Prices as of April 27, 2016. Check Web site for most current prices.

Company Information

Drives

Soft Starters

Level Motors

Power Transmission

Motion: Servos and Steppers

Motor Controls

Sensors: Proximity

Up-to-date price list: Sensors: Photoelectric www.automationdirect.com/pricelist Sensors: FREE Technical Support: Encoders www.automationdirect.com/support Sensors: Limit Switches

FREE Videos: Sensors: www.automationdirect.com/videos Current Sensors: In this interactive PDF you can: FREE Documentation: • Use bookmarks to navigate www.automationdirect.com/documentation Sensors: by product category FREE CAD drawings: Sensors: • Use bookmarks to save, www.automationdirect.com/cad Level search, print or e-mail the Sensors: catalog section Flow

Pushbuttons • Click on part #s to link and Lights directly to our online store for current pricing, specs, Stacklights stocking information and Signal more Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-1 Prices as of April 27, 2016. Check Web site for most current prices. Level Sensors and Switches

Flowline® Ultrasonic Level Sensors and Switches (Non-contact) The Flowline EchoPod®, EchoSonic® II, Echotouch™, EchoSpan® and EchoSwitch® are innovative ultrasonic liquid level families that replace float, conductance and pressure sensors that fail due to contact with dirty, sticky and scaling in small, medium and large capacity tanks. These liquid level sensors can be used in either open or enclosed tanks (not suitable for pressurized tanks). PC software configured or pushbutton config- ured models are available. Software Configured Ultrasonic Liquid Level Pushbutton Configured Ultrasonic Liquid Level Sensors & Switches Sensors & Switches

Software Configuration: For software configured sensors, PC Pushbutton Configuration: With no software or PC required, configuration is simple with FREE (download) WebCal™ level the Echotouch, EchoSpan, and EchoSwitch ultrasonic level sensor software and the programming fob with USB adapter. sensors are easily configured using integral pushbuttons and LCD digital display. Configuration parameters are organized • EchoPod DS14 Series Ultrasonic Liquid Level Switch & Controller in a simple menu structure so that parameter values are easily • EchoPod DX10 and DL10 Series Ultrasonic Liquid Level Transmitters accessed and set or changed as needed. • EchoPod DL Series Multi-Function Ultrasonic Liquid Level Sensors • Echotouch™ LU20 Ultrasonic Level Transmitter • EchoSonic II LU Series Ultrasonic Liquid Level Transmitters • EchoSpan® LU Series Ultrasonic Level Transmitters • EchoSwitch® LU Series Ultrasonic Level Sensors WebCal Ultrasonic Level Sensor Configuration Software and Fob USB Adapter PodView® • Free WebCal Configuration Software (download only) The PodView digital level indicator is a low-cost general purpose • WebCal Software CD also availaible for purchase level indicator that displays engineering units for level or volume • LI99-1001 fob USB adapter and is compatible with the EchoPod Series ultrasonic sensors.

Flowline Level Sensors (Contact) • Ultrasonic Level Switches: are intrinsically safe and provide reliable liquid level detection of chemical, solvent, hydrocarbon and petroleum based liquids. • Vibration Point Level Switch: provides reliable liquid level detection of dirty liquids such as those with light to medium coating, scaling or foaming characteristics. • Capacitance Level Switch: provides reliable high or low liquid level detection of water based conductive liquids with light coating, crystalizing or scaling characteristics with a 1A relay output. • Buoyancy Level Switch: provides reliable liquid level detection of relatively clean water and chemical solutions.

Book 2 (14.3) eLE-2 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Information

Drives Flowline Level Controllers Soft Starters Switch-Pro™ general purpose level controllers are available in three discrete sensor input configurations for alarms, pump and valve control. Motors The LC52 DataPoint™ general purpose controller for analog sensor inputs provides single tank level indication with 2 relays, up to three setpoints and Power Transmission an isolated analog repeater. • Switch-Pro LC40 Remote Level Controller: one level sensor input Motion: Servos and one non-latching 10A relay output for high level or low level alarm and Steppers

• Switch-Pro LC41 Remote Level Controller: two level sensor inputs Motor Controls and one latching 10A relay output for automatic fill or empty control • Switch-Pro LC42 Remote Level Controller: three level sensor inputs Sensors: and one latching 10A relay output and one nonlatching 10A relay output Proximity

• DataPoint LC52 Remote Level Controller: one 4-20 mA input, two relay outputs, Sensors: • one 4-20 mA output Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

ProSense® Submersible Level Sensors Sensors: The SLT1 series has a slim 1-inch diameter housing and a ported bullet Pressure

nose cap for protection of the sensor diaphragm. The SLT2 series features Sensors: a large 2.75 inch diameter PTFE flexible diaphragm surrounded by a 316 Temperature stainless steel non-fouling protective cage. Sensors: • SLT1 Series Transmitter with 1-inch Diameter Housing Level • SLT2 Series Transmitter with 2.75-inch Diameter Diaphragm and Protective Cage Sensors: • Submersible Level Transmitter Vent Filter Flow • Submersible Level Transmitter Bellows • Junction Boxes for Submersible Level Transmitters Pushbuttons and Lights • Submersible Level Transmitter Replacement Nose Caps Stacklights

Signal Devices

ProSense Float Level Switches Process These switches are available in several different material constructions for Relays and compatibility with many types of liquids, a wide temperature range, and Timers various system pressure requirements. Vertical and horizontal mounting styles with several mounting thread variations are available for ease of Pneumatics: Air Prep installation. • Vertical Top-Mount Pneumatics: Directional Control • Vertical Suspendible / Submersible Valves • Horizontal Side-Mount Pneumatics: • Float Level Switch Kits Cylinders • Float Level Tilt Switches Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-3 Prices as of April 27, 2016. Check Web site for most current prices. Ultrasonic Liquid Level Sensors Quality level sensing solutions from Flowline and AutomationDirect! • Innovative ultrasonic liquid level sensor families that replace float, • For input to a PLC or other controller, measurement conductance and pressure sensors outputs include current, voltage and frequency • Applied in chemical, water and wastewater applications, these general • Models with four relays can be configured for level alarms and/or purpose non-contact sensors are available with single and multi-func- stand-alone level control such as automatic fill or empty functions tion capabilities including continuous level using the embedded level controller measurement, switching and control. • Software and pushbutton configurable models available

EchoPod® & EchoSonic® II Ultrasonic Liquid Level Sensors

PC configuration is simple with FREE WebCal™ software.

PodView® The PodView digital level indicator is a low-cost general purpose level indi- cator that displays engineering units for level or volume and is compatible with the EchoPod Series ultrasonic sensors.

Echotouch™, EchoSpan® & EchoSwitch® Ultrasonic Liquid Level Sensors

Units are easily configured using built-in pushbuttons

Book 2 (14.3) eLE-4 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. ® ® Company EchoPod & EchoSonic II Information Ultrasonic Liquid Level Sensors Drives Soft Starters

Motors The EchoPod and EchoSonic II are innovative ultrasonic liquid level sensor families that replace float, conductance and Power pressure sensors that fail due to contact with dirty, sticky and Transmission scaling media in small, medium and large capacity tanks. Motion: Servos Applied in chemical, water and wastewater applications, these and Steppers general purpose non-contact sensors are available with single and multi-function capabilities including continuous level Motor Controls measurement, switching and control. Sensors: For input to a PLC or other controller, measurement outputs Proximity include current, voltage and frequency. Models with four relays can be configured for level alarms and/or stand-alone Sensors: level control such as automatic fill or empty functions using Photoelectric the embedded level controller. PC configuration is simple with Sensors: WebCal™ software. Encoders

Sensors: Limit Switches

Sensors: EchoPod & EchoSonic II Ultrasonic Liquid Level Sensors General Specifications Current Model DL34-00 DL24-00 DL14-00 DS14-00 DX10-00 DL10-00 LU27-00 LU23-00 LU28-00 LU29-00 Sensors: Price $539.00 $446.00 $353.00 $330.00 $279.00 $306.00 $497.00 $590.00 $683.00 $776.00 Pressure

Type EchoPod EchoSonic II Sensors: Temperature Class General Purpose (non-hazardous) 8 in to 18 ft (20 4 in to 9.8 ft 4 in to 9.8 ft 8 in to 18 ft (20 8 in to 26.2 ft 8 in to 32.8 ft Sensors: Range cm to 5.5m) (10 cm to 3m) 2 in to 4.1 ft (5 cm to 1.25m) (10 cm to 3m) cm to 5.5m) (20 cm to 8m) (20 cm to 10m) Level

