LT-6045SEC MMX Application Guide

Total Page:16

File Type:pdf, Size:1020Kb

LT-6045SEC MMX Application Guide MMX LT-6045SEC Rev. 0 Application Guide November 2016 Table of Contents 1.0 Introduction 15 2.0 Working with the Fire Alarm Control Panel and the Configurator 16 2.1 Connecting the Configurator to the Fire Alarm Control Panel ........................................ 16 2.1.1 Inserting the CodeMeter Key .......................................................................................... 17 2.1.2 Connecting the Computer ............................................................................................... 17 2.2 Sending a Job to the Fire Alarm Control Panel .............................................................. 18 2.3 Getting the Active Job from the Fire Alarm Control Panel .............................................. 19 2.4 Exporting a Job ............................................................................................................... 20 2.4.1 Exporting a job as a database file or an XML file ........................................................... 20 2.5 Managing Jobs ............................................................................................................... 20 2.6 Changing the Active Job ................................................................................................. 21 2.6.1 Changing the Active Job using the Fire Alarm Control Panel ......................................... 21 2.6.2 Changing the Active Job using the Configurator ............................................................ 22 2.7 Deleting a Job ................................................................................................................. 22 2.8 Getting Configuration Information ................................................................................... 22 2.8.1 Getting Configuration Information from the Configurator ................................................ 23 2.8.2 Getting Configuration Information from the Fire Alarm Control Panel ............................ 24 2.9 Getting Information about the CodeMeter Key ............................................................... 24 2.10 Restarting the Fire Alarm Control Panel ......................................................................... 25 2.10.1 Performing a Network Restart of the Fire Alarm Control Panel ...................................... 26 2.10.2 Performing a Network Restart of a Single CPU .............................................................. 26 2.10.3 Performing a Hard Restart of the Fire Alarm Control System ........................................ 26 2.11 Watchdog Jumpers ......................................................................................................... 27 3.0 Upgrading Firmware 29 3.1 Upgrading Firmware ....................................................................................................... 29 4.0 System Limits 32 4.1 MMX System Limits ........................................................................................................ 32 4.2 Frames ........................................................................................................................... 33 5.0 Advanced Logic 36 5.1 Overview of the Advanced Logic Editor .......................................................................... 36 5.1.1 Inputs List ....................................................................................................................... 37 5.1.2 Device Status ................................................................................................................. 38 3 Table of Contents 5.1.3 Operators ........................................................................................................................ 38 5.1.4 Using brackets ................................................................................................................ 39 5.1.5 Equation Box .................................................................................................................. 40 5.1.6 Description Box .............................................................................................................. 40 5.1.7 Comment Box ................................................................................................................. 40 5.2 Example of Advanced Logic with AND ........................................................................... 40 5.2.1 Creating a zone .............................................................................................................. 41 5.2.2 Correlating the zone with an input using advanced logic ............................................... 41 5.2.3 Correlating the zone with an output ................................................................................ 41 5.3 Example of Advanced Logic with OR ............................................................................. 42 5.4 Example of Advanced Logic with NOT ........................................................................... 42 5.5 Example of Advanced Logic with ANY ........................................................................... 43 5.6 Example of Advanced Logic with EQU ........................................................................... 44 5.7 Using a Dummy Input ..................................................................................................... 44 5.8 Example of Advanced Logic with Mass Notification ....................................................... 45 5.8.1 The Mass Notification System ........................................................................................ 45 5.8.2 Assigning the nodes to the groups ................................................................................. 45 5.8.3 Assigning switches to the groups ................................................................................... 46 5.8.4 Assigning zones to the nodes ......................................................................................... 46 5.8.5 Using advanced logic to communicate between groups ................................................ 47 5.9 Complex Advanced Logic Example ................................................................................ 47 5.9.1 Objective ......................................................................................................................... 47 5.9.2 Creating a zone and inputs ............................................................................................. 