Whole House Dehumidifier
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Common Duct Insulation Materials Supplement F
Supplement F Common Duct Insulation Materials The Washington State Energy Code (WSEC) Hotline has received questions about different types and thicknesses of duct insulation. There appears to be some confusion about Table 5-11 of the WSEC which lists the minimum densities, out-of-packages thickness and R-values for different types of duct insulation. Table F-1 shows what the R-values are for varying thicknesses and types of duct insulation in a better layout than Table 5-11. This table also lists the ASTM and UL. Table F-1 R-Values for Common Duct Insulation Materials Installed R-Value1 Typical Material meeting or exceeding the given R-value2 (h.°F sq.ft.)/Btu 1/2-inch Mineral fiber duct liner per ASTM C 1071, Type I 1.9 1-inch Mineral fiber duct wrap per ASTM C 1290 1-inch Mineral fiber duct liner per ASTM C 1071, Types I & II 1-inch Mineral fiber board per ASTM C 612, Types I & IB 3.5 1-inch Mineral fiber duct board per UL 181 1-1/2-inch Mineral fiber duct wrap per ASTM C 1290 1-inch Insulated flex duct per UL 181 1-1/2-inch Mineral fiber duct liner per ASTM C 1071 1-1/2-inch Mineral fiber duct board per UL 181 1-1/2-inch Mineral fiber board per ASTM C 612, Types IA & IB 6.0 2-inch, 2 lb/cu.ft. Mineral fiber duct wrap per ASTM C 1290 2-1/2-inch, .6 to 1 lb/cu.ft. Mineral fiber duct wrap per ASTM C 1290 2-1/2-inch Insulated flex duct per UL 181 2-inch Mineral fiber duct liner per ASTM C 1071, Types I & II 2-inch Mineral fiber Duct board per UL 181 8.0 2-inch Mineral fiber board per ASTM C 612, Types 612, Types I! & IB 3-inch 3/4 lb/cu.ft. -
Whole-House Duct Mount Hepa Air Cleaner
MODEL DA-HEPADM400-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER Description The DIRECT AIR Whole House Duct Mount HEPA Cabinet Construction Features Air Cleaner has been designed to remove atmospheric and household dust, coal dust, One piece wrap, steel cabinet has powder-coat insecticide dust, mites, pollen, mold spores, fungi, paint finish to provide rigid installation and durabil- bacteria, viruses, pet dander, cooking smoke and ity. grease, tobacco smoke particles, and more down Pre-punched openings at back of unit and mount- to 0.3 micron (1/84,000 of an inch) with 99.97% ing template are provided for easier duct mount efficiency on the first pass of air. installation; no external ducting required. It’s ideal for homes that have tight space condi- Pre-punched openings at top and bottom of unit tions in their furnace/air conditioning rooms. This facilitate collar mount installation. unit is compact and can be installed directly on the return air vent. It can also be mounted directly to Media Replacement Filters the furnace and collar mounted to the return air duct to save space. PART REPLACE Ideal for homes with allergy, asthma or respiratory NUMBER DESCRIPTION EVERY sufferers, smokers, pets, cooking odors and musti- ness. DMH4-0400 HEPA Media Filter 2-3 years Helps protect and prolong the operating efficiency of the heating and cooling equipment. DMH4-0855 Prefilter, MERV 11 3-6 months Standard Features DMH4-0810 Carbon Prefilter 3-6 months Highly Efficient MERV 11 Prefilter removes lint and hair before they enter HEPA filter. Activated Carbon Prefilter removes odors to ex- tend the life of the HEPA filter. -
Guideline on Through Penetration Firestopping
GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E. -
Duct Liner Insulation
Duct Liner Insulation Product Performance for Lining HVAC Ducts ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER In April 2012, K-FLEX USA was awarded of closed cell flexible elastomeric foam with ISO 9001:2008 certification by FM insulation products for mechanical Approvals. The independent certification piping, air handling units and vessels. demonstrates the company’s commitment to quality. Designed for ease of installation and reliable performance, K-FLEX® products K-FLEX products have proven performance provide excellent thermal and acoustical in the Plumbing, HVAC/R, Commercial/ performance, including inherent Industrial, Marine, Oil & Gas, Acoustic resistance to moisture intrusion. and OEM Markets. Youngsville, NC Headquarters K-FLEX USA prides itself on being As a member of the IK Insulation Group, responsive to the market, providing K-Flex USA delivers state-of-the-art levels dependable service to customers of technical knowledge and customer throughout North America, bringing an support to the global mechanical innovative approach to product offerings, insulation market. and having products that are 3rd party tested and certified. ISO 9001 CERTIFIED COMPANY HISTORY 2001 Nomaco Insulation and 1989 L’Isolante K-FLEX joined to 2004 1965 L’Isolante K-FLEX was formed. form Nomaco K-FLEX (NKF). NKF acquired RBX’s mechanical insulation Rubatex was formed. business. 1975 1999 2002 2008 Halstead was formed and INSUL-TUBE® Rubatex acquired NKF entered into a Sales & L’Isolante K-FLEX and became a well-known product brand. Halstead -
