Digital Control Adapter Data Sheet Digital Control Adapter

TABLE OF CONTENTS

1 Description and Key Features

2 Ordering Information

3 Mechanical Drawing and Wiring Specifications

4 Lutron® EcoSystem Protocol

5 DMX512-A-RDM Protocol

6 Wiring Diagrams

Lumenetix Inc. • 4742 Scotts Valley Dr. • Scotts Valley, CA 95066 877.805.7284 • www.lumenetix.com • [email protected] Lumenetix, araya5, Dynamic Dimming and SceneSet are registered trademarks of Lumenetix, Inc. © Lumenetix, Inc. 2019.

UL Recognized Component Dry or Damp Locations Designed in California, USA Assembled in USA Designed in California, USA UL Recognized Component Assembled in USA Dry or Damp Locations Class 2 Input Class 2 Input UL Recognized Component ii | Digital Control Adapter Data Sheet RevisedDry 10.22.19 or Damp | Locations Specifications subject to change without notice Class 2 Input

Digital Control Adapter

1 DESCRIPTION AND KEY FEATURES

Description

5 The Digital Control Adapter (DCA) enables fixtures powered byaraya ® LED modules to be controlled by standard lighting protocols. The adapter converts standards-based lighting protocols to a digital link that connects to the araya5 modules. The standards supported are:

• EcoSystem by Lutron® • DMX512-A-RDM (including Bluetooth)

Key Features • 12V or 24V. • Compatible with araya5 CTM1 color tuning modules, and DDM1 dynamic dimming modules. • Enables Lutron EcoSystem and DMX512-A-RDM compatible product offerings. • Each adapter is addressable. • Controls continuous dimming from 100% - 1% in increments of 1%. • Controls continuous color tuning from: – 1650-4000K — CTM1B, Bluetooth-integrated – 1650-8000K — CTM1C, Bluetooth-integrated • Controls dimming from 3050K at full intensity to 1800K at 1% intensity: – DDM1B, Bluetooth-integrated – DDM1C, Bluetooth-integrated • DMX adapter enables dimming, color tuning, hue and saturation features.

3 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

2 ORDERING INFORMATION

General Specifications and Ordering Codes

Power Connector Type 2 position Molex Pico-SPOX Wire Size 24 AWG Operating Voltage 12V DC to 24V DC Absolute Maximum Voltage 28V DC Power Consumption 0.25 W Reverse Voltage Protection 40V DC ESD protection Special handling not required Environment Operating Temperature 0° C to 65° C Location Type Dry

Lutron® EcoSystem Input (DCA-1A)* (DISCONTINUED - NO LONGER AVAILABLE) Connector Type Refer to “Wiring Specifications” Section Wire Size 16 AWG solid wire (EcoSystem input); 24 AWG stranded wire (Lux output) Wiring Class EcoSystem Input: Class 1 or Class 2; LX Output: Class 2 Line Voltage Miswire Protection 277V AC (EcoSystem Input) DDM0 / DDM1 (1800 - 3050K): 45.020.008.04 (EAECOS1; one channel) Ordering Codes CTM0 / CTM1: 45.020.008.05 (EAECOS2; two channel) DMX Input (DCA-1B)* (DISCONTINUED - NO LONGER AVAILABLE) Connector Type Refer to “Wiring Specifications” Section Wire Size 24 AWG stranded wire (DMX input and Lux output) Wiring Class DMX Input: Class 1 or Class 2; LX Output: Class 2 DDM0 / DDM1 (1800 - 3050K); CTM0 / CTM1 (1650 - 4000K): 45.020.008.02 (EADDB-40-R) Ordering Codes CTM0 (2700 - 6000K): 45.020.008.03 (EADDB-60-R)

Lutron® EcoSystem Input (DCA-2)** Connector Type Refer to “Wiring Specifications” Section Wire Size 24 AWG Wiring Class EcoSystem Input: Class 1 or Class 2; DMX Output: Class 2 Line Voltage Miswire Protection 277V AC (EcoSystem Input) DDM1B and DDM1C (Bluetooth-integrated): 80.005.001.02 (EAECOS1-G2; one channel) Ordering Codes CTM1B and CTM1C (Bluetooth-integrated): 80.005.002.02 (EAECOS2-G2; two channel)

*LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE). **DMX Output is used with CTM 1B, CTM1C and DDM 1C.

