuously numbered, On non-returnable wooden drums or identification tapes numbered

Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size triples No.x dia. Res. At thickness thickness diameter weight 20oC No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 2 7 x 0.3 39.2 0.6 1.0 11.7 150 CPC-T1302-JU05B 4 7 x 0.3 39.2 0.6 1.2 13.2 205 CPC-T1304-JU05B 8 7 x 0.3 39.2 0.6 1.3 17.0 335 CPC-T1308-JU05B 12 7 x 0.3 39.2 0.6 1.3 19.6 450 CPC-T1312-JU05B 0.5 16 7 x 0.3 39.2 0.6 1.3 22.0 575 CPC-T1316-JU05B 20 7 x 0.3 39.2 0.6 1.5 24.7 710 CPC-T1320-JU05B 24 7 x 0.3 39.2 0.6 1.5 26.6 835 CPC-T1324-JU05B 30 7 x 0.3 39.2 0.6 1.7 29.2 1130 CPC-T1330-JU05B 2 7 x 0.37 24.6 0.6 1.0 12.5 165 CPC-T1302-JU08B 4 7 x 0.37 24.6 0.6 1.2 14.1 235 CPC-T1304-JU08B 8 7 x 0.37 24.6 0.6 1.3 18.3 395 CPC-T1308-JU08B 12 7 x 0.37 24.6 0.6 1.3 21.1 550 CPC-T1312-JU08B 0.75 16 7 x 0.37 24.6 0.6 1.5 24.2 720 CPC-T1316-JU08B 20 7 x 0.37 24.6 0.6 1.7 26.7 875 CPC-T1320-JU08B 24 7 x 0.37 24.6 0.6 1.7 28.8 1030 CPC-T1324-JU08B 30 7 x 0.37 24.6 0.6 2.0 32.4 1325 CPC-T1330-JU08B

A 10 PVC Insulation Multitriples, Layers, Individual and Collective Screen

Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size No.x dia. Res. At Triples 20oC thickness thickness diameter weight 2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.2 13.7 195 CPC-T1302-SU12B

4 7 x 0.43 18.4 0.6 1.3 15.5 285 CPC-T1304-SU12B

8 7 x 0.43 18.4 0.6 1.3 20.3 480 CPC-T1308-SU12B

12 7 x 0.43 18.4 0.6 1.5 23.5 665 CPC-T1312-SU12B 1.0 16 7 x 0.43 18.4 0.6 1.5 27.1 880 CPC-T1316-SU12B

20 7 x 0.43 18.4 0.6 1.7 29.8 1060 CPC-T1320-SU12B

24 7 x 0.43 18.4 0.6 1.7 32.2 1250 CPC-T1324-SU12B

30 7 x 0.43 18.4 0.6 2.0 35.3 1530 CPC-T1330-SU14B

2 7 x 0.49 14.2 0.6 1.3 14.4 230 CPC-T1302-SU14B

4 7 x 0.49 14.2 0.6 1.3 16.4 330 CPC-T1304-SU14B

8 7 x 0.49 14.2 0.6 1.3 21.6 565 CPC-T1308-SU14B

12 7 x 0.49 14.2 0.6 1.5 25.6 810 CPC-T1312-SU14B 1.3 16 7 x 0.49 14.2 0.6 1.7 28.9 1050 CPC-T1316-SU14B

20 7 x 0.49 14.2 0.6 1.7 31.8 1270 CPC-T1320-SU14B

24 7 x 0.49 14.2 0.6 2.0 35.4 1525 CPC-T1324-SU14B

30 7 x 0.49 14.2 0.6 2.2 37.2 1730 CPC-T1330-SU14B

2 7 x 0.53 12.6 0.6 1.3 15.2 265 CPC-T1302-SU15B

4 7 x 0.53 12.6 0.6 1.3 17.3 365 CPC-T1304-SU15B

8 7 x 0.53 12.6 0.6 1.3 22.9 610 CPC-T1308-SU15B

12 7 x 0.53 12.6 0.6 1.5 27.2 935 CPC-T1312-SU15B 1.5 16 7 x 0.53 12.6 0.6 1.7 30.7 1180 CPC-T1316-SU15B

20 7 x 0.53 12.6 0.6 2.0 33.8 1430 CPC-T1320-SU15B

24 7 x 0.53 12.6 0.6 2.2 37.0 1710 CPC-T1324-SU15B

30 7 x 0.53 12.6 0.6 2.2 40.6 2200 CPC-T1330-SU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 11 PVC Insulation Single Pair, Collective Screen , Galvanized Steel Wire Armour Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes, where mechanical damages are expected to occur.

Engineering Specification:

Standard: Screen: BS 5308-2 Collective screen of aluminium polyester tapes with tinned drain wire and wrapped by polyester tapes Rated Voltage: Bedding: 300/500 V Polyvinylchloride Conductor: Armouring; Stranded annealed plain copper Galvanized steel wire armour to BS 1442 Sheath:

Insulation: Polyvinylchloride TM1 to BS 6746 colour black or blue UIC Elsewedy Instrumentation Cables 300 V Polyvinylchloride TI1 to BS 6746 Minimum bending radius: Assembly: 10 x d (d= overall diameter) cores twisted to form a pair and screened by Temperature rating: Aluminum Polyester tape with tinned drain +5oC up to + 50oC during operation wire and wrapped by polyester tapes Packing: Colour code: On non-returnable wooden drums Black / White

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor Max. steel wire of No.x insulation sheath overall net UIC – code size DC Res. diameter pairs dia. thickness thickness diameter weight At 20oC No. x Ohm mm2 No. mm mm mm mm Kg/Km - mm /Km 0.5 1 7 x 0.3 39.2 0.6 0.8 1.3 10.7 219 CPC-T1201-JM05B

0.75 1 7 x 0.37 24.6 0.6 0.8 1.3 11.0 240 CPC-T1201-JM08B

1.0 1 7 x 0.43 18.4 0.6 0.8 1.3 11.4 255 CPC-T1201-JM12B

1.3 1 7 x 0.49 14.2 0.6 0.8 1.4 11.8 275 CPC-T1201-JM14B

1.5 1 7 x 0.53 12.6 0.6 0.8 1.4 12.6 300 CPC-T1201-JM15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 12 PVC Insulation Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes, where mechanical damages are expected to occur.

Engineering Specification:

Standard: BS 5308-2 Screen: Collective screen of aluminium polyester tape with Rated Voltage: tinned drain wire and wrapped by polester tapes 300/500 V Bedding: Polyvinylchloride Conductor: Stranded annealed plain copper Armouring; Galvanized steel wire armour to BS 1442 Insulation:

Polyvinylchloride TI1 to BS 6746 Sheath: UIC Elsewedy Instrumentation Cables 300 V Polyvinylchloride TM1 to BS 6746 colour black or blue Assembly: Cores twisted to form a pairs, pairs twisted Minimum bending radius: in concentric layers and wrapped by 10 x d (d= overall diameter) polyester tapes Temperature rating: Colour code: +5oC up to + 50oC during operation Black / White continuously numbered, or identification tapes Packing: numbered On non-returnable wooden drums

Technical Information

Conductor Number Nominal Nominal Approximate Approximate Conductor steel wire of Max. insulation sheath overall net UIC – code size No.x DC diameter pairs thickness thickness diameter weight dia. Res. At 20oC

2 No. x Ohm mm No. mm /Km mm mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 0.8 1.4 13.5 344 CPC-T1202-JM05B 4 7 x 0.3 39.2 0.6 0.8 1.4 14.6 395 CPC-T1204-JM05B 8 7 x 0.3 39.2 0.6 1.25 1.5 18.7 665 CPC-T1208-JM05B 0.5 12 7 x 0.3 39.2 0.6 1.25 1.6 20.7 800 CPC-T1212-JM05B 16 7 x 0.3 39.2 0.6 1.25 1.6 22.4 920 CPC-T1216-JM05B 20 7 x 0.3 39.2 0.6 1.6 1.7 25.3 1220 CPC-T1220-JM05B 24 7 x 0.3 39.2 0.6 1.6 1.7 27.2 1370 CPC-T1224-JM05B 30 7 x 0.3 39.2 0.6 1.6 1.9 30.1 1710 CPC-T1230-JM05B 2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 395 CPC-T1202-JM08B 4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 440 CPC-T1204-JM08B 8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 760 CPC-T1208-JM08B 12 7 x 0.37 24.6 0.6 1.25 1.7 24.9 905 CPC-T1212-JM08B 0.75 16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1240 CPC-T1216-JM08B 20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1390 CPC-T1220-JM08B 24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1580 CPC-T1224-JM08B 30 7 x 0.37 24.6 0.6 1.6 2.0 36.1 1800 CPC-T1230-JM08B • The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 13 PVC Insulation Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor Max. steel wire of insulation sheath overall net UIC – code size No.x DC diameter pairs dia. Res. At thickness thickness diameter weight 20oC No. x Ohm mm2 No. mm mm mm mm Kg/Km - mm /Km 2 7 x 0.43 18.4 0.6 0.8 1.5 15.2 440 CPC-T1202-JM12B 4 7 x 0.43 18.4 0.6 0.8 1.5 16.4 490 CPC-T1204-JM12B 8 7 x 0.43 18.4 0.6 1.25 1.6 21.1 840 CPC-T1208-JM12B

1.0 12 7 x 0.43 18.4 0.6 1.6 1.7 24.4 1200 CPC-T1212-JM12B 16 7 x 0.43 18.4 0.6 1.6 1.7 26.4 1380 CPC-T1216-JM12B 20 7 x 0.43 18.4 0.6 1.6 1.8 28.8 1580 CPC-T1220-JM12B 24 7 x 0.43 18.4 0.6 1.6 1.9 31.8 1850 CPC-T1224-JM12B 30 7 x 0.43 18.4 0.6 2.0 2.0 35.0 2470 CPC-T1230-JM12B 2 7 x 0.49 14.2 0.6 0.8 1.5 15.6 460 CPC-T1202-JM14B 4 7 x 0.49 14.2 0.6 1.25 1.5 18.1 630 CPC-T1204-JM14B 8 7 x 0.49 14.2 0.6 1.25 1.6 22.2 900 CPC-T1208-JM14B 12 7 x 0.49 14.2 0.6 1.6 1.7 25.3 1290 CPC-T1212-JM14B 1.3 16 7 x 0.49 14.2 0.6 1.6 1.8 28.1 1510 CPC-T1216-JM14B 20 7 x 0.49 14.2 0.6 1.6 1.8 30.4 1660 CPC-T1220-JM14B 24 7 x 0.49 14.2 0.6 1.6 1.9 32.5 1970 CPC-T1224-JM14B 30 7 x 0.49 14.2 0.6 2.0 2.0 35.9 2420 CPC-T1230-JM14B 2 7 x 0.53 12.6 0.6 1.25 1.6 18.2 620 CPC-T1202-JM15B 4 7 x 0.53 12.6 0.6 1.25 1.6 19.7 745 CPC-T1204-JM15B 8 7 x 0.53 12.6 0.6 1.6 1.7 25.2 1230 CPC-T1208-JM15B 12 7 x 0.53 12.6 0.6 1.6 1.8 28.1 1520 CPC-T1212-JM15B 1.5 16 7 x 0.53 12.6 0.6 1.6 1.9 31.3 1865 CPC-T1216-JM15B 20 7 x 0.53 12.6 0.6 1.6 1.9 34.1 2140 CPC-T1220-JM15B 24 7 x 0.53 12.6 0.6 2.0 2.0 38.3 2740 CPC-T1224-JM15B 30 7 x 0.53 12.6 0.6 2.0 2.0 41.6 3340 CPC-T1230-JM15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 14 PVC Insulation Individual and Collective Screen, Galvanized Steel Wire Armour Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes, where mechanical damages are expected to occur.

Engineering Specification:

Standard: Screen: BS 5308-2 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300/500 V Bedding: Polyvinylchloride Conductor: Stranded annealed plain copper Armouring; Galvanized steel wire armour to BS 1442 Insulation: Polyvinylchloride TI1 to BS 6746 Sheath:

Polyvinylchloride TM1 to BS 6746 colour black or blue Cables 300 V UIC Elsewedy Instrumentation Assembly: Cores twisted to form a pairs, pairs screened Minimum bending radius: by aluminium polyester tapes, screened pairs 10 x d (d= overall diameter) twisted in concentric layers and wrapped by polyester tapes Temperature rating: +5oC up to + 50oC during operation Colour code: Black / White continuously numbered, or Packing: identification tapes numbered On non-returnable wooden drums

Technical Information

Conductor Number Nominal Nominal Approximate Approximate Conductor Max. DC steel wire of No.x insulation sheath overall net UIC – code size Res. At diameter pairs dia. thickness thickness diameter weight 20oC No. x Ohm mm2 No. mm mm mm mm Kg/Km - mm /Km 2 7 x 0.3 39.2 0.6 0.8 1.4 14.7 390 CPC-T1202-SM05B 4 7 x 0.3 39.2 0.6 0.8 1.5 15.9 450 CPC-T1204-SM05B 8 7 x 0.3 39.2 0.6 1.25 1.6 20.4 760 CPC-T1208-SM05B

0.5 12 7 x 0.3 39.2 0.6 1.25 1.6 22.7 940 CPC-T1212-SM05B 16 7 x 0.3 39.2 0.6 1.6 1.7 25.5 1260 CPC-T1216-SM05B 20 7 x 0.3 39.2 0.6 1.6 1.8 27.8 1420 CPC-T1220-SM05B 24 7 x 0.3 39.2 0.6 1.6 1.9 30.7 1660 CPC-T1224-SM05B 30 7 x 0.3 39.2 0.6 1.6 1.9 33.0 2015 CPC-T1230-SM08B 2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 440 CPC-T1202-SM08B 4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 490 CPC-T1204-SM08B 8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 850 CPC-T1208-SM08B 12 7 x 0.37 24.6 0.6 1.6 1.7 24.9 1210 CPC-T1212-SM08B 0.75 16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1390 CPC-T1216-SM08B 20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1620 CPC-T1220-SM08B 24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1880 CPC-T1224-SM08B 30 7 x 0.37 24.6 0.6 2.0 2.0 36.1 2590 CPC-T1230-SM08B

A 15 PVC Insulation Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor steel wire of Max. DC insulation sheath overall net UIC – code size diameter pairs No.x dia. Res. At thickness thickness diameter weight 20oC

2 Ohm mm No. No. x mm /Km mm mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.25 1.5 17.2 570 CPC-T1202-SM12B 4 7 x 0.43 18.4 0.6 1.25 1.5 18.6 660 CPC-T1204-SM12B 8 7 x 0.43 18.4 0.6 1.25 1.7 23.1 960 CPC-T1208-SM12B

1.0 12 7 x 0.43 18.4 0.6 1.6 1.7 26.3 1335 CPC-T1212-SM12B 16 7 x 0.43 18.4 0.6 1.6 1.8 28.7 1570 CPC-T1216-SM12B 20 7 x 0.43 18.4 0.6 1.6 1.9 32.0 1870 CPC-T1220-SM12B 24 7 x 0.43 18.4 0.6 1.6 1.9 34.6 2120 CPC-T1224-SM12B 30 7 x 0.43 18.4 0.6 2.0 2.1 38.3 2830 CPC-T1230-SM12B 2 7 x 0.49 14.2 0.6 1.25 1.5 18.2 680 CPC-T1202-SM14B 4 7 x 0.49 14.2 0.6 1.25 1.6 20.3 850 CPC-T1204-SM14B 8 7 x 0.49 14.2 0.6 1.6 1.7 26.4 1350 CPC-T1208-SM14B 12 7 x 0.49 14.2 0.6 1.6 1.8 29.5 1560 CPC-T1212-SM14B 1.3 16 7 x 0.49 14.2 0.6 1.6 1.9 32.0 1860 CPC-T1216-SM14B 20 7 x 0.49 14.2 0.6 2.0 2.0 36.6 2300 CPC-T1220-SM14B 24 7 x 0.49 14.2 0.6 2.0 2.1 39.3 3200 CPC-T1224-SM14B 30 7 x 0.49 14.2 0.6 2.0 2.2 44.2 3900 CPC-T1230-SM14B 2 7 x 0.53 12.6 0.6 1.25 1.7 22.8 1000 CPC-T1202-SM15B 4 7 x 0.53 12.6 0.6 1.25 1.7 24.1 1130 CPC-T1204-SM15B 8 7 x 0.53 12.6 0.6 1.6 1.8 30.4 1690 CPC-T1208-SM15B 12 7 x 0.53 12.6 0.6 1.6 1.9 34.1 2130 CPC-T1212-SM15B 1.5 16 7 x 0.53 12.6 0.6 1.6 2.0 38.7 2280 CPC-T1216-SM15B 20 7 x 0.53 12.6 0.6 2.0 2.2 43.3 3430 CPC-T1220-SM15B 24 7 x 0.53 12.6 0.6 2.0 2.3 48.5 4420 CPC-T1224-SM15B 30 7 x 0.53 12.6 0.6 2.5 2.5 52.8 5390 CPC-T1230-SM15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 16 PE Insulation Multipairs, Twisted in Bundles, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Wrapping: BS 5308-2 Polyester tapes

Rated Voltage: Collective Screen: 300/500 V Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes Conductor: Stranded annealed plain copper Sheath: Polyvinylchloride TM1 to BS 6746 colour Insulation: black or blue

Polyethelene type 03 to BS 6234 V 225 Cables Instrumentation Elsewedy UIC Minimum bending radius: Assembly: 7.5 x d (d= overall diameter) Cores twisted to form pairs, 4 pairs twisted to form a bundle , bundles Temperature rating: twisted in concentric layers, 2 pairs +5oC up to + 50oC during operation twisted as star quad Packing: Colour code: On non-returnable wooden drums One Pair : Blue / Red Two Pairs : Grey / Yellow Three Pairs : Green / Brown Four Pairs : White / Black Bundles are identified by coloured polyester tapes Technical Information Conductor Nominal Nominal Approximate Conductor Number Max. Approximate Insulation Sheath Overall Cable Code Size of Pairs No. x DC Net Weight dia Res. Thickness Thickness Diameter At 20º mm2 No. x Ohm/ No. mm Km mm mm mm Kg/Km - 2 7 X 0.3 39.2 0.6 1.0 6.9 65 CGC-T1202-JU05BQ 4 7 X 0.3 39.2 0.6 1.0 9.1 85 CGC-T1204-JU05BQ 8 7 X 0.3 39.2 0.6 1.0 11.1 140 CGC-T1208-JU05BQ

0.5 12 7 X 0.3 39.2 0.6 1.2 13.4 195 CGC-T1212-JU05BQ 16 7 X 0.3 39.2 0.6 1.2 15.1 260 CGC-T1216-JU05BQ 20 7 X 0.3 39.2 0.6 1.2 16.5 340 CGC-T1220-JU05BQ 24 7 X 0.3 39.2 0.6 1.4 18.3 430 CGC-T1224-JU05BQ 2 7 X 0.43 18.4 0.6 1.0 8.9 85 CGC-T1202-JU12BQ 4 7 X 0.43 18.4 0.6 1.0 12.0 140 CGC-T1204-JU12BQ 8 7 X 0.43 18.4 0.6 1.2 16.0 165 CGC-T1208-JU12BQ

1.0 12 7 X 0.43 18.4 0.6 1.4 20.0 390 CGC-T1212-JU12BQ 16 7 X 0.43 18.4 0.6 1.4 22.0 500 CGC-T1216-JU12BQ 20 7 X 0.43 18.4 0.6 1.4 24.0 640 CGC-T1220-JU12BQ 24 7 X 0.43 18.4 0.6 1.6 26.0 780 CGC-T1224-JU12BQ • The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 17 PE Insulation Single Pair or Triple, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Wrapping: BS 5308-2 Polyester tapes

Rated Voltage: Collective Screen: 300/500 V Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes Conductor: Stranded annealed plain copper Sheath:

Polyvinylchloride TM1 to BS 6746 colour V 300 Cables Instrumentation Elsewedy UIC Insulation: black or blue Polyethelene type 03 to BS 6234 Minimum bending radius: Assembly: 7.5 x d (d= overall diameter) Cores twisted to form a pair or triple and wrapped by polyester tape Temperature rating: +5oC up to +50oC during operation Colour code: Pair: Black / White Packing: Triple: Black / White / Red On non-returnable wooden drums

Technical Information

Conductor Nominal Nominal Approximate Approximate Cable Size Max. DC Res. At insulation sheath overall net UIC – code No.x dia. 20oC thickness thickness diameter weight mm2 No. x mm Ohm /Km mm mm mm Kg/Km - 1 x 2 x 0.5 7 x 0.3 39.2 0.6 0.8 5.3 40 CGC-T1201-JU05B 1 x 3 x 0.5 7 x 0.3 39.2 0.6 0.8 5.6 50 CGC-T1301- JU05B 1 x 2 x 0.75 7 x 0.37 24.6 0.6 0.8 6.4 56 CGC-T1201- JU08B 1 x 3 x 0.75 7 x 0.37 24.6 0.6 0.8 6.7 65 CGC-T1301- JU08B 1 x 2 x 1.0 7 x 0.43 18.4 0.6 0.8 6.8 66 CGC-T1201- JU12B 1 x 3 x 1.0 7 x 0.43 18.4 0.6 0.8 7.1 75 CGC-T1301- JU12B 1 x 2 x 1.3 7 x 0.49 14.2 0.6 0.8 7.1 75 CGC-T1201- JU14B 1 x 3 x 1.3 7 x 0.49 14.2 0.6 0.8 7.4 85 CGC-T1301- JU14B 1 x 2 x 1.5 7 x 0.53 12.6 0.6 0.8 7.6 85 CGC-T1201- JU15B 1 x 3 x 1.5 7 x 0.53 12.6 0.6 0.8 8.0 104 CGC-T1301- JU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 18 PE Insulation Multipairs, Layers, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300/500 V Sheath: Polyvinylchloride TM1 to BS 6746 colour black or blue Conductor: Stranded annealed plain copper Minimum bending radius: 7.5 x d (d= overall diameter)

Insulation: V 300 Cables Instrumentation Elsewedy UIC Polyethelene TI1 to BS 6746 Temperature rating: +5oC up to + 50oC during operation Assembly: Cores twisted to form a pairs,pairs Packing: twisted in concentric layers and On non-returnable wooden drums wrapped by polyester tapes

Colour code: Black / White continuously numbered, or identification tapes numbered

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC Res. insulation sheath overall net UIC – code size No.x dia. pairs At 20oC thickness thickness diameter weight

mm2 No. x No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.0 9.3 98 CGC-T1202-JU05B 4 7 x 0.3 39.2 0.6 1.0 10.0 112 CGC-T1204-JU05B 8 7 x 0.3 39.2 0.6 1.2 13.2 189 CGC-T1208-JU05B