4-20 mA and (4) SPST relays (4) SPST relays 0-5V, 0-10V, 4-20 mA Sensors: Output Types 976-2000 Hz Flow Vertical, top of tank Install Pushbuttons Mounting 2 in MNPT 1 in MNPT 2 in MNPT and Lights

Relays (4) SPST No Relay Stacklights WebCal Software (free download) and LI99-1001 Fob USB Adapter (purchased separately) Configuration Signal Devices Ambient -31° to 140°F (-35° to 60°C) Temperature Process Process 20° to 140°F (-7° to 60°C) -4° to 140°F (-20° to 60°C) Temperature Relays and Pressure 30 PSI (2 bar) max. Timers

Pneumatics: WebCal Software Air Prep WebCal PC software is a utility program that allows users to easily configure their EchoSonic II and EchoPod level Pneumatics: Directional Control transmitters, switches, and controllers. Download your free copy of WebCal at www.AutomationDirect.com, and Valves WebCal connect your sensor through our Fob USB adapter (LI99-1001). Develop your configuration using pre-programmed Pneumatics: function menus as the tank graphic and set point fields automatically change to match your configuration. Then, Cylinders input your level set point values and click the Write to Unit button. Your configuration will be downloaded into the sensor and verified in less than a second. Last, click the Wiring Diagram button to open a wiring sche- Pneumatics: Tubing matic of your configuration in PDF format. Print the document, disconnect the sensor and wire it per the sche- LI99-1001 matic. As new software or firmware becomes available, they can be downloaded and updated through WebCal. Pneumatics: Air Fittings PodView® Appendix The PodView digital level indicator is a low cost general purpose level indicator that displays engineering units for Book 2 level or volume and shares power with an EchoPod ultrasonic sensor, including loop powered devices. The LI40 Terms and can be field mounted for local indication as well as be used to make simple setting changes to the sensor. The Conditions LI40-1001 display can be easily attached to any EchoPod sensor that has been configured with WebCal 6.0 / firmware 50.0 or higher. PodView displays sensor output and can reconfigure sensor setpoints on the fly. PodView shares power with the sensor and does not require any additional outside power supply.

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-5 Prices as of April 27, 2016. Check Web site for most current prices. EchoPod DS14 Ultrasonic Liquid Level Switch & Controller Overview The EchoPod DS14 ultrasonic liquid level switch provides continuous level detection up to 4.1 ft (1.25m), with 4 programmable relays for level switch or level control functions, and is configured via WebCal software. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is broadly selected for small day tank, skid, intermediate bulk tanks, sump and process tank level applications. Features • Continuous level detection up to 4.1 ft (1.25 m) • Configuration is fast and easy via WebCal software and USB adapter • Narrow 2 inch beam width and short 2 inch dead band optimized for small tanks • Four programmable relays for switch, pump or valve control and fail-safety - 1 pump or valve with 3 alarms - 2 pumps (lead-lag) with 2 alarms DS14-00 Technical Specifications - 2 pumps (duplexing) with 2 alarms - 4 independent outputs Price $330.00 • PVDF transducer and NEMA Type 6P polycarbonate enclosure for corrosive liquids, Range 2 in to 4.1 ft (5 cm to 1.25m) UV stable for outdoor use Accuracy 0.125 in (3 mm) • Automatic temperature compensation for accurate measurement Resolution 0.019 in (0.5 mm) • Made in the USA Sensing Dead Band* 2 in (5 cm) Agency Approvals Beam Width 2 in (5 cm) • cFMus WebCal Free Software and Configuration LI99-1001 USB Fob Adapter Memory Non-volatile Dimensions Supply Voltage 12 to 24 VAC/VDC inches [mm] Consumption 0.5W Output Type (4) SPST relays 120 VAC/DC @ 0.5A; Contact Voltage Ratings 30 VAC/DC @ 1A Power loss: Hold last Contact Fail-Safe Echo loss: Open, close or hold last Hysteresis Selectable Process Temperature 20° to 140°F (-7° to 60°C) Temp. Compensation Automatic Ambient Temperature -31° to 140°F (-35° to 60°C) Pressure 30 PSI (2 bar) MAX NEMA Type 6P, IP67, encapsulated, Enclosure Rating corrosion resistant & submersible, UV stable Enclosure Material Polycarbonate Strain Relief Material Santoprene Configuration Wiring Transducer Material Polyvinylidene Flouride The settings for the the DS14 are configured Red - Power Cable Jacket Material Polyurethane with free WebCal software (downloadable Blk - Return from AutomationDirect Web site), and an Wht - TX (Out) Cable Type 9-conductor, shielded Grn - RX (In) Cable Length 48 in (1.2m) LI99-1001 Fob USB adapter (purchased Blu - Rly 1 1 in MNPT (See accessories for separately). Org - Rly 2 Process Mount installation fittings) Yel - Rly 3 Viton® (included, replacement part Pur - Rly 4 Mount Gasket Brn - Rly Com number 204038) BLAC K WHIT E GREEN RED Weight (lbs) 0.5 Classification General purpose CE, RoHS Compliance PART NO.: LI99-1001 Agency Approvals cFMus * Dead band is the minimum distance the sensor must be mounted above the max liquid level. See the end of the Ultrasonic Level Sensor Section for further details and Accessories Book 2 (14.3) eLE-6 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company EchoPod DX10 Ultrasonic Information Liquid Level Transmitter Drives Soft Starters Overview Motors The EchoPod DX10 ultrasonic liquid level transmitter provides continuous level Power measurement up to 4.1 ft (1.25m), with a selectable 0-5 VDC, 0-10 VDC or Transmission 976-2000 Hz frequency signal output, and is configured via WebCal software. Select the voltage output for interface with analog input cards. Select the frequency Motion: Servos output for interface with discrete input cards. This non-contact liquid level sensor is and Steppers ideally suited for corrosive, sticky or dirty liquids, and is broadly selected for small Motor Controls day tank, skid, intermediate bulk tanks, sump and process tank level applications. Sensors: Features Proximity • Continuous non-contact level measurement output up to 4.1 ft (1.25 m) Sensors: Photoelectric • Selectable voltage (analog) or frequency (discrete) signal outputs • Configuration is fast and easy via WebCal software and USB adapter Sensors: Encoders • Narrow 2 inch beam width and short 2 inch dead band optimized for small tanks • PVDF transducer and NEMA Type 6P polycarbonate enclosure for corrosive liquids, Sensors: UV stable for outdoor use Limit Switches DX10-00 Technical Specifications • Automatic temperature compensation for accurate measurement Sensors: Price $279.00 • Made in the USA Current Range 2 in to 4.1 ft (5 cm to 1.25m) Sensors: Accuracy 0.125 in (3 mm) Agency Approvals Pressure Resolution 0.019 in (0.5 mm) • cFMus Sensors: Sensing Dead Band* 2 in (5 cm) Temperature Beam Width 2 in (5 cm) Dimensions Sensors: WebCal Free Software and inches [mm] Level Configuration LI99-1001 USB Fob Adapter Memory Non-volatile Sensors: Flow Supply Voltage 12 to 24 VDC Consumption 0.5W Pushbuttons Signal Output 0-5V, 0-10V, 976-2000 Hz and Lights

