PRODUCT AND SOLUTION GUIDE

+1.509.332.1890 [email protected] selinc.com Making Electric Power Safer, More Reliable, and More Economical 385-0080 2021 Technology Highlights

Example Popular Models for the SEL-2411P Pump Automation Controller

For a complete popular models listing, visit selinc.com/products/popular Select models typically ship in 2 days

Application Details Item No. Price Ultra-High-Speed Protection Capacitor Bank Control Advanced Generator Protection Meet the SEL-T401L Ultra-High-Speed Enhance your distribution system Provide advanced generator, bus, trans- Line Relay, which combines time-domain using the new SEL-734W Capacitor former, and auxiliary system protection Simplex, duplex, and triplex pump control for float switch level control 2411#GJ44 $2,130 USD technologies and high-performance Bank Control with wireless current for hydro, thermal, and pumped-storage and integration with SCADA. distance elements for a complete pro- sensors to improve power quality. applications with the new SEL-400G. tection and monitoring system.

Simplex, duplex, and triplex pump control for float switch level control 2411#BGCG $2,490 USD and/or analog level control and integration with SCADA.

Fault Transmitter and Receiver Synchrowave® Operations Time-Domain Link (TiDL®) Technology Apply the SEL-FT50 and SEL-FR12 Software Convert data using a TiDL merging unit and Simplex, duplex, and triplex pump control for float switch level control and/or analog level control, integration with SCADA, and ac voltage 2411#M9HF $2,700 USD Fault Transmitter and Receiver System Increase grid safety and reliability transport them via fiber to as many as four phase monitoring with diagnostic waveform event reports. to enhance distribution substation with situational awareness of power relays to achieve a simple, secure digital protection and improve the reliability system operations. secondary system solution. and safety of your feeder.

Redundant Power Module Software-Defined Networking powerMAX® Power Management Combine multiple ac and dc power Improve local-area networking with Intelligent control for seamless sources with the new SEL-RPM Redundant deny-by-default cybersecurity and islanding as well as comprehensive Power Module to increase control power fast failover. generation and load management availability and reliability. solutions.

On the Cover

The Tohono O’odham Utility Authority (TOUA) became the world’s first subtransmission utility to experience the SEL-T400L relay’s unprecedented tripping speed. In just over half an hour, the relay tripped seven times—in under 2 ms each time. Read the story of how TOUA made electric transmission protection history at selinc.com/featured-stories/TOUA.

“If not for this new technology, the power would have gone out and our crews would have been driving around and trying to restore it in bad weather. Instead, it did the job so well that we didn’t even know about the disturbance until later.”

—Darrold Hobbs, TOUA Electric Department Operations Manager © 2020 by Schweitzer Engineering Laboratories, Inc. All rights reserved. Table of Contents

SEL Overview Wireless Communications About SEL 2 Wireless Communications 32 Example Product Applications 6 Wireless Communications Features 33 Example Network Communications Diagram 8 Precise Time Generation Protection Precise Time 34 Generator and Motor Protection 10 Precise Time Features 35 Generator and Motor Protection Features 11 Transceivers and Adapters Transmission Protection Transceivers and Adapters 36 Transmission Protection 12 Transceivers and Adapters Features 37 Transmission Protection Features 13 Cables Substation Protection Cables 38 Substation Protection 14 Fiber-Optic Cable Features 39 Transformer Protection and Monitoring Features 15 Remote I/O Bus Protection Features 16 Remote I/O 40 Breaker Failure and Capacitor Bank 17 Protection Features Remote I/O Features 40

Distribution Protection Annunciation and Notification Distribution Protection 18 Annunciation and Notification 41 Distribution Protection Features 19 Annunciation and Notification Features 41

Distribution Control Accessories and Tools Accessories and Tools 42 Distribution Control 20 Distribution Control Features 21 Software Fault Indicators, Sensors, and CTs Software 43 Fault Indicators, Sensors, and CTs 22 Engineering Services Metering Engineering Services 44 Metering 24 Bookstore SEL-735 Power Quality Options 25 Bookstore 46

Automation SEL University Automation 26 SEL University 48 Automation Features 28 Ordering and Customer Support WAN and LAN Networks Ordering and Customer Support 50 WAN and LAN Networks 30 Popular Models WAN and LAN Networks Features 31 Popular Models Simplify Ordering 52

SCHWEITZER ENGINEERING LABORATORIES | 1 About SEL

Our mission—making electric power safer, more reliable, and more economical SEL invents, designs, manufactures, and supports a complete line of products and services for the protection, monitoring, control, automation, and metering of electric power systems. Our solutions range from comprehensive generator and transmission protection to distribution automation and control systems. SEL teams offer services, education, and support for a variety of industries and throughout the power system. Our Engineering Services team provides engineering expertise and system solutions to customers worldwide. SEL University offers training that helps our customers meet the technical challenges of integrating digital technologies into their expanding power system infrastructure.

Our history Edmund O. Schweitzer, III, founded SEL in 1982 in Pullman, Washington. SEL introduced the world’s first digital protective relay to the electric power industry in 1984 1984. The SEL-21 revolutionized the power protection S EL-21 industry by providing fault locating and real fault data at a much lower cost than traditional electromechanical relays. In 2016, we set the standard for technology with the introduction of the world’s fastest transmission line relay, the SEL-T400L Time-Domain Line Protection. And today we’ve introduced the SEL-T401L Ultra-High-Speed Today Line Relay that merges time-domain technology with S EL-T4 01L phasor-based protection in a single device. As part of a long-term strategy for sustained growth, stability, and customer focus, SEL became an employee- owned company in 1994 and transitioned to 100 percent employee ownership in 2009. Our ownership value is at the heart of our employees’ hard work to reduce costs, increase quality, and create the superior products that enable us to fulfill our mission.

2 | selinc.com | +1.509.332.1890 Industries we serve From the beginning, we’ve provided solutions for electric utilities. As our company has grown, so have our product portfolio and the number of industries we serve. From airports and hospitals to the power grids of entire countries, SEL solutions are protecting and controlling critical operations around the world.

▪ Electric power generation ▪ Power transmission and distribution ▪ Oil, gas, and petrochemical ▪ Renewable energy ▪ Metals and mining ▪ Water and wastewater ▪ Pulp and paper ▪ Mission-critical power systems ▪ Government ▪ Education and healthcare ▪ Consumer product manufacturing ▪ Transportation

SCHWEITZER ENGINEERING LABORATORIES | 3 Engineering is our middle name At SEL, we are passionate about our work, knowing it contributes directly to improving the reliability of electric power, keeping people safe, and helping customers conserve resources through efficiency, simplicity, and creativity. We develop innovative products and services by focusing on the challenges our customers face. This helps us create the best solutions for a wide range of industries and applications. Every day, SEL engineers create new technologies and solutions to solve our industry’s challenges.

Our commitment to quality Because SEL equipment becomes part of critical—and complex—infrastructure, from the electric power grid to “As engineers, we work every day processing and manufacturing facilities, we focus on long-term reliability and quality. to invent, design, and support products that monitor, control, and We warranty our products for 10 years and design them to last more than 20 years, and after serving our customers protect power systems installed for more than 30 years, we still don’t charge for repairs— all over the world. Serving our regardless of the age of the product. Our free repair industry is a tremendous privilege policy generates useful data that we use to drive product and responsibility that we take and service improvements. Constant improvement is an very seriously. Listening to our integral part of quality at SEL because of the lives and customers’ requirements and critical infrastructure our products protect. needs, we strive to make our solutions innovative, reliable, easy to use, and secure. We invest in our people, tools, and facilities in order to produce designs that exceed our customers’ requirements. Engineering is our middle name, and it’s what we love to do.”

—Dave Whitehead Chief Executive Officer

4 | selinc.com | +1.509.332.1890 Service and support you can count on We understand the importance of local support, which is why we have application engineers, customer service representatives, and sales managers in over 100 offices worldwide. Our network of independent “Society depends upon safe, sales representatives and distributors provides additional sales reliable, and economical electric support in many regions. This network of local experts supports SEL power. At SEL, we take our products and solutions in 165 countries, ensuring the best possible user experience. responsibility to this industry seriously. We strive to exceed SEL’s outstanding customer service and support reflect who we are. Our commitment to serving our industry is consistent with our values expectations with extraordinary and ethics. We believe strongly in our core company values, which are customer service, with expert not only an essential part of our working environment but also the way application engineers who are we view our community, industry, and the natural environment. always available to provide technical support close to our customers, and with sales engineers who solve problems by teaching and by adding value with SEL technology and innovation.”

—David Costello Chief Sales & Services Officer

SCHWEITZER ENGINEERING LABORATORIES | 5 Example Product Applications

Generators Distributed Generation (DG)

Comprehensive Generator Protection Intertie/Wind Generator Protection (S EL- 4 0 0 G , S EL-70 0 G ) (S EL-70 0 GT, S EL-70 0 GW )

Resistance Temperature Detection (S EL-26 0 0 ) DG Interconnection Recloser Control (S EL- 651R , S EL- 651R A ) Ground Fault Protection (S EL-266 4, S EL-266 4 S)

Transmission Lines Power Transformers

Time-Domain Line Protection Five-Winding Transformer Differential

(S EL-T4 0 0 L , S EL-T4 01L ) and Voltage Protection (SEL-487E)

Traveling-Wave Fault Location Four-Winding Transformer Differential (S EL-T4 0 0 L , S EL-T4 01L , S EL- 411L ) Protection (SEL-387)

Subcycle Line Differential Protection Three-Winding Transformer Differential (S EL-311L , S EL- 411L ) and Voltage Protection (SEL-387E)

Subcycle Distance Protection Two-, Three-, and Four-Winding (S EL- 421, S EL-311C) Transformer Differential and Voltage Protection (SEL-787, SEL-787-2/-3/-4)

Merging Unit With Built-In Distance Transformer Monitoring Protection (SEL-421) (S EL-2414)

Distribution Feeders Overhead and Underground Fault Distribution Protection Indication (SEL-AR360, SEL-AR, SEL-ARU, (S EL-351, S EL-351A , S EL-351S , S EL- 851) S EL-T PR , S EL- CR ) Protection, Automation, and Bay Control (SEL-451) Recloser Control (SEL-651R, SEL-651RA, SEL-351RS Kestrel®) Feeder Protection With Arc-Flash Detection (SEL-751, SEL-751A) Encrypted Wireless Communication (SEL-3031, SEL-3061) Voltage Regulator Control (SEL-2431) Compact Satellite-Synchronized Precise Time (SEL-2401)

Capacitor Bank Control Real-Time Automation Control (SEL-734B, SEL-734W and SEL-8340) (SEL-3505) Wireless Fault Detection and Load Fault Transmitter and Receiver System Monitoring (SEL-FLT and SEL-FLR, (S EL- F T50 a n d S EL- FR12) S EL- 8 3 01)

6 | selinc.com | +1.509.332.1890 Substations

Satellite-Synchronized Precise Time Rugged Computing (SEL-2401, SEL-2404, SEL-2407®, (SEL-3350, SEL-3355, SEL-3360) SEL-2488, SEL-3401) Wide-Area Communications Protection, Automation, and Bay (SEL ICON®) Control (SEL-451) Modular I/O and Real-Time Automation Low-Impedance Bus Differential Control (SEL-2240 Axion®) Protection (SEL-487B) Real-Time Automation Control Capacitor Protection and Control (SEL-3530/3530-4, SEL-3555, (S EL- 4 87 V ) SEL-3505/3505-3, SEL-3560) Cybersecurity High-Impedance Differential Protection (SEL-3620, SEL-3622) (SEL-587Z) Rugged Networking Power Quality and Revenue Metering (S EL-273 0 M , S EL-273 0 U, S EL-2725 , (SEL-735) S EL-274 0 S)

Programmable Automation Control Encrypted Wireless Communication (S EL-2411, S EL-24 4 0 ) (SEL-3031, SEL-3061) ® Serial Communication Annunciation and Notification (S EL-2924, S EL-2925) (S EL-2522, S EL-2523 , S EL-2533) High-Speed Remote I/O (S EL-2507 ) Merging Units With Built-In Protection (S EL- 4 01, S EL- 421) Fiber-Optic Communication (Fiber-Optic Transceivers) Digital Secondary System Protection Control Power Source Diversity and Control (TiDL®, SEL-TMU, SEL-401, (S EL- R PM ) SEL-421, SEL-451, SEL-487B, SEL-487E)

Industrial/Commercial

Motor Protection (SEL-710-5, SEL-849, Rugged Ethernet Networking motorMAX®) (S EL-274 0 S , S EL-2742S)

Power Quality and Revenue Metering Fast Motor Bus Transfer (SEL-735) (SEL-700BT, SEL-451)

Annunciation and Notification Industrial Automation and Computing (S EL-2522, S EL-2523 , S EL-2533) (SEL-3350, SEL-3355, SEL-3360)

Programmable Automation Control Modular I/O and Real-Time Automation (S EL-2411, S EL-2411P, S EL-24 4 0 ) Control (SEL-2240 Axion)

Feeder Protection With Arc-Flash Cybersecurity (SEL-3620, SEL-3622) Detection (SEL-751) Wireless Communications (SEL-3061)