0.5 12 7 x 0.3 39.2 0.6 1.2 15.0 252 CGC-T1212-JU05B 16 7 x 0.3 39.2 0.6 1.2 16.7 318 CGC-T1216-JU05B 20 7 x 0.3 39.2 0.6 1.3 18.7 387 CGC-T1220-JU05B 24 7 x 0.3 39.2 0.6 1.3 20.6 452 CGC-T1224-JU05B 30 7 x 0.3 39.2 0.6 1.5 23.3 640 CGC-T1230-JU08B 2 7 x 0.37 24.6 0.6 1.0 10.1 120 CGC-T1202-JU08B 4 7 x 0.37 24.6 0.6 1.0 10.8 134 CGC-T1204-JU08B 8 7 x 0.37 24.6 0.6 1.2 14.3 232 CGC-T1208-JU08B 12 7 x 0.37 24.6 0.6 1.2 16.3 315 CGC-T1212-JU08B 0.75 16 7 x 0.37 24.6 0.6 1.3 18.3 410 CGC-T1216-JU08B 20 7 x 0.37 24.6 0.6 1.3 20.3 490 CGC-T1220-JU08B 24 7 x 0.37 24.6 0.6 1.3 22.5 575 CGC-T1224-JU08B 30 7 x 0.37 24.6 0.6 1.5 24.3 683 CGC-T1230-JU08B

A 19 PE Insulation Multipairs, Layers, Collective Screen

Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size pairs No.x dia. Res. At thickness thickness diameter weight 20oC mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -

2 7 x 0.43 18.4 0.6 1.0 10.8 138 CGC-T1202-JU12B

4 7 x 0.43 18.4 0.6 1.0 11.6 160 CGC-T1204-JU12B

8 7 x 0.43 18.4 0.6 1.2 15.4 282 CGC-T1208- JU12B

1.0 12 7 x 0.43 18.4 0.6 1.3 17.8 396 CGC-T1212-JU12B 16 7 x 0.43 18.4 0.6 1.3 19.8 504 CGC-T1216- JU12B

20 7 x 0.43 18.4 0.6 1.3 22.0 608 CGC-T1220-JU12B

24 7 x 0.43 18.4 0.6 1.5 24.8 745 CGC-T1224-JU12B

30 7 x 0.43 18.4 0.6 1.7 27.5 1005 CGC-T1230-JU12B

2 7 x 0.49 14.2 0.6 1.0 11.7 152 CGC-T1202-JU14B

4 7 x 0.49 14.2 0.6 1.2 13.3 215 CGC-T1204-JU14B

8 7 x 0.49 14.2 0.6 1.3 16.5 360 CGC-T1208- JU14B

12 7 x 0.49 14.2 0.6 1.3 19.3 385 CGC-T1212-JU14B 1.3 16 7 x 0.49 14.2 0.6 1.3 21.7 575 CGC-T1216-JU14B

20 7 x 0.49 14.2 0.6 1.5 24.2 780 CGC-T1220-JU14B

24 7 x 0.49 14.2 0.6 1.7 26.3 930 CGC-T1224-JU14B

30 7 x 0.49 14.2 0.6 1.7 31.0 1280 CGC-T1230-JU14B

2 7 x 0.53 12.6 0.6 1.2 12.9 194 CGC-T1202-JU15B

4 7 x 0.53 12.6 0.6 1.2 14.1 233 CGC-T1204-JU15B

8 7 x 0.53 12.6 0.6 1.3 18.6 405 CGC-T1208-JU15B

12 7 x 0.53 12.6 0.6 1.3 21.3 564 CGC-T1212-JU15B 1.5 16 7 x 0.53 12.6 0.6 1.5 24.3 797 CGC-T1216-JU15B

20 7 x 0.53 12.6 0.6 1.5 27.1 912 CGC-T1220-JU15B

24 7 x 0.53 12.6 0.6 1.7 30.3 1104 CGC-T1224-JU15B

30 7 x 0.53 12.6 0.6 2.0 33.7 1507 CGC-T1230-JU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 20 PE Insulation Multipairs, Layers, Individual and Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of Aluminum Polyester tapes with tinned drain wire and wrapped by polyester Rated Voltage: tapes 300/500 V Sheath: Conductor: Polyvinylchloride TM1 to BS 6746 colour black or blue Stranded plain annealed copper Minimum bending radius: Insulation: 7.5 x d (d= overall diameter) Polyethelene 03 to BS 6234 V 300 Cables Instrumentation Elsewedy UIC Temperature rating: Assembly: +5oC up to + 50oC during operation Cores twisted to form a pairs, pairs screened by Aluminium Polyester tapes, Screened pairs Packing: twisted in concentric layers and wrapped by On non-returnable wooden drums polyester tapes

Colour code: Black / White continuously numbered, or identification tapes numbered Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. pairs 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 2 7 x 0.3 39.2 0.6 1.0 10.3 118 CGC-T1202-SU05B 4 7 x 0.3 39.2 0.6 1.0 11.1 136 CGC-T1204-SU05B 8 7 x 0.3 39.2 0.6 1.2 14.7 234 CGC-T1208-SU05B 0.5 12 7 x 0.3 39.2 0.6 1.3 17.0 325 CGC-T1212-SU05B 16 7 x 0.3 39.2 0.6 1.3 18.9 413 CGC-T1216-SU05B 20 7 x 0.3 39.2 0.6 1.3 21.0 495 CGC-T1220-SU05B 24 7 x 0.3 39.2 0.6 1.5 23.7 606 CGC-T1224-SU05B 30 7 x 0.3 39.2 0.6 1.5 26.3 822 CGC-T1230-SU08B 2 7 x 0.37 24.6 0.6 1.0 11.2 145 CGC-T1202-SU08B 4 7 x 0.37 24.6 0.6 1.0 11.9 159 CGC-T1204-SU08B 8 7 x 0.37 24.6 0.6 1.2 15.8 280 CGC-T1208-SU08B 12 7 x 0.37 24.6 0.6 1.3 18.3 390 CGC-T1212-SU08B 0.75 16 7 x 0.37 24.6 0.6 1.3 20.4 500 CGC-T1216-SU08B 20 7 x 0.37 24.6 0.6 1.3 22.8 602 CGC-T1220-SU08B 24 7 x 0.37 24.6 0.6 1.5 25.7 736 CGC-T1224-SU08B 30 7 x 0.37 24.6 0.6 1.7 26.4 864 CGC-T1230-SU08B

A 21 PE Insulation Multipairs, Layers, Individual and Collective Screen Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size pairs No.x dia. Res. At thickness thickness diameter weight 20oC mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.2 12.2 170 CGC-T1202-SU12B 4 7 x 0.43 18.4 0.6 1.2 13.1 195 CGC-T1204- SU12B 8 7 x 0.43 18.4 0.6 1.3 17.2 340 CGC-T1208- SU12B 1.0 12 7 x 0.43 18.4 0.6 1.3 19.7 465 CGC-T1212- SU12B 16 7 x 0.43 18.4 0.6 1.3 21.9 600 CGC-T1216- SU12B 20 7 x 0.43 18.4 0.6 1.5 25.0 645 CGC-T1220- SU12B 24 7 x 0.43 18.4 0.6 1.5 27.6 880 CGC-T1224- SU12B 30 7 x 0.43 18.4 0.6 1.7 30.5 1195 CGC-T1230- SU12B 2 7 x 0.49 14.2 0.6 1.2 12.8 180 CGC-T1202- SU14B 4 7 x 0.49 14.2 0.6 1.3 14.0 230 CGC-T1204- SU14B 8 7 x 0.49 14.2 0.6 1.3 18.2 410 CGC-T1208- SU14B 12 7 x 0.49 14.2 0.6 1.3 20.3 590 CGC-T1212- SU14B 1.3 16 7 x 0.49 14.2 0.6 1.5 23.3 760 CGC-T1216- SU14B 20 7 x 0.49 14.2 0.6 1.5 27.0 850 CGC-T1220- SU14B 24 7 x 0.49 14.2 0.6 1.7 31.2 1065 CGC-T1224- SU14B 30 7 x 0.49 14.2 0.6 2.0 34.5 1400 CGC-T1230- SU14B 2 7 x 0.53 12.6 0.6 1.2 14.1 220 CGC-T1202- SU15B 4 7 x 0.53 12.6 0.6 1.2 15.4 263 CGC-T1204- SU15B 8 7 x 0.53 12.6 0.6 1.3 20.3 460 CGC-T1208- SU15B 12 7 x 0.53 12.6 0.6 1.5 24.0 670 CGC-T1212- SU15B 1.5 16 7 x 0.53 12.6 0.6 1.5 26.7 865 CGC-T1216- SU15B 20 7 x 0.53 12.6 0.6 1.7 30.2 1070 CGC-T1220- SU15B 24 7 x 0.53 12.6 0.6 2.0 34.0 1300 CGC-T1224- SU15B 30 7 x 0.53 12.6 0.6 2.2 37.4 1750 CGC-T1230- SU15B • The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 22 PE Insulation Multitriples, Layers, Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped Rated Voltage: by polyester tapes 300/500 V Sheath: Conductor: Polyvinylchloride TM1 to BS 6746 colour Stranded plain annealed copper black or blue

Insulation: Minimum bending radius: Polyethelene 03 to BS 6234 7.5 x d (d= overall diameter)

Assembly: Temperature rating: Cores twisted to form a triples, triples twisted in +5oC up to + 50oC during operation concentric layers and U I C Elsewedy nstrumentation Cables 300 V wrapped by polyester tapes Packing: On non-returnable wooden drums Colour code: Black / White/ Red continuously numbered, or identification tapes numbered Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of insulation sheath overall net UIC – code size No.x Max. DC Res. Triples dia. At 20oC thickness thickness diameter weight No. x mm2 No. Ohm/Km mm mm mm Kg/Km - mm 2 7 x 0.3 39.2 0.6 1.0 10.1 115 CGC-T1302-JU05B 4 7 x 0.3 39.2 0.6 1.0 10.8 135 CGC-T1304-JU05B 8 7 x 0.3 39.2 0.6 1.2 14.6 230 CGC-T1308-JU05B

0.5 12 7 x 0.3 39.2 0.6 1.3 16.5 330 CGC-T1312-JU05B 16 7 x 0.3 39.2 0.6 1.3 18.7 420 CGC-T1316-JU05B 20 7 x 0.3 39.2 0.6 1.3 21.2 535 CGC-T1320-JU05B 24 7 x 0.3 39.2 0.6 1.5 24.0 635 CGC-T1324-JU05B 30 7 x 0.3 39.2 0.6 1.5 27.7 960 CGC-T1330-JU08B 2 7 x 0.37 24.6 0.6 1.0 10.9 130 CGC-T1302-JU08B 4 7 x 0.37 24.6 0.6 1.0 11.8 175 CGC-T1304-JU08B 8 7 x 0.37 24.6 0.6 1.3 15.9 355 CGC-T1308-JU08B 12 7 x 0.37 24.6 0.6 1.3 17.9 415 CGC-T1312-JU08B 0.75 16 7 x 0.37 24.6 0.6 1.3 20.2 515 CGC-T1316-JU08B 20 7 x 0.37 24.6 0.6 1.5 23.8 645 CGC-T1320-JU08B 24 7 x 0.37 24.6 0.6 1.5 26.0 955 CGC-T1324-JU08B 30 7 x 0.37 24.6 0.6 1.7 30.0 1150 CGC-T1330-JU08B

A 23 PE Insulation Multitriples, Layers, Collective Screen Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size No.x dia. Res. At Triples 20oC thickness thickness diameter weight mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.2 12.1 160 CGC-T1302-JU12B 4 7 x 0.43 18.4 0.6 1.2 13.6 240 CGC-T1304- JU12B 8 7 x 0.43 18.4 0.6 1.3 17.6 420 CGC-T1308- JU12B

1.0 12 7 x 0.43 18.4 0.6 1.3 20.3 570 CGC-T1312- JU12B 16 7 x 0.43 18.4 0.6 1.3 22.8 730 CGC-T1316- JU12B 20 7 x 0.43 18.4 0.6 1.5 25.6 900 CGC-T1320- JU12B 24 7 x 0.43 18.4 0.6 1.5 27.6 1050 CGC-T1324- JU12B 30 7 x 0.43 18.4 0.6 1.7 33.2 1295 CGC-T1330- JU12B 2 7 x 0.49 14.2 0.6 1.2 12.8 190 CGC-T1302- JU14B 4 7 x 0.49 14.2 0.6 1.3 14.4 275 CGC-T1304- JU14B 8 7 x 0.49 14.2 0.6 1.3 18.8 485 CGC-T1308- JU14B 12 7 x 0.49 14.2 0.6 1.3 21.7 685 CGC-T1312- JU14B 1.3 16 7 x 0.49 14.2 0.6 1.5 25.0 910 CGC-T1316- JU14B 20 7 x 0.49 14.2 0.6 1.5 27.4 1100 CGC-T1320- JU14B 24 7 x 0.49 14.2 0.6 1.7 29.6 1300 CGC-T1324- JU14B 30 7 x 0.49 14.2 0.6 2.0 35.6 1590 CGC-T1330- JU14B 2 7 x 0.53 12.6 0.6 1.2 14.0 220 CGC-T1302- JU15B 4 7 x 0.53 12.6 0.6 1.3 15.9 300 CGC-T1304- JU15B 8 7 x 0.53 12.6 0.6 1.3 20.8 545 CGC-T1308- JU15B 12 7 x 0.53 12.6 0.6 1.5 24.8 785 CGC-T1312- JU15B 1.5 16 7 x 0.53 12.6 0.6 1.5 27.9 1100 CGC-T1316- JU15B 20 7 x 0.53 12.6 0.6 1.7 30.7 1250 CGC-T1320- JU15B 24 7 x 0.53 12.6 0.6 2.0 33.1 1460 CGC-T1324- JU15B 30 7 x 0.53 12.6 0.6 2.2 37.3 1920 CGC-T1330- JU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 24 PE Insulation Multitriples, Layers, Individual and Collective Screen Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes. Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300/500 V Sheath: Polyvinylchloride TM1 to BS 6746 colour black or blue Conductor: Stranded annealed plain copper Minimum bending radius: 7.5 x d (d= overall diameter) Insulation:

Polyethelene 03 to BS 6234 Temperature rating: I nstrumentation Cables 300 V U I C Elsewedy +5oC up to + 50oC during operation Assembly: Cores twisted to form triples, triples screened Packing: by aluminium by polyester tapes, screened On non-returnable wooden drums triples Twisted in concentric layers and wrapped by polyester tapes

Colour code: Black / White/ Red, continuously numbered, or identification tapes numbered Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. triples 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.0 11.7 145 CGC-T1302-SU05B 4 7 x 0.3 39.2 0.6 1.2 13.2 195 CGC-T1304-SU05B 8 7 x 0.3 39.2 0.6 1.3 17.0 320 CGC-T1308-SU05B

0.5 12 7 x 0.3 39.2 0.6 1.3 19.6 430 CGC-T1312-SU05B 16 7 x 0.3 39.2 0.6 1.3 22.0 560 CGC-T1316-SU05B 20 7 x 0.3 39.2 0.6 1.5 24.7 680 CGC-T1320-SU05B 24 7 x 0.3 39.2 0.6 1.5 26.6 800 CGC-T1324-SU05B 30 7 x 0.3 39.2 0.6 1.7 29.2 1100 CGC-T1330-SU08B 2 7 x 0.37 24.6 0.6 1.0 12.5 160 CGC-T1302-SU08B 4 7 x 0.37 24.6 0.6 1.2 14.1 220 CGC-T1304-SU08B 8 7 x 0.37 24.6 0.6 1.3 18.3 380 CGC-T1308-SU08B 12 7 x 0.37 24.6 0.6 1.3 21.1 530 CGC-T1312-SU08B 0.75 16 7 x 0.37 24.6 0.6 1.5 24.2 690 CGC-T1316-SU08B 20 7 x 0.37 24.6 0.6 1.7 26.7 845 CGC-T1320-SU08B 24 7 x 0.37 24.6 0.6 1.7 28.8 1000 CGC-T1324-SU08B 30 7 x 0.37 24.6 0.6 2.0 32.4 1300 CGC-T1330-SU08B

A 25 PE Insulation Multitriples, Layers, Individual and Collective Screen Technical Information Conductor Nominal Nominal Approximate Conductor Number Approximate Max. Insulation Sheath Overall Cable Code Size of Triples No. x DC Net Weight dia Res. Thickness Thickness Diameter At 20º No. x Ohm/ mm2 .No mm mm mm Kg/Km - mm Km 2 7 X 0.43 18.4 0.6 1.2 13.7 185 CGC-T1302-SU12B 4 7 X 0.43 18.4 0.6 1.3 15.5 270 CGC-T1304-SU12B 8 7 X 0.43 18.4 0.6 1.3 20.3 465 CGC-T1308-SU12B 12 7 X 0.43 18.4 0.6 1.3 23.5 650 CGC-T1312-SU12B 1.0 16 7 X 0.43 18.4 0.6 1.5 27.1 850 CGC-T1316-SU12B 20 7 X 0.43 18.4 0.6 1.7 29.8 1030 CGC-T1320-SU12B 24 7 X 0.43 18.4 0.6 1.7 32.2 1220 CGC-T1324-SU12B 30 7 X 0.43 18.4 0.6 2.0 35.3 1480 CGC-T1330-SU12B 2 7 X 0.49 14.2 0.6 1.3 14.4 220 CGC-T1302-SU14B 4 7 X 0.49 14.2 0.6 1.3 16.4 310 CGC-T1304-SU14B 8 7 X 0.49 14.2 0.6 1.3 21.6 540 CGC-T1308-SU14B 12 7 X 0.49 14.2 0.6 1.5 25.6 780 CGC-T1312-SU14B 1.3 16 7 X 0.49 14.2 0.6 1.7 28.9 1010 CGC-T1316-SU14B 20 7 X 0.49 14.2 0.6 1.7 31.8 1190 CGC-T1320-SU14B 24 7 X 0.49 14.2 0.6 2.0 35.4 1475 CGC-T1324-SU14B 30 7 X 0.49 14.2 0.6 2.0 37.2 1680 CGC-T1330-SU14B 2 7 X 0.53 12.6 0.6 1.3 15.2 255 CGC-T1302-SU15B 4 7 X 0.53 12.6 0.6 1.3 17.3 340 CGC-T1304-SU15B 8 7 X 0.53 12.6 0.6 1.3 22.9 570 CGC-T1308-SU15B 12 7 X 0.53 12.6 0.6 1.5 27.2 900 CGC-T1312-SU15B 1.5 16 7 X 0.53 12.6 0.6 1.7 30.7 1150 CGC-T1316-SU15B 20 7 X 0.53 12.6 0.6 2.0 33.8 1400 CGC-T1320-SU15B 24 7 X 0.53 12.6 0.6 2.2 37.0 1660 CGC-T1324-SU15B 30 7 X 0.53 12.6 0.6 2.2 40.6 2100 CGC-T1330-SU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 26 PE Insulation Single Pair, Collective Screen, Galvanized Steel Wire Armour Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes, where mechanical damages are expected to occur. Engineering Specification:

Standard: Bedding: BS 5308-1 Polyvinylchloride

Rated Voltage: Armouring: 300/500 V Galvanized steel wire armour to BS 1442

Conductor: Sheath: Stranded annealed plain copper Polyvinylchloride TM1 to BS 6746 colour black or blue

Insulation: Minimum bending radius: Polyethelene 03 to BS 6234 10 x d (d= overall diameter) U I C Elsewedy nstrumentation Cables 300 V

Assembly: Temperature rating: Cores twisted to form a pair or triple and +5oC up to + 50oC during operation screened by aluminium polyester tape with tinned drain wire and wrapped by polyester Packing: tapes On non-returnable wooden drums

Colour code: Black / White Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor Max. Steel wire of Insulation Sheath Overall Net UIC- Code Size No. x DC diameter Pairs dia Res. Thickness thickness diameter Weight At 20º No. x Ohm/ mm2 No. mm mm mm mm Kg/Km - mm Km 0.5 1 7 x 0.3 39.2 0.6 0.8 1.3 10.3 210 CGC-T1201-JM05B 0.75 1 7 x 0.37 24.6 0.6 0.8 1.3 11.0 230 CGC-T1201-JM08B 1.0 1 7 x 0.43 18.4 0.6 0.8 1.3 11.4 240 CGC-T1201-JM12B 1.3 1 7 x 0.49 14.2 0.6 0.8 1.4 11.8 260 CGC-T1201-JM14B 1.5 1 7 x 0.53 12.6 0.6 0.8 1.4 12.6 290 CGC-T1201-JM15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 27 PE Insulation Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes, where mechanical damages are expected to occur. Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by Rated Voltage: polyester tapes 300/500 V Bedding: Conductor: Polyvinylchloride Stranded annealed plain copper Armouring: Galvanized steel wire armour BS 1442 Insulation: Polyethelene 03 to BS 6234 Sheath:

Polyvinylchloride TM1 to BS 6746 colour black or blue U I C Elsewedy nstrumentation Cables 300 V Assembly: Cores twisted to form pairs, pairs twisted Minimum bending radius: in concentric layers and wrapped by 10x d (d= overall diameter) polyester tapes Temperature rating: Colour code: +5oC up to + 50oC during operation Black / White, continuously numbered, or identification tapes numbered Packing: On non-returnable wooden drums Technical Information Number Conductor Nominal Steel Nominal Approximate Approximate Conductor of Max. DC Res. insulation wire sheath overall net UIC – code size No.x dia. pairs At 20oC thickness diameter thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 0.8 1.4 13.5 330 CGC-T1202-JM05B 4 7 x 0.3 39.2 0.6 0.8 1.4 14.6 370 CGC-T1204-JM05B 8 7 x 0.3 39.2 0.6 1.25 1.5 18.7 630 CGC-T1208- JM05B

0.5 12 7 x 0.3 39.2 0.6 1.25 1.6 20.7 770 CGC-T1212- JM05B 16 7 x 0.3 39.2 0.6 1.25 1.6 22.4 880 CGC-T1216- JM05B 20 7 x 0.3 39.2 0.6 1.6 1.7 25.3 1170 CGC-T1220- JM05B 24 7 x 0.3 39.2 0.6 1.6 1.7 27.2 1340 CGC-T1224- JM05B 30 7 x 0.3 39.2 0.6 1.6 1.9 30.1 1660 CGC-T1230- JM05B 2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 370 CGC-T1202- JM08B 4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 410 CGC-T1204- JM08B 8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 720 CGC-T1208- JM08B 12 7 x 0.37 24.6 0.6 1.25 1.7 24.9 880 CGC-T1212- JM08B 0.75 16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1200 CGC-T1216- JM08B 20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1350 CGC-T1220- JM08B 24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1530 CGC-T1224- JM08B 30 7 x 0.37 24.6 0.6 1.6 2.0 36.1 1730 CGC-T1230- JM08B

A 28 PE Insulation Multipairs, Layers, Collective Screen Galvanized Steel Wire Armour

