Catalog C-006 Rev A Positronic Provides CompleteMission Statement Capability “To utilize product �lexibility and application Experience assistance to present quality interconnect solutions • Founded in 1966 which represent value to customers worldwide.” • Involvement in the development of international connector specifi cations through EIA®, IEC and ISO as well as PICMG®. • Introduction of new and unique connector products to the electronics industry. • Patent holder for many unique connector features and techniques. • Vertically integrated manufacturing – raw materials to fi nished connectors. Technology • Expertise with solid machined contacts provides a variety of high reliability connectors including high current density power connectors. • Quality Assurance lab is capable of testing to IEC, EIA, UL, CUL, military and customer-specifi ed requirements. • In-house design and development of connectors based on market need or individual customer requirements. • Internal manufacturing capabilities include automatic precision contact machining, injection molding, stamping, plating operations and connector assembly. • Manufacturing locations in southwest , U.S.A. (headquarters); , , , , and . Total square footage: 407,441. Support • Quality Systems: Select locations qualifi ed to ISO 9001, ISO 14001, AS9100, MIL-STD-790 and customer “dock to stock” programs. Applicable products qualifi ed to MIL-DTL-24308, SAE AS39029, DSCC 85039, MIL-DTL-28748, Space D32, GSFC S-311-P-4 and GSFC S-311-P-10. • Compliance to a variety of international and customer specifi c environmental requirements. • Large in-house inventory of fi nished connectors. Customer specifi c stocking programs. • Factory direct technical sales support in major cities worldwide. • One-on-one customer support from worldwide factory locations. • World class web site. • Value-added solutions and willingness to develop custom products with reasonable price and delivery. Regional Headquarters Spring�ield, MO Auch, France Singapore

Products described within this catalog may be Positronic Industries’ FEDERAL SUPPLY CODE (Cage Code) protected by one or more of the following US patents: FOR MANUFACTURERS is 28198 #4,900,261 #5,255,580 #5,329,697 #6,260,268 #6,835,079 #7,115,002 Unless otherwise speci ed, dimensional tolerances are: Patented in Canada, 1992 Other Patents Pending 1) ±0.001 inches [0.03 mm] for male contact mating diameters. 2) ±0.003 inches [0.08 mm] for contact termination diameters. POSITRONIC® IS AN ITAR REGISTERED COMPANY 3) ±0.005 inches [0.13 mm] for all other diameters. 4) ±0.015 inches [0.38 mm] for all other dimensions.

Information in this catalog is proprietary to Positronic and its subsidiaries. Positronic believes the data contained herein to be reliable. Since the technical information is given free of charge, the user employs such information at his own discretion and risk. Positronic Industries assumes no responsibility for results obtained or damages incurred from use of such information in whole or in part. The following trademarks are registered to Positronic Industries, Inc. in the and many other countries: Positronic Industries, Inc.®, Positronic®, Connector Excellence®, P+ logo®, PosiBand®, PosiShop®, Positronic Global Connector Solutions®, Global Connector Solutions®. The color blue as it appears on various connectors is a trademark of Positronic Industries, Inc., Registered in U.S. Patent and Trademark Offi ce. Environmental CONNECTOR DESCRIPTIONS D-Sub Positronic connectpositronic.com

WIN-D STANDARD DENSITY SEALED NEW! D-SUBMINIATURE, IMPROVED UNIBODY DESIGN The WD Unibody design provides a one piece connector body providing superior sealing performance. Solder cup, straight and right angle (90º) printed board mount terminations. Five connector variants, 9-50 contacts. Size 20 contacts, professional level performance, IP67.

WIN-DD HIGH DENSITY SEALED NEW! D-SUBMINIATURE, IMPROVED UNIBODY DESIGN The WDD Unibody design provides a one piece connector body providing superior sealing performance. Solder cup, straight and right angle (90º) printed board mount terminations. Three connector variants, 15, 26 and 44 contacts, with more variants being tooled. Size 22 contacts, professional level performance, IP67.

WIN-D STANDARD DENSITY SEALED D-SUBMINIATURE, LEGACY DESIGN The WD legacy design uses high quality material and manufacturing techniques to provide sealing. Solder cup, straight and right angle (90º) printed board mount terminations. Two connector variants: 25 (male) and 50 (male) contacts. All other standard density connector variants are supplied as Unibody, see description above. Size 20 contacts, professional level performance, IP67.

WIN-DD HIGH DENSITY SEALED D-SUBMINIATURE, LEGACY DESIGN The WDD legacy design uses high quality material and manufacturing techniques to provide sealing. Solder cup, straight and right angle (90º) printed board mount terminations. Three connector variants: 44 (male), 62 and 78 contacts. All other high density connector variants are supplied as Unibody, see description above. Size 22 contacts, professional level performance, IP67.

WIN-D AND WIN-DD Pre-wireD, SEALED FREE CABLE, D-SUBMINIATURE WD and WDD series connectors can be supplied pre-wired to provide a sealed, free cable connector option. Ten connector variants - standard density 9, 15, 25, 37, and 50; high density 15, 26, 44, 62 and 78. Can be used as a cable to cable or cable to fixed connector system.

ENVIRO-D, STANDARD DENSITY SEALED, CABLE CONNECTOR, REMOVABLE CRIMP CONTACTS, D-SUBMINIATURE The EVD series utilizes rear connector grommets to provide a sealed connector for use with removable crimp contacts. Five connector variants, 9 through 50. Size 20 contacts; standard and thermocouple crimp contacts. Immersion per MIL-STD 810. Performance conforms to IP67, and applicable requirements of MIL-DTL-24308 and SAE AS39029.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. i GENERAL INFORMATION

Environmental TABLE OF CONTENTS Positronic D-Sub connectpositronic.com

GENERAL INFORMATION

Ingress Protection Connection Systems 1, 2 and 3 ...... 1-5 Unibody and Legacy Design Environmental Sealing Features ...... 6 Connector Sealing Plate ...... 7 Information Relative to Coupling of WD, WDD and EVD Series Connectors...... 8

WD UNIBODY WD SERIES - IMPROVED UNIBODY DESIGN Technical Characteristics...... 9-10 Contact Variants...... 11 Code 2 Solder Cup...... 11 Code 3 Straight Printed Board Mount Terminations ...... NEW!...... 11 Code 5 Right Angle (90°) Printed Board Mount Termination...... 12 Right Angle (90°) and Straight Printed Board Mount Contact Hole Pattern...... 12 Ordering Information...... 13

WDD SERIES - IMPROVED UNIBODY DESIGN WDD UNIBODY Technical Characteristics...... 14-15 Contact Variants...... 16 Code 2 Solder Cup...... 16 Code 3 Straight Printed Board Mount Terminations ...... 16 NEW! Code 4 Right Angle (90°) Printed Board Mount Termination...... 17 Right Angle (90°) and Straight Printed Board Mount Contact Hole Pattern ...... 17 Ordering Information...... 18

WD SERIES

Technical Characteristics...... 19-20

WD SERIES Contact Variants...... 21 Code 2 Solder Cup ...... 21 Code 3 Straight Printed Board Mount Terminations ...... 21 Code 5 Right Angle (90°) Printed Board Mount Termination...... 22 Right Angle (90°) and Straight Printed Board Mount Contact Hole Pattern ...... 22 Ordering Information...... 23

WDD SERIES Technical Characteristics...... 24-25 Contact Variants...... 26

WDD SERIES Code 2 Solder Cup...... 26 Code 3 Straight Printed Board Mount Terminations ...... 26 Code 4 Right Angle (90°) Printed Board Mount Termination...... 27 Right Angle (90°) and Straight Printed Board Mount Contact Hole Pattern ...... 27 Ordering Information...... 28

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ii ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental TABLE OF CONTENTS D-Sub Positronic connectpositronic.com

PRE-WIRED WD/WDD SERIES Technical Characteristics...... 29-30 PRE-WIRED WD/WDD Standard Density Contact Variants; Code 22 Solder Cup Termination Free Connector with Flying Leads and Code 23 Solder Cup Termination Panel Mounted Connector with Flying Leads ...... 31 High Density Contact Variants; Code 22 Solder Cup Termination Free Connector with Flying NEW! Leads and Code 23 Solder Cup Termination Panel Mounted Connector with Flying Leads...... 32 Ordering Information...... 33 Special Options - Ordering Information ...... 34

EVD SERIES Technical Characteristics...... 35-36 Contact Variants...... 36 EVD SERIES Standard Shell Assembly ...... 37 EVD Series Design Environmental Sealing Features ...... 38 Sealing Plug ...... 38 Interfacial Seals and Rear Grommets...... 38 Removable Crimp Contacts...... 39-40 Contact Reels For Automatic Pneumatic Crimp Tools...... 40 Ordering Information...... 41 ACCESSORIES

Cul-de-sac Mounting Accessories...... 42 Enclosure Wall Mount Sealing Plate...... 42

Interfacial Seal...... 42 ACCESSORIES Composite Hoods...... NEW! ...... 43 Molded Cable Assembly...... 43 Enclosure Wall Cutout...... 44 Protective Cover...... 44

UNIQUE FEATURES Introduction...... 45 Other Sealed D-subminiature Connectors Options...... 45 Machined Aluminum Mounting Plate with Conductive O-ring...... NEW! ...... 46 Outside Wall Enclosure Mount...... 46 Lightweight Aluminum Hood...... 46 Other Environmental Connector Offerings...... 47 UNIQUE FEATURES

APPLICATION TOOLS

Introduction...... 47 Application Tool Cross Reference List...... NEW!...... 48

APPENDIX Explanation of Ingress Protection (IP) System for Enclosures...... 49 Description of NEMA Enclosure Types...... 50 Comparison between NEMA Enclosure Type Numbers and IEC Enclosure Classification Designations. . . 51

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. iii APPLICATION TOOLS POSITRONIC CABLIZED CONNECTORS

SAVE TIME AND MONEY! Let Positronic support you by cablizing your WD / WDD / EVD connector selection. Cable Assembly Design Support We work closely with customers to: 1. Design assemblies in accordance with ­customer specifications. 2. Prepare cablized connector­ ­configuration and performance specifications.­ 3. Design each system in accordance with applicable­ customer,­ domestic, Technical Sales Support and international standards. 4. Define and conduct performance and verification­ testing.

Engineering Support

Puerto Rico Cable Assembly

FOR MORE DETAILS CONTACT TECHNICAL SALES OR VISIT OUR WEB SITE AT: connectpositronic.com/cable-assemblies Quality Assurance

DIMENSIONS ARE IN INCHES [MILLIMETERS]. iv ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental GENERAL INFORMATION D-Sub Positronic connectpositronic.com

INGRESS PROTECTION CONNECTION SYSTEMS GENERAL INFORMATION

Electronic equipment is frequently used for outdoor or SYSTEM 3 is a cable to cable connection system other applications requiring environmental protection. designed for continuous electrical operation while To answer industry’s demand for affordable connection subjected to varying environmental conditions. systems compatible with environmental protection to IEC 60529 and NEMA 250-1991 performance An explanation of the dust and water ingress requirements for electrical enclosures, Positronic has protection requirements as defined by IEC 60529 introduced three dust and water ingress protection Degrees of Protection Provided by Enclosures, and connection systems. NEMA 250-1991 Enclosures for Electrical Equipment, may be found in the Appendix section of this catalog. SYSTEM 1 is an enclosure mounted connector (See section beginning on page 49) assembly. The connection system is designed for periodic electrical operation after being exposed to a It is recommended that readers familiarize variety of environmental conditions. themselves with the technical information and ingress protection rating systems contained in the SYSTEM 2 is an enclosure mounted connector Appendix so that a better understanding of dust and assembly, which is coupled to a compatible free cable water ingress protection connection systems can be connector. The connection system is designed for achieved. continuous electrical operation while being subjected to varying environmental conditions.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 1 GENERAL INFORMATION

Environmental GENERAL INFORMATION Positronic D-Sub connectpositronic.com

CONNECTION SYSTEM 1 FIXED ENCLOSURE MOUNTED CONNECTOR Provides ingress protection in an unmated condition.

*1 Panel mount sealing plate, inside wall enclosure mounting O-ring This type of ingress protection Enclosure, IEC or can be achieved by selecting: NEMA Type WD Series (page 13) OR Fixed Jackscrews Printed Board WDD Series (page 18)

Note:

*1  Outside enclosure wall panel mount Typical part number: sealing plate also available. See WD15P5C7AT7U Unique Features section, page 46.

Interfacial Seal Protective Cover

SYSTEM 1 System 1 consists of an input/output connector “Corrosion Protection” option is standard. When mechanically mounted and sealed to an enclosure. The “Corrosion Resistance” is a requirement, the connector connector and enclosure together provide a degree of is equipped with stainless steel shells and jackscrews, and protection from dust and moisture in accordance with IEC or contacts plated 0.000030 inch [0.76 µ] gold over nickel. NEMA ingress protection requirements. The enclosure and connector may be exposed to dust, splashing water, rain, or limited water immersion during its use.

CONNECTOR/ENCLOSURE ENVIRONMENTAL RATINGS

IEC 60529 Classification NEMA Enclosure Types Designations Rated to Approximate Equivalents of IP67 Degree of Protection IP67 Degree of Protection (See Appendix for detail) (See Appendix page 49 for details)

IP67, “Corrosion Protected” NEMA Types 3, 3R, 4 and 6 Dust tight and limited effects of water immersion, 0.5 meters for 30 minutes. Corrosion protected with zinc plated chromate sealed shells and jackscrews. Contacts plated gold flash over nickel.

IP67, “Corrosion Resistance” NEMA Type 4X Dust tight and limited effects of water immersion 0.5 meters for 30 minutes. Corrosion resistant with stainless steel shells and jackscrews. Contacts plated 0.000030 inch [0.76 µ] gold over nickel.

For information regarding IEC 60529 and NEMA 250-1991, see Appendix, page 49.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 2 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental GENERAL INFORMATION D-Sub Positronic connectpositronic.com

CONNECTION SYSTEM 2 FIXED ENCLOSURE MOUNTED CONNECTOR MATED TO FREE CABLE CONNECTOR Provides ingress protection of connector system for continuous electrical operation. GENERAL INFORMATION

*1* PanelPanel mountmount ssealingealing plateplate,, inside Insidewall enclosurewall mount mounting enclosure mounting

O-Ring

Enclosure, IEC or NEMA Type

Fixed Jackscrews

Printed Board

(1) Typical part number: WD15P5C7AT7U

Protective Cover

Solder contacts soldered to wire Interfacial Seal and encapsulated in epoxy resin Composite Hood Protective Cover

This type of ingress protection can be achieved by selecting: (1) Fixed WD (page 13) OR WDD series (page 18) Rotating Jackscrews (2) Typical part number: Mated to either: WD15F220Z00 (2) Free cable pre-wired WD/WDD (page 33) OR Protective Cover (3) Free cable EVD series (page 41) Crimp contacts crimped to wire and installed through rear grommet Composite Hood

Note:

*1  Outside enclosure wall panel mount sealing plate also available. See (3) Typical part number: Unique Features section, page 46. EVD15S10Z00

Rotating Jackscrews

SYSTEM 2

System 2 consists of a fixed input/output connector and a the fixed connector. This requirement enables System 2 to compatible free cable connector. The system is normally in provide the desired “Corrosion Resistance” or “Corrosion operation and may be exposed to dust, splashing water, rain, Protection” and maintain the degree of ingress protection limited water immersion or hose directed water. IP67 as specified in IEC 60529. The fixed connector is selected from the connectors offered The male connector of System 2 is always equipped with in System 1. The mating (free or cable) connector must be an interfacial seal. electrically, mechanically, and chemically compatible with

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 3 GENERAL INFORMATION

Environmental GENERAL INFORMATION Positronic D-Sub connectpositronic.com

CONNECTION SYSTEM 3 FREE CABLE-TO-CABLE Pre-wireD CONNECTORS Provides ingress protection of connector system for continuous electrical operation.

Composite Hood

Interfacial Seal

Typical Part Number: WD15P220Z400 Protective Cover

Solder contacts soldered to wire and encapsulated in epoxy resin Fixed Jackscrews Composite Hood

Protective Cover Typical part number: WD15F220Z00

This type of ingress protection Rotating Jackscrews can be achieved by selecting: Free cable pre-wired WD/WDD (page 33)

Note: Shell sizes 3, 4 & 5 only: heat shrink is provided in cable clamp area over wiring bundle.

