Secutron.Com INTELLIGENT SYSTEMS Intelligent Fire Alarm System www.secutron.com INTELLIGENT SYSTEMS MR-2100/MR-2200 SERIES The MR-2100/MR-2200 Fire Alarm Control Units provide flexible and cost effective operation to satisfy facility requirements. These intelligent fire alarm systems are available in single and dual loop configurations. The control unit network module allows the MR-2100/MR-2200 to be connected to provide a survivable peer-to-peer fire alarm network. • User friendly operation • Removable terminal blocks for easy • One or two SLCs provided in wiring an intelligent fire alarm control unit • Programmable cross-zoning functions, • 198 intelligent devices per SLC day/night mode, and selective control operations • SLCs are selectable for either Class B or Class X performance • LCD/LED system status display with optional LED zone display modules • NACs are selectable for either Class A or Class B performance • Optional Digital Communicator • NAC are expandable to eight circuits • Cabinet doors are removable with optional expander modules for easy installation • Optional LCD and LED annunciators • Windows based programming software • Non-volatile event history log stores 1000+ events NETWORK INTELLIGENT (WIRED COMMUNICATION) DIAGRAM *Mircom Group of Companies manufacturer authorized training required. Secutron A Complete System Solution for Any Project INTELLIGENT FIRE ALARM DEVICES REAL-TIME EVENT NOTIFICATION WHEREVER YOU ARE Secutron™ Intelligent systems are fully Open Graphic Navigator™ is easily configured supported by the industry’s widest selection to instantly communicate Alarm, Supervisory, of Intelligent detection devices. Whatever Trouble and other system events to a your application, Secutron offers the most range of different responding up-to-date heat, smoke detector and duct authorities or personnel, smoke detector designs, including ‘Acclimate’ including fire, security, multi-criteria detectors, as well as a wide range maintenance & service of specialty detectors including advanced staff. Open Graphic beam detectors. Navigator™ means that you’re always connected, 24/7. Intelligent Sensors Secutron’s Intelligent Sensors consists of Photoelectric, Thermal and Multi- Criteria Sensors. The sensors mount in a variety of base styles to accommodate installation requirements. Winner of the 2013 Edison Gold Medal Award in the Advanced Technologies – Smart Systems category for its innovative Open Graphic Navigator. Intelligent Modules Secutron’s Intelligent BUILDING MANAGEMENT SYSTEM INTEGRATION Modules consist of monitor modules, Secutron™ intelligent network systems can be integrated with BACnet™ output modules, compatible heating, cooling, ventilation, humidification, pressurization relay modules and and energy management systems to offer superior fire protection and isolator modules. centralized control of multiple systems. Intelligent Manual Stations Secutron’s Intelligent Manual Stations consist of dual-action addressable manual stations. REMOTE ANNUNCIATORS Secutronannunciators are offered in a range of configurations so you can custom tailor the wired or networked information and control center that is best for your application. Secutron SEC--BR_130021B 11/13 www.mircomgroup.com CORPORATE/CANADA 25 Interchange Way Vaughan, Ontario L4K 5W3 Tel: 888.660.4655 Fax: 888.660.4113 Corporate head office and manufacturing facility, Vaughan, Ontario, Canada USA 4575 Witmer Industrial Estates Niagara Falls, N.Y. About the Mircom® Group of Companies 14305 The Mircom Group of Companies (MGC™) is North America’s largest independent Tel: 888.660.4655 designer, manufacturer and distributor of advanced Fire Detection & Alarm, Voice Fax: 888.660.4113 Evacuation & Communication Systems, and Controlled Access & Security Solutions, serving the global marketplace for over 20 years. INTERNATIONAL MGC owns the Mircom™, Secutron™ branded line of products. With corporate 25 Interchange Way headquarters located in Toronto (Vaughan), Ontario, Canada and Niagara Falls, New Vaughan, Ontario York, U.S.A., MGC operates a dedicated network of sales and service branch offices L4K 5W3 throughout North America and abroad, under its Mircom Engineered ™ ™ Tel: 905.660.4655 Systems brand (Mircom ES ). Fax: 905.660.4113 MGC Systems International Limited supports the sales and installation of MGC systems in more than 100 countries worldwide, with regional offices located in Mexico City, Mexico; Buenos Aires, Argentina; Bangalore, India; Dubai, UAE; and Singapore. Under its United Export Corporation (U.E.C.™) division, MGC distributes a broad range of exceptional fire protection equipment to more than 70 international markets. Information supplied in this document is subject to change without notice. Mircom Technologies Ltd. assumes no responsibility or liability whatsoever for any errors or omissions that may appear in this document. Except as permitted by license, no part of this publication may be reproduced, stored in a retrieval system, transmitted in any form by means electronic, mechanical, using any recorded media, or any other format without the prior written permission of Mircom Technologies Ltd. MGC™, Mircom™, Secutron™ Mircom ES™, and U.E. C.™ names and graphic design are the exclusive property of 7049587 Canada Ltd., used under license by Mircom Technologies Ltd..