Minimum Load 800Ω at 12 VDC; 1600Ω at 24 VDC Stacklights Output Current Sink current, 15 mA nominal Signal Signal Invert 5-0V, 10-0 V, 2000-976 Hz Devices Signal Fail-Safe Full, empty or hold last Process Temperature 20° to 140°F (-7° to 60°C) Process Automatic Temp. Compensation Relays and Ambient Temperature -31° to 140°F (-35° to 60°C) Timers 30 PSI (2 bar) MAX Pressure Pneumatics: NEMA Type 6P, IP67, encapsulated, Air Prep Enclosure Rating corrosion resistant & submersible, UV stable Configuration Wiring Pneumatics: Enclosure Material Polycarbonate Directional Control The settings for the the DX10 are configured Red - Power Valves Strain Relief Material Santoprene with free WebCal software (downloadable Blk - Return Wht - TX (Out) Pneumatics: Transducer Material Polyvinylidene Flouride Cylinders from AutomationDirect Web site) and an Grn - RX (In) Cable Jacket Material Polyurethane LI99-1001 Fob USB adapter (purchased Pneumatics: Cable Type 6-conductor, shielded separately). Tubing Cable Length 48 in (1.2m) Blu - Voltage Out Pneumatics: 1 in MNPT (See accessories for Brn - Frequency Out Air Fittings Process Mount installation fittings) BLAC K WHIT E GREEN RED Viton® (included, replacement part Appendix Mount Gasket number 204038) Book 2 Weight (lbs) 0.5 PART NO.: LI99-1001 Terms and Classification General purpose Conditions Compliance CE, RoHS Agency Approvals cFMus * Dead band is the minimum distance the sensor must be mounted above the max liquid level. When installing the 1 inch NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. See the end of the Ultrasonic Level Sensor Section for further details and Accessories Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-7 Prices as of April 27, 2016. Check Web site for most current prices. EchoPod DL10 Ultrasonic Liquid Level Transmitter Overview The EchoPod DL10 ultrasonic liquid level transmitter provides continuous level measurement up to 4.1 ft (1.25m), with a 4-20mA signal output, and is config- ured via WebCal software. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is broadly selected for small day tank, skid, intermediate bulk tanks, sump and process tank level applications. Features • Continuous non-contact level measurement output up to 4.1 ft (1.25m) • 4-20 mA output for longer signal distances, up to 1000 ft. (300 m) • Configuration is fast and easy via WebCal software and USB adapter • Narrow 2 inch beam width and short 2 inch dead band optimized for small tanks • PVDF transducer and NEMA Type 6P polycarbonate enclosure for corrosive liquids, UV stable for outdoor use • Automatic temperature compensation for accurate measurement DL10-00 Technical Specifications • Made in the USA Price $306.00 Range 2 in to 4.1 ft (5 cm to 1.25m) Agency Approvals Accuracy 0.125 in (3 mm) • cFMus Resolution 0.019 in (0.5 mm) Dimensions Sensing Dead Band* 2 in (5 cm) inches [mm] Beam Width 2 in (5 cm) WebCal Free Software and Configuration LI99-1001 Fob USB Adapter Memory Non-volatile Loop Supply Voltage 14-28 VDC1 Consumption 0.5W Loop Resistance 500Ω max at 24 VDC Signal Output 4-20 mA, two-wire Signal Invert 4-20 mA or 20-4 mA 4 mA, 20 mA, 21 mA, 22 mA or Signal Fail-Safe hold last Process Temperature 20° to 140°F (-7° to 60°C) Temp. Compensation Automatic Ambient Temperature -31° to 140°F (-35° to 60°C) Pressure 30 PSI (2 bar) MAX NEMA Type 6P, IP67, encapsulated, Enclosure Rating corrosion resistant & submersible, UV stable Configuration Wiring

Enclosure Material Polycarbonate The settings for the the DL10 are Red - Power Strain Relief Material Santoprene configured with free WebCal Blk - Power Return or 4-20mA Loop Output software (downloadable from Wht - TX (Out) Transducer Material Polyvinylidene Flouride Grn - RX (In) AutomationDirect Web site) and Cable Jacket Material Polyurethane an LI99-1001 Fob USB adapter Cable Type 4-conductor, shielded (purchased separately). Cable Length 48 in (1.2m) 1 in MNPT (See accessories for Process Mount installation fittings)

Viton (included, replacement part BLAC K WHIT E GREEN RE D Mount Gasket number 204038) Weight (lbs) 0.5 Classification General purpose Compliance CE, RoHS PART NO.: LI99-1001 Agency Approvals cFMus * Dead band is the minimum distance the sensor must be mounted above the max liquid level. 1 If supply exceeds 28 VDC damage to the When installing the 1 inch NPT level sensors care should be used to mechanically isolate the sensor housing from transmitter may occur. the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. See the end of the Ultrasonic Level Sensor Section for further details and Accessories Book 2 (14.3) eLE-8 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company EchoPod DL Series Multi-Function Information Ultrasonic Liquid Level Sensors Drives Soft Starters

Overview Features Motors The EchoPod DL series multi-function ultrasonic liquid level sensors • Switch and control functions with continuous level measurement analog output up to 4.1 ft (1.25m), 9.8 ft (3m) or 18 ft (5.5m) Power provide continuous level measurement up to 4.1 ft (1.25m), 9.8 ft Transmission • Configuration is fast and easy via WebCal software and USB adapter (3m), or18 ft (5.5m), with a 4-20mA signal output and 4 program- • Narrow beam width and short dead band optimized for small tanks Motion: Servos mable relays for level switch or level control functions, and are and Steppers configured via WebCal software. The embedded level controller • 4-20 mA signal output and four programmable relays rated at can lower cost by replacing external control hardware. This 1A / 60VA for switch, pump or valve control and fail-safety Motor Controls non-contact liquid level sensor is ideally suited for corrosive, sticky - 1 pump or valve with 3 alarms - 2 pumps (lead-lag) with 2 alarms Sensors: or dirty liquids, and is broadly selected for small day tank, skid, - 2 pumps (duplexing) with 2 alarms Proximity intermediate bulk tanks, sump and process tank level applications. - 4 independent outputs Sensors: • PVDF transducer and NEMA Type 6P polycarbonate enclosure for Photoelectric corrosive liquids, UV stable for outdoor use Sensors: • Automatic temperature compensation for accurate measurement Encoders • Made in the USA Sensors: Agency Approvals Limit Switches

Part No. DL14-00 Part No. DL24-00 Part No. DL34-00 • cFMus Sensors: Current DLx4 Series Technical Specifications Sensors: Model DL14-00 DL24-00 DL34-00 Pressure Price $353.00 $446.00 $539.00 Sensors: Range 2 in to 4.1 ft (5 cm to 1.25m) 4 in to 9.8 ft (10 cm to 3m) 8 in to 18.0 ft (20 cm to 5.5m) Temperature Accuracy 0.125 in (3 mm) ± 0.2% of range 0.019 in (0.5 mm) 0.039 in (1 mm) 0.079 in (2 mm) Sensors: Resolution Level Sensing Dead Band* 2 in (5.1 cm) 4 in (10.2 cm) 8 in (20.3 cm) Beam Width 2 in (5.1 cm) 2 in (5.1 cm) 3 in (7.6 cm) Sensors: Flow Configuration WebCal Free Software and LI99-1001 Fob USB Adapter Memory Non-volatile Pushbuttons and Lights Loop Supply Voltage 14 - 28 VDC1 Consumption 0.5W Stacklights Loop Resistance 500Ω max @ 24 VDC Signal Signal Output 4-20 mA, two-wire Devices Signal Invert 4-20 mA or 20-4 mA Loop Fail-Safe 4 mA, 20 mA, 21 mA, 22 mA or hold last Process (4) SPST relays Contact Type Relays and Contact Ratings 0.5A @ 120 VAC/DC; 1A @ 30 VAC/DC Timers Contact Fail-Safe Power loss: Hold last; Echo loss: Open, close or hold last Pneumatics: Hysteresis Selectable Air Prep Process Temperature 20° to 140°F (-7° to 60°C) Pneumatics: Temp. Compensation Automatic Directional Control Ambient Temperature -31° to 140°F (-35° to 60°C) Valves 30 PSI (2 bar) MAX Pressure Pneumatics: Enclosure Rating NEMA Type 6P, IP67, encapsulated, corrosion resistant & submersible, UV stable Cylinders Enclosure Material Polycarbonate Pneumatics: Strain Relief Material Santoprene Tubing Transducer Material Polyvinylidene Flouride Pneumatics: Cable Jacket Material Polyurethane Air Fittings Cable Type 9-conductor, shielded Appendix Cable Length 48 in (1.2m) Book 2 Process Mount 1 in MNPT (See accessories for installation fittings) 2 in MNPT (See accessories for installation fittings) Viton (included, replacement part number 204038) Viton (included, replacement part number 200128) Viton (included, replacement part number 200129) Terms and Mount Gasket Conditions Weight (lbs) 0.5 0.9 1.8 Classification General purpose Compliance CE, RoHS Agency Approvals cFMus * Dead band is the minimum distance the sensor must be mounted above the max liquid level. 1 If supply exceeds 28 VDC damage to the transmitter may occur. Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-9 Prices as of April 27, 2016. Check Web site for most current prices. EchoPod DL Series Multi-Function Ultrasonic Liquid Level Sensors Dimensions inches [mm]