SYSTEM 3

System 3 is a cable-to-cable interconnection system enables System 3 to provide the desired level of “Corrosion consisting of two free cable connectors. The system is Resistance” or “Corrosion Protection” and maintain the normally in operation and may be exposed to dust, splashing degree of ingress protection IP67 as specified in IEC 60529. water, rain, limited water immersion or hose directed water. The male connector of System 3 is always equipped with The connectors must be electrically, mechanically, and an interfacial seal. chemically compatible with each other. This requirement

For information regarding IEC 60529 and NEMA 250-1991, see Appendix, page 49.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 4 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental GENERAL INFORMATION D-Sub Positronic connectpositronic.com

CONNECTION SYSTEM 3 FREE CABLE-TO-CABLE CONNECTORS WITH CRIMP REMOVABLE CONTACTS

Provides ingress protection of connector system for continuous electrical operation. GENERAL INFORMATION

Composite Hood

Interfacial Seal

Typical part number: EVD15P10Z400 Protective Cover

Crimp contacts crimped to wire and installed through rear grommet Fixed Jackscrews Composite Hood

Protective Cover

Rotating Jackscrews

This type of ingress protection Typical part number: can be achieved by selecting: EVD15S10Z00 Free cable EVD series (page 41)

SYSTEM 3

System 3 is a cable-to-cable interconnection system enables System 3 to provide the desired level of “Corrosion consisting of two free cable connectors. The system is Resistance” or “Corrosion Protection” and maintain the normally in operation and may be exposed to dust, splashing degree of ingress protection IP67 as specified in IEC 60529. water, rain, limited water immersion or hose directed water. The male connector of System 3 is always equipped with The connectors must be electrically, mechanically, and an interfacial seal. chemically compatible with each other. This requirement

For information regarding IEC 60529 and NEMA 250-1991, see Appendix, page 49.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 5 GENERAL INFORMATION

Environmental GENERAL INFORMATION Positronic D-Sub connectpositronic.com

NEW! WD SERIES UNIBODY DESIGN ENVIRONMENTAL SEALING FEATURES Panel mount Panel mount sealing plate sealing plate Interfacial seal Contacts have special Contacts have special water-tight interference water-tight interference Female contact fit seal into connector insert fit seal into connetor insert

Male contact Front shell Front shell

O-ring seal O-ring seal

Shell size 3, FEATURES: 4 and 5 male • Popular, economical option for applications requiring connectors contain a sealed connectors. Stainless steel • One piece Unibody connector insert eliminates need support strip for secondary sealing processes. • Improved temperature range, increased performance, and lower cost.

WD SERIES LEGACY DESIGN ENVIRONMENTAL SEALING FEATURES

ENCLOSURE MOUNTED CONNECTORS SYSTEMS 1 AND 2

Panel mount Panel mount sealing plate sealing plate Silicone sealant Silicone sealant Contacts have special Contacts have special Female contact water-tight interference Interfacial seal water-tight interference fit seal into connector insert fit seal into connector insert

Male contact Rear shell Front shell Rear shell Front shell

Epoxy sealant O-ring seal O-ring seal Epoxy sealant

PRE-WIRED CABLE CONNECTORS SYSTEMS 2 AND 3

0.375 [9.53] max. for 0.375 0.375 0.375 [9.53] max. for shell sizes 1, 2, 3 and 4 [9.53] Silicone sealant Silicone sealant [9.53] shell sizes 1, 2, 3 and 4 0.487 [12.37] max. max. max. 0.487 [12.37] max. Female contact for shell size 5 Interfacial seal for shell size 5

Male contact Front shell Epoxy sealed 20 AWG Front shell Epoxy sealed 20 AWG [0.5 mm2 ] x 20 inch [0.5 mm2 ] x 20 inch [51 cm] flying leads [51 cm] flying leads Rear shell Rear shell

Information regarding the SEALING DESIGN FEATURES of the EVD series on page 38.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 6 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental GENERAL INFORMATION D-Sub Positronic connectpositronic.com

CONNECTOR SEALING PLATE

4-40 UNC threads GENERAL INFORMATION

C ±0.030 [±0.76]

B A±0.030 [±0.76]

CONNECTOR VARIANT SHELL A B C SIZE WD SERIES WDD SERIES STANDARD DENSITY HIGH DENSITY

1.550 0.984 0.830 1 9 15 [39.37] [24.99] [21.08]

1.878 1.312 0.830 2 15 26 [47.70] [33.32] [21.08]

2.418 1.852 0.830 3 25 44 [61.42] [47.04] [21.08]

3.066 2.500 0.830 4 37 62 [77.88] [63.50] [21.08]

2.972 2.406 0.941 5 50 78 [75.49] [61.11] [23.90]

6 -- 104 Contact Technical Sales For Availability

Connectors Designed To Customer Specifications Positronic’s WD / WDD / EVD connectors can be modified to customers specifications.

Examples: select loading of contacts for cost savings or to gain creepage and clearance distances; longer printed circuit board terminations; customer specified hardware. Contact Technical Sales with your particular requirements.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 7 GENERAL INFORMATION

Environmental GENERAL INFORMATION Positronic D-Sub connectpositronic.com

INFORMATION RELATIVE TO COUPLING OF WD, WDD AND EVD SERIES CONNECTORS RECOMMENDED COUPLING DIMENSION TO ENSURE WATER AND DUST INGRESS PROTECTION

G

SERIES G SHELL SIZE WD, EVD WDD MIN. MAX.

0.230 0.260 1 9 15 [5.84] [6.60]

0.230 0.260 2 15 26 [5.84] [6.60]

0.221 0.251 3 25 44 [5.61] [6.38]

0.221 0.251 4 37 62 Jackscrew systems [5.61] [6.38] not shown for clarity 0.080 [2.0] Max. Enclosure wall 0.221 0.251 5 50 78 [5.61] [6.38] shown for reference Composite hood not shown.

WD25P5C7AT7S WDD15F220Z40

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 8 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WD UNIBODY SERIES Environmental NEW! IMPROVED UNIBODY DESIGN PROFESSIONAL QUALITY D-Sub Positronic STANDARD DENSITY FIXED CONTACTS connectpositronic.com

NEW!

3 Popular, economical option for applications requiring sealed connectors.

One piece Unibody connector insert eliminates 3 need for secondary sealing processes. See page 6 for details. WD UNIBODY

Improved temperature range, increased 3 performance, and lower cost. 3 Fixed, size 20 contacts Terminations include solder cup, straight and 3 right angle (90°) printed board mount. See pre-wired ordering information (page 33) for free/cable connectors. 3 Five connector variants with Connectors Conforms to: 3 9, 15, 25, 37, and 50. • IP 67 per IEC 60529 • IEC 60807-2, Performance Level 2 3 Corrosion protected and • UL File # E49351 corrosion resistant options. • CSA File # LR 54219

A wide variety of options Telecommunication: 3 and accessories. • UL File # E140980

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL CHARACTERISTICS: ENVIRONMENTAL TEST SPECIFICATIONS: WIN-D series connectors mounted on IEC 60529 or NEMA Applicable IEC Moisture Tests: 250-1991 enclosures. IP65 IEC 60529 Test 14.2.5: Spray nozzle 6.3 mm diameter, delivery rate 12.5 liters per minute, 1 minute WIN-D Connector Panel mount sealing plates, when mounted on the walls of enclosures, maintain the dust and water ingress protection duration of connector exposure to spray. rating of IEC 60529 or NEMA 250 enclosure on which they are mounted. When conducting this test on Portable WIN-D connector enclosure assemblies provide dust and water ingress Enclosure Connectors, the protective protection to IP67. Refer to Appendix A for details of IP 67 ratings cover must be securely fastened over the and NEMA enclosure types 6 and 4X, as well as other IEC and NEMA face of the connector. Requirements: enclosures having less stringent environmental requirements. No water to have penetrated enclosure through connector. continued on next page. . . . DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 9 WD UNIBODY SERIES NEW! IMPROVED UNIBODY DESIGN Environmental PROFESSIONAL QUALITY Positronic D-Sub connectpositronic.com STANDARD DENSITY FIXED CONTACTS

TECHNICAL CHARACTERISTICS, continued continued from previous page. . . . IP67 IEC 60529, Test 14.2.7: Temporary immersion, 1.0 meter for MECHANICAL CHARACTERISTICS: 30 minutes. Requirements: No water to have penetrated enclosure through Size 20 Fixed Contacts: Male contact - 0.040 inch [1.02 mm] connector. mating diameter. Female contact – rugged open entry design. Applicable IEC Connector Tests After Contact Retention in

WD UNIBODY Moisture Conditioning Has Been Performed: Insulator: 6 lbs. [27N] IEC 60512-2, Test 3a: Insulation Resistance Contact Terminations: Solder cup contacts – 0.042 inch [1.06 IEC 60512-2, Test 4a: Voltage proof mm] minimum hole diameter for 20 Requirements: Portable enclosure. 1 G ohm minimum AWG [0.5 mm2 insulation resistance after connector ] wire maximum. face and contacts are dried. Voltage Straight printed board mount – 0.028 proof 1,000 V rms. inch [0.71 mm] termination diameter. • It is recommended that connectors be tested in the specific Right angle (90°) printed board mount application. – 0.028 inch [0.71 mm] termination • Service life of connectors cannot be predicted for all applications. diameter for all printed board contact MATERIALS AND FINISHES: footprints. Coding (keying): Trapezoidally shaped shells. Connector Insert: Nylon resin, UL 94V-0 black color. Enclosure Mounting Contacts: Precision machined copper alloy. Accessories: Cul-de-sac blind hole fasteners, angle Contact Plating:  brackets and push-on fasteners. Corrosion Protection: Gold flash over nickel plate. Inside Wall Corrosion Resistant: Gold plate 0.000030 inch [0.76 µ] over Minimum thickness 0.040 inch [1.02 nickel plate. Enclosure Mount: mm]. Maximum thickness 0.080 inch Shells, Jackscrew Systems and [2.03 mm]. Cul-de-sac Mounting Accessories: Locking Systems: Jackscrews. Corrosion Protection: Steel, zinc plated with chromate seal. Mechanical Operations: 500 operations minimum per IEC 60512-5. Corrosion Resistant: Stainless steel passivated. Push-on Fasteners: Phosphor bronze with tin plate. Required Sealing 1.75 in-lb. [0.20 Nm] minimum. Angle Brackets: Brass, zinc plate with chromate seal. Plate Mounting Torque: 2.25 in-lb. [0.25 Nm] maximum. Interfacial Seal: Thermoplastic Elastomer (TPE), SantopreneTM or equivalent. ELECTRICAL CHARACTERISTICS: Panel Mount Sealing Plate Assembly: Glass filled thermoplastic with Contact Current Rating: 7.5 amperes nominal, elastomer O-ring. Shell size 3, 4, and 5 Initial Contact Resistance: 0.008 ohms maximum. male connectors contain stainless steel Insulator Resistance: 5 G ohms. support strip. Clearance and Creepage Protective Cover Over Conductive polyethylene or conductive Distance Minimum: 0.039 inch [1.0mm]. Connector Shell: polyester. Proof Voltage: 1000 V r.m.s. Working Voltage: 300 V r.m.s. CLIMATIC CHARACTERISTICS: Temperature Range: -40°C to +125°C

Visit our web site for the latest catalog updates and supplements at www.connectpositronic.com/connector-details/d-subminiature/environmentally-sealed/catalog

Do you need 2-D drawings or 3-D models? Once you have made a connector selection, contact Techni- cal Sales if you would like a 2-D drawing or 3-D model. If we do not have your specific part number on file, we can create one for you. Or, please visit www.connectpositronic.com and use the search function.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 10 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WD UNIBODY SERIES Environmental NEW! IMPROVED UNIBODY DESIGN PROFESSIONAL QUALITY D-Sub Positronic STANDARD DENSITY FIXED CONTACTS connectpositronic.com

CONTACT VARIANTS * FACE VIEW OF MALE OR REAR VIEW OF FEMALE

1 32 4 5 1 2 3 654 87 21 43 5 76 1098 131211

6 87 9 9 01 11 21 13 41 51 14 51 61 17 18 19 02 12 22 32 42 52 WD 9 WD 15 WD 25 Available with male and female contacts Available with male and female contacts Currently available with female contacts. For male contact variants, see page 21.

21 43 5 76 1098 131211 161514 17 1 2 3 4 65 87 1211109 13 14 171615 1918 18 19 20 21 242322 25 2726 28 29 30 3231 33

20 21 22 2423 25 26 27 28 29 30 31 32 33 34 35 36 37 34 35 3736 38 39 40 41 42 43 44 45 46 47 48 49 50 WD 37 WD 50 Available with male and female contacts Currently available with female contacts. For male contact variants, see page 21.

* If a variant is not listed above, consult Technical Sales, as Positronic is ready to support requirements for WD UNIBODY other D-subminiature variants and is tooling additional variants. For information on existing design variants, see page 21. For sealing plate dimensions see page 7.

SOLDER CUP TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 2 0.177 [4.50] 0.150 [3.81] 0.080 [2.03] max. panel thickness

Fixed female jackscrews 20 AWG max. 2 [0.5 mm ] OUTSIDE WALL ENCLOSURE MOUNT Not available in Unibody design. O-ring seal See Unique Feature section, page 46. 0.135 [3.43]

0.257 [6.53] Enclosure shown for reference only Typical part number: INSIDE WALL WD15F2C5AT7U ENCLOSURE MOUNT

STRAIGHT SOLDER PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 3, 0.150 [3.81] CONTACT EXTENSION

Swaged spacer with Fixed female jackscrews push-on fastener, phoshpor bronze Enclosure shown for reference only OUTSIDE WALL O-ring seal ENCLOSURE MOUNT Not available in Unibody design. See Unique Feature O-ring section, page 46. 0.080 [2.03] max. panel thickness 0.150 [3.81]

0.177 [4.50] Typical part number: 0.010 [0.25] WD15F3C8AT7U 0.130 nominal 0.150 Ø0.028 [0.71] typ. INSIDE WALL [3.30] ENCLOSURE MOUNT [3.81] DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 11 WD UNIBODY SERIES NEW! IMPROVED UNIBODY DESIGN Environmental PROFESSIONAL QUALITY Positronic D-Sub connectpositronic.com STANDARD DENSITY FIXED CONTACTS

RIGHT ANGLE (90°) PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE MOUNT SEALING PLATE CODE 5, 0.188 [4.78] CONTACT EXTENSION

INSIDE WALL ENCLOSURE MOUNT WD**5***U 0.188 [4.78] CONTACT EXTENSION

PART NUMBER ABCD

WD UNIBODY 1.204 0.984 0.244 0.188 WD9*5***U [30.58] [24.99] [6.20] [4.78] Fixed female A 1.532 1.312 0.244 0.188 jackscrews WD15*5***U B [38.91] [33.32] [6.20] [4.78] ±0.008 2.072 1.852 0.244 0.188 [±0.20] WD25F5***U [52.63] [47.04] [6.20] [4.78] 2.720 2.500 0.244 0.188 WD37*5***U [69.09] [63.50] [6.20] [4.78] 2.626 2.406 0.300 0.188 WD50F5***U C [66.70] [61.11] [7.62] [4.78] 0.177 [4.50] 0.177 [4.50] D D Numbering shown is rear 0.112 [2.84] view of male and face view 0.112 [2.84] Typ. of female connector Typ. 0.112 [2.84] Enclosure shown Cul-de-sac style Typ. Enclosure shown for reference only threaded rivet 12345678 for reference only

15 14 13 12 11 10 9

O-ring seal O-ring seal 0.160 [4.06] Ø0.028 [0.71] Typ. Nominal 0.080 [2.03] max. Push-on fastener, 0.080 [2.03] max. panel thickness beryllium copper panel thickness 0.150 [3.81] 0.150 [3.81] Typical Part Number: Typical Part Number: WD15P5C7AT7U WD50F5C7AT7U

RIGHT ANGLE (90°) AND STRAIGHT PRINTED BOARD CONTACT HOLE PATTERN Mount connector with mating face positioned to follow direction of arrows.

Sym. Sym. Sym. 0.492 0.656 0.216 [5.49] 0.378 [9.60] 0.926 [23.52] 0.652 [16.56] [12.50] [16.66] 0.108 [2.74] 0.054 [1.37] 0.109 [2.77] Typ. Typ. Typ.

0.112 0.055 [1.40] 0.112 0.054 [1.37] 0.112 [2.84] 0.108 [2.74] Typ. [2.84] Typ. [2.84] 0.162 [4.11] Typ. 0.324 [8.23] 0.598 [15.19] WD 9 WD 15 WD 25 Sym. Sym. 1.203 0.870 1.250 [31.75] 0.978 [24.84] [30.56] [22.10] 0.109 0.109 [2.77] [2.77] 0.224 SUGGESTED Typ. Typ. [5.69] PRINTED BOARD HOLE SIZES: Suggest 0.123 ±0.003 [3.12] Ø holes for mounting connector 0.112 0.112 with push-on fasteners. 0.055 [1.40] [2.84] 0.055 [1.40] Typ. Typ. [2.84] 0.924 [23.47] Suggest 0.045 [1.14] Ø hole for 0.815 [20.70] contact termination positions. WD 37 WD 50 DIMENSIONS ARE IN INCHES [MILLIMETERS]. 12 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WD UNIBODY SERIES Environmental NEW! IMPROVED UNIBODY DESIGN PROFESSIONAL QUALITY D-Sub Positronic STANDARD DENSITY FIXED CONTACTS connectpositronic.com

ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 8

† Unibody is the preferred design. If a variant is not listed in Step 2, consult Technical Sales, as Positronic is ready to support requirements for other D-subminiature variants and is tooling additional variants. For information on existing design variants, see page 21.