Recommended publications
  • Product Announcement Fire Alarm Accessories PA-FCP-016 August 12, 2019
    Product Announcement Fire Alarm Accessories PA-FCP-016 August 12, 2019 FleXNet/MMX Version 12.1.43 Firmware Release & Firmware Update Recommendations As of AUGUST 12,2019 production of the FlexNet product line and components will begin with FlexNet firmware, V12.1.43 replacing FleXNet firware version 12.1.39. This change is to ensure the most current updates and enhancements are provided to new and existing systems. Ideally, this update is intended for new system installations where final testing and verification has not yet been completed. For existing systems, the following recommendations should be considered if upgrading. Existing systems operating older versions are not required to update to this version unless additional features are needed or required. For component replacement or servicing of existing systems, components contain newer software should be downgraded to match the existing system software. Access to older software versions is provided by contacting Mircom Applications Group at [email protected] This update is intended for systems currently operating older V12.1.XX FlexNet series software ONLY. This update is intended for systems currently operating with V12.1.9 software (or newer) since the software changes can be properly assessed and appropriate retesting/verification can be completed in accordance to local governing standards and codes. This update is not recommended for systems currently operating older FlexNet series software such as v10 and v11. Update Enhancements for 12.1.43 Minor Enhancements: Minor updates and improvements MGC Configurator Compatibility The FlexNet v12.1.43 update is compatible with the configuration software MGC Fire Detection and Mass Notification Configurator v12.1.43 FlexNet Hardware Compatibility SO # Part Description Hardware Hardware Rev.
    [Show full text]
  • CAT-5262 ZRS Strobes-ZNS Horn Strobes and ZNH Horns
    SERIES ZRS STROBES, ZNS HORN STROBES AND SERIES ZNH HORNS Features • Approvals include: UL Standard 1971, UL SNAP Standard 464, New York City (MEA), California The EZ Mount State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information • ADA/NFPA/UFC/ANSI and OSHA 29, Part 1910, 165 compliant • EZ Mount SNAP design, with separate base plate, provides ability to pre-wire the base and test the circuit wiring before the walls are covered • The base plate is protected by a disposable cover Series ZNS Series ZNH and the appliances can quickly snap onto the base after the walls are painted. • Patented EZ Mount Universal Mounting Plate – uses single plate for ceiling and wall mount installations • Wall Mount models feature field selectable candela settings of 15/30/75/110cd and 135/185cd • Ceiling Mount models feature field selectable candela settings of 15/30/75/95cd and Series ZRS Series ZRS 115/177cd • Strobes can be synchronized using the Wheelock Description sync modules or power supplies with built-in sync protocol The Wheelock Series Z notification appliances feature an easy snap on base that is designed to • 12 and 24 VDC models with UL “Regulated simplify the installation and testing of horns, strobes, Voltage” using filtered DC or unfiltered VRMS and horn/strobes. The separate Series Z snap on input voltage base can be pre-wired so circuit wiring can be fully • Strobes produce 1 flash per second over the tested before the appliance is installed and before “Regulated Voltage” range (ZNS, ZRS models) the walls are covered.