4 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter 8 7 6 5 4 3 2 1

3 MECHANICAL DRAWING & WIRING SPECIFICATIONS D D

8 Mechanical Drawing7 6 5 4 3 2 1

2X 4.83 .19

D D

C C 64.6 2.5

2X 4.83 32.3.19 1.27

C C 4 B 64.6 B .16 64.6 2.54 2.5 76.2 25.9 3.00 1.0 88.9 32.3 3.50 1.27

Side view – araya5 Digital Control Adapter Side view – araya5 Digital Control Adapter Side view – araya5 Digital Control Adapter ® ® UNLESS OTHERWISE SPECIFIED: NAME DATE ® (Lutron EcoSystem input) (DMX input) DIMENSIONS ARE IN MILLIMETERS DRAWN (Lutron EcoSystemLumenetix input) ® TOLERANCES: ® 4 CHECKED TITLE: B 64.6 ANGULAR: MACH 0.5 B ONE PLACE DECIMAL 0.5 A .16 DCA-1A DCA-1B ENG APPR. DCA-2 A 2.54 TWO PLACE DECIMAL 0.15 76.2 MFG APPR. 25.9 INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: ASME Y14.5 3.00 COMMENTS: EcoSystem1.0 THE INFORMATION CONTAINED IN THIS MATERIAL EcoSystemSIZE DWG. NO. DRAWING IS THE SOLE PROPERTY OF SEE NOTES REV Interface LUMENETIX. ANY REPRODUCTION IN 88.9 Interface PART OR AS A WHOLE WITHOUT THE FINISH Power Module WRITTEN PERMISSION OF LUMENETIX NEXT ASSY 3.50Power USEDModule ON DMX B Power Module IS PROHIBITED. NOT APPLICATION DO NOT SCALE DRAWING SCALE: 1:1 WEIGHT: SHEET 1 OF 1 NOT USED NOT 8 7 USED6 5 4 3 2 1 USED

P2 M2 M4 P2 M2 M4 D1 D3 P2 M2 M4 E1 E2 P1 M1 M3 M5 P1 M1 M3 M5 D2 E1 E2 P1 M1 M3 M5

UNLESS OTHERWISE SPECIFIED: NAME DATE

DIMENSIONS ARE IN MILLIMETERS DRAWN Lumenetix TOLERANCES: ANGULAR: MACH 0.5 CHECKED TITLE: ONE PLACE DECIMAL 0.5 A ENG APPR. A TWO PLACE DECIMAL 0.15 Wiring Specifications MFG APPR. INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: ASME Y14.5 COMMENTS: THE INFORMATION CONTAINED IN THIS MATERIAL SIZE DWG. NO. DRAWING IS THE SOLE PROPERTY OF SEE NOTES REV LUMENETIX. ANY REPRODUCTION IN Pin WirePART Color OR AS A WHOLE WITHOUT THE Pin FunctionFINISH Wiring Description WRITTEN PERMISSION OF LUMENETIX NEXT ASSY USED ON B IS PROHIBITED. APPLICATION DO NOT SCALE DRAWING SCALE: 1:1 WEIGHT: SHEET 1 OF 1 Lutron EcoSystem 2 Position Terminal Block 8 ® 7 E1 6 Violet 5 4 3 2 1 Interface Non-polarized Terminal 16 AWG solid wire (Input) E2 Violet / White Lutron PN: C-CBL-216-GR-1

P1 Red Power 12V DC or 24V DC (+) 2 Position Molex Pico-SPOX Power Lumenetix PN: 28.002.001.01 P2 Black Power Common (-) Length: 610 mm (24 inches) M1 N/A Reserved for future use M2 N/A Reserved for future use 5 Position Molex Pico-SPOX Module Interface M3 Brown Digital Common Lumenetix PN: 28.020.002.01 (LX or DMX Output)* M4 Orange araya® Module Bus, Data - Length: 610 mm (24 inches) Option-1: White with Orange Stripe M5 araya® Module Bus, Data + (Option-2: Green) D1 Option-1: Brown (Option-2: Black) Digital Common 3 Position Molex Pico-SPOX 24 AWG stranded wire DMX Interface Option-1: White with Orange Stripe D2 DMX Data + Lumenetix PN Option-1: 28.020.001.02 (Input) (Option-2: Violet) (Lumenetix PN Option-2: 28.020.001.01) D3 Option-1: Orange (Option-2: Gray) DMX Data - Length: 610 mm (24 inches)

CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. *LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE). DMX Output is used with CTM 1B, CTM1C and DDM 1C.

5 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4 LUTRON WIRING® ECOSYSTEM DIAGRAMS PROTOCOL

4.1Lutron Lutron® EcoSystem® EcoSystem Protocol Protocol PowerEcoSystem Module technology with is a controlEcoSystem method forR LEDs that provides LQSE-2ECO-Daddressing of individual fi xtures and status feedback. ThisEcoSystem makes it easy toR Controllerdigitally assign one or many fi xtures without complicated wiring. This opens up an entire suite of energy-saving, system-monitoring and system-control schemes where the design, setup and rezoning are all done within software, making the electrical and control design simple. 369611b 1 10.22.13

Power5 Module with EcoSystemR The araya® modules attached to different interface boards can be controlled independently or assigned to a single group by the EcoSystem controller. TheThe EcoSystemPower Module control is withresponsible EcoSystem for saving Rany unit confiis guration a settings. Once an interface board is assigned a pair of addresses, assigned addresses are DIN-railsaved in NVRAM.mounted During EcoSystem the EcoSystem® Loop discovery controller process, the for user pairs the desired dimming control in the controller to the Dim channel address in the EcoSysteinterface board.mR ballasts,The same applies drivers for theand CCT devices. channel. It provides EcoSystemR Loop power and control for A • 1 pair 16AWG Eco Loop, 900 feet (fi eld wiring). v. two independent EcoSystemR Loops with up to 64 QS ECO 1 ECO 2

NEC® Class 2 NEC® MUX MUX COM ballasts• Maximu or driversm of 64 addresses each. on each loop. IEC PELV Class 2 500-15537 Re

Ta > 65 ºC Power Module with EcoSystem® | Módulo de Potencia con EcoSystem® | Module d’Alimentation avec EcoSystem® Test LQSE-2ECO-D Prueba 120 V~ 50/60 Hz 120 mA 1.800.523.9466 Tester 243C IND.CONT.EQ. u ~ FeaturesEcoSystem Control Systems (recommended list)* 230 V 50/60 Hz 80 mA Z096 +44.(0)20.7702.0657 Patent: 7,391,297 • Provides EcoSystemR Loop power for two loops LN Ta ≤ 65 °C 8 mm 65/75 ºC Cu Al 0,5 N•m (5 in-lbs) www.lutron.com ofQuantum EcoSystem SystemR ballasts or drivers (up to 250 mA perHomeWorks loop). QS • PowerGrafi k Eyefailur QSe Control memory Unit retainswith EcoSystem control unit programming in the event of a power loss. EnergiSavr Node with EcoSystem • Includes QS Link for connection to a HomeWorksPower ModuleR with QS EcoSystemsystem. • Power Module with EcoSystemR unit can be used in a*Recommendations HomeWorksR QS are systemsubject to to change. control Consult and your manage Lumenetix representative for the most updated list. light in an entire home or building.

Lutron EcoSystem Controller Example Lutron EcoSystem Example Eco Loop 1 Up to 64 devices on Fixture* Fixture* each loop for Eco Loop 2 Eco-1, and up to 32 Fixture* Fixture* devices on each loop for HomeWorksR QS QS Eco-2 Wallstation Contact HomeWorksR QS Power Power Closure GRAFIK 120 / 230 V~ Module with Module Processor Interface EyeR QS Control Power Up to 100 EcoSystem® total QS QS Link devices SivoiaR QS Shade / Drapery

QS Power *Fixture refers to a luminaire with one Lumenetix module, and Supply with one address (DDM) or two addresses (CTM).