STEP 1 2 3 4 5 6 7 8 9 10

EXAMPLE WD 9 F 2 C5 A T7 SU /AA

STEP 1 - Basic Series STEP 10 - SPECIAL OPTIONS WD - WD Unibody series CONTACT TECHNICAL SALES

FOR SPECIAL OPTIONS WD UNIBODY † STEP 2 - C onnector Variants 9 - Male and Female STEP 9 - E nvironmental 15 - Male and Female Compliance † 25 - Female only options 37 - Male and Female /AA -  Compliant per EU Directive † 50 - Female only 2002/95/EC (RoHS)

STEP 3 - Connector Gender Note: If compliance to environmental ­legislation is not required, this step will not P - Male with interfacial seal be used. Example: WD9F2C5AT7SU F – Female NEW! STEP 8 - Shells And Accessory Options *2 STEP 4 - Contact Termination Type U - Corrosion Protected Unibody Design 2 - Solder cup Steel shells and jackscrews zinc plated with 3 - Solder, straight printed board mount with 0.150 [3.81] chromate seal. Contacts gold flash over tail length. nickel plate. 5 - Solder, right angle (90°) printed board mount, contact extension 0.188 [4.78]. SU- Corrosion Resistant Unibody Design Stainless steel shells and jackscrews Contacts 0.000030 inch [0.76µ] gold plated *1 STEP 5 - CUL-DE-SAC Style Mounting over nickel. Accessories C5 - Inside wall mounting for Code 2 and 3 (step 4) only. 1 C7 - Inside wall mounting for Code 5 (step 4), right angle (90°) * STEP 7 - Female Fixed Jackscrews printed board mount only. Consists of an assembly of angle T7 - Always used when ordering C5, C7 and C8 (Step 5). bracket, alignment bar and push-on fastener. C8 - Inside wall mounting for Code 3 (step 4) only. Includes push-on fastener. *1 STEP 6 - E nclosure Wall Mount NOTE: For C9 outside wall mounting option, refer to Unique Sealing Plate Features section, page 46. A - Inside wall enclosure mounted connector.

NOTE: *1 For additional information listed in Steps 5, 6, and 7, see the Accessories section, page 42. *2 See pre-wired ordering information, page 33, for free/cable connectors.

Do you need 2-D drawings or 3-D models? See page 10 for more information

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 13 WDD UNIBODY SERIES NEW! IMPROVED UNIBODY DESIGN Environmental PROFESSIONAL QUALITY Positronic D-Sub connectpositronic.com HIGH DENSITY FIXED CONTACTS

NEW!

3 Popular, economical, high density option for applications 3 requiring sealed connectors. 3 One piece Unibody connector insert eliminates need for 3 secondary sealing processes. See page 6 for details. 3 Improved temperature range, increased 3 performance, and lower cost. 3 Fixed, size 22 contacts WDD UNIBODY 3 Terminations include solder cup, straight and right angle (90°) printed board mount. See pre-wired ordering information (page 33) for free/cable connectors. 3 Three connector variants include 15, 26 and 44, with more being tooled. Connectors Conforms to: See WDD section (page 26) for all other high density sizes. • IP 67 per IEC 60529 • UL File # E49351 3 Corrosion protected and • CSA File # LR 54219 corrosion resistant options. Telecommunication: 3 A wide variety of options • UL File # E140980 and accessories.

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL CHARACTERISTICS: ENVIRONMENTAL TEST SPECIFICATIONS:

WIN-DD series connectors mounted on IEC 60529 or NEMA Applicable IEC Moisture Tests: 250-1991 enclosures. IP65 IEC 60529 Test 14.2.5: Spray nozzle 6.3 mm diameter, delivery WIN-DD connector panel mount sealing plates, when mounted rate 12.5 liters per minute, 1 minute on the walls of enclosures, maintain the dust and water ingress duration of connector exposure to spray. protection rating of IEC 60529 or NEMA 250 enclosure on which they When conducting this test on Portable are mounted. WIN-DD connector enclosure assemblies provide dust Enclosure Connectors, the protective and water ingress protection to IP67. Refer to Appendix A for detail cover must be securely fastened over the of IP 67 ratings and NEMA enclosure types 6 and 4X, as well as other face of the connector. Requirements: enclosures having less stringent environmental requirements. No water to have penetrated enclosure through connector. continued on next page. . . .

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 14 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WDD UNIBODY SERIES Environmental NEW! IMPROVED UNIBODY DESIGN PROFESSIONAL QUALITY D-Sub Positronic HIGH DENSITY FIXED CONTACTS connectpositronic.com

TECHNICAL CHARACTERISTICS, continued continued from previous page. . . .

IP67 IEC 60529 Test 14.2.7: Temporary immersion, 1.0 meter for MECHANICAL CHARACTERISTICS: 30 minutes. Requirements: No water to have penetrated enclosure through Size 22 Fixed Contacts: Male contact - 0.030 inch [0.75 mm] connector. mating diameter. Female contact – rugged open entry design. Applicable IEC Connector Tests After Moisture Contact Retention in Conditioning Has Been Performed: Connector insert: 6 lbs. [27N] IEC 60512-2, Test 3a: Insulation Resistance Contact Terminations: Solder cup contacts – 0.035 inch [0.89 IEC 60512-2, Test 4a: Voltage proof mm] minimum hole diameter for 22 AWG Requirements: Portable enclosure. 1 G ohm minimum [0.3 mm2] wire maximum. insulation resistance after connector Straight printed board mount – 0.020 face and contacts are dried. Voltage inch [0.51 mm] termination diameter. proof 1,000 V rms. • It is recommended that connectors be tested in the specific Right angle (90°) printed board mount application. contact terminations 0.030 inch [0.76 • Service life of connectors cannot be predicted for all applications. mm] termination diameter. Coding (keying): Trapezoidally shaped shells. MATERIALS AND FINISHES: Enclosure Mounting Accessories: Cul-de-sac blind hole fasteners, angle Connector Insert: Nylon resin, UL 94V-0 black color. brackets and push-on fasteners. Contacts: Precision machined copper alloy Inside Wall Contact Plating: Enclosure Mount: Minimum thickness 0.040 inch [1.02 Corrosion Protection: Gold flash over nickel plate. mm]. Maximum thickness 0.080 inch Corrosion Resistant: Gold plate 0.000030 inch [0.76 µ] over [2.03 mm]. nickel plate. Locking Systems: Jackscrews. Mechanical Operations: 500 operations minimum per IEC 60512-5. Shell, Jackscrew Systems and Required Sealing 1.75 in-lb. [0.20 Nm] minimum. Cul-de-sac Mounting Accessories: Corrosion Protection: Steel, zinc plated with chromate seal. Plate Mounting Torque: 2.25 in-lb. [0.25 Nm] maximum. Corrosion Resistant: Stainless steel passivated. WDD UNIBODY Push-on Fasteners: Phosphor bronze with tin plate. ELECTRICAL CHARACTERISTICS: Angle Brackets: Brass, zinc plate with chromate seal. Contact Current Rating: 5 amperes nominal Initial Contact Resistance: 0.010 ohms maximum. Interfacial Seal: Thermoplastic Elastomer (TPE), Insulator Resistance: 5 G ohms. SantopreneTM or equivalent. Clearance and Creepage Panel Mount Sealing Distance Minimum: 0.039 inch [1.0mm]. Plate Assembly: Glass filled thermoplastic with elastomer Proof Voltage: 1000 V r.m.s. O-ring. Working Voltage: 300 V r.m.s. Protective Cover Over Connector Shell: Conductive polyethylene or conductive CLIMATIC CHARACTERISTICS: polyester. Temperature Range: -40°C to +125°C

Visit our web site for the latest catalog updates and supplements at www.connectpositronic.com/connector-details/d-subminiature/environmentally-sealed/catalog

Do you need 2-D drawings or 3-D models? Once you have made a connector selection, contact Techni- cal Sales if you would like a 2-D drawing or 3-D model. If we do not have your specific part number on file, we can create one for you. Or, please visit www.connectpositronic.com and use the search function.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 15 WDD UNIBODY SERIES NEW! IMPROVED UNIBODY DESIGN Environmental PROFESSIONAL QUALITY Positronic D-Sub connectpositronic.com HIGH DENSITY FIXED CONTACTS

CONTACT VARIANTS * FACE VIEW OF MALE OR REAR VIEW OF FEMALE

1 5 1 9 1 10 16 15 6 10 18 30 31 11 15 19 26 44 WDD 15 WDD 26 WDD 44 Available with male and female contacts Available with male and female contacts Currently available with female contacts. For male contact variants, see page 26.

* If a variant is not listed above, consult Technical Sales, as Positronic is ready to support requirements for other D-subminiature variants and is tooling additional variants. For information on existing design variants, see page 26. For sealing plate dimensions see page 7.

SOLDER CUP TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 2

0.177 [4.50] 0.150 [3.81] 0.080 [2.03] max. panel thickness

WDD UNIBODY Fixed female jackscrews 22 AWG max. OUTSIDE WALL [0.3 mm2 ] ENCLOSURE MOUNT Not available in Unibody design. See Unique Feature O-ring seal section, page 46.

0.085 [2.16] 0.145 [3.68] Typical part number: 0.267 [6.78] Enclosure shown WDD26P2C5AT7U for reference only INSIDE WALL ENCLOSURE MOUNT

STRAIGHT SOLDER PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 3, 0.150 [3.81] CONTACT EXTENSION

Swaged spacer with Fixed female jackscrews push-on fastener, phoshpor bronze Enclosure shown for reference only OUTSIDE WALL O-ring seal ENCLOSURE MOUNT Not available in Unibody design. See Unique Feature Typical part number: section, page 46. 0.080 [2.03] max. WDD26P3C8AT7U panel thickness 0.150 [3.81] O-ring 0.177 [4.50]

INSIDE WALL ENCLOSURE MOUNT 0.010 [0.25] 0.130 nominal 0.150 Ø0.020 [0.51] typ. [3.81] [3.30]

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 16 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WDD UNIBODY SERIES Environmental NEW! IMPROVED UNIBODY DESIGN PROFESSIONAL QUALITY D-Sub Positronic HIGH DENSITY FIXED CONTACTS connectpositronic.com

RIGHT ANGLE (90°) PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE MOUNT SEALING PLATE INSIDE WALL CODE 4, 0.219 [5.56] CONTACT EXTENSION ENCLOSURE MOUNT

WDD26*4**** 0.219 [5.56] CONTACT EXTENSION

PART NUMBER ABCD Fixed female A jackscrews 1.204 0.984 0.319 0.219 B WDD15*4**** [30.58] [24.99] [8.10] [5.56] ±0.008 [±0.20] 1.532 1.312 0.319 0.219 WDD26*4**** [38.91] [33.32] [8.10] [5.56]

2.072 1.852 0.319 0.219 WDD44F4**** [52.63] [47.04] [8.10] [5.56]

C

0.177 [4.50] D 0.100 [2.54] Typ. Numbering shown is rear view of male and face view 0.100 [2.54] Typ. of female connector

Enclosure shown Cul-de-sac style for reference only threaded rivet 9 8 7 6 5 4 3 2 1 Typical part number: 17 17 16 15 14 13 12 11 10 WDD26P4C7AT7U

O-ring seal 0.125 [3.18] Ø0.030 [0.76] Typ. 0.080 [2.03] max. Nominal Push-on fastener, panel thickness 0.150 [3.81] beryllium copper

RIGHT ANGLE (90°) AND STRAIGHT PRINTED BOARD CONTACT HOLE PATTERN WDD UNIBODY MOUNT CONNECTOR WITH MATING FACE POSITIONED TO FOLLOW DIRECTION OF ARROWS.

WDD15 MALE WDD15 FEMALE 0.984 [24.99] 0.984 [24.99]

0.492 [12.50] 0.190 [4.83] 0.492 [12.50] 0.215 [5.46]

A A

0.090 [2.29] Typ. A 0.090 [2.29] Typ. A C C WDD26 MALE WDD26 FEMALE 1.312 [33.32] 1.312 [33.32]

0.656 [16.66] 0.380 [9.65] 0.656 [16.66] 0.385 [9.78] A A

A A 0.090 [2.29] Typ. C 0.090 [2.29] Typ. C WDD44 FEMALE

CODE 1.852 [47.04] NUMBER A C 0.926 [23.52] 0.655 [16.64] 0.078 0.035 3 [1.98] [0.89] A

0.100 0.045 4 [2.54] [1.14] 0.090 [2.29] Typ. A C SUGGESTED PRINTED BOARD HOLE SIZES: Suggest 0.123 ±0.003 [3.12] Ø holes for mounting connector with push-on fasteners DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 17 WDD UNIBODY SERIES NEW! IMPROVED UNIBODY DESIGN Environmental PROFESSIONAL QUALITY Positronic D-Sub connectpositronic.com HIGH DENSITY FIXED CONTACTS

ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 8

† Unibody is the preferred design. If a variant is not listed in Step 2, consult Technical Sales, as Positronic is ready to support requirements for other D-subminiature variants and is tooling additional variants. For information on existing design variants, see page 26.

STEP 1 2 3 4 5 6 7 8 9 10 EXAMPLE WDD 26 F 2 C5 A T7 SU /AA

STEP 1 - Basic Series STEP 10 - SPECIAL OPTIONS WDD - WDD Unibody series CONTACT TECHNICAL SALES FOR SPECIAL OPTIONS † STEP 2 - C onnector Variants 15 - Male and Female 26 - Male and Female STEP 9 - E nvironmental † 44 - Female only Compliance options STEP 3 - Connector Gender /AA -  Compliant per EU Directive WDD UNIBODY 2002/95/EC (RoHS) P - Male with interfacial seal F - Female Note: If compliance to environmental

2 ­legislation is not required, this step will not * STEP 4 - Contact Termination Type be used. Example: WDD26F2C5AT7SU 2 - Solder cup. 3 - Solder, straight printed board mount with 0.150 [3.81] NEW! tail length. STEP 8 - Shells And Accessory Options 4 - Solder, right angle (90°) printed board mount, contact U - Corrosion Protected Unibody Design extension 0.219 [5.56]. Steel shells and jackscrews zinc plated with chromate seal. Contacts gold flash over nickel plate. *1 STEP 5 - CUL-DE-SAC Style Mounting Accessories SU - Corrosion Resistant Unibody Design Stainless steel shells and jackscrews C5 - Inside wall mounting for Code 2 and 3 (step 4) only. Contacts 0.000030 inch [0.76 µ] gold plated C7 - Inside wall mounting for Code 4 (step 4), right angle (90°) over nickel. printed board mount only. Consists of an assembly of angle bracket, alignment bar and push-on fastener. C8 - Inside wall mounting for Code 3 (step 4) only. Includes *1 STEP 7 - Female Fixed Jackscrews push-on fastener. T7 - Always used when ordering C5, C7 and C8 (step 5).

NOTE: For C9 outside wall mounting option, refer to Unique Features section, page 46.

*1 STEP 6 - E nclosure Wall Mount NOTE: Sealing Plate *1 For additional information listed in Steps 5, 6, and 7, see the A - Inside wall enclosure mounted connector. Accessories section, page 42. *2 See pre-wired section, page 33, for free/cable connectors.

Do you need 2-D drawings or 3-D models? See page 10 for more information

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 18 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WD SERIES Environmental PROFESSIONAL QUALITY D-Sub STANDARD DENSITY FIXED CONTACTS Positronic connectpositronic.com

3 Popular, economical option for applications 3 requiring sealed connectors. 3 Precision sealing process ensures environmental performance. See page 6 for details. 3 Fixed, size 20 contacts 3 Terminations include solder cup, straight and 3 right angle (90°) printed board mount. See pre-wired ordering information (page 33) for free/cable connectors. 3 Five connector variants with 9, 15, 25, 37, and 50 contacts. Connectors Conforms to: See WD Unibody section (page 11) for • IP 67 per IEC 60529 variants supplied in Unibody design. • IEC 60807-2, performance level 2 3 Corrosion protected and • UL File # E49351 3 corrosion resistant options. • CSA File # LR 54219 Telecommunication: 3 A wide variety of options • UL File # E140980 3 and accessories.

