Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Dynamic and Multi-Angle Light Scattering Detection

Total Page:16

File Type:pdf, Size:1020Kb

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Dynamic and Multi-Angle Light Scattering Detection Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Dynamic and Multi-Angle Light Scattering Detection Jennifer Gough1, Robert Birdsall1, Damian Morrison1, John Champagne2 , Kyle Rogers2 1Waters Corporation, Milford, MA, USA, 2Wyatt Technology Corporation, 6330 Hollister Ave.; Santa Barbara, CA ,USA OVERVIEW INTRODUCTION Explore more detection with the Polymeric materials are an integral part of everyday tasks, and Waters® ACQUITY® Advanced there is great complexity behind the research and manufacturing of Polymer Chromatography® (APC™) these high quality and competitive products. From the simple task System and the Wyatt μDAWN™ of carrying food in biodegradable shopping bags to battling diseases multi-angle and quasi-elastic light with intricate drug delivery systems, these everyday tasks are scattering (MALS/QELS). possible through an exacting polymer process. As technologies advance, there is a drive to understand and predict material Bring the high resolution separation capabilities of APC to light scattering properties through more expansive characterization and flexible analysis. analytical instrumentation. Creative analytical solutions, ranging from high speed chromatographic separation to advanced mass Experience the simplicity of the APC/ spectrometry, have become the answer for complex product µDAWN hyphenation and the benefits knowledge.1, 2, 3 that are brought to polymer characterization. Traditional analytical solutions have often been the answer for polymer characterization. Coupling liquid chromatography (LC) with detectors such as a refractive index (RI), ultra violet or photo diode array (UV or PDA), evaporative light scattering (ELS) and fluorescence (FLR) have met traditional needs. Examples of creative analytical solutions include adding a secondary LC system for two dimensional (2D) chromatography or hyphenating the LC system with detectors such as dynamic light scattering (DLS) and multi- angle light scattering (MALS).4 LC separations with resolution and speed have not always been synonymous. Yet, with the innovative design of the Waters Advanced Polymer Chromatography (APC) system, including the robust separation column and low dispersion flow path, the system yields high resolution, short analysis times, and quick mobile phase changes. This high speed/high resolution separation technique works best with low dispersion detectors, availability and diversity of which continue to increase as the advantages of APC become more widely used in research and industry.5, 6, 7 In this study, the expansion of the Waters APC approach to the size exclusion separation is presented. The sample is diverted from the ACQUITY APC Core 1 system to a Wyatt µDAWN with MALS/QELS and RI detector while maintaining the required system dispersion control needed for the APC experiment (Figure 1).8 Figure 1. ACQUITY APC Core 1 System with post column flow to the µDAWN. TO DOWNLOAD A COPY OF THIS POSTER NOTE, VISIT WWW.WATERS.COM/POSTERS 1 EXPERIMENTAL Conditions for demonstration measurements The test conditions are based on using a high speed, high resolution ACQUITY APC SEC Core 1 System coupled to Wyatt µDAWN and Optilab UT-rEX detectors. The two sytems are connected with seven thousanths inner diameter tubing and a low pressure poly fitting from the APC PDA outlet to the µDAWN inlet. The first experimental samples evaluated are a mixture of two narrow polystyrene (PS) standards and of a 200K dalton PS standard dissolved in terahydrofuran (THF). The second experimental samples are a bovine serum albumin (BSA) standard and a protein standard mixture in aqueous buffer solution. The separations are analyzed using the Wyatt µDAWN and RI. Each system‘s respective sofware is used for their respective instrument control, data collection and data processing. SEC conditions Organic Solvent Method System: Waters APC Core 1 System Eluent: THF Flow Rate: 0.7 mL/min Sample Concentration: 1 mg/mL of each narrow standard (2 mg/mL total) Injection Volume: 10 μL Column Temp.: 40 °C Columns: Waters 4.6 x 150 mm APC XT 450 Å, 125 Å and 45 Å in series Conc. Detector: Waters ACQUITY RI detector @ 40 °C (used only when disconnected from µDAWN) LS and RI Detector: Wyatt µDAWN and Optilab UT-rEX (settings below) Coupling Tubing: 0.007 inches ID Stainless Steel tubing Aqueous Method System: Waters APC Core 1 System Eluent: Aqueous Buffer: 150mM NaCl, 20mM Phosphate, pH=6.5 Flow Rate: 0.6 mL/min Sample Concentration: 1 mg/mL of each narrow standard Injection Volume: 2 μL Column Temp.: 25 °C Columns: Waters ACQUITY BEH SEC Protein 4.6 x 150 mm 200A Conc. Detector: Waters ACQUITY RI detector @ 40 °C (used only when disconnected from µDAWN) LS and RI Detector: Wyatt µDAWN and Optilab UT-rEX (settings below) Coupling Tubing: 0.007 inches ID Stainless Steel tubing Wyatt Detector Conditions LS Detector: Wyatt µDAWN LS Temp: Ambient