SCHWEITZER ENGINEERING LABORATORIES | 7 Example Network Communications Diagram

O ce Environment Utility, Military, or Industrial Substation Distributed Control System Located in an Oce Environment Real-Time Automation Serial Shield® Controller (RTAC) SEL-651R SEL-3025 SEL-9192 SEL-9192 HMI SEL-3622 Security Gateway Distributed SEL-3555 Laptop or SEL-2814 Control Modem Modem GPS Clock SE SEL-9524 Smartphone SEL-2401 L- Encrypted 28 GNSS Antenna SEL-2925 ® PC Serial 00 Bluetooth Link Security Kit SEL-2488 SEL-3061 Cellular Router Integrated GPS Clock Remote SEL-3055 Communications Ethernet Access SEL-3045 Optical Network Security Gateway To SCADA SEL-3620 Manufacturing or SEL SEL-2516 Generating Plant ICON Software-De ned Remote I/O Module Network Switch Private SEL-3061 Network SEL-2740S SEL-3061 SEL Relays Cellular Router Link Type SEL-3025 Ethernet Serial Port Server Programmable Security Gateway SEL-2924 SEL-2814 SE Serial Fiber SEL-C805 Automation SEL-3610 L- Controller SEL SEL-3620 SEL-3530 SEL-2812 28 24 ICON Serial Fiber SEL-C808 SEL-2411 SEL-2533 SEL-2407 SEL Relays Serial Wired EIA-232 GPS Clock Automation IRIG-B Controller SEL-2812

SEL-387 SEL-2411 SEL-2800 SESEL-700G SESEL-L-71710-05 SEL-3555 Wired Ethernet SEL-651R Automation Controller SEL-3505 Fiber Backbone Switch Other IEDs SEL-587Z SEL-3555 Tough Ethernet SEL-2440 DPAC SEL-2600 SEL-2600 IRIG-B Fiber Ethernet Switch: SEL-2725, Distribution Module SEL-2730U, or Other IEDs SEL-2664 Discrete Programmable Wired EIA-485 SEL-2730M SEL-3400 Automation Controller Recloser Control With SEL-2440 DPAC SEL-3505 RTAC or SEL-3622 Transformer Other Wired Security Gateway Monitor SEL-2440 DPAC Encrypted Wireless SEL-2414 SEL-2411 Axion® Modular RTU/PLC Axion I/O EIA-485 to Fiber- Optic Transceiver Network SEL-2824 SEL-500 SEL-300 SEL-2240 Axion EtherCAT® SEL-2240 Axion Series Relays Series Relays SEL-700 Series Relays SEL Relays SEL Relays

SEL ICON SEL ICON

Engineering Control Operations Wide-Area Visualization System Con guration and Monitoring (Synchrophasors) and Device Management

Ethernet Security Gateway SEL-3620 Firewall Serial Shield SEL-3025

SEL-3355 SEL-3355 Automation Controller Automation Controller

SYNCHROWAVE® Event Synchrowave Operations ACSELERATOR QuickSet®

8 | selinc.com | +1.509.332.1890 O ce Environment Utility, Military, or Industrial Substation Distributed Control System Located in an Oce Environment Real-Time Automation Serial Shield® Controller (RTAC) SEL-651R SEL-3025 SEL-9192 SEL-9192 HMI SEL-3622 Security Gateway Distributed SEL-3555 Laptop or SEL-2814 Control Modem Modem GPS Clock SE SEL-9524 Smartphone SEL-2401 L- Encrypted 28 GNSS Antenna SEL-2925 ® PC Serial 00 Bluetooth Link Security Kit SEL-2488 SEL-3061 Cellular Router Integrated GPS Clock Remote SEL-3055 Communications Ethernet Access SEL-3045 Optical Network Security Gateway To SCADA SEL-3620 Manufacturing or SEL SEL-2516 Generating Plant ICON Software-De ned Remote I/O Module Network Switch Private SEL-3061 Network SEL-2740S SEL-3061 SEL Relays Cellular Router Link Type SEL-3025 Ethernet Serial Port Server Programmable Security Gateway SEL-2924 SEL-2814 SE Serial Fiber SEL-C805 Automation SEL-3610 L- Controller SEL SEL-3620 SEL-3530 SEL-2812 28 24 ICON Serial Fiber SEL-C808 SEL-2411 SEL-2533 SEL-2407 SEL Relays Serial Wired EIA-232 GPS Clock Automation IRIG-B Controller SEL-2812

SEL-387 SEL-2411 SEL-2800 SESEL-700G SESEL-L-71710-05 SEL-3555 Wired Ethernet SEL-651R Automation Controller SEL-3505 Fiber Backbone Switch Other IEDs SEL-587Z SEL-3555 Tough Ethernet SEL-2440 DPAC SEL-2600 SEL-2600 IRIG-B Fiber Ethernet Switch: SEL-2725, Distribution Module SEL-2730U, or Other IEDs SEL-2664 Discrete Programmable Wired EIA-485 SEL-2730M SEL-3400 Automation Controller Recloser Control With SEL-2440 DPAC SEL-3505 RTAC or SEL-3622 Transformer Other Wired Security Gateway Monitor SEL-2440 DPAC Encrypted Wireless SEL-2414 SEL-2411 Axion® Modular RTU/PLC Axion I/O EIA-485 to Fiber- Optic Transceiver Modbus Network SEL-2824 SEL-500 SEL-300 SEL-2240 Axion EtherCAT® SEL-2240 Axion Series Relays Series Relays SEL-700 Series Relays SEL Relays SEL Relays

SEL ICON SEL ICON

Engineering Control Operations Wide-Area Visualization System Con guration and Monitoring (Synchrophasors) and Device Management

Ethernet Security Gateway SEL-3620 Firewall Serial Shield SEL-3025

SEL-3355 SEL-3355 Automation Controller Automation Controller

SYNCHROWAVE® Event Synchrowave Operations ACSELERATOR QuickSet®

SCHWEITZER ENGINEERING LABORATORIES | 9 Generator and Motor Protection

SEL-400G NEW SEL-700G SEL-300G Provide unsurpassed protection, Provide utility and industrial Implement comprehensive primary integration, control, and monitoring generator protection with an and backup generator protection features for all types of generators, autosynchronizer, flexible I/O, for large and small machines. including hydropower, pumped- and advanced communications. storage hydropower, large steam turbines, and combustion gas turbines.

SEL-2664S SEL-2664 SEL-2600 Protect high-impedance grounded Combine the SEL-2664 with other Measure and transmit data from generators from ground faults at SEL generator protection devices up to 12 resistance temperature standstill, during startup, and to continuously monitor field-to- detector (RTD) inputs and one while running. ground resistance and protect contact input over a single fiber- critical components, including optic link. rotor and stator windings.

SEL-700BT NEW SEL-710-5 SEL-849 Ensure motor bus system process Provide protection, including optional Provide current-, voltage-, and continuity by allowing the quick arc-flash detection, for a full range thermal-based protection; arc-flash transfer of load to an auxiliary feeder of medium-voltage, three-phase detection; and power metering in during primary feeder line faults. induction, and synchronous motors. motor protection applications.

10 | selinc.com | +1.509.332.1890 Applications SEL-400G SEL-700G SEL-700GT SEL-700GW SEL-300G SEL-700BT SEL-710-5 SEL-849 Protection SEL-400G SEL-700G SEL-700GT SEL-700GW SEL-300G SEL-700BT SEL-710-5 SEL-849

Generator Protection ■ ■ + ■ ■ 21P Phase Mho or ■ + ■ Compensator Distance Induction Motor Protection ■ ■ 24 Overexcitation (Volts/Hertz) ■ ■ + ■ Synchronous Motor Protection + 27/59 Under-/Overvoltage ■ ■ ■ ■ ■ ■ + Motor Bus Transfer Protection ■ 27I/59I Inverse-Time Under-/ ■ ■ ■ ■ ■ Feeder Protection ■ ■ Overvoltage

Breaker Failure Protection ■ ■ ■ ƒ ■ ■ ■ 32 Directional Power ■ ■ ■ ■ +

Equipment Thermal Monitoring ■ ■ + + + ■ + ■ 37 Underpower ■ +

Generator Intertie Protection ■ 40 Loss of Field ■ ■ + ■

Synchronism Check ■ + ■ + ■ 46 Current Unbalance ■ ■ + ■ ■ ■ ■

Integrated Synchronizer + + + ■ 47 Phase Reversal ■ ■

49 Thermal ■ ■ + ■ ■ Instrumentation and Control 49R Thermal Overload (Resistance Temperature ■ ■ ■ ■ ■ ■ + Breaker Wear Monitor ■ ■ ■ ■ ■ ■ ■ Detector [RTD]) Demand Meter ■ ■ ■ ■ ■ ■ ■ ■ 50 (P,N,Q) Overcurrent (Phase, ■ ■ ■ ■ ■ ■ ■ ■ Load Profile Report ■ ■ ■ ■ ■ ■ ■ Neutral, Negative Sequence)

50Q Negative-Sequence RTD Inputs ■ + + + + + + ■ ■ ■ ■ ■ ■ ■ Overcurrent Ethernet + + + + + + ■ 51 (N,G) Time Overcurrent ■ ■ ■ ■ ■ ■ ■ ■ IEC 61850 Edition 2 + + + + + + + (Neutral, Ground)

IEC 60870-5-103 + + + + + 51 (P,Q) Time Overcurrent ■ ■ ■ ■ ■ ■ (Phase, Negative Sequence) Parallel Redundancy Protocol + + + + + + ■ (PRP) 55 Power Factor ƒ ƒ ƒ ■ +

DNP3 Serial ■ + + + + + + 60 Loss of Potential ■ ■ ■ ■ ■ ■ +

DNP3 LAN/WAN + + + + + + + 64G 100 Percent Stator Ground ■ + ■

Simple Network Time Protocol 64F Field Ground ■ ■ + ■ + + + + + + ■ (SNTP) 67 (N,G) Directional ■ ■ ■ ■ Built-In Web Server + + + + ■ + ■ Overcurrent (Neutral, Ground)

IEEE 1588 Precision Time 78 Out of Step ■ + ■ ■ + + + + + + Protocol (PTP) 81 Over-/Underfrequency ■ ■ ■ ■ ■ ■ + EtherNet/IP + + + + + + 87 Current Differential ■ + + + Modbus TCP + + + + + + + REF Restricted Earth Fault ■ ■ + Modbus RTU Outstation ■ ■ ■ + ■ ■ ■ Arc-Flash Detection + ■ Synchrophasors With IEEE ■ ■ ■ ■ C37.118 Protocol Separate Neutral Overcurrent ■ ■ ■ ■ ■ ■ ■

Mirrored Bits® Communications ■ ■ ■ ■ ■ ■ Broken Rotor Bar Detection ■

■ Standard feature + Model option ƒ May be created using settings

SCHWEITZER ENGINEERING LABORATORIES | 11 Transmission Protection

SEL-T400L SEL-T401L NEW SEL-T4287 Apply the SEL-T400L for ultra-high- Apply the SEL-T401L, which was Test traveling-wave fault speed protection of transmission built on the field experience of the locators and line protective lines. With breakthrough time-domain SEL‑T400L, for its unprecedented relays using the SEL-T4287, a technologies, the SEL-T400L trips in operating speed and complete simple-to-use, compact, and as fast as 1 ms, records events with suite of primary and backup line economical secondary pulse a 1 MHz sampling rate, and locates protection functions. Use injection test set. faults to the nearest tower. the SEL-T401L as a redundant protection system with other SEL relays without concerns for common-mode failures.

SEL-421 SEL-411L SEL-311C Employ the SEL-421 for high- Apply the SEL-411L for subcycle Apply the SEL-311C for three-pole speed distance and directional single- or three-pole line current distance protection, reclosing, protection and complete control differential, distance, and monitoring, and control of of a two-breaker bay. directional overcurrent protection. transmission lines. Traveling-wave fault locating pinpoints faults to the nearest tower span.

SEL-311L SEL-387L Use the SEL-311L with four-zone Use the SEL-387L for economical, distance backup for easy-to-apply, easy-to-apply line protection with high-speed line protection. zero settings.