    [Show full text]
  • Sports, Entertainment,Restaurants
    SPORTS, ENTERTAINMENT, RESTAURANTS & PLACES OF WORSHIP Why Use Different Suppliers When You Can Use One? Mircom offers a robust line of commercial and industrial solutions required to integrate your intelligent building solutions on one unified platform. Fire Controls Ideal for high-rise buildings, Mircom’s FleX-Net V12 supports Advanced Protocol (AP), a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. 159 Sensors & 159 Modules can now be placed on a single SLC Loop. FleX-Net V12 also supports the COSAP FireCO Detector and APB200 Series Sounder bases. Voice Evacuation Fire Devices Mircom’s multi-channel audio voice Mircom evacuation systems offer emergency manufactures a communications with zoned voice complete range paging and firefighter telephone of advanced UL / support. ULC / FM listed The QX-mini is an emergency and conventional and fire alarm audio system designed to addressable fire provide notification for small to medium applications. The QX-mini alarm systems, supplies 30W for audio output and 5A for Notification Appliance detectors, signaling Circuits (NAC). The optional 30 Watt Amplifier Module increases devices, accessories and service tools for any audio output to 60W. new or retrofit application. Building Automation System Communications & Voice Entry Systems Mircom’s OpenBAS (Building Automation System) offers a Mircom offers a complete wide variety of controllers and line of Voice Entry, Building supporting accessories that Automation, and Smart Condo can be easily integrated into solutions. Our Communications any industrial, commercial, & Voice Entry Systems are or residential application. protecting lives and making OpenBAS delivers HVAC, Lighting, Power Metering, and buildings safer in thousands of VAV Fan & Coil control to optimize comfort and energy locations across the globe.
    [Show full text]
  • The Knickerbocker Hotel, Times Square, New York City
    CASE STUDY The Knickerbocker Hotel, Times Square, New York City At a Glance This case study concerns The Knickerbocker Hotel, a historical New York City landmark located in the heart of Times Square. This historic property underwent a major renovation involving the complete replacement of the interior of the building. The renovation and reconstitution as an operating hotel meant the dated fire protection system had to be replaced. The project managers chose Mircom intelligent fire solutions to outfit and protect the new hotel. Safer • Smarter • More Livable Buildings Today, the Knickerbocker Hotel offers 300 rooms, Project Background including 27 Junior Suites and 4 Signature Suites. The Knickerbocker Hotel is a historic building It also features a critically acclaimed restaurant, located in the heart of Times Square at the southeast a coffee shop, and a rooftop lounge overlooking corner of Broadway and 42nd Street in New York City. Times Square. It is situated mere blocks from Fifth Avenue, the Metropolitan Opera, Rockefeller Plaza, the Grand Challenge Central Terminal, and Central Park. Built in 1906 by John Jacob Astor IV, the building is representative The location of the building in the heart of Times of Beaux-Arts style with red-brick construction, Square proved to be a unique challenge. Activity terracotta details and a prominent mansard roof. The and construction in the building could disrupt the hotel was placed on the National Register of Historic regular flow of traffic in New York City. Therefore, the Places in 1980 and was designated a New York City team had to ensure that our work and installation Landmark in 1988.