Technical Information

Conductor Number Nominal Nominal Approximate Approximate Conductor Max. Steel wire of Insulation Sheath Overall Net UIC- Code Size No. x DC diameter Pairs dia Res. Thickness thickness diameter Weight At 20º No. x Ohm/ mm2 No. mm mm mm mm Kg/Km - mm Km 2 7 X 0.43 18.4 0.6 0.8 1.5 15.2 420 CGC-T1202-JM12B 4 7 X 0.43 18.4 0.6 0.8 1.5 16.4 470 CGC-T1204-JM12B 8 7 X 0.43 18.4 0.6 1.25 1.6 21.1 820 CGC-T1208-JM12B 12 7 X 0.43 18.4 0.6 1.6 1.7 24.4 1170 CGC-T1212-JM12B 1.0 16 7 X 0.43 18.4 0.6 1.6 1.7 26.4 1350 CGC-T1216-JM12B 20 7 X 0.43 18.4 0.6 1.6 1.8 28.8 1530 CGC-T1220-JM12B 24 7 X 0.43 18.4 0.6 1.6 1.9 31.8 1760 CGC-T1224-JM12B 30 7 X 0.43 18.4 0.6 2.0 2.0 35.0 2390 CGC-T1230-JM12B 2 7 X 0.49 14.2 0.6 0.8 1.5 15.6 430 CGC-T1202-JM14B 4 7 X 0.49 14.2 0.6 1.25 1.5 18.1 600 CGC-T1204-JM14B 8 7 X 0.49 14.2 0.6 1.25 1.6 22.2 860 CGC-T1208-JM14B 12 7 X 0.49 14.2 0.6 1.6 1.7 25.3 1240 CGC-T1212-JM14B 1.3 16 7 X 0.49 14.2 0.6 1.6 1.8 28.1 1460 CGC-T1216-JM14B 20 7 X 0.49 14.2 0.6 1.6 1.8 30.4 1600 CGC-T1220-JM14B 24 7 X 0.49 14.2 0.6 1.6 1.9 32.5 1900 CGC-T1224-JM14B 30 7 X 0.49 14.2 0.6 2.0 2.0 35.9 2850 CGC-T1230-JM14B 2 7 X 0.53 12.6 0.6 1.25 1.6 18.2 600 CGC-T1202-JM15B 4 7 X 0.53 12.6 0.6 1.25 1.6 19.7 705 CGC-T1204-JM15B 8 7 X 0.53 12.6 0.6 1.6 1.7 25.2 1190 CGC-T1208-JM15B 12 7 X 0.53 12.6 0.6 1.6 1.8 28.1 1460 CGC-T1212-JM15B 1.5 16 7 X 0.53 12.6 0.6 1.6 1.9 31.3 1800 CGC-T1216-JM15B 20 7 X 0.53 12.6 0.6 1.6 1.9 34.1 2090 CGC-T1220-JM15B 24 7 X 0.53 12.6 0.6 2.0 2.0 38.3 2680 CGC-T1224-JM15B 30 7 X 0.53 12.6 0.6 2.0 2.2 41.6 3220 CGC-T1230-JM15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 29 PE Insulation Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes, where mechanical damages are expected to occur. Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes. Rated Voltage: 300/500 V Bedding: Polyvinylchloride Conductor: Stranded annealed plain copper Armouring: Galvanized steel wire armour to BS 1442 Insulation: Polyethelene 03 to BS 6234 Sheath: Polyvinylchloride TM1 to BS 6746 colour black or blue I nstrumentation Cables 300 V U I C Elsewedy Assembly: Cores twisted to form pairs, pairs screened Minimum bending radius: by aluminium polyester tapes, screened 10x d (d= overall diameter) pairs twisted in concentric layer and wrapped by polyester tapes Temperature rating: +5oC up to + 50oC during operation Colour code: Black / White, continuously numbered, or identification tapes numbered

Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor Steel wire of Max. DC insulation sheath overall net UIC – code size No.x dia. diameter pairs Res. At 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm mm Kg/Km - mm 2 7 x 0.3 39.2 0.6 0.8 1.4 14.7 315 CGC-T1202-JM05B 4 7 x 0.3 39.2 0.6 0.8 1.5 15.9 410 CGC-T1204-JM05B 8 7 x 0.3 39.2 0.6 1.25 1.6 20.4 690 CGC-T1208- JM05B

0.5 12 7 x 0.3 39.2 0.6 1.25 1.6 22.7 820 CGC-T1212- JM05B 16 7 x 0.3 39.2 0.6 1.6 1.7 25.5 1160 CGC-T1216- JM05B 20 7 x 0.3 39.2 0.6 1.6 1.8 27.8 1320 CGC-T1220- JM05B 24 7 x 0.3 39.2 0.6 1.6 1.9 30.7 1580 CGC-T1224- JM05B 30 7 x 0.3 39.2 0.6 1.6 1.9 33.0 1930 CGC-T1230- JM05B 2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 355 CGC-T1202- JM08B 4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 450 CGC-T1204- JM08B 8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 755 CGC-T1208- JM08B 12 7 x 0.37 24.6 0.6 1.6 1.7 24.9 1110 CGC-T1212- JM08B 0.75 16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1260 CGC-T1216- JM08B 20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1540 CGC-T1220- JM08B 24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1760 CGC-T1224- JM08B 30 7 x 0.37 24.6 0.6 2.0 2.0 36.1 2470 CGC-T1230- JM08B

A 30 PE Insulation Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor Steel wire of Max. DC Insulation Sheath Overall Net UIC- Code Size No. x diameter Pairs Res. At Thickness thickness diameter Weight dia 20º No. x mm2 No. Ohm/Km mm mm mm mm Kg/Km - mm 2 7 X 0.43 18.4 0.6 1.25 1.5 17.2 500 CGC-T1202-SM12B 4 7 X 0.43 18.4 0.6 1.25 1.5 18.6 610 CGC-T1204-SM12B 8 7 X 0.43 18.4 0.6 1.25 1.7 23.1 920 CGC-T1208-SM12B 12 7 X 0.43 18.4 0.6 1.6 1.7 26.3 1290 CGC-T1212-SM12B 1.0 16 7 X 0.43 18.4 0.6 1.6 1.8 28.7 1500 CGC-T1216-SM12B 20 7 X 0.43 18.4 0.6 1.6 1.9 32.0 1810 CGC-T1220-SM12B 24 7 X 0.43 18.4 0.6 1.6 1.9 34.6 2130 CGC-T1224-SM12B 30 7 X 0.43 18.4 0.6 2.0 2.1 38.3 2760 CGC-T1230-SM12B 2 7 X 0.49 14.2 0.6 1.25 1.5 18.2 620 CGC-T1202-SM14B 4 7 X 0.49 14.2 0.6 1.25 1.6 20.3 800 CGC-T1204-SM14B 8 7 X 0.49 14.2 0.6 1.6 1.7 26.4 1290 CGC-T1208-SM14B 12 7 X 0.49 14.2 0.6 1.6 1.8 29.5 1480 CGC-T1212-SM14B 1.3 16 7 X 0.49 14.2 0.6 1.6 1.9 32.0 1800 CGC-T1216-SM14B 20 7 X 0.49 14.2 0.6 2.0 2.0 36.6 2220 CGC-T1220-SM14B 24 7 X 0.49 14.2 0.6 2.0 2.1 39.3 3130 CGC-T1224-SM14B 30 7 X 0.49 14.2 0.6 2.0 2.2 44.2 3810 CGC-T1230-SM14B 2 7 X 0.53 12.6 0.6 1.25 1.7 22.8 930 CGC-T1202-SM15B 4 7 X 0.53 12.6 0.6 1.25 1.7 24.1 1070 CGC-T1204-SM15B 8 7 X 0.53 12.6 0.6 1.6 1.8 30.4 1600 CGC-T1208-SM15B 12 7 X 0.53 12.6 0.6 1.6 1.9 34.1 2030 CGC-T1212-SM15B 1.5 16 7 X 0.53 12.6 0.6 1.6 2.0 38.7 2190 CGC-T1216-SM15B 20 7 X 0.53 12.6 0.6 2.0 2.2 43.3 3320 CGC-T1220-SM15B 24 7 X 0.53 12.6 0.6 2.0 2.3 48.5 4310 CGC-T1224-SM15B 30 7 X 0.53 12.6 0.6 2.5 2.5 52.8 5280 CGC-T1230-SM15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 31 PE Insulation Multicores, Layers, Overall Screen of Tinned Copper Wire Braid Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes.

Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of tinned copper wire braid with coverage from 60% up to 80% and wrapped by Rated Voltage: polyester tapes 300/500 V Sheath: Conductor: Polyvinylchloride TM1 to BS 6746 colour black or blue Stranded annealed plain copper Minimum bending radius: Insulation: 7.5x d (d= overall diameter) Polyethelene 03 to BS 6234 Temperature rating: Assembly: +5oC up to + 50oC during operation Cores twisted in concentric layers and V 300 Cables Instrumentation Elsewedy UIC wrapped by polyester tapes Packing: On non-returnable wooden drums Colour code: Black continuously numbered

Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size Cores No. x dia. Res. At thickness thickness diameter weight 20oC mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -

2 7 x 0.43 18.1 0.6 1.2 7.2 95 CGC-T1202-OU12B 3 7 x 0.43 18.1 0.6 1.2 7.6 110 CGC-T1103- OU12B 5 7 x 0.43 18.1 0.6 1.3 10.3 150 CGC-T1105- OU12B 1.0 7 7 x 0.43 18.1 0.6 1.3 11.1 180 CGC-T1107- OU12B 12 7 x 0.43 18.1 0.6 1.4 14.2 270 CGC-T1112- OU12B 19 7 x 0.43 18.1 0.6 1.4 16.3 380 CGC-T1119- OU12B 24 7 x 0.43 18.1 0.6 1.6 19.2 465 CGC-T1124- OU12B 2 7 x 0.53 12.1 0.6 1.2 9.0 125 CGC-T1102- OU15B 3 7 x 0.53 12.1 0.6 1.2 9.4 145 CGC-T1103- OU15B 5 7 x 0.53 12.1 0.6 1.3 11.2 200 CGC-T1105- OU15B 1.5 7 7 x 0.53 12.1 0.6 1.3 12.0 240 CGC-T1107- OU15B 12 7 x 0.53 12.1 0.6 1.4 15.4 375 CGC-T1112- OU15B 19 7 x 0.53 12.1 0.6 1.5 18.0 545 CGC-T1119- OU15B 24 7 x 0.53 12.1 0.6 1.6 21.0 670 CGC-T1124- OU15B

A 32 PE Insulation Single Pair, Collective Screen of Tinned Copper Wire Braid Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes.

Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminium polyester tapes and tinned copper wire braid with coverage from 60% up Rated Voltage: to 80% and wrapped by polyester tapes 300/500 V Sheath: Conductor: Polyvinylchloride TM1 to BS 6746 colour black or blue Stranded annealed plain copper Minimum bending radius: Insulation: 7.5 x d (d= overall diameter) Polyethelene 03 to BS 6234 Temperature rating: Assembly: +5oC up to + 50oC during operation

Cores twisted to form a pair wrapped by UIC Elsewedy Fire Instrumentation Cables 300 V polyester tapes Packing: On non-returnable wooden drums Colour code: Black / White

Technical Information Conductor Nominal Nominal Approximate Conductor Approximate Max. DC Insulation Sheath Overall Cable Code Size Net Weight No. x dia Res. At Thickness Thickness Diameter 20º

2 No. x Ohm/ mm mm Km mm mm mm Kg/Km - 1 X 2 X 0.5 7 X 0.3 39.2 0.6 0.8 6.3 40 CGC-T120-OU05B

1 X 2 X 0.75 7 X 0.37 24.6 0.6 0.8 6.6 46 CGC-T120-OU08B

1 X 2 X 1.0 7 X 0.43 18.4 0.6 0.8 7.0 53 CGC-T120-OU12B

1 X 2 X 1.3 7 X 0.49 14.2 0.6 0.9 7.6 65 CGC-T120-OU14B

1 X 2 X 1.5 7 X 0.53 12.6 0.6 0.9 8.2 73 CGC-T120-OU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 33 PE Insulation Multipairs, Layers, Overall Screen of Tinned Copper Wire Braid Application: These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital signals for measurements and process control purposes.

Engineering Specification:

Standard: Screen: BS 5308-1 Collective screen of aluminum polyester tapes and tinned copper wire braid with coverage from 60% up Rated Voltage: to 80% and wrapped by polyester tapes 300/500 V Sheath: Conductor: Polyvinylchloride TM1 to BS 6746 colour black or blue Stranded annealed plain copper Minimum bending radius:

Insulation: 7.5 x d (d= overall diameter) V 300 Cables Instrumentation Elsewedy UIC Polyethelene 03 to BS 6234 Temperature rating: Assembly: +5oC up to + 50oC during operation Cores twisted to form pairs, twisted pairs in concentric layers and wrapped by polyester Packing: tapes On non-returnable wooden drums

Colour code: Black / White, continuously numbered, or identification tapes numbered

Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. pairs 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 2 7 x 0.3 39.2 0.6 1.0 9.3 95 CGC-T1202-OU05B

4 7 x 0.3 39.2 0.6 1.0 10.0 115 CGC-T1204-OU05B

6 7 x 0.3 39.2 0.6 1.2 12.3 175 CGC-T1206- OU05B 0.5 8 7 x 0.3 39.2 0.6 1.2 13.2 190 CGC-T1208- OU05B

10 7 x 0.3 39.2 0.6 1.2 14.5 220 CGC-T1210- OU05B

12 7 x 0.3 39.2 0.6 1.2 15.0 250 CGC-T1212- OU05B

2 7 x 0.37 24.6 0.6 1.0 10.1 120 CGC-T1202- OU08B

4 7 x 0.37 24.6 0.6 1.0 10.8 134 CGC-T1204- OU08B

6 7 x 0.37 24.6 0.6 1.2 13.8 220 CGC-T1206- OU08B 0.75 8 7 x 0.37 24.6 0.6 1.2 14.3 230 CGC-T1208- OU08B

10 7 x 0.37 24.6 0.6 1.2 15.8 275 CGC-T1210- OU08B

12 7 x 0.37 24.6 0.6 1.2 16.3 320 CGC-T1212- OU08B

A 34 PE Insulation Multipairs, Layers, Overall Screen of Plain or Tinned Copper Wire Braid Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size pairs No.x dia. Res. At thickness thickness diameter weight 20oC mm2 No. No. x mm Ohm /Km mm mm mm Kg/km - 2 7 x 0.43 18.4 0.6 1.0 10.8 135 CGC-T1202-OU12B 4 7 x 0.43 18.4 0.6 1.0 11.6 160 CGC-T1204-OU12B

1.0 6 7 x 0.43 18.4 0.6 1.2 12.8 255 CGC-T1206-OU12B 8 7 x 0.43 18.4 0.6 1.2 15.4 280 CGC-T1208-OU12B 10 7 x 0.43 18.4 0.6 1.3 17.2 345 CGC-T1210-OU12B 12 7 x 0.43 18.4 0.6 1.3 17.8 400 CGC-T1212-OU12B 2 7 x 0.49 14.2 0.6 1.0 11.4 165 CGC-T1202-OU12B 4 7 x 0.49 14.2 0.6 1.2 13.5 195 CGC-T1204-OU12B 6 7 x 0.49 14.2 0.6 1.3 14.7 260 CGC-T1206-OU12B 1.3 8 7 x 0.49 14.2 0.6 1.3 16.6 340 CGC-T1208-OU12B 10 7 x 0.49 14.2 0.6 1.3 18.1 410 CGC-T1210- OU12B 12 7 x 0.49 14.2 0.6 1.3 20.2 480 CGC-T1212-OU12B 2 7 x 0.53 12.6 0.6 1.2 12.9 195 CGC-T1202- OU12B 4 7 x 0.53 12.6 0.6 1.2 14.1 230 CGC-T1204-OU12B 6 7 x 0.53 12.6 0.6 1.3 17.8 390 CGC-T1206-OU12B 1.5 8 7 x 0.53 12.6 0.6 1.3 18.6 405 CGC-T1208-OU12B 10 7 x 0.53 12.6 0.6 1.3 20.6 490 CGC-T1210-OU12B 12 7 x 0.53 12.6 0.6 1.3 21.3 564 CGC-T1212-OU12B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

A 35 B. Fire Resistant & Fire Alarm Cables B. Fire Resistant & Fire Alarm Cables

Fire Resistant Cables, Multicores, Layers, Collective Screen, Stranded Conductor ...…………...…………. 2 Fire Resistant Cables, Multipairs, Layers, Collective Screen, Stranded Conductor ...…………...………….. 3 Fire Resistant Cables, Multipairs, Layers, Individual and Collective Screen, Stranded Conductor ...…….. 5 Fire Alarm Cables, Multicores, Unscreened, Stranded Conductor ...... 7 Fire Alarm Cables, Multipairs, Layers, Collective Screen, Stranded Conductor ...... 8 Fire Alarm Cables, Multicores, Unscreened, Solid Conductor ...... 9 Fire Alarm Cables, Multipairs, Layers, Collective Screen, Solid Conductor...... 10 Fire Alarm Cables, Multicores, Unscreened, Flexible Conductor ...... 11 Fire Alarm Cables, Multipairs, Layers, Collective Screen, Flexible Conductor ...... 12

B 1 Fire Resistant Cables Multicores, Layers, Collective Screen, Stranded Conductor Application: These cables are used in fire fighting alarm systems in hazardous area where the safety is highly required during fire condition.

Engineering Specification:

Standard: Colour code: IEC 60502 Black continuously numbered

Rated Voltage: Screen: 600 / 1000 V Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester Conductor: tapes Stranded plain / tinned annealed copper Sheath: Halogen free, low smoke thermoplastic material, Insulation: red colour Flame barrier mica tape, cross-linked polyethylene Minimum bending radius: 7.5 x d (d= overall diameter) Assembly:

Cores twisted together in concentric Fire resistant property: UIC Elsewedy Fire Resistant Cables layers and wrapped by polyester tapes 750oC according to IEC 331

Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. Cores 20oC thickness thickness diameter weight

mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -

2 7 x 0.52 12.1 0.7 1.8 10.5 115 CBA-TL102-JU15B

5 7 x 0.52 12.1 0.7 1.8 12.8 204 CBA-TL105-JU15B

7 7 x 0.52 12.1 0.7 1.8 13.8 212 CBA-TL107-JU15B

10 7 x 0.52 12.1 0.7 1.8 17.2 352 CBA-TL110-JU15B 1.5 12 7 x 0.52 12.1 0.7 1.8 17.8 402 CBA-TL112-JU15B

19 7 x 0.52 12.1 0.7 1.8 20.6 582 CBA-TL119-JU15B

24 7 x 0.52 12.1 0.7 1.8 23.9 720 CBA-TL124-JU15B

30 7 x 0.52 12.1 0.7 1.8 25.3 870 CBA-TL130-JU15B

37 7 x 0.52 12.1 0.7 1.8 27.3 1040 CBA-TL137-JU15B

2 7 x 0.67 7.41 0.7 1.8 11.4 146 CBA-TL102-JU18B

5 7 x 0.67 7.41 0.7 1.8 14.1 260 CBA-TL105-JU18B

7 7 x 0.67 7.41 0.7 1.8 15.2 325 CBA-TL107-JU18B

10 7 x 0.67 7.41 0.7 1.8 19.0 435 CBA-TL110-JU18B

2.5 12 7 x 0.67 7.41 0.7 1.8 19.6 500 CBA-TL112-JU18B

19 7 x 0.67 7.41 0.7 1.8 22.8 700 CBA-TL119-JU18B

24 7 x 0.67 7.41 0.7 1.8 26.6 860 CBA-TL124-JU18B

30 7 x 0.67 7.41 0.7 1.9 28.4 1040 CBA-TL130-JU18B

37 7 x 0.37 7.41 0.7 1.9 30.1 1250 CBA-TL137-JU18B

The above data are approximate and subject to normal manufacturing tolerance. Other types can be provided on specific request. We can meet all other standard as BS 5308 and IEC 502.

B 2 Fire Resistant Cables Multipairs, Layers, Collective Screen, Stranded Conductor Application: These cables are used in fire fighting alarm systems in hazardous area where the safety is highly required during fire condition.

Engineering Specification:

Standard: Screen: BS-5308 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes. Rated Voltage: 300 / 500 V Sheath: Halogen free, low smoke thermoplastic Conductor: material, red colour Stranded plain / tinned annealed copper Minimum bending radius: Insulation: 6 x d (d= overall diameter) Flame barrier mica tape, cross-linked polyethylene Fire resistant property: o 750 C according to IEC 331 UIC Elsewedy Fire Resistant Cables Assembly: Cores twisted to form pairs, pairs twisted in Packing: concentric layers and wrapped by polyester On non-returnable wooden drums tapes

Colour code: Black / White continuously numbered, or identification tapes numbered Technical Information

Conductor Number Nominal Nominal Approximate Approximate Conductor of insulation sheath overall net UIC – code size Max. DC Res. At pairs No.x dia. thickness thickness diameter weight 20oC

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.2 11.1 98 CBC-TL202-JU05R 4 7 x 0.3 39.2 0.6 1.2 12.8 145 CBC-TL204-JU05R 6 7 x 0.3 39.2 0.6 1.2 15.3 200 CBC-TL206-JU05R 8 7 x 0.3 39.2 0.6 1.3 17.0 270 CBC-TL208-JU05R

0.5 10 7 x 0.3 39.2 0.6 1.3 18.8 310 CBC-TL210-JU05R 12 7 x 0.3 39.2 0.6 1.4 19.9 355 CBC-TL212-JU05R 16 7 x 0.3 39.2 0.6 1.4 22.5 454 CBC-TL216-JU05R 20 7 x 0.3 39.2 0.6 1.5 25.0 560 CBC-TL220-JU05R 24 7 x 0.3 39.2 0.6 1.5 27.1 650 CBC-TL224-JU05R 30 7 x 0.3 39.2 0.6 1.6 30.1 800 CBC-TL230-JU05R 2 7 x 0.37 24.6 0.6 1.2 11.8 110 CBC-TL202-JU08R 4 7 x 0.37 24.6 0.6 1.2 13.7 175 CBC-TL204-JU08R 6 7 x 0.37 24.6 0.6 1.3 16.6 245 CBC-TL206-JU08R 8 7 x 0.37 24.6 0.6 1.3 17.7 305 CBC-TL208-JU08R 10 7 x 0.37 24.6 0.6 1.3 20.1 370 CBC-TL210-JU08R 0.75 12 7 x 0.37 24.6 0.6 1.4 21.3 435 CBC-TL212-JU08R 16 7 x 0.37 24.6 0.6 1.4 24.1 555 CBC-TL216-JU08R 20 7 x 0.37 24.6 0.6 1.5 26.8 685 CBC-TL220-JU08R 24 7 x 0.37 24.6 0.6 1.5 29.1 800 CBC-TL224-JU08R 30 7 x 0.37 24.6 0.6 1.6 32.3 990 CBC-TL230-JU08R

B 3 Fire Resistant Cables Multipairs, Layers, Collective Screen, Stranded Conductor Technical Information Conductor Number Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. pairs 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.2 12.4 127 CBC-TL202-JU12R 4 7 x 0.43 18.4 0.6 1.3 14.6 205 CBC-TL204-JU12R 6 7 x 0.43 18.4 0.6 1.3 17.5 285 CBC-TL206-JU12R 8 7 x 0.43 18.4 0.6 1.3 18.7 355 CBC-TL208-JU12R 10 7 x 0.43 18.4 0.6 1.3 21.3 435 CBC-TL210-JU12R 1 12 7 x 0.43 18.4 0.6 1.4 22.5 510 CBC-TL212-JU12R 16 7 x 0.43 18.4 0.6 1.5 25.7 685 CBC-TL216-JU12R 20 7 x 0.43 18.4 0.6 1.6 28.6 820 CBC-TL220-JU12R 24 7 x 0.43 18.4 0.6 1.6 31.0 962 CBC-TL224-JU12R 30 7 x 0.43 18.4 0.6 1.7 34.5 1185 CBC-TL230-JU12R 2 7 x 0.53 12.6 0.6 1.2 13.3 155 CBC-TL202-JU15R 4 7 x 0.53 12.6 0.6 1.3 15.8 258 CBC-TL204-JU15R 6 7 x 0.53 12.6 0.6 1.3 19.0 360 CBC-TL206-JU15R 8 7 x 0.53 12.6 0.6 1.3 20.3 455 CBC-TL208-JU15R 10 7 x 0.53 12.6 0.6 1.3 23.2 555 CBC-TL210-JU15R 1.5 12 7 x 0.53 12.6 0.6 1.4 24.5 660 CBC-TL212-JU15R 16 7 x 0.53 12.6 0.6 1.5 28.1 860 CBC-TL216-JU15R 20 7 x 0.53 12.6 0.6 1.6 31.2 1060 CBC-TL220-JU15R 24 7 x 0.53 12.6 0.6 1.7 34.2 1290 CBC-TL224-JU15R 30 7 x 0.53 12.6 0.6 1.7 37.7 1550 CBC-TL230-JU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request. • We can meet all other standard as BS 5308 and IEC 502.