48 5.9.3 Adding an equation to the zone ...................................................................................... 48 5.9.4 Correlating the zone with an output ................................................................................ 50 6.0 Testing UUKL Devices 51 6.1 Configuring a UUKL Smoke Control Test Interval .......................................................... 51 7.0 Walk Test 53 7.1 One Man Walk Test ........................................................................................................ 53 7.1.1 Results ............................................................................................................................ 54 7.2 Assisted Walk Test ......................................................................................................... 55 7.2.1 Results ............................................................................................................................ 56 7.3 Walk Test Report ............................................................................................................ 57 7.4 Configuring Walk Test Areas .......................................................................................... 60 8.0 Custom Timers and Intervals 62 8.1 Custom Timers ............................................................................................................... 62 8.1.1 Creating a custom timer ................................................................................................. 62 8.1.2 Correlating the timer with an input .................................................................................. 63 8.1.3 Correlating a zone with the timer .................................................................................... 63 4 Table of Contents 8.1.4 Correlating the zone with an output ................................................................................ 64 8.2 Custom Intervals ............................................................................................................. 64 9.0 Zone Latching 66 9.1 Zone Latching Sequence ................................................................................................ 66 9.2 Creating a Zone Latching Sequence .............................................................................. 67 9.3 Creating a Latching Zone with a Timer ........................................................................... 67 10.0 Relay Pulsing 68 10.1 Relay Pulsing Sequence ................................................................................................ 68 10.2 Creating a Relay Pulsing Sequence ............................................................................... 68 10.3 Relay Pulsing with Multiple Switches ............................................................................. 70 11.0 Hardware Layouts 71 11.1 Hardware Nomenclature ................................................................................................. 71 11.2 Chassis ........................................................................................................................... 72 11.3 Display
Recommended publications
  • Product Line Brochure
    Innovation that Endures www.fi relite.com Addressable Fire Alarm Control Panels MS-9050UD, MS-9200UDLS and MS-9600LS/MS-9600UDLS Addressability Within Reach Fire-Lite Alarms’ addressable product offering includes three Fire MS-9050UD Alarm control panels that vary in size and capability to meet a wide • Single SLC that provides support for 50 addressable devices (any combination range of needs, while offering superior value and fl exibility. Our ad- of addressable detectors and modules) dressable product line offers ease of installation and programming, • Integrated DACT for off-premises monitoring addressable point identifi cation, built-in digital communication, and • Annunciator bus supports up to 8 devices, including ANN-80 LCD remote NAC synchronization. Our super fast LiteSpeedTM protocol ensures that annunciator, remote serial or parallel printer gateway, and LED graphic annunciator the safety and security of your building and its occupants are always • Auto programming feature quickly confi gures detectors and modules met with the utmost urgency. Fire-Lite’s addressable product line sets • Two programmable Class B / A notifi cation appliance circuits (NAC) the benchmark for Fire protection with its innovative, non-proprietary, cost effective products. MS-9200UDLS Included features on our most popular addressable panels: • Single SLC provides support for 198 addressable devices • Ability to connect devices via unshielded “fi re” wire up to 10,000 • LiteSpeed protocol for SLC communication polls 10 devices at a time and operates feet,
    [Show full text]
  • Fire Service Features of Buildings and Fire Protection Systems
    Fire Service Features of Buildings and Fire Protection Systems OSHA 3256-09R 2015 Occupational Safety and Health Act of 1970 “To assure safe and healthful working conditions for working men and women; by authorizing enforcement of the standards developed under the Act; by assisting and encouraging the States in their efforts to assure safe and healthful working conditions; by providing for research, information, education, and training in the field of occupational safety and health.” This publication provides a general overview of a particular standards- related topic. This publication does not alter or determine compliance responsibilities which are set forth in OSHA standards and the Occupational Safety and Health Act. Moreover, because interpretations and enforcement policy may change over time, for additional guidance on OSHA compliance requirements the reader should consult current administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts. Material contained in this publication is in the public domain and may be reproduced, fully or partially, without permission. Source credit is requested but not required. This information will be made available to sensory-impaired individuals upon request. Voice phone: (202) 693-1999; teletypewriter (TTY) number: 1-877-889-5627. This guidance document is not a standard or regulation, and it creates no new legal obligations. It contains recommendations as well as descriptions of mandatory safety and health standards. The recommendations are advisory in nature, informational in content, and are intended to assist employers in providing a safe and healthful workplace. The Occupational Safety and Health Act requires employers to comply with safety and health standards and regulations promulgated by OSHA or by a state with an OSHA-approved state plan.
