Digital Control Adapter Data Sheet Digital Control Adapter
Total Page:16
File Type:pdf, Size:1020Kb
Digital Control Adapter Data Sheet Digital Control Adapter TABLE OF CONTENTS 1 Description and Key Features 2 Ordering Information 3 Mechanical Drawing and Wiring Specifications 4 Lutron® EcoSystem Protocol 5 DMX512-A-RDM Protocol 6 Wiring Diagrams Lumenetix Inc. • 4742 Scotts Valley Dr. • Scotts Valley, CA 95066 877.805.7284 • www.lumenetix.com • [email protected] Lumenetix, araya5, Dynamic Dimming and SceneSet are registered trademarks of Lumenetix, Inc. © Lumenetix, Inc. 2019. UL Recognized Component Dry or Damp Locations Designed in California, USA Assembled in USA Designed in California, USA UL Recognized Component Assembled in USA Dry or Damp Locations Class 2 Input Class 2 Input UL Recognized Component ii | Digital Control Adapter Data Sheet RevisedDry 10.22.19 or Damp | Locations Specifications subject to change without notice Class 2 Input Digital Control Adapter 1 DESCRIPTION AND KEY FEATURES Description 5 The Digital Control Adapter (DCA) enables fixtures powered byaraya ® LED modules to be controlled by standard lighting protocols. The adapter converts standards-based lighting protocols to a digital link that connects to the araya5 modules. The standards supported are: • EcoSystem by Lutron® • DMX512-A-RDM (including Bluetooth) Key Features • 12V or 24V. • Compatible with araya5 CTM1 color tuning modules, and DDM1 dynamic dimming modules. • Enables Lutron EcoSystem and DMX512-A-RDM compatible product offerings. • Each adapter is addressable. • Controls continuous dimming from 100% - 1% in increments of 1%. • Controls continuous color tuning from: – 1650-4000K — CTM1B, Bluetooth-integrated – 1650-8000K — CTM1C, Bluetooth-integrated • Controls dimming from 3050K at full intensity to 1800K at 1% intensity: – DDM1B, Bluetooth-integrated – DDM1C, Bluetooth-integrated • DMX adapter enables dimming, color tuning, hue and saturation features. 3 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter 2 ORDERING INFORMATION General Specifications and Ordering Codes Power Connector Type 2 position Molex Pico-SPOX Wire Size 24 AWG Operating Voltage 12V DC to 24V DC Absolute Maximum Voltage 28V DC Power Consumption 0.25 W Reverse Voltage Protection 40V DC ESD protection Special handling not required Environment Operating Temperature 0° C to 65° C Location Type Dry Lutron® EcoSystem Input (DCA-1A)* (DISCONTINUED - NO LONGER AVAILABLE) Connector Type Refer to “Wiring Specifications” Section Wire Size 16 AWG solid wire (EcoSystem input); 24 AWG stranded wire (Lux output) Wiring Class EcoSystem Input: Class 1 or Class 2; LX Output: Class 2 Line Voltage Miswire Protection 277V AC (EcoSystem Input) DDM0 / DDM1 (1800 - 3050K): 45.020.008.04 (EAECOS1; one channel) Ordering Codes CTM0 / CTM1: 45.020.008.05 (EAECOS2; two channel) DMX Input (DCA-1B)* (DISCONTINUED - NO LONGER AVAILABLE) Connector Type Refer to “Wiring Specifications” Section Wire Size 24 AWG stranded wire (DMX input and Lux output) Wiring Class DMX Input: Class 1 or Class 2; LX Output: Class 2 DDM0 / DDM1 (1800 - 3050K); CTM0 / CTM1 (1650 - 4000K): 45.020.008.02 (EADDB-40-R) Ordering Codes CTM0 (2700 - 6000K): 45.020.008.03 (EADDB-60-R) Lutron® EcoSystem Input (DCA-2)** Connector Type Refer to “Wiring Specifications” Section Wire Size 24 AWG Wiring Class EcoSystem Input: Class 1 or Class 2; DMX Output: Class 2 Line Voltage Miswire Protection 277V AC (EcoSystem Input) DDM1B and DDM1C (Bluetooth-integrated): 80.005.001.02 (EAECOS1-G2; one channel) Ordering Codes CTM1B and CTM1C (Bluetooth-integrated): 80.005.002.02 (EAECOS2-G2; two channel) *LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE). **DMX Output is used with CTM 1B, CTM1C and DDM 1C. 4 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter 8 7 6 5 4 3 2 1 3 MECHANICAL DRAWING & WIRING SPECIFICATIONS D D 8 Mechanical Drawing7 6 5 4 3 2 1 2X 4.83 .19 D D C C 64.6 2.5 2X 4.83 32.3.19 1.27 C C 4 B 64.6 B .16 64.6 2.54 2.5 76.2 25.9 3.00 1.0 88.9 32.3 3.50 1.27 Side view – araya5 Digital Control Adapter Side view – araya5 Digital Control Adapter Side view – araya5 Digital Control Adapter ® ® UNLESS OTHERWISE SPECIFIED: NAME DATE ® (Lutron EcoSystem input) (DMX input) DIMENSIONS ARE IN MILLIMETERS DRAWN (Lutron EcoSystemLumenetix input) ® TOLERANCES: ® 4 CHECKED TITLE: B 64.6 ANGULAR: MACH 0.5 B ONE PLACE DECIMAL 0.5 A .16 DCA-1A DCA-1B ENG APPR. DCA-2 A 2.54 TWO PLACE DECIMAL 0.15 76.2 MFG APPR. 25.9 INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: ASME Y14.5 3.00 COMMENTS: EcoSystem1.0 THE INFORMATION CONTAINED IN THIS MATERIAL EcoSystemSIZE DWG. NO. DRAWING IS THE SOLE PROPERTY OF SEE NOTES REV Interface LUMENETIX. ANY REPRODUCTION IN 88.9 Interface PART OR AS A WHOLE WITHOUT THE FINISH Power Module WRITTEN PERMISSION OF LUMENETIX NEXT ASSY 3.50Power USEDModule ON DMX B Power Module IS PROHIBITED. NOT APPLICATION DO NOT SCALE DRAWING SCALE: 1:1 WEIGHT: SHEET 1 OF 1 NOT USED NOT 8 7 USED6 5 4 3 2 1 USED P2 M2 M4 P2 M2 M4 D1 D3 P2 M2 M4 E1 E2 P1 M1 M3 M5 P1 M1 M3 M5 D2 E1 E2 P1 M1 M3 M5 UNLESS OTHERWISE SPECIFIED: NAME DATE DIMENSIONS ARE IN MILLIMETERS DRAWN Lumenetix TOLERANCES: ANGULAR: MACH 0.5 CHECKED TITLE: ONE PLACE DECIMAL 0.5 A ENG APPR. A TWO PLACE DECIMAL 0.15 Wiring Specifications MFG APPR. INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: ASME Y14.5 COMMENTS: THE INFORMATION CONTAINED IN THIS MATERIAL SIZE DWG. NO. DRAWING IS THE SOLE PROPERTY OF SEE NOTES REV LUMENETIX. ANY REPRODUCTION IN Pin WirePART Color OR AS A WHOLE WITHOUT THE Pin FunctionFINISH Wiring Description WRITTEN PERMISSION OF LUMENETIX NEXT ASSY USED ON B IS PROHIBITED. APPLICATION DO NOT SCALE DRAWING SCALE: 1:1 WEIGHT: SHEET 1 OF 1 Lutron EcoSystem 2 Position Terminal Block 8 ® 7 E1 6 Violet 5 4 3 2 1 Interface Non-polarized Bus Terminal 16 AWG solid wire (Input) E2 Violet / White Lutron PN: C-CBL-216-GR-1 P1 Red Power 12V DC or 24V DC (+) 2 Position Molex Pico-SPOX Power Lumenetix PN: 28.002.001.01 P2 Black Power Common (-) Length: 610 mm (24 inches) M1 N/A Reserved for future use M2 N/A Reserved for future use 5 Position Molex Pico-SPOX Module Interface M3 Brown Digital Common Lumenetix PN: 28.020.002.01 (LX or DMX Output)* M4 Orange araya® Module Bus, Data - Length: 610 mm (24 inches) Option-1: White with Orange Stripe M5 araya® Module Bus, Data + (Option-2: Green) D1 Option-1: Brown (Option-2: Black) Digital Common 3 Position Molex Pico-SPOX 24 AWG stranded wire DMX Interface Option-1: White with Orange Stripe D2 DMX Data + Lumenetix PN Option-1: 28.020.001.02 (Input) (Option-2: Violet) (Lumenetix PN Option-2: 28.020.001.01) D3 Option-1: Orange (Option-2: Gray) DMX Data - Length: 610 mm (24 inches) CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. *LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE). DMX Output is used with CTM 1B, CTM1C and DDM 1C. 5 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter 4 LUTRON WIRING® ECOSYSTEM DIAGRAMS PROTOCOL 4.1Lutron Lutron® EcoSystem® EcoSystem Protocol Protocol PowerEcoSystem Module technology with is a controlEcoSystem method forR LEDs that provides LQSE-2ECO-Daddressing of individual fi xtures and status feedback. ThisEcoSystem makes it easy toR Controllerdigitally assign one or many fi xtures without complicated wiring. This opens up an entire suite of energy-saving, system-monitoring and system-control schemes where the design, setup and rezoning are all done within software, making the electrical and control design simple. 369611b 1 10.22.13 Power5 Module with EcoSystemR The araya® modules attached to different interface boards can be controlled independently or assigned to a single group by the EcoSystem controller. TheThe EcoSystemPower Module control is withresponsible EcoSystem for saving Rany unit confiis guration a settings. Once an interface board is assigned a pair of addresses, assigned addresses are DIN-railsaved in NVRAM.mounted During EcoSystem the EcoSystem® Loop discovery controller process, the for user pairs the desired dimming control in the controller to the Dim channel address in the EcoSysteinterface board.mR ballasts,The same applies drivers for theand CCT devices. channel. It provides EcoSystemR Loop power and control for A • 1 pair 16AWG Eco Loop, 900 feet (fi eld wiring). v. two independent EcoSystemR Loops with up to 64 QS ECO 1 ECO 2 NEC® Class 2 NEC® MUX MUX COM ballasts• Maximu or driversm of 64 addresses each. on each loop. IEC PELV Class 2 500-15537 Re Ta > 65 ºC Power Module with EcoSystem® | Módulo de Potencia con EcoSystem® | Module d’Alimentation avec EcoSystem® Test LQSE-2ECO-D Prueba 120 V~ 50/60 Hz 120 mA 1.800.523.9466 Tester 243C IND.CONT.EQ. u ~ FeaturesEcoSystem Control Systems (recommended list)* 230 V 50/60 Hz 80 mA Z096 +44.(0)20.7702.0657 Patent: 7,391,297 • Provides EcoSystemR Loop power for two loops LN Ta ≤ 65 °C 8 mm 65/75 ºC Cu Al 0,5 N•m (5 in-lbs) www.lutron.com ofQuantum EcoSystem SystemR ballasts or drivers (up to 250 mA perHomeWorks loop). QS • PowerGrafi k Eyefailur QSe Control memory Unit retainswith EcoSystem control unit programming in the event of a power loss.