    [Show full text]
  • Installation Portfolio
    Installation Portfolio Intelligent Fire Panels Corporate Networked Fire Alarm Commercial Voice Evacuation Hospitals/Healthcare Industrial Fire & Gas Controlled Systems Retail Releasing Panels Religious Buildings Access Control Transportation Telephone Entry Sports/Entertainment Emergency Call Restaurants Conventional Fire Alarm Government Educational Industrial Oil/Gas/Petro Chemical Hotels Multi-Unit Residential Installations Alabama Indiana Nebraska South Carolina Alaska Iowa Nevada South Dakota Arizona Kansas New Hampshire Tennessee Arkansas Kentucky New Jersey Texas California Louisiana New Mexico Utah Colorado Maine New York Vermont Connecticut Maryland North Carolina Virginia Delaware Massachusetts North Dakota Washington Florida Michigan Ohio West Virginia Georgia Minnesota Oklahoma Wisconsin Hawaii Mississippi Oregon Wyoming Idaho Missouri Pennsylvania Illinois Montana Rhode Island 2 Government Buildings Oil • Gas • Petro Chemical Oil • Gas Petro Chemical Government Buildings Project Name City | State Project Name City | State Little Rock AFB Little Rock, AR Valero Benicia Benicia, CA China Lake Navy Base China Lake, CA Exxon Chalmette Refinery Chalmette, LA Indio Corporate Yard Indio, CA US Coast Guard Gulf Coast, LA | Industrial Buildings Irvine Community Park, Recreation Bld. Irvine, CA Weatherford Gulf Coast, LA Federal Building 1100 Wilshire Los Angeles, CA Shell Puget Sound Refinery Memphis, TN Frank Hagel Social Security, Administration Building Richmond, CA Atlantis Platform Gulf of Mexico Hagle Federal Building Richmond,
    [Show full text]
  • A Tional Cilities
    EDUCATIONAL FACILITIES Why Use Different Suppliers When You Can Use One? Mircom offers a robust line of commercial and industrial solutions required to integrate your intelligent building solutions on one unified platform. Fire Controls Ideal for high-rise buildings, Mircom’s FleX-Net V12 supports Advanced Protocol (AP), a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. 159 Sensors & 159 Modules can now be placed on a single SLC Loop. FleX-Net V12 also supports the COSAP FireCO Detector and APB200 Series Sounder bases. Voice Evacuation Fire Devices Mircom’s multi-channel audio voice Mircom evacuation systems offer emergency manufactures a communications with zoned voice complete range paging and firefighter telephone of advanced UL / support. ULC / FM listed The QX-mini is an emergency and conventional and fire alarm audio system designed to addressable fire provide notification for small to medium applications. The QX-mini alarm systems, supplies 30W for audio output and 5A for Notification Appliance detectors, signaling Circuits (NAC). The optional 30 Watt Amplifier Module increases devices, accessories and service tools for any audio output to 60W. new or retrofit application. Building Automation System Communications & Voice Entry Systems Mircom’s OpenBAS (Building Automation System) offers a Mircom offers a complete wide variety of controllers and line of Voice Entry, Building supporting accessories that Automation, and Smart Condo can be easily integrated into solutions. Our Communications any industrial, commercial, & Voice Entry Systems are or residential application. protecting lives and making OpenBAS delivers HVAC, Lighting, Power Metering, and buildings safer in thousands of VAV Fan & Coil control to optimize comfort and energy locations across the globe.
    [Show full text]
  • The University of Sharjah, United Arab Emirates
    CASE STUDY The University of Sharjah, United Arab Emirates At a Glance This case study showcases the capabilities of Mircom’s flagship FleX-Net and OpenGN solutions, retrofitted to existing infrastructure at The University of Sharjah, in the United Arab Emirates. The install was completed in two phases in order to convert all 64 campus buildings to the FleX-Net system. The campus buildings collectively span an area of 36,328 m2, which is spread among three floors in each building.Unique features of this project include the usage of a LAN connection to network individual buildings to a central monitoring location and the modification of firmware to accommodate existing older hardware and complicated IT multi-layer design. Safer • Smarter • More Livable Buildings monitoring in one location proved to be a challenge Project Background that had to be expertly solved prior to installation. The University of Sharjah is an Emirati private The team ultimately chose to use a LAN connection national university located in the city of Sharjah, to create the network. However, using the LAN southeast of Dubai. Sharjah is the third largest city presented some complications. The Building LAN in the United Arab Emirates, and a leading center was set up so that each individual building on of education in the Middle East. The Emirate of campus was assigned a multilayered IT design to Sharjah is renowned for its vibrant multicultural increase the LAN security level. Using the LAN ports ambiance and diverse museums, reflecting both meant that Mircom engineers had to modify the rich cultural heritage and contemporary artwork.