DL14-00 DL24-00

When installing the 1 inch NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. DL34-00 Configuration The settings for the the DL series are configured with free WebCal software (downloadable from AutomationDirect Web site) and an LI99-1001 Fob USB adapter (purchased sepa- rately). BLAC K WHIT E GREEN RED

PART NO.: LI99-1001

See the end of the Ultrasonic Level Sensor Section for further details and Accessories

Wiring

Red - Power Blk - Power Return or 4-20mA Loop Output Wht - TX (Out) Grn - RX (In) Blu - Rly 1 Org - Rly 2 Yel - Rly 3 Pur - Rly 4 Brn - Rly Com

Book 2 (14.3) eLE-10 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

® Company PodView Digital Level Indicator Information

Drives

Overview Soft Starters

The PodView digital level indicator is a low cost general purpose indicator that Motors displays engineering units for level or volume when combined with an EchoPod ultrasonic sensor that has been configured with WebCal 6.0 / firmware 50.0 or Power higher. The LI40 can be field mounted for local indication as well as be used Transmission to make simple setting changes to the sensor. PodView displays sensor output Motion: Servos and can reconfigure sensor set points on the fly without needing to connect to and Steppers a PC. PodView shares power with the EchoPod sensor and does not require any Motor Controls additional separate power supply. Sensors: Features Proximity LI40-1001 Technical Specifications • Operates with all EchoPod level sensors compatible with WebCal 6.0 software / Sensors: firmware 50.0 or higher Photoelectric Price $195.00 • No separate power supply required LCD, 6-digit with 4 relay Sensors: Display Type indicators • Use PodView to make simple adjustments to EchoPods sensor settings Encoders

Display (Engineering Units) Level or Volume • Provides level indication up to 15 feet from sensor Sensors: Limit Switches Character Height 0.374 in (9.5 mm) • Corrosion resistant NEMA 4 / IP65 enclosure • No configuration required for the display. Simply wire the display directly to a Linearization per sensor configuration Sensors: programmed compatible EchoPod sensor Current User Interface Three button • Display can be transferred from sensor to sensor without any configuration changes to the display Sensors: Input EchoPod sensor family Pressure • Make quick setpoint changes without the need to connect sensor back to a PC Memory Non-volatile • Made in the USA Sensors: 12-28 VDC power shared with Temperature Supply Voltage sensor (EchoPod not to exceed 28 VDC) Agency Approvals Sensors: Level Operating Temperature -4°F to 140°F (-20°C to 60°C) • CE Cable Type 4-conductor, 22 AWG (0.33 mm²) Dimensions Sensors: Flow Cable Length 4 ft (1.2m)* inches [mm] Pushbuttons Cable Jack Material Polyurethane and Lights Enclosure Rating NEMA 4 (IP65) faceplate Stacklights Enclosure Material Polycarbonate Signal Enclosure Mount Panel Devices Button Material Silicon rubber Process Classification General purpose Relays and Weight (lbs) 0.6 Timers Compliance CE, RoHS Pneumatics: * Maximum distance between EchoPod sensor and PodView Air Prep display is 15 ft (4.5m) Pneumatics: Configuration Directional Control Valves The settings for the the EchoPod series are configured with free WebCal software (downloadable from AutomationDirect Pneumatics: Cylinders Web site) and an LI99-1001 Fob USB adapter (purchased Wiring separately). To be compatible with PodView the EchoPod Pneumatics: sensor must be configured with WebCal 6.0 / firmware 50.0 Tubing Red or higher. 4-20 mA Blk Pneumatics: load Air Fittings if applicable Wht Wht Grn Grn Appendix BLAC K WHIT E GREEN RED Blu Book 2 Org Yel Pur Terms and Brn EchoPod® PodView® Conditions

PART NO.: LI99-1001

Note: Maximum distance between EchoPod sensor and PodView display is 15 ft. (4.5m)

See the WebCal software catalog page in this section for further details

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-11 Prices as of April 27, 2016. Check Web site for most current prices. EchoSonic II LU Series Ultrasonic Liquid Level Transmitters

Overview Features The EchoSonic II LU Series ultrasonic liquid level transmit- • Continuous level measurement up to 9.8 ft (3m), 18 ft (5.5m), 26.2 ft (8m) or 32.8 ft (10m) ters provide continuous level measurement up to 9.8 ft (3m), • DSP auto adaptive filters enable plug and play operation 18 ft (5.5m), 26.2 ft (8m) or 32.8 ft (10m), with a 4-20mA optimizing signal output filtering and obstacle recognition signal output, and are configured via WebCal software. This • Configuration is fast and easy via WebCal software and USB adapter non-contact liquid level sensor is ideally suited for corrosive, • Narrow 2 inch or 3 inch beam width for applications with limited ultrapure, sticky or dirty liquids, and is broadly selected for bulk measurement space storage, dry tank, lift station and process tank level applications. • Short 4 inch or 8 inch dead band maximizes the measurable filling capacity of the tank • PVDF transducer and NEMA Type 6P polycarbonate enclosure for corrosive liquids, UV stable for outdoor use • Automatic temperature compensation for accurate measurement • Made in the USA Agency Approvals • cFMus Part No. LU27

Part No. LU23/28/29 LU20 Series Technical Specifications Model LU27-00 LU23-00 LU28-00 LU29-00 Price $497.00 $590.00 $683.00 $776.00 Range 4 in to 9.8 ft (10 cm to 3m) 8 in to 18.0 ft (20 cm to 5.5m) 8 in to 26.2 ft (20 cm to 8m) 8 in to 32.8 ft (20 cm to 10m) Accuracy ± 0.2% of range Resolution 0.019 in (0.5 mm) 0.039 in (1 mm) 0.079 in (2 mm) Sensing Dead Band* 4 in (10.2 cm) 8 in (20.3 cm) Beam Width 2 in (5.1 cm) 3 in (7.6 cm) Configuration WebCal Free Software and LI99-1001 Fob USB Adapter Memory Non-volatile Loop Supply Voltage 14 - 28 VDC1 Consumption 0.5W Loop Resist 500Ω @ 24 VDC Signal Output 4-20 mA, two-wire Signal Invert 4-20 mA or 20-4 mA Signal Fail-Safe 4 mA, 20 mA, 21 mA, 22 mA or hold last Process Temperature -4° to 140°F (-20° to 60°C) Temp. Compensation Automatic Ambient Temperature -31° to 140°F (-35° to 60°C) Pressure MWP = 30 PSI (2 bar) Enclosure Rating NEMA Type 6P, IP67, encapsulated, corrosion resistant & submersible, UV stable Enclosure Material Polycarbonate Transducer Material Polyvinylidene Flouride Cable Jacket Material Polyurethane Cable Type 4-conductor, shielded Cable Length 10 ft (3m) 1 in MNPT (See accessories for Process Mount installation fittings) 2 in MNPT (See accessories for installation fittings) Viton (included, replacement part Mount Gasket number 200128) Viton (included, replacement part number 200129) Weight (lbs) 1.4 1.8 1.8 1.8 Classification General purpose Compliance CE, RoHS Agency Approvals cFMus * Dead band is the minimum distance the sensor must be mounted above the max liquid level. 1 If supply exceeds 28 VDC damage to the transmitter may occur. Book 2 (14.3) eLE-12 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company EchoSonic II LU Series Ultrasonic Information Liquid Level Transmitters Drives Soft Starters Dimensions Motors inches [mm] Power Transmission

LU20 Series Motion: Servos and Steppers

Motor Controls

Sensors: Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Dimensions A B C D E F G H Flow LU27 2.71 [68.9] 4.00 [101.7] 4.10 [104.1] 3.10 [78.8] 2.75 [69.7] 1.70 [43.1] 1.10 [28.0] 1” MNPT LU23, 28, & 29 4.31 [109.6] 4.00 [101.7] 4.10 [104.1] 3.10 [78.8] 2.75 [69.7] 3.30 [83.8] 2.70 [68.7] 2” MNPT Pushbuttons and Lights When installing the 1” NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. Stacklights