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL CHARACTERISTICS: ENVIRONMENTAL TEST SPECIFICATIONS WD SERIES WIN-D series connectors mounted on IEC 60529 or NEMA 250-1991 Applicable IEC Moisture Tests enclosures for electrical equipment. IP65 IEC 60529 Test 14.2.5 Spray nozzle 6.3 mm diameter, delivery WIN-D connector panel mount sealing plates, when mounted on rate 12.5 liters per minute, 1 minute the walls of enclosures, maintain the dust and water ingress protection duration of connector exposure to rating of IEC 60529 or NEMA 250 enclosure on which they are mounted. spray. When conducting this test WIN-D connector enclosure assemblies provide dust and water ingress on System 1 – Portable Enclosure protection to IP67 which allows temporary immersion in water to a Connectors, the protective cover must depth of 0.5 meters for 30 minutes without ingress of water or dust be securely fastened over the face of to the enclosure. Refer to Appendix A for details of IP67 ratings and the connector. Requirements: No water NEMA enclosure types 6 and 4X, as well as other IEC and NEMA to have penetrated enclosure through enclosures having less stringent environmental requirements. connector. WIN-D series cable connector with cable support WIN-D cable IP67 IEC 60529 Test 14.2.7 Temporary immersion, 0.5 meters for connectors meet all the requirement of IEC 60807-2 Performance Level 30 minutes. Requirements: No water 2, plus the ingress protection requirement of IP67 thereby maintaining to have penetrated enclosure through the electrical integrity and the ingress protection level of the connection connector. system. continued on next page. . . . DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 19 WD SERIES Environmental PROFESSIONAL QUALITY Positronic STANDARD DENSITY FIXED CONTACTS D-Sub connectpositronic.com

TECHNICAL CHARACTERISTICS . . . . continued from previous page. MECHANICAL CHARACTERISTICS: Applicable IEC Connector Tests After Moisture Size 20 Fixed Contacts: Male contact – 0.040 inch [1.02 mm] Exposure Tests Have Been Performed mating diameter. Female contact - IEC 60512-2, Test 3a: Insulation Resistance rugged open entry design. IEC 60512-2, Test 4a: Voltage proof Contact Retention in Requirements: Connector insert: 6 lbs. [27N] System 1 – Portable enclosure. 1 G ohm minimum Resistance to Solder insulation resistance after connector Iron Heat: 500°F (260°C) for 10 seconds duration face and contacts are dried. Voltage per IEC 60512-6. proof 1,000 V rms. Contact Terminations: Solder cup contacts – 0.042 inch [1.06 System 2 – Enclosure mounted connector to cable mm] minimum hole diameter for 20 connector. 1 G ohm minimum insulation AWG [0.5 mm2] wire maximum. resistance. 1,000 V rms. Voltage proof.  Straight printed board mount – 0.028 System 3 – Cable to cable connection systems. inch [0.71 mm] termination diameter. 1 G ohm minimum insulation resistance. Right angle (90°) printed board mount – 1,000 V rms. Voltage proof. 0.028 inch [0.71 mm] termination diameter • It is recommended that connectors be tested in the specific for all printed board contact footprints. application. Coding (keying): Trapezoidally shaped shells. • Service life of connectors cannot be predicted for all applications. Enclosure Mounting Cul-de-sac blind hole fasteners, angle Accessories: brackets and push-on fasteners. MATERIALS AND FINISHES: Inside Wall Minimum thickness 0.040 inch [1.0 Connector Insert: Nylon resin, UL 94V-0 black color. Enclosure Mount: mm]. Maximum thickness 0.080 inch Contacts: Precision machined copper alloy. [2.0 mm]. Contact Plating:  Locking Systems: Jackscrews. Corrosion Protection: Gold flash over nickel plate. Mechanical Operations: 250 operations minimum per IEC Corrosion Resistant: Gold plate 0.000030 inch [0.76 µ] over 60512-5 IP67 immersion rated. nickel plate.  500 operations minimum per IEC Shells, Jackscrew Systems and 60512-5 IP65 spray nozzle rated. Cul-de-sac Mounting Accessories: Required Sealing 1.75 in-lb. [0.20 Nm] minimum. Steel, zinc plated with chromate seal. Corrosion Protection: Plate Mounting Torque: 2.25 in-lb. [0.25 Nm] maximum. Corrosion Resistant: Stainless steel passivated. Push-on Fasteners: Phosphor bronze with tin plate. ELECTRICAL CHARACTERISTICS: Angle Brackets: Brass, zinc plate with chromate seal. 7.5 amperes nominal. Hoods (Cable supports): Composite. Contact Current Rating: 0.008 ohms maximum. Interfacial Seal: Thermoplastic Elastomer (TPE), Initial Contact Resistance: Insulator Resistance: 5 G ohms. SantopreneTM or equivalent. Panel Mount Sealing Clearance and Creepage 0.039 inch [1.0mm]. Plate Assembly: Glass filled thermoplastic with elastomer Distance Minimum: O-ring. Proof Voltage: 1000 V r.m.s. 300 V r.m.s. Protective Cover Over Working Voltage: WD SERIES Connector Shell: Conductive polyethylene or conductive CLIMATIC CHARACTERISTICS: polyester. Temperature Range: -25°C to +85°C

Visit our web site for the latest catalog updates and supplements at www.connectpositronic.com/connector-details/d-subminiature/environmentally-sealed/catalog

Do you need 2-D drawings or 3-D models? Once you have made a connector selection, contact Techni- cal Sales if you would like a 2-D drawing or 3-D model. If we do not have your specific part number on file, we can create one for you. Or, please visit www.connectpositronic.com and use the search function.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 20 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WD SERIES Environmental PROFESSIONAL QUALITY D-Sub STANDARD DENSITY FIXED CONTACTS Positronic connectpositronic.com

CONTACT VARIANTS * FACE VIEW OF MALE

21 43 5 76 1098 131211 161514 17 21 43 5 76 1098 131211 18 19 20 21 242322 25 2726 28 29 30 3231 33

14 51 61 17 18 19 02 12 22 32 42 52 34 35 3736 38 39 40 41 42 43 44 45 46 47 48 49 50 WD 25 * WD 50 * Currently available with male contacts Currently available with male contacts

* Contact variants for size 9, 15, 37, 25 (female) and 50 (female) are available in the IMPROVED Unibody Design. See page 11 for details. For sealing plate dimensions see page 7.

SOLDER CUP TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE 0.177 [4.50] CODE 2 0.150 [3.81] OUTSIDE WALL 0.080 [2.03] max. ENCLOSURE MOUNT panel thickness

Fixed female jackscrews 20 AWG max. [0.5 mm2 ] Enclosure shown for reference only

O-ring seal O-ring seal

0.135 [3.43] Typical part number: 0.257 [6.53] Enclosure shown for reference only WD9P2C5AT70 0.150 [3.81] INSIDE WALL For more information, see Unique ENCLOSURE MOUNT Features section, page 46.

STRAIGHT SOLDER PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 3, 0.150 [3.81] CONTACT EXTENSION

INSIDE WALL OUTSIDE WALL ENCLOSURE MOUNT ENCLOSURE MOUNT WD SERIES Swaged spacer with Fixed female jackscrews push-on fastener, Enclosure shown phoshpor bronze Enclosure shown for reference only for reference only

O-ring seal O-ring seal

0.080 [2.03] max. 0.150 [3.81] panel thickness O-ring 0.150 [3.81] For more information, see Unique 0.177 [4.50] Features section, page 46.

0.010 [0.25] Typical part number: 0.130 nominal 0.150 Ø0.028 [0.71] typ. [3.30] WD15P3C8AT70 [3.81] DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 21 WD SERIES Environmental PROFESSIONAL QUALITY Positronic STANDARD DENSITY FIXED CONTACTS D-Sub connectpositronic.com

Right Angle (90°) PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE MOUNT SEALING PLATE CODE 5, 0.188 [4.78] CONTACT EXTENSION INSIDE WALL ENCLOSURE MOUNT

WD**5**** 0.188 [4.78] CONTACT EXTENSION

PART NUMBER ABCD Fixed female A jackscrews 2.072 1.852 0.244 0.188 B WD25P5**** [52.63] [47.04] [6.20] [4.78] ±0.008 [±0.20] 2.626 2.406 0.300 0.188 WD50P5**** [66.70] [61.11] [7.62] [4.78]

C 0.177 [4.50] 0.177 [4.50] D D Numbering shown is rear 0.112 [2.84] view of male and face view 0.112 [2.84] Typ. of female connector Typ. 0.112 [2.84] Enclosure shown Cul-de-sac style Typ. Enclosure shown for reference only threaded rivet 12345678 for reference only

15 14 13 12 11 10 9

O-ring seal O-ring seal 0.160 [4.06] Ø0.028 [0.71] Typ. Nominal 0.080 [2.03] max. Push-on fastener, 0.080 [2.03] max. panel thickness beryllium copper panel thickness 0.150 [3.81] 0.150 [3.81]

Typical part number: Typical part number: WD25P5C7AT70 WD50P5C7AT70

Right Angle (90°) AND STRAIGHT PRINTED BOARD CONTACT HOLE PATTERN

WD SERIES Mount connector with mating face positioned to follow direction of the arrow.

Sym. 1.203 0.870 Sym. [30.56] [22.10] 0.926 [23.52] 0.652 [16.56] 0.109 0.109 [2.77] [2.77] 0.224 Typ. Typ. [5.69]

0.055 [1.40] 0.112 Typ. [2.84] 0.055 [1.40] 0.112 0.598 [15.19] Typ. [2.84] 0.815 [20.70] WD 25 WD 50

SUGGESTED PRINTED BOARD HOLE SIZES: Suggest 0.123 ±0.003 [3.12] Ø holes for mounting connector with push-on fasteners. Suggest 0.045 [1.14] hole for contact termination positions.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 22 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WD SERIES Environmental PROFESSIONAL QUALITY D-Sub STANDARD DENSITY FIXED CONTACTS Positronic connectpositronic.com

ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 8

† Contact variants for size 9, 15, 37, 25 (female) and 50 (female) have been transitioned to the preferred Unibody design. For WD Unibody Ordering Information, see page 13.

STEP 1 2 3 4 5 6 7 8 9 10

EXAMPLE WD 25 P 2 C5 A T7 S /AA

STEP 1 - Basic Series STEP 10 - SPECIAL OPTIONS WD Series CONTACT TECHNICAL SALES FOR SPECIAL OPTIONS † STEP 2 - C onnector Variants

† 25 - Male only. STEP 9 - E nvironmental † 50 - Male only. Compliance options STEP 3 - Connector Gender /AA -  Compliant per EU Directive 2002/95/EC (RoHS) P - Male with interfacial seal F - Female Note: If compliance to environmental ­legislation is not required, this step will not STEP 4 - Contact Termination Type be used. Example: WD25P2C5AT7S 2 - Solder cup. 3 - Solder, straight printed board mount with 0.150 [3.81] STEP 8 - Shells And Accessory Options tail length. 0 - Corrosion Protected 5 - Solder, right angle (90°) printed board mount, contact Steel shells and jackscrews zinc plated with extension 0.188 [4.78]. chromate seal. Contacts gold flash over nickel plate.

STEP 5 - CUL-DE-SAC Style Mounting S - Corrosion Resistant Accessories Stainless steel shells and jackscrews Contacts 0.000030 inch [0.76µ] gold plated C5 - Inside wall mounting for Code 2 and 3 (step 4) only. over nickel. Available for sizes: 25 male, and 50 male. C7 - Inside wall mounting for Code 5 (step 4), right angle (90°) printed board mount only. Consists of an assembly of angle STEP 7 - Female Fixed Jackscrews bracket, alignment bar and push-on fastener. T7 - Always used when ordering C5, C7 and C8 (step 5). Available for sizes: 25 male, and 50 male. C8 - Inside wall mounting for Code 3 (step 4) only. Includes WD SERIES push-on fastener. Available for sizes: 25 male, and 50 male. STEP 6 - E nclosure Wall Mount Sealing Plate NOTE: For C9 outside wall mounting option, refer to Unique A - Inside wall enclosure mounted connector. Features section, page 46.

Do you need 2-D drawings or 3-D models? See page 10 for more information

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 23 WDD SERIES Environmental PROFESSIONAL QUALITY Positronic HIGH DENSITY FIXED CONTACTS D-Sub connectpositronic.com

3Popular, economical, high density option for applications requiring sealed connectors. 3Precision sealing process ensures environmental performance. See page 6 for details. 3Fixed, size 22 contacts 3Terminations include solder cup, straight and right angle (90°) printed board mount. See pre-wired ordering information (page 33) for free/cable connectors. 3Five connector variants with 15, 26, 44, 62, and 78 contacts. See WDD Unibody section (page 16) for variants supplied in Unibody design. Connectors Conforms to: 3Corrosion protected and corrosion • IP 67 per IEC 60529 resistant options. • UL File # E49351 • CSA File # LR 54219 3A wide variety of options and accessories. Telecommunication: • UL File # E140980

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL CHARACTERISTICS: ENVIRONMENTAL TEST SPECIFICATIONS WIN-DD series connectors mounted on IEC 60529 or NEMA 250 Applicable IEC Moisture Tests enclosures for electrical equipment. IP65 IEC 60529 Test 14.2.5: Spray nozzle 6.3 mm diameter, delivery WIN-DD connector panel mount sealing plates, when mounted on rate 12.5 liters per minute, 1 minute the walls of enclosures, maintain the dust and water ingress protection duration of connector exposure to rating of IEC 60529 or NEMA 250 enclosures on which they are spray. When conducting this test mounted. WIN-DD connector-enclosure assemblies provide dust and on System 1 – Portable Enclosure water ingress protection to IP67 which allows temporary immersion in Connectors, the protective cover must water to a depth of 0.5 meters for 30 minutes without ingress of water be securely fastened over the face of or dust to the enclosure. Refer to Appendix A for details of IP67 ratings the connector. Requirements: No water

WDD SERIES and NEMA enclosure types 6 and 4X, as well as other enclosures to have penetrated enclosure through having less stringent environmental requirements. connector. WIN-DD series cable connectors with cable support WIN-DD cable IP67 IEC 60529 Test 14.2.7: Temporary immersion, 0.5 meters for connectors meet the requirements of IEC 60807-2 Performance Level 30 minutes. Requirements: No water 2, where applicable, plus the ingress protection requirements of IP67 to have penetrated enclosure through thereby maintaining the electrical integrity and the ingress protection connector. level of the connection system. continued on next page. . . .

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 24 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WDD SERIES Environmental PROFESSIONAL QUALITY D-Sub HIGH DENSITY FIXED CONTACTS Positronic connectpositronic.com

TECHNICAL CHARACTERISTICS, continued continued from previous page. . . .

Applicable IEC Connector Tests After Moisture MECHANICAL CHARACTERISTICS: Exposure Tests Have Been Performed Size 22 Fixed Contacts: Male contact – 0.030 inch [0.75 mm] IEC 60512-2, Test 3a: Insulation Resistance mating diameter. Female contacts - IEC 60512-2, Test 4a: Voltage proof rugged “Robi-D” open entry design. Requirements: Closed entry design available, contact System 1 – Portable enclosure. 1 G ohm minimum insulation technical sales. resistance after connector face and contacts are dried. Contact Retention in Voltage proof 1,000 V rms. Insulator: 9 lbs. [40N] System 2 – Enclosure mounted connector to cable connector. 1 Resistance to Solder G ohm minimum insulation resistance. 1,000 V rms. Iron Heat: 500°F [260°C] for 10 seconds duration Voltage proof. per IEC 60512-6. System 3 – Cable to cable connection systems. 1 G ohm minimum Contact Terminations: Solder cup contacts – 0.035 inch [0.89 insulation resistance. 1,000 V rms. Voltage proof. mm] minimum hole diameter for 22 AWG • It is recommended that connectors be tested in the specific [0.3 mm2] wire maximum. application. • Service life of connectors cannot be predicted for all applications. Straight printed board mount – 0.020 inch [0.5 mm] termination diameter. MATERIALS AND FINISHES: Right angle (90°) printed board mount - 0.030 inch [0.76 mm] termination diameter. Connector insert: Glass filled polyester per ASTM D5927 , UL 94V-0, black color. Coding (keying): Trapezoidally shaped shells. Contacts: Precision machined copper alloy. Enclosure Mounting Cul-de-sac blind hole fasteners, angle Contact Plating: Accessories: brackets and push-on fasteners. Corrosion Protection: Gold flash over nickel plate. Inside Wall Minimum thickness 0.040 inch [1.0 mm]. Corrosion Resistant: Gold plate 0.000030 inch [0.76 µ] over Enclosure Mount: Maximum thickness 0.080 inch [2.0 mm]. nickel plate. Locking Systems: Jackscrews. Shells, Jackscrew Systems and Mechanical Operations: 250 operations minimum per IEC 60512- Cul-de-sac Mounting Accessories: 5 IP67 immersion rated. Corrosion Protection: Steel, zinc plated with chromate seal. 500 operations minimum per IEC 60512- Corrosion Resistant: Stainless steel passivated. 5 IP65 spray nozzle rated. Push-on Fasteners: Phosphor bronze with tin plate. Required Sealing 1.75 in-lb. [0.20 Nm] minimum. Angle Brackets: Brass, zinc plate with chromate seal. Plate Mounting Torque: 2.25 in-lb. [0.25 Nm] maximum. Hoods (Cable supports): Composite. ELECTRICAL CHARACTERISTICS: Interfacial Seal: Thermoplastic Elastomer (TPE), Contact Current Rating: 5 amperes nominal. SantopreneTM or equivalent. Initial Contact Resistance: 0.010 ohms maximum. Panel Mount Sealing Insulator Resistance: 5 G ohms. Plate Assembly: Glass filled thermoplastic with elastomer O-ring. Clearance and Creepage Distance (minimum): 0.042 inch [1.06 mm]. Protective Cover Over Proof Voltage: 1000 V r.m.s. Connector Shell: Conductive polyethylene or conductive 300 V r.m.s. polyester. Working Voltage: CLIMATIC CHARACTERISTICS: Temperature Range: -25°C to +85°C

Visit our web site for the latest catalog updates and supplements at www.connectpositronic.com/connector-details/d-subminiature/environmentally-sealed/catalog

Do you need 2-D drawings or 3-D models? Once you have made a connector selection, contact Techni- cal Sales if you would like a 2-D drawing or 3-D model. If we do not have your specific part number on file, we can create one for you. Or, please visit www.connectpositronic.com and use the search function. WDD SERIES

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 25 WDD SERIES Environmental PROFESSIONAL QUALITY Positronic HIGH DENSITY FIXED CONTACTS D-Sub connectpositronic.com

CONTACT VARIANTS* FACE VIEW OF MALE OR REAR VIEW OF FEMALE

1 20 1 1 21 39 16 15 22 21 40 59 30 42 31 43 60 78 44 62 WDD 44 WDD 62 WDD 78 Currently available with male contacts. Currently available with male and female contacts. Currently available with male and female contacts. For female contact variants, see page 16.