B 4 Fire Resistant Cables Multipairs, Layers, Individual and Collective Screen, Stranded Conductor Application: These cables are used in fire fighting alarm systems in hazardous area where the safety is highly required during fire condition.

Engineering Specification:

Standard: Screen: BS-5308 Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester Rated Voltage: tapes 300 / 500 V

Conductor: Sheath: Stranded plain / tinned annealed Halogen free, low smoke thermoplastic material, copper red colour

Insulation: Minimum bending radius: Flame barrier mica tape, cross-linked 6 x d (d= overall diameter) polyethylene Fire resistant property: Assembly: 750oC according to IEC 331

Cores twisted to form pairs, pairs screened UIC Elsewedy Fire Resistant Cables by aluminium polyester tapes, screened Packing: pairs twisted in concentric layers and On non-returnable wooden drums wrapped by polyester tapes

Colour code: Black / White continuously numbered, or Identification tapes numbered Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. pairs 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.3 39.2 0.6 1.2 11.8 110 CBC-TL202-SU05R 4 7 x 0.3 39.2 0.6 1.2 13.7 170 CBC-TL204-SU05R 6 7 x 0.3 39.2 0.6 1.2 16.4 234 CBC-TL206-SU05R 8 7 x 0.3 39.2 0.6 1.3 17.7 296 CBC-TL208-SU05R 0.5 10 7 x 0.3 39.2 0.6 1.3 20.1 360 CBC-TL210-SU05R 12 7 x 0.3 39.2 0.6 1.4 21.3 425 CBC-TL212-SU05R 16 7 x 0.3 39.2 0.6 1.4 24.1 540 CBC-TL216-SU05R 20 7 x 0.3 39.2 0.6 1.5 26.8 670 CBC-TL220-SU05R 24 7 x 0.3 39.2 0.6 1.5 29.1 780 CBC-TL224-SU05R 30 7 x 0.3 39.2 0.6 1.6 32.3 960 CBC-TL230-SU05R 2 7 x 0.37 24.6 0.6 1.2 12.5 126 CBC-TL202-SU08R 4 7 x 0.37 24.6 0.6 1.2 14.5 200 CBC-TL204-SU08R 6 7 x 0.37 24.6 0.6 1.3 17.7 285 CBC-TL206-SU08R 8 7 x 0.37 24.6 0.6 1.3 18.8 350 CBC-TL208-SU08R 10 7 x 0.37 24.6 0.6 1.3 21.5 430 CBC-TL210-SU08R 0.75 12 7 x 0.37 24.6 0.6 1.4 22.7 505 CBC-TL212-SU08R 16 7 x 0.37 24.6 0.6 1.4 25.8 650 CBC-TL216-SU08R 20 7 x 0.37 24.6 0.6 1.5 28.7 800 CBC-TL220-SU08R 24 7 x 0.37 24.6 0.6 1.5 31.1 935 CBC-TL224-SU08R 30 7 x 0.37 24.6 0.6 1.6 34.6 1155 CBC-TL230-SU08R B 5 Fire Resistant Cables Multipairs, Layers, Individual and Collective Screen, Stranded Conductor Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. insulation sheath overall net UIC – code size No.x dia. pairs At 20oC thickness thickness diameter weight mm2 No. x No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.4 0.6 1.2 13.1 142 CBC-TL202-SU12R 4 7 x 0.43 18.4 0.6 1.3 15.5 230 CBC-TL204-SU12R 6 7 x 0.43 18.4 0.6 1.3 18.6 325 CBC-TL206-SU12R 8 7 x 0.43 18.4 0.6 1.3 19.8 405 CBC-TL208-SU12R

1 10 7 x 0.43 18.4 0.6 1.3 22.6 490 CBC-TL210-SU12R 12 7 x 0.43 18.4 0.6 1.4 23.9 585 CBC-TL212-SU12R 16 7 x 0.43 18.4 0.6 1.5 27.4 760 CBC-TL216-SU12R 20 7 x 0.43 18.4 0.6 1.6 30.4 940 CBC-TL220-SU12R 24 7 x 0.43 18.4 0.6 1.6 33.0 1100 CBC-TL224-SU12R 30 7 x 0.43 18.4 0.6 1.7 36.7 1360 CBC-TL230-SU12R 2 7 x 0.53 12.6 0.6 1.2 14.0 166 CBC-TL202-SU15R 4 7 x 0.53 12.6 0.6 1.3 16.7 286 CBC-TL204-SU15R 6 7 x 0.53 12.6 0.6 1.3 20.1 400 CBC-TL206-SU15R 8 7 x 0.53 12.6 0.6 1.3 21.5 505 CBC-TL208-SU15R 10 7 x 0.53 12.6 0.6 1.3 24.5 620 CBC-TL210-SU15R 1.5 12 7 x 0.53 12.6 0.6 1.4 26.0 735 CBC-TL212-SU15R 16 7 x 0.53 12.6 0.6 1.5 29.7 960 CBC-TL216-SU15R 20 7 x 0.53 12.6 0.6 1.6 33.0 1185 CBC-TL220-SU15R 24 7 x 0.53 12.6 0.6 1.7 36.1 1410 CBC-TL224-SU15R 30 7 x 0.53 12.6 0.6 1.7 40.0 1725 CBC-TL230-SU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request. • We can meet all other standard as BS 5308 and IEC 502.

B 6 Fire Alarm Cables Multicores, Unscreened, Stranded Conductor Application: These cables are used for communication and signaling in fire alarm systems.

Engineering Specification:

Standard: Colour code: BS-5308 Two Core: red, black Three Core: red, black, blue Rated Voltage: Four Core: red, yellow, blue, black 300 / 500 V Sheath: Conductor: Flame retardant polyvinylchloride, red coloured Stranded annealed plain copper Minimum bending radius: Insulation: 7.5 x d (d= overall diameter) polyvinylchloride rated for 105oC

Assembly: Packing: Cores twisted together in concentric layers On non-returnable wooden drums UIC Elsewedy Fire Alarm Cables UIC Elsewedy Fire

Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of insulation sheath overall net UIC – code size Cores Max. DC Res. thickness thickness diameter weight No.x dia. At 20oC

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 2 7 x 0.43 18.1 0.6 0.8 6.6 65 CSC-TA202-AU12R

1 3 7 x 0.43 18.1 0.6 0.8 7.0 79 CSC-TA203-AU12R

4 7 x 0.43 18.1 0.6 0.8 7.6 98 CSC-TA204-AU12R

2 7 x 0.52 12.1 0.6 0.8 7.1 81 CSC-TA202-AU15R

1.5 3 7 x 0.52 12.1 0.6 0.9 7.8 103 CSC-TA203-AU15R

4 7 x 0.52 12.1 0.6 0.9 8.5 128 CSC-TA204-AU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

B 7 Fire Alarm Cables Multipairs, Layers, Collective Screen, Stranded Conductor Application: These cables are used for communication and signaling in fire alarm systems.

Engineering Specification:

Standard: Screen: BS-5308 Collective screen of aluminium polyester tap with Rated Voltage: tinned drainwire and wrapped by polyester tapes 300 / 500 V Sheath: Conductor: Flame retardant polyvinylchloride, red coloured Stranded annealed plain copper Minimum bending radius: Insulation: 7.5 x d (d= overall diameter) Polyvinylchloride rated for 105oC

Assembly: Packing: Cores twisted to form pairs, pairs twisted in On non-returnable wooden drums concentric layers and wrapped by polyester tapes.

Colour code: Red / Black continuously numbered, or Alarm Cables UIC Elsewedy Fire identification tapes numbered Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. pairs 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 2 7 x 0.53 12.6 0.6 1.2 12.0 155 CSC-TA202-JU12R

4 7 x 0.53 12.6 0.6 1.2 14.0 253 CSC-TA203-JU12R

8 7 x 0.53 12.6 0.6 1.3 18.1 457 CSC-TA208-JU12R

12 7 x 0.53 12.6 0.6 1.3 21.6 652 CSC-TA212-JU15R 1.5 16 7 x 0.53 12.6 0.6 1.5 24.7 860 CSC-TA216-JU15R

20 7 x 0.53 12.6 0.6 1.5 27.5 1058 CSC-TA220-JU15R

24 7 x 0.53 12.6 0.6 1.7 30.2 1270 CSC-TA224-JU15R

30 7 x 0.53 12.6 0.6 2.0 33.9 1600 CSC-TA230-JU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

B 8 Fire Alarm Cables Multicores, Unscreened, Solid Conductor Application: These cables are used for communication and signaling in fire alarm systems.

Engineering Specification:

Standard: Sheath: BS-5308 Flame retardant polyvinylchloride, red coloured Rated Voltage: 300 / 500 V Minimum bending radius: 7.5 x d (d= overall diameter) Conductor: Solid annealed plain copper Packing: On non-returnable wooden drums Insulation: polyvinylchloride rated for 105oC UIC Elsewedy Fire Alarm Cables UIC Elsewedy Fire Assembly: Cores twisted together in concentric layers

Colour code: Two Core: red, black Three Core: red, black, blue Four Core: red, yellow, blue, black Technical Information

Conductor Nominal Nominal Approximate Conductor Number Approximate Insulation Theath overall Size of Cores Max.dc net Weight No.x Dia Resis. At thickness Thickness Diameter UIC-Code 20C Ohm/ mm2 No. No.x mm mm mm mm kg/km Km 2 1x1.13 18.1 0.6 0.8 6.3 49 CSC-SA102-AU12R

1 3 1x1.13 18.1 0.6 0.8 6.6 65 CSC-SA103-AU12R

4 1x1.13 18.1 0.6 0.8 7.2 81 CSC-SA104-AU12R

2 1x1.35 12.1 0.6 0.8 6.7 60 CSC-SA102-AU15R

1.5 3 1x1.35 12.1 0.6 0.9 7.3 84 CSC-SA103-AU15R

4 1x1.35 12.1 0.6 0.9 8 105 CSC-SA104-AU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

B 9 Fire Alarm Cables Multipairs, Layers, Collective Screen, Solid Conductor Application: These cables are used for communication and signaling in fire alarm systems.

Engineering Specification: Standard: Screen: BS-5308 Collective screen of aluminium polyester tap with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300 / 500 V Sheath: Flame retardant polyvinylchloride, red coloured Conductor: Solid annealed plain copper Minimum bending radius: 7.5 x d (d= overall diameter) Insulation: Polyvinylchloride rated for 105oC Packing: On non-returnable wooden drums Assembly:

Cores twisted to form pairs, pairs twisted in Alarm Cables UIC Elsewedy Fire concentric layers and wrapped by polyester tapes

Colour code: Red / Black continuously numbered, or identification tapes numbered Technical Information

Conductor Nominal Nominal Approximate Conductor Number Approximate Max.dc Insulation Theath overall Size of Pairs No. x Dia Resis. At net Weight thickness Thickness Diameter UIC-Code 20C No. x mm2 No. Ohm/Km mm mm mm kg/km mm 2 1x1.35 12.1 0.6 1.2 11.3 142 CSC-SA202-JU15R

4 1x1.35 12.1 0.6 1.2 13.1 232 CSC-SA204-JU15R

8 1x1.35 12.1 0.6 1.3 16.9 418 CSC-SA208-JU15R

12 1x1.35 12.1 0.6 1.3 20.1 596 CSC-SA212-JU15R 1.5 16 1x1.35 12.1 0.6 1.5 23.3 293 CSC-SA216-JU15R

20 1x1.35 12.1 0.6 1.5 25.6 967 CSC-SA220-JU15R

24 1x1.35 12.1 0.6 1.5 27.8 1139 CSC-SA224-JU15R

30 1x1.35 12.1 0.6 1.7 31.1 1426 CSC-SA230-JU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

B 10 Fire Alarm Cables Multicores, Unscreened, Flexible Conductor Application: These cables are used for communication and signaling in fire alarm systems.

Engineering Specification:

Standard: Sheath: BS-5308 Flame retardant polyvinylchloride, red coloured

Rated Voltage: Minimum bending radius: 300 / 500 V 7.5 x d (d= overall diameter) Conductor: Flexible annealed plain copper Packing: On non-returnable wooden drums Insulation: Polyvinylchloride rated for 105oC

Assembly: Cores twisted together in concentric layers Alarm Cables UIC Elsewedy Fire

Colour code: Two Core: red, black Three Core: red, black, blue Four Core: red, yellow, blue, black Technical Information Conductor Nominal Nominal Approximate Conductor Number Approximate Max.dc Insulation Theath overall Size of Cores No.x Dia Resis. At net Weight UIC-Code thickness Thickness Diameter 20C mm2 No. No.x mm Ohm/Km mm mm mm kg/km 2 32x0.19 19.5 0.6 0.8 6.5 49 CSC-FA102-AU12R

1 3 32x0.19 19.5 0.6 0.8 6.9 75 CSC-FA103-AU12R

4 32x0.19 19.5 0.6 0.8 7.5 92 CSC-FA104-AU12R

2 36x0.22 13.3 0.6 0.8 7.1 78 CSC-FA102-AU15R

1.5 3 36x0.22 13.3 0.6 0.9 7.7 99 CSC-FA103-AU15R

4 36x0.22 13.3 0.6 0.9 8.4 122 CSC-FA104-AU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

B 11 Fire Alarm Cables Multipairs, Layers, Collective Screen, Flexible Conductor Application: These cables are used for communication and signaling in fire alarm systems.

Engineering Specification:

Standard: Screen: BS-5308 Collective screen of aluminium polyester tap with tinned drain wire and wrapped by polyester tapes Rated Voltage: 300 / 500 V Sheath: Flame retardant polyvinylchloride, red coloured Conductor: Flexible annealed plain copper Minimum bending radius: 7.5 x d (d= overall diameter) Insulation: Polyvinylchloride rated for 105oC Packing: On non-returnable wooden drums Assembly:

Cores twisted to form pairs, pairs twisted in Alarm Cables UIC Elsewedy Fire concentric layers and wrapped by polyester tapes

Colour code: Red/Black continuously numbered, or identification tapes numbered

Technical Information Conductor Nominal Nominal Approximate Conductor Number of Approximate Max.dc Insulation Theath overall Size Pairs No.x Dia net Weight Resis. At 20C thickness Thickness Diameter UIC-Code No.x mm2 No. Ohm/Km mm mm mm kg/km mm 2 36x0.22 13.3 0.6 1.2 11.8 143 CSC-FA202-JU15R

4 36x0.22 13.3 0.6 1.2 13.7 229 CSC-FA204-JU15R

8 36x0.22 13.3 0.6 1.3 17.8 412 CSC-FA208-JU15R

12 36x0.22 13.3 0.6 1.5 21.6 585 CSC-FA212-JU15R 1.5 16 36x0.22 13.3 0.6 1.5 24.4 777 CSC-FA216-JU15R

20 36x0.22 13.3 0.6 1.5 26.9 947 CSC-FA220-JU15R

24 36x0.22 13.3 0.6 1.7 29.6 1143 CSC-FA224-JU15R

30 36x0.22 13.3 0.6 1.7 32.7 1395 CSC-FA230-JU15R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

B 12 B 13 C.C 14 Control Cables C. Control Cables

Solid Copper Conductors, PVC Insulation, PVC Sheathed ……………………………………………….… 2 Stranded Copper Conductors, PVC Insulation, PVC Sheathed ………………………………....………. 4 Stranded Copper Conductors, PVC Insulation, Copper Tape Screened, PVC Sheathed ...... ………. 6 Stranded Copper Conductors, PVC Insulation, Steel Tape Armoured, PVC Sheathed ....….…………. 8 Stranded Copper Conductors, PVC Insulation, Steel Wire Armoured, PVC Sheathed ..…………….… 10 Solid Copper Conductors PVC Insulation, PVC Sheathed Application: For outdoor and indoor installations in damp and wet locations, connecting signaling and control units in industry, in railways, in traffic signals, in thermopower and hydropower stations. They are laid in air, in ducts, in trenches, in steel support brackets or direct in ground, when well protected.

Engineering Specification:

Standard: Colour code: IEC – 60502 Black cores with white numbers and one green yellow core Rated Voltage: 300 / 500 V Sheath: Flame retardant polyvinylchloride, black or grey Conductor: colour Soft annealed solid copper wire as per class 1 of IEC 228 Minimum bending radius: 15 x d (d= overall diameter) Insulation: Polyvinylchloride rated 70oC or 85oC Temperature rating: +5oC up to + 50oC during operation Assembly: Cores twisted together to form a round Packing: assembly cable with fillers whenever On non-returnable wooden drums necessary

Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. cores 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 5 1x1.38 12.1 0.8 1.8 11.8 200 CPA-SA105-UU15B

7 1x1.38 12.1 0.8 1.8 12.7 250 CPA-SA107-UU15B

10 1x1.38 12.1 0.8 1.8 15.7 340 CPA-SA110-UU15B

12 1x1.38 12.1 0.8 1.8 16.2 385 CPA-SA112-UU15B

14 1x1.38 12.1 0.8 1.8 17.0 435 CPA-SA114-UU15B 1.5 16 1x1.38 12.1 0.8 1.8 17.8 490 CPA-SA116-UU15B

19 1x1.38 12.1 0.8 1.8 18.7 560 CPA-SA119-UU15B

24 1x1.38 12.1 0.8 1.8 21.7 700 CPA-SA124-UU15B

30 1x1.38 12.1 0.8 1.8 23.8 850 CPA-SA130-UU15B

37 1x1.38 12.1 0.8 1.8 24.7 1000 CPA-SA137-UU15B

44 1x1.38 12.1 0.8 1.8 28.4 1200 CPA-SA144-UU15B

C 2 Solid Copper Conductors PVC Insulation, PVC Sheathed Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC – code size No.x dia. Cores 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 5 1x1.78 7.41 0.8 1.8 12.9 260 CPA-SA105-UU18B 7 1x1.78 7.41 0.8 1.8 13.8 330 CPA-SA107-UU18B 10 1x1.78 7.41 0.8 1.8 17.2 450 CPA-SA110-UU18B 12 1x1.78 7.41 0.8 1.8 17.7 540 CPA-SA112-UU18B 14 1x1.78 7.41 0.8 1.8 18.6 600 CPA-SA114-UU18B 2.5 16 1x1.78 7.41 0.8 1.8 19.6 670 CPA-SA116-UU18B 19 1x1.78 7.41 0.8 1.8 20.6 780 CPA-SA119-UU18B 24 1x1.78 7.41 0.8 1.8 24.0 1030 CPA-SA124-UU18B 30 1x1.78 7.41 0.8 1.8 25.4 1160 CPA-SA130-UU18B 37 1x1.78 7.41 0.8 1.9 27.4 1410 CPA-SA137-UU18B 44 1x1.78 7.41 0.8 2.0 31.2 1670 CPA-SA144-UU18B 5 1x2.26 4.61 1.0 1.8 15.3 430 CPA-SA105-UU21B 7 1x2.26 4.61 1.0 1.8 16.5 480 CPA-SA107-UU21B 10 1x2.26 4.61 1.0 1.8 20.8 670 CPA-SA110-UU21B 12 1x2.26 4.61 1.0 1.8 21.5 780 CPA-SA112-UU21B

4.0 14 1x2.26 4.61 1.0 1.8 22.6 890 CPA-SA114-UU21B 16 1x2.26 4.61 1.0 1.8 23.8 1000 CPA-SA116-UU21B 19 1x2.26 4.61 1.0 1.9 25.1 1170 CPA-SA119-UU21B 24 1x2.26 4.61 1.0 2.0 29.6 1460 CPA-SA124-UU21B 30 1x2.26 4.61 1.0 2.1 31.6 1830 CPA-SA130-UU21B 37 1x2.26 4.61 1.0 2.2 34.1 2320 CPA-SA137-UU21B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 3 Stranded Copper Conductors PVC Insulation, PVC Sheathed Application: For outdoor and indoor installations in damp and wet locations, connecting signaling and control units in industry, in railways, in traffic signals, in thermopower and hydropower stations. They are laid in air, in ducts, in trenches, in steel support brackets or direct in ground, when well protected.