Signal Wiring Devices LU27 LU23, LU28, LU29 Process Power - Red Return (4-20 mA loop output) - Black Power - Red Return (4-20 mA loop output) - Black Relays and Tx (out) - Green Rx (in) - White Timers Rx (in) - White Tx (out) - Green Shield Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Configuration Tubing Pneumatics: The settings for the the LU series Air Fittings

are configured with free WebCal BLAC K WHIT E GREEN RE D Appendix software (downloadable from Book 2 AutomationDirect Web site) and an LI99-1001 Fob USB adapter Terms and (purchased separately). Conditions PART NO.: LI99-1001

See the end of the Ultrasonic Level Sensor Section for further details and Accessories

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-13 Prices as of April 27, 2016. Check Web site for most current prices. WebCal Ultrasonic Level Sensor Software and USB Fob Adapter Overview System Requirements WebCal PC software is a utility program that allows users to • Windows XP, Vista, 7, 8 (WebCal 6.0 only) easily configure their EchoSonic II and EchoPod level trans- ® mitters, switches, and controllers. Download your free copy • 32 or 64 bit system of WebCal at www.AutomationDirect.com, and connect your • 1 USB® 2.0 Port sensor through the Fob USB adapter (LI99-1001). Develop your • 10 Mb hard disk space configuration using pre-programmed function menus as the tank • 256 Mb RAM graphic and set point fields automatically change to match your configuration. Then, input your level set point values and click the Write to Unit button. Your configuration will be downloaded Features into the sensor and verified in less than a second. Last, click • 169 configurations with pull-down menu selections the Wiring Diagram button to open a wiring schematic of your • Graphical interface lets you visualize your configuration configuration in PDF format. Print the document, disconnect the • Applicable level set point fields appear automatically sensor and wire it per the schematic. It’s that simple. • Installs and tests configuration in less than a second Configuration files can be named, saved, emailed, printed, • Available PDF wiring diagram for each configuration opened and used again under revision control. The advanced • Technical help menu with FAQs, tips and glossary feature page enables you to change the measurement signal, • Rapidly program sensors to the same configuration output filtering and invert relay states from N.O. to N.C. As • Save configuration files for future use or reference new software or firmware becomes available, they can be • Print wiring diagrams and configuration text files downloaded and updated through WebCal. • Email configuration files to other remote users • Made in the USA

WebCal Ultrasonic Level Sensor Software and USB Adapter Part No. Item Photo Description Quantity Weight (lbs) Price

Flowline Fob USB adapter, required for use with WebCal software to configure Flowline EchoPod and LI99-1001 EchoSonic II ultrasonic level sensors. 1 0.1 $42.00

Configuration software CD for Flowline EchoPod and EchoSonic II ultrasonic level sensors (also available WEBCAL as a free download from the AutomationDirect Web site). Requires an LI99-1001 Fob USB adapter (pur- 1 0.1 $9.00 chased separately).

EchoPod Configuration EchoSonic II Configuration

Book 2 (14.3) eLE-14 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

® Company Echotouch™, EchoSpan & Information EchoSwitch® Ultrasonic Liquid Drives Soft Starters Level Sensors Motors Power Overview Transmission Motion: Servos The Echotouch, EchoSpan and EchoSwitch are innovative and Steppers ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that fail due to contact with Motor Controls dirty, sticky and scaling media in small, medium and large capacity tanks. Applied in chemical, water and wastewater Sensors: applications, these general purpose non-contact sensors are Proximity available with single and multi-function capabilities including Sensors: continuous level measurement, switching and control. Photoelectric For input to a PLC or other controller, measurement outputs Sensors: include current, voltage and frequency. Models with three Encoders relays can be configured for level alarms and/or stand-alone level control such as automatic fill or empty functions using the Sensors: embedded level controller. Units are easily configured using Limit Switches built -in pushbuttons. Sensors: Current

Sensors: Pressure Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid Level Sensors General Specifications Sensors: Model LU20-5001-IS LU80-5101 LU81-5101 LU83-5101 LU84-5101 LU77-5004 LU74-5004 LU78-5004 Temperature Price $883.00 $646.00 $739.00 $832.00 $925.00 $739.00 $785.00 $832.00 Sensors: Type Echotouch EchoSpan EchoSwitch Level Intrinsically safe General Purpose (non-hazardous) Class Sensors: 6 in to 18 ft 4 in to 9.8 ft 8 in to 18 ft 8 in to 26.2 ft 12 in to 32.8 ft 4 in to 9.8 ft 8 in to 18 ft 8 in to 26.2 ft Flow Range (15 cm to 5.5m) (10 cm to 3m) (20 cm to 5.5m) (20 cm to 8m) (30 cm to 10m) (10 cm to 3m) (20 cm to 5.5m) (20 cm to 8m) Pushbuttons (1) SPDT relay, (2) SPST relays 4-20 mA, two-wire and Lights Output Types 4-20 mA, two-wire Install Vertical, top of tank Stacklights

Mounting 2 in MNPT 1 in MNPT 2 in MNPT 1 in MNPT 2 in MNPT Signal Relays No relay (1) SPDT relay, (2) SPST relays Devices

Configuration Pushbutton / LCD Process Ambient -4° to 140°F (-20° to 60°C) -40° to 160°F (-40° to 71°C) Relays and Temperature Timers Process -40° to 140°F -4° to 140°F (-20° to 60°C) Temperature (-40° to 60°C) Pneumatics: Air Prep 30 PSI (2 bar) @ 25°C, derated @ Pressure 1.667 psi (0.113 30 PSI (2 bar) MAX Pneumatics: bar) per °C above Directional Control 25°C (77°F) Valves

Pneumatics: Pushbutton Configuration Example - EchoSpan Display and Menu Cylinders Pneumatics: With no software or PC required, the Echotouch, EchoSpan, and Tubing EchoSwitch ultrasonic level sensors are easily configured using integral pushbuttons and LCD digital display. Configuration Pneumatics: Air Fittings parameters are organized in a simple menu structure so that parameter values are easily accessed and set or changed as Appendix needed. Parameters are stored in non-volatile memory so the Book 2 setting values are not lost when the sensor is powered down, Terms and allowing configuration before installation in the field. Conditions

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-15 Prices as of April 27, 2016. Check Web site for most current prices. Echotouch™ LU20 Ultrasonic Level Transmitter Overview Features The Echotouch LU20 ultrasonic level transmitter is • LCD digital display indicates level in inches or centimeters CSA approved for intrinsically safe applications. The • Polypropylene enclosure rated NEMA 4X / IP65 with two-wire ultrasonic transmitter provides non-contact rugged Kynar transducer measurement up to 18 ft (5.5m) and is ideally suited • Simple pushbutton calibration for all user setpoints for corrosive, slurry or waste liquids. The transmitter • Adjustable dead band and range filters eliminate is typically selected for atmospheric bulk storage, false echo returns day tank and waste sump applications located within a classified hazardous area. Media exam- Agency Approvals ples include diesel fuel and hydrochloric acid. The • CSA: Class I, Groups A, B, C & D; Class II, Groups E, F transmitter is calibrated in less than a minute using and G; Class III; T3C the LCD display, 4-button interface and intuitive Part No. LU20-5001-IS calibration menu. All user setpoints are held in non- volitile memory. In the event of acoustic signal loss, the transmitter will hold the current output at the user designated safe state. LU20-5001-IS Technical Specifications Price $883.00 Beam Cone Data Range 6 in to 18 ft (15 cm to 5.5m) The “Beam Cone” is the amount in which Accuracy w 0.25% of span in air the ultrasonic wave increases in diam- Resolution 0.125 in (3 mm) eter (Radius²) as the wave travels away Sensing Dead Band* 6 in (15 cm) from the sensor. This is important to note Beam Width 8° conical during installation to prevent objects in the Configuration Pushbutton / LCD tank from providing false echoes. Display Type LCD, 4-digit Display Units Inch or cm Depth Radius Radius (feet) (inches) (cm) Memory Non-volatile Loop Supply Voltage 12 - 32 VDC 1 1.2 3.1 Loop Resistance 600Ω max @ 24 VDC, 900Ω max @ 32 VDC 3 2.9 7.3 Signal Output 4-20 mA, two-wire 5 4.6 11.6 Signal Invert 4-20 mA or 20-4 mA 7 6.2 15.9 Loop Fail-Safe 4 mA, 22 mA or hold last 9 7.9 20.1 Calibration digital, pushbutton, LCD 11 9.6 24.4 Process Temperature -4° to 140°F (-20° to 60°C) 13 11.3 28.7 Ambient Temperature -4° to 140°F (-20° to 60°C) 15 13.0 32.9 17 14.6 37.2 Pressure 30 psi @ 77°F, derated @ 1.667 psi per 1.8°F above 77°F (2 bar @ 25°C, derated @ 0.113 bar per 1°C above 25°C) 19 16.3 41.3 Enclosure Rating NEMA 4X (IP65) Installed Height 5.1 in (13 cm) above tank process mount Enclosure Material Polypropylene, UL94VO Transducer Material Polyvinylidene Flouride, Kynar Process Mount 2 in MNPT (See accessories for installation fittings) Terminal Block 26-12 AWG (tighten torque, 0.4 Nm), removable Conduit Entrance Single, 1/2 in FNPT Weight (lbs) 2.2 Classification Intrinsically safe (Haz-Loc) CSA: Class I, Groups A, B, C & D; Class II, Groups E, F and G; Class III; T3C, Agency Approvals CE, RoHS