    [Show full text]
  • VB 190022 Government-Military-Correctional
    GOVERNMENT, MILITARY & CORRECTIONAL Why Use Different Suppliers When You Can Use One? Mircom offers a robust line of commercial and industrial solutions required to integrate your intelligent building solutions on one unified platform. Fire Controls Ideal for high-rise buildings, Mircom’s FleX-Net V12 supports Advanced Protocol (AP), a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. 159 Sensors & 159 Modules can now be placed on a single SLC Loop. FleX-Net V12 also supports the COSAP FireCO Detector and APB200 Series Sounder bases. Voice Evacuation Fire Devices Mircom’s multi-channel audio voice Mircom evacuation systems offer emergency manufactures a communications with zoned voice complete range paging and firefighter telephone of advanced UL / support. ULC / FM listed The QX-mini is an emergency and conventional and fire alarm audio system designed to addressable fire provide notification for small to medium applications. The QX-mini alarm systems, supplies 30W for audio output and 5A for Notification Appliance detectors, signaling Circuits (NAC). The optional 30 Watt Amplifier Module increases devices, accessories and service tools for any audio output to 60W. new or retrofit application. Building Automation System Communications & Voice Entry Systems Mircom’s OpenBAS (Building Automation System) offers a Mircom offers a complete wide variety of controllers and line of Voice Entry, Building supporting accessories that Automation, and Smart Condo can be easily integrated into solutions. Our Communications any industrial, commercial, & Voice Entry Systems are or residential application. protecting lives and making OpenBAS delivers HVAC, Lighting, Power Metering, and buildings safer in thousands of VAV Fan & Coil control to optimize comfort and energy locations across the globe.
    [Show full text]
  • St. Michael's Hospital
    CASE STUDY St. Michael’s Hospital, Toronto, Ontario, Canada At a Glance St. Michael’s is a leading teaching and research hospital located in downtown Toronto, Ontario. The project involved the design, supply and installation, verification, and maintenance of a new two stage addressable fire alarm system at St. Michael’s 61 Queen Street East Medical Clinic Building. It also included overseeing approvals by the City of Toronto and other authorities. This case study details the challenges tackled during installation, the solutions used, and the benefits of selecting Mircom. Safer • Smarter • More Livable Buildings levels of parking. There are approximately 172,000 Project Background patient visits per year to the various health clinics. Founded in 1892, St. Michael’s Hospital is a leading The existing fire alarm system at 61 Queen Street East downtown teaching hospital located in Toronto, was a single stage MIRTONE 790, with the installation Ontario. As downtown Toronto’s adult trauma having been done in the 1970’s. The building is fully center, the hospital is a hub for neurosurgery, sprinklered with dry sprinkler systems in the below complex cardiac and cardiovascular care, diabetes grade levels. and osteoporosis care, minimally invasive surgery and care of the homeless and disadvantaged. St. In addition to the design, supply and installation, Michael’s is also one of the province’s major sites verification, and maintenance of a new two stage of care for critically ill patients. The hospital is also addressable fire alarm system, Mircom was also affiliated with the University of Toronto, and is a tasked with overseeing various approvals.
    [Show full text]
  • BR 140035 Secutron INTL Installation Portfolio