Engineering Specification:

Standard: Colour code: IEC – 60502 Black cores with white numbers and one green yellow core Rated Voltage: 600 / 1000 V Sheath: Flame retardant polyvinylchloride, black or grey Conductor: colour Soft annealed solid copper wire as per class 1 of IEC 228 Minimum bending radius: 15 x d (d= overall diameter) Insulation: Polyvinylchloride rated 70oC or 85oC Temperature rating: +5oC up to + 50oC during operation Assembly: Cores twisted together to form a round Packing: assembly cable with fillers whenever On non-returnable wooden drums necessary

Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. insulation sheath overall net UIC – code size No.x dia. Cores At 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 5 7x 0.52 12.1 0.8 1.8 12.3 215 CPA-SA105-LU15B

7 7x 0.52 12.1 0.8 1.8 13.3 265 CPA-SA107-LU15B

10 7x 0.52 12.1 0.8 1.8 16.5 360 CPA-SA110-LU15B

12 7x 0.52 12.1 0.8 1.8 17.0 410 CPA-SA112-LU15B

14 7x 0.52 12.1 0.8 1.8 17.8 465 CPA-SA114-LU15B 1.5 16 7x 0.52 12.1 0.8 1.8 18.7 530 CPA-SA116-LU15B

19 7x 0.52 12.1 0.8 1.8 19.7 600 CPA-SA119-LU15B

24 7x 0.52 12.1 0.8 1.8 22.9 740 CPA-SA124-LU15B

30 7x 0.52 12.1 0.8 1.8 24.2 890 CPA-SA130-LU15B

37 7x 0.52 12.1 0.8 1.8 26.1 1070 CPA-SA137-LU15B

44 7x 0.52 12.1 0.8 1.8 30.2 1295 CPA-SA144-LU15B

C 4 Stranded Copper Conductors PVC Insulation, PVC Sheathed Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. insulation sheath overall net UIC – code size No.x dia. Cores At 20oC thickness thickness diameter weight No. x mm2 No. Ohm /Km mm mm mm Kg/Km - mm 5 7x0.67 7.41 0.8 1.8 13.4 275 CPA-SA105-UU18B 7 7x0.67 7.41 0.8 1.8 14.5 350 CPA-SA107-LU18B 10 7x0.67 7.41 0.8 1.8 18.1 480 CPA-SA110-LU18B 12 7x0.67 7.41 0.8 1.8 18.7 555 CPA-SA112-LU18B 14 7x0.67 7.41 0.8 1.8 19.6 630 CPA-SA114-LU18B 2.5 16 7x0.67 7.41 0.8 1.8 20.6 710 CPA-SA116-UU18B 19 7x0.67 7.41 0.8 1.8 21.7 820 CPA-SA119-LU18B 24 7x0.67 7.41 0.8 1.8 25.3 1020 CPA-SA124-LU18B 30 7x0.67 7.41 0.8 1.8 26.8 1235 CPA-SA130-LU18B 37 7x0.67 7.41 0.8 1.9 28.9 1495 CPA-SA137-LU18B 44 7x0.67 7.41 0.8 2.0 33.5 1800 CPA-SA144-LU18B 5 7x0.85 4.61 1.0 1.8 16.1 440 CPA-SA105-UU21B 7 7x0.85 4.61 1.0 1.8 17.4 520 CPA-SA107-LU21B 10 7x0.85 4.61 1.0 1.8 22.0 720 CPA-SA110-LU21B 12 7x0.85 4.61 1.0 1.8 22.7 840 CPA-SA112-LU21B

4.0 14 7x0.85 4.61 1.0 1.8 23.9 950 CPA-SA114-LU21B 16 7x0.85 4.61 1.0 1.8 25.2 1070 CPA-SA116-UU21B 19 7x0.85 4.61 1.0 1.9 26.6 1260 CPA-SA119-LU21B 24 7x0.85 4.61 1.0 2.0 31.4 1580 CPA-SA124-LU21B 30 7x0.85 4.61 1.0 2.1 33.5 1965 CPA-SA130-LU21B 37 7x0.85 4.61 1.0 2.2 36.2 2510 CPA-SA137-LU21B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 5 Stranded Copper Conductors PVC Insulation, Copper Tape Screened, PVC Sheathed

Application: For outdoor installations in damp and wet locations, connecting signaling and control units in industry in railways, in traffic signals, in thermopower and hydropower stations. Where electrical interference could alter signal transmission, They are laid in air, in ducts, in trenches, in steel support brackets or direct in ground, when well protected.

Engineering Specification:

Standard: Bedding: IEC – 60502 Polyvinylchoride rated 70oC

Rated Voltage: Screen : 600 / 1000 V Copper tape helically applied over the bedding

Conductor: Sheath: Soft annealed stranded copper wire as per Flame retardant polyvinylchloride, black or grey class 2 of IEC 228 colour

Insulation: Minimum bending radius: Polyvinylchloride rated 70oC or 85oC 15 x d (d= overall diameter)

Assembly: Temperature rating: Cores twisted together to form a round +5oC up to + 50oC during operation assembly cable with fillers whenever necessary Packing: On non-returnable wooden drum Colour code: Black cores with white numbers and one green yellow core Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. insulation sheath overall net UIC – code size No.x dia. cores At 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 5 7x 0.52 12.1 0.8 1.8 15.3 340 CPA-TA105-NU15B

7 7x 0.52 12.1 0.8 1.8 15.7 370 CPA-TA107-NU15B

10 7x 0.52 12.1 0.8 1.8 18.9 495 CPA-TA110-NU15B

12 7x 0.52 12.1 0.8 1.8 19.4 550 CPA-TA112-NU15B

14 7x 0.52 12.1 0.8 1.8 20.2 610 CPA-TA114-NU15B 1.5 16 7x 0.52 12.1 0.8 1.8 21.1 670 CPA-TA116-NU15B

19 7x 0.52 12.1 0.8 1.8 22.1 760 CPA-TA119-NU15B

24 7x 0.52 12.1 0.8 1.8 25.3 930 CPA-TA124-NU15B

30 7x 0.52 12.1 0.8 1.8 27.5 1115 CPA-TA130-NU15B

37 7x 0.52 12.1 0.8 1.9 28.5 1290 CPA-TA137-NU15B

44 7x 0.52 12.1 0.8 2.0 31.0 1500 CPA-TA144-NU15B

C 6 Stranded Copper Conductors PVC Insulation, Copper Tape Screened, PVC Sheathed Technical Information Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC insulation sheath overall net UIC – code size No.x dia. Cores Res. At 20oC thickness thickness diameter weight

2 No. x mm No. mm Ohm /Km mm mm mm Kg/Km - 5 7x0.67 7.41 0.8 1.8 15.8 390 CPA-TA105-NU18B 7 7x0.67 7.41 0.8 1.8 16.9 470 CPA-TA107-NU18B 10 7x0.67 7.41 0.8 1.8 20.5 630 CPA-TA110-NU18B 12 7x0.67 7.41 0.8 1.8 21.1 710 CPA-TA112-NU18B 14 7x0.67 7.41 0.8 1.8 22.0 800 CPA-TA114-NU18B 2.5 16 7x0.67 7.41 0.8 1.8 23.0 875 CPA-TA116-NU18B 19 7x0.67 7.41 0.8 1.8 24.1 1000 CPA-TA119-NU18B 24 7x0.67 7.41 0.8 1.8 27.7 1225 CPA-TA124-NU18B 30 7x0.67 7.41 0.8 1.9 29.8 1470 CPA-TA130-NU18B 37 7x0.67 7.41 0.8 2.0 31.5 1750 CPA-TA137-NU18B 44 7x0.67 7.41 0.8 2.1 35.7 2140 CPA-TA144-NU18B 5 7x0.85 4.61 1.0 1.8 18.5 540 CPA-TA105-NU21B 7 7x0.85 4.61 1.0 1.8 19.5 670 CPA-TA107-NU21B 10 7x0.85 4.61 1.0 1.8 24.4 850 CPA-TA110-NU21B 12 7x0.85 4.61 1.0 1.8 25.2 980 CPA-TA112-NU21B 4.0 14 7x0.85 4.61 1.0 1.8 26.3 1160 CPA-TA114-NU21B 16 7x0.85 4.61 1.0 1.9 27.6 1310 CPA-TA116-NU21B 19 7x0.85 4.61 1.0 2.0 29.0 1520 CPA-TA119-NU21B 24 7x0.85 4.61 1.0 2.1 33.8 1900 CPA-TA124-NU21B 30 7x0.85 4.61 1.0 2.3 35.9 2350 CPA-TA130-NU21B 37 7x0.85 4.61 1.0 2.4 38.8 2970 CPA-TA137-NU21B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 7 Stranded Copper Conductors PVC Insulation, Steel Tape Armoured, PVC Sheathed Application: For outdoor and indoor installations in damp and wet locations, Laid Direct in the ground, where mechanical damages are expected to occur. They are normally used in connecting signaling and control units in industry, in railways, in traffic signals, in thermopower and hydropower stations. Engineering Specification:

Standard: Bedding: IEC – 60502 Polyvinylchoride rated 70ºC

Rated Voltage: Armouring: 600 / 1000 V Double layers of steel tapes are applied helically

Conductor: Sheath: Soft annealed Stranded Copper wire as per Flame retardant polyvinylchloride, black or grey class 2 of IEC 228 colour

Insulation: Minimum bending radius: Polyvinylchloride rated 70oC or 85oC 15 x d (d= overall diameter)

Assembly: Temperature rating: Cores twisted together to form a round +5oC up to + 50oC during operation assembly cable with fillers whenever necessary Packing: On non-returnable wooden drums Colour code: Black cores with white numbers and one green yellow core Technical Information Conductor Nominal Number Nominal Thickness Nominal Approximate Approximate Conductor of Max. DC insulation of sheath overall net UIC – code size No.x Cores Res. At thickness Steel thickness diameter weight dia. o 20 C tape No. x Ohm mm2 No. mm mm mm mm Kg/Km - mm /Km 5 7x 0.52 12.1 0.8 0.2 1.8 14.6 350 CPA-TA105-LU15B

7 7x 0.52 12.1 0.8 0.2 1.8 17.0 430 CPA-TA107-LU15B

10 7x 0.52 12.1 0.8 0.2 1.8 19.3 570 CPA-TA110-LU15B

12 7x 0.52 12.1 0.8 0.2 1.8 19.8 625 CPA-TA112-LU15B

14 7x 0.52 12.1 0.8 0.2 1.8 20.6 690 CPA-TA114-LU15B 1.5 16 7x 0.52 12.1 0.8 0.2 1.8 21.5 800 CPA-TA116-LU15B

19 7x 0.52 12.1 0.8 0.2 1.8 22.5 850 CPA-TA119-LU15B

24 7x 0.52 12.1 0.8 0.2 1.8 25.7 1030 CPA-TA124-LU15B

30 7x 0.52 12.1 0.8 0.2 1.8 27.3 1285 CPA-TA130-LU15B

37 7x 0.52 12.1 0.8 0.2 1.8 28.9 1400 CPA-TA137-LU15B

44 7x 0.52 12.1 0.8 0.2 1.9 31.0 1800 CPA-TA144-LU15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 8 Stranded Copper Conductors PVC Insulation, Steel Tape Armoured, PVC Sheathed

Technical Information Conductor Nominal Number Nominal Nominal Approximate Approximate Conductor Thickness of Max. DC insulation sheath overall net UIC – code size of Cores No.x dia. Res. At thickness thickness diameter weight 20oC Steel tape No. x mm2 No. Ohm /Km mm mm mm mm Kg/Km - mm 5 7x 0.67 7.41 0.8 0.2 1.8 16.2 440 CPA-TA105-UA18B 7 7x 0.67 7.41 0.8 0.2 1.8 17.3 530 CPA-TA107- UA18B 10 7x 0.67 7.41 0.8 0.2 1.8 20.9 710 CPA-TA110- UA18B 12 7x 0.67 7.41 0.8 0.2 1.8 21.5 790 CPA-TA112- UA18B 14 7x 0.67 7.41 0.8 0.2 1.8 22.4 880 CPA-TA114- UA18B 2.5 16 7x 0.67 7.41 0.8 0.2 1.8 23.4 970 CPA-TA116- UA18B 19 7x 0.67 7.41 0.8 0.2 1.8 24.5 1090 CPA-TA119- UA18B 24 7x 0.67 7.41 0.8 0.2 1.8 28.1 1140 CPA-TA124- UA18B 30 7x 0.67 7.41 0.8 0.2 1.9 27.3 1630 CPA-TA130- UA18B 37 7x 0.67 7.41 0.8 0.2 1.9 31.9 1875 CPA-TA137- UA18B 44 7x 0.67 7.41 0.8 0.5 2.1 36.0 2500 CPA-TA144- UA18B 5 7x 0.85 4.61 0.8 0.2 1.8 18.9 660 CPA-TA105-UA21B 7 7x 0.85 4.61 0.8 0.2 1.8 20.3 740 CPA-TA107- UA21B 10 7x 0.85 4.61 0.8 0.2 1.8 24.9 960 CPA-TA110- UA21B 12 7x 0.85 4.61 0.8 0.2 1.8 25.6 1120 CPA-TA112- UA21B 4.0 14 7x 0.85 4.61 0.8 0.2 1.8 26.7 1270 CPA-TA114- UA21B 16 7x 0.85 4.61 0.8 0.2 1.8 28.0 1390 CPA-TA116- UA21B 19 7x 0.85 4.61 0.8 0.2 1.8 29.4 1610 CPA-TA119- UA21B 24 7x 0.85 4.61 0.8 0.2 2.0 34.4 2030 CPA-TA124- UA21B 30 7x 0.85 4.61 0.8 0.2 2.1 36.5 2660 CPA-TA130- UA21B 37 7x 0.85 4.61 0.8 0.5 2.2 39.4 3250 CPA-TA137- UA21B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 9 Stranded Copper Conductors PVC Insulation, Steel Wire Armoured, PVC Sheathed Application: For outdoor and indoor installations in damp and wet locations, laid direct in the ground, where mechanical damages are expected to occur. They are normally used in connecting signaling and control units in industry, in railways, in traffic signals, in thermopower and hydropower stations.

Engineering Specification:

Standard: Bedding: IEC – 60502 Polyvinylchoride rated 70oC

Rated Voltage: Armouring: 600 / 1000 V Single layers of steel wire are applied helically

Conductor: Sheath: Soft annealed stranded copper wire as per Flame retardant polyvinylchloride, black or class 2 of IEC 228 grey colour

Insulation: Minimum bending radius: Polyvinylchloride rated 70oC or 85oC 15 x d (d= overall diameter)

Assembly: Temperature rating: Cores twisted together to form a round +5oC up to + 50oC during operation assembly cable with fillers whenever necessary Packing: On non-returnable wooden drums Colour code: Black cores with white numbers and one green yellow core Technical Information Nominal Number Conductor Nominal Nominal Approximate Approximate Conductor Diameter of Max. DC insulation sheath overall net UIC – code size No.x of steel Cores Res. At thickness thickness diameter weight dia. 20oC wire 2 No. x mm No. mm Ohm/Km mm mm mm mm Kg/Km - 5 7x 0.52 12.1 0.8 0.8 1.8 16.6 500 CPA-TA105-UW15B

7 7x 0.52 12.1 0.8 0.8 1.8 18.0 550 CPA-TA107-UW15B

10 7x 0.52 12.1 0.8 0.8 1.8 21.0 770 CPA-TA110-UW15B

12 7x 0.52 12.1 0.8 1.6 1.8 23.3 1080 CPA-TA112-UW15B

14 7x 0.52 12.1 0.8 1.6 1.8 24.2 1140 CPA-TA114-UW15B

1.5 16 7x 0.52 12.1 0.8 1.6 1.8 25.0 1260 CPA-TA116-UW15B

19 7x 0.52 12.1 0.8 1.6 1.8 26.0 1370 CPA-TA119-UW15B

24 7x 0.52 12.1 0.8 1.6 1.8 28.9 1620 CPA-TA124-UW15B

30 7x 0.52 12.1 0.8 1.6 1.8 31.0 1850 CPA-TA130-UW15B

37 7x 0.52 12.1 0.8 1.6 1.9 34.0 2250 CPA-TA137-UW15B

44 7x 0.52 12.1 0.8 2.0 2.0 37.3 2560 CPA-TA144-UW15B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 10 Stranded Copper Conductors PVC Insulation, Steel Wire Armoured, PVC Sheathed Technical Information

Conductor Nominal Number Nominal Nominal Approximate Approximate Conductor Max. Diameter of insulation sheath overall net UIC – code size No.x DC of steel Cores Res. thickness thickness diameter weight dia. At wire 20oC No. x Ohm mm2 No. mm mm mm mm Kg/Km - mm /Km 5 7x 0.67 7.41 0.8 0.8 1.8 17.8 600 CPA-TA105-UW18B 7 7x 0.67 7.41 0.8 0.8 1.8 19.2 660 CPA-TA107-LW18B 10 7x 0.67 7.41 0.8 1.6 1.8 23.8 1160 CPA-TA110-LW18B 12 7x 0.67 7.41 0.8 1.6 1.8 25.0 1280 CPA-TA112-LW18B 14 7x 0.67 7.41 0.8 1.6 1.8 26.0 1390 CPA-TA114-LW18B 2.5 16 7x 0.67 7.41 0.8 1.6 1.8 27.0 1510 CPA-TA116-UW18B 19 7x 0.67 7.41 0.8 1.6 1.9 28.3 1670 CPA-TA119-LW18B 24 7x 0.67 7.41 0.8 1.6 1.9 31.4 2030 CPA-TA124-LW18B 30 7x 0.67 7.41 0.8 1.6 1.9 34.5 2450 CPA-TA130-LW18B 37 7x 0.67 7.41 0.8 1.6 2.0 37.4 2870 CPA-TA137-LW18B 44 7x 0.67 7.41 0.8 2.0 2.1 40.5 3280 CPA-TA144-LW18B 5 7x 0.85 4.61 1.0 1.6 1.8 20.8 780 CPA-TA105-UW21B 7 7x 0.85 4.61 1.0 1.6 1.8 23.5 1190 CPA-TA107-LW21B 10 7x 0.85 4.61 1.0 1.6 1.8 27.2 1510 CPA-TA110-LW21B 12 7x 0.85 4.61 1.0 1.6 1.8 29.0 1700 CPA-TA112-LW21B 4.0 14 7x 0.85 4.61 1.0 1.6 1.8 30.0 1850 CPA-TA114-LW21B 16 7x 0.85 4.61 1.0 1.6 1.9 31.6 2040 CPA-TA116-LW21B 19 7x 0.85 4.61 1.0 1.6 1.9 33.0 2260 CPA-TA119-UW21B 24 7x 0.85 4.61 1.0 2.0 2.1 38.4 3070 CPA-TA124-LW21B 30 7x 0.85 4.61 1.0 2.0 2.1 41.3 3560 CPA-TA130-LW21B 37 7x 0.85 4.61 1.0 2.0 2.2 43.2 4120 CPA-TA137-LW21B

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

C 11 D.D. LANLAN aandnd Telephone Telepho ne C a Cbablesles D. LAN and Telephone C ables

Unscreened Twisted Pairs (UTP), Data Cable - Category. 5e...... 2 Foil Screened Twisted Pairs (STP), Data Cable - Category. 5e...... 3 Unscreened Twisted Pairs (UTP), Data Cable - Category. 6...... 4 Telephone Cable, PVC Insulated Multipairs ...... 5 Unscreened Twisted Pairs (UTP) Data Cable – Category 5e Application: The cable is used for Local Area Computer Networks mainly in office or business environments. Engineering Specification:

Type: Sheath: UTP- Cat 5e Flame retardant PVC Grey RAL 7032, 5.86mm nominal diameter Standard: TIA / EIA 568 A, ISO / IEC 11801 Pair Colours: One Pair : blue & white / blue Two Pairs : orange & white / orange Conductor: Three Pairs : green & white / green 24 AWG (0.528mm) solid bare conductor Four Pairs : brown & white / brown

Insulation: Bending radius: Solid polyethylene, diameter 0.95mm 8 x O.D during installation UIC Elsewedy LAN Cat. 5e UTP

Pairs: Temperature range during operation: 2 insulated conductors twisted together, Lay +5oC up to + 50oC varied to minimize crosstalk

Assembly: 4 pairs twisted together Electrical Characteristics Characteristic Maximum Near End Minimum Structural Frequency impedance Attenuation Cross talk Return Loss (MHz) (ohms) ( dB /100m @ 20oC ) Minimum (dB) at 100mm 1 100 + 15% 2.1 65 23

4 100 + 15% 4.1 56 23

10 100 + 15% 6.5 50 23

16 100 + 15% 8.3 47 23

20 100 + 15% 9.3 46 23

31.25 100 + 15% 11.7 43 21

62.5 100 + 15% 17.0 38 18

100 100 + 15% 22.0 36 16

125 100 + 15% 25.0 34 16

Pakaging Available in easy – pull boxes of 1000 feet (305m) capacity. This assures the cable will not be damaged during installation due to the “figure 8” internal coiling. It also enables easy, tidy storage before and during installation.

D 2 Foil Screened Twisted Pairs (STP) Data Cable – Category 5e Application: The cable is used for Local Area Computer Networks mainly in electrically noisy office or industrial environments.

Engineering Specification:

Type: Screen: STP- Cat 5e Aluminium polyester tape and 0.5mm plain or tinned copper drain wire Standard: TIA/ EIA 568 A, ISO / IEC 11801 Pair Colours: One Pair : blue & white / blue Two Pairs : orange & white / orange Conductor: Three Pairs : green & white / green 24 AWG (0.528mm) solid bare conductor Four Pairs : brown & white / brown

Insulation: Bending radius: Solid polyethylene, diameter 1.09mm 8 x O.D during installation UIC Elsewedy LAN Cat. 5e STP Pairs: Temperature range during operation: 2 insulated conductors twisted together, lay +5oC up to + 50oC varied to minimize crosstalk

Assembly: 4 pairs twisted together Electrical Characteristics Minimum Structural Frequency Characteristic impedance Maximum Attenuation Near End Cross talk o Return Loss (MHz) (ohms) ( dB /100m @ 20 C ) Minimum (dB) at 100mm

0.772 - 1.8 64 -

1 100 + 15% 2.0 62 23

4 100 + 15% 4.1 53 23

10 100 + 15% 6.5 47 23

16 100 + 15% 8.2 44 23

20 100 + 15% 9.2 42 23

31.25 100 + 15% 11.7 39 21

62.5 100 + 15% 17.0 35 18

100 100 + 15% 22.0 32 16

125 100 + 15% 25.0 32 16

Pakaging Available in easy – pull boxes of 1000 feet (305m) capacity. This assures the cable will not be damaged during installation due to the “figure 8” internal coiling. It also enables easy, tidy storage before and during installation.

D 3 Unscreened Twisted Pairs (UTP) Data Cable – Category 6 Application: The cable is used for Local Area Computer Networks where performance greater than that available from category 5 specification is required.

Engineering Specification:

Type: Sheath: UTP- Cat 6 Flame retardant PVC Grey RAL 7032, 5.94mm nominal diameter Standard: TIA/ EIA 568 A, ISO / IEC 11801 Pair Colours: One Pair : blue & white / blue Two Pairs : orange & white / orange Conductor: Three Pairs : green & white / green 24 AWG (0.54mm) solid bare conductor Four Pairs : brown & white / brown

Insulation: Bending radius: UIC Elsewedy LAN Cat. 5e UTP Solid polyethylene, diameter 0.97mm 8 x O.D during installation

Pairs: Temperature range during operation: 2 insulated conductors twisted together, Lay +5oC up to + 50ohC varied to minimize crosstalk

Assembly: 4 pairs twisted together Electrical Characteristics Characteristic Maximum Near End Minimum Structural Frequency impedance Attenuation Cross talk Return Loss (MHz) o (ohms) ( dB /100m @ 20 C ) Minimum (dB) at 100mm

1 100 ± 15% 1.9 80.0 78.0

4 100 ± 15% 3.8 74.0 70.3

10 100 ± 15% 6.0 68.0 62.2

16 100 ± 15% 7.6 64.0 56.6

20 100 ± 15% 8.6 62.2 53.8

31.25 100 ± 15% 10.9 59.0 48.6

62.5 100 ± 15% 15.8 54.0 39.2

100 100 ± 15% 20.5 50.0 31.2

125 100 ± 15% 20.9 48.0 27.1

200 100 ± 15% 27.0 42.0 15.0

Pakaging Available in easy – pull boxes of 1000 feet (305m) capacity. This assures the cable will not be damaged during installation due to the “figure 8” internal coiling. It also enables easy, tidy storage before and during installation.

D 4 Telephone Cable PVC Insulated Multipairs Application: The cable is used for Indoor installation and interconnection of Transmission, Telephone, Telegraph and Electronic equipment.