VOC Duct and Rough Service Sensor Air Quality Sensors Rev
D10 VOC Duct and Rough Service Sensor Air Quality Sensors Rev. 12/19/16 Features & Options l Corresponds to ASHRAE’s CO2-Based DCV Algorithm l Duct Aspiration Tube or Rough Service Ventilated BAPI-Box l 0 to 5 VDC or 0 to 10 VDC Output Humans respirate Volatile Organic Compounds (VOCs) as well as CO2. The BAPI sensor measures these VOCs and indicates when a space is occupied just as well as a CO2 sensor. The advantage of the VOC sensor is that it measures air contaminants from other sources besides respiration, such as building materials, cleaners, perfumes and furniture and carpet VOC Duct Sensor off-gassing. Using this sensor for Demand Controlled Ventilation then is a way of achieving true indoor air quality, rather than just CO2 dilution. A further benefit is that it requires no additional work on your part. That’s because the sensor converts the VOC reading to a CO2 equivalent level. This lets you use ASHRAE’s CO2- based VRP schedule to ventilate. (More information on the CO2 equivalent output is available on our website or in the Application Notes at the end of this section.) The Duct Sensor samples duct air using an aspiration tube, while the Rough Service unit features a ventilated BAPI-Box and is ideal for areas such as outdoor air plenums, equipment rooms, green houses and warehouses. The VOC level is indicated as “Good, Fair or Poor” by three discrete green, yellow and red LED’s on the front of the unit. If the output reaches 2,000 PPM, the red LED VOC Rough Service Sensor will begin to flash because it has hit its maximum output. -
To the NADCA Standard ACR
Joe, the title of the document should read “Air Systems Cleaning Specialists” and also at the bottom of each page it reads Air Cleaning System Specialists. Air Systems Cleaning Specialist To the NADCA Standard ACR Copyright © 2013 NADCA, All Rights Reserved ii | NADCA AIR SYSTEMS CLEANING SPECIALIST TABLE OF CONTENTS NADCA Air Systems Cleaning Specialist MODULE 1 Overview of Heating Ventilating and Air-Conditioning (HVAC) Systems Cleaning ..................1 History of Heating Ventilating and Air-Conditioning (HVAC) Systems Cleaning ................1 Factors Affecting the HVAC (Duct) Cleaning Industries Growth ............................................2 What is HVAC Contamination Composed Of? ..........................................................................3 The National Air Duct Cleaners Association (NADCA) ...........................................................4 MODULE 2 HVAC Systems Overview ....................................................................................................................7 Principles of Heating Ventilation and Air Conditioning Systems ............................................7 Types of HVAC Systems...............................................................................................................27 Basic Components of HVAC Systems ........................................................................................31 MODULE 3 Protecting Health & Safety of Occupants and Building .................................................................45 Preliminary Recommendations -
The Gold Standard in Fan Heaters
WALL FAN HEATER ARWF SERIES THE GOLD STANDARD IN FAN HEATERS The PULSAIR™ is extremely popular for many reasons. First, it can be recessed or surface mounted with a surface adapter (optional). In addition, it can be mounted vertically or horizontally, directing the air flow upward or downward and to the right or to the left, respectively. Last, the slim-line PULSAIR™ can be recessed into W W W W Y Y Y A A A A T T a wall thickness of 2 in. to 3 in. While it’s a winning heating solu- T R R R R N N N R R R R A A A LIFETIME A A A A R R R N N N N R R R on element T T T T A A A tion for the hallway and bathroom, it can also be installed in other Y Y Y Y W W W W W W parts of the house, such as the office or in commercial buildings. W Y Y Y Y A A A A T T T T R R R R N N N R N Its nichrome element provides instant heat. Available from 500 W R A R A R A A A A R A R A R R N N N N 2YEAR R 3YEAR R 5YEAR R 5YEAR R T A T A T A T to 2000 W, and from 120 V to 277 V, the PULSAIR™ is recognized Y Y Y Y A W W W W W W W W and recommended by those in the know. -