RI Detector: Optilab UT-rEX (25°C) Chromatographic System Control Waters Empower 3 FR3 Software and Wyatt ASTRA Software Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials 2 with Dynamic and Multi-Angle Light Scattering Detection RESULTS AND DISCUSSION The polymer samples for this study are chosen to define the separation of a polymer standard mixture and a single narrow polymer standard. The protein standards are chosen for their common use in biological and pharmaceutical fields. Comparison of the RI detector signals of the mixed polymer standards are used to assess RI resolution and analysis quality throughout the analyte flow path. The single protein is an excellent example of a biological macromolecule for confirmation of detector resolution, and the protein standard mixture adds confidence to instrumental analysis flexibility from organic solvent to aqueous chromatography within an eight hour day. Below in Figure 2 is a chromatogram of a PS narrow standard mixture of three molecular weights. The overlaid RI analysis reveals a consistent retention time for the APC and Optilab detectors. The RI data is generated from importing the APC and the Wyatt data into a spreadsheet through text files. Data confidence is increased through the comparable instrumental signal analysis in the RI chromatogram. Figure 3 shows the 200K Dalton (Da) PS correlation function and control curve from the µDAWN, which provides the hydrodynamic radius value. The MALS/QELS detection, in conjunction with RI detector, enable many calculations such as the absolute molecular weight, calculated mass, and mass fraction (Table 1). The constant RI detector response is indicative of peak/sample homogeneity (Figure 4). These polymer properties reveal material characteristics that can be helpful in determining behavior of the polymer in a product matrix or solution.9-11 12 -7.12E-04 10 -7.14E-04 APC RI -7.16E-04 8 dRI Optilab -7.18E-04 6 -7.20E-04 RIU 4 RIU µ -7.22E-04 2 -7.24E-04 0 -7.26E-04 3 5 7 9 11 -2 -7.28E-04 -4 -7.30E-04 Time (min) Table 1. Molecular weight customizable table of 200K Figure 2. APC RI signal in blue, and Optilab RI signal in Da PS. red of PS standard mix. Figure 3. MALS/QELS correlation and control graphs: Figure 4. RI is constant across 200K Da PS LS peak: 200K Da PS. consistent signal across peak. Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials 3 with Dynamic and Multi-Angle Light Scattering Detection The advantages gained by polymer characterization with the µDAWN and Optilab can also be applied to the polymer- like characteristics of proteins. The BSA analysis is demonstrated below in the table and in the chromatogram, bringing confirmation to the resolution through the exhibited monomer, dimer and trimer (Table 2 & Figure 5). The hydrodynamic radius of the BSA in Figure 6 can be used to predict the behavior of the analyte in solution. The protein standard mixture, seen in Figure 7, demonstrates the separation and detection capability of the combined systems and their flexibility to operate with an organic solvent method (normal phase) or an aqueous method (reverse phase).10, 11 The red horizontal lines near each peak in the chromatograms below represent the molar mass distribution, and these can have linear, convex or concave shape. In this study, the BSA and protein mix exhibited some non-linear behavior in their molar mass distribution. This curvature is related to detector response of an analyte. A constant detector response is indicative of a homogenous sample that is baseline resolved from neighboring peaks in the chromatogram. Deviation from a constant detector response or non-linear response can be a result of increased peak heterogeneity or non-resolved peaks.12 Table 2. Wyatt ASTRA calculations for the BSA molecular weight of peaks 1, 2, and 3. Figure 5. LS and RI chromatogram of BSA: horizontal lines denote molar mass distribution. Figure 6. MALS/QELS correlation and control graphs: BSA. Figure 7. LS and RI chromatogram of protein standard mix: horizontal lines denote molar mass distribution. Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials 4 with Dynamic and Multi-Angle Light Scattering Detection CONCLUSIONS References 1. Xian, Jun Loh; Polymers for Personal Care Products Coupling the APC, high resolution / high speed SEC and Cosmetics, Royal Society of Chemistry, Core 1 system to the Wyatt μDAWN and RI Cambridge, U.K., 2016. detectors is easily managed with the selection of 2. Srivastava, Apurva, et al. (2016), “Polymers in Drug the correct tubing diameter. Delivery”. Journal of Biosciences and Medicines 4: 69 The impact of the Wyatt detectors on -84. chromatographic band spread is minimized with 3. Montaudo, M. S., Puglisi, C., Samperi, F. and their small inter-detector dispersion design capable Montaudo, G. (1998), “Application of size exclusion of interfacing with most standard ultra high chromatography matrix-assisted laser desorption/ performance LC systems. ionization time-of-flight to the determination of molecular masses in polydisperse polymers”. Rapid In the example studied, the benefit of adding the Commun.