I.S. Parameters CSA Vmax < 32.0 V; Imax < 130 mA; Ca = 0 µF; La = 0 µH Certificates CSA: LR79326-10 D CE: EN 50082-2 immunity, EN 55011 emission Compliance (Recommended I.S. barrier MTL7706+) * Dead band is the minimum distance the sensor must be mounted above the max liquid level. R

Book 2 (14.3) eLE-16 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Echotouch™ LU20 Ultrasonic Information Level Transmitter Drives Soft Starters

Wiring Typically loop Dimensions Motors powered indicator

(+) DC Power Power (-) inches [mm] Transmission Echotouch™ Supply 12-32 VDC Motion: Servos + - - + and Steppers Ultrasonic Level Transmitter

Motor Controls MENU

SET Sensors: Proximity

Sensors: Photoelectric (+) (-) Echotouch™ Sensors: Encoders

Ultrasonic Level Transmitter Sensors: Limit Switches

MENU Sensors: SET C Current

Sensors: Control Drawing Pressure Sensors: Temperature NON-HAZARDOUS LOCATION HAZARDOUS LOCATION Class I, Div I, Groups A, B, C & D Sensors: Model LU20 Level I.S. Barrier Ultrasonic Vdc ≤ 32.0 V Level Transmitter Isc ≤ 130 mA Ca ≥ 0 µF Sensors: La ≥ 0 µH Vmax = 32.0 V Flow

Supply Imax = 130 mA Ci ≈ 0 µF Li ≈ 0 µH Pushbuttons and Lights

Stacklights

Control drawing for the LU20-5001-IS ultrasonic level transmitter Signal approved under the entity concept as an I.S. apparatus Devices Control Drawing: LU20CD Rev. 7-24-97 Process

Relays and CSA Label Temperature and Resistance Timers

Derating Charts Pneumatics: ® LR79326-10 Air Prep MaximumTemperature/Voltage Derating MaximumTemperature/Voltage Derating C)

NRTL/C ° C) ° Continuous 20 mA Curve (LU20-50_1) Continuous 20 mA Curve (LU20-50_1-IS) Pneumatics: 100 Intrinsically Safe/ 100 Directional Control Securite Intrinseque Unacceptable Unacceptable Valves Exia 80 Range 80 Range emperature ( emperature ( 60 60 T For use in T Pneumatics: Hazardous Locations: 40 Acceptable 40 Acceptable Cylinders Class I, Groups A, B, C & D Range Range Class II, Groups E, F & G 20 20 Class III Pneumatics: Temperature Code: T3C 0 0 Tubing

Ambient Sensor 12 16 20 24 28 32 36

Ambient Sensor 12 16 20 24 28 32 36 Intrinsically Safe when used with Operating Voltage (VDC) Operating Voltage (VDC) an approved I.S. barrier. Entity Pneumatics: Parameters Flowline 4 or 20 mA Flowline 4 or 20 mA Air Fittings LU20-50_1 Electrical Loading Limits LU20-50_1-IS Electrical Loading Limits Vmax = 32.0 VDC 1,000 1,000 Imax = 130 mA Appendix Ci = 0 µF Unacceptable Unacceptable Li = 0 µH 750 Range 750 Range Book 2

Warning: Suitable for Class I, Groups A, B, 500 500 C & D; Class II, Groups E, F & G; Class III, Terms and T3C; when used with an approved I.S. Conditions Acceptable Acceptable barrier. Substitution of components may 250 Range 250 Range impair intrinsic safety LU20-50X1-IS requirements for Intrinsically Safe operation 0 0 Max. Series Resistance (Ohms) Max. Series Resistance (Ohms) 12 16 20 24 28 32 36 12 16 20 24 28 32 SupplyVolyage (VDC) Supply Volyage (VDC)

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-17 Prices as of April 27, 2016. Check Web site for most current prices. EchoSpan® LU Series Ultrasonic Level Transmitters Overview Features The EchoSpan LU series ultrasonic level transmitters provide • 4 measurement ranges from 9.8 ft (3m) to 32.8 ft (10m) continuous level measurement up to 32.8 ft (10m) with a 4-20 mA • Configuration is simple via integral pushbutton display module signal output, and is configured via its integral pushbutton display • LCD display indicates level in inches, centimeters and percentages module. This non-contact liquid level sensor is ideally suited for • Narrow 2 inch or 3 inch beam width for applications with limited corrosive, ultrapure, sticky or dirty liquids, and is broadly selected measurement space for bulk storage, day tank, lift station and process tank level • Fail-safe intelligence and diagnostic feedback for simple applications. troubleshooting • PVDF transducer and NEMA 4X / IP65 polycarbonate enclosure for corrosive liquids • Automatic temperature compensation for accurate measurement • Made in the USA

Part No. LU80-5101 Part No. LU81-/83/84-5101 LU80 Series Technical Specifications Model LU80-5101 LU81-5101 LU83-5101 LU84-5101 Price $646.00 $739.00 $832.00 $925.00 Range 4 in to 9.8 ft (10 cm to 3m) 8 in to 18 ft (20 cm to 5.5m) 8 in to 26.2 ft (20 cm to 8m) 12 in to 32.8 ft (30 cm to 10m) Accuracy ± 0.2% of range Resolution 0.019 in (0.5 mm) 0.039 in (1 mm) 0.078 in (2 mm) Sensing Dead Band* 4 in (10 cm) 8 in (20 cm) 12 in (30 cm) Beam Width 2 in (5.1 cm) 3 in (7.6 cm) Configuration Pushbutton / LCD Memory Non-volatile Display Type LCD, 6-digit Display Units Inch, cm and percent Supply Voltage 12 - 28 VDC** Loop Resistance 500Ω @ 24 VDC Signal Output 4-20 mA, two-wire Signal Invert 4-20 mA or 20-4 mA Signal Fail-Safe 4 mA, 20 mA, 21 mA, 22 mA or hold last Terminal Block 26-12 AWG (tighten torque, 0.5 Nm) Process Temperature -4° to 140°F (-20° to 60°C) Temp. Compensation Automatic Ambient Temperature -40° to 160°F (-40° to 71°C) Pressure 30 PSI (2 bar) MAX Enclosure Rating NEMA Type 4X (IP65) Enclosure Material Polycarbonate Enclosure Hardware Brass & stainless steel Enclosure Vent Water tight membrane Conduit Entrance Dual, 1/2 in FNPT Transducer Material Polyvinylidene Flouride 1 in MNPT (See accessories for Process Mount installation fittings) 2 in MNPT (See accessories for installation fittings)

Viton (included, replacement part Mount Gasket number 200128) Viton (included, replacement part number 200129) Weight (lbs) 1.5 1.9 Classification General purpose Compliance CE, RoHS * Dead band is the minimum distance the sensor must be mounted above the max liquid level. ** If supply exceeds 28 VDC damage to the transmitter may occur.