6 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice

® Specification Submittal page 1 Job Name: Model Numbers:

Job Number: Digital Control Adapter

4LUTRON WIRING® ECOSYSTEM DIAGRAMS PROTOCOL

4.1.1Lutron Lutron® EcoSystem® EcoSystem Field Wiring Field Wiring • EcoSystem Digital Loop can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring fl exibility..

• The Loop is polarity insensitive and can be wired in any topology..

• Consult all national and local electrical codes for separation requirements..

Wire Gauge Maximum EcoSystem-Compliant Loop Wire Length 4.0 mm2 (12 AWG) 671 m (2200 ft) 2.5 mm2 (14 AWG) 427 m (1400 ft) 1.5 mm2 (16 AWG) 275 m (900 ft) 1.0 mm2 (18 AWG) 175 m (570 ft)

Drain Wire Connections Drain wire connections are required as follows.

Shielding To add another level of protection from electromagnetic noise, a grounded shield is added over the wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the fi eld. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate.

Method-1 A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the fi eld end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop.

Method-2 A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop.

7 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4 DMX512-A WIRING DIAGRAMS PROTOCOL

4.2DMX512-A DMX512-A Protocol Protocol DMX512-A is an acronym for Digital Multiplex, a used to remotely control lighting and intelligent fi xtures. It is designed to provide a common communications standard between these lighting devices regardless of the manufacturer. The 512-A after the DMX refers to the number of control channels used on one network segment (often called a ‘universe’) of devices. In a simple dimming system, one channel controls the intensity of the fi xture. A single intelligent fi xture such as the araya5 requires several channels to control its various parameters (one channel each for DIM, CCT, SAT, HUE).

DMX512A Specifi cations • DMX 512-A (Controller). • A universe is 512 Channels. • DMX value is between 0 and 255, where 0 is off and 255 is full on. • The maximum number of devices in a daisy-chain wire run is 32, which include the controller and opto-splitter. • The maximum network wire run is a distance of up to 1600 feet for non-RDM systems and up to 1000 feet for RDM systems. • One device functions as the master (DMX controller) on a network, while the rest function as slaves (mergers, splitters, intelligent fi xtures, etc.). • Only the controller (master) transmits over the network, and all fi xtures receive the same data. • The fi nal device in the daisy-chain must be terminated with a 120 ohm resistor between DMX+ and DMX- pins. • It is recommended that the terminator for the fi nal device be located in the control panel, if it falls within the recommended wiring distance. • All wiring must be in a continuous run and daisy-chained. • Star wiring is only allowed in conjunction with an opto-splitter. • Do not run DMX control cable in close proximity to AC power lines. EM spikes from switching of high-current devices such as HVAC equipment or generators will induce noise into the DMX cable. • The shield must be carried through between modules and properly grounded at one point only. • Connections to DMX512-A-RDM accessory board: wire size to be 24AWG, and solid or stranded cables may be used. Stranded wire used must be tinned or installed with ferule connector.

RDM DMX512-A control protocol that enables Remote Device Management for two-way communications for confi guration, monitoring and system setup. Allows two way communication between lighting controller and the fi xtures. Allows for remote setting of DMX start addressing. RDM signals are sent back the other way, but not constantly. Controller can ask one or more devices for query feedback. RDM packets are inserted in-between the existing DMX data packets being used to control the lighting. The DMX Control Console will broadcast up to 512 channels over one DMX cable (max. run of 1000 feet for RDM). Some of these channels may not be used, but will still be transmitted, as required by the protocol. It must be set to a desired channel (001, 002. 003. 004, etc.) to control the connected light fi xture. This is usually accomplished using RDM. This desired ‘channel’ is commonly known as the DMX address. When addressing fi xtures, it is not recommended to skip addresses.

When RDM is not available with the control system, it is permissible to use the Lumenetix commissioning tool (the araya5 Tunable Color 2.0 iOS App) to set the address of the slots. The instructions to confi gure the DMX channels can be found in the separate araya5 Tunable Color Instruction Manual.

The DMX512-A interface follows the ANSI E1.11-2008 (R21013) standard. Four address slots are allocated to each interface board and control the Dim level, CCT, Saturation and Hue of the araya5 modules connected to the board.