Recommended publications
  • An Efficient Scheme for Sampling Fast Dynamics at a Low Average Data
    An efficient scheme for sampling fast dynamics at a low average data acquisition rate A. Philippe1, S. Aime1, V. Roger1, R. Jelinek1, G. Pr´evot1, L. Berthier1, L. Cipelletti1 1- Laboratoire Charles Coulomb (L2C), UMR 5221 CNRS-Universit´ede Montpellier, Montpellier, F-France. E-mail: [email protected] Abstract. We introduce a temporal scheme for data sampling, based on a variable delay between two successive data acquisitions. The scheme is designed so as to reduce the average data flow rate, while still retaining the information on the data evolution on fast time scales. The practical implementation of the scheme is discussed and demonstrated in light scattering and microscopy experiments that probe the dynamics of colloidal suspensions using CMOS or CCD cameras as detectors. arXiv:1511.07756v1 [cond-mat.soft] 24 Nov 2015 1. Introduction Since the birth of modern science in the sixteenth century, measuring, quantifying and modelling how a system evolves in time has been one of the key challenges for physicists. For condensed matter systems comprising many particles, the time evolution is quantified by comparing system configurations at different times, or by studying the temporal fluctuations of a physical quantity directly related to the particle configuration. An example of the first approach is the particle mean squared displacement, which quantifies the average change of particle positions, as determined, e.g., in optical or confocal microscopy experiments with colloidal particles [1, 2, 3]. The second method is exemplified by dynamic light scattering (DLS) [4], which relates the temporal fluctuations of laser light scattered by the sample to its microscopic dynamics.
    [Show full text]
  • Evanescent Wave Dynamic Light Scattering of Turbid Media
    Evanescent Wave Dynamic Light Scattering of Turbid Media Antonio Giuliani*, Benoit Loppinet@ Institute for Electronic Structure and Laser, Foundation for Research and Technology Hellas, Heraklion Greece *Present address : University of Groningen, the Netherlands @ [email protected] Abstract Dynamics light scattering (DLS) is a widely used techniques to characterize dynamics in soft phases. Evanescent Wave DLS refers to the case of total internal reflection DLS that probes near interface dynamics. We here investigate the use of EWDLS for turbid sample. Using combination of ray-tracing simulation and experiments, we show that a significant fraction of the detected photons are scattered once and has phase shifts distinct from the multiple scattering fraction. It follows that the measured correlation can be separated into two contributions: a single scattering one arising from the evanescent wave scattering, providing information on motion of the "scatterers" and the associated near wall dynamics and a multiple scattering contribution originating from scattering within the bulk of the sample. In case of turbid enough samples, the latter provides diffusive wave spectroscopy (DWS) -like correlation contribution. The validity of the approach is validated using turbid colloidal dispersion at rest and under shear. At rest we used depolarized scattering to distinguish both contributions. Under shear, the two contributions can easily be distinguished as the near wall dynamics and the bulk one are well separated. Information of both the near wall flow and the bulk flow can be retrieved from a single experiment. The simple structure of the measured correlation is opening the use of EWDLS for a large range of samples.