12 | selinc.com | +1.509.332.1890 Instrumentation SEL-T400L SEL-T401L SEL-411L SEL-421 SEL-311C SEL-311L SEL-387L Applications SEL-T400L SEL-T401L SEL-411L SEL-421 SEL-311C SEL-311L SEL-387L and Control

Distance Protection ■ ■ ■ ■ ■ ■ 79 Automatic Reclosing ■ ■ ■ ■

Line Current Differential ■ ■ ■ Number of Controlled Breakers/ 2 2 2 2 1 1 1 CT Inputs Traveling-Wave Protection ■ ■ Fault Locating ■ ■ ■ ■ ■ ■ Breaker Failure Protection ■ ■ ■ ƒ Traveling-Wave Fault Locating ■ ■ + Undervoltage Load Shedding ƒ ƒ ƒ ƒ ƒ Subcycle Distance Elements ■ + + + Series-Compensated Lines ■ ■ + + SELogic® Control Equations ■ ■ ■ ■ ■

Protection Nonvolatile Latch Control Switches ■ ■ ■ ■ ■

21 (G,P,XG,XP) Distance (Mho SELogic Remote and Local Control ■ ■ ■ ■ ■ Ground, Mho Phase, Quad Ground, ■ ■ ■ ■ ■ Switches Quad Phase) Display Points ■ ■ + ■ 25 Synchronism Check ■ ■ ■ ■ Mirrored Bits® Communications ■ ■ ■ ■ ■ ■ 27/59 Under-/Overvoltage ■ ■ ■ ■ ■ Substation Battery Monitor ■ ■ ■ ■ ■ 32 Directional Power ■ ■ Breaker Wear Monitor ■ ■ ■ ■ 49 Thermal ƒ ƒ Trip Coil Monitor ƒ ƒ ƒ ƒ 50 (N,G,P,Q) Overcurrent (Neutral, ■ ■ ■ ■ ■ Event Report (Multicycle Data) and Ground, Phase, Negative Sequence) ■ ■ ■ ■ ■ ■ ■ Sequential Events Recorder 51 (N,G,P,Q) Time Overcurrent (Neutral, ■ ■ ■ ■ ■ Ground, Phase, Negative Sequence) 1 MHz Event Reports ■ ■

67 (N,G,P,Q) Directional Overcurrent Instantaneous Metering ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ (Neutral, Ground, Phase, Neg. Seq.) Software-Invertible Polarities ■ ■

81 Under-/Overfrequency ■ ■ ■ ■ IEC 60255-Compliant Thermal Model ■ ■

87L Line Current Differential ■ ■ ■ DNP3 Level 2 Outstation ■ ■ ■ ■ ■ + +

Programmable Analog Math ■ ■ Parallel Redundancy Protocol (PRP) ■ ■ ■

Out-of-Step Block and Trip ■ ■ ■ ■ ■ IEEE 1588 + + Load Encroachment Supervision ■ ■ ■ ■ ■ Version 2 (PTPv2)

Switch-Onto-Fault ■ ■ ■ ■ ■ IEEE C37.94 Protocol ■ + + IEC 61850-9-2 Sampled Values Single-Pole Trip ■ ■ ■ ■ + + + Technology TD21 Incremental-Quantity Distance ■ ■ Time-Domain Link (TiDL®) Technology + TD32 Incremental-Quantity Directional ■ ■ IEC 61850 Communications + + + + TW32 Traveling-Wave Directional ■ ■ Synchrophasors ■ ■ ■ ■ TW87 Traveling-Wave Differential ■ ■ Built-In Current and Voltage ■ ■ Zone/Level Timers ■ ■ ■ ■ ■ Playback Capability

Pilot Protection Logic ■ ■ ■ ■ ■ ■ SEL Fast Time-Domain Values ■ ■

Miscellaneous

Accepts Delta Voltage Transformers + for Protection

Configurable Labels ■ ■ ■ ■ +

■ Standard feature + Model option ƒ May be created using settings

SCHWEITZER ENGINEERING LABORATORIES | 13 Substation Protection

SEL-787-2/-3/-4 SEL-TMU NEW SEL-401 Apply advanced protection Employ the SEL-TMU for remote Apply the SEL-401 in substations and monitoring with flexible data acquisition in substations with IEC 61850-9-2 Sampled communications to two-, with Time-Domain Link (TiDL®) Values (SV) systems. The SEL-401 three-, and four-terminal technology systems. It can share is a standalone merging unit with transformers. data with up to four TiDL relays. phase overcurrent and breaker failure protection.

SEL-487V SEL-487E SEL-2414 Protect and control grounded Provide high-speed transformer Provide complete system and ungrounded, single- and differential protection for up to monitoring and control for new double-wye capacitor bank five terminals as well as advanced and existing transformers. configurations. monitoring, metering, automation, and control.

SEL-487B SEL-587Z SEL-352 Provide bus differential and Use the economical SEL-587Z to Provide breaker failure protection breaker failure protection, combine proven high-impedance and breaker control and monitoring automation, and control in analog technology with the with unparalleled flexibility. applications with up to seven advantages of microprocessor terminals per relay. technology.

14 | selinc.com | +1.509.332.1890 Transformer Protection and Monitoring

Instrumentation SEL-487E SEL-387E SEL-387 SEL-387A SEL-787 SEL-787-2X/-21/-2E SEL-787-3E/-3S/-4X SEL-587 SEL-2414 Applications SEL-487E SEL-387E SEL-387 SEL-387A SEL-787 SEL-787-2X/-21/-2E SEL-787-3E/-3S/-4X SEL-587 SEL-2414 and Control

Breaker Failure Protection ■ ƒ ƒ ƒ ■ ■ ■ ƒ ƒ SELogic® Control Equations ■ ■ ■ ■ ■ ■ ■ ■ ■

Transformer and Machine Current Voltage Check on Closing ƒ ƒ ƒ ƒ ƒ ■ ■ ■ ■ ■ ■ ■ ■ Differential Transformer Cooling Fan Control ƒ ƒ ƒ ƒ ■ Low-Impedance Bus Differential ■ ■ ■ ■ Nonvolatile Latch Control ■ ■ ■ ■ ■ ■ ■ ■ Underfrequency Load Shedding ■ ƒ + + + Switches

Undervoltage Load Shedding ■ ƒ + + + SELogic Remote Control Switches ■ ■ ■ ■ ■ ■ ■ ■ ■

3 SELogic Local Control Switches ■ ■ ■ ■ ■ ■ ■ ■ + + Three-Phase Current Inputs 5 3 4 2 2 2 or 2 3 4 Display Points ■ ■ ■ ■ ■ ■ ■ ■

+ + + + Three-Phase Voltage Inputs 2 1 1 1 1 1 Multiple Settings Groups ■ ■ ■ ■ ■ ■ ■

Substation Battery Monitor ■ ■ ■ ■ + + ƒ Protection Breaker Wear Monitor ■ ■ ■ ■ ■ ■ 24 Overexcitation (Volts/Hertz) ■ ■ + + + Event Report (Multicycle Data) ■ ■ ■ ■ ■ ■ ■ ■ ■ 25 Synchronism Check ■ + Sequential Events Recorder ■ ■ ■ ■ ■ ■ ■ ■ 27/59 Under-/Overvoltage ■ ■ + + + Instantaneous and Demand Meter ■ ■ ■ ■ ■ ■ ■ ■ ■ 32 Directional Power ■ + + + Load and Temperature Profile ■ ■ ■ ■ ■ 46 Current Unbalance ■ Report

49 Equipment Thermal Monitoring ■ + ■ ■ ■ ■ RTD (Resistance Temperature + + + + Detector) Inputs 50FO Flashover Protection ƒ ƒ ƒ ƒ ƒ Built-In Web Server ■ ■ + + 50 (N,G) Overcurrent (Neutral, ■ ■ ■ ■ ■ ■ ■ ■ Ground) Software-Invertible Polarities ■

50P Phase Overcurrent, 50Q IEC 60255-Compliant Thermal ■ ■ ■ ■ ■ ■ ■ ■ ■ Negative-Sequence Overcurrent Model

51 (N,G) Time Overcurrent (Neutral, IEEE C37.118 Synchrophasors ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ground) IEC 61850 + + + + + + 51P Phase Time Overcurrent ■ ■ ■ ■ ■ ■ ■ ■ IEC 61850-9-2 Sampled Values + 51Q Negative-Sequence Time Technology ■ ■ ■ ■ ■ ■ ■ ■ Overcurrent Simple Network Time Protocol ■ + + + 67 (P,G,Q) Directional Overcurrent (SNTP) (Phase, Ground, Negative ■ Parallel Redundancy Protocol Sequence) ■ + + + (PRP) 81 Under-/Overfrequency ■ ■ + + + IEEE 1588 Precision Time Protocol + + + 81R Rate-of-Change of Frequency ƒ Version 2 (PTPv2)

87 Current Differential ■ ■ ■ ■ ■ ■ ■ ■ EtherNet/IP + +

REF Restricted Earth Fault ■ ■ ■ + + + ■ Time-Domain Link (TiDL®) + Technology

Through-Fault Monitor ■ ■ + ■ ■ ■ ■ ■

Thermal Model/SEL-2600 RTD ■ + ■ ■ ■ ■ ■ Module Communications

■ Standard feature + Model option ƒ May be created using relay elements, device word bits, analog quantities, and timers

SCHWEITZER ENGINEERING LABORATORIES | 15 Bus Protection

Instrumentation SEL-387 SEL-487B SEL-487E SEL-587Z Applications and Control SEL-387 SEL-487B SEL-487E SEL-587Z

Breaker Failure Protection ƒ ■ ■ ƒ 79 Automatic Reclosing ƒ ƒ

Bus Differential ƒ ■ ■ ■ Dynamic Zone Selection ■

Transformer and Machine Current SELogic® Control Equations ■ ■ ■ ■ ■ ■ Differential Nonvolatile Latch Control Switches ■ ■ ■ High-Impedance Bus Differential ■ SELogic Remote/Local Control ■ ■ ■ ■ Low-Impedance Bus Differential ■ ■ ■ Switches

‡ Three-Phase Current Inputs 4 7/10/21 5 Common Display Points ■ ■ ■ ■

Three-Phase Voltage Inputs 1 2 Multiple Settings Groups ■ ■ ■

Substation Battery Monitor ■ ■ ■ Protection Breaker Wear Monitor ■ ■ 27/59 Under-/Overvoltage ■ ■ Event Report (Multicycle Data) ■ ■ ■ ■ 46 Current Unbalance ƒ ■ Sequential Events Recorder ■ ■ ■ ■ 47 Voltage Unbalance ƒ Instantaneous Meter ■ ■ ■ ■ 50 (N,G) Overcurrent (Neutral, ■ ■ ■ Ground) Demand Meter ■ ■ ■

50P Phase Overcurrent ■ ■ ■ ■ Through-Fault Monitor ■ ■

50Q Negative-Sequence Software-Invertible Polarities ■ ■ ■ ■ Overcurrent IEC 60255-Compliant Thermal Model ■ 51 (N,G) Time Overcurrent (Neutral, ■ ■ ■ IEEE C37.118 Synchrophasors ■ Ground) Synchrophasor Real-Time Control ■ 51P Phase Time Overcurrent ■ ■ ■ ■ IEC 61850 + + 51Q Negative-Sequence Time ■ ■ ■ Overcurrent IEC 61850-9-2 Sampled Values + + Technology 87 Current Differential ■ ■ ■ Built-In Web Server ■ ■ 87Z High-Impedance Differential ■ Simple Network Time Protocol Single-Pole Trip/Close ■ ■ ■ (SNTP) ‡ Three-Phase Differential Bus Zones 1 2/3/6 1 1 Mirrored Bits® Communications ■ ■ Check Zones 3 Parallel Redundancy Protocol (PRP) ■ ■

IEEE 1588 Precision Time Protocol + + Version 2 (PTPv2)

Time-Domain Link (TiDL®) + + Technology

Miscellaneous Features

Connectorized® (Quick Disconnect) + + + Available

‡ ■ Standard feature + Model option 1/2/3 relay application ƒ May be created using settings

16 | selinc.com | +1.509.332.1890 Breaker Failure and Capacitor Bank Protection

Instrumentation Applications SEL-352 SEL-451 SEL-487B SEL-487V and Control SEL-352 SEL-451 SEL-487B SEL-487V

Breaker Failure Protection, Number of Open-Pole Detection ƒ ƒ ■ 1 2 7 1 Three-Phase Breakers 79 Automatic Reclosing ƒ ■ ƒ ƒ Bus Differential ■ SELogic® Control Equations ■ ■ ■ ■ Shunt Capacitor Bank Protection ƒ ■ Voltage Check on Closing ■ Underfrequency Load Shedding ƒ ƒ Nonvolatile Latch Control Switches ■ ■ ■ ■ Undervoltage Load Shedding ƒ ƒ ƒ ƒ SELogic Remote/Local Control Switches ■ ■ ■ ■

Protection Display Points ■ ■ ■ ■

25 Synchronism Check ■ ■ Multiple Settings Groups ■ ■ ■ ■

27/59 Under-/Overvoltage ■ ■ ■ ■ Substation Battery Monitor + ■ ■ ■

32/37 Power Elements ■ ƒ ƒ ■ Breaker Wear Monitor + ■ ■ Voltage Sag, Swell, and Interruption 46 Current Unbalance ■ ƒ ƒ ■ ■ ■ (VSSI) Recording 47 Voltage Unbalance ƒ ƒ ƒ Event Report (Multicycle Data) ■ ■ ■ ■ 49 Equipment Thermal Monitoring + ƒ ƒ Sequential Events Recorder ■ ■ ■ ■ 50FO Flashover Protection ■ ■ ■ Instantaneous Meter ■ ■ ■ ■ 50 (N,G) Overcurrent (Neutral, Ground) ■ ■ ■ Demand Meter ■ ■ 50P Phase Overcurrent ■ ■ ■ ■ Harmonic Metering ■ 50Q Negative-Sequence Time ■ ■ Overcurrent Software-Invertible Polarities ■

51 (N,G) Time Overcurrent (Neutral, IEC 60255-Compliant Thermal Model ■ ■ ■ Ground) IEEE C37.118 Synchrophasors ■ ■ 51P Phase Time Overcurrent ■ ■ ■ IEC 61850 + + + 51Q Negative-Sequence Time ■ ■ IEC 61850-9-2 Sampled Values Overcurrent + + Technology 60 (N,P) Current Unbalance (Neutral, ■ Built-In Web Server ■ ■ ■ Phase) Simple Network Time Protocol (SNTP) ■ ■ ■ 67 Directional Overcurrent ■ ■ Parallel Redundancy Protocol (PRP) ■ ■ ■ 81 Under-/Overfrequency ■ ■ IEEE 1588 Precision Time Protocol 81R Rate-of-Change of Frequency ■ + + Version 2 (PTPv2) 87 Current Differential ■ Time-Domain Link (TiDL®) Technology + + 87V Voltage Differential ■ ƒ ■ SEL-2600 RTD Module Communications + ■ ■ Single-Pole Trip/Close ■ ■ Miscellaneous Features

Connectorized® (Quick Disconnect) + + + + Available

Synchrophasor Real-Time Control ■ ■ ‡ ■ Standard feature + Model option 1/2/3 relay application ƒ May be created using settings ■ Standard feature + Model option ƒ May be created using relay elements and timers

SCHWEITZER ENGINEERING LABORATORIES | 17 Distribution Protection

SEL-851 NEW SEL-751 SEL-451 A compact relay for utility Ideal for industrial and utility Flexible overcurrent protection and industrial applications feeder protection, offering an with complete substation bay that provides powerful feeder intuitive color touchscreen, control. protection, monitoring, and fast and secure arc-flash control as well as fast and detection, flexible I/O, and secure arc-flash detection. advanced communications.