Deault DMX512-A Slot Allocation

Slot Function 1 Dim Level 2 CCT 3 Saturation Level 4 Hue

8 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4DMX512-A WIRING DIAGRAMSPROTOCOL

4.2.1DMX512-A DMX512-A Electrical Electrical Specifi Specifications cations

Parameter Range Remars ESD Protection ±15KV (air), ±8KV (conducted) Per IEC 61000-4-2 Termination Recommended The DMX512 bus termination rules apply Directionality Receive only Frequency stability ±20ppm Load per port 1/256 1/8 of Nominal RS-485

Isolation 3KVrms

DMX512-A Control Systems (recommended list) Choreo Cognito Crestron Greenlight System Entec ETC Mosaic ETC Paradigm Fresco Interactive Technologies Lutron HomeWorks QS Lutron Quantum Nicolaudie Pathway Connectivity Pharos Traxon Ecue Vantage Controls

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list.

DMX512-A Recommended Internal Field Wiring TMB Cale ProPlex DMX PC224T 2-pair DMX512 cable, overall foil and braid shielding with drain wire. UV and fungus resistant. Fully rated for installations, yet easy handling for light duty portable applications. PC224TW Same as above, with white jacket.

For use as DMX inout under one acet PC244T Two individually shielded pairs and drain wires. UV resistant. Color coded foil shielding for easy reference.

9 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4DMX512-A WIRING DIAGRAMSPROTOCOL

4.2.2DMX512-A DMX512-A Recommended Recommended Field Wiring Field Wiring Liberty 24-2P-485 (Non-Plenum), 24 AWG, 2 pair dual 120 ohm, 11.2 pf/ft low capacitance (Wago, XLR and PHX connectors) Liberty 24-2P-P485 (Plenum), 24 AWG, 2 pair dual 120 ohm, 11.2 pf/ft low capacitance (XLR and PHX connectors) Belden #9842 (Non-Plenum), 24 AWG, 2 pair dual shielded 120 ohm, 12.8 pf/ft low capacitance (XLR and PHX connectors) Belden #89842 (Plenum), 24 AWG, 2 pair dual shielded 120 ohm, 12.8 pf/ft low capacitance (XLR and PHX connectors) Please refer to wire manufacturer’s lighting catalog for and/equals as required by code. Category Wire or Eual The Entertainment Services and Technology Association (ESTA) does not defi ne a maximum run length for DMX over Cat5 since many factors will affect the maximum run length, such as number of devices, number of splices in the cable, the strength of the DMX transmitter(s), if Remote Device Management (RDM) is being used, and sources of interference. ESTA does state (again, in ANSI E1.21-2): “A properly selected and installed DMX512 cable should provide acceptable signal strength for runs of 300m (1000ft). Please note that the technical requirements, such as run-length and topology for other networking technologies, such as , should be considered if using the installed cable for another networking technology in the future is anticipated.” Cat5 or equivalent is not preferred as a portable cable since it is not as rugged as other DMX cables. Male RJ45 connectors are especially prone to breakage over repeated re-connections.

LUMENETIX RECOMMENDATION CAT 5E -150 FEET CRESTRON DM-CBL-8G-NP DM-CBL-8G-P

CAT 7- 330 FEET CRESTRON DM-CBL-ULTRA-NP DM-CBL-ULTRA-P DMX512-A Recommended Field Connectors (or Eual) WAGO 221 PHOENIX CONTACT XLR NEUTRIK CRESTRON RJ45 DM -8G-CONN RJ45 IDC DM-CONN

DMX512-A Wiring Connections 3-pin XLR 5-Pin XLR 5-Pin PHX Signal Description Pin Colors (4-Pair Cable) Pin Colors (2-Pair Cable) connector connector connector Signal Common White/Brown and Brown White/Blue and Blue 1 1 1 Data (-) Primary Data Link Orange Orange 2 2 2 Data (+) Primary Data Link White/Orange White/Orange 3 3 3 Data2 (-), or not used Optional Secondary Data Link 4 4 Data2 (+), or not used Optional Secondary Data Link 5 5