Single Pole Humidity Sensor and Fan Controller Cat
Single Pole Humidity Sensor and Fan Controller Cat. Nos. IPHS5 - INDOOR USE ONLY 120VAC, 60Hz - Single Pole Only Incandescent: 600W - MLV/Fluorescent: 400VA - LED/CFL: 150W - Fan: 1/6Hp WARNINGS CAUTIONS • TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER • Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! liquids. • TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to • No user serviceable components. DO NOT attempt to service or repair. control a receptacle, or a load in excess of the specified rating. • Use this device WITH COPPER CLAD WIRE ONLY. • To be installed and/or used in accordance with electrical codes and regulations. • If you are not sure about any part of these instructions, consult an electrician. DI-000-IPHS5-02B INSTALLATION ENGLISH Features Location You Will Need: The humidity sensor and fan controller senses the humidity of your bathroom • Slotted/Phillips screwdriver • For bathroom applications the device should be placed and turns your bath fan or fan/light on when the humidity gets too high, • Pencil reducing condensation in your bathroom and increasing ventilation when used at a level to detect steam. Placing the detector directly in other household spaces. above a heater or near drafts is not recommended. • Electrical tape • Compatible with Incandescent, LED, CFL and Fluorescent loads when • NOTE: DO NOT use to control a fan/light combination • Cutters used with combination fan and light fixtures. where the fan/light is the only means of illumination. -
Technical Standards for the Air Conditioning and Heat Pump Professional
Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS THE SYMBOL OF EXCELLENCE FOR HOME PERFORMANCE CONTRACTORS VERSION 1.1, FEBRUARY 2003 BUILDING PERFORMANCE INSTITUTE, INC. TECHNICAL STANDARDS FOR THE AIR CONDITIONING & HEAT PUMP PROFESSIONAL TABLE OF CONTENTS: PAGE 1. HEALTH AND SAFETY………………..(personal, occupant, electrical, refrigerant) 3 2. INSTALLATION………………………..(design, airflow, duct systems, refrigerant, controls) 5 3. COMMISSIONING……………………..(airflow, duct systems) 12 4. SERVICE AND REPAIR……………….(duct systems, refrigerant, airflow) 13 5. DIAGNOSTIC TESTS………………….(electrical, airflow, duct systems, refrigerant) 17 VERSION 1.1, FEBRUARY 2003, CKM ACKNOWLEDGEMENTS The following standards were developed for the Building Performance Institute, Inc. (BPI) with assistance from an expert panel, the BPI Technical Advisory Council, and the BPI Technical Committee. These groups include industry stake-holders including: contractors, licensing and code officials, weatherization agencies, program administrators, equipment manufacturers, researchers, and trainers. This document, released in 2003, is the result of their efforts. For additional information, contact BPI. BPI AIR CONDITIONING AND HEAT PUMP EXPERT PANEL PARTICIPANTS: Robert DeKieffer, Boulder Design Alliance Patrick Murphy, North American Technician Excellence Terry Norris, Advanced Energy Corporation John Proctor, Proctor Engineering Group Additional thanks goes to the New York State Energy Research and Development Authority (NYSERDA) and the U.S. Environmental Protection Agency (EPA) for providing necessary funding to support this project. USE AND DISTRIBUTION OF BPI STANDARDS This document was prepared by BPI to provide a guiding set of technical performance standards for use by BPI certified technicians. The certification process ensures technicians utilizing these standards have demonstrated competency at both the skill and knowledge required to apply the techniques and applications referenced herein. -
Hazards / Problems Associated with Fiberglass Duct Liner and HVAC Insulation
Hazards / Problems Associated with Fiberglass Duct Liner and HVAC Insulation Guidance for Insulating New HVAC/Ductwork DC Indoor Air Quality Work Group Background Fiberglass (fibrous glass or glass wool) internal duct liner has been used as acoustical and thermal insulation in many Heating, Ventilation and Air Conditioning (HVAC) systems. Indoor Air Quality (IAQ) complaints may arise when the fiberglass internal duct liner deteriorates over time. Deteriorating fiberglass duct liner, which is typically black in color, can migrate through supply diffusers. The liner can deposit in occupied spaces and onto flat surfaces, where it can cause complaints and adverse health effects. Due to ongoing concerns about exposure to deteriorating fiberglass duct liner, the Indoor Air Quality Work Group of the UC Industrial Hygienists/Safety Committee has decided to address the issue and