SEL-351 SEL-351A SEL-351S Transmission or distribution An economical solution Comprehensive feeder and overcurrent protection, for distribution feeder overcurrent protection perfect monitoring, and control. protection. for industrial and utility feeder applications.

SEL-501 SEL-551/551C Two complete and independent Distribution protection and groups of protection in one control in new and retrofit low-cost unit for feeders, installations. buses, transformers, motors, and breakers.

18 | selinc.com | +1.509.332.1890 Instrumentation SEL-451 SEL-351 SEL-351A SEL-351S SEL-851 SEL-751 SEL-751A SEL-501/501-2 SEL-551/551C Applications SEL-451 SEL-351 SEL-351A SEL-351S SEL-851 SEL-751 SEL-751A SEL-501/501-2 SEL-551/551C and Control

Distribution Feeder Protection ■ ■ ■ ■ ■ ■ ■ ■ ■ 79 Automatic Reclosing ■ ■ ■ ■ ■ + + ■

Breaker Failure Protection ■ ■ ƒ ■ ■ ■ ■ + ƒ Fault Locating ■ ■ ■ ■ +

Generator Intertie Protection ■ ■ ■ ■ + + SELogic® Control Equations With ■ ■ ■ ■ ■ ■ ■ ■ Remote Control Switches Synchronism Check ■ ■ ■ ■ + + SELogic Counters ■ ■ ■ ■ Underfrequency Load Shedding ƒ ■ ■ ■ ■ ■ ■ Voltage Check on Closing ■ ■ ■ ■ + + Undervoltage Load Shedding ƒ ■ ■ ■ + + + SELogic Nonvolatile Latch ■ ■ ■ ■ ■ ■ ■ +

Protection Nonvolatile Local Control ■ ■ + ■ ■ ■ ■ Switches 27/59 Under-/Overvoltage ■ ■ ■ ■ + + + Substation Battery Monitor ■ ■ ■ ■ + + 32 Directional Power Elements ■ + + + + + Breaker/Recloser Wear Monitor ■ ■ ■ ■ ■ ■ ■ 49 IEC Line/Cable Thermal ƒ ■ Overload Trip Coil Monitor ƒ ƒ ƒ ƒ ƒ ƒ ƒ

50 (P,N,G,Q) Overcurrent Element Voltage Sag, Swell, and ■ + + (Phase, Neutral, Ground, Negative ■ ■ ■ ■ ■ ■ ■ ■ ■ Interruption (VSSI) Sequence) Load/Signal Profile Recorder ■ + + ■ ■ ■ 51 (P,N,G,Q) Time Overcurrent Element (Phase, Neutral, Ground, ■ ■ ■ ■ ■ ■ ■ ■ ■ Sequential Events Recorder ■ ■ ■ ■ ■ ■ ■ ■ Negative Sequence) Software-Invertible Polarities ■ 67 (P,N,Q) Directional Overcurrent IEC 60255-Compliant Thermal (Phase, Neutral, Negative ■ ■ ■ ■ + ■ Model Sequence) DNP3 Level 2 Outstation ■ ■ ■ ■ + + + 78VS Vector Shift + Parallel Redundancy Protocol 81 Over-/Underfrequency ■ ■ ■ ■ + ■ + + ■ ■ ■ + (PRP) Separate Neutral Overcurrent ■ ■ ■ ■ ■ ■ ■ ■ IEEE 1588 Precision Time Protocol + + Load Encroachment Supervision ■ ■ ■ ■ ■ Version 2 (PTPv2)

Low-Energy Analog (LEA) Time-Domain Link (TiDL®) + + + Voltage Inputs Technology

Directional Sensitive Earth Fault IEEE C37.118 Synchrophasors ■ ■ ■ ■ ■ ■ + + + + Protection Bay Control ■ + Pilot Protection Logic ■ ■ ■ Ethernet + ■ ■ ■ + + + Rate-of-Change of Frequency ■ ■ ■ ■ + + EtherNet/IP + (df/dt) IEC 61850 + + + + + + + Harmonic Blocking ■ ■ + ■ ■ ■ IEC 61850 Edition 2 + + + Arc Sense™ Technology (AST) + + High-Impedance Fault Detection IEC 61850-9-2 Sampled Values + Technology Arc-Flash Detection + + + Simple Network Time Protocol Phantom Phase Voltage ■ ■ ■ ■ ■ ■ ■ + + + (SNTP) 4/3 4/0 Current/Voltage Channels 6/6 4/4 4/4 4/4 4/3 6/0 4/0 Harmonic Metering ■ ■ ■ ■ 4/5+ 4/5+ RMS Metering ■ ■ ■ ■ ■ ■ ■ Complete Two-Breaker Control ■ ■

■ Standard feature + Model option ƒ May be created using settings

SCHWEITZER ENGINEERING LABORATORIES | 19 Distribution Control

SEL-FT50 and SEL-FR12 SEL-651R SEL-651RA The SEL-FT50 and SEL-FR12 system The SEL-651R provides Automatic The SEL-651RA is a powerful, improves distribution protection by Network Reconfiguration, three- cost-effective, and flexible providing fault indication in 6 ms, phase and single-phase tripping, recloser control for 14-pin allowing relays and recloser controls and other distribution automation applications. It is compatible to make better tripping decisions. solutions. It is compatible with with popular reclosers. popular reclosers.

SEL-351RS Kestrel® SEL-734B SEL-734W The SEL-351RS provides integrated The SEL-734B includes low-energy The enhanced SEL-734W and logic and communications and analog inputs and provides advanced SEL-8340 Wireless Current comprehensive protection for monitoring and control capabilities Sensor solution provides single-phase applications. for applications such as capacitor advanced capacitor bank control bank control and feeder monitoring. to improve power quality.

SEL-2431 The SEL-2431 optimizes system voltages by using directional voltage profiles and detailed tap change event reports.

20 | selinc.com | +1.509.332.1890 Instrumentation SEL-351RS SEL-651RA SEL-651R Applications SEL-351RS SEL-651RA SEL-651R and Control

Distribution Feeder Protection ■ ■ ■ 79 Automatic Reclosing ■ ■ ■

Breaker Failure Protection ƒ ƒ ƒ Fault Locating ■ + ■

Generator Intertie Protection ■ ■ SELogic® Control Equations With Remote ■ ■ ■ Control Switches Synchronism Check + ■ SELogic Counters ■ ■ ■ Underfrequency Load Shedding ■ ■ ■ Voltage Check on Closing ■ ■ ■ Undervoltage Load Shedding ■ ■ ■ SELogic Nonvolatile Latch ■ ■ ■

Protection Nonvolatile Local Control Switches ■ ■ ■

25 (G,T) Generator/Intertie Synchronism Check ■ ■ Breaker/Recloser Wear Monitor ■ ■ ■

27/59 Under-/Overvoltage ■ ■ ■ Trip Coil Monitor ƒ ƒ ƒ

32 Directional Power Elements ■ + ■ Voltage Sag, Swell, and Interruption (VSSI) ■ + ■

50 (P,N,G,Q) Overcurrent Element (Phase, Neutral, Load/Signal Profile Recorder ■ ■ ■ ■ ■ ■ Ground, Negative Sequence) Sequential Events Recorder ■ ■ ■ 51 (P,N,G,Q) Time-Overcurrent Element (Phase, ■ ■ ■ DNP3 Level 2 Outstation ■ ■ ■ Neutral, Ground, Negative Sequence) IEEE C37.118 Synchrophasors ■ ■ ■ 67 (P,N,Q) Directional Overcurrent (Phase, Neutral, ■ ■ Negative Sequence) Ethernet ■ ■ ■

78VS Vector Shift ■ ■ IEC 61850 + + +

81 Over-/Underfrequency ■ ■ ■ Simple Network Time Protocol (SNTP) ■ ■ ■

Separate Neutral Overcurrent ■ ■ Harmonic Metering ■ ■ ■

Load Encroachment Supervision ■ ■ RMS Metering ■ ■ ■ Low-Energy Analog (LEA) Voltage Inputs + + ■ Standard feature + Model option ƒ May be created using settings Directional Sensitive Earth Fault Protection ■ ■

Pilot Protection Logic ƒ ƒ

Rate-of-Change of Frequency (df/dt) ■ ■ ■

Fast Rate-of-Change of Frequency ■ ■

Harmonic Blocking ■ ■ ■

Arc Sense™ Technology (AST) High-Impedance + + Fault Detection

Phantom Phase Voltage ■ ■ ■

4/1 Current/Voltage Channels 1/1 4/6 4/6+

SCHWEITZER ENGINEERING LABORATORIES | 21 Fault Indicators, Sensors, and CTs

SEL-FLT and SEL-FLR SEL-AR360 and SEL-AR SEL-ER Improve distribution reliability with the Locate momentary and permanent Provide maintenance-free fault SEL-FLT and SEL-FLR system, which faults in overhead applications. The indication with a battery-free design enables faster fault locating, reduces SEL-AR360 and SEL-AR automatically and automatic voltage reset. outage durations, and improves the adjust their trip thresholds to average restoration time. coordinate with the load current in distribution systems up to 69 kV.

SEL-BTRIP RadioRANGER® SEL-8301 Locate momentary and permanent Reduce the need to access vaults Optimize outage management faults in overhead applications. or open pad-mounted enclosures and improve underground system The SEL-BTRIP provides four field- to retrieve the fault indicator status, reliability. selectable trip thresholds so you decreasing fault-locating time and can stock one fault indicator for improving safety. multiple applications.

SEL-ARU SEL-TPR SEL-CR Use the Dynamic Delayed Trip Easily install the SEL-TPR on most Monitor underground systems feature to improve coordination brands of 200 A or 600 A elbows with the SEL-CR, which is powered with upstream protection, with capacitive test points. It is ideal by the load current present on an maximizing reliable performance. for pad-mounted transformer and energized line. switchgear applications.

22 | selinc.com | +1.509.332.1890 SEL-SR SEL-TR SEL-MW Apply the SEL-SR to pad-mounted Indicate both momentary and Use the SEL-MW in place of PTs to transformers when there is insufficient permanent faults in underground detect system voltage loss where primary current to power and reset distribution systems with low exact system voltage measurement current-powered fault indicators. load and low voltage. reporting is not required. The SEL-MW indicates voltage loss via a contact output.

SEL-PILC SEL-GFD SEL-MR Apply the SEL-PILC on paper- Apply the SEL-GFD over a three- Troubleshoot overhead and insulated lead-covered cables. phase cable bundle at ground underground applications up It features a rugged design and potential in switch-gear to identify to 38 kV with this portable, can be submerged in up to faults on circuits feeding medical fault-powered manual reset 15 feet of water. facilities, mining equipment, and fault indicator. other industrial equipment.

SEL-VIN SEL-CT SEL-SCT Easily install SEL-VINs on the test point Economically add SEL CTs to Easily add the SEL-SCT in of a 200 A elbow, 600 A T-body, or 600 A existing wiring and electrical subsurface vaults where flooding basic insulating plug. The line-powered equipment without interrupting can occur. The separable-core SEL-VIN indicates the presence of service. design allows the SEL-SCT to voltage at or above 2 kV (phase to be opened and installed without ground) by flashing a neon lamp. interrupting the connection. SCHWEITZER ENGINEERING LABORATORIES | 23 Metering

SEL-735 Power Quality and Revenue Meter Meter Installation Options and Accessories Achieve high-accuracy revenue and power quality Mount SEL meters and accessory devices into a metering for any application. The SEL-735 offers 1 GB variety of locations using a complete line of mounting of recording memory for up to 20 years of storage kits. You can choose from rack-mount, wall-mount, and is now available with a color touchscreen display. indoor, or outdoor configurations. If you have an Multiple enclosure and mounting options are available. existing panel cutout, you can retrofit your meter using our retrofit bezels. For more information, visit selinc.com/products/73x/meter-options.