    [Show full text]
  • Quantitative Structural Analysis of Polystyrene Nanoparticles Using Synchrotron X-Ray Scattering and Dynamic Light Scattering
    polymers Article Quantitative Structural Analysis of Polystyrene Nanoparticles Using Synchrotron X-ray Scattering and Dynamic Light Scattering Jia Chyi Wong 1,2, Li Xiang 2, Kuan Hoon Ngoi 1,2, Chin Hua Chia 1,* , Kyeong Sik Jin 3,* and Moonhor Ree 2,* 1 Materials Science Program, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia; [email protected] (J.C.W.); [email protected] (K.H.N.) 2 Department of Chemistry, Polymer Research Institute, and Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 37673, Korea; [email protected] 3 Pohang Accelerator Laboratory, Pohang University of Science & Technology, Pohang 37673, Korea * Correspondence: [email protected] (C.H.C.); [email protected] (K.S.J.); [email protected] (M.R.) Received: 1 February 2020; Accepted: 18 February 2020; Published: 19 February 2020 Abstract: A series of polystyrene nanoparticles (PS-1, PS-2, PS-3, and PS-4) in aqueous solutions were investigated in terms of morphological structure, size, and size distribution. Synchrotron small-angle X-ray scattering analysis (SAXS) was carried out, providing morphology details, size and size distribution on the particles. PS-1, PS-2, and PS-3 were confirmed to behave two-phase (core and shell) spherical shapes, whereas PS-4 exhibited a single-phase spherical shape. They all revealed very narrow unimodal size distributions. The structural parameter details including radial density profile were determined. In addition, the presence of surfactant molecules and their assemblies were detected for all particle solutions, which could originate from their surfactant-assisted emulsion polymerizations.
    [Show full text]
  • Pecora R (2000) DLS Measurements of Nm Particles in Liquids
    Journal of Nanoparticle Research 2: 123–131, 2000. © 2000 Kluwer Academic Publishers. Printed in the Netherlands. Invited paper Dynamic light scattering measurement of nanometer particles in liquids R. Pecora Department of Chemistry, Stanford University, Stanford, CA 94305-5080, USA (E-mail: [email protected]) Received 15 January 2000; accepted in revised form 14 June 2000 Key words: nanoparticle, characterization, light scattering, PCS, interferometry, diffusion, polydispersivity Abstract Dynamic light scattering (DLS) techniques for studying sizes and shapes of nanoparticles in liquids are reviewed. In photon correlation spectroscopy (PCS), the time fluctuations in the intensity of light scattered by the particle dispersion are monitored. For dilute dispersions of spherical nanoparticles, the decay rate of the time autocorrelation function of these intensity fluctuations is used to directly measure the particle translational diffusion coefficient, which is in turn related to the particle hydrodynamic radius. For a spherical particle, the hydrodynamic radius is essentially the same as the geometric particle radius (including any possible solvation layers). PCS is one of the most commonly used methods for measuring radii of submicron size particles in liquid dispersions. Depolarized Fabry-Perot interferometry (FPI) is a less common dynamic light scattering technique that is applicable to opti- cally anisotropic nanoparticles. In FPI the frequency broadening of laser light scattered by the particles is analyzed. This broadening is proportional to the particle rotational diffusion coefficient, which is in turn related to the par- ticle dimensions. The translational diffusion coefficient measured by PCS and the rotational diffusion coefficient measured by depolarized FPI may be combined to obtain the dimensions of non-spherical particles.
    [Show full text]
  • Why Are DLS Measurements in High Concentration Solutions Difficult?
    Why are DLS measurements in high concentration solutions difficult? Brookhaven Instruments • Holtsville, New York Dynamic Light Scattering (DLS) is an effective measurement technique used for measuring the hydrodynamic size of common nanomaterials including colloids, nanoparticles, proteins, and polymers. Despite the versatility of this technique, there are several important considerations that cannot be ignored when using light scattering to characterize high-concentration solutions. While it is possible to make measurements on high volume-fraction samples without dilution, it raises additional questions about the meaning of the hydrodynamic size. To understand why this is the case we need to discuss two effects encountered in concentrated solutions: multiple scattering and mutual diffusion. Equivalent Hydrodynamic Size The size obtained from DLS is a hydrodynamic size, which is derived from measurements of particle diffusion. All freely diffusing particles are constantly undergoing Brownian Motion in proportion to thermal energy expressed as the product of the Boltzmann constant by the temperature (kbT). A single particle would experience Brownian Diffusion in inverse proportion to its size, thus the diffusion coefficient, DT, of this particle can be used to calculate its hydrodynamic diameter, dH, as shown in the Stokes-Einstein equation: DT = kb T / 3πηdH dH can be obtained if the temperature, T, and viscosity, η, are also known. This single particle diffusion coefficient is the result of self-diffusion; therefore, in the limit of infinite dilution, this calculated size is fully equivalent to its hydrodynamic size. In the simplest case a single decay rate, Г, is extracted from the DLS autocorrelation function (ACF). This Г is the reciprocal of the characteristic relaxation time, τt, such that: g(1)( τ) = exp(-Г τ) Figure 1.0 Simulated ACF’s for decay rates of Г = 7000, 4000, and 1000 s-1 (corresponding to 24, 41, and 165 nm diameter spherical particles).