develop this guidance for the UC campuses. Adverse Health Effects 1. Fiberglass carcinogenicity has been studied and classified by the following organizations: • International Agency for Research on Cancer (IARC) has classified it as a possible human carcinogen • National Toxicology Program (NTP) has classified it as an animal carcinogen • American Conference of Governmental Industrial Hygienists (ACGIH) has classified it as an animal carcinogen (A3) • Environmental Protection Agency (EPA) has classified it as an animal carcinogen. Fiberglass, at a minimum, is an acute physical irritant to the skin, eyes, and upper respiratory tract. The following are occupational exposure limits for fibrous glass or glass wool fibers, developed by US and international agencies: AGENCY / ORGANIZATION EXPOSURE UNIT Cal/OSHA PEL, 2001 (as an 8 hr TWA) 1.0 f/cc ACGIH, 2008 TL V 1.0 f/cc A3 Safety & Health Committee, Bldg. -
Delta Fan Heater
PAGE 1/2 DELTA FAN HEATER DELTA is a robust, reliable fan heater that is designed for use in TECHNICAL DATA areas that require a little more of materials and performance, for Voltage range: instance construction sites and ships. • 1x110V to 3x690V + PE DELTA is also used for more permanent installations such as in- Frequenzy, can be used at: dustrial buildings and warehouses, workshops, factories or ga- • 50 Hz and 60 Hz rages, as it can go from transportable to permanent fixture with Degree of protection for electrical components: a simple wall-bracket. • TP1: 3-9kW = IP44 • TP2: 15-21kW = IP34 It comes with an integrated 0-40°C room thermostat that en- Temperature control: sures optimal operation and minimizes energy consumption, as • TP1: Combi termostat with adjustable room thermostat 0-40°C well as a thermal cut-out to protect against overheating. The + thermal cut-out fan heater works without standby and does not use unneces- • TP2: Adjustable room thermostat 0-40°C + thermal cut-out sary power. Level regulation: • Manually operated 5-level change-over switch that regulates DELTA is built with internal casing in the heating chamber, which air speed and heating effect. Moreover, all types can be sup- ensures that the entire flow of air passes over the heating ele- plied with a 24-hour timer. A DELTA fan heater with timer ments. This eliminates problems with varying airflow and cold function switches on when the set time has elapsed. spots. Off The DELTA fan heater comes in two sizes: • TP1 = 3-9 kW - small cabinet Fan on • TP2 = 15-21 kW - large cabinet Half fan and half heat effect TP1: 372 mm TP1: 300 mm TP2: 462 mm TP2: 360 mm Full fan and half heat effect Full fan and full heat effect TP1: 435 mm TP2: 540 mm TP1: 322 mm ELECTRICAL INSTALLATION TP2: 392 mm Permanent installation must always be performed by an authori- zed electrician in accordance with relevant laws and regulations. -
Airflow Measuring System Using Piezometer Ring – IM-105
IM-105 Piezometer Ring June 2021 Installation, Operation & Maintenance Manual REVIEW AMCA BULLETIN 410 PRIOR TO INSTALLATION This manual has been prepared to guide the users of an airflow measuring system using a piezometer ring in the proper installation, operation and maintenance procedures to ensure maximum equipment life with trouble-free operation. For safe installation, startup and operational life of this equipment, it is important that all involved with the equipment be well versed in proper fan safety practices and read this manual. It is the user’s responsibility to make sure that all requirements of good safety practices and any applicable safety codes are strictly adhered to. Because of the wide variety of equipment covered in this manual, the instructions given here are general in nature. Additional product and engineering information is available at www.tcf.com. SAFETY NOTICE Refer to the safety section(s) in this manual prior to installing or servicing the fan. The most current version of this installation and maintenance manual can be found on our website at www.tcf.com/resources/im-manuals. Table of Contents Safety & Hazard Warnings ...........................................................................................................................................................................2 Shipping & Receiving ....................................................................................................................................................................................2 Handling ......................................................................................................................................................................................................