ACSELERATOR Database API

® Enterprise TEAM Software

ACSELERATOR TEAM® and Enterprise Billing, OMS, ACSELERATOR® Database Database EMS, PQ

acSELerator® Meter Reports acSELerator Database API Transform metering data into action with Allow third-party systems to access acSELerator acSELerator Meter Reports SEL-5630 Team® SEL-5045 Software data with the SEL-5230 Software. The software offers interactive acSELerator Database API. This allows different charts, fast database interrogation, and the enterprise-level systems, such as an energy ability to customize metering reports for management system or a billing system, to utilities, industrial operations, and site-wide integrate data reporting. ACSELERATOR TEAM® and ACSELERATOR Meter campus monitoring. ACSELERATOR® Database Reports Software Serial/Ethernet Connection TEAM®

SEL-735 SEL-734 SEL Relay SEL Meters

Enterprise Software

ACSELERATOR Enterprise Billing, OMS, Database API Database EMS, PQ 24 | selinc.com | +1.509.332.1890 Customer-Supplied Components SEL-735 Power Quality Options

General Basic Intermediate Advanced

Customizable three-line or single- Display Customizable three-line or Customizable three-line or line display; 5-inch, 800 × 480 single-line display single-line display color touchscreen display*

Type-C USB Front Port No No Yes*

Memory 128 MB 256 MB 1 GB

Maximum Harmonic Order 15th 63rd 63rd

Interharmonic Quantities No No Yes

Harmonic Angles No No Yes

Power Harmonics No No Yes

Portable Case No No Yes*

Waveform Capture

Samples Per Cycle 16 16, 128 16, 128, 512

Duration (Cycles) 15 15–600 15–600

Number of Events 256 33–6,200 101–10,000

COMTRADE Reports Yes Yes Yes

Wave View Oscillography No No Yes

Load Profile Data

Recorders × Channels 1 × 16 12 × 16 32 × 16

Acquisition Rates 1–120 min 3–59 s, 1–120 min 3–59 s, 1–120 min

Storage Duration for 10-Minute Interval Data

16 Channels 10 years 20 years 20 years

192 Channels N/A 1.5 years 9.5 years

512 Channels N/A N/A 3.5 years

Voltage Sag, Swell, and Interruption (VSSI) Recorder

Typical Number of Summary Events 260 260 600

Number of Detailed Rows 60,000 60,000 130,000

Minimum Disturbance Duration 1/4 cycle 1/4 cycle 1/4 cycle

4 samples/cycle–1 sample/day, 4 samples/cycle–1 sample/day, 4 samples/cycle–1 sample/day, Sampling Rate adaptive adaptive adaptive

Sequential Events Recorder (SER) � � � Number of Events 80,000 80,000 80,000

Number of Channels Monitored ≤72 ≤72 ≤72

IEC 61000-4-30 Power Quality Compliance

150/180-Cycle, 10-Minute, 2-Hour Aggregation – Class A Class A

Class A (1 min, 10 min, Flicker – Class A (10 min, 2 hr updates) 2 hr updates)

Voltage Harmonics Class A Class A Class A

Harmonic Currents Class A Class A Class A

*Optional feature SCHWEITZER ENGINEERING LABORATORIES | 25 Automation

SEL-3355 SEL-3360S/3360E SEL-3350 NEW The SEL-3355 is a server-class The SEL-3360S and SEL-3360E The SEL-3350 is ideal for limited- automation controller built to match the performance, space, dedicated embedded with-stand harsh environments in ruggedness, and configuration applications that require midlevel utility substations and industrial flexibility of the SEL-3355 and I/O and computation. It can control and automation systems. are ideal for surface- or panel- be configured as an RTAC, as It can be configured as an RTAC, mount applications. a computer, or with the SEL as a computer, or with the SEL BlueFrame application platform. BlueFrame™ application platform.

SEL-3390 SEL-9331 SEL BlueFrame NEW SEL PCIe expansion cards let The SEL-9331 powers equipment Scalable and flexible, SEL BlueFrame you add ports and connectivity in industrial environments where provides a secure platform for to various industrial automation many power supplies cannot installing applications and for platforms. maintain operation. managing and exchanging data between supported applications, like SEL Data Management and Automation applications.

26 | selinc.com | +1.509.332.1890 SEL-3555 RTAC SEL-3560E/3560S RTACs SEL-3530/3530-4 RTACs Powerful processing for large- Powerful processing for large- Complete and flexible system scale automation projects. scale automation projects in a control with integrated security, compact form factor. seamless configuration, unified logic, and high reliability.

SEL-3505/3505-3 RTACs SEL-2240 Axion® SEL-2411P Powerful automation, reporting, A fully integrated, modular I/O Hardened, SCADA-ready and control for low-power, and control solution for utility pump automation controller limited-space applications. and industrial applications. with flexible I/O that is easy to install, set, and customize.

SEL-2411 SEL-2440 Flexible I/O for automatic Utility-grade I/O, powerful control, SCADA, station processing, flexible integration, remote monitoring, communications, and and plant control systems. microsecond timing.

SCHWEITZER ENGINEERING LABORATORIES | 27 SEL-3355 SEL-3360E SEL-3360S SEL-3350 Applications SEL-3355 SEL-3360E SEL-3360S SEL-3350 Hardware (Continued)

Computing in Harsh Environments ■ ■ ■ ■ 4 Rear and 2 Front USB Ports, USB 3.1-Compliant, 2.0 A ■ ■ ■ Max. Current Limit Each Running Multiple Applications Simultaneously ■ ■ ■ ■ 4 Rear USB 2.0 Ports and 2 Front USB 3.1 Ports, 1.5 A Installing Third-Party Software ■ ■ ■ ■ Combined Current on Front Ports, 1.5 A Combined ■ Embedding Into Automation and Monitoring Systems ■ ■ ■ ■ Current on Rear Ports Front 10/100/1000 Mbps Independent Copper HMI ■ ■ ■ ■ ■ Ethernet Ports Security Gateway to Help Satisfy NERC CIP Requirements ■ ■ ■ ■ Rear 10/100/1000 Mbps Independent Ethernet Ports 2 2 2 Network Monitoring and Intrusion Detection ■ ■ ■ ■ Copper RJ45 and Fiber Small Form-Factor Pluggable ■ Virtualization Server ■ ■ ■ ■ (SFP) Ports (4 RJ45, 2 RJ45 and 2 SFP, or 4 SFP)

Engineering Access Point ■ ■ ■ ■ EIA-232 Serial Ports, DB-9 Connectors, 300 to 2 2 2 115,000 bps IRIG-B Time Distribution and Network Time Protocol ■ ■ ■ ■ (NTP) Conversion EIA-232/422/485 Serial Ports, RJ-45 Connectors, 300 to 16 115,200 bps, IRIG-B Output Video Surveillance Control and Archiving/Physical ■ ■ ■ ■ Security Monitoring and Notification IRIG-B Input (on COM1) ■ ■ ■

SEL Secure Kiosk ■ ■ ■ ■ IRIG-B Input and Output (PCIe Card) + +

Parallel Redundancy Protocol (PRP) ■ ■ ■ ■ IRIG-B Input and Output (BNC and Serial) ■

19" Rack-Mount Chassis ■ ■ Supported Operating Systems and Software Panel Mount + + SEL Real-Time Automation Controller (RTAC)* + + + + Wall-Mount Chassis ■ ■ SEL BlueFrame™ Operating System (With Kiosk Mode)* + + + + Conductive Panel Mount + + SEL Software* + + + + PCI/PCIe Expansion Slots 5 2 Microsoft Windows 10 IoT Enterprise LTSC* + + + + Additional EIA-232/422/485 Serial Ports, RJ45 Windows Server 2019 Standard* + + + + Connectors, 300 to 921,000 bps, IRIG-B Inputs/Outputs, 24 12 +5 Vdc Power Via PCIe Cards McAfee Whitelist Antivirus* + + + + Additional 10/100/1000 Mbps Ethernet Ports, Copper See Page 162 for a complete list of operating system options. 8 8 RJ45, or Fiber-Optic SFP LC Connectors Via PCIe Cards

Solid-State Drives (2.5" SLC, iMLC, MLC SATA II, Hardware 4 2 2 2 32 GB–7.6 TB Drives) Intel Xeon E3-1505L Quad-Core 2.0 GHz 64-Bit CPU ■ ■ ■ Internal 120/230 Vac, 125/250 Vdc, or 48 Vdc ■ ■ ■ Intel Xeon E3-1515M Quad-Core 2.8 GHz 64-Bit CPU + + Power Supply

Intel Atom x5-E3940 Quad-Core 1.6 GHz 64-Bit CPU ■ Internal Low-Voltage 24–48 Vdc Power Supply ■

4 GB DDR4 ECC PC4-17000 (2,133 MHz) System Memory ■ ■ ■ Secondary 120/230 Vac, 125/250 Vdc, or 48 Vdc + + Power Supply Up to 32 GB DDR4 ECC PC4-17000 System Memory + + + Hot-Swappable Power Supplies ■ ■ 8 GB DDR3L ECC PC3-1600 (800 MHz) System Memory ■ External Power Supply + Triple Independent Video Displays (2 DVI-D and ■ ■ ■ 1 DisplayPort) Alarm Contact, Alarm LED, Watchdog Processor ■ ■ ■ ■

Single DisplayPort With Audio Output (3 Monitors With Configurable Universal Control Input ■ ■ DisplayPort Hub) Programmable Auxiliary Bicolor LEDs 3 3 3 4 HD Audio Ports, Line In, Line Out, Microphone ■ ■ ■ Intel Active Management Technology (AMT) v11.8 ■ ■ ■

Infineon Trusted Platform Module (TPM) v2.0 (Hardware) ■ ■ ■ ■

■ Standard feature + Model option *Factory-orderable operating system

28 | selinc.com | +1.509.332.1890

Serial Port Protocols Applications SEL-3555 SEL-3560E/3560S SEL-3530 SEL-3530-4 SEL-2240 SEL-3505/3505-3 SEL-3532/3533 SEL-2411 SEL-2411P SEL-2440 (Continued) SEL-3555 SEL-3560E/3560S SEL-3530 SEL-3530-4 SEL-2240 SEL-3505/3505-3 SEL-3532/3533 SEL-2411 SEL-2411P SEL-2440

Collect, Scale Meter Data ■ ■ ■ ■ ■ ■ ■ ■ Server

Collect Targets, Contact Input DNP3 ■ ■ ■ ■ ■ ■ + ■ + ■ ■ ■ ■ ■ ■ Status, Fault Location Modbus RTU Binary ■ ■ ■ ■ ■ ■ ■ ■ ■

Enable Fiber-Optic Links ■ ■ ■ ■ ■ ■ ■ ■ ■ IEC 60870-5-101 ■ ■ ■ ■ ■ ■

Control Through IED Outputs ■ ■ ■ ■ ■ ■ LG 8979 ■ ■ ■ ■ ■ ■ Accept IRIG-B Time ■ ■ ■ ■ + + ■ ■ ■ SES-92 ■ ■ ■ ■ ■ ■ Synchronization

Provide IRIG-B Time ■ ■ ■ ■ + + Network Protocols Synchronization Telnet ■ ■ ■ ■ ■ ■ ■ ■ ■ Transparent “Port Switch” ■ ■ ■ ■ ■ ■ ■ ■ ■ FTP ■ ■ ■ Web Server HMI + + + + + DNP3 LAN/WAN Client/Server ■ ■ ■ ■ ■ ■ + ■ + Concentrate IED Data For: Modbus TCP ■ ■ ■ ■ ■ ■ ■ ■ ■ Distributed Control System ■ ■ ■ ■ ■ ■ IEC 61850 MMS Client/Server + + + + + + + + (DCS) IEC 61850 GOOSE + + + + + + + + SCADA Master or Remote ■ ■ ■ ■ ■ ■ Terminal Unit (RTU) IEC 60870-5-104 Client/Server ■ ■ ■ ■ ■ ■

Local or Remote HMI ■ ■ ■ ■ ■ ■ IEEE C37.118 Client/Server ■ ■ ■ ■ ■ ■

Flex Parse ■ ■ ■ ■ ■ ■

Features FTP/SFTP Client/Server ■ ■ ■ ■ ■ ■

Protocol Redundancy (DNP3 and SNMP Client/CDC Type 2 Client/ ■ ■ ■ ■ ■ ■ ■ IEC 60870-5 101/104 Server) Server

Primary and Standby LAN Lightweight Directory Access ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Support Protocol (LDAP)

3 Optoisolated Inputs/ 1 1 ■ + ■ + + ■ + + + EtherCAT® ■ ■ ■ ■ ■ Programmable Outputs 3 EtherNet/IP ■ ■ ■ ■ ■ ■ Rack-Mount or Panel-Mount 2 ■ + + + ■ + + + Precision Time Protocol (PTP)/ Hardware ■ ■ ■ ■ ■ ■ Network Time Protocol (NTP) IEC 61131 Logic Engine ■ ■ ■ ■ ■ ■ Simple Network Time Protocol ■ ■ ■ ■ ■ ■ ■ ■ ■ Cybersecurity Management ■ ■ ■ ■ ■ ■ (SNTP)

Real-Time Operating System ■ ■ ■ ■ ■ ■ ■ ■ ■ Parallel Redundancy Protocol ■ ■ ■ ■ ■ ■ ■ ■ ■ (PRP) Serial Port Protocols

SEL Mirrored Bits® ■ Standard feature + Model option ƒ May be created using settings ■ ■ ■ ■ ■ ■ ■ ■ ■ 1 2 Communications Alarm contact only SEL-3560E/3560S are surface-mount only

3 Client Not supported on SEL-3560S DNP3 ■ ■ ■ ■ ■ ■

Modbus RTU ■ ■ ■ ■ ■ ■

LG 8979 ■ ■ ■ ■ ■ ■

CP 2179 ■ ■ ■ ■ ■ ■

SEL Fast Messages, Interleaved ■ ■ ■ ■ ■ ■ With ASCII

SEL Synchrophasors ƒ ƒ ƒ ƒ ƒ ƒ

IEC 60870-5 101 ■ ■ ■ ■ ■ ■

SES-92 ■ ■ ■ ■ ■ ■

ASCII Flex Parse ■ ■ ■ ■ ■ ■

SCHWEITZER ENGINEERING LABORATORIES | 29 WAN and LAN Networks

SEL ICON® SEL-2740S SEL-2742S NEW The SEL ICON is a WAN multiplexer The SEL-2740S is the industry’s The SEL-2742S is a 12-port, DIN- optimized for industrial and utility first field-hardened software- rail mount SDN switch for industrial applications. By combining TDM defined networking (SDN)-enabled environments. It combines with and Ethernet transport options with switch and improves cybersecurity SEL-5056 Flow Controller Software a comprehensive range of data and Ethernet performance in to simplify network engineering interfaces, the ICON makes it easy to mission-critical applications. and improve LAN security. migrate legacy network technologies to a packet-based solution.