    [Show full text]
  • Introduction to Dynamic Light Scattering for Particle Size Determination
    www.horiba.com/us/particle Jeffrey Bodycomb, Ph.D. Introduction to Dynamic Light Scattering for Particle Size Determination © 2016 HORIBA, Ltd. All rights reserved. 1 Sizing Techniques 0.001 0.01 0.1 1 10 100 1000 Nano-Metric Fine Coarse SizeSize Colloidal Macromolecules Powders AppsApps Suspensions and Slurries Electron Microscope Acoustic Spectroscopy Sieves Light Obscuration Laser Diffraction – LA-960 Electrozone Sensing Methods DLS – SZ-100 Sedimentation Disc-Centrifuge Image Analysis PSA300, Camsizer © 2016 HORIBA, Ltd. All rights reserved. 3 Two Approaches to Image Analysis Dynamic: Static: particles flow past camera particles fixed on slide, stage moves slide 0.5 – 1000 um 1 – 3000 um 2000 um w/1.25 objective © 2016 HORIBA, Ltd. All rights reserved. 4 Laser Diffraction Laser Diffraction •Particle size 0.01 – 3000 µm •Converts scattered light to particle size distribution •Quick, repeatable •Most common technique •Suspensions & powders © 2016 HORIBA, Ltd. All rights reserved. 5 Laser Diffraction Suspension Powders Silica ~ 30 nm Coffee Results 0.3 – 1 mm 14 100 90 12 80 10 70 60 8 50 q(%) 6 40 4 30 20 2 10 0 0 10.00 100.0 1000 3000 Diameter(µm) © 2016 HORIBA, Ltd. All rights reserved. 6 What is Dynamic Light Scattering? • Dynamic light scattering refers to measurement and interpretation of light scattering data on a microsecond time scale. • Dynamic light scattering can be used to determine – Particle/molecular size – Size distribution – Relaxations in complex fluids © 2016 HORIBA, Ltd. All rights reserved. 7 Other Light Scattering Techniques • Static Light Scattering: over a duration of ~1 second. Used for determining particle size (diameters greater than 10 nm), polymer molecular weight, 2nd virial coefficient, Rg.
    [Show full text]
  • "Characterization of Protein Oligomers by Multi-Angle Light Scattering" In
    and additional structural information. Studying protein Characterization of Protein oligomerization using Light scattering (LS) methods is Oligomers by Multi-angle Light combined in many cases with chromatographic methods, resulting in accurate characterization of this dynamic Scattering process with minimal measurement-related interferences. Here, we describe several light scattering-based techniques combined with several separation methods, focusing on Mai Shamir, Hadar Amartely, Mario Lebendiker, the more common method of size exclusion chromatog- Assaf Friedler raphy – multi-angle light scattering (SEC-MALS) and two The Hebrew University of Jerusalem, Jerusalem, additional and in some cases complementary methods, Israel ion exchange chromatography and flow field fractionation combined with MALS. 1 Introduction 1 2 Methods for Studying Protein 1 INTRODUCTION Oligomerization 2 3 Light Scattering of Macromolecules 3 Protein oligomerization is a fundamental process in cell biology, where two or more polypeptide chains are 4 Static Light Scattering 3 interacting, usually in a noncovalent way, to form the 4.1 The Dependence of the Static Light active form of the protein. Proteins can form homo or Scattering Intensity on the Protein Molar hetero-oligomers. Over 35% of the proteins in the cell Mass and Concentration 4 are oligomers and over half of them are homodimers or 4.2 The Dependence of Static Light Scattering homotetramers (Figure 1).(1,2) Protein oligomerization Intensity on the Protein Size 4 is at the basis of a large variety of cellular processes(3): 5 Dynamic Light Scattering 5 Oligomers provide diversity and specificity of many 6 Light Scattering Intensity in Oligomerization pathways by regulation or activation, including gene Process 7 expression, activity of enzymes, ion channels, receptors, (4–7) 7 Chromatographic Separation Coupled with and cell–cell adhesion processes.
