Whole House Dehumidifier

Whole House Dehumidifier

WHOLE HOUSE DEHUMIDIFIER Installation, Operating, and Maintenance Manual Installation, Operation, and Maintenance Instructions Contents Page 1. Safety .......................................................................... 2 a.Labeling ................................................................... 2 b.Instructions .............................................................. 2 2. Storage ....................................................................... 3 3. Specifications ............................................................. 3 4. Installing the Equipment ............................................. 3 a.Unit Location ........................................................... 3 b.Mounting .................................................................. 3 c.Condensate Drain ................................................... 4 d.Ducts........................................................................ 4 5. Electrical ..................................................................... 4 a.Power Wiring ........................................................... 5 b.(Alternate) Remote Dehumidistat ............................ 5 c.Controls Connections .............................................. 6 d.Damper Connection ................................................ 7 6. Operation .................................................................... 8 a.General .................................................................... 8 b.Process .................................................................... 9 c.Sequence ................................................................ 9 i.Unit controls ........................................................... 9 ii. Wall control ........................................................ 10 iii. Frost control ...................................................... 10 d.Initial Set Up .......................................................... 10 7. Maintenance ............................................................. 11 a.Filter ....................................................................... 11 8. Troubleshooting ........................................................ 11 9. Wiring Diagram......................................................... 12 10. Physical Dimensions .............................................. 12 SAFETY LABELING SAFETY INSTRUCTIONS DANGER!, WARNING! and CAUTION! WARNING! This dehumidifier must be installed by a qualified heating, These words are used to identify levels of hazard ventilation, and air conditioning professional in seriousness as follows: compliance with all codes, local and national. Failure to comply with this WARNING! could result in severe DANGER! Signifies an immediate hazard which will personal injury or death. result in severe personal injury or death. WARNING! WARNING! signifies hazards or unsafe practices which Electrical shock hazard. Disconnect electrical power could result in severe personal injury or death before starting installation. WARNING! CAUTION! Signifies hazards or unsafe practices which Equipment must be grounded electrically in compliance could result in minor personal injury or product and/or with National Electric Code and local codes. property damage. WARNING! Handle unit with care using adequate manpower or equipment to lift and avoid injury to personnel and/or equipment. CAUTION! Failure to install this dehumidifier in compliance with the instructions contained herein, could result in unsatisfactory operation and/or damage to the product. CAUTION! Unit must be installed in compliance with all codes. CAUTION! For proper operation, external static pressures across the unit must not exceed .6 in. w.c. 2 SPECIFICATIONS Capacity Pints per day @ 80°F DBT/60% RH 130 Unit Power Supply Volts/Phase/Hz 115/1/60 Minimum Circuit Ampacity 13.1 Maximum Fuse 15 amp Dimensions Length (overall) 30.00 in. (includes duct collars) Length (cabinet only) 24.00 in. Width 25.25 in. Height 20.50 in. Weight Pounds net 150 Compressor Qty/Type 1/Rotary Watts/RLA/LRA 1070/9.5/61 Refrigerant R22 Fan Motor Qty/HP/FLA 1/0.1/1.15 Air Flow CFM @ .6 in. w.c. e.s.p. 400 Filter Type/size(in.) Washable nylon/17x23.5 Cabinet Insulation Type/thickness EPDM/1 in. R Value 4.2 Duct Connection Inlet/Outlet 8 in. diameter duct Drain Pan Material Stainless steel STORAGE Place the unit in a location that will allow a minimum of 22" clearance for filter removal and Temporary storage must be indoors, upright in the service access. This clearance is required on only original carton, and completely shielded from one side of the unit since the filter is removable precipitation. from either side. Allow adequate clearance to walls for normal unit service. INSTALLING THE EQUIPMENT CAUTION! Do not install the unit outdoors or in a UNIT LOCATION location where it will be subjected to Unit location is very important as it will determine precipitation of any kind. the overall length of the connection ducts. Locate the unit as close as possible to the indoor portion MOUNTING of the resident’s air conditioning unit or air The unit may be mounted on a flat surface or handling unit, in the attic, basement, garage, or suspended. If mounted on a flat surface use the equipment room. The dehumidifier may be placed four rubber mounting feet provided. To minimize above, below or level with the air handing unit; unwanted vibration select a level mounting however, removal of condensate must be surface. Adjust the four mounting feet to considered when determining the location. compensate for any irregularities in the surface. If the unit is mounted above a ceiling or in an Ensure that the unit is sitting on all four feet. To attic, a secondary drain pan under the entire unit suspend the unit a separate hanger kit (WHD-14) is recommended. This pan should have a visible is required. This kit consists of four brackets and overflow drain that will alert the end user that a four rubber isolators. Threaded rod or other problem exists with dehumidifier’s primary means of suspension must be provided by the drainage system. installing contractor and must be selected based on the unit weight, in compliance with local codes. 3 Suspended unit utilizing be in compliance with local codes and be optional hanging kit complete, tight, and leak free. Ducts should be as short as possible, not to exceed 100 ft. equivalent length and supported in compliance with the manufacturer’s recommendation. CAUTION! All duct connections must be sealed. Any leakage in the duct work will adversely affect the operation of the dehumidifier and may lead to unsatisfactory performance. DAMPERS Optional dampers may be installed in the outlet duct, inlet duct, or in an outside air duct. These dampers must be full flow motorized type. Do not use any type of pressure operated damper as unacceptable pressure drop will affect unit operation. All dampers must be installed in compliance with the manufacturer’s recommendations and be insulated, and sealed per the section on ducts, above. CONDENSATE DRAIN The condensate drain must be trapped external to ELECTRICAL the unit. The trap dimensions must be equivalent to the dimension of the trap on the associated air POWER WIRING conditioner air handling unit to prevent water WARNING! being removed from the trap when the A/C unit is Turn off electrical power at the fuse or running. service panel before making any electrical A drain line must be attached to the trap outlet connections. The ground connection must and pitched away from the unit a minimum of 1/8" be completed before making line voltage per foot to allow the condensate to flow away connections. Failure to do so can result in from the unit. electrical shock, severe personal injury or death. The dehumidifier must be installed so DUCTS that the electrical components are protected The unit is furnished with two beaded 8" round from water from any source. collars for duct connections to the inlet and the outlet of the dehumidifier. These are located inside the unit and must be attached to the unit by WARNING! the installer using screws and gasket or caulking. The cabinet must be permanently Center the collars over the inlet and outlet grounded. Connect the ground wire to the openings in the cabinet. Ground terminal provided in the unit. Failure to ground the cabinet can result in fire, Insulated flexible ducts in compliance with electrical shock, personal injury or death. Underwriter’s Laboratory’s (UL) Standard for Factory Made Duct Materials, UL-18 and installed The electrical supply requirements are listed on per the manufacturer’s recommendation should the unit rating plate and in the specification table be used to connect the dehumidifier to the air above. conditioner. The installation and connections must 4 Use a separate fused branch electrical circuit local building/electric codes, using copper containing a properly sized fuse or circuit breaker. conductors only. Run this circuit directly from the main circuit box to an electrical disconnect which must be readily (ALTERNATE) REMOTE DEHUMIDISTAT accessible and located within sight of the The dehumidifier is supplied with its own, self dehumidifier. Connect from the disconnect to the contained, dehumidistat control which includes an electrical connection within the dehumidifier air sampling sequence; however, the unit can also utilizing the hole sized for 1/2" conduit provided be controlled by a remote dehumidistat located in on the entering air end of the unit. a conditioned space. DO NOT LOCATE THE DEHUMIDISTAT IN THE DUCTWORK.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    12 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us