Engineering Specification:

Standard: IEC-189 & TC-113

Conductor: Solid, plain / tinned copper.

Insulation: PVC rated 70oC as per IEC 189.2 UIC Elsewedy Telephone Cable Telephone Elsewedy UIC Assembly: Cores are twisted into pairs and pairs twisted together to form a cable core

Sheath: Polyvinylchloride as per IEC 189-2 and rip cord is provided under the sheath for easy stripping

Temperature rating: +5ºC to +50ºC during operation Colour Code of Insulation

No. of A B No. of A B Unit No. Colour of Bindings Pairs Wire Wire Pairs Wire Wire

1 white Blue 11 Black Blue 1 Blue

2 White Orange 12 Black Orange 2 Orange

3 White Green 13 Black Green 3 Green

4 White Brown 14 Black Brown 4 Brown

5 White Grey 15 Black Grey 5 Grey

6 Red Blue 16 Yellow Blue 6 White

7 Red Orange 17 Yellow Orange 7 Red

8 Red Green 18 Yellow Green 8 Black

9 Red Brown 19 Yellow Brown 9 Yellow

10 Red Grey 20 Yellow Grey 10 Violet

Pakaging Cables supplied on coils of (200m) or in non-returnable wooden drums.

D 5 Telephone Cable PVC Insulated Multipairs Technical Information

Number Conductor Nominal Nominal Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC - code size No.x dia. pairs 20oC thickness thickness diameter weight mm2 No. No. x mm Ohm /Km mm mm Mm Kg/Km - 1 1x0.4 153.0 0.15 0.6 3.0 12 TEL04-1U 2 1x0.4 153.0 0.15 0.6 4.1 19 TEL04-2U 3 1x0.4 153.0 0.15 0.6 4.2 23 TEL04-3U 4 1x0.4 153.0 0.15 0.6 4.6 28 TEL04-4U 5 1x0.4 153.0 0.15 0.6 5.0 33 TEL04-5U 6 1x0.4 153.0 0.15 0.7 5.6 40 TEL04-6U 7 1x0.4 153.0 0.15 0.7 5.9 44 TEL04-7U 10 1x0.4 153.0 0.15 0.7 6.7 57 TEL04-10U 15 1x0.4 153.0 0.15 0.7 7.9 79 TEL04-15U 20 1x0.4 153.0 0.15 0.8 9.1 104 TEL04-20U 0.4 25 1x0.4 153.0 0.15 0.8 10.0 125 TEL04-25U 30 1x0.4 153.0 0.15 0.8 10.7 143 TEL04-30U 40 1x0.4 153.0 0.15 0.9 12.4 191 TEL04-40U 50 1x0.4 153.0 0.15 0.9 13.6 230 TEL04-50U 60 1x0.4 153.0 0.15 0.9 14.7 270 TEL04-60U 80 1x0.4 153.0 0.15 1.0 16.9 355 TEL04-80U 100 1x0.4 153.0 0.15 1.0 18.6 430 TEL04-100U 200 1x0.4 153.0 0.15 1.4 28.0 1012 TEL04-200U 300 1x0.4 153.0 0.15 1.5 33.4 1486 TEL04-300U 400 1x0.4 153.0 0.15 1.6 38.4 1952 TEL04-400U 1 1x0.5 97.8 0.15 0.6 3.4 16 TEL05-1U 2 1x0.5 97.8 0.15 0.6 4.8 6 TEL05-2U 3 1x0.5 97.8 0.15 0.6 4.9 32 TEL05-3U 4 1x0.5 97.8 0.15 0.6 5.4 38 TEL05-4U 5 1x0.5 97.8 0.15 0.6 5.9 45 TEL05-5U 6 1x0.5 97.8 0.15 0.7 6.6 56 TEL05-6U 7 1x0.5 97.8 0.15 0.7 7.0 63 TEL05-7U 10 1x0.5 97.8 0.15 0.7 8.0 82 TEL05-10U 15 1x0.5 97.8 0.15 0.7 9.5 114 TEL05-15U 0.5 20 1x0.5 97.8 0.15 0.8 10.9 150 TEL05-20U 25 1x0.5 97.8 0.15 0.8 12.0 180 TEL05-25U 30 1x0.5 97.8 0.15 0.9 13.2 215 TEL05-30U 40 1x0.5 97.8 0.15 0.9 14.9 280 TEL05-40U 50 1x0.5 97.8 0.15 0.9 16.5 340 TEL05-50U 60 1x0.5 97.8 0.15 0.9 17.9 400 TEL05-60U 80 1x0.5 97.8 0.15 1.0 20.5 520 TEL05-80U 100 1x0.5 97.8 0.15 1.0 22.7 640 TEL05-100U 200 1x0.5 97.8 0.15 1.5 30.6 1350 TEL05-200U 300 1x0.5 97.8 0.15 1.6 37.0 2000 TEL05-300U

D 6 Telephone Cable PVC Insulated Multipairs Technical Information

Conductor Number Minimum Minimum Approximate Approximate Conductor of Max. DC Res. At insulation sheath overall net UIC - code size No.x dia. pairs 20oC thickness thickness diameter weight

Mm2 No. No. x mm Ohm /Km mm mm Mm Kg/Km - 1 1x0.6 67.9 0.15 0.6 3.6 19 TEL06-1U 2 1x0.6 67.9 0.15 0.6 5.1 31 TEL06-2U 3 1x0.6 67.9 0.15 0.6 5.2 38 TEL06-3U 4 1x0.6 67.9 0.15 0.6 5.8 47 TEL06-4U 5 1x0.6 67.9 0.15 0.6 6.4 57 TEL06-5U 6 1x0.6 67.9 0.15 0.7 7.1 69 TEL06-6U 7 1x0.6 67.9 0.15 0.7 8.7 77 TEL06-7U 10 1x0.6 67.9 0.15 0.7 10.5 103 TEL06-10U 15 1x0.6 67.9 0.15 0.8 12.0 150 TEL06-15U 20 1x0.6 67.9 0.15 0.9 13.2 195 TEL06-20U 0.6 25 1x0.6 67.9 0.15 0.9 14.3 235 TEL06-25U 30 1x0.6 67.9 0.15 0.9 16.2 275 TEL06-30U 40 1x0.6 67.9 0.15 0.9 17.9 355 TEL06-40U 50 1x0.6 67.9 0.15 0.9 19.6 430 TEL06-50U 60 1x0.6 67.9 0.15 1.0 22.3 515 TEL06-60U 80 1x0.6 67.9 0.15 1.0 25.1 670 TEL06-80U 100 1x0.6 67.9 0.15 1.2 26.0 845 TEL06-100U 150 1x0.6 67.9 0.15 1.4 26.7 1240 TEL06-150U 200 1x0.6 67.9 0.15 1.5 30.71 1260 TEL06-200U 250 1x0.6 67.9 0.15 1.6 34.0 2000 TEL06-250U 1 1x0.8 37.5 0.25 0.7 6.4 30 TEL085-1U 2 1x0.8 37.5 0.25 0.7 6.5 50 TEL08-2U 3 1x0.8 37.5 0.25 0.7 7.3 62 TEL08-3U 4 1x0.8 37.5 0.25 0.7 7.9 78 TEL08-4U 5 1x0.8 37.5 0.25 0.7 9.0 91 TEL08-5U 6 1x0.8 37.5 0.25 0.9 9.5 115 TEL08-6U 7 1x0.8 37.5 0.25 0.9 11.0 128 TEL08-7U 10 1x0.8 37.5 0.25 0.9 13.1 171 TEL08-10U 0.8 15 1x0.8 37.5 0.25 0.9 14.8 240 TEL08-15U 20 1x0.8 37.5 0.25 0.9 16.5 310 TEL08-20U 25 1x0.8 37.5 0.25 1.0 17.9 385 TEL08-25U 30 1x0.8 37.5 0.25 1.0 20.3 450 TEL08-30U 40 1x0.8 37.5 0.25 1.0 22.9 580 TEL08-40U 50 1x0.8 37.5 0.25 1.2 24.8 735 TEL08-50U 60 1x0.8 37.5 0.25 1.2 28.7 865 TEL08-60U 80 1x0.8 37.5 0.25 1.4 31.7 1150 TEL08-80U 100 1x0.8 37.5 0.25 1.4 32.5 1410 TEL08-100U • The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

D 7 E. Coaxial Cables E. Coaxial Cables

MATV Cables …………………………………………………………………...... …...... 2 RG Cables ………………………………………...... ……………………….…….. 4

E 1 Coaxial Cables MATV Cables Application: TV patented coaxial cables for satellite and digital installations.

Engineering Specification:

Conductor: Solid plain copper

Insulation: Cellular polyethylene

Shield: Aluminium polyester with tinned or plain copper braid

Jacket: UIC Elsewedy Coaxial Cables 75 ohms Polyvinylchloride, white or black colour

Packing: Available in easy – pull boxes 100m or 500m on wooden drums

Technical Information Type: RG - 59 / U MATV Nominal Conductor Insulation Shield type Outer Nominal Nominal Nominal Attenuation Velocity of Diameter Diameter & Coverage Diameter Impedance Capacitance At 20oC Propag. mm mm % mm Ohms PF / m % MHz dB / 100 m

0.81 3.71 100% Al /PET 6.16 75 + 2% 53 82 100 8.2

Tape + 40% 200 11.5

T. CU braid 400 16.1

700 21.3

Type: RG - 11 / U MATV Nominal Conductor Insulation Shield type Outer Nominal Nominal Nominal Attenuation Velocity of Diameter Diameter & Coverage Diameter Impedance Capacitance At 20oC Propag. mm mm % mm Ohms PF / m % MHz dB / 100 m

1.63 7.25 100% Al /PET 10.3 75 + 2% 53 82 100 3.9

Tape + 40% 200 5.6

T. CU braid 400 7.9

700 11.5

E 2 Coaxial Cables MATV Cables

Technical Information Type: RG - 6 / U MATV Nominal Conductor Insulation Shield type Outer Nominal Nominal Nominal Attenuation Velocity of Diameter Diameter & Coverage Diameter Impedance Capacitance At 20oC Propag. mm mm % mm Ohms PF / m % MHz dB / 100m

1.02 4.59 100% Al /PET 7.0 75 + 2% 53 82 100 6.6

Tape + 40% 200 9.2

T. CU braid 400 13.1

700 17.4

Type: CF -160 MATV Nominal Conductor Insulation Shield type Outer Nominal Nominal Nominal Attenuation Velocity of Diameter Diameter & Coverage Diameter Impedance Capacitance At 20oC Propag. Mm mm % mm Ohms PF / m % MHz dB / 100 m

1.14 5.1 100% Al /PET 7.0 75 + 2% 53 82 100 6

Tape + 70% 300 9

T. CU braid 500 13

800 16

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

E 3 Coaxial Cables RG Cables Application: Cables used for transmitting and receiving high frequency signals in radio frequency devices and connections.

Engineering Specification:

Conductor: Solid or stranded plain / tinned copper

Insulation: Solid polyethylene

Shield: Plain or tinned copper braid UIC Elsewedy Coaxial Cables 50 ohms Jacket: Polyvinylchloride, white or black colour

Packing: Available in easy – pull boxes 100m or 500m on wooden drums

Technical Information Type: RG - 58 / U Shield Nominal Conductor Insulation type Outer Nominal Nominal Nominal Attenuation Velocity of Mat. /Const. Diameter & Diameter Impedance Capacitance At 20oC Propag. Coverage mm mm % mm Ohms PF / m % MHz dB / 100 m

CU / 1x0.82 2.95 96% 4.9 53 + 2% 93 66 100 14.8

T. CU braid 200 22.3

400 32.8

700 45.9

E 4 Coaxial Cables RG Cables

Type: RG -216 Nominal Conductor Insulation Shield type Outer Nominal Nominal Nominal Attenuation Velocity of Mat. /Const. Diameter & Coverage Diameter Impedance Capacitance At 20oC Propag. Mm mm % mm Ohms PF / m % MHz dB / 100 m

CU / 7 x 0.4 7.25 95% 10.8 75 + 2% 67.3 66 100 6.6

2 CU braid 200 9.5

400 13.8

700 19.0

Type: RG - 8 / U Nominal Conductor Insulation Shield type Outer Nominal Nominal Nominal Attenuation Velocity of Mat. /Const. Diameter & Coverage Diameter Impedance Capacitance At 20oC Propag. Mm mm % mm Ohms PF / m % MHz dB / 100 m

CU / 7 x 0.74 7.16 97% 10.29 52 + 2% 96.8 66 100 6.2

CU braid 200 8.9

400 13.4

700 26.2

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

E 5 F. Automotive Wires F. Automotive Wires

PVC Insulation …………………………………………………………...... …………….………. 2 Heat – Resistant PVC Insulation…………….…………………………………....……………...... 3 Heat – Pressure Resistant PVC Insulation …..………………………………….……..……...... 4 Cold – Resistant PVC Insulation …………………………………...... ……...…….……...... 5 Concentric Conductors with PVC Insulation …..………………………………….……..……...... 6 PVC Thin Insulation ……………………………………………………………………………...... 7 Automotive Wires PVC Insulation Application: This wire is used in the manufacture of electrical harnesses for cars and other automotive products. Engineering Specification:

Conductor: Soft annealed stranded fine wires according to DIN ISO 6722, part 3

Insulation: Polyvinylchloride, according to DIN ISO 6722, part 2, class A

Colour coding : Two colours are marked by two diametrically opposed longitudinal stripes

Packing: Cables are packed in carton boxes

Temperature range: -40oC up to + to 90 oC Technical Information Conductor Nominal Approximate Approximate Conductor Approx. Max. DC Res. At insulation overall net UIC – code size No.x dia. Diameter 20oC thickness diameter weight

mm2 No. x mm mm Ohm /Km mm mm Kg/Km -

0.5 16 x 0.21 1.0 37.1 0.6 2.2 9 CHC-F0101-AU050

0.75 24 x 0.21 1.2 24.7 0.6 2.4 12 CHC-F0101-AU080

1.0 32 x 0.21 1.35 18.5 0.6 2.6 15 CHC-F0101-AU120

1.5 30 x 0.26 1.7 12.7 0.6 2.9 20 CHC-F0101-AU150

2 40 x 0.26 2.0 9.42 0.6 3.2 26 CHC-F0101-AU170

2.5 50 x 0.26 2.2 7.6 0.7 3.6 32 CHC-F0101-AU180

3 60 x 0.26 2.5 6.0 0.7 3.9 37 CHC-F0101-AU180

4 56 x 0.31 2.75 4.71 0.8 4.4 49 CHC-F0101-AU210

6 84 x 0.31 3.3 3.14 0.8 4.9 68 CHC-F0101-AU230

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

F 2 Automotive Wires Heat – Resistant PVC Insulation Application: This wire is used in the manufacture of electrical harnesses for cars and other automotive products. Engineering Specification:

Conductor: Soft annealed stranded fine wires according to DIN ISO 6722, part 3

Insulation: Heat – resistant polyvinylchloride, according to DIN ISO 6722, part 2, class B

Colour coding : Two colours are marked by two diametrically opposed longitudinal stripes

Packing: Cables are packed in carton boxes

Temperature range: -40oC up to + to 105 oC

Technical Information Conductor Nominal Approximate Approximate Conductor Approx. Max. DC Res. At insulation overall net UIC – code size No.x dia. Diameter 20oC thickness diameter weight mm2 No. x mm mm Ohm /Km mm mm Kg/Km -

0.5 16 x 0.21 1.0 37.1 0.6 2.2 9 CSC-F0101-AU050

0.75 24 x 0.21 1.2 24.7 0.6 2.4 11 CSC-F0101-AU080

1.0 32 x 0.21 1.35 18.5 0.6 2.6 14 CSC-F0101-AU120

1.5 30 x 0.26 1.7 12.7 0.6 2.9 19 CSC-F0101-AU150

2.5 50 x 0.26 2.2 7.6 0.7 3.6 31 CSC-F0101-AU180

4 56 x 0.31 2.75 4.71 0.8 4.4 49 CSC-F0101-AU210

6 84 x 0.31 3.3 3.14 0.8 4.9 68 CSC-F0101-AU230

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

F 3 Automotive Wires Heat – Pressure Resistant PVC Insulation Application: This wire is used in the manufacture of electrical harness for cars and other automotive products. Engineering Specification:

Conductor: Soft annealed stranded fine wires according to DIN ISO 6722, part 3

Insulation: Heat – resistant polyvinylchloride, according to DIN ISO 6722, part 2 class B (hot pressure resistance test at 120oC)

Colour coding : Two colours are marked by two diametrically opposed longitudinal stripes

Packing: Cables are packed in carton boxes

Temperature range: -20oC up to + to 125 oC

Technical Information Conductor Nominal Approximate Approximate Conductor Approx. Max. DC Res. At insulation overall net UIC – code size No.x dia. Diameter 20oC thickness diameter weight mm2 No. x mm mm Ohm /Km mm mm Kg/Km -

0.5 16 x 0.21 1.0 37.1 0.6 2.2 9 CZC-F0101-AU050

0.75 24 x 0.21 1.2 24.7 0.6 2.4 11 CZC-F0101-AU080

1.0 32 x 0.21 1.35 18.5 0.6 2.6 14 CZC-F0101-AU120

1.5 30 x 0.26 1.7 12.7 0.6 2.9 19 CZC-F0101-AU150

2.5 50 x 0.26 2.2 7.6 0.7 3.6 30 CZC-F0101-AU180

3 60 x 0.26 2.5 6.21 0.7 3.9 36 CZC-F0101-AU190

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

F 4 Automotive Wires Cold – Resistant PVC Insulation Application: This wire is used in the manufacture of electrical harness for cars and other automotive products. Engineering Specification:

Conductor: Soft annealed stranded super fine wires

Insulation: Cold- resistant polyvinylchloride, according to DIN ISO 6722, part 2, class A. (Cold pressure resistance test at 120oC)

Colour coding : Two colours are marked by two diametrically opposed longitudinal stripes

Packing: Cables are packed in carton boxes

Temperature range: -40oC up to + to 90 oC

Technical Information Conductor Nominal Approximate Approximate Conductor Approx. Max. DC Res. At insulation overall net UIC – code size No.x dia. Diameter 20oC thickness diameter weight mm2 No. x mm Mm Ohm /Km mm mm Kg/Km -

0.5 28 x 0.16 1.1 37.7 0.6 2.3 9 CFC-F0101-AU050

0.75 24 x 0.16 1.3 25.1 0.6 2.5 12 CFC-F0101-AU080

1.0 57 x 0.16 0.5 18.8 0.6 2.7 15 CFC-F0101-AU120

1.5 84 x 0.16 1.8 12.4 0.6 3.0 20 CFC-F0101-AU150

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

F 5 Automotive Wires Concentric Conductors with PVC Insulation Application: This wire is used in the manufacture of electrical harnesses for cars and other automotive products. Engineering Specification:

Conductor: Concentric stranded copper conductor according to DIN ISO 72551, part 6, type A

Insulation: Polyvinylchloride, according to DIN ISO 72551, part 5

Colour coding : Two colours are marked by two diametrically opposed longitudinal stripes

Packing: Cables are packed in carton boxes

Temperature range: -40oC up to + to 105 oC

Technical Information Conductor Nominal Approximate Approximate Conductor Approx. Max. DC Res. At insulation overall net UIC – code size No.x dia. Diameter 20oC thickness diameter weight

mm2 No. x mm mm Ohm /Km mm mm Kg/Km -

0.35 7 x 0.26 0.8 52.0 0.2 1.3 4.5 CVE-F0101-AU030

0.5 19 x 0.19 1.0 37.1 0.22 1.6 6.6 CVE-F0101-AU050

0.75 19 x 0.23 1.2 24.7 0.24 1.9 9.0 CVE-F0101-AU080

1.0 19 x 0.32 1.35 18.5 0.24 2.1 11.0 CVE-F0101-AU120

1.5 19 x 0.32 1.7 12.7 0.24 2.4 16.0 CVE-F0101-AU150

2.0 19 x 0.37 2.0 9.42 0.24 2.6 22.5 CVE-F0101-AU170

2.5 19 x 0.41 2.2 7.6 0.28 3.0 26.0 CVE-F0101-AU180

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

F 6 Automotive Wires PVC Thin Insulation Application: This wire is used in the manufacture of electrical harnesses for cars and other automotive products. Engineering Specification:

Conductor: Fine wires stranded copper conductor according to DIN ISO 72551, part 6, type B.