    [Show full text]
  • Dynamic Light Scattering: an Introduction in 30 Minutes
    TECHNICAL NOTE Dynamic Light Scattering: An Introduction in 30 Minutes PARTICLE SIZE Introduction Dynamic Light Scattering (DLS), sometimes referred to as Photon Correlation Spectroscopy or Quasi-Elastic Light Scattering, is a technique classically used for measuring the size of particles typically in the sub-micron region, dispersed in a liquid. The sensitivity of some modern systems is such that it can also now be used to measure the size of macromolecules in solution, e.g. proteins Brownian Motion DLS measures Brownian motion and relates this to the size of the particles. Brownian motion is the random movement of particles due to the bombardment by the solvent molecules that surround them. The larger the particle or molecule, the slower the Brownian motion will be. Smaller particles are "kicked" further by the solvent molecules and move more rapidly. An accurately known temperature is necessary for DLS because knowledge of the viscosity is required (because the viscosity of a liquid is related to its temperature). The temperature also needs to be stable, otherwise convection currents in the sample will cause non-random movements that will ruin the correct interpretation of size. The velocity of the Brownian motion is defined by a property known as the translational diffusion coefficient (usually given the symbol, D). The Hydrodynamic Diameter The size of a particle is calculated from the translational diffusion coefficient by using the Stokes-Einstein equation; Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact ©2017 Malvern Instruments Limited TECHNICAL NOTE where:- d(H) = hydrodynamic diameter D = translational diffusion coefficient k = Boltzmann's constant T = absolute temperature η = viscosity Note that the diameter that is measured in DLS is a value that refers to how a particle diffuses within a fluid so it is referred to as a hydrodynamic diameter.
    [Show full text]
  • 1 Measurement of Dynamic Light Scattering Intensity in Gels
    Measurement of dynamic light scattering intensity in gels Cyrille Rochas1and Erik Geissler2,3* 1 Univ. Grenoble Alpes, CNRS, CERMAV, F-38000 Grenoble, France 2 Univ. Grenoble Alpes, LIPhy, F-38000 Grenoble, France 3 CNRS, LIPhy, F-38000 Grenoble, France * [email protected] Abstract In the scientific literature little attention has been given to the use of dynamic light scattering (DLS) as a tool for extracting the thermodynamic information contained in the absolute intensity of light scattered by gels. In this article we show that DLS yields reliable measurements of the intensity of light scattered by the thermodynamic fluctuations, not only in aqueous polymer solutions, but also in hydrogels. In hydrogels, light scattered by osmotic fluctuations is heterodyned by that from static or slowly varying inhomogeneities. The two components are separable owing to their different time scales, giving good experimental agreement with macroscopic measurements of the osmotic pressure. DLS measurements in gels are, however, tributary to depolarised light scattering from the network as well as to multiple light scattering. The paper examines these effects, as well as the instrumental corrections required to determine the osmotic modulus. For guest polymers trapped in a hydrogel the measured intensity, extrapolated to zero concentration, is identical to that found by static light scattering from the same polymers in solution. The gel environment modifies the second and third virial coefficients, providing a means of evaluating the interaction between the polymers and the gel. Introduction In the arsenal of techniques for characterising polymers and suspensions of solids, dynamic light scattering (DLS) is one of the more powerful weapons 1-3.