    [Show full text]
  • Rules and Regulations for Fire Alarm and Fire Sprinkler Systems
    NORTH ATTLEBOROUGH FIRE DEPARTMENT 50 Elm Street, North Attleborough, Massachusetts 02760 Tel (508) 699-0140 • Fax (508) 643-0296 Issued: January 2020 Revised 02/10/2020 Rules and Regulations for Fire Alarm and Fire Sprinkler Systems The following rules and regulations shall govern the installation, use, and maintenance of all required fire alarm and fire sprinkler systems in the Town of North Attleborough. The rules and regulations are effective January 1, 2020 until otherwise revised or amended. They are intended to cover the most common variables encountered by architects, engineers, fire alarm and fire suppression professionals. These rules and regulations are subject to change and at no time should be considered complete towards all projects and scopes of work. Consult the fire prevention office after reading this document where additional clarification is required. Contents Section 1: General Requirements: ................................................................................................................... 2 Section 2: Engineer/Contractor Submittal and Plan Review ......................................................................... 3 Section 3: Interior System Design and Layout ............................................................................................... 6 Section 4: Sprinkler and Standpipe Systems ................................................................................................ 11 Section 5: Direct Connections to the North Attleborough Fire Department ..............................................
    [Show full text]
  • LT-2001 MR-2100 2200 Programming Manual-1
    MR-2100 & MR-2200 Fire Alarm Control Panel Programming Manual © Secutron LT-2001 Rev.3.1 June 2018 Table of Contents 1.0 Operation and Programming Concepts ..........................................................................1 1.1 Introduction ....................................................................................................................1 1.2 General Information .......................................................................................................2 1.3 Networks ........................................................................................................................2 1.4 Addressable Devices .....................................................................................................5 1.5 Resetting 4-Wire Detectors ............................................................................................8 2.0 Editing MHI Databases .....................................................................................................10 2.1 Introduction ....................................................................................................................10 2.2 General Comments ........................................................................................................10 2.3 System Window .............................................................................................................11 2.4 Switches Window ...........................................................................................................15 2.5 Groups Window .............................................................................................................17
    [Show full text]
  • AFC-50 Fire Alarm Control Panel
    AFC-50 Fire Alarm Control Panel Features • 50 addresses available on this analog addressable system • Additional system capacity achieved via multi-point SLC modules • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built-In • System Operates as Class A or Class B for SLC, P-Link and NACs • 5 Amp Power Supply, Expandable to 310 amps • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP Communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information NYC Fire Dept. • Product includes 5 year warranty. Certificate of Approval 6256 7165-0328:0509 S735 Description Technical Specifications The AFC-50 is an analog/addressable fire alarm system with a total system 7 capacity of 50 addresses. Additional capacity on the system is achieved Dimensions 16”W x 17”H x 3 /8”D using multi-point SLC modules. The control panel utilizes the exclusive 3.0 Amps @ 120 VAC 50/60 HZ AC Mains Potter protocol that includes a complete line of sensors and modules. 2.0 Amps @ 240 VAC 50/60 HZ Each SLC may be comprised of any combination of smoke sensor, heat 16 gauge cold rolled steel with removable detectors or modules and allows for a total of 50 ohms of impedance and Enclosure locked door with Lexan viewing window may use any wire compliant with the National Electrical Code (NEC).