SEL-3620/3622 SEL-2730M/2730U SEL-3610 The SEL-3620 and SEL-3622 each The SEL-2730M/2730U let you build The SEL-3610 increases the function as a router, VPN endpoint, reliable, safe Ethernet networks in number of serial ports available and firewall device. They can provide electrical substations, plants, and to communications processors secure and proxy user access for other mission-critical sites. and computers and allows serial serial- and Ethernet-based IEDs. products to communicate securely through Ethernet networks.

SEL-2725 SEL-3025 The SEL-2725 allows you to The SEL-3025 protects serial easily connect devices to communications with bump- Ethernet networks. in-the-wire security and strong, authenticated access controls.

30 | selinc.com | +1.509.332.1890 Applications ICON® SEL SEL-3620 SEL-3622 SEL-3610 SEL-2725 SEL-2730M SEL-2740S SEL-2742S SEL-2890

SONET WAN ■

Ethernet LAN ■ ■ ■ ■ ■ ■ ■ ■ ■

Precise Time Distribution ■ ■ ■ ■ ■ ■

Engineering Access Control ■ ■ ■ ■ ■

Connect Multiple Wired-Ethernet Devices to Network ■ ■ ■ ■ ■

Convert Wired 10/100BASE-T Ethernet to Fiber-Optic ■ ■ ■ ■ ■ ■ ■ ■ 100BASE-FX Ethernet

Convert Serial Links to Ethernet Links ■ ■ ■ ■ ■

Features

Cryptography (Encryption and Authentication) ■ ■ ■ ■

User-Based Accounts ■ ■ ■ ■ ■ ■ ■

Centralized Authentication Via Lightweight Directory 8 ■ ■ ■ ■ ■ ■ ■ Access Protocol (LDAP)

Centralized Authentication Via Remote Authentication ■ ■ ■ ■ Dial-In User Service (RADIUS)

Deny-by-Default Firewall ■ ■

Import/Export Configuration Files ■ ■ ■ ■ ■ ■

VPN ■ ■

Syslog Logging ■ ■ ■ ■ ■ ■ ■

Network Management System (NMS) Software ■ ■ ■ ■

GPS Receiver ■

Real-Time Latency Monitor ■

1 (STP) ■ ■ ■ ■

VLANs ■ ■ ■ ■ ■ ■ ■

Ethernet Class of Service ■ ■ ■ ■

Ethernet Ports, Connector Quantities

Copper 10BASE-T, RJ45 1

2 3 Copper 10/100BASE-T, RJ45 0–16 3 3 3 3–5 0–16 0–20 2–10

3 Fiber-Optic 100BASE-FX, LC 4 2 2 2 0–2 0–16 0–20 0–6

Copper (GigE), RJ45 4 4 0–4 0–4

6 7 4 Fiber-Optic GigE, LC 2 /4 0–4 0–4 0–4

5 4 Small Form-Factor Pluggable (SFP) Cages 2–6 4

1 SEL-2730M supports STP plus IEEE 802.1D-2004 Rapid Spanning Tree Protocol (RSTP).

2 SEL ICON can support up to 16 Ethernet ports using 8-port Ethernet Access Modules or Ethernet Bridging Access Modules.

3 SEL-2730M base configuration supports sixteen 10/100BASE-T copper ports, with the option to substitute 100BASE-FX fiber-optic ports in groups of four.

4 SEL-2730M base configuration includes 4 copper GigE ports and 4 SFP cages for optional fiber-optic GigE ports.

5 SEL ICON uses SFP cages for SONET and GigE fiber-optic interfaces.

6 SEL-8021-1 Line Module supports 2 fiber-optic Gigabit interfaces.

7 SEL-8036-1 Ethernet Bridging Access Module supports 4 fiber-optic 100BASE-FX/Gigabit interfaces.

8 SEL-5052 Server NMS Software provides LDAP centralized authentication for the ICON.

SCHWEITZER ENGINEERING LABORATORIES | 31 Wireless Communications

SEL-3031 SEL-3061 The SEL-3031 is a 900 MHz ISM serial data radio that The SEL-3061 provides remote access for devices supports point-to-point (P2P) and point-to-multipoint using the public cellular radio network. It supports (P2MP) operational modes. In P2P mode, the SEL-3031 4G LTE, 3G, and 2G cellular technologies. supports three serial data ports in one radio channel.

SEL-2924 SEL-2925 The portable SEL-2924 connects to an EIA-232 port The SEL-2925 connects to an EIA-232 serial port on a relay, controller, or other device to enable secure in a control cabinet or panel to enable Bluetooth Bluetooth® wireless communications from up to 10 m wireless communications from up to 100 m (32 ft) away. (328 ft) away.

32 | selinc.com | +1.509.332.1890 SEL-3031 SEL-3061 SEL-2924 SEL-2925 Applications Setup Method SEL-3031 SEL-3061 SEL-2924 SEL-2925

Wireless Communications for SCADA ■ ■ ■ USB Port ■

High-Speed Teleprotection ■ Secure Web Interface Via Ethernet Port ■

Distribution Automation ■ ■ Control (DIP) Switches ■ ■

Wireless Communications for Synchrophasor Wireless Configuration ■ ■ ■ ■ ■ ■ Data Simple Network Management Protocol (SNMP) ■ Substation-to-Substation Communications Link ■

Anti-Island Detection ■ ■

Wireless Communications for Distributed ■ ■ Generation

Permanent Wireless Cable Replacement ■ ■ ■

Temporary Wireless Cable Replacement ■

Remote Engineering Access ■ ■

Short-Range Engineering Access ■ ■ ■ ■

LAN Extension ■

Wireless Backhaul Communications for Fault ■ and Load Transmitters

Features

915 MHz ISM Band (License-Free) ■

2.4 GHz ISM Band (License-Free) ■ ■

Serial Communication ■ ■ ■ ■

Ethernet Communication ■

Low Latency for Teleprotection ■

Compatible With SEL Mirrored Bits® ■ Communications

Compatible With Modbus ■ ■

Compatible With DNP3 and Typical Byte- ■ ■ ■ ■ Oriented Protocols

Encryption ƒ ■ ■ ■

Point-to-Multipoint Capability ■

Cellular Capability ■

EIA-232 Port (Quantity) 3 1 1 1

Wired EIA-485 Port +

High Maximum Throughput (1 Mbps or Greater) ■

Device Status LEDs ■ ■ ■ ■

Visible Link Quality Indicator ■

■ Standard feature + Model option ƒ With SEL-3044 Encryption Card option

SCHWEITZER ENGINEERING LABORATORIES | 33 Precise Time

SEL-2488 SEL-2407® SEL-2401 The SEL-2488 receives GNSS The SEL-2407 provides a time The SEL-2401 is a satellite time signals and distributes display and high-accuracy clock with high-accuracy precise time via multiple output timing (±100 ns). timing (±100 ns) for compact protocols, including IRIG-B, PTP, spaces. and NTP, with ±40 ns accuracy.

SEL-2404 SEL-3401 SEL-9929 The SEL-2404 is a high- The SEL-3401 provides a The SEL-9929 kit includes a accuracy (±100 ns) satellite highly visible time display for satellite-synchronized clock, a clock with a highly visible use anywhere there are time- large digital clock display, and time display. critical functions set by IRIG-B all accessories to work right out synchronization signals. of the box.

SEL-3400 SEL-3405 SEL-9524 The SEL-3400 verifies time SEL-3405 transceivers The SEL-9524 is a rugged and signals and distributes precise send delay-compensated reliable antenna for GNSS time to 240 devices. demodulated IRIG-B signals devices in critical infrastructure up to 4 km (2.5 mi) over fiber- applications. optic cable.

34 | selinc.com | +1.509.332.1890 Applications SEL-2401 SEL-2404 SEL-2407® SEL-3400 SEL-3401 ICON® SEL SEL-2488

Time Source for Substation ■ ■ ■ ■ ■ ■

Time Source for Industrial Applications ■ ■ ■ ■ ■ ■

Time Source for Phasor Measurement Unit (IEEE C37.118.1-2011 Synchrophasors) ■ ■ ■ ■ ■ ■

Time Source for Recloser ■ ■

Time Source for Line Current Differential Protection ■ ■ ■ ■ ■ ■

Time Source for Traveling-Wave Fault Location ■ ■ ■ ■ ■ ■

Time-Synchronized Event Reporting ■ ■ ■ ■ ■ ■

Long-Distance Viewing, 61 m (200 ft) ■ ■

Time Sources and Time Distribution

Demodulated IRIG-B Outputs (Quantity) 1 4 6 12 4+ 4 up to 8

Modulated IRIG-B Outputs (Quantity) 1 up to 4

GPS Satellite Tracking ■ ■ ■ ■ ■

GLONASS Satellite Tracking (Reference Only) ■

Demodulated IRIG-B Input ■ ■ ■

Synchronized Pulse Output ■ ■ ■ ■

Network Time Protocol (NTP) Server ■

IEEE 1588 Precision Time Protocol (PTP) (With IEEE C37.238 Power System Profile) ■ +

Satellite Signal Verification ■

Features

76.2 mm (3.0 in) LED Display ■ ■

14 mm (0.56 in) LED Display ■ ■ ■

Rack-Mount Hardware ■ ■ ■ ■ ■ ■ ■

Panel-Mount or Wall-Mount Hardware ■ ■ ■ ■ ■ ■

Universal Power Supply ■ ■ ■ ■

Dual, Redundant, Hot-Swappable Power Supplies ■ ■

Power Over Ethernet (PoE) Power Sourcing Equipment (PSE) ■

Secure Web Interface for Configuration ■

Serial Ports for Configuration ■ ■ ■

User-Based Accounts ■ ■

TCXO Holdover ■ ■ ■ ■ ■

OCXO Holdover +

Time-Code Cable Delay Compensation ■ ■ ■

IEEE C37.90 and IEC 60255 Surge and Environmental Standards Compliance ■ ■ ■ ■ ■ ■ ■

Accuracy

Average Accuracy (ns) ±100 ±100 ±100 ±40

Peak Accuracy (ns) ±500 ±500 ±500 ±1,000 ±100

■ Standard feature + Model option/accessory

SCHWEITZER ENGINEERING LABORATORIES | 35 Transceivers and Adapters

SEL-2800/2815 SEL-2810/2812/2814 SEL-2829/2830/2831 Improve safety, signal integrity, and Use EIA-232 multimode fiber-optic Apply the SEL-2829/2830/2831 Single- reliability of EIA-232 communications transceivers instead of wire. The Mode Fiber-Optic Transceiver/Modem by using multimode SEL-2800/2815 SEL-2810 and SEL-2812 support IRIG-B to use two optical fibers instead of wire Fiber-Optic Transceivers instead time signals, while the SEL-2814 works to transfer bidirectional serial data. of wire. with hardware flow control signals.

SEL-2820/2824 SEL-2890 SEL-9192 Apply SEL-2820/2824 Multimode Add Ethernet connectivity to an SEL Connect remote terminal units (RTUs), Fiber-Optic Transceivers to safely add device using its EIA-232 serial port with communications processors, and other isolated segments to multidrop and the SEL-2890 Ethernet Transceiver. equipment with the SEL-9192 Utility- point-to-point EIA-485 networks. Grade USB Modem for dial-up or dial- out engineering access.

SEL-9220 SEL-2894 SEL-2886 Convert the EIA-485 port of an Apply the SEL-2894 Interface Con- Connect EIA-232 devices to an SEL-300 series relay to a point- verter to transfer SEL Mirrored Bits® EIA-485 network with SEL-2886 to-point fiber-optic port with the communications via an IEEE C37.94 EIA-232 to EIA-485 Interface SEL-9220 Fiber-Optic Adapter fiber-optic link through a Converters. for SEL-300 Series Relays. communications multiplexer.

36 | selinc.com | +1.509.332.1890 Connector and Optics SEL-2800 SEL-2810 SEL-2812 SEL-9220 SEL-2814 SEL-2815 SEL-2820 SEL-2824 SEL-2829 SEL-2830 SEL-2831 SEL-2894 V-Pin, 650 nm Wavelength ■ ■ ■

ST, 850 nm Wavelength ■ ■ ■ ■ ■ ■

ST, 1,300 nm Wavelength ■ ■

ST, 1,550 nm Wavelength ■

Fiber Compatibility 200 μm Core Multimode Fiber (SEL-C805) ■ ■ ■ ■ ■ ■ ■ ■

50 or 62.5 μm Core Multimode Fiber ■ ■ ■ ■ ■ ■ (SEL-C807, SEL-C808)

9 μm Core Single-Mode Fiber (SEL-C809) ■ ■ ■

Electrical Features EIA-232 Asynchronous Serial Data ■ ■ ■ ■ ■ ■ ■ ■

EIA-485 Asynchronous Serial Data ■ ■ ■

DTE/DCE Switch ■ ■ ■ ■

IRIG-B Transfer With Data ■ ■ ■

Hardware Flow Control Lines With Data ■ ■

Power From Electrical Port Pins ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

External Power Jack or Terminals ■ ■ ■

Distances Minimum (metric) 1 m 1 m 1 m 1 m 1 m 2 km 1 m 1 m 1 m 16 km 16 km 1 m

Minimum (U.S.) 3.28 ft 3.28 ft 3.28 ft 3.28 ft 3.28 ft 1.24 mi 3.28 ft 3.28 ft 3.28 ft 9.94 mi 9.94 mi 3.28 ft

Maximum (metric) 500 m 500 m 4 km 4 km 4 km 15 km 500 m 4 km 23 km 80 km 110 km 2 km

Maximum (U.S.) 0.3 mi 0.3 mi 2.48 mi 2.48 mi 2.48 mi 9.3 mi 0.3 mi 2.48 mi 14.3 mi 49.7 mi 68.3 mi 1.2 mi

■ Standard feature

SCHWEITZER ENGINEERING LABORATORIES | 37 Cables

SEL-C804 SEL-C805 SEL-C807 Use SEL-C804 Multimode Arc-Flash Connect V-pin or ST ports with Use SEL-C807 62.5/200 μm Detection Fiber-Optic Cables with the SEL-C805 200 μm Multimode Multimode Fiber-Optic Cable SEL-751, SEL-751A, and SEL-710-5 to Fiber-Optic Cable assemblies. assemblies to connect ST or detect arc-flash events. LC ports.