Book 2 (14.3) eLE-18 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

® Company EchoSpan LU Series Ultrasonic Information Level Transmitters Drives Soft Starters

Dimensions Configuration Motors inches [mm] The transmitter is configured using Power Transmission LU80 Series the three buttons (UP, DOWN and SELECT) and the transmitter’s LCD Motion: Servos on the transmitters face. and Steppers

More information about configuring Motor Controls the LU series sensors can be found at www.AutomationDirect.com Sensors: Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Dimensions A B C D E F G H Pushbuttons LU80 3.90 [99.1] 4.10 [104.1] 5.20 [132.1] 3.10 [78.8] 2.80 [71.1] 1.90 [48.3] 1.25 [31.8] 1 in MNPT and Lights LU81, 83 & 84 5.50 [139.6] 4.10 104.1] 5.20 [132.1] 3.10 [78.8] 2.80 [71.1] 3.40 [86.4] 2.70 [68.6] 2 in MNPT Stacklights When installing the 1 inch NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. Signal Devices Wiring Process Relays and Typical Loop Powered Display Typical Generic PLC Timers

Pneumatics: Air Prep

Pneumatics: C Directional Control 4 Valves 3 2 Pneumatics: Cylinders 1

Pneumatics: Tubing

Pneumatics: EchoSpan Air Fittings

Appendix EchoSpan Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-19 Prices as of April 27, 2016. Check Web site for most current prices. EchoSwitch® LU Series Ultrasonic Level Sensors Overview Features • 3 level detection ranges: 9.8 ft (3m), 18.0 ft (5.5m) and 26.2 ft (8m) The EchoSwitch LU series of ultrasonic level sensors are configured • Configuration is simple via integral pushbutton display module via the integral pushbutton display module, provides continuous level detection up to 26.2 ft (8m) with 3 programmable relays • Three programmable relays for switch, pump control and fail-safety

for level switch or level control functions and a 4-20 mA output. - 1 pump or valve with 2 alarms Each relay can be configured on a single setpoint (high level alarm - 2 pumps (lead-lag) with 1 alarm or low level alarm) or latched on two setpoints for automatic fill - 2 pumps (duplexing) with 1 alarm or empty in simplex (one pump or valve), duplex (two pumps) or - 3 independent outputs triplex (three pumps) level control modes with selectable time delay • 4-20 mA output can be used to provide local or remote level detection and fail-safe logic. The embedded level controller can lower cost • LCD display indicates level height in engineering units and relay status by replacing external control hardware. These non-contact level • Narrow 2 inch or 3 inch beam width for applications with limited mea- sensors are ideally suited for corrosive, sticky or dirty liquids, and surement space are broadly selected for pump lift station, sump and day tank level • Short 4 inch or 8 inch dead band maximizes the measureable filling applications. capacity of the tank • PVDF transducer and NEMA 4X / IP65 polycarbonate enclosure for cor- rosive liquids • Automatic temperature compensation • Made in the USA Features LU70 Series Technical Specifications Model LU77-5004 LU74-5004 LU78-5004 Price $739.00 $785.00 $832.00 Range 4 in to 9.8 ft (10 cm to 3m) 8 in to 18 ft (20 cm to 5.5m) 8 in to 26.2 ft (20 cm to 8m) 0.25 in (6.35 mm) Part No. LU77-5004 Repeatability Loop Output 4-20 mA isolated, sinking 12 to 28 VDC** Loop Resistance 500Ω max @ 24 VDC Sensing Dead Band* 4 in (10 cm) 8 in (20 cm) Beam Width 2 in (5.1 cm) 3 in (7.6 cm) Configuration Pushbutton / LCD Memory Non-volatile Display Type Level and relay status, 6 character Display Units Inch, cm, percent, feet or meter LCD Indication Level and relay status Supply Voltage 95 to 250 VAC (separate 12-28 VDC power supply required for 4-20 mA loop output) Power 20W @ 120 VAC Contact Type Relay 1, SPDT relay; Relay 2 & 3, SPST, N.O., all commons connected together Contact Rating 2A @ 30 VDC max / 2A @ VAC max Part No. LU74-5004 Terminal Block 22-14 AWG (tighten torque, 0.5 Nm) Contact Fail-Safe Programmable / selectable Process Temperature -4° to 140°F (-20° to 60°C) Temp. Compensation Automatic Ambient Temperature -40° to 160°F (-40° to 71°C) Pressure 30 PSI (2 bar) MAX Enclosure Rating NEMA Type 4X (IP65) Enclosure Material Polycarbonate Transducer Material Polyvinylidene Flouride Enclosure Hardware Brass & stainless steel Enclosure Vent Water tight membrane Conduit Entrance Dual, 1/2” FNPT 1 in MNPT (See accessories for Part No. LU78-5004 Process Mount installation fittings) 2 in MNPT (See accessories for installation fittings) Viton (included, replacement part num- Mount Gasket ber 200128) Viton (included, replacement part number 200129) Weight (lbs) 1.5 2.0 Classification General purpose Compliance CE, RoHS * Dead band is the minimum distance the sensor must be mounted above the max liquid level.

Book 2 (14.3) eLE-20 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

® Company EchoSwitch LU Series Ultrasonic Information Level Sensors Drives Soft Starters Dimensions Configuration Motors inches [mm] The transmitter is configured using Power Transmission LU70 Series the three buttons (UP, DOWN and SELECT) and the transmitter’s LCD Motion: Servos on the transmitters face. and Steppers

More information about configuring Motor Controls the LU series sensors can be found at Sensors: www.AutomationDirect.com Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow Dimensions A B C D E F G H Pushbuttons LU74 & LU78 5.50 [139.6] 4.10 [104.1] 5.20 [132.1] 3.10 [78.8] 2.80 [71.1] 3.50 [89.0] 2.70 [89.0] 2” MNPT and Lights LU77 3.90 [99.1] 4.10 [104.1] 5.20 [132.1] 3.10 [78.8] 2.80 [71.1] 1.90 [48.3] 1.25 [31.8] 1” MNPT Stacklights When installing the 1” NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. Signal Devices

Wiring Process

Relay Application Loop Application Relays and Timers

Pneumatics: User Supplied Air Prep 95 to 250 VAC Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Note: Separate 12-28 VDC power Appendix Note: Isolate power to instrument from power to load (pumps, etc.) as supply is required for loop output. Book 2 much as possible by running power to the sensor directly from main power source. All relay commons are internally connected. Terms and Conditions

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-21 Prices as of April 27, 2016. Check Web site for most current prices. Ultrasonic Liquid Level Sensor Accessories Ultrasonic Liquid Level Sensor Accessories Part No. Item Photo Description Quantity Weight Price Flowline PodView general purpose digital indicator, displays tank level or volume and sensor relay status, 6-digit LCD display with four relay status indicators, 3-button user interface, polycarbonate panel mount 1 0.6 $181.00 LI40-1001 enclosure with NEMA 4 (IP65) faceplate, 6-foot (1.8-meter) 22AWG 4-conductor cable, compatible with any Flowline EchoPod series ultrasonic level sensor with firmware V50 or later

Flowline side mount bracket, 2 inch NPT female threads, polypropylene (PP), for use with Flowline DL34, 1 0.4 $32.00 LM50-1001 LU20, LU23, LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level sensors

Flowline side mount bracket, 2 inch NPT female threads, polypropylene (PP), and 2 inch NPT male x 1 LM50-1001-1 inch NPT female reducer bushing (PVC), for use with Flowline DL14, DL24, DS14, DL10, DX10, LU27, 1 0.6 $41.00 LU77, and LU80 series ultrasonic level sensors

Flowline reducer bushing, 2 inch NPT male x 1 inch NPT female threads, PVC, for use with Flowline DL14, 1 0.2 $13.00 LM52-1400 DL24, DS14, DL10, DX10, LU27, LU77, and LU80 series ultrasonic level sensors

Flowline reducer bushing, 3 inch NPT male x 2 inch NPT female threads, PVC, for use with Flowline DL34, 1 0.6 $29.00 LM52-2400 LU20, LU23, LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level sensors

Flowline low-profile bulkhead fitting, 1 inch NPT female x slip socket, with mounting nut, PVC, for use with 1 0.5 $41.00 LM52-1890 Flowline DL14, DL24, DS14, DL10, DX10, LU27, LU77 and LU80 series ultrasonic level sensors

Flowline low-profile bulkhead fitting, 2 inch NPT female x slip socket, with mounting nut, PVC, for use LM52-2890 with Flowline DL34, LU20, LU23, LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level 1 1.2 $69.00 sensors

Flowline mounting flange, 1 inch NPT female threads, PVC, for use with Flowline DL14, DL24, DS14, 1 0.5 $41.00 LM52-1850 DL10, DX10, LU27, LU77, and LU80 series ultrasonic level sensors