Insulation: Polyvinylchloride, according to DIN ISO 72551, part 5

Colour coding: Two colours are marked by two diametrically opposed longitudinal stripes

Packing: Cables are packed in carton boxes

Temperature range: -40oC up to + to 105 oC Technical Information

Conductor Details Minimum Approximate Minimum Approximate Conductor Max. DC insulation overall Concent. net UIC – code size Approx. No.x dia. Res. At thickness diameter Factor weight Diameter 20oC mm2 No. x mm mm Ohm /Km mm mm % Kg/Km -

0.35 12 x 0.21 0.9 52.0 0.2 1.4 55 4.5 CQE-F0101-AU030

0.5 16 x 0.21 1.0 37.1 0.22 1.6 55 6.6 CQE-F0101-AU050

0.75 24 x 0.21 1.2 24.7 0.24 1.9 55 9.0 CQE-F0101-AU080

1.0 32 x 0.21 1.35 18.5 0.24 2.1 55 11.0 CQE-F0101-AU120

1.5 30 x 0.26 1.7 12.7 0.24 2.4 55 16.0 CQE-F0101-AU150

2.0 30 x 0.31 1.9 9.31 0.24 2.6 55 22.5 CQE-F0101-AU170

2.5 50 x 0.26 2.2 7.6 0.28 3.0 55 26.0 CQE-F0101-AU180

3 45 x 0.31 2.4 6.21 0.28 3.2 55 32.5 CQE-F0101-AU190

4 56 x 0.31 2.75 4.7 0.32 3.7 55 42.0 CQE-F0101-AU210

6 84 x 0.31 3.30 3.10 0.32 4.3 55 61.0 CQE-F0101-AU230

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

F 7 G. Appliance Cables and Cords G. Appliance Cables and Cords

Appliance Cables, Flexible PVC Cables, HO5VV-F ...... 2 Appliance Cords, Flat Cords ...... 4 Appliance Cords, Round Cords with Double Earthing System ...... 5 High Resolution Pls Flexible PVC Cables HO5VV-F Application: These cables can be used for domestic cooking and heating appliances provided that the cable does not come into contract with the heating elements. Engineering Specification: Three cores: Standard: Green / Yellow, Blue, Brown BS 6500 Four Cores: Rated Voltage: Green / Yellow, Black, Blue, Brown. 300 / 500 V Assembly: Cores twisted together to form a round cable Conductor: UIC Elsewedy H05VV-F 300 500 V UIC Elsewedy H05VV-F Stranded plain annealed copper as per Sheath: BS - 6360 PVC type TM-2 as per BS6746 - white colour

Insulation: Temperature rating: PVC type TI – 2 as per BS - 6746 +5oC up to + 70oC

Colour code: Blue, Brown Technical Information Conductor Nominal Nominal Approximate Approximate Conductor Max. DC Res. At insulation Sheath overall net UIC – code size No.x dia. 20oC thickness Thickness diameter weight

mm2 No. x mm Ohm /Km mm mm mm Kg/Km -

2 x 0.75 24 x 0.2 26.4 0.6 0.8 6.5 61 HO5VV-F2-2*0.75R

2 x 1.0 32 x 0.2 19.5 0.6 0.8 6.8 70 HO5VV-F2-2*1.0R

2 x 1.5 30 x 0.25 13.3 0.7 0.8 7.7 91 HO5VV-F2-2*1.5R

2 x 2.5 50 x 0.25 7.98 0.8 1.0 9.4 139 HO5VV-F2-2*2.5R

2 x 4 56 x 0.3 4.95 0.8 1.1 10.7 192 HO5VV-F2-2*4.0R

3 x 0.75 24 x 0.2 26.4 0.6 0.8 6.9 73 HO5VV-F2-3*0.75R

3 x 1.00 32 x 0.2 19.5 0.6 0.8 7.2 85 HO5VV-F2-3*1.0R

3 x 1.5 30 x 0.25 13.3 0.7 0.9 8.4 114 HO5VV-F2-3*1.5R

3 x 2.5 50 x 0.25 7.98 0.8 1.1 10.2 175 HO5VV-F2-3*2.5R

3 x 4 56 x 0.3 4.95 0.8 1.2 11.6 244 HO5VV-F2-3*4.0R

4 x 0.75 24 x 0.2 26.4 0.6 0.9 7.7 91 HO5VV-F2-4*0.75R

4 x 1.0 32 x 0.2 19.5 0.6 0.9 8.1 106 HO5VV-F2-4*1.0R

4 x 1.5 30 x 0.25 13.3 0.7 1.0 9.3 142 HO5VV-F2-4*1.5R

4 x 2.5 50 x 0.25 7.98 0.8 1.1 11.1 211 HO5VV-F2-4*2. 5R

4 x 4 56 x 0.3 4.95 0.8 1.2 12.6 297 HO5VV-F2-4*4.0R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

G 3 Flexible PVC Cables HO3VV-F Application: These cables are useful in domestic premises, kitchens, offices or light duties for light portable appliances. Engineering Specification: Three cores: Standard: Green / Yellow, Blue, Brown BS 6500 Four Cores: Rated Voltage: Green / Yellow, Black, Blue, Brown 300 / 300 V Assembly: Cores twisted together to form a round cable Conductor: For flat cables, two cores re laid parallel Stranded plain annealed copper as per BS

- 6360 300 V UIC Elsewedy H05VV-F Sheath: PVC type TM-2 as per BS6746 - white colour Insulation: PVC type TI – 2 as per BS - 6746 Temperature rating: -5oC up to + 70oC Colour code: Blue, Brown

Technical Information Conductor Nominal Nominal Approximate Conductor Approximate Max. DC Res. insulation Sheath net UIC – code size No.x dia. overall diameter At 20oC thickness Thickness weight mm2 No. x mm Ohm /Km mm mm mm Kg/Km -

2 x 0.5 16 x 0.2 39.0 0.5 0.6 3.6 x 6.0 30 HO3VV-F2-2* 0.5F

2 x 0.5 16 x 0.2 39.0 0.5 0.6 5.2 40 HO3VV-F2- 2* 0.5R

2 x 0.75 24 x 0.2 26.4 0.5 0.6 3.9 x 6.4 40 HO3VV-F2- 2* 0.75F

2 x 0.75 24 x 0.2 26.4 0.5 0.6 5.7 49 HO3VV-F2- 2* 0.75R

3 x 0.5 16 x 0.2 39.0 0.5 0.6 5.6 48 HO3VV-F2- 3* 0.5R

3 x 0.75 24 x 0.2 26.4 0.5 0.6 6.0 60 HO3VV-F2- 3* 0.75R

4 x 0.5 16 x 0.2 39.0 0.5 0.6 6.1 58 HO3VV-F2- 4* 0.5R

4 x 0.75 24 x 0.2 26.4 0.5 0.6 6.6 72 HO3VV-F2- 4* 0.75R

• The above data are approximate and subject to normal manufacturing tolerance. • Other types can be provided on specific request.

G 4 Flat Cords:

Suitable Cables: HO3VV-F : 2 x 0.75 HO5VV-F : 2 x 0.75 HO5VV-F : 2 x 1.0

Group: PVC Pug for Safety Class II

Voltage rating 300 / 300 V & 300 / 500 V only allowed for double insulated appliances

Description: Straight flat plug without earthing contract

Material : Glass – reinforced polyamide, black or white colour

Permitted current rating: 2.5 Amps AC or 10 Amps AC

Permitted Voltage: 250 V AC Pins: 4.0 mm Ø solid metal Pins, nickel – plated

G 5 Round Cords with Double Earthing System

Suitable Cables: HO5VV-F : 3 G 0.75 HO5VV-F : 3 G 1.0 HO5VV-F : 3 G 1.5

Group: PVC Pug for Safety Class I

Voltage rating 300 / 500 V

Description: 2- pin angled plug with double earthing system

Material : PBTP 30% glass – reinforced, anthracite black or white colour

Permitted current rating: 10 / 16 Amps AC

Pins: 4.8 mm Ø solid metal Pins, nickel – plated

G 6 Round Cords with Double Earthing System

Suitable Cables: HO3VV-F : 3 G 0.75 HO5VV-F : 3 G 0.75 HO5VV-F : 3 G 1.0

Group: PVC Plug for Safety Class I

Voltage rating: 300 / 300 V & 300 / 500 V

Description: 2 - pin angled plug with lateral earthing system Material : PBTP 30% glass – reinforced, anthracite black or white colour Permitted current rating: 10 / 16 Amps AC

Pins: 4.8 mm Ø solid metal Pins, nickel – plated

G 7 H. Technical Information H. Technical Information Technical Information

DC resistance of conductor: DC resistance per unit length of the conductor at another conductor temperature t is given by:

R=RO [1+ 20 (t-20OC)]

Where: R = DC resistance at temperature to C Ω/Km Ro = DC resistance at temperature 20oC Ω/Km t = conductor temperature oC 20 = temperature coefficient at 20oC 1/oC

AC Resistance of Conductor: To calculate the AC resistance of the conductor at its operating temperature the following formula is used:

Rac = R ( 1 + Kp + Ks)

Where:

KP and KS are proximity effect and skin effect factors

Inductance: Self mutal inductance is defined as follows:

L = K + 0.2 Ln 25 d

Where: L = Inductance in mH / Km K = A constant depending on the number of wires in the conductor d = Conductor diameter in mm n = Axial spacing between cables in trefoil formation in mm = 1.26 x axial spacing between cables in flat formation in mm

H 2 Technical Information

Capacitance: The mutual capacitance of the pairs or adjacent cores shall not exceed a maximum of 250 PF/m at a frequency of 1KHz 1- Mutual capacitance of unshielded twisted pair 7.218 C = log 1.3D fd

2- Mutual capacitance of shielded twisted pair 21.14 C = log 1.2D fd

3- Mutual capacitance of overall shielded & cables

9.515 C = log 1.5D fd

Where: C : Mutual Capacitance In PF/m ε : Dielectric constant of insulation material D : Diameter over insulation in mm d : Diameter over conductor in mm

L / R ratio: The L / R ratio for adjacent cores shall not exceed the following maximum value:

Conductor Maximum L/R ratio mm2 µH / Ω 0.5 25 0.75 25 1.5 40

H 3 Technical Information

Impedance Zo (ohms): 310 1- Unshielded twisted pair : Zo = C

276 1.2D 2- Shielded twisted pair : Zo = log f(d)

347 Zo = log 1.5D 3- Overall shield & cabled : f(d) Where: C : Mutual Capacitance In PF/m ε : Dielectric constant of insulation material f : Stranding factor depend on no. of wires in conductor D : Diameter over insulation in mm d : Diameter over conductor in mm

Attenuation: The power loss in an electrical system, in cables, generally expressed in decibels (dB) per unit length

RGW Attenuation : (A) = 86.8 2

Where: A: Attenuation in dB per 100 ft R: Resistance (AC) G: Conductance W: 2∏ f (f= test frequency MHz)

Velocity of Propagation: The speed of an electrical signal down a length of cable compared to speed in free space expressed as a percent. It is inversely proportional to the dielectric constant. Lowering the dielectric constant. Lowering the dielectric constant increases the velocity 1 1 Vp = or Vp = Lc

Where: E : Dielectric constant L: Inductance C: Capacitance

Dielectric medium or Vp material (%) Air 100.0 Solid polyethylene 65.9 Foamed polyethylene 80.0 PVC 45.0

H 4 Technical Information

Fire Resistant cables: A cable can be described as fire resistant when it complies with the severe test in IEC 331 in which the middle portion of a sample of cable 1200 mm long is supported by two metal rings 300 mm apart and exposed to the flame from a tube type gas burner at 750oC. Simultaneously the rated voltage of the cable is applied continuously throughout the test period. Furthermore, not less than 12 hours after the flame has been extinguished, the cable is reenergized. No electrical failure must occur under these conditions.

Halogen Free Material: What are Halogens? Halogens are salts of the elements Fluorine, Chlorine, Bromine and lodine. Fluorine and chlorine are important in cable design. For example; Flourine, Chlorine and Bromine are common components of flame protection additives.

When is a cable Halogen–free? The burning behavior of cables is very important for the safety of buildings and also in control plants. Consequently the following points are important: • Behavior under flame influence ie. the inflammability as the propagation of fire. • Development of smoke density (darkening of emergency exits, hindrance of the fire fighters). Cables produced of non halogen – free materials such as those with chlorine in the molecule – chain : polyvinylchloride (PVC), chloroprene rubber (CR), chlorinated polyethylene (CM), have a better behavior in case of fire. These are barely combustible or not flammable and self-extinguishing, in case of fire molecules of Chlorine (or Fluorine) are released which hinder the access of oxygen at the fire location and hence suffocate the flame. The disadvantage of these materials is that the released Chlorine (or Flourine) atoms combine with hydrogen which is decomposed from the plastic material as wel as hydro choleric acid or hydroflouoric acid from the existing air. These compounds are extremely corrosive and toxic in consequence, damage by corrosion may be higher than the damage caused by fire. Halogen-free cables contain no halogens, le. the insulation and sheath materials of these cables are composed of polymers of pure hydrocarbons. Burning these materials, produce no corrosive compounds or toxic gases, only water vapor and carbon dioxide gas. For maximum security halogen free cable must be hardly flammable and self-extinguishing . This is achieved by using special polymer compounds, containing high percentages of flame protective materials.

Application: Halogen-free cable are increasingly specified for public buildings and areas where large numbers of people may be present.

H 5 Technical Information

LAN Cables: The necessity to communicate through digital information, to share data, to reach calculation – resources and to share costly devices has encourages the development of local area networks. A local area network (LAN) is a computer network linking users in a small area. Generally, a local area network connects users located either in the same office, or at the same floor, or in the same building. The success of local area networks is due to their ability to satisfy communication needs at a reasonable price. Compatibility is a critical element. Local area networks require high–speed channels for data–transmission, permitting the transfer of large blocks of data, images, and video-signals. The technology used in local networks can reach a transmission rate which is higher that 100 Mbps, Ie. higher than that of traditional direct connections. Moreover, the traditionally low transfer – capacity of public telecommunications is increasing therefore the distinction between direct connection, local area networks and wide area networks is going to loose significance, at least as far as transmission – capacity is concerned. The transmission media is the cable. Common media are phone-pairs, coaxial cables and purpose designed LAN cables which are essentially extremely high performance telephone pairs, sometimes provided with shielding. This kind of shielded cable is more immune to electrical interference and permits high speed transmission over longer distances. Pairs are still the most versatile media for transmission and are often the best choice for new network installations.

Attenuation: The reduction in a transmitted signal as it passes through wires or equipment in an electrical circuit.

Maximum attenuation values of Cat 5

Frequency Maximum attenuation (MHz) dB 0.1 N / A 1.0 2.5 4.0 4.8 10.0 7.5 16.0 9.4 20.0 10.5 31.25 13.1 62.5 18.4 100.0 23.2

Characteristic Impedance: The nominal differential characteristic impedance of a cabling link shall be 100Ω at frequencies between 1 MHz and the highest specified frequency for the cabling class. The tolerance of the characteristic impedance in a given link shall not exceed the chosen nominal impedance by more than + 15Ω from 1Mhz up to the highest specified frequency for the class.

H 6 Technical Information

Near end crosstalk loss (Next): The near–end crosstalk loss of a link shall meet or exceed the values shown in table below, and shall be consistent with the design values of cable length and cabling materials used.

Maximum next loss of Cat 5

Frequency Maximum attenuation (MHz) dB 1.0 54 4.0 45 10.0 39 16.0 36 20.0 35 31.25 32 62.5 27 100 24

Attenuation to crosstalk loss ration (ASR): This is the difference between the crosstalk and the attenuation of the link in dB.

ACR(dB) = an (dB)- a(dB).

Return loss: The return loss of the cabling, measured at any interface, shall meet or exceed the values shown in the table below:

Frequency Maximum attenuation (MHz) dB 1< F < 10 18 10< F < 16 15 16< F < 20 15 20< F < 100 10

H 7 Technical Information

Coaxial Cable : A cable consisting of two cylindrical with a common axis, separated by a dielectric

Electrical Parameters:

138 D 1- Characteristic Impedance: Zo = log d

100% 2- Velocity of Propagation: Vp =

24.148 3- Capacitance: C = PF / m log D d

4- Inductance: L = 0.459 log D H / m d

5- Braiding Details:

2 (D+e)P Braid angle: = tan-1 C Degrees

0.394(c) tan Braid picks per cm: P = 2 M

r Braid resistance: R = /km n (C) (cos )

Where:

D = Diameter under shield in mm n = number of wires in one carrier d = conductor diameter in mm M = D + build of braid on one shield wall in mm ε = dielectric constant of insulation e = diameter of each wire in mm = 1.56 cellular polyethylene R = DC resistance of the braid in ohm/km = 2.26 solid polyethylene r = DC resistance of each wire in ohm/km C= number of carriers p = picks per cm

H 8 Technical Information

Packing:

1- LAN Cable:

Available in easy – pull boxes of 1000 feet (305m) capacity. This assures the cable will not be damaged during installation due to the “figure 8” coiling. It also enables easy, tidy storage before and during installation.

2 - Coaxial Cable: Available in easy – pull boxes of 100 m or 500m on wooden drum.

3 - Telephone Cable: Cables supplied on coils of (200m) or in non-returnable wooden drums.

4 - Automotive wires: Wires are packed in Carton boxes which reduces storage area & cost. Boxes may be delivered individually or as a solid cube on wooden pallet.

H 9 Technical Information

5- Instrumentation, Fire Resistant and Control Cables:

International practice is to supply cables on wooden drums. At the customers request we will also supply on steel drums for improved on-site performance and handling.

Drum Dimensions

D D d1 B1 B2 W1 W2

600 300 85 410 530 16 300 700 350 85 410 530 20 350 800 400 85 410 530 24 400 1000 500 85 610 710 46 800 1250 580 85 580 680 60 1700 1400 700 85 800 950 160 2000 1600 700 110 800 950 170 2500 1800 920 110 900 1050 240 3000 2000 1020 110 1200 1350 335 4000

Where: D : Flange diameter mm. d : Barrel diameter mm.

d1: Axis hole diameter mm.

B1 : Distance between flanges mm.

B2 : Overall width mm.

W1: Approximate net weight of drum Kg.

W2: Maximum gross weight of drum Kg.

H 10 Technical Information

Multiply By To Multiply By To obtain Weight – Imperial Length – Imperial Ounces 28.495 grams Mils 0.001 Inches Pounds (AV) 453.59 grams Mils 0.0254 mm Pounds (AV) 0.45359 kilograms Inches 1000 Mils Tons (short) 907.19 kilograms Inches 25.40 Mm Tons (long) 1016.05 kilograms Inches 2.54 Cm

Weight – Metric Feet 30.48 Cm Grams 0.03527 Ounces Feet 0.3048 Meters Grams 0.002205 Pounds Feet (thousands of) 0.3048 Kilometers Kilograms 35.274 Ounces Yards 0.9144 Meters Kilograms 2.2046 Pounds miles 1.3093 Kilometers Kilograms 0.001102 Tons (short) Length-metric Kilograms 0.0009842 Tone (long) Millimeters 39.37 Mils Millimeters 0.03937 inches Miscellaneous – Imperial Centimeters 0.3937 Inches Pounds per 1000 feet 1.48816 Kg/ Km Centimeters 0.032808 Feet Pounds per mile 0.28185 Kg/ Km Meters 39.37 Inches Pounds per square inch 0.0007031 Kg. per square mm. Meters 3.2808 Feet Pounds per square inch 0.07031 Kg. per square cm Meters 1.0936 Yards Pounds per cubic 27.68 Grams per cubic cm Kilometers 3280.83 Feet Feet per second 18.288 Meters per minute Kilometers 0.62137 Miles Feet per second 1.09728 Kilometers per hour Miles per hour 1.60935 Kilometers per hour Area – Imperial Ohms per 1000 feet 3.28083 Ohms per kilometer Square mils 1.2732 Circular mils Ohms per mile 0.62137 Ohms per kilometer Square mils 0.000001 Square inches Decibels per 1000 feet 3.28083 Decibels per kilometer Circular mils 0.7854 Square mils Decibels per mile 0.62137 Decibels per kilometer Circular mils 0.0000007954 Square inches Decibels 0.1153 nepers. Square mils 0.0005037 Square mm. Square inches 1000000 Square mils Miscellaneous – Metric Square inches 1273240 Circular mils Kg / Km 0.67197 Pounds per 100 feet Square inches 645.16 Square mm Kg / Km 3.54795 Pound per mile Square inches 645.16 Square cm. Kg. per square mm 1422.34 Pound per square inch Square feet 0.09290 Square meters Kg. per square cm 14.2234 Pound per square inch Square yards 0.8361 Square meters Grams per cubic cm 0.03613 Pound per cubic inch Meters per minute 0.05468 Feet per second Area – Metric Kilometers per hour 0.91134 Feet per second Square millimeters 1973.52 Circular mils Kilometers per hour 0.62137 Miles per hour Square millimeters 0.00155 Square inches Ohms per kilometer 0.3048 Ohms per 1000 feet. Square centimeters 0.155 Square inches Ohms per kilometer 1.6093 Ohms per mile Square meters 10.7638 Square feet Decibels per kilometer 0.3048 Decibels per 1000 feet Square meters 1.19599 Square yards Decibels per kilometer 1.6093 Decibels per mile Volume – Imperial Temperature Cubic inches 16.38716 Cubic cm. Fahrenheit 5/9(*F)-32 *Celsius Cubic feet 0.028317 Cubic meters. Celsius 9/5 (*C)+32 * Fahrenheit Volume – U. S. Quarts (liquid) 0.9463 Liters Gallons 3.7854 Liters

Volume – Metric Cubic cm 0.06102 Cubic incuse Cubic meters 35.3145 Cubic feet. Liters 1.05668 Quarts.(liquid U.S) Liters 0.26417 Gallons (U.S.)

H 11 H 12 Glossary Glossary Glossary

A Area of conductor The size of conductor cross-section measured in circular mils, square inches, etc. Abrasion Resistance: Armor A braid or wrapping of metal, usually steel, used for mechanical Ability of a material or cable to resist surface wear. protection. A.C. Resistance Armored cable The total resistance offered by a device to alternating current A cable having a metallic covering for protection against circuit due to inductive and capacitive effects, as well as the mechanical injury. direct current resistance. Active current Astm The American society for Testing and materials In an alternating current, a component in phase with the voltage. The working component as distinguished from the Attenuation idle or wattles component. The reduction in a transmitted signal as it passes through wires Aerial cable or equipment in an electrical circuit. A cable suspended in the air on poles or other overhead AWG structure. Abbreviation for American wire gauge. Air core cable A telephone cable in which the interstices in the cable core B are not filled with a moisture bloking material. Air spaced coaxial cable Balance circuit One in which air is the essential dielectric material. A spirally A circuit so arranged that the impressed voltage on each wound synthetic filament or spacer may be used to center conductor of the pair are equal in magnitude but opposite in the conductor. polarity with respect to ground. Alpeth Band width A telephone cable having an aluminum shield and a The frequency range of transmitted electrical signals, expressed polyethylene jacket. in Hertz. Alternating current (A.C.) Bare conductor An electric current that continually reverses its direction giving A conductor having no covering. A conductor with no coating a rebetitive plus and minus wave form at fixed intervals. or cladding on the copper. Alternating voltage: Bedding The voltage developed across a resistance or impedance A layer of material applied to a cable immediately below the through which alternating current is flowing. armoring. Ambient temperature Binder The romal temperature within a given area A spirally served tape or thread used for holding assembled American wire gauge cable components in place awaiting subsequent A standard used in the determination of the physical size manufacturing operations. of a conductor determined by its circular mil area. Usually Bonded flat cable expressed as AWG. Also referred to as brown and sharpe Flat cable consisting of individually insulated conductors lying (B&S) wire gauge. parallel and bonded together typically for application in Ampacity: electronics, telecommunications. Or computers. The maximum current an insulated wire or cable can safely Braid carry without exceeding either he insulation or jacket material A fibrous or metallic group of filaments interwoven in cylindrical limitations (Same as current carrying capacity). form to form a covering over one or more wires. Ampere Braid angle The unit current. One ampere is the current flowing thought The smaller of the two angles formed by the shielding strand on ohm of resistance at one volt potential . and the axis of the cable being shielded. Anneal Breakdown of insulation To subject to high heat wit subsequent cooling. When Failure of an insulated conductor resulting in a flow of current annealing copper, the act of softening the metal by means through the insulation. It may be caused by the application of of heat to render it less brittle excess voltage or by defects or decay. Anode Breakdown voltage The electrode through which a direct current enters the The voltage at which the insulation between two conductors liquid, gas or other discrete part of an electrical circuit; the breaks down. positively charged pole of an electrochemical cell. Bunched Strand Appliance wire and cable Any number of conductor strands twisted together in one Appliance wiring material is a classification of underwriters’ direction with the same lay length. laboratories, inc., covering insulated wire and cable, internal wiring of appliances and equipment. Each construction Buried Cable satisfies the requirements for use in particular applications. A cable installed directly in the ground without use of underground conduit. Also called “ direct burial cable”.