    [Show full text]
  • Multiple Scattering Effects on Intercept, Size, Polydispersity Index
    www.nature.com/scientificreports OPEN Multiple scattering efects on intercept, size, polydispersity index, and intensity for parallel (VV) and perpendicular (VH) polarization detection in photon correlation spectroscopy Ragy Ragheb* & Ulf Nobbmann Dynamic light scattering (DLS) is well established for rapid size, polydispersity, and size distribution determination of colloidal samples. While there are limitations in size range, resolution, and concentration, the technique has found ubiquitous applications from molecules to particles. With the ease of use of today’s commercial DLS instrumentation comes an inherent danger of misinterpretation or misapplication at the borderlines of suitability. In this paper, we show how comparison of diferent polarization components can help ascertain the presence of unwanted multiple scattering, which can lead to false conclusions about a sample’s mean size and polydispersity. We fnd that the contribution of multiple scattering events efectively reduces both the measured scattering intensity and the apparent size from the autocorrelation function. The intercept of the correlation function may serve as an indicator of relative strength of single to multiple scattering. Furthermore, the abundance of single scattering events at measurement positions close to the cell wall results in an apparent increase in uniformity yielding a lower polydispersity index which is more representative of the physical system. In dynamic light scattering (DLS), the scattered light from a dispersion containing difusing particles is correlated with itself. Tis technique is also known as photon correlation spectroscopy. Typically, the intensity-intensity autocorrelation function, G(τ), then shows a decay rate that is directly related to the Brownian movement of the scattering objects1–3. Equation 1 (below) expresses the intensity-intensity autocorrelation function for the ideal experimental scenario of identical particles with difusion coefcient, D, using the Siegert relationship 4.
    [Show full text]
  • Essential Biophysical Characterization: the Light Scattering Toolbox from Wyatt Technology
    Biotherapeutics Applications Essential Biophysical Characterization: The Light Scattering Toolbox from Wyatt Technology Molar Mass Analysis by SEC-MALS Two light scattering flavors for characterization of Traditional SEC relies on biomacromolecules and the assumptions that both bionanoparticles samples and references Multi-Angle static Light Scattering are identical in terms of: (MALS) measures absolute molar mass and size, in solution, via the scattered n Conformation intensity and its angular dependence. n Density A first-principles relationship links these n Hydrophobicity experimental quantities to the product of the molar mass and concentration. These assumptions are By measuring the concentration and often invalid and lead the intensity of scattered light vs. angle, it is to erroneous molar possible to determine mass values, exemplified by tetrameric hemoglobin. The late retention time molar mass and size, would indicate a much lower molar mass for Hb than BSA, even though these independently of elution time or molecular refer- two proteins in fact have very similar molecular weights. MALS provides ence standards. accurate molar masses (dots in graph). MALS is most often utilized in conjunction with a separation technique such as MALS determines molar mass entirely independently of elution time, size-exclusion chromatography for accu- resulting in the correct analysis of Hb. The decreasing molar mass rate characterization of biomacromole- values at late elution times identified by MALS are due to hemoglobin’s cules and bionanoparticles, fragments, oligomers, aggregates and conjugates. well-known tetramer-dimer dissociation (see Hb’s asymmetric peak). scattering volume laser polarization θ SEC-MALS Instrumentation for Molar Mass & Size detector Wyatt’s DAWN® HELEOS® or miniDAWN™ TREOS® MALS detectors interface Dynamic Light Scattering (DLS) with any HPLC-SEC/GPC to create a robust SEC-MALS system for measuring measures the rate of fluctuations of the scattered intensity in order to determine molar mass from 200 Da - 1 GDa, and radii from 10-1000 nm.
    [Show full text]
  • Light Scattering a Brief Introduction
    Light Scattering a brief introduction Lars Øgendal University of Copenhagen 3rd May 2019 ii Contents 1 Introduction 5 1.1 What is light scattering? . 5 2 Light scattering methods 13 2.1 Static light scattering, SLS . 13 2.2 Dynamic light scattering, DLS . 31 2.3 Comments and comparisons . 40 3 Complementary methods 45 3.1 SLS, static light scattering . 45 3.2 SAXS, small angle X-ray scattering . 46 3.3 SANS, small angle neutron scattering . 46 3.4 Osmometry . 47 3.5 MS, mass spectrometry . 47 3.6 Analytical ultracentrifugation . 48 1 2 Contents Preface The reader I had in mind when I wrote this small set of lecture notes is the absolute novice. Light scattering techniques are becoming increasingly popular but appar- ently no simple introduction to the field exists. I have tried to explain what the phenomenon of light scattering is and how the phenomenon evolved into measure- ment techniques. The field is full of pitfalls, and the manufacturers of light scatter- ing equipment dont’t emphasize this. For obvious reasons. Light scattering equip- ment is often sold as simple-to-use devices, like e.g. a spectrophotometer. And the apparatus software generally produces beautiful graphs of molecular weight or size distributions. Deceptively informative. But be warned! The information should often come with several cave at’s and the actual information content may be smaller and more doubtful than it is pleasant to realize. Before you begin to use light scattering in your projects make sure to team up with someone who has actually worked with it for some years.
    [Show full text]