* Contact variants for size 15, 26 and 44 (female) are available in the IMPROVED Unibody design. See page 16 for details. For sealing plate dimensions see page 7.

SOLDER CUP TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 2 0.177 [4.50] OUTSIDE WALL 0.150 [3.81] 0.080 [2.03] max. ENCLOSURE MOUNT panel thickness

Fixed female jackscrews 22 AWG max. [0.3 mm2 ] Enclosure shown for reference only

O-ring seal O-ring seal

0.085 [2.16] 0.145 [3.68] 0.267 [6.78] Enclosure shown Typical part number: for reference only WDD62F2C5AT70 0.150 [3.81]

INSIDE WALL For more information, see Unique ENCLOSURE MOUNT Features section, page 46.

STRAIGHT SOLDER PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE WALL MOUNT SEALING PLATE CODE 3, 0.150 [3.81] CONTACT EXTENSION INSIDE WALL ENCLOSURE MOUNT OUTSIDE WALL ENCLOSURE MOUNT

Swaged spacer with Fixed female jackscrews push-on fastener, Enclosure shown Enclosure shown phoshpor bronze for reference only for reference only

O-ring seal O-ring seal

0.080 [2.03] max. 0.150 [3.81] panel thickness O-ring WDD SERIES 0.150 [3.81] For more information, see Unique Features section, page 46. 0.177 [4.50]

Typical part number: 0.010 [0.25] 0.130 WDD62F3C8AT70 nominal 0.150 Ø0.020 [0.51] typ. [3.81] [3.30]

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 26 ALL DIMENSIONS ARE SUBJECT TO CHANGE. WDD SERIES Environmental PROFESSIONAL QUALITY D-Sub HIGH DENSITY FIXED CONTACTS Positronic connectpositronic.com

Right Angle (90°) PRINTED BOARD MOUNT TERMINATION WITH ENCLOSURE MOUNT SEALING PLATE CODE 4, 0.219 [5.56] CONTACT EXTENSION

WDD**4**** 0.219 [5.56] CONTACT EXTENSION

Fixed female A jackscrews PART B NUMBER ABCD ±0.008 [±0.20] 2.072 1.852 0.319 0.219 WDD44M4**** [52.63] [47.04] [8.10] [5.56]

2.720 2.500 0.319 0.219 WDD62*4**** [69.09] [63.50] [8.10] [5.56]

C 2.626 2.406 0.319 0.219 WDD78*4**** [66.70] [61.11] [8.10] [5.56] 0.177 [4.50] 0.177 [4.50] D D 0.100 [2.54] Typ. Numbering shown is rear 0.100 [2.54] Typ. view of male and face view 0.100 [2.54] Typ. of female connector 0.100 [2.54] Typ. Enclosure shown Cul-de-sac style 0.100 [2.54] Typ. Enclosure shown for reference only threaded rivet 9 8 7 6 5 4 3 2 1 for reference only 17 17 16 15 14 13 12 11 10

O-ring seal O-ring seal 0.125 [3.18] Ø0.030 [0.76] Typ. Nominal 0.080 [2.03] max. Push-on fastener, 0.080 [2.03] max. panel thickness beryllium copper panel thickness 0.150 [3.81] 0.150 [3.81] Typical part number: INSIDE WALL WDD62P4C7AT70 Typical part number: ENCLOSURE MOUNT WDD78P4C7AT70

Right Angle (90°) AND STRAIGHT PRINTED BOARD CONTACT HOLE PATTERN Mount connector with mating face positioned to follow direction of arrows. WDD44 MALE 1.852 [47.04]

0.926 [23.52] 0.650 [16.51] CODE ABCD A NUMBER 3 0.078 [1.98] 0.082 [2.08] 0.035 [0.89] 0.123 [3.12]

4 0.100 [2.54] 0.100 [2.54] 0.045 [1.14] 0.100 [2.54] 0.090 [2.29] Typ. A C WDD62 MALE WDD62 FEMALE 2.500 [63.50] 2.500 [63.50]

1.250 [31.75] 0.973 [24.71] 1.250 [31.75] 0.975 [24.77]

A A

A A C C 0.095 [2.41] Typ. 0.095 [2.41] Typ. WDD78 MALE WDD78 FEMALE 2.406 [61.11] 2.406 [61.11]

1.203 [30.56] 0.903 [22.94] 1.203 [30.56] 0.903 [22.94] B B B B

D B D B C C WDD SERIES 0.095 [2.41] Typ. 0.095 [2.41] Typ. DIMENSIONS ARE IN INCHES [MILLIMETERS]. SUGGESTED PRINTED BOARD HOLE SIZES: ALL DIMENSIONS ARE SUBJECT TO CHANGE. 27 Suggest 0.123 ±0.003 [3.12] Ø holes for mounting connector with push-on fasteners WDD SERIES Environmental PROFESSIONAL QUALITY Positronic HIGH DENSITY FIXED CONTACTS D-Sub connectpositronic.com

ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 8

† Contact variants for size 15, 26 and 44 (female) have been transitioned to the preferred Unibody design. For WDD Unibody Ordering Information, see page 18

STEP 1 2 3 4 5 6 7 8 9 10

EXAMPLE WDD 62 F 2 C5 A T7 S /AA

STEP 1 - Basic Series STEP 10 - SPECIAL OPTIONS WDD series CONTACT TECHNICAL SALES FOR SPECIAL OPTIONS † STEP 2 - C onnector Variants † 44 - Male only. STEP 9 - E nvironmental 62 - Male and Female Compliance 78 - Male and Female options /AA -  Compliant per EU Directive 2002/95/EC (RoHS) STEP 3 - Connector Gender P - Male with interfacial seal Note: If compliance to environmental F - Female ­legislation is not required, this step will not be used. Example: WDD62F2C5AT7S STEP 4 - Contact Termination Type 2 - Solder cup STEP 8 - Shells And Accessory Options 3 - Solder, straight printed board mount with 0.150 [3.81] 0 - Corrosion Protected tail length. Steel shells and jackscrews zinc plated with 4 - Solder, right angle (90°) printed board mount, contact chromate seal. Contacts gold flash over nickel plate. extension 0.219 [5.56]. S - Corrosion Resistant Stainless steel shells and jackscrews STEP 5 - CUL-DE-SAC Style Mounting Contacts 0.000030 inch [0.76 µ] gold plated Accessories over nickel. C5 - Inside wall mounting for Code 2 and 3 (step 4) only. Available for sizes: 62 and 78. STEP 7 - Female Fixed Jackscrews C7 - Inside wall mounting for Code 4 (step 4), right angle (90°) printed board mount only. Consists of an assembly of angle T7 - Always used when ordering C5, C7 and C8 (step 5). bracket, alignment bar and push-on fastener. Available for sizes: 62 and 78. C8 - Inside wall mounting for Code 3 (step 4) only. Includes STEP 6 - E nclosure Wall Mount Sealing push-on fastener. Available for sizes: 62 and 78. Plate A - Inside wall enclosure mounted connector. NOTE: For C9 outside wall mounting option, refer to Unique Features section, page 46. WDD SERIES Do you need 2-D drawings or 3-D models? See page 10 for more information

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 28 ALL DIMENSIONS ARE SUBJECT TO CHANGE. PRE-WIRED WD / WDD SERIES Environmental PROFESSIONAL QUALITY NEW! SEALED FREE CABLE CONNECTOR D-Sub Positronic STANDARD OR HIGH DENSITY connectpositronic.com PRE-WIRED WD/WDD

3 Popular, economical option for applications requiring sealed connectors.

Precision sealing process ensures 3 environmental performance. See page 6 for details.

Pre-wired, size 20 and size 22 contacts Connectors Conforms to: 3 • IP 67 per IEC 60529 Ten connector variants include • IEC 60807-2, performance level 2 3 9, 15, 25, 37, and 50 (standard density); • UL File # E49351 15, 26, 44, 62, and 78 (high density) • CSA File #LR 54219 contacts. Telecommunication: Corrosion protected and corrosion • UL File # E140980 3 resistant options.

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL CHARACTERISTICS: ENVIRONMENTAL TEST SPECIFICATIONS WIN-D and WIN-DD series connectors mounted on IEC 60529 or Applicable IEC Moisture Tests NEMA 250 enclosures for electrical equipment. IP65 IEC 60529 Test 14.2.5: Spray nozzle 6.3 mm diameter, delivery WIN-D and WIN-DD connector panel mount sealing plates, when rate 12.5 liters per minute, 1 minute mounted on the walls of enclosures, maintain the dust and water duration of connector exposure to spray. ingress protection rating of IEC 60529 or NEMA 250 enclosures on When conducting this test on System which they are mounted. WIN-DD connector-enclosure assemblies 1 – Portable Enclosure Connectors, provide dust and water ingress protection to IP67 which allows the protective cover must be securely temporary immersion in water to a depth of 0.5 meters for 30 minutes fastened over the face of the connector. without ingress of water or dust to the enclosure. Refer to Appendix A Requirements: No water to have for details of IP67 ratings and NEMA enclosure types 6 and 4X, as well penetrated enclosure through connector. as other enclosures having less stringent environmental requirements. IP67 IEC 60529 Test 14.2.7: Temporary immersion, 0.5 meters for 30 minutes. Requirements: No water WIN-D and WIN-DD series cable connectors with cable support to have penetrated enclosure through WIN-D and WIN-DD cable connectors meet the requirements of IEC connector. 60807-2 Performance Level 2, where applicable, plus the ingress protection requirements of IP67 thereby maintaining the electrical integrity and the ingress protection level of the connection system. continued on next page. . . .

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 29 PRE-WIRED WD/WDD PRE-WIRED WD / WDD SERIES PROFESSIONAL QUALITY Environmental NEW! SEALED FREE CABLE CONNECTOR Positronic D-Sub connectpositronic.com STANDARD OR HIGH DENSITY

TECHNICAL CHARACTERISTICS, continued continued from previous page. . . . MECHANICAL CHARACTERISTICS: Applicable IEC Connector Tests After Moisture Exposure Tests Fixed Contacts: Have Been Performed  WD Size 20: Male contact – 0.040 inch [1.02 mm] IEC 60512-2, Test 3a: Insulation Resistance mating diameter. Female contacts - IEC 60512-2, Test 4a: Voltage proof rugged open entry design. Requirements: WDD Size 22: Male contact – 0.030 inch [0.75 mm] System 1 – Portable enclosure. 1 G ohm minimum insulation mating diameter. Female contacts - resistance after connector face and contacts are dried. rugged “Robi-D” open entry design. Voltage proof 1,000 V rms. Closed entry design available, contact technical sales. Enclosure mounted connector to cable connector. System 2 – Contact Retention in 1 G ohm minimum insulation resistance. 1,000 V rms. Connector Insert: 6 lbs. [27N] Voltage proof. Resistance to Solder – Cable to cable connection systems. 1 G ohm minimum System 3 Iron Heat: 500°F [260°C] for 10 seconds duration insulation resistance. 1,000 V rms. Voltage proof. per IEC 60512-6. • It is recommended that connectors be tested in the specific Contact Terminations: Solder cup contacts - soldered to wire application. with 20 in [50 cm] flying leads. • Service life of connectors cannot be predicted for all applications. Coding (keying): Trapezoidally shaped shells. Enclosure Mounting Cul-de-sac blind hole fasteners, angle MATERIALS AND FINISHES: Accessories: brackets and push-on fasteners. Connector Insert: WD: Nylon resin, UL 94V-0, black color. Inside Wall Minimum thickness 0.040 inch [1.0 mm]. WDD: Glass filled polyester per ASTM Enclosure Mount: Maximum thickness 0.080 inch [2.0 mm]. D5927 UL 94V-0, black color. Locking Systems: Jackscrews. Contacts: Precision machined copper alloy. Mechanical Operations: 250 operations minimum per IEC 60512- Contact Plating: 5 IP67 immersion rated. Corrosion Protection: Gold flash over nickel plate. 500 operations minimum per IEC 60512- Corrosion Resistant: Gold plate 0.000030 inch [0.76 µ] over 5 IP65 spray nozzle rated. nickel plate. Required Sealing 1.75 in-lb. [0.20 Nm] minimum. Shells, Jackscrew Systems and Plate Mounting Torque: 2.25 in-lb. [0.25 Nm] maximum. Cul-de-sac Mounting Accessories: Corrosion Protection : Steel, zinc plated with chromate seal. ELECTRICAL CHARACTERISTICS: Corrosion Resistant: Stainless steel passivated. Contact Current Rating: WD: 7.5 amperes nominal. Push-on Fasteners: Phosphor bronze with tin plate. WDD: 5 amperes nominal. Angle Brackets: Brass, zinc plate with chromate seal. Initial Contact WD: 0.008 ohms maximum. Hoods (Cable supports): Composite. WDD: 0.010 ohms maximum. Interfacial Seal: Thermoplastic Elastomer (TPE), Insulator Resistance: 5 G ohms. SantopreneTM or equivalent. Clearance and Creepage WD: 0.039 inch [1 mm]. Panel Mount Sealing Distance (minimum): WDD: 0.042 inch [1.06 mm]. Plate Assembly: Glass filled thermoplastic with elastomer Proof Voltage: 1000 V r.m.s. O-ring. Working Voltage: 300 V r.m.s. Protective Cover Over Connector Shell: Conductive polyethylene or conductive CLIMATIC CHARACTERISTICS: polyester. Temperature Range: -25°C to +85°C

Visit our web site for the latest catalog updates and supplements at www.connectpositronic.com/connector-details/d-subminiature/environmentally-sealed/catalog

Do you need 2-D drawings or 3-D models? Once you have made a connector selection, contact Techni- cal Sales if you would like a 2-D drawing or 3-D model. If we do not have your specific part number on file, we can create one for you. Or, please visit www.connectpositronic.com and use the search function.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 30 ALL DIMENSIONS ARE SUBJECT TO CHANGE. PRE-WIRED WD / WDD SERIES Environmental PROFESSIONAL QUALITY NEW! SEALED FREE CABLE CONNECTOR D-Sub Positronic STANDARD OR HIGH DENSITY connectpositronic.com

STANDARD DENSITY CONTACT VARIANTS FACE VIEW OF MALE OR REAR VIEW OF FEMALE PRE-WIRED WD/WDD

1 32 4 5 1 2 3 654 87 21 43 5 76 1098 131211

6 87 9 9 01 11 21 13 41 51 14 51 61 17 18 19 02 12 22 32 42 52 WD 9 WD 15 WD 25

21 43 5 76 1098 131211 161514 17 1 2 3 4 65 87 1211109 13 14 171615 1918 18 19 20 21 242322 25 2726 28 29 30 3231 33

20 21 22 2423 25 26 27 28 29 30 31 32 33 34 35 36 37 34 35 3736 38 39 40 41 42 43 44 45 46 47 48 49 50 WD 37 WD 50

SOLDER CUP TERMINATION SOLDERED TO WIRE AND ENCAPSULATED IN EPOXY RESIN 20 INCH [50 CM] FLYING LEADS FOR USE WITH WD SERIES CODE 22

20 AWG [0.5 mm 2] flying leads

20 inch [51cm] Typical part number: Note: Z hood not shown for clarity. WD15F220Z0S

SOLDER CUP TERMINATION SOLDERED TO WIRE FOR USE WITH ENCLOSURE MOUNTED CONNECTORS 20 INCH [50 CM] FLYING LEADS FOR USE WITH WD SERIES INSIDE WALL CODE 23 ENCLOSURE MOUNT 0.177 [4.50] 0.150 [3.81] OUTSIDE WALL 0.080 [2.03] max. ENCLOSURE MOUNT panel thickness

Fixed female jackscrews 20 AWG [0.5 mm 2] Enclosure shown flying leads for reference only

O-ring seal O-ring seal 20 inch [51cm]

Enclosure shown for reference only 0.150 [3.81] Typical part number: For more information, see Unique WD15F23C5AT70 Features section, page 46.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 31 PRE-WIRED WD/WDD PRE-WIRED WD / WDD SERIES PROFESSIONAL QUALITY Environmental NEW! SEALED FREE CABLE CONNECTOR Positronic D-Sub connectpositronic.com STANDARD OR HIGH DENSITY

HIGH DENSITY CONTACT VARIANTS FACE VIEW OF MALE OR REAR VIEW OF FEMALE

1 5 1 9 1 10 16 15 6 10 18 30 31 11 15 19 26 44 WDD 15 WDD 26 WDD 44

1 20 1 21 39 22 21 59 42 40 43 60 78 62 WDD 62 WDD 78

SOLDER CUP TERMINATION SOLDERED TO WIRE AND ENCAPSULATED IN EPOXY RESIN 20 INCH [50 CM] FLYING LEADS FOR USE WITH WDD SERIES CODE 22

22 AWG [0.3 mm 2] flying leads

20 inch [51cm]

Note: Z hood not shown for clarity. Typical part number: WDD15F220Z0S

SOLDER CUP TERMINATION SOLDERED TO WIRE FOR USE WITH ENCLOSURE MOUNTED CONNECTORS 20 INCH [50 CM] FLYING LEADS INSIDE WALL FOR USE WITH WDD SERIES ENCLOSURE MOUNT CODE 23

0.177 [4.50] 0.150 [3.81] OUTSIDE WALL 0.080 [2.03] max. panel thickness ENCLOSURE MOUNT

Fixed female jackscrews 22 AWG [0.3 mm 2] flying leads Enclosure shown for reference only

O-ring seal O-ring seal 20 inch [51cm]

Enclosure shown for reference only 0.150 [3.81] Typical part number: WDD15F23C5AT70 For more information, see Unique Features section, page 46.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 32 ALL DIMENSIONS ARE SUBJECT TO CHANGE. PRE-WIRED WD / WDD SERIES Environmental PROFESSIONAL QUALITY NEW! SEALED FREE CABLE CONNECTOR D-Sub Positronic STANDARD OR HIGH DENSITY connectpositronic.com

ORDERING INFORMATION - CODE NUMBERING SYSTEM

Specify Complete Connector By Selecting An Option From Step 1 Through 8 PRE-WIRED WD/WDD

STEP 1 2 3 4 5 6 7 8 9 10

EXAMPLE WDD 9 F 22 0 Z 0 S /AA

STEP 1 - Basic Series STEP 10 - SPECIAL OPTIONS WD Series - Size 20 contacts See page 34 for additional options. WDD Series - Size 22 contacts

STEP 2 - C onnector Variants STEP 9 - E nvironmental WD Series Connector Variants Compliance 9, 15, 25, 37, and 50 options /AA -  Compliant per EU Directive WDD Series Connector Variants 2002/95/EC (RoHS) 15, 26, 44, 62, and 78 Note: If compliance to environmental ­legislation is not required, this step will not STEP 3 - Connector Gender be used. Example: WDD9F220Z0S P - Male with interfacial seal F - Female STEP 8 - Shells And Accessory Options 0 - Corrosion Protected Steel shells and jackscrews zinc plated with chromate seal. Contacts gold flash over STEP 4 - Contact Termination Type nickel plate.