    International Installation Portfolio Intelligent Fire Panels Transportation Networked Fire Alarm Educational Structures Voice Evacuation Corporate Offices Industrial Fire & Gas Controlled Systems Commercial Releasing Panels Hospitals/Healthcare Government Buildings Access Control Oil/Gas Telephone Entry Hotels Emergency Call Power Utilities Conventional Fire Alarm Retail Sports/Entertainment Industrial Buildings Multi-Unit Residential International Installations Algeria India Samyan Bahrain Jordan Saudi Arabia Bangladesh Kuwait South China Belgium Mexico Gulf Sri Lanka Cameron Oman Sudan Canada Pakistan Taiwan Chad Panama Thailand Chile Peru UAE Ecuador Phillippines USA Egypt Qatar 2 PRO - 2000 Oil & Gas PRO - 2000 Industrial PRO-2000 Oil Gas | Industrial, Power Utilities Sports • Entertainment Project Name City | Country Project Name City | Country Hanger Protection Algeria Antena Exploracion Espacio Profundo Rhourde Nouss - Gas Processing Plant Algeria Europe Aeroespace Agency Argentina Oil Refinery Argentina Airport Fuel Farm Belgium Aluminium Bahrain Bahrain Brussels Airport Belgium HIBERNIA Oil Platform - Top Sides Canada European Union Headquarters Belgium Onshore Oil & Gas Distribution Facility Cameroon Hospital Belgium Onshore Oil & Gas Distribution Facility Chad Chemical Processing Plant Canada Wilmar Surabaya, Indonesia Newfoundland Transshipment Terminal Canada KNPC boiler & Heater Upgradation Project Kuwait Munitions Plant Canada Vastar Horn Mountain Platform Mexico Gulf Exhibition Hall Detection Upgrade Taiwan Oil Refinery
    [Show full text]
  • Micare Wireless Nurse Call Is a Leading Edge Network That Saves You Time and Money
    mircom.com/micare The Power of Wireless Mesh Networks The MiCare Dierence Ì The only wireless system with 2 Way Voice Ì Dual Method Locating: Ultrasonic & Triangulation Ì Web Enabled - no dedicated console Ì True Wireless Plug & Play MiCare Makes Managing Easier Using an Advanced Mesh Network, MiCare makes residents and patients safer than ever before: ü Fully Supervised System ü Comprehensive Reporting Every device is software supervised. Know what happened. Know where it happened. Clear, Concise and Customizable. ü Easily Customizable Almost every feature can be customized ü Centralized Management to your needs. Update devices remotely. ü Wireless Mesh Network ü Industry Leading Quality No Wires. Easy Installation. ETL Listed to UL 1069 and UL 2560 FCC/IC and CSA (C22.2 No.205) Certified MiCare Wireless Nurse Call is a Leading Edge Network that Saves You Time and Money Not only is it fast and easy to install, but there is little labour intensive wiring. This powerful wireless solution provides big advantages over typical wired systems: Self-Healing Should one unit fail or lose power, other nearby units take over the notification task. Self-Aware As each unit becomes initiated, it begins communicating with all devices within its proximity. Unified Protocols This means you can communicate with any MiCare Peripherals or Beacons within the facility. The Most Feature-Rich Wireless Nurse Call On The Market! ü Easy installation for retrot sites and ü Four supervised inputs for wired new builds. pullcords, environmental triggers, and personal monitors. ü Centralized programming from our MiCare Central Software using global or ü Four dedicated outputs for dome lights, targeted congurations.
    [Show full text]
  • List of Creditors
    IN THE MATTER OF THE COMPANIES' CREDITORS ARRANGEMENT ACT , R.S.C. 1985, c. C-36, AS AMENDED AND IN THE MATTER OF THE CANADA BUSINESS CORPORATIONS ACT , R.S.C 1985, c. C-44 IN THE MATTER OF STERLING SHOES INC. AND STERLING SHOES GP INC. List of Known Creditors of Sterling Shoes Inc., Sterling Shoes GP Inc., and Sterling Shoes Limited Partnership as at October 20, 2011 Prepared as at February 8, 2012 * Amount Name Address $CAD ** Trade and Other Unsecured Creditors 1 1St Place Fire Protection Inc. 4141 Sladeview Cr, Unit 18 Mississauga ON L5L 5T1 Canada 96.05 2 818 Sports Llc - Canada C/O Rbc Attn: Oso Desk 2514 Bayview Avenue Toronto ON M2L 1A9 Canada 130,308.08 3 AAA Alarms Systems Ltd 180 Nature Park Way Winnipeg MB R3P 0X7 Canada 553.04 4 ABC Cleaning Services Surrey Place Po Box 33517 Surrey BC V3T 5R5 Canada 4,572.96 5 Abell Pest Control Inc. 7634 Winston Street Burnaby BC V5A 2H4 Canada 637.43 6 Access Pacific Ent. Ltd. 109 - 5560 Minoru Boulevard Richmond BC V6X 2A9 Canada 20,634.88 7 Accord Financial C/O Jaytex Group 77 Bloor St.W.18th Floor Toronto ON M5S 1M2 Canada 39,785.09 8 Ace Courier Services P.O. Box 3672 Vancouver BC V6B 3Y8 Canada 7,037.62 9 Acme Protective Systems Limited 1632 West 6Th Avenue Vancouver BC V6J 1R3 Canada 102.51 10 Adidas-Solomon 8100 Highway 27 Woodbridge ON L4H 3N2 Canada 65,389.60 11 Adt Security Services Canada, Inc.
    [Show full text]