SEL-C808 SEL-C809 Electrical Data Cables Connect ST, SC, or LC ports with Use SEL-C809 9 μm Single-Mode Apply SEL Electrical Data Cables to SEL-C808 62.5/125 μm Multimode Fiber-Optic Cable assemblies to reliably connect SEL products and other Fiber-Optic Cable assemblies. connect ST, SC, or LC ports. devices, including relays, information processors, computers, I/O modules, meters, clocks, and modems.

Coaxial Cables Category 5e Ethernet USB Serial Cables Use SEL Coaxial Cables for GPS and Apply high-quality, shielded twisted- Add a 1.8 m (6 ft) or 4.6 m (15 ft) EIA-232 radio antenna connections and IRIG-B pair (STP) Category 5e Ethernet cables serial port cable to a PC USB port to time distribution. for copper Ethernet connections. communicate with SEL relays and other devices with EIA-232 serial ports.

38 | selinc.com | +1.509.332.1890 SEL-C804 SEL-C805Z SEL-C805D SEL-C805G SEL-C807Z SEL-C807G SEL-C808Z SEL-C808P SEL-C808G SEL-C809Z SEL-C809P SEL-C809G Connector SEL-C804 SEL-C805Z SEL-C805D SEL-C805G SEL-C807Z SEL-C807G SEL-C808Z SEL-C808P SEL-C808G SEL-C809Z SEL-C809P SEL-C809G Jacket Material

V-Pin ■ ■ ■ ■ Polyvinyl Chloride (PVC) ■ ■ ■ ■ ■ ■ ■ ■ ■

ST ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Polyethylene (PE) ■ ■ ■

LC ■ ■ ■ ■ ■ ■ ■ ■ Termination kits

SC ■ ■ ■ ■ ■ ■ V-Pin Termination Kit ■ ■ ■ ■

ST Termination Kit ■ ■ ■ ■ ■ ■ Fiber Diameter (Core/Outer) LC, ST, and SC ■ ■ ■ ■ ■ ■ 1,000 μm ■ Termination Kit

200 μm ■ ■ ■ Options 62.5/200 μm ■ ■ Bulk (No Connectors) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 62.5/125 μm ■ ■ ■ Pulling Loop ■ ■ ■ ■ 9/125 μm ■ ■ ■

Fiber-Optic Compatibility Wavelength SEL-2800/2810/2820 ■ ■ ■ 650 nm (Multimode) ■ ■ ■ SEL-2812/2814/2815/ 850 nm (Multimode) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 2824/3405/9220 1,300 nm (Multimode) ■ ■ ■ ■ ■ SEL-2829/2830 ■ ■ ■ ■ ■ ■ ■ ■ 1,300–1,550 nm ■ ■ ■ SEL-2831 ■ ■ ■ (Single-Mode) SEL-751/751A/710-5 ■ Arc-Flash Detection Fiber Count Multimode Fiber-Optic Simplex (1 Fiber) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ethernet Duplex (2 Fibers) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Single-Mode Fiber-Optic ■ ■ ■ Quad (4 Fibers) ■ ■ ■ ■ Ethernet

■ Standard feature Cable Ratings

Riser-Rated (OFNR) ■ ■ ■ ■ ■ ■ ■

Plenum-Rated (OFNP) ■ ■

Water-Blocked ■

Waterproof ■ ■ ■ ■

SCHWEITZER ENGINEERING LABORATORIES | 39 Remote I/O

SEL-2505/2506/2507 SEL-2515/2516 Reduce operating time, add self-wiring, and simplify wiring Extend contact I/O for SEL information processors with for auxiliary inputs and outputs with the SEL-2505 Remote the SEL-2515 Remote I/O Module and the SEL-2516 Rack- I/O Module, SEL-2506 Rack-Mount Remote I/O Module, and Mount Remote I/O Module. They monitor the status of SEL-2507 High-Speed Remote I/O Module. external contacts transmitted via SEL Fast Meter messages to a communications processor and can control contact outputs using SEL Fast Operate commands.

SEL-2595 SEL-3094 Use the SEL-2595 Teleprotection Terminal to securely Implement the SEL-3094 Interface Converter to convert transfer teleprotection signals through a high-speed electrical teleprotection interfaces to the IEEE C37.94 IEEE C37.94 optical-fiber interface. optical standard for improved safety, signal integrity, and communication over longer distances. Connecting an SEL-3094 to an ITU-T G.703, EIA-422, EIA-485, or EIA-232 device lets you use up to 2 km (1.2 mi) of optical fiber to link to an IEEE C37.94 multiplexer. SEL-2505 SEL-2506 SEL-2507 SEL-2515 SEL-2516 SEL-2595 Applications SEL-2505 SEL-2506 SEL-2507 SEL-2515 SEL-2516 SEL-2595 Number of I/O Channels Save Wiring Via I/O Multiplexing ■ ■ ■ ■ ■ ■ Digital Inputs (DI) Base 8 8 8 8 8 8

1 1 1 I/O for SEL Relays/SEL-3530/SEL-2100 ■ ■ ■ DI Maximum 8 8 8 8 8 8

1 1 I/O for Information Processors ■ ■ Digital Outputs (DO) Base 8 8 8 8 8 8 Transfer I/O to SEL-2505/2506/2507 ■ ■ ■ DO Maximum 8 8 8 8 8 8 Transfer I/O to SEL-2507/T400L With Millisecond Mirrored Bits® ■ Serial Communications Protocols Communications SEL Mirrored Bits Communications ■ ■ ■ Transfer I/O to SEL-2594/2595 ■ SEL Fast Messages ■ ■ Teleprotection ■ ■ ■ ■ IEEE C37.94 ■ Improve Safety With Optical Fiber ■ ■ ■ ■ ■ ■

1 ■ Standard feature With compatible SEL fiber-optic transceiver or interface option at relay or processor

40 | selinc.com | +1.509.332.1890 Annunciation and Notification

Applications SEL-2522 SEL-2523 SEL-2533

Local Visual Indication ■ ■ ■

Remote Visual Indication ■ ■

Local Audible Indication ■ ■ ■

SEL-2523 Remote Audible Indication ■ ■ ■ Provide local and remote notifications with Telephone Dial-Out Messages ■ ■ the SEL-2523 Annunciator Panel, which Local SELogic® Control Equations and ■ ■ includes programmable logic and up to four Time Tagging communications ports. Mounting and Labeling

Rack Mount + +

Panel Mount + + ■

User-Defined Slide-In Labels ■ ■ ■

Inputs, Outputs, and HMI

+ General-Purpose Digital Inputs 36 42 14

+ Acknowledge, Reset, Test Digital Inputs 3 6 4

+ General-Purpose Digital Outputs 1 11 14 SEL-2522 Alarm Digital Output 1 1 1 Apply the SEL-2522 Alarm Panel with up to 36 inputs to easily view the status of alarms General Display LEDs/Windows 36 36 10 and operating events. Enabled LED 1 1 1

Pushbuttons 3 4 4

Base Serial Ports 3 3

Optional Additional EIA-232 or EIA-485 Port 1 1

IRIG-B Time Input 1 1

ISA Annunciation Alarm Sequence Choices 2 8 8

Serial Communications Protocols

SEL Mirrored Bits® Communications ■ ■ SEL-2533 SEL Fast Messages ■ ■ Use the compact, ten-window SEL-2533 Annunciator to Send SEL Messenger Points ■ ■ provide local and remote Modbus RTU ■ ■ annunciation. DNP3 Level 2 Outstation + +

■ Standard feature + Model option

SCHWEITZER ENGINEERING LABORATORIES | 41 Accessories and Tools

SEL-RPM SEL-4388 SEL-4520 Use the SEL-RPM to combine as Accelerate commissioning and bench Use the SEL-4520 Arc-Flash Test many as three ac sources and one testing of SEL Mirrored Bits® links and Module to conveniently test the dc source to provide a single reliable improve training, maintenance, and operation of arc-flash detection relays dc output (unregulated 125 Vdc). cable identification with the SEL-4388 installed in metal-clad and metal- Mirrored Bits Tester. enclosed switchgear.

SEL-2652 SEL-9510 SEL-2126 Verify circuit breaker or lockout relay Use the SEL-9510 Control Switch Apply the SEL-2126 Fiber-Optic trip coil and trip circuit connections Module where independent local Transfer Switch to reroute IEEE C37.94 with the SEL-2652 Trip Coil Monitor. control is needed. High-visibility communications for bypass breaker status indication and arc-suppressed protection during circuit breaker or contacts are ideal for breaker control. station bypass operations.

SEL-2910 SEL-9501/9502 SEL-9321 and SEL-9322 Use the SEL-2910 Port Isolator Decrease maintenance costs, Provide low-voltage dc power to protect the EIA-232 ports of increase contact reliability, and reduce from station battery or ac sources data terminal or communications destructive dc circuit overvoltages for communications devices and equipment from induced voltages. with the self-powered SEL-9501/9502 accessories with SEL-9321 and Contact Arc Suppressors. SEL-9322 dc power supplies.

42 | selinc.com | +1.509.332.1890 Software

acSELerator QuickSet® SEL Grid Configurator NEW acSELerator Architect® QuickSet is a tool to quickly and Grid Configurator is the next Architect streamlines the easily configure, commission, evolution in SEL device configura- configuration and documentation and manage devices for power tion software, allowing you to of IEC 61850 messages, controls, system protection, control, quickly and confidently create, and reports. metering, and monitoring. manage, and deploy settings.

TM SEL RTAC HMI acSELerator Diagram Builder acSELerator Team® The SEL Real-Time Automation Diagram Builder enables the creation Team automates the collection of Controller (RTAC) HMI offers an and management of HMI visualization power system data from multiple easy way to visualize data to projects for the SEL RTACs in your devices and stores the data in a monitor and control your system. system. central location for easy access.

synchroWAVe® Event Synchrowave Operations NEW Software-Defined Network synchroWAVe Event allows you to Synchrowave Operations improves Flow Controller display and analyze SEL relay event operator situational awareness with The SEL-5056 Flow Controller reports and COMTRADE files. wide-area visualization and analytics is the central interface for the solutions for real-time power commissioning, configuration, and system operations. monitoring of all SEL SDN-enabled Ethernet switches.

SCHWEITZER ENGINEERING LABORATORIES | 43 Engineering Services

Protection Automation Protection Services Automation Services Protection solutions and related services for electric Proven automation and integration services using SEL power systems, including scheme designs, relay settings, technology, including solutions for SCADA, distribution and more. network automation, and renewable energy control.

Substation Engineering Services motorMAX® Low-Voltage Motor Management Comprehensive solutions for power and substation design and Protection System projects, from initial cost estimates to a completed substation. Centralized motor management system for comprehensive control, protection, analysis, and monitoring in motor control Arc-Flash Risk-Assessment Services centers (MCCs). Flexible, customized arc-flash risk assessment services to improve employee safety and address regulations. Metering Services Metering solutions for both producers and consumers of Transmission Planning Services energy, including custom solutions for electric power, steam, Transmission planning analysis and design services over water, or gas applications in new or existing facilities. a wide range of study scenarios, from 69 kV to 525 kV.

Synchronizing Systems Conventional and advanced generator and microgrid Cybersecurity synchronizing systems with automatic and manual Cybersecurity Solutions synchronizing. Solutions to improve cyber defense, streamline ongoing Phase-Shifting Transformer (PST) Protection management, and respond to incidents. and Control Systems Pre-engineered PST protection systems based on the SEL-487E Transformer Protection Relay.

Digital Secondary System Solutions SEL Time-Domain Link (TiDL®) and SEL Sampled Values (SV) solutions that advance how you protect and control the primary equipment in your substation.

44 | selinc.com | +1.509.332.1890 ® powerMAX Power Management General Engineering powerMAX Power Management Solutions Design and Drafting Services Integrated control systems composed of scalable relay Full substation design packages, site retrofits for existing and control hardware, software, and logic processing and electrical gear, and detailed design drawings for power system designed by SEL experts. protection, automation, metering, and control. powerMAX for Industrial Power Management Government Engineering Services Power management and control systems specifically Innovative, technologically advanced power management engineered for industries with critical processes that need services and solutions for municipalities and government to stay online, improving power system reliability, personnel organizations, including branches of the military, national safety, and process uptime. laboratories, and governmental agencies. powerMAX for Utilities Engineering Studies and Simulation Services Custom solutions that maintain power system stability Hardware-in-the-loop (HIL) testing services, feasibility studies, by detecting abnormal conditions and taking automatic coordination reports, system stability assessments, and more. corrective actions, including generation and load shedding Custom Panel and Enclosure Solutions and reactive compensation. Custom protection, control, and metering panels; control powerMAX for Mobile Microgrids cabinets; and retrofit doors to match your specifications. Solutions that meet the needs of applications requiring mobility or rapid deployment, such as a military forward operating base (FOB) or a disaster relief effort. powerMAX for Garrison Microgrids Dependable computing and communications, adaptive relaying, cybersecurity, and a TMS-MIL-STD-compliant microgrid controller that is interoperable with all makes and models of generators, inverters, and loads. powerMAX for Commercial Microgrids Comprehensive control, protection, and metering systems to keep your power system operating when separated from the bulk electric grid.