XLR Connectors (5-Pin) R-45 Connector Pin-Out (T58B)

- +

10 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4DMX512-A WIRING DIAGRAMSPROTOCOL

4.2.3DMX512-A DMX512-A Controller Controller Example Example DMX512A Example DMX Loop 1 Up to 30 devices on DMX Loop 2 each loop

Wallstation Contact Power Processor Closure Touch Module Interface Panel DMX RDM Merger / 120 / 230 V~ Controller Splitter Control Power total Bus devices

Shade / Drapery

Power *Fixture refers to a luminaire with one Lumenetix module, and Supply with one address (DDM) or four addresses (CTM).

DMX512-A Drain Wire Connections

Drain wire connections are required as follows.

Shielding To add another level of protection from electromagnetic noise, a grounded shield is added over the twisted pair wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the fi eld. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate.

Method-1 A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the fi eld end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop.

Method-2 A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop.

11 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4LUTRON WIRING® ECOSYSTEM DIAGRAMS WIRING DIAGRAMS

Lutron4.3.1 Lutron EcoSystem® EcoSystem Input; Digital Input; ControlDCA-1A Adapter (24V DC) (DCA) DDM0 DDM0(one channel) (one channel); CTM0 CTM0 (two channel)(two channel) 24V

Notes 1. 24V power (red/black) is Class-2 rated.

5 2.Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for EcoSystem inputs. 4. DCA may be installed in the luminaire only. 5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit. 6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit. 7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K and 2700 - 6000K. 9.CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 10.LX Output used with this system.

JUNCTION BOX Fixture manufacturer to provide minimum 18 AWG of Lutron EcoSystem wire tail (labeled E1 and E2) to junction box. Consult Lutron for eld wiring. Violet / White Violet Stripes E1 E2 Lutron EcoSystem Controller White / White Orange Brown Orange

NOT USED Adapter is con gured at OEM factory for EcoSystem inputs.

PN: 28.002.001.01 Digital Control Adapter

PN: 28.020.002.01 FIXTURE R AVAILABLE Brown is Digital Common. Orange is Data Negative. White with Orange Stripe is Data Positive. NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly. CTM0 NGE DDM0 + – PN: 28.002.001.01 Red Black PN: 28.002.002.01 24V DC, Class 2 DCA-1A AND DCA-1B DISCONTINUEDAC to DC Power Supply - White/Blue and Gray/Violet 0-10V wires are tied together White Black

NO LO Line in Voltage (refer to power supply) The Constant Hot/Live must not be Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

12 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4LUTRON WIRING® ECOSYSTEM DIAGRAMS WIRING DIAGRAMS

Lutron4.3.2 Lutron EcoSystem® EcoSystem Input; Digital Input; ControlDCA-1A Adapter(12V DC) (DCA) DDM1 DDM1(one channel) (one channel); CTM1 CTM1 (two channel)(two channel) 12V

Notes 1. 12V power (red/black) is Class-2 rated.

5 2.Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for EcoSystem inputs. 4. DCA may be installed in the luminaire only. 5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit. 6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit. 7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K. 9.CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 10.LX Output used with this system. JUNCTION BOX Fixture manufacturer to provide minimum 18 AWG of Lutron EcoSystem wire tail (labeled E1 and E2) to junction box. Consult Lutron for eld wiring. Violet / White Violet Stripes E1 E2 Lutron EcoSystem Controller Brown Orange / White Orange

NOT USED Adapter is con gured at OEM factory for EcoSystem inputs.

Digital Control Adapter

PN: 28.020.002.01

R AVAILABLEPN: 28.002.001.01 Brown is Digital Common. Orange is Data Negative. White with Orange Stripe is Data Positive. NOTE: This wire may be shipped in GREEN color in White/BlueNGE and Gray/Violet 0-10V wires are tied together some existing versions of this cable assembly. PN: 28.002.002.01 + – Red

FIXTURE Black 12V DC, Class 2 DCA-1A AND DCA-1B DISCONTINUEDAC to DC Power Supply - CTM1 White DDM1 Black NO LO Line in Voltage (refer to power supply) The Constant Hot/Live must not be PN: 28.002.001.01 Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

13 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4DMX512-A WIRING DIAGRAMSWIRING DIAGRAMS

DMX4.4.1 Input;DMX Input;Digital DCA-1B Control (24V Adapter DC) (DCA) DDM0 DDM0; CTM0 CTM0 24V

Notes 1.24V power (red/black) is Class-2 rated.