22 - Solder cup, soldered to wire and encapsulated in epoxy S - Corrosion Resistant resin with 20 inch [51 cm] flying leads. Other lengths Stainless steel shells and jackscrews available by special order (See page 34). Contacts 0.000030 inch [0.76µ] gold plated 23 - Solder cup, soldered to wire with 20 inch [51 cm] flying over nickel. leads. Not encapsulated. For use with enclosure mounted connectors. STEP 7 - Female Fixed Jackscrews STEP 5 - CUL-DE-SAC Style Mounting 0 - None. Use only with Code 0 (step 5). Accessories T7 - Always used when ordering C5 (step 5). 0 - No mounting plate or accessories. Available only with Code 22 (step 4). C5 - Inside wall mounting. STEP 6 - E nclosure Wall Mount Sealing NOTE: For C9 outside wall mounting option, refer to Unique Plate OR HOODS Features section, page 46. 0 - None Use only with Code 0 (step 5). A - Inside wall enclosure mounted connector. Available with C5 (step 5) only. Z - Composite hood with rotating male jackscrews. Available with Code 22 (step 4) only. Z4 - Composite hood with fixed female jackscrews. Available with Code 22 (step 4) only.

Do you need 2-D drawings or 3-D models? See page 10 for more information

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 33 PRE-WIRED WD/WDD PRE-WIRED WD / WDD SERIES PROFESSIONAL QUALITY Environmental NEW! SEALED FREE CABLE CONNECTOR Positronic D-Sub connectpositronic.com STANDARD OR HIGH DENSITY

SPECIAL OPTIONS PART NUMBER SUFFIX (STEP 10) FOR Pre-wireD CABLE ASSEMBLIES ORDERING INFORMATION- CODE NUMBERING SYSTEM Specify Special Options for Completed Connector By Selecting Options Below

STEP 10 PLATING COLOR GAUGE LENGTH TOLERANCE

EXAMPLE 14 C 24G 3.05 T20

PLATING TOLERANCE Omit if standard plating is required. Omit if standard tolerance (refer to Table 1 -14 - Contacts to be plated 0.000030 below) is required. [0.76µ] gold over nickel. TXX - XX = ± tolerance in mm. -15 - Contacts to be plated 0.000050 [1.27µ] gold over nickel. -50 - Contacts to be plated 0.000050 [1.27µ] gold over copper. LENGTH Contact technical sales for Omit if standard 20 in [0.51 mm] length is required. additional plating options. Insert length in meters (0.3048 x length in feet) to two decimal places. Use leading 0 if less than one. COLOR Omit if standard (black) is required for all wires. C - Colored wire option, consists of up to 10 different wire insulation colors pre-wired in the following configuration: GAUGE Omit if standard wire is required - Standard for WD series is 20 AWG. Contact Contact Standard for WDD series is 22 AWG. Position Insulation Position Insulation Number * Color Number * Color 22G - 22 AWG wire 24G - 24 AWG wire 1 Brown 6 Blue

2 Red 7 Violet 3 Orange 8 Gray 4 Yellow 9 White 5 Green 0 Black

* The contact position number indicated represents the last TABLE 1. CABLE LENGTH TOLERANCE digit of the contact position number. (I.E.: position 37 will be Violet) Cable Length <1 m >1 m, >8 m, > 16 m [meters] <8 m <16 m Tolerance [millimeters] ±25 ±50 ±75 ±100

STANDARD WIRE CHARACTERISTICS Materials: Wire: Stranded tinned copper 7/30-22 AWG and 7/28-20 AWG Insulation: PVC Specification: per Mil-W-16878/1-PVC Temperature Rating: -55º TO +105ºC Voltage Rating: 600 Volts

WDD15F22Z0X-1422G3.05T20

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 34 ALL DIMENSIONS ARE SUBJECT TO CHANGE. EVD SERIES Environmental MILITARY / INDUSTRIAL QUALITY FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS D-Sub Positronic STANDARD DENSITY REMOVABLE CONTACTS connectpositronic.com

3 Popular, economical option for applications requiring sealed connectors. 3 Precision sealing process, grommets, and interfacial seals ensure environmental performance. EVD SERIES See page 38 for details. 3 Materials are resistant to a wide variety of harsh liquids. 3 Crimp removable, size 20 contacts 3 Five connector variants include 9, 15, 25, 37, and 50 contacts. Connectors Conforms to: 3 Corrosion protected and corrosion • IP 67 per IEC 60529 resistant options. • Performance conforms to applicable requirements of MIL-DTL-24308 and 3 A wide variety of options SAE AS39029 and accessories.

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL CHARACTERISTICS: EVD connectors, having crimp contacts, meet all of the applicable Immersion, 2 hours at a While Immersed: requirements of MIL-DTL-24308 in addition to the requirements shown depth of 36 inch 1) Insulation resistance greater than 100 below: [914.4 mm] in mated mega ohms. Test Requirements condition per MIL-STD 810 2) Withstand a potential of 1000 VAC IP67 Temporary immersion, 0.5 meters for Method 512.3. Procedure 1. (rms) without evidence of 30 minutes. Mated condition. No water flashover or breakdown. to have penetrated enclosure through connector. MATERIALS AND FINISHES: Humidity per 1) No deterioration of performance. Connector Insert: Glass-filled DAP per ASTM-D-5948 type EIA 364-31 method IV, 2) Insulation resistance greater than 100 SDG-F, UL 94V-0, green color. Method 1002.2, Type II mega ohms. Contacts: Precision machined cooper alloy. 3) Withstand a potential of 1000 VAC Contact Plating: Military performance - 0.000050 inch (rms) without evidence of flashover or [1.27 µ] gold over nickle plate. breakdown. Industrial performance - 0.000030 inch [0.76 µ] gold over nickel. Fluid Immersion 1) No detrimental damage. per ANSI/EIA-364-10 2) Meet mating and unmating require- Shells: Steel with zinc plate with chromate seal Test Conditions A and D ments of MIL-DTL-24308. and stainless steel, passivated. DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 35 EVD SERIES MILITARY / INDUSTRIAL QUALITY Environmental FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS Positronic D-Sub connectpositronic.com STANDARD DENSITY REMOVABLE CONTACTS

TECHNICAL CHARACTERISTICS, continued continued from previous page. . . . Mounting Spacers: Steel or brass, zinc plate with chromate ELECTRICAL CHARACTERISTICS: seal. Dry Conditions, Basic Connector Body: Jackscrew Systems: Steel with zinc plate and chromate seal; and stainless steel, passivated. Contact Current Rating, Tested per UL 1977: 18 amperes, 2 contacts energized. Hoods: Composite. 14 amperes, 6 contacts energized. Grommet and Fluorosilicone Rubber per MIL- EVD SERIES 11 amperes, 15 contacts energized. Interfacial Seal: DTL-25988. 10 amperes, 25 contacts energized. Bonding Material: Fluorosilicone based sealant/adhesive. 9 amperes, 50 contacts energized. Protective Cover Over Connector Shell: Conductive polyethylene or conductive Visit http://www.connectpositronic.com/connector-details/ polyester. d-subminiature/environmentally-sealed/technical-specifications/ to view Sealing Plug: Teflon. temperature rise curves. Initial Contact Resistance: 0.004 ohms maximum. MECHANICAL CHARACTERISTICS: Proof Voltage: 1,000 V r.m.s. Size 20 Removable Contacts: Install contact to rear face of connector Insulation Resistance: 5 G ohms. insert and release from rear face of Clearance and Creepage connector insert. Male - 0.040 inch Distance (minimum): 0.039 inch [1.0 mm]. [1.02 mm] diameter. Female - PosiBand Working Voltage: 300 V r.m.s. closed entry design Contact Retention in CLIMATIC CHARACTERISTICS: Insulator: 9 lbs. [40 N]. Temperature Range: -55°C to +125°C. Contact Terminations: Closed barrel crimp, wire sizes 20 AWG [0.5 mm2] through 24 AWG [0.25 mm2]; THERMOCOUPLE CONTACTS: Solder contacts - 0.042 inch [1.06 mm] Size 20 crimp contacts are available, see page 40 for details. minimum hole diameter for 20 AWG [0.5 mm2] through 24 AWG [0.25 mm2] wire size. Coding (keying): Trapezoidally shaped shells. Locking Systems: Jackscrews. Mechanical Operations: 500 operations minimum per IEC 60512-5.

Visit our web site for the latest catalog updates and supplements at www.connectpositronic.com/connector-details/d-subminiature/environmentally-sealed/catalog

CONTACT VARIANTS FACE VIEW OF MALE OR REAR VIEW OF FEMALE

1 32 4 5 1 2 3 654 87 21 43 5 76 1098 131211

6 87 9 9 01 11 21 13 41 51 14 51 61 17 18 19 02 12 22 32 42 52 EVD 9 EVD 15 EVD 25

21 43 5 76 1098 131211 161514 17 1 2 3 4 65 87 1211109 13 14 171615 1918 18 19 20 21 242322 25 2726 28 29 30 3231 33

20 21 22 2423 25 26 27 28 29 30 31 32 33 34 35 36 37 34 35 3736 38 39 40 41 42 43 44 45 46 47 48 49 50 EVD 37 EVD 50

For information regarding REMOVABLE CONTACTS, see illustration/drawing and charts on pages 39 & 40 .

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 36 ALL DIMENSIONS ARE SUBJECT TO CHANGE. EVD SERIES Environmental MILITARY / INDUSTRIAL QUALITY FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS D-Sub Positronic STANDARD DENSITY REMOVABLE CONTACTS connectpositronic.com

STANDARD SHELL ASSEMBLY

RECOMMENDED MATING DIMENSIONS

EVD25P000E20 (upper left), EVD15P00000 (middle) and Shell Sizes 1 & 2 = EVD15P1000 (upper right). NEW! 0.265±0.015 [6.73±0.38] Shell Sizes 3, 4, 5 & 6 = 0.256±0.015 [6.50±0.38]

10º EVD SERIES B Typ. G over shell M B1 N max. over grommet K 0.050 [1.27] ±0.010 H P E D1 D over max. over shell grommet

C 0.036 [0.91] ±0.008 0.718 [18.24] max. 0.120 [3.05] ±0.005 Ø mounting hole A

OPTIONAL SHELL ASSEMBLY OPTIONAL SHELL ASSEMBLY (0) WITH UNIVERSAL FLOAT MOUNTS (F) 0.120 [3.05] ±0.010

Ø0.120±0.005 [3.05±0.13] Mounting hole, two places for 0.032 [0.81] 0.086 [2.18] +0.005-0.000 stainless steel shell (0 option) Total diametral float Mounting hole, two places

A B B1 C D D1 E G H K M CONNECTOR GENDER ±0.015 ±0.005 ±0.005 ±0.005 ±0.005 ±0.005 ±0.015 ±0.010 ±0.010 ±0.005 ±0.010 VARIANT SIZES [0.38] [0.13] [0.13] [0.13] [0.13] [0.13] [0.38] [0.25] [0.25] [0.13] [0.25] 1.213 0.666 0.984 0.329 0.494 0.759 0.422 0.233 0.422 MALE EVD 9 [30.81] [16.92] [24.99] [8.36] [12.55] [19.28] [10.72] [5.92] [10.72] (SHELL SIZE 1) 1.213 0.643 0.984 0.311 0.494 0.759 0.422 0.243 0.429 FEMALE [30.81] [16.33] [24.99] [7.90] [12.55] [19.28] [10.72] [6.17] [10.90] 1.541 0.994 1.312 0.329 0.494 1.083 0.422 0.233 0.422 MALE EVD 15 [39.14] [25.25] [33.32] [8.36] [12.55] [27.51] [10.72] [5.92] [10.72] (SHELL SIZE 2) 1.541 0.971 1.312 0.311 0.494 1.083 0.422 0.243 0.429 FEMALE [39.14] [24.66] [33.32] [7.90] [12.55] [27.51] [10.72] [6.17] [10.90] 2.088 1.534 1.852 0.329 0.494 1.625 0.422 0.230 0.426 MALE EVD 25 [53.04] [38.96] [47.04] [8.36] [12.55] [41.28] [10.72] [5.84] [10.82] (SHELL SIZE 3) 2.088 1.511 1.852 0.311 0.494 1.625 0.422 0.243 0.429 FEMALE [53.04] [38.38] [47.04] [7.90] [12.55] [41.28] [10.72] [6.17] [10.90] 2.729 2.182 2.500 0.329 0.494 2.272 0.422 0.230 0.426 MALE EVD 37 [69.32] [55.42] [63.50] [8.36] [12.55] [57.71] [10.72] [5.84] [10.82] (SHELL SIZE 4) 2.729 2.159 2.500 0.311 0.494 2.272 0.422 0.243 0.429 FEMALE [69.32] [54.84] [63.50] [7.90] [12.55] [57.71] [10.72] [6.17] [10.90] 2.635 2.079 2.406 0.441 0.605 2.178 0.534 0.230 0.426 MALE EVD 50 [66.93] [52.81] [61.11] [11.20] [15.37] [55.32] [13.56] [5.84] [10.82] (SHELL SIZE 5) 2.635 2.064 2.406 0.423 0.605 2.178 0.534 0.243 0.429 FEMALE [66.93] [52.43] [61.11] [10.74] [15.37] [55.32] [13.56] [6.17] [10.90]

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 37 EVD SERIES MILITARY / INDUSTRIAL QUALITY Environmental FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS Positronic D-Sub connectpositronic.com STANDARD DENSITY REMOVABLE CONTACTS

EVD SERIES DESIGN ENVIRONMENTAL SEALING FEATURES

FEMALE CONNECTOR MALE CONNECTOR CONNECTOR CONNECTOR INSERT INSERT SEALANT INTERFACIAL SEAL SEALANT SEALING PLUG FEMALE MALE SEALING PLUG CONTACT CONTACT EVD SERIES

GROMMET FRONT FRONT GROMMET SHELL SHELL CONTACT RETENTION REAR REAR CONTACT RETENTION CLIP SHELL SHELL CLIP

SEALING PLUG NEW! ORDER SEPARATELY, PART NUMBER 4737-37-0-0

0.557 [14.16] 0.137 ø0.093 [3.48] [ø2.36]

ø0.055 [ø1.40]

INTERFACIAL SEALS AND REAR GROMMETS FOR USE WITH EVD SERIES

Interfacial seal Rear grommet 0.410 [10.41] 0.037 0.090 [0.94] A A [2.29]

B B

INTERFACIAL SEAL REAR GROMMET

CONNECTOR CONNECTOR A B VARIANT A B VARIANT 9 0.650 [16.51] 0.318 [8.08] 9 0.725 [18.42] 0.375 [9.53]

15 0.978 [24.84] 0.318 [8.08] 15 1.051 [26.70] 0.375 [9.53]

25 1.513 [38.43] 0.318 [8.08] 25 1.595 [40.51] 0.375 9.53]

37 2.156 [54.76] 0.318 [8.08] 37 2.247 [57.07] 0.375 [9.53]

50 2.058 [52.27] 0.425 [10.80] 50 2.147 [54.53] 0.490 [12.45]

DIMENSIONS ARE IN INCHES [MILLIMETERS]. Material: Fluorosilicone and silicone blend. 38 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Contact technical sales for ordering information. EVD SERIES Environmental MILITARY / INDUSTRIAL QUALITY FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS D-Sub Positronic STANDARD DENSITY REMOVABLE CONTACTS connectpositronic.com

MILITARY LEVEL REMOVABLE CRIMP CONTACT For use with EVD Series Connectors SIZE 20 Note: Connectors can be kitted with all applicable crimp contacts, FEMALE contact MALE contact contact Technical Sales for ­connector part number. “CLOSED ENTRY” DESIGN

0.538 [13.67] 0.550 [13.97] *MILITARY 0.066 0.066 SPECIFICATION CONTACTS [1.68] * Color Code * Color Code [1.68]