    [Show full text]
  • Simplex 4100ES Operator's Manual
    FIRE FIRE FIRE 4100ES Fire Alarm System Operator’s Manual 579-197 Rev. G 574-xxx Rev. 4 Blank Page- Back of Front Cover Copyrights and Trademarks 2007, 2008, 2011 SimplexGrinnell LP. All rights reserved. Simplex and the Simplex logo are registered trademarks of Tyco International Ltd. and its affiliates and are used under license. Specifications and other information shown were current as of publication and are subject to change without notice. Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS. Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depend upon proper installation. ® DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. STATIC HAZARD - Static electricity can damage components. Handle as follows: Ground yourself before opening or installing components. Prior to installation, keep components wrapped in anti-static material at all times. EYE SAFETY HAZARD - Under certain fiber optic application conditions, the optical output of this device may exceed eye safety limits. Do not use magnification (such as a microscope or other focusing equipment) when viewing the output of this device. FCC RULES AND REGULATIONS – PART 15 – This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
    [Show full text]
  • Addressable Fire Alarm Control Panel Installation and Operation Manual
    6700 Addressable Fire Alarm Control Panel Installation and Operation Manual Document LS10148-001SK-E Rev:C 09/28/2017 ECN: 17-0555 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! An automatic fire alarm system—typically made up of smoke Heat detectors do not sense particles of combustion and alarm detectors, heat detectors, manual pull stations, audible warning only when heat on their sensors increases at a predetermined rate devices, and a fire alarm control panel (FACP) with remote notifica- or reaches a predetermined level. Rate-of-rise heat detectors may tion capability—can provide early warning of a developing fire. be subject to reduced sensitivity over time. For this reason, the Such a system, however, does not assure protection against prop- rate-of-rise feature of each detector should be tested at least once erty damage or loss of life resulting from a fire. per year by a qualified fire protection specialist. Heat detectors are An emergency communication system—typically made up of an designed to protect property, not life. automatic fire alarm system (as described above) and a life safety IMPORTANT! Smoke detectors must be installed in the same communication system that may include an autonomous control room as the control panel and in rooms used by the system for the unit (ACU), local operating console (LOC), voice communication, connection of alarm transmission wiring, communications, signal- and other various inter-operable communication methods—can ing, and/or power. If detectors are not so located, a developing fire broadcast a mass notification message.
    [Show full text]
  • Technical Specifications of Fire Alarm Panel and Repeater Panel
    Technical specifications of Fire Alarm panel and repeater Panel Scope of tender: This covers supply, installation and commissioning of Main Fire Alarm panels and Repeater Panel and their interfacing with already existing detectors, MCP (Manual call points) and sounder modules. These Detectors, MCP, sounder modules, Flame detectors, input and output modules are already installed at our site. Cables for interfacing such detectors and devices are already laid in field. LAN infrastructure for connection between Main Fire Alarm Panel and repeater panel are already present at site. 1. Main fire alarm panel (2 loop panel) Main Fire Alarm Panel (MFAP) shall communicate with two loops of fire detectors and alarm system consisting of fire detectors, Sounder modules and manual call point. Fire detected by Apollo make sensors viz. Discovery and XP 95 based smoke detectors/multi sense detectors and heat detectors shall be communicated to main fire alarm panel. MFAP should be able to communicate to three Nos. of repeater panel through two communication protocols: over Ethernet LAN infrastructure using TCP /IP network and also over a pair of shielded twisted pair cable (RS 485, MODBUS). All other diagnostic event associated with detectors shall be reported and shown in Main fire alarm panel (MFAP) and 3 Nos. of repeater panel. Total no. of detectors, sounder modules and manual call points are around 70 Nos. each in loop (total no. of loops are 2) which are already installed at our site. Cable for these detectors, sounder modules and Manual Call Point are already laid at site up to the site of panel installation.
    [Show full text]
  • Fire Alarm Systems Design Guide
    UNIVERSITY OF WASHINGTON Electrical Environmental Health & Safety Design Guide Fire Alarm System Basis of Design The purpose of this section is to provide the guidelines for the development of the design of fire alarm systems. Background New facilities and facilities to be substantially renovated must include a fire alarm system. Exceptions include small buildings and temporary facilities where little value is added by provision of an alarm system. Discuss exceptions with Environmental Health and Safety (EH&S). Fire alarm systems at the Seattle campus are maintained by Campus Engineering and Operations. As a result the University has found it cost effective to develop specific standards for design, installation and acceptance of fire alarm systems. The standards include a sole-source justification for Simplex fire alarm systems. Please use the UW Fire Alarm Guide Specification and discuss deviations with Environmental Health and Safety. The guide specification requires customization to suit a specific project. University buildings not located on the main campus are maintained through service contract. The sole source with Simplex as referenced above does not apply. Projects should list at least three locally represented fire alarm manufacturers. The vendors must meet our pre-determined standardized qualifications as outlined in the guide specification. The UW Fire Protection Engineer should be consulted for assistance in this selection process. Buildings on the Seattle campus are monitored by the University’s TrueSite system typically achieved through fiber optic cable in the utility tunnel. The UW Fire Protection Engineer within EH&S is responsible to review and approve fire alarm design for UW facilities. Renovated facilities requiring modification of existing systems will require discussions with the UW Signal Shop and the University’s Fire Protection Engineer.