5 2.Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for DMX (including Bluetooth) inputs. 4. DCA may be installed in the luminaire only. 5. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 6.LX Output used with this system.

JUNCTION BOX For DMX inputs: OPTION-1 OPTION-2 Brown is Digital Common. Black is Digital Common. White with Orange Stripe is Data Positive. Violet is Data Positive. Orange is Data Negative. Gray is Data Negative.

DMX (incl. Bluetooth) PN Option-1: Brown Orange White / White Orange 28.020.001.02 PN Option-2: 28.020.001.01 White / White Orange Brown Orange NOT USED

PN: 28.002.001.01 Digital Control Adapter

PN: 28.020.002.01

FIXTURE

R AVAILABLE Brown is Digital Common. Orange is Data Negative. White with Orange Stripe is Data Positive. NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

CTM0 DDM0 NGE + – PN: 28.002.001.01 Red Black PN: 28.002.002.01 24V DC, Class 2 AC to DC Power Supply DCA-1A ANDWhite/Blue andDCA-1B Gray/Violet DISCONTINUED - 0-10V wires are tied together White Black

Line in Voltage NO LO (refer to power supply) The Constant Hot/Live must not be Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

14 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4DMX512-A WIRING DIAGRAMSWIRING DIAGRAMS

DMX4.4.2 Input;DMX Input;Digital DCA-1B Control (12V Adapter DC) (DCA) - DDM1 DDM1; CTM1 CTM1 12V

Notes 1. 12V power (red/black) is Class-2 rated.

5 2. Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for DMX (including Bluetooth) inputs. 4. DCA may be installed in the luminaire only. 5. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 6. LX Output used with this system.

JUNCTION BOX For DMX inputs: OPTION-1 OPTION-2 Brown is Digital Common. Black is Digital Common. White with Orange Stripe is Data Positive. Violet is Data Positive. Orange is Data Negative. Gray is Data Negative. DISCONTINUEDDMX (incl. Bluetooth) Brown Orange White / White Orange PN Option-1: 28.020.001.02 PN Option-2: 28.020.001.01 Brown Orange / White Orange NOT USED

DCA-1B Digital Control Adapter AVAILABLE PN: 28.020.002.01 PN: 28.002.001.01 Brown is Digital Common. AND Orange is Data Negative. White with Orange Stripe is Data Positive. NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly. White/Blue and Gray/Violet 0-10V wires are tied together

PN: 28.002.002.01 + – Red

FIXTURE Black LONGER 12V DC, Class 2 AC to DC Power Supply DCA-1ACTM1 White DDM1 Black Line in Voltage NO (refer to power supply) The Constant Hot/Live must not be PN: 28.002.001.01 Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

15 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4 WIRING DIAGRAMS LUTRON® ECOSYSTEM WIRING DIAGRAMS 4.5.1 Lutron EcoSystem Input; DCA-2 (24V DC) Lutron EcoSystem® Input; Digital Control Adapter (DCA) DDM1C, Bluetooth-integrated (one channel) DDM1C (one channel) CTM1C (two channel) 24V CTM1C, Bluetooth-integrated (two channel) Notes 1. 24V power (red/black) is Class-2 rated.

5 2. Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8. 4. DCA may be installed in the luminaire only. 5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit. 6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit. 7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 8000K. 9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 10. DMX Output used with this system. JUNCTION BOX Fixture manufacturer to provide minimum 18 AWG of Lutron EcoSystem wire tail (labeled E1 and E2) to junction box. Consult Lutron for eld wiring. Violet / White Violet Stripes E1 E2 Lutron EcoSystem Controller Brown Orange / White Orange

NOT USED Adapter is con gured at OEM factory for EcoSystem inputs.