STANDARD FINISH: 0.000050 inch [1.27µ] gold over nickel 0.045 Stainless Steel Shroud Ø0.040 [1.02] 0.045 [1.14] [1.14] Color Code: 0.170+0.015-0.020 0.170+0.015-0.020 [4.32+0.38-0.51] [4.32+0.38-0.51] Male Contact:

ORANGE/BLUE/WHITE EVD SERIES Female Contact: FEMALE WIRE SIZE MALE WIRE SIZE ORANGE/BLUE/GRAY PART NUMBER AWG/[mm2] PART NUMBER AWG/[mm2] 20 / 22 / 24 20 / 22 / 24 *M39029/63-368 [0.5/0.3/0.25] *M39029/64-369 [0.5/0.3/0.25]

NEW! INDUSTRIAL / MILITARY LEVEL REMOVABLE CRIMP CONTACT For use with evd Series Connectors SIZE 20 FEMALE contact “CLOSED ENTRY” DESIGN MALE contact

0.066 0.538 [13.67] 0.550 [13.97] 0.066 [1.68] [1.68]

Note: Connectors can be kitted with all applicable crimp contacts, contact Technical Sales for ØA Ø0.040 [1.02] ØA ­connector part number. 0.170+0.015-0.020 0.170+0.015-0.020 [4.32+0.38-0.51] [4.32+0.38-0.51]

FEMALE WIRE SIZE ØA MALE WIRE SIZE ØA PART NUMBER AWG/[mm2] PART NUMBER AWG/[mm2] 20 / 22 / 24 0.045 20 / 22 / 24 0.045 FC6020D2-14 [0.5/0.3/0.25] [1.14] MC6020D-14 [0.5/0.3/0.25] [1.14]

PROFESSIONAL LEVEL REMOVABLE CRIMP CONTACT For use with evd Series Connectors

FEMALE contact SIZE 20 Note: Connectors can be kitted with all applicable crimp contacts, “Robi-D” Open Entry DESIGN contact Technical Sales for Ø0.045 ­connector part number. [1.14] 0.538 [13.67]

FEMALE WIRE SIZE PART NUMBER AWG/[mm2] 0.170+0.015-0.020 20 / 22 / 24 Ø0.066 FC6520D-14 [1.68] [4.32+0.38-0.51] [0.5/0.3/0.25]

For information regarding CRIMP TOOL AND CRIMPING TOOL TECHNIQUES, see page 47.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 39 EVD SERIES MILITARY / INDUSTRIAL QUALITY Environmental FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS Positronic D-Sub connectpositronic.com STANDARD DENSITY REMOVABLE CONTACTS

NEW! REMOVABLE THERMOCOUPLE CRIMP CONTACT For use with evd Series Connectors Note: Connectors can be kitted with SIZE 20 all applicable crimp contacts, contact Technical Sales for ­connector part number. FEMALE contact “CLOSED ENTRY” DESIGN Male contact

EVD SERIES 0.538 [13.67] 0.550 [13.97]

ØA * Color Code * Color Code ØA

ØB Ø0.040 [1.02] ØB 0.170+0.015-0.020 0.170+0.015-0.020 [4.32+0.38-0.51] [4.32+0.38-0.51]

TYPE MATERIAL FEMALE MALE COLOR WIRE SIZE ØA ØB PART NUMBER PART NUMBER CODE AWG [mm2] For more information on the availability of Type J 20 / 22 / 24 0.066 0.045 CHROMEL (+) †† † FC6020D2CH MC6020DCH WHITE [0.5 / 0.3 / 0.25] [1.68] [1.14] thermocouple contacts, K and ­information 20 / 22 / 24 0.066 0.045 ALUMEL (-) †† † FC6020D2AL MC6020DAL GREEN [0.5 / 0.3 / 0.25] [1.68] [1.14] about ­thermocouple ­contacts with printed 20 / 22 / 24 0.066 0.045 COPPER (+) †† † FC6020D2CU MC6020DCU RED [0.5 / 0.3 / 0.25] [1.68] [1.14] circuit board solder T termination, please 20 / 22 / 24 0.066 0.045 CONSTANTAN (-) †† † FC6020D2CO MC6020DCO YELLOW [0.5 / 0.3 / 0.25] [1.68] [1.14] contact Technical Sales.

Chromel® and 20 / 22 / 24 0.066 0.045 ® CHROMEL (+) FC6020D2CH†† MC6020DCH† WHITE Alumel are [0.5 / 0.3 / 0.25] [1.68] [1.14] registered trademarks E of Hoskins 20 / 22 / 24 0.066 0.045 Manufacturing CONSTANTAN (-) FC6020D2CO†† MC6020DCO† YELLOW [0.5 / 0.3 / 0.25] [1.68] [1.14] Company.

†Dimensionally equivalent to M39029/64-369 ††Dimensionally equivalent to M39029/63-368

For information regarding CRIMP TOOL AND CRIMPING TOOL TECHNIQUES, see page 47.

CONTACT REELS FOR AUTOMATIC PNEUMATIC CRIMP TOOLS

Reel for holding plastic contact carriers Contacts may be supplied in plastic carriers, packaged in reels holding 2,000 contacts for use with the automatic pneumatic crimp tools, catalog part numbers 9550-0 and 9550-1; packaged in reels holding 1,000 contacts­ for use with the automatic pneumatic crimp tools, catalog part number 9555-0-2. The same type ­carrier is used for both male and female contacts. All male and female crimp contacts can be ordered in Plastic contact carriers Enlarged section of reels by adding letter “R” after the contact part number, plastic contact carriers such as MC6020DR for a male contact and FC6026D2R for a female contact.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 40 ALL DIMENSIONS ARE SUBJECT TO CHANGE. EVD SERIES Environmental MILITARY / INDUSTRIAL QUALITY FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS D-Sub Positronic STANDARD DENSITY REMOVABLE CONTACTS connectpositronic.com

ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 8

STEP 1 2 3 4 5 6 7 8 9 10 EXAMPLE EVD 25 P 1 0 Z 0 S /AA

STEP 10 - SPECIAL OPTIONS Consult Technical Sales STEP 1 - Basic Series EVD Series STEP 9 - Environmental Compliance options /AA - Compliant per EU Directive 2002/95/ STEP 2 - EVD Connector Variants EC (RoHS) 9, 15, 25, 37, 50 EVD SERIES Note: If compliance to environmental ­legislation is not required, this step will STEP 3 - Connector Gender not be used. Example: EVD25P10Z0S P - Male with interfacial seal S - Female - PosiBand closed entry contact design STEP 8 - Shell Options *2 S - Stainless steel, passivated. 0 - Zinc plated with chromate seal. STEP 4 - Type of Contacts

0 - Contacts ordered separately. See pages 39 & 40 . *1 STEP 7 - Locking Systems 1 - Crimp, 20 AWG - 24 AWG [0.5 mm2 - 0.25 mm2] kitted with connector. 0 - None. Use only with ‘Z’ or ‘Z4’ (step 6). 2 - Solder, 20 AWG - 24 AWG [0.5 mm2 - 0.25 mm2] kitted T2 - Fixed female jackscrews. with connector. E - Rotating male jackscrews.

*1 STEP 5 - Mounting Style 1 0 - Mounting hole, 0.120 [3.05] diameter. * STEP 6 - Hoods F - Float mounts, universal. 0 - None. S2 - Swaged spacer, 4-40 threads, 0.125 [3.18] length. Z - Composite hood with rotating male jackscrews. S5 - Swaged locknut, 4-40 threads. Z4 - Composite hood with fixed female jackscrews.

NOTES:

*1 For additional information listed in Steps 5, 6, and 7, see the Accessories section, page 42. *2 For stainless steel dimpled male versions, contact Technical Sales.

For information regarding REMOVABLE CONTACTS, see illustration/drawing and charts on pages 39 & 40 .

Do you need 2-D drawings or 3-D models? Once you have made a connector selection, contact Techni- cal Sales if you would like a 2-D drawing or 3-D model. If we do not have your specific part number on file, we can create one for you. Or, please visit www.connectpositronic.com and use the search function.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 41 Environmental NEW! ACCESSORIES Positronic D-Sub connectpositronic.com

CUL-DE-SAC STYLE MOUNTING ACCESSORIES FOR USE WITH WD AND WDD SERIES CODE C5, C7 AND C8 (STEP 5)

INSIDE WALL

0.150 [3.81] 0.150 [3.81] 0.150 [3.81] 0.130 [3.30] 0.130 [3.30] 0.130 [3.30]

Water-tight Water-tight Water-tight OUTSIDE WALL Sealing Sealing Sealing ENCLOSURE MOUNT Not available in Unibody design. 4-40 UNC 4-40 UNC 4-40 UNC See Unique Feature Threads Threads Threads section, page 46. Mounting Bracket C5 C7 C8 STEEL, ZINC PLATE STEEL, ZINC PLATE PHOSPHOR BRONZE, WITH CHROMATE SEAL WITH CHROMATE SEAL, TIN PLATE OR STAINLESS STEEL, OR STAINLESS STEEL, PASSIVATED PASSIVATED ACCESSORIES ENCLOSURE WALL MOUNT SEALING PLATE FOR USE WITH WD AND WDD SERIES CODE A (STEP 6) OUTSIDE WALL INSIDE WALL ENCLOSURE MOUNT ENCLOSURE MOUNT Not available in Unibody design. See Unique Feature Enclosure Enclosure section, page 46.

O-ring O-ring

Sealing Plate Material: Glass filled thermoplastic

Enclosure mount Enclosure mount sealing plate sealing plate Note: Sealing plate is mounted to enclo- sure wall with jackscrews torqued 0.150 [3.81] 0.150 [3.81] to a value of 1.75 in-lb [0.20 Nm] 0.080 [2.03] max. 0.080 [2.03] max. minimum, 2.25 in-lb [0.25 Nm] maximum. UNIBODY DESIGN LEGACY DESIGN

INTERFACIAL SEAL CONNECTOR VARIANT FOR USE WITH WD, AND WDD SERIES* A B FURNISHED ON ALL MALE CONNECTORS WD WDD

9 15 0.67 [17.02] 0.34 [8.64] A 15 26 1.00 [25.40] 0.34 [8.64] *NOTE: B 25 44 1.53 [38.86] 0.34 [8.64] For information on the 37 62 2.18 [55.37] 0.34 [8.64] interfacial seal supplied Material: Thermoplastic Elastomer (TPE), with EVD Series, see 50 78 2.08 [52.83] 0.45 [11.43] SantopreneTM or equivalent. page 38.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 42 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental NEW! ACCESSORIES D-Sub Positronic connectpositronic.com

COMPOSITE HOODS FOR USE WITH WD, WDD OR EVD SERIES CODE Z OR Z4 (STEP 6)

Cable Opening CODE Z: Composite hood with rotating male jackscrews.

A C Cable Opening (Side cable opening not available for size 50 hood)

B

Typical Inserts Insert Tree Assembly Various inserts are provided to accommodate Rotating Male Jackscrews different cable sizes Typical part number: 4-40 UNC Threads, Steel, Zinc plated or Stainless Steel, passivated D25000Z00 Cable Opening PART ABC NUMBER MIN. MAXIMUM CODE Z4: Composite hood D9000Z00 1.387 1.935 0.735 0.100 0.400 x 0.570 Cable Opening with fixed female D9000Z400 [35.23] [49.15] [18.67] [2.54] [10.16] [14.48] jackscrews. D15000Z00 1.715 1.935 0.735 0.100 0.400 x 0.570 D15000Z400 [43.56] [49.15] [18.67] [2.54] [10.16] [14.48]

A C D25000Z00 2.254 2.200 0.735 0.100 0.550 x 0.570 D25000Z400 [57.25] [55.88] [18.67] [2.54] [13.97] [14.48] Cable Opening (Side cable opening not D37000Z00 2.903 2.200 0.735 0.100 0.550 0.570 available for size 50 hood) x D37000Z400 [73.74] [55.88] [18.67] [2.54] [13.97] [14.48] ACCESSORIES B D50000Z00 2.809 2.700 0.900 0.100 Ø 0.630 D50000Z400 [71.35] [68.58] [22.86] [2.54] [16.00]

Material: Composite, conductive volume resistivity [1.0 OHM-cm max]. Alternate material: Glass filled nylon, UL 94V-0. Fixed Female Jackscrews Typical part number: 4-40 UNC Threads, Steel, Zinc plated Attenuation: 40+ decibels or Stainless Steel, passivated D25000Z400

MOLDED CABLE ASSEMBLY EMI ENVIRONMENT INGRESS PROTECTION CODE IP67 AVAILABLE WITH WD, WDD AND EVD SERIES

CONTACT TECHNICAL SALES FOR MORE INFORMATION

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 43 Environmental NEW! ACCESSORIES Positronic D-Sub connectpositronic.com

ENCLOSURE WALL CUTOUT FOR CONNECTORS WD SERIES AND WDD SERIES

A 10° G Radius B

F E 0.120 Ø [3.1]

D C

SHELL A B C D E F G SIZE WD WDD MOUNTING ±0.005 ±0.005 ±0.005 ±0.005 ±0.005 ±0.005 ±0.002 0.806 0.403 0.984 0.492 0.449 0.225 0.132 Inside Wall [20.47] [10.24] [24.99] [12.50] [11.40] [5.72] [3.35] 1 9 15 0.874 0.437 0.984 0.492 0.513 0.257 0.083 Outside Wall [22.20] [11.10] [24.99] [12.50] [13.03] [6.53] [2.11] 1.134 0.567 1.312 0.656 0.449 0.225 0.132 Inside Wall [28.80] [14.40] [33.32] [16.66] [11.40] [5.72] [3.35] 2 15 26 1.202 0.601 1.312 0.656 0.513 0.257 0.083 Outside Wall [30.53] [15.27] [33.32] [16.66] [13.03] [6.53] [2.11] 1.674 0.837 1.852 0.926 0.449 0.225 0.132 Inside Wall [42.52] [21.26] [47.04] [23.52] [11.40] [5.72] [3.35] 3 25 44 1.743 0.872 1.852 0.926 0.513 0.257 0.083 Outside Wall ACCESSORIES [44.27] [22.15] [47.04] [23.52] [13.03] [6.53] [2.11] 2.326 1.163 2.500 1.250 0.449 0.225 0.132 Inside Wall [59.08] [29.54] [63.50] [31.75] [11.40] [5.72] [3.35] 4 37 62 2.391 1.196 2.500 1.250 0.513 0.257 0.083 Outside Wall [60.73] [30.38] [63.50] [31.75] [13.03] [6.53] [2.11] 2.218 1.109 2.406 1.203 0.555 0.278 0.132 Inside Wall [56.34] [28.17] [61.11] [30.57] [14.10] [7.06] [3.35] 5 50 78 2.297 1.149 2.406 1.203 0.623 0.312 0.083 Outside Wall [58.34] [29.18] [61.11] [30.57] [15.82] [7.92] [2.11]

PROTECTIVE COVER SUPPLIED AS STANDARD WITH ALL CONNECTORS WD, WDD AND EVD SERIES

COVER WITHOUT EARS (FOR CONNECTORS WITHOUT FIXED JACKSCREWS) STATIC CONDUCTIVE DISSIPATIVE REPLACEMENT WD WDD REPLACEMENT REPLACEMENT PART NUMBER EVD PART NUMBER PART NUMBER WITH EARS WITHOUT EARS WITHOUT EARS 9M 15M 4931-9-0-0 4931-9-1-0 4931-9-100-0

9F 15F 4932-9-0-0 4932-9-1-0 4932-9-100-0 Material: Conductive polyethylene Color: Black Optional : 15M 26M 4931-15-0-0 4931-15-1-0 4931-15-100-0 Material: Static dissipative ethylene vinyl acetate Optional: Pink 15F 26F 4932-15-0-0 4932-15-1-0 4932-15-100-0

COVER WITH EARS 25M 44M 4931-25-0-0 4931-25-1-0 4931-25-100-0 (FOR CONNECTORS WITH FIXED JACKSCREWS) 25F 44F 4932-25-0-0 4932-25-1-0 4932-25-100-0

37M 62M 4931-37-0-0 4931-37-1-0 4931-37-100-0

37F 62F 4932-37-0-0 4932-37-1-0 4932-37-100-0

50M 78M 4931-50-0-0 4931-50-1-0 4931-50-100-0 Material: Conductive polyester Color: Black 50F 78F 4932-50-0-0 4932-50-1-0 4932-50-100-0

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 44 ALL DIMENSIONS ARE SUBJECT TO CHANGE. NEW! Environmental NEW! UNIQUE FEATURES Positronic D-Sub connectpositronic.com

UNIQUE FEATURES

Positronic is known around the world for

offering our customers flexibility when choosing connectors.

In addition to allowing customers to create part numbers for particular applications,

Positronic offers a wide variety of features and accessories within our products.

Positronic is also eager to modify existing products to meet unique

customer requirements. If you do not find what you need

with this catalog, please contact us for assistance.