SCHWEITZER ENGINEERING LABORATORIES | 45 Bookstore

Order online at selinc.com/bookstore

Modern Solutions for Protection, Control, and Monitoring of Electric Power Systems The most comprehensive work of its kind, this book consolidates new, modern solutions for protection, control, and monitoring of electric power systems. You’ll find straightforward presentations and example applications of the following technologies:

▪ Time-synchronized protection, control, and monitoring. ▪ Wide-area protection and control using synchrophasors. ▪ Sensible cybersecurity and a security-in-depth tool kit. ▪ Distribution systems that deliver safe operation and rapid power restoration after faults. ▪ Transmission protection solutions that improve stability, detect power swings, and help you get the most out of your primary equipment. Spanish version available

Locating Faults and Protecting Sensible Cybersecurity for Lines at the Speed of Light Power Systems This book, composed of 15 technical papers, This book, composed of over 25 technical explains traveling waves and instantaneous papers, provides an overview of power incremental quantities for line protection and system cybersecurity challenges, fault locating. opportunities, and solutions.

46 | selinc.com | +1.509.332.1890 Wide-Area Protection and Line Current Differential Protection Control Systems This book, composed of 15 technical papers, This book, composed of 41 technical papers, addresses the design and application of line covers the practical technology and solutions current differential protection, communications, for wide-area protection and control that are and fault locating, from both the protection and in service today. communications perspectives.

AC Motor Protection This book, written for the practicing engineer, covers ac motor characteristics and protection principles in a concise and practical way.

Analyzing and Applying Current Transformers This concise book explains fundamental concepts for non- Synchronous Generator linear characteristics, accuracy Protection and Control ratings, and transient behavior This book, composed of 27 technical papers, of current transformers. covers modern technologies for synchronous generator protection, control, and monitoring.

SCHWEITZER ENGINEERING LABORATORIES | 47 SEL University

SEL University trains power system professionals in areas ranging from fundamental power system protection principles to hands-on product application and testing. We provide the training you need to make electric power safer, more reliable, and more economical. Our power system experts have trained tens of thousands of industry professionals worldwide. Our instructors are the same industry experts who design SEL equipment and solutions, support customers, and add to the field of knowledge through industry publications.

Classroom-Based Training Course Types Scheduled classroom-based courses Power system With scheduled SEL University courses, you can: Power system fundamentals for engineers.

▪ Learn at convenient locations around the world. Protection ▪ Receive fundamentals and hands-on training. Power system protection fundamental principles ▪ Network with other industry professionals. and applications. ▪ Easily view the course schedule and register online. Communications Introductory and advanced networking and data On-site and virtual company training communications fundamentals. With our on-site training option, you supply the training Application room and we provide the equipment, course materials, Hands-on settings and applications for and instructors. Training can also be delivered virtually SEL products. using video conferencing software. On-site and virtual training allow you to: Testing ▪ Choose a standard course or mix and match Hands-on relay testing and troubleshooting. standard course material to meet your needs. Systems ▪ Reduce travel expenses and train more employees Advanced hands-on integration and design. at one time. ▪ Address your company’s specific training needs in a confidential environment.

48 | selinc.com | +1.509.332.1890 eLearning Courses SEL University offers several types of eLearning courses Live eLearning that give you flexible training options. These courses act Live eLearning courses are held in real time with as a supplement or substitute for traditional classroom scheduled instruction to provide a live training experience courses. without the expense of travel. The topics relate to SEL products and fundamentals. Self-paced training Live eLearning courses enable you to: Access your training content online at any time with our self-paced eLearning courses. From our complimentary ▪ Maximize your training budget. overview (CBT 101) to more detailed studies of SEL ▪ Maintain flexibility in your schedule. products and fundamentals, these courses can serve as ▪ Attend class from anywhere. a foundation or convenient substitute for our in-depth, ▪ Ask questions and share ideas with your instructor classroom-based courses. and your peers. With SEL University self-paced courses, you can: ▪ Use homework assignments to practice the course ▪ Maximize your training budget. material before follow-up discussions. ▪ Track your eLearning completion status online. ▪ Earn PDHs or CEUs. ▪ Earn professional development hours (PDHs) or continuing education units (CEUs). ▪ Choose an individual or corporate license.

+1.509.338.4026 | [email protected] | selinc.com/selu

SCHWEITZER ENGINEERING LABORATORIES | 49 Ordering and Customer Support

BC, YT MB NF A AB D SK, NT, NU ON H AK QC PE H NS B NB WA MT ND ME N ID MN B VT NH OR SD H WI NY MA S ID MI M E WY CT RI W IA E IA NE PA I NJ OH IL IN MD NV DE UT WV CO K VA CA KS MO G KY L NC C TN OK AR AZ F NM SC HI J GA G MS AL C LA Guam TX

FL

United States and Canada Sales Contact Information

A British Columbia Territory F Arizona Sun Sales, Inc. I A Star Electric Co. Tel: +1.604.297.3020 Tel: +1.602.437.0469 Tel: +1.847.439.4122 Fax: +1.509.332.7990 Fax: +1.602.437.0485 Fax: +1.847.439.4631 [email protected] [email protected] [email protected] selinc.com/support arizonasunsales.com astareg.com

B Peak Measure, Inc. G KD Johnson, Inc. J Power Connections, Inc. Tel: +1.360.263.0123 Tel: +1.903.587.3373 Tel: +1.334.702.6650 Fax: +1.360.263.0124 Fax: +1.903.587.2509 Fax: +1.334.702.0051 [email protected] [email protected] [email protected] peakmeasure.com kdjinc.com powerconnections.com

C Matzinger-Keegan, Inc. H Pro-Tech Power Sales, Inc. K Utility & Industrial Products, Inc. Tel: +1.949.852.1006 Tel: +1.651.633.0573 Tel: +1.888.520.6231 Fax: +1.949.852.1446 Fax: +1.651.633.0610 Fax: +1.866.862.3790 [email protected] [email protected] [email protected] mkireps.com pro-techpower.com uandiproducts.com

D PowerNet Measurement & L Atlantic Power Sales, LLC Control, Ltd. Tel: +1.704.812.8694 Tel: +1.403.571.4735 Fax: +1.704.754.4146 Fax: +1.403.571.4736 [email protected] [email protected] atlanticpowersales.com powernet-mcl.com

M Robinson Sales, Inc. E Rocky Mountain Territory Tel: +1.802.463.9621 Tel: +1.509.336.2666 Fax: +1.802.463.1413 Fax: +1.509.332.7990 [email protected] [email protected] robinsonsales.com selinc.com/support

50 | selinc.com | +1.509.332.1890 Global Sales Contact Information

Corporate Headquarters Europe and Eurasia Asia Pacific USA and Canada Northern Europe Southeast Asia Email: [email protected] Email: [email protected] Email: [email protected] Pullman, WA, USA Stafford, U.K. | Tel: +44.178.524.9876 Ext. 3 Singapore Tel: +1.509.332.1890 | Fax: +1.509.332.7990 Eindhoven, Netherlands | Tel: +31.40.258.1188 Tel: +65.6902.1433 | Fax: +65.6204.6949 Southern Europe Anyang-si, South Korea Latin America Email: [email protected] Tel: +82.31.340.8180 | Fax: +82.31.340.8183 Mexico Madrid, Spain | Tel: +34.910.165.051 Oceania Email: [email protected] Milan, Italy | Tel: +39.02.3652.0632 Email: [email protected] San Luis Potosí | Tel: +52.444.804.2100 Eurasia Melbourne, Australia Mexico D.F. | Tel: +52.55.9171.8900 Email: [email protected] Tel: +61.3.9485.0700 | Fax: +61.3.9480.6560 Monterrey | Tel: +52.818.625.2550 Atyrau, Kazakhstan | Tel: +7.712.230.3121 Brisbane, Australia Villahermosa | Tel: +52.993.478.3940 Tbilisi, Georgia | Tel: +995.32.243.0660 Tel: +61.7.3903.9601 Guadalajara | Tel: +52.33.1253.3550 Perth, Australia Hermosillo | Tel: +52.66.2500.6150 India, Middle East, and Africa (IMEA) Tel: +61.8.9201.6800 | Fax: +61.8.9444.6161 Torreon | Tel: +52.871.478.6100 Indian Subcontinent Sydney, Australia Central America and Caribbean Email: [email protected] Tel: +61.477.023.326 Email: [email protected] Delhi | Tel: +91.11.4520.5500 Christchurch, New Zealand Trinity, FL, USA | Tel: +1.727.494.6000 Bangalore | Tel: +91.80.4246.4200 Tel: +64.3.357.1427 | Fax: +64.3.312.0179 Andina—Colombia, Ecuador, and Venezuela Mumbai | Tel: +91.22.2536.3736 Auckland, New Zealand Email: [email protected] Saudi Arabia Tel: +64.9.522.4392 | Fax: +64.3.312.0179 Bogotá, Colombia | Tel: +57.1.823.7561 Email: [email protected] Hamilton, New Zealand Andina—Bolivia and Peru Khobar | Tel: +966.13.821.8900 Tel: +64.7.855.5946 Email: [email protected] Riyadh | Tel: +966.11.263.2044 Lima, Peru | Tel: +51.1.447.7753 Middle East and Northern Africa Austral—Argentina, Chile, Uruguay, Email: [email protected] and Paraguay Manama, Bahrain | Tel: +973.17.587077 Email: [email protected] Dubai, UAE | Tel: +971.4.392.6333 Buenos Aires, Argentina | Tel: +54.11.4765.2146 Western Africa Brazil Email: [email protected] Campinas-SP | Curitiba-PR | Salvador-BA Accra, Ghana | Tel: +233.55.456.0054 Email: [email protected] Sub-Saharan and Southern Africa Tel: +55.19.3515.5000 | Fax: +55.19.3515.2011 Email: [email protected] Centurion, South Africa | Tel: +27.12.664.5930

SCHWEITZER ENGINEERING LABORATORIES | 51 Popular Models Simplify Ordering

The Popular Models program makes selecting and ordering The popular models are displayed on the webpage for the SEL products simple, fast, and convenient. Through this majority of SEL products, and the webpage clearly shows the program, SEL provides preconfigured product models for technical details and popular applications for each model. You popular applications. Specific models offer discount pricing can order these models directly online or through your SEL and/or ship from stock, typically in 2 business days. sales representative.

selinc.com

Go to product webpage. Select model. Add to project or cart. Purchase.

52 | selinc.com | +1.509.332.1890 2021 Technology Highlights

Example Popular Models for the SEL-2411P Pump Automation Controller

For a complete popular models listing, visit selinc.com/products/popular Select models typically ship in 2 days

Application Details Item No. Price Ultra-High-Speed Protection Capacitor Bank Control Advanced Generator Protection Meet the SEL-T401L Ultra-High-Speed Enhance your distribution system Provide advanced generator, bus, trans- Line Relay, which combines time-domain using the new SEL-734W Capacitor former, and auxiliary system protection Simplex, duplex, and triplex pump control for float switch level control 2411#GJ44 $2,130 USD technologies and high-performance Bank Control with wireless current for hydro, thermal, and pumped-storage and integration with SCADA. distance elements for a complete pro- sensors to improve power quality. applications with the new SEL-400G. tection and monitoring system.

Simplex, duplex, and triplex pump control for float switch level control 2411#BGCG $2,490 USD and/or analog level control and integration with SCADA.

Fault Transmitter and Receiver Synchrowave® Operations Time-Domain Link (TiDL®) Technology Apply the SEL-FT50 and SEL-FR12 Software Convert data using a TiDL merging unit and Simplex, duplex, and triplex pump control for float switch level control and/or analog level control, integration with SCADA, and ac voltage 2411#M9HF $2,700 USD Fault Transmitter and Receiver System Increase grid safety and reliability transport them via fiber to as many as four phase monitoring with diagnostic waveform event reports. to enhance distribution substation with situational awareness of power relays to achieve a simple, secure digital protection and improve the reliability system operations. secondary system solution. and safety of your feeder.

Redundant Power Module Software-Defined Networking powerMAX® Power Management Combine multiple ac and dc power Improve local-area networking with Intelligent control for seamless sources with the new SEL-RPM Redundant deny-by-default cybersecurity and islanding as well as comprehensive Power Module to increase control power fast failover. generation and load management availability and reliability. solutions.

On the Cover

The Tohono O’odham Utility Authority (TOUA) became the world’s first subtransmission utility to experience the SEL-T400L relay’s unprecedented tripping speed. In just over half an hour, the relay tripped seven times—in under 2 ms each time. Read the story of how TOUA made electric transmission protection history at selinc.com/featured-stories/TOUA.

“If not for this new technology, the power would have gone out and our crews would have been driving around and trying to restore it in bad weather. Instead, it did the job so well that we didn’t even know about the disturbance until later.”

—Darrold Hobbs, TOUA Electric Department Operations Manager © 2020 by Schweitzer Engineering Laboratories, Inc. All rights reserved. PRODUCT AND SOLUTION GUIDE

+1.509.332.1890 [email protected] selinc.com Making Electric Power Safer, More Reliable, and More Economical 385-0080