Digital Control Adapter

PN: 28.020.002.01 Minimum requirement is a DMX type wire. PN: 28.002.001.01

Brown is Digital Common. Orange is Data Negative. White with Orange Stripe is Data Positive. White/Blue and Gray/Violet 0-10V wires can be tied NOTE: This wire may be shipped in GREEN color in together or left open. some existing versions of this cable assembly. PN: 28.002.002.01 + – Red

FIXTURE Black 24V DC, Class 2 AC to DC Power Supply CTM1 White DDM1 Black Line in Voltage (refer to power supply) The Constant Hot/Live must not be PN: 28.002.001.01 Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

16 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4 WIRING DIAGRAMS LUTRON® ECOSYSTEM WIRING DIAGRAMS 4.5.2 Lutron EcoSystem Input; DCA-2 (12V DC) Lutron EcoSystem® Input; Digital Control Adapter (DCA) DDM1C, Bluetooth-integrated (one channel) DDM1C (one channel) CTM1C (two channel) 12V CTM1C, Bluetooth-integrated (two channel) Notes 1. 12V power (red/black) is Class-2 rated.

5 2. Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8. 4. DCA may be installed in the luminaire only. 5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit. 6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit. 7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 8000K. 9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 10. DMX Output used with this system. JUNCTION BOX Fixture manufacturer to provide minimum 18 AWG of Lutron EcoSystem wire tail (labeled E1 and E2) to junction box. Consult Lutron for eld wiring. Violet / White Violet Stripes E1 E2 Lutron EcoSystem Controller Brown Orange / White Orange

NOT USED Adapter is con gured at OEM factory for EcoSystem inputs.

Digital Control Adapter

PN: 28.020.002.01 Minimum requirement is a DMX type wire. PN: 28.002.001.01 Brown is Digital Common. Orange is Data Negative. White with Orange Stripe is Data Positive. NOTE: This wire may be shipped in GREEN color in White/Blue and Gray/Violet 0-10V wires can be tied some existing versions of this cable assembly. together or left open. PN: 28.002.002.01 + – Red

FIXTURE Black 12V DC, Class 2 AC to DC Power Supply CTM1 White DDM1 Black Line in Voltage (refer to power supply) The Constant Hot/Live must not be PN: 28.002.001.01 Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

17 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Digital Control Adapter

4 WIRING DIAGRAMS LUTRON® ECOSYSTEM WIRING DIAGRAMS 4.5.3 Lutron EcoSystem Input; DCA-2 (12V DC) Lutron EcoSystem® Input; Digital Control Adapter (DCA) DDM1B, Bluetooth-integrated (one channel) DDM1B (one channel) CTM1B (two channel) 12V CTM1B, Bluetooth-integrated (two channel) Notes 1. 12V power (red/black) is Class-2 rated.

5 2. Module Data +/- (white with orange stripe/orange) to araya® modules is Class-2 rated. 3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8. 4. DCA may be installed in the luminaire only. 5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit. 6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit. 7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K. 9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. 10. DMX Output used with this system. JUNCTION BOX Fixture manufacturer to provide minimum 18 AWG of Lutron EcoSystem wire tail (labeled E1 and E2) to junction box. Consult Lutron for eld wiring. Violet / White Violet Stripes E1 E2 Lutron EcoSystem Controller Brown Orange / White Orange

NOT USED Adapter is con gured at OEM factory for EcoSystem inputs.

Digital Control Adapter

PN: 28.020.002.01

PN: 28.002.001.01 Brown is Digital Common. Orange is Data Negative. White with Orange Stripe is Data Positive. NOTE: This wire may be shipped in GREEN color in White/Blue and Gray/Violet 0-10V wires are tied together some existing versions of this cable assembly.

PN: 28.002.002.01 + – Red

FIXTURE Black 12V DC, Class 2 AC to DC Power Supply CTM1 White DDM1 Black Line in Voltage (refer to power supply) The Constant Hot/Live must not be PN: 28.002.001.01 Neutral Hot wired to a switching device. This may be put on a relay for maintenance.

18 | Digital Control Adapter Data Sheet Revised 10.22.19 | Specifications subject to change without notice Lumenetix Inc. 4742 Scotts Valley Drive Scotts Valley, CA 95066 877.805.7284 www.lumenetix.com