I 2 Glossary

C Colour Code A colour system for circuit identification by use of solid colours, Cable tracers, braids , surface printing, etc. Composite cable A group of individually insulated conductors in twisted or A cable consisting of two or more different types or sizes of parallel configuration, with or without an overall covering. wires. Cable, Star Quad Concentricity A multicore radio or television relay cable in which the In a wire or cable, the measurement of the location of the conductors are arranged in quads and each quad center of the conductor with respect to the geometric center consists of four conductors twisted together, the diagonally of the circular insulation. opposite conductors constituting a pair circuit. Also known Concentric Stranding as spiral four cable. A group of wires twisted so as to contain a center core with one Cabling or more distinct layers of spirally wrapped, wires laid overall. The act of twisting together two or more insulated Conductance The ability of a conductor to carry electric current. It is the components by machine to form a cable. reciprocal of resistance and is measured in Mhos. Capacitance: Conductivity Storage of electrically separated charges between two A term used in describing the capability of a material to carry an plates having different potentials. electrical charge. Usually expressed as a percentage of copper The value depends on the surface area of the plates and conductivity copper being one hundred (100%) percent. the distance and material between them. Conductor Capacitance, Direct: Any material capable of transferring electrical charge easily. The capacitance measured directly with all other Control cable conductors, including shield, short circuited to ground. A multi-conductor cable made for operation in control or signal circuits. Capacitance, Mutual Core The capacitance between two conductors with all other In cables, a term used to denote a component or assembly of conductors, including shield, short circuited to ground. components, over which other materials are applied, such as Capacitance unbalance additional components, shied, sheath, or armor. The inequalities of the capacitances of the wires of a Cross-Sectional Area telephone circuit to other wires or to earth which produce The area of the cut surface of an object cut at right angles to interference. Various forms of unbalance arise according the length of the object. to the circuits concerned in the measurement, hence Crosstalk side-to-side, pair – to- pair unbalance. Signal interference between nearby conductors caused by pickup of stray energy. It is also called induced interference. Capacitance unbalance to ground Cure An inequality of capacitance between the ground To change the physical properties of a material by chemical capacitance the conductors of a pair which results in reaction, by the action of heat and catalysts, alone or in a pickup of external source energy, usually from power combination, with or without pressure. transmission lines. Current Capacitance coupling The rate of flow of electricity in a circuit , measured in Electrical interaction between two conductors caused by amperes. the capacitance between them. Current Carrying Capacity Characteristic impedance The maximum current an insulated conductor or cable can continuously carry without exceeding its temperature rating. It The impedance that , when connected to the output is also called ampacity. terminals of a transmission line of any length, makes the Current, Direct (D.C.) line appear infinitely long. The ratio of voltage to current Electrical current whose electrons flow in one direction only ; it at every point along a transmission line on which there are may be constant or pulsating as long as their movement is in the no stranding waves. same direction. Charge Cycle The quantity of electricity held statically in a capacitor or The complete sequence of alternation or reversal of alternation an insulated conductor. or reversal of the flow of an alternating electric current. (See Circular Mil Hertz) A measurement used in determining the area of wire. The area of a circle one thousandth (.001) of an inch in D diameter. Coating D.C. A material applied to the surface of a conductor to Abbreviation for “Direct Current” prevent environmental deterioration, facilitate soldering or improve electrical performance. Decibel (dB) Coaxial Cable A unit to express differences of power level. Used to express power gain in amplifiers or power loss in passive circuits or A cable consisting of two cylindrical conductors with a cables. common axis, separated by a dielectric.

Cold Test Any test to determine the performance of cable during or after subjection to a specified low temperature for a specified time. I 3 Glossary

Dielectric Constant (K) Filler The ratio of the capacitance of a capacitor (or consoles) (1) A material used in the cable to fill large interstices with dielectric between the electrodes to the capacitance between electrical components; with air is between the electrodes. Also called permittivity (2) A substance, often inert, added to a compound to and specific inductive capacity. improve propertied and / or decrease cost. Dielectric Strength Film A thin plastic sheet. The voltage which an insulation can withstand before Flame Resistance breakdown occurs. Usually expressed as a voltage gradient Ability of the material to extinguish flame once the source (such as volts per mil). of heat is removed Dielectric test Flat cable A test in which a higher than the rated voltage is applied for A cable with two essentially flat surfaces a specified time to determine the adequacy of the insulation Flexible Cable under normal conditions. A cable containing one or more cores, each formed of a Direct capacitance group of wires, the diameters of the wires, the diameters of The capacitance measured directly from conductor to the wires being sufficiently small to afford flexibility. conductor through a single insulation layer. Flexibility Direction of Lay The ease with which a cable may be bent The direction, either clockwise or counterclockwise, of a Foamed Plastics conductor or group of conductors when looking axially Plastic insulations having a cellular structure. down a cable length. Foamskin Drain Wire Polyethylene foam insulation In a cable, an uninsulated wire laid over the component or Frequency component and used as a ground connection. Normally Number of times an alternating current reverses itself in one second. Expressed in Hertz (Hz), which is one cycle per laid in contact with a metallic foil shield. Drawing second. In the manufacturing of wire, pulling the metal through a die G or series of dies for reduction of diameter to a specified size. Drop Wire Gauge A telephone cable, usually consisting of one insulated A term used to denote physical size. telephone pair, which is used to connect a subscribers premises to open wires lines on poles. H

Harness An arrangement of wires and cables, usually with many E breakouts , which have been tied together or pulled into Eccentricity a rubber or plastic sheath, used to interconnect electric circuit. Like concentricity, a measure of the center of a conductor’s Heat Resistance location with respect to the circular cross-section of Ability of a substance to maintain physical chemical the insulation; expressed as a percentage of center and electrical integrity under specified temperature displacement of one circle within the other. conditions. ElA Henry Abbreviation for Electronic Industries Association. Unit of inductance such that the induced voltage in volts Elongation is numerically equal to the rate of change of current in The fractional increase in length of a material stressed in amperes per second. tension. Hertz (Hz) Embossing A term replacing cycles-per seconds as a unit of A means of identification or lettering usingheat and or frequency. pressure to leave raised lettering on the sheath material of High Temperature wire and cable the cable. Those electrical wires and cable having thermal operating o Emergency overloads characteristics of 150 C and higher. Loads which occur when larger than normal currents are Hz Abbreviation for Hertz. carried through a cable or wire oven a short period time. Extrusion I The process of continuously forcing a plastic or elastomer and a conductor core through a die, thereby applying a ICEA continuous coating of insulation or jacket to the core or Insulated Cable Engineers Association (formerly IPCEA). conductor. IEC International Electrotechnical Commission, Similar to the F ISO in structure and scope. IEEE Farad Institute of Electrical and Electronic Engineers. A unit of electrical capacity Fext Far end crosstalk Figure 8 cable An aerial cable configuration in which the conductors and the strand which supports the cable are integrally jacketed a cross-section of the finished cable approximates the figure “eight”. I 4 Glossary

Impedance Longitudinal shield The total opposition that a circuit offers to the flow of A tap shield, flat or corrugated, applied longitudinally alternating current or any other varying current at a along the axis of the cable core being shielded particular frequency. It is a combination of resistance Loop Resistance R and reactance X, measured in ohms. The total resistance of two conductors measured Impulse (Or pulse) round trip from one end. A surge of unidirectional polarity. Loss Factor Induced Current The product of the dissipation and dielectric constant An electric current set up in a circuit by interacting of an insulating material. electrical fields a current caused by electromagnetic induction. M Inductance The property of a circuit element that opposes a Marker Tape change in current flow, thus causing current change A tap laid parallel to the conductors under the sheath to lag behind voltage changes. It is measured in in a cable, imprinted with the manufacture’s name Henrys. and the specification to which the cable is made. Induction Other information such as date of manufacture may The phenomenon of a voltage, magnetic field or also be included. electrostatic charge being produced in an object by MCM lines of force from the source of such fields. One thousand circular Mils. Inductive coupling Megohm Crosstalk resulting from the action of the One million ohms electromagnetic field of one conductor on the other. Mho Insulation The unit of conductivity. The reciprocal of an ohm. A non-conductive material usually surrounding or Mhz separating two conductive materials. Often called Megahertz (one million cycles per second) the dielectric in a radio frequency cable. Microphonics Insulation Resistance Noise in a system caused by mechanical vibration of That property of an insulating material which resists components within the system. electrical current flow through the insulating material Microwave when a potential difference is applied. A short (usually less than 30cm.) Electrical wave. Insulation Thickness Mill The wall thickness of the applied insulation A unit used in measuring diameter of a wire or Interference thickness of insulation over a conductor. One one- Any undesired electrical signal induced into a thousandth of an inch (0.001”). conductor by electrical or electromagnetic means Moisture Resistance (Noise) The ability of a material to resist absorbing moisture ISO from the air or when immersed in water. International Standards Organization Multi-Conductor More than one conductor within a single cable. Mutual inductance The ratio of voltage induced in one conductor to the time rate of current change in the separate J conductor causing this induction. Mylar Jacket DuPont trademark for polyethylene terephthalate A material covering over a wire insulation or an (polyester) film used in the form of a tape. assembly of components. An overall jacket on a complex cable grouping is also often referred to as a sheath.

K N

Kilohertz Next 1.000 Hertz (cycles per second) Near end crosstalk Kilovolt A term denoting 1000 volts. O Kilowatt A term denoting 1000 watts. Ohm Unit of resistance such that a constant current of one L ampere produces a force of one volt. Overall Diameter Lay Direction Finished diameter over wire or cable The direction in which the strands of a conductor run Over Current over the top of the conductor as they recede from and The Current which causes and excessive temperature observer looking along the axis of the conductor. rise in a conductor. Leakage Current Overload Capacity The undesirable flow of current through or over the The maximum level of current, voltage, or power which surface of an insulation a device can withstand before it is damaged.

I 5 Glossary

Oxygen index RFI Percentage of Oxygen necessary to support combustion Radio Frequency Interference. of specified material. RG/U P Radio Government, Universal. RG is the military designation Pair for coaxial cable and U stands for “ general Utility”. Two insulated wires of a single circuit associated Round Conductor together. A conductor whose cross-section is substantially circular Peak Voltage The maximum instantaneous voltage. Percent Conductivity S Conductivity of a material expressed as a percentage of Sheath that of copper The material, usually an extruded plastic or elastomer, Polyester applied outermost to a wire or cable. Very often refereed Polyethylene terephthalate which is used extensively in to as a jacket. the production of a high strength moisture resistant film Shield used as cable core wrapping material. A metallic layer around an insulated conductor or group Polyethylene of conductors to prevent electrostatic or electromagnetic A family of insulating materials derived from polymerization interference between the enclosed wires and external of ethylene gas. They are basically pure hydrocarbon fields. This shield can be braided or served wires, foil resins, with excellent dielectric properties. Polypropylene wrap, foil backed tape, a metallic tube , or conductors, the shielding effectiveness is in proportion to the amount A thermoplastic polymer of propylene. of coverage, usually expressed in percentage. Polyvinlychloride (PVC). Shield Coverage A thermoplastic material composed of polymers of The physical area of a cable that is actually covered by vinylchloride which may be rigid or eleastomeric, the shielding material and is expressed in percentage. depending on specific formulation. Signal Power Factor Current used to convey information, either digital, The ratio of resistance to impedance. The ratio of the analogue, audio or video. actual power of an alternating current to apparent Single cable power. Mathematically, the cosine of the angle between A cable designed to carry current of usually less than one the voltage applied and the current resulting. ampere per conductor. Propagation time Skin Effect The required for an electrical wave to travel between two The tendency of alternating current, as its frequency points on a transmission line. increases, to travel only on the surface of a conductor. Pulse Solid Conductor A current or voltage which changes abruptly from one A conductor consisting of a single wire. value to another and back to the original value in a finite Spark Test length of time. A test designed to locate imperfections (usually pin- Pulse Cable holes) in a wire insulation by application of an electrical A type of coaxial cable constructed to transmit repeated potential across the material for a short period of time high voltage pulses without degradation. while the wire is drawn through an electrode field with one end of the wire grounded. Q Specific Gravity Quad The ratio of the weight of any volume of substance to A four- wire unit of insulated conductors. See star quad a weight of an equal volume of some substance taken as a standard, usually water for liquids and hydrogen for R gases. Square Mil Rated Temperature The area of a square on mil by one mil. The maximum temperature at which an electric Stranded conductor component can operate for extended periods without A conductor composed of individual groups of wires loss of its operating properties twisted together to form an entire unit. Rated Voltage Strand Lay length The maximum voltage at which an electric component A distance of advance of on strand of a spirally stranded can operate for extended periods without degradation conductor, in one turn, measured axially. of performance or safety hazard. Reactance The opposition offered to the flow of alternating current by the inductance or capacitance of a component or circuit Resistance In D.C. circuits , the opposition a material offers to current, measured in ohms. In A.C. Circuits, resistance is the real component of impedance , and may be higher than the value measured at D.C.

I 6 Glossary

T W

Temperature Rating Water Absorption The maximum temperature at which insulating material Ratio of the weight of water absorbed by a material may be used in continuous operation without loss of its basic properties. to the weight of the dry material. Tensile strength Watt A term denoting the greatest longitudinal tensile stress a A unit of electrical power. One watt is equivalent substance can bear without mechanical failure. to the power generated by one ampere of current Thermal Rating under a pressure of one volt in a D.C. circuit. The maximum and / or minimum temperature at which a Wavelength material will perform its functions without undue degration. Thermal Shock The distance, measured in the direction of A test to determine the ability of a material to withstand propagation, of a repetitive electrical pulse or heat and cold by subjecting it to rapid and wide change waveform between tow successive points. in temperature. Tinned Copper Tin coating over copper to aid in soldering and inhibit corrosion. Tinned wire Copper wire that has been coated with a layer of tin or solder to simplify soldering. Triple (Traid) A cable consisting of there insulated single conductors twisted together. Tubing A tube of extruded non-supported plastic or metallic material. Twin Cable A cable composed of two separated insulated stranded conductors laid parallel under a common covering. Twin Coaxial cable A single cable consisting of two separate coaxial cables laid adjacent and parallel or twisted together. Twisted Pair A twisted pair is composed of two small separately insulated wires twisted together. Twisted Triad Any three individually insulated conductors which are twisted together.

V

Velocity of Propagation The speed of an electric signal down a length of cable compared to speed in free space expressed as a percentage. It is the reciprocal of the square root of the dielectric constant of the cable insulation. Volt (potential difference) A unit of electrical pressure. One volt is the amount of pressure that will cause one ampere of current in one ohm of resistance. Voltage The term most often used in place of electromotive force, potential, potential difference, or voltage drop, to designate electric pressure that exists between two points and is capable of producing a flow of current when a circuit is connected between the two points. Voltage Drop. The amount of voltage loss between two power in a circuit. Voltage Rating The highest voltage that may be continuously applied to a wire or cord in conformance with standards or specifications. Volume Receptivity The electrical resistance between opposite face of a 1 cm cube of insulating material, commonly expressed in ohms/ centimeter. I 7 System’s Certificates

J 1 Product’s Certificates

J 2 Product’s Certificates

J 3 Product’s Certificates

J 4 Elsewedy Cables Catalogues

Power Cables Catalogue - Overhead conductor - Service drop cables - Low voltage cables - Medium voltage cables - High voltage cable - Extra high voltage cables

Special Cables Catalogue - Control cables - Instrumentation cables - Flame retardant cables - Fire resistance cables - Telephone cables - LAN cables - Co-axial cables - Audio cables - Profibus cables - Irrigation cables - Pilot cables - Flat cables - Automotive wires - Appliance cables & cords

Winding Wires Catalogue - Enameled copper cables - Paper insulated flat wires - Plain copper wires - Tinned copper wires - Bare copper wires - Welding wires

Low Smoke Halogen Free (LSHF) Catalogue - Single core cable - Multi core cable

Telecom Cables Catalogue - OPGW - Fiber optics cables - Comcore Elsewedy Cables Contacts

Elsewedy Cables Head Office

Local: 4-Elsewedy Electric Ghana (Fiber Glass Poles) 16 Baghdad st. – EL Korba – Heliopolis, . Egypt 9, Light Industrial Area No. A/36/2B Tema - Ghana Tel.: +(202) 26904311/2-3 Fax: +(202) 24170173 Tel.: +23311101 -311102 Fax: +23311103 Email: [email protected] Email: [email protected] Export: 5-Elsewedy Electric Syria (Transformers) Tel.: +963 11 5850 215 Fax: +963 11 5850 216 16 Baghdad st. – EL Korba – Heliopolis, Cairo . Egypt Email: [email protected] Tel.: +(202) 26904311/2-3 Fax: +(202) 24170173 6-Elsewedy Transformers (Transformers) Email: [email protected] 14 Baghdad St. El Korba, Heliopolis, Cairo - Egypt Tel.: +(202) 24144380- 24144381 Fax: +(202) 22905844 - 24144383 Wires & Cables Sector Email: [email protected] [email protected] 1-Arab Cables (Power Cables) 7-ltalsmia (Explosion Proof Equipment) 14 Baghdad St. El Korba, Heliopolis, Cairo Egypt Tel.: 015411141 Fax: 015 411142 Tel.: +(202) 22909430 - 24187371 - 24187372, 24187361, 24187362 Email: [email protected] Fax: +(202) 22917078 Email: [email protected] 8-ISKRAEMECO (Meters) Iskraemeco Savaska loka 4 SI-4000 Krani, Slovenia 2-Egytech Cables (Power Cables) Phone: +38642064000 16 Baghdad St. El Korba, Heliopolis, Cairo - Egypt Email: [email protected] Tel.: + (202) 24148366, 24148370 Fax: +(202) 24148373 Email: [email protected] Turn Key Projects Sector 1-Power System Projects (PSP) 3-United Industries (Enameled Wires - Special Cables - Fiber Glass 31 Ramy Tower, El Shatr EL Sades, Zahraa El Maadi, Cairo, Egypt. Poles) Tel.: +(202) 25215810 / 20 / 30 Fax: +(202) 25165122 Add. 68 El Tayran St., Nasr City, Cairo Email: [email protected] Tel.: +(202) 22 60 3196 – 22 61 8908 - 24 01 3606 Fax: +(202) 22 62 0473 2-Elsewedy Electric Transmission & Distribution Email: [email protected], uic-marketing@uic-elsewedy. Add. 68 El Tayran St., Nasr City, Cairo com Tel.: 22 60 3196 – 22 61 8908 - 24 01 3606 Fax.: 22 62 0473 Email: [email protected] 4-United Metal (Copper Rods) 14 Baghdad St.EI Korba, Heliopolis, Cairo - Egypt Tel.: +(202) 24148369 - 22916507 Fax: +(202) 24196116 International Operations Sector Email: [email protected] 1-Jordan & Iraq 5-Sedplast (PVC Compounds) Elsewedy Cables - Jordan & Iraq 13 El Obour Bldg’s. Salah Salem St. Nasr City, Cairo - Egypt Zahrat El Radwan Building Extension of Garden Street Tel.: +(202) 22623411, 22605405 Fax: +(202) 22623442 Opposite of Medass shop, Amman, Jordan Email: [email protected] Tel.: +962 6 5853802 Fax: +962 6 5853804 Email: [email protected] 6-Egyplast Elsewedy for Plastic Industry EGYPLAST Obour Buildings #13, Salah Salem Street, Nasr City, Cairo, Egypt 2-Malawi Tel.: +(202) 22632411 – 22632442 Fax: +(202) 24033285 Elsewedy Cables - Malawi E263 Post Dot Net Blantyre-Malawi 7-United Wires Tel.: +265 1 878 878 Fax: +265 1 878 788 Cell: +265 9 788 87 10th of Ramadan City, Zone A3, El-Sharkia, Egypt Email: [email protected] Tel.: +2015411944 Fax: +2015411941 Email: [email protected] 3-Ethiopia Elsewedy Cables - Ethiopia 8-Giad Elsewedy (Power Cables) Ries Engineering Share Company PO Box 1116, Al Hourea St. Al Khartoum, Sudan Debrezeit Road Addis Ababa, Ethiopia Tel.: +249 183 2764117/8 Fax: +249 183 2764116 Tel.: +251 11 440 17 39 Fax: +251 11 442 06 67 Email: [email protected] Email: [email protected]

9-Elsewedy Cables ,Syria (Power Cables) 4-Kuwait 139 Kafr Sousa Bldg s (Main Rood), Damascus, Syria- Elsewedy Cables - Kuwait RO.BOX: 36633 Al Kazemi International for General Trading & Contracting Tel.: +963-11-25850207-25850212 Fax: +963-11-25850206 Al Salmeya, Laila Tower, E-mail: [email protected] 4th floor PO Box 403 Safat, 13005 Kuwait Mob: +9657861325 Fax: +9656723196 10-Elsewedy Cables Saudi Arabia (Wires & Cables) Email: [email protected] Nassar Center, King Fahd Road Al Aziziah, Jeddah Postal code: 860223337 Jeddah 5-UAE Tel.: +96626687380/88/99 Fax: +96626687480 Elsewedy Cables - Emirates Email: [email protected] [email protected] Business Avenue Building – Sheikh Rashid Road PO Box 90305 Dubai, UAE 3rd Floor – Office no. 312 11-Elsewedy Cables Algeria (Power Cables) Tel.: +97142955905 Fax: +97142955135 153 rue Ali Khodja, El Biar, Alger, Algérie. Email: [email protected] Tel.:+213 21 92 40 05/07 Fax: +213 21 92 39 97 Email: [email protected] 6-Yemen Elsewedy Cables - 12-Elsewedy Cables Qatar (Power Cables) Hadda Towers - Hadda PO BOX: 888-Tower No.6 Elsewedy Cables - Nuiaja area, villa # 36 N.B.S. D-ring road, P.O. Box 7th Floor- Office No.13-Sanna-Yemen 3988, Doha Qatar. Tel.: +967734023861 Fax : +9671430853 Tel.: +974 4652645 \ 4568612 Fax: +974 4653892 \ +974 5899047 Email: [email protected] Email: [email protected] 7-Guinea 13-Elsewedy Cables Egypt (Power Cables) Elsewedy Electric - Guinea 16 Baghdad St. El Korba, Heliopolis, Cairo - Egypt Equatorial Pork Of Africa, Caracoles, Tel. : +(202) 24148366, 24148370 Beside Military Camp, Malabo, Equatorial Guinea Fax: +(202) 24148373 Tel.: +(240) 096 569 Fax: +(240) 096 569 Email: [email protected] Email: [email protected] 8-Nigeria Electrical Products Sector Elsewedy Cables - Nigeria 1-SEDCO (Cables Accessories) 10 Bauchi Close Agbara Estate, Ogun State Lagos-Nigeria 13 El Obour Bldg,s, Salah Salem St. Nasr City, Cairo - Egypt Tel.: +234 7033475772 Tel.: +(202) 24023683 - 22626763 Fax: +(202) 22639155 9-Libya Email: [email protected] Elsewedy Cables - Libya 2-Elastimold (Cables Accessories) Gergarash -Hay El Andalous, Tripoli-Libya 13 El Obour BIdg’s, Salah Salem St. Nasr City, Cairo - Egypt Tel.: +218 91 325 96 25 Tel.: +(202) 24023683 - 22626763 Fax: +(202) 22639155 Email: [email protected] Email: [email protected] 8-India 3-Sudanese Egypt Electrical Industries SUDATRAF (Transformers) Elsewedy Cables - India El Kuwaiti Buildings -4th tower - 7th stage Khartoum Office No. 412, ‘A’ Wing, Sagartech Plaza, Sudan P.O.B 1380 Khartoum Andheri-Kurla Road, Andheri (East) Mumbai-400072, India Tel.: +249 183 2764118 Tel.: +91-22-65283183 / 66790130 Fax: +91-22-66790131