    [Show full text]
  • NFS-3030/E Operations Manual
    Fire Alarm Control Panel NFS-3030/E Operations Manual Document 51344 11/4/03 Rev: C PN 51344:C ECN 03-419 Technical Manuals Online! - http://www.tech-man.com Fire Alarm System Limitations While a fire alarm system may lower insurance rates, it is not a substitute for fire insurance! An automatic fire alarm system—typically made up of Heat detectors do not sense particles of combustion and smoke detectors, heat detectors, manual pull stations, audible alarm only when heat on their sensors increases at a predeter- warning devices, and a fire alarm control panel with remote mined rate or reaches a predetermined level. Rate-of-rise notification capability—can provide early warning of a develop- heat detectors may be subject to reduced sensitivity over time. ing fire. Such a system, however, does not assure protection For this reason, the rate-of-rise feature of each detector against property damage or loss of life resulting from a fire. should be tested at least once per year by a qualified fire pro- The Manufacturer recommends that smoke and/or heat detec- tection specialist. Heat detectors are designed to protect tors be located throughout a protected premise following the property, not life. recommendations of the current edition of the National Fire IMPORTANT! Smoke detectors must be installed in the Protection Association Standard 72-1999 (NFPA 72-1999), same room as the control panel and in rooms used by the sys- manufacturer's recommendations, State and local codes, and tem for the connection of alarm transmission wiring, communi- the recommendations contained in the Guide for Proper Use of cations, signaling, and/or power.
    [Show full text]
  • MS-9600LS Intelligent Addressable Fire Alarm System
    MS-9600LS Intelligent Addressable Fire Alarm System Ideal for mid-sized to large facilities Sophisticated Performance on a Smaller Scale The MS-9600LS Fire Alarm System offers state-of-the-art technology with easy installation, operation, and maintenance. Suited for stand-alone appli- cations, the MS-9600LS is ideal for commercial, industrial, manufacturing, office buildings, schools, strip malls and other facilities requiring performance-based, sophisticated technology at reasonable cost. Based on the strong features found in the MS-9600, the new panel boasts a new higher speed communications protocol called LiteSpeed™. With standard support for 318 addressable Fire-Lite devices on one Signaling Line Circuit (SLC), the MS-9600LS can be expanded up to 636 devices with an optional second SLC board. The new communications protocol permits the use of standard 12AWG twisted unshielded fire wire and supports a maximum SLC distance of up to 10,000 feet from the panel. An optional high-speed communicator supports central station monitoring. With addressable point identification, drift compensation, and four NAC outputs with built-in synchronization, the MS-9600LS delivers features typically found only in more expensive, larger systems. High Performance with Remarkable Flexibility The panel supports a wide range of addressable sensors, control outputs, and notification devices capable of meeting the most challenging design specifications. With support for up to 159 modules and 159 detectors (318 total addressable points) on a single loop with expansion to a total of 636 devices with the second SLC board and a massive 7-amp switching power supply, the MS-9600LS provides ample room for expansion as your business needs grow.
    [Show full text]
  • SECTION 28 46 21.1X FIRE ALARM SYSTEMS
    American University Design Standards SECTION 28 46 21.1x FIRE ALARM SYSTEMS This document is provided as a reference for the design professionals working for American University (AU). This document should not be used directly as written project specifications. This document does not define products for maintenance replacement purposes, but rather should be used for renovation and new construction projects. The American University Facilities Management Life Safety Manager/Master Electrician has established standards for fire alarm systems to protect the AU community and buildings. While the standards reflect best business practice and represent industry standards, they are applied based on assessments of plans for newly constructed buildings and major renovations and take into account-planned uses of each facility and its occupants. These assessments and the application of these standards are intended to foster a uniform level of protection and notification associated with university structures, both within and exterior to the buildings. The standards, or variations of the standards, are applied based on recommendations to Facilities Management developed through the Life Safety Master Plan and in consultation with University Safety and Security (USSS) and the university insurance provider. The USSS Physical Security Unit also maintain lists of approved security hardware and will provide the information upon request. This hardware is standardized across campus and the physical security manager must approve variations from the list. All security and emergency notification system designs for new buildings and major renovations are prepared in partnership with the Planning and Project Management department. Application of these standards to existing buildings/locations on campus as of May 2016 will be at the joint direction of Facilities Management and University Safety and Security Services based on objectives in the current departmental Master Plans and a detailed risk and threat analysis.
    [Show full text]