NEW! OTHER SEALED D-SUBMINIATURE CONNECTOR OPTIONS Panel mount sealing plate Silicone sealant Silicone sealant Contacts have special water-tight interference Female contact Contacts are sealed Female contact fit seal into insulator to insulator with epoxy sealant

Rear shell Front shell Rear shell Front shell MD Style Connector Epoxy sealant O-ring seal

Silicone sealant Combo-D Style Connector

Interfacial seal Silicone sealant Silicone sealant

Male contact Interfacial seal, Contacts are sealed Rear shell contact technical sales to insulator with for availability of all sizes epoxy sealant Front shell UNIQUE FEATURES Male contact ODD Style Connector Rear shell Front shell

SEALED STANDARD OR HIGH DENSITY Combo-D Style Connector D-SUBMINATURE - Available in both standard density and high density connector SEALED COMBINATION D-SUBMINATURE variants. - Could be supplied with mounting plate or without. - Standard MD or ODD series connectors can be sealed - Contact technical sales for more information or additional between the connector shell and the connector insert. contact configurations. - Contact technical sales for more information.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 45 NEW! Environmental NEW! UNIQUE FEATURES Positronic D-Sub connectpositronic.com

NEW! MACHINED ALUMINUM MOUNTING PLATE WITH CONDUCTIVE O-RING

Panel mount Enclosure shown Fixed female jackscrews sealing plate for reference only

Silicone sealant Materials and Finishes: Panel mount sealing plate - Rear shell Aluminum, yellow chromate Front shell coating. Epoxy sealant Conductive O-ring - O-ring seal Silver coated thermoplastic O-ring 0.080 [2.03] max. elastomer. panel thickness 0.150 [3.81]

0.177 [4.50]

CONTACT TECHNICAL SALES FOR MORE INFORMATION

OUTSIDE WALL ENCLOSURE MOUNT FOR APPLICATIONS REQUIRING SEALED D-SUBMINIATURE CONNECTOR TO BE MOUNTED ON THE OUTSIDE OF THE ENCLOSURE.

Enclosure

O-ring

Sealing Plate Material: Glass filled thermoplastic

Fixed female 4-40 UNC Threads Note: Sealing plate is mounted to enclosure wall with jackscrew jackscrews torqued to a value of 1.75 in-lb [0.20 Nm] Enclosure mount minimum, 2.25 in-lb [0.25 Nm] maximum. sealing plate UNIQUE FEATURES 0.150 [3.81] 0.200 [5.08] max. practical limit

CONTACT TECHNICAL SALES FOR PART NUMBER

LIGHTWEIGHT ALUMINUM HOOD

Positronic now offers a Lightweight Aluminum Hood for use with D-subminiature connectors! NEW! These hoods are offered in the following material and finish combinations: • Aluminum • Aluminum with electroless nickel plate • Aluminum with yellow anodize, • Aluminum with yellow chromate conversion, zinc content is 1% maximum.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 46 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Environmental NEW! UNIQUE FEATURES Positronic D-Sub connectpositronic.com

OTHER ENVIRONMENTAL CONNECTOR OFFERINGS

HERMETIC CONNECTORS Intended for use as an electrical feed through in high vacuum applications • Leakage rate: < 5x10-9 mbar.l/s under a vacuum 1.5x10-2 mbar • Signal, power, coax and high voltage versions available • Connectors can be mounted on flange assembly per customer specification

ENVIRONMENTAL CIRCULAR CONNECTORS Non-corrodible / lightweight composite c­ onstruction • EMI/RFI shielded versions • Thermocouple contacts • Environmentally sealed versions • Rear insertion / front release of removable contacts • Two level sequential mating • Over molding available on full assemblies

Environmental NEW! APPLICATION TOOLS Positronic D-Sub connectpositronic.com

APPLICATION TOOLS SECTION

EVD connectors are offered with removable crimp contacts. Positronic recognizes the importance of supplying application tooling to support our customers’ use of our products. Information on application tooling is available on our web site at UNIQUE FEATURES http://www.connectpositronic.com/design-tools/tooling There you will find downloadable PDF cross reference charts for removable and compliant press-in contacts. These charts will supply part numbers for insertion, removal and crimping tools, along with information regarding use of tools and techniques.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 47 APPLICATION TOOLS Environmental NEW! APPLICATION TOOLS Positronic D-Sub connectpositronic.com

CONTACT APPLICATION TOOLS CROSS REFERENCE LIST USE INDICATED POSITRONIC TOOLS FOR BEST RESULTS See note* 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 9550-1-0-0 Automatic Crimp Tool Mil. Equiv M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 Mfg. Cross 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 Tool 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 Removal Mil Equiv. M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 M81969/1-02 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 91067-2 Mfg. Cross Tool 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 4711-2-0-0 Insertion Mil Equiv, M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 M22520/2-08 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 K13-1 Mfg. Cross 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 9502-5-0-0 Positioner Mil Equiv M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 M22520/2-01 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 AFM8 Mfg. Cross APPLICATION TOOLS Tool 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 9507-0-0-0 Hand Crimp Contact Positronic Part Number MC6020DAL MC6020DCH MC6020DCU FC6020D2AL MC6020D-14 MC6020DCO FC6020D2CH FC6020D2CU FC6020D2-14 FC6020D2CO FC6520D2-14 M39029/63-368 M39029/64-369 All male and female crimp contacts can be ordered on reels in quantities of 2,000 by adding letter “R” after the contact part n umber, see page 40 for more information.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 48 ALL DIMENSIONS ARE SUBJECT TO CHANGE. APPENDIX Environmental Positronic D-Sub connectpositronic.com

EXPLANATION OF INGRESS PROTECTION (IP) SYSTEM FOR ENCLOSURES APPENDIX This system outlined in IEC 60529 is designed to indicate the standard degrees of protection: from (a) touch and ingress of solids, and (b) from ingress of liquids, which enclosures may exhibit, and must not be confused with explosion protection techniques. These degrees of protection are, however, frequently referred to in standards and literature, and hence are listed below.

The first numeral designates the degree of protection against touching live parts and ingress of solid foreign bodies, the second designates the degree of protection against ingress of liquid.

The higher the numeral of the first and second characteristic, the greater degree of protection the enclosure offers, e.g. IP55 meets all the less onerous degrees such as IP22, IP23, IP34 and IP54. The term “weatherproof” is not included at present in the IP system but IP54 enclosures are frequently described in this way.

Protection of equipment against ingress of solid bodies and liquids

SOLID FOREIGN BODIES LIQUIDS

FIRST SECOND OBJECT CHARACTERISTIC SIZE DEGREE OF PROTECTION CHARACTERISTIC DEGREE OF PROTECTION NUMERAL NUMERAL

No protection of persons against contact with live or moving parts inside the 0 0 No protection. enclosure. No protection of equipment against ingress of solid foreign bodies.

Protection against accidental or inadvertent contact with live or moving parts inside the >50 mm Protection against drops of condensed water. Drops enclosure by a large surface of the human 1 1 of condensed water falling on the enclosure shall have body, e.g. a hand, but not protection against no harmful effect. deliberate access to such parts. Protection against ingress of large solid foreign bodies.

>12.5 mm Protection against contact with live or Protection against drops of liquid. Drops of falling moving parts inside the enclosure by fingers. 2 2 liquid shall have no harmful effect when the enclosure is Protection against ingress of medium size tilted at any angle up to 15° from the vertical. solid foreign bodies.

Protection against contact with live or >2.5 mm moving parts inside the enclosure by tools, Protection against rain. Water falling in rain at an angle 3 wires or such objects of thickness greater 3 equal to or smaller than 60° with respect to the vertical than 2.5 mm. Protection against ingress of shall have no harmful effect. small solid foreign bodies.

Protection against contact with live or >1.0 mm moving parts, inside the enclosure by tools, Protection against splashing. Liquid splashed from any 4 wires or such objects of thickness greater 4 direction shall have no harmful effect. than 1 mm. Protection against ingress of small solid foreign bodies.

Complete protection against contact with live or moving parts inside the enclosure. Protection against harmful deposits of dust. Protection against water jets. Water projected by a 5 The ingress of dust is not totally prevented, 5 nozzle from any direction under stated conditions shall but dust cannot enter in an amount sufficient have no harmful effect. to interfere with satisfactory operation of the equipment enclosed.

Complete protection against contact with Protection against conditions on ships’ decks (deck 6 live or moving parts inside the enclosure. 6 watertight equipment). Water from heavy seas shall not Protection against ingress of dust. enter the enclosures under prescribed conditions.

Protection against immersion in water. It shall not be 7 possible for water to enter the enclosure under stated conditions of pressure and time.

Protection against indefinite immersion in water under 8 specified pressure. It shall not be possible for water to enter the enclosure.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 49 Environmental

APPENDIX APPENDIX Positronic D-Sub connectpositronic.com

DESCRIPTION OF NEMA ENCLOSURE TYPES

TYPE INTENDED USE AND DESCRIPTION

1 Indoor use primarily to provide a degree of protection against limited amounts of falling dirt.

2 Indoor use primarily to provide a degree of protection against limited amounts of falling water and dirt.

Outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust and damage from 3 external ice formation.

Outdoor use primarily to provide a degree of protection against rain, sleet and damage from external ice 3R formation.

Outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust and to provide for 3S operation of external mechanisms when ice laden.

Indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing 4 water, hose-directed water and damage from external ice formation.

Indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, 4X splashing water, hose-directed water and damage from external ice formation.

Indoor use primarily to provide a degree of protection against settling airborne dust, falling dirt and dripping 5 noncorrosive liquids.

Indoor or outdoor use primarily to provide a degree of protection against hose-directed water and the entry 6 of water during occasional temporary submersion at a limited depth and damage from external ice formation.

Indoor or outdoor use primarily to provide a degree of protection against hose-directed water, the entry of water 6P during prolonged submersion at a limited depth and damage from external ice formation.

Indoor use primarily to provide a degree of protection against circulating dust, falling dust, falling dirt and 12, 12K dripping noncorrosive liquids.

Indoor use primarily to provide a degree of protection against dust, spraying of water, oil and noncorrosive 13 coolant.

This material is reproduced from NEMA Standards Publication 250-1991 by permission of the National Electrical Manufacturers Association which holds the copyright.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 50 ALL DIMENSIONS ARE SUBJECT TO CHANGE. APPENDIX Environmental Positronic D-Sub connectpositronic.com

COMPARISON BETWEEN NEMA ENCLOSURE TYPE NUMBERS APPENDIX AND IEC ENCLOSURE CLASSIFICATION DESIGNATIONS

IEC Publication 60529, Classification of Degrees of Protection Provided by Enclosures, provides a system for specifying the enclosures of electrical equipment of the basis of the degree of protection provided by the enclosure. IEC 60529 does not specify degrees of protection against mechanical damage of equipment, risk of explosions or conditions such as moisture (produced for example by condensation), corrosive vapors, fungus or vermin. NEMA Standards Publication 250 does test for environmental conditions such as corrosion, rust, icing, oil and coolants. For this reason, and because the tests and evaluations for other characteristics are not identical, the IEC Enclosure Classification Designations cannot be exactly equated with NEMA Enclosure Type Numbers. The IEC designation consists of the letters IP followed by two numerals. The first characteristic numeral indicates the degree of protection provided by the first enclosure with respect to persons and solid foreign objects entering the enclosure. The second characteristic numeral indicates the degree of protection provided by the enclosure with respect to the harmful ingress of water. The Table provides an approximate equivalent conversion from NEMA Enclosure Type Numbers to IEC Enclosure Classification Designations. The NEMA Types meet or exceed the test requirements for the associated IEC Classifications; for this reason the Table cannot be used to convert exactly from IEC Classifications to NEMA Types.

Comparison of NEMA Type Numbers to IEC Classification Designations (Cannot be used to convert IEC Classification Designations to NEMA Type Numbers)

NEMA ENCLOSURE IEC ENCLOSURE TYPE NUMBER CLASSIFICATION DESIGNATION

1 IP10

2 IP11

3 IP54

3r IP14

3s IP54

4 and 4x IP56

5 IP52

6 and 6p IP67

12 and 12K IP52

13 IP54

This material is reproduced from NEMA Standards Publication 250-1991 by permission of the National Electrical Manufacturers Association which holds the copyright.

Note: This comparison is based on tests specified in IEC Publication 60529.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 51 OTHER D-SUBMINATURE PRODUCTS

Positronic offers a full line of D-subminiature connectors in a wide variety of contact variants and package sizes with press-fit, solder and cable terminations. All Positronic connector products pro- vide quality, reliability and flexibility.

HIGH PERFORMANCE D-SUBMINIATURE CONNECTORS

Standard and high density connectors manufactured to MIL-PRF-24308, Class M; Goddard Space Flight Center S-311-P-4 and Goddard Space Flight Center S-311-P-10.

COMPLIANT PRESS-IN CONNECTORS

Standard and high density connectors Straight and right angle (90º) printed board mount Low press-in force eliminates stress on printed circuit board during insertion.

COMBO-D CONNECTORS

Connectors with signal, shielded, power, thermocouple or high voltage contacts in a single package. Power press-fit terminations now available.

DUAL PORT CONNECTORS

Right angle (90º) printed board mount connectors assembled stacked to maximize real estate; contact variants 9 through 62; available in standard density high density, and mixed density.

DIMENSIONS ARE IN INCHES [MILLIMETERS]. 52 ALL DIMENSIONS ARE SUBJECT TO CHANGE. Positronic HIGH RELIABILITY Products

D-SUBMINIATURE POWER FEATURES: • High current density • Energy saving - FEATURES: Hot swap capability • Four performance levels available for low contact resistance • • AC/DC operation in a single connector best cost/performance ratio: professional, • Signal contacts for hardware management industrial, military and space-fl ight quality • Sequential mating • Blind mating • Options include high voltage, coax, • Large surface area contact mating system thermocouple and air coupling contacts; • Wide variety of accessories environmentally sealed and dual port • Customer-specifi ed contact arrangements connector packages including mixed density • Modular tooling which produces • Broad selection of accessories a single piece connector insert Contact Sizes: • Size 20 and 22 contacts suitable for 8, 16, 20 and 22 use in carrying power Current Ratings: 0, 8, 12, 16, 20, 22 and 24 To 100 amperes • IP65, IP67 Contact Sizes: Terminations: Crimp, wire solder, straight solder, right angle (90°) solder, straight To 200 amperes per contact Current Ratings: compliant press-in and right angle (90°) compliant press-in Confi gurations: Multiple variants in both standard and high densities, seven connector Terminations: Crimpsolder, and fistraight xed cable compliant connector, press-in straight and solder,right angle right (90°) angle compliant (90°) press-in housing sizes Qualifi cations: MIL-DTL-24308, GSFC S-311-P-4, GSFC S-311-P-10, Confi gurations: Multiple variants in a variety of package sizes SAE AS39029, DSCC Compliance: PICMGGSFC 2.11, S-311-P-10 PICMG 3.0, VITA 41, DSCC, GSFC S-311-P-4, RECTANGULAR CIRCULAR FEATURES: FEATURES: • Non-corrodible / lightweight composite • Two performance levels available: construction industrial quality and military quality • EMI/RFI shielded versions • A wide variety of accessories • Thermocouple contacts • Broad selection of contact arrangement • Environmentally sealed versions and package sizes • Rear insertion/ front release of removable • Connector coding device (keying) options contacts • Two level sequential mating Contact Sizes: 16, 20 and 22 Current Ratings: • Overmolding available on full assemblies To 13 amperes nominal Terminations: Crimp, wire solder, straight solder, right angle (90°) solder, and 12, 16, 20 and 22 straight compliant press-in Contact Sizes: To 25 amperes nominal Confi gurations: Multiple variants in both standard and high densities, Current Ratings: thirty package sizes Terminations: Crimp, wire solder, straight solder, and right angle (90°) solder Qualifi cations: MIL-DTL-28748, SAE AS39029, CCITT V.35 Confi gurations: Multiple variants in four package sizes Qualifi cations: Environmental protection to IP67

CABLE HERMETIC FEATURES: • Shorten the supply chain and reduce FEATURES: additional costs and delays by “cablizing” • Intended for use as an electrical your Positronic connector selection feedthrough in high vacuum applications • Overmolding available • Helium leakage rate at ambient temperature: < 5x10 • Shielded and environmentally sealed -9 a vacuum 1.5x10 mbar.l/s under versions available -2 mbar • Power cables and access boxes which • Signal, power, coax and high voltage meet the SAE J2496 specifi cation versions available • Connectors can be mounted on fl ange assembly per customer specifi cation Contact Sizes: 8, 12, 16, 20 and 22 Current Ratings: 3 Design assemblies in accordance with customer specifi cations. To 40 amperes nominal Terminations: Feedthrough is standard; fl ying leads and board mount available 3 Prepare cablized connector confi guration and performance specifi cations. upon request 3 Design each system in accordance with applicable customer, domestic, Confi gurations: See D-subminiature and circular confi gurations above and international standards. Compliance: Space-D32 3Defi ne and conduct performance and verifi cation testing.

For more information, visit www.connectpositronic.com or call your nearest Positronic sales offi ce listed on the back of this catalog. Regional Headquarters

Positronic | USA 423 N Campbell Ave +1 800 641 4054 Springfield MO 65806 USA [email protected]

Positronic | Z.I. d’Engachies 46, route d’Engachies +33 5 6263 4491 F-32020 Auch Cedex 9 France [email protected]

Positronic | Asia 3014A Ubi Rd 1 #07-01 +65 6842 1419 Singapore 408703 [email protected]

Sales Offices Positronic has local sales representation all over the world. To find the nearest sales office, please visit www.connectpositronic.com/locations