Flowline mounting flange, 2 inch NPT female threads, PVC, for use with Flowline DL34, LU20, LU23, 1 1.0 $60.00 LM52-2850 LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level sensors

Replacement mounting gasket, for use with Flowline DL14, DL10, DX10, and DS14 series ultrasonic level 1 0.1 $5.00 204038 sensors

Replacement mounting gasket, for use with Flowline DL24, LU27, LU77, and LU80 series ultrasonic level 1 0.1 $9.00 200128 sensors

Replacement mounting gasket, for use with Flowline DL34, LU23, LU28, LU29, LU74, LU78, LU81, LU83, 1 0.1 $13.00 200129 and LU84 series ultrasonic level sensors

When installing the 1” NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed. Dimensions inches [mm] LM50-1001 LM50-1001-1

Book 2 (14.3) eLE-22 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Ultrasonic Liquid Level Sensor Information Accessories Drives Soft Starters Dimensions Motors inches [mm] Power LM52-1400 LM52-2400 Transmission

Motion: Servos and Steppers

Motor Controls

Sensors: Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: LM52-1890 LM52-2890 Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons and Lights

Stacklights

Signal Devices

Process

Relays and Timers LM52-1850 LM52-2850 Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-23 Prices as of April 27, 2016. Check Web site for most current prices. Switch-Tek™ LU10 Ultrasonic Level Switches Overview CSA approved for hazardous environments, the intrinsically safe ultra- sonic point level switch provides reliable liquid level detection of chem- ical, solvent, hydrocarbon and petroleum based liquids with a 1A relay output. The submersible polypropylene (PP) liquid level sensor is universally mounted through the tank wall or inside the tank as a high level alarm or low level alarm. Features • CSA approved intrinsically safe for use in hazardous environments Part No. LU10-1305 • Submersible polypropylene (PP) sensor and cable • 60VA relay selectable NO or NC via power supply wiring polarity Part No. LU10-1405 • Compatible with Switch-Pak installation fittings • Able to mount through the side wall or top wall of tank Switch-Tek™ LU10 Technical Specifications • Made in the USA Model LU10-1305 LU10-1405

Price $265.00 $274.00 IP 68 Weight (lb) 0.7 0.7 Insertion Length 0.7 in [17.8 mm] 2.1 in [53.3 mm] Dimensions Orientation Universal inches [mm] Accuracy w1mm [0.04 in] in water Repeatability w0.5 mm [0.02 in] in water Supply Voltage 12-36 VDC Consumption 25mA maximum Contact Type (1) SPST relay General purpose: 60VA @ 1A (125VAC Contact Rating max) Intrinsically safe: 32VDC @ 0.5 A Part No.LU10-1305 Contact Output Selectable NO / NC Process Temp. -40°F to 176°F [-40°C to 80°C] 150psi [10bar] @ 25°C, derated @ Pressure 1.667 psi [0.113 bar] per °C above 25°C Sensor Rating NEMA 6 (IP68) Sensor Material PP (polypropylene) Cable Jacket Material PP (polypropylene) Part No.LU10-1405 Cable Type 4-conductor, #22AWG, shielded See our website www.AutomationDirect.com for complete Engineering drawings. Cable Length 10ft (3m) Process Mount 3/4” NPT Compatible Products Classification Intrinsically safe (Haz-Loc) CSA: Class 1, Groups A, B, C, & D; Class II Switch-Pro™ Switch-Pro™ Switch-Pak™ Groups E, F & G; Class III Remote Level Controllers Junction Box and Strobe Installation Fittings Agency Approvals* EEx: Class 1, Division 1, Groups A, B, C, & D; EEx ib IIC T6 CSA: Vmax = 32V, Imax = 300mA, Intrinsically Safe (I.S.) Pmax = 1.3 W; Ci = 0µF, Li = 0µH LM45-7001-0000 Parameters EEx: Ui = 32V; li = 300mA; Pi = 1.3 W; LC06-1001 LC06-1001 Ci = 0µF; Li = 0µH LCXX with LC09-1004 LM45-1001-12 and LM90-1001 Certificates* CSA: LR 79326; EEx: LCIE 01.E6048 X Compliance* CE (EN61326, EN61010-1) See the Switch-Pro® LCXX and Accessories pages at the end of the section for further details and pricing. * To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page at www.AutomationDirect.com

Book 2 (14.3) eLE-24 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Switch-Tek™ LU10 Ultrasonic Information Drives

Level Switches Soft Starters Intrinsically Safe (Haz-Loc) Wiring Information Motors

Power Transmission Models LU10: Motion: Servos The LU10 level switch has been approved for use in Class I, and Steppers Groups A, B, C & D; UNDER CERTIFICATE NUMBER LR 79326- Motor Controls 4. The Entity parameter for the LU10 are: Sensors: Proximity Vmax = 32 VDC Sensors: Imax = 0.5 A Photoelectric Ci = 0 µF Sensors: Li = 0 mH Encoders

Sensors: Intrinsically Safe Control Drawing: Limit Switches

NON-HAZARDOUS LOCATION HAZARDOUS LOCATION Sensors: Class I, Groups A, B, C & D Current Class II, Groups E, F & G Sensors: Class III Pressure Associated Sensor Models Sensors: Equipement Temperature (see notes 1 and 4) LU10 Sensors: Level

Red Wire Entity Parameters Sensors: Vmax = 32V Flow Black Wire Imax = 0.5A Pushbuttons Ci = 0 and Lights Shield Li = 0 Stacklights Notes: Signal 1. CSA certified associated equipment with entity parameters. Devices max oc max sc i cable a i cable a 2. V ≥ V , I ≥ I , C + C ≤ C ., L + L ≤ L . Process 3. Installation should be in accordance with CEC Part I, or Relays and NFPA 70. Timers 4. Associated equipment must be installed per manufacturers Pneumatics: instructions Air Prep Sensor Drawing: LSD1 Rev. B 10-01-02 Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/level-switches Level Sensors eLE-25 Prices as of April 27, 2016. Check Web site for most current prices. Switch-Tek™ LU10 Ultrasonic Level Switches Intrinsically Safe (Haz-Loc) Wiring Information

Models LU10: The LU10 level switch has been approved for use in Class I, Division 1, Groups A, B, C & D; EEx ib IIC T6; UNDER CERTIFICATE NUMBER LCIE 01.E6048X. The Entity parameter for the LU10 are: North America Europe Vmax = 32 VDC Ui = 32 VDC Imax = 0.5 A Ii = 0.5 A Pmax = 1.3 W Pi = 1.3 W Ci = 0 µF Ci = 0 µF Li = 0 µH Li = 0 µH Intrinsically Safe Control Drawing: NON-HAZARDOUS LOCATION HAZARDOUS LOCATION Class I, Division1, Groups A,B,C,D EEx ib IIC T6

Associated Sensor Models Equipment LU10-___5 Entity Parameters: Entity Parameters: North America North America Voc ≤ Vmax Vmax = 32V Isc ≤ Imax Red Wire Imax = 300 mA Ca ≥ Ci +Ccable Pmax = 1.3 W La ≥ Li +Lcable Black Wire Ci = 0 µF Europe Li = 0 µH Shield Uo ≤ Ui Europe Io ≤ Ii Ui = 32V Co ≥ Ci +Ccable Ii = 300 mA Lo ≥ Li +Lcable Pi = 1.3 W Ci = 0 µF Li = 0 µH

Sensor Drawing: U1090 0 Sheet 1 of 2 Rev. B 4-02-01

NON-HAZARDOUS LOCATION HAZARDOUS LOCATION Class I, Division1, Groups A,B,C,D EEx ib IIC T6

Associated Equipment Sensor Models Red Wire LU10-___5 Entity Parameters for 12-32 Lines: Black Wire Entity Parameters for 12-32 Lines: Voc ≤ Vmax, Uo ≤ Ui Vmax = 32V, Ui = 32V Isc ≤ Imax, Io ≤ Ii Shield Imax = 300 mA, Ii = 300 mA Ca ≥ Ci +Ccable, Co ≥ Ci +Ccable Pmax = 1.3 W, Pi = 1.3 W La ≥ Li +Lcable, Lo ≥ Li +Lcable Ci = 0 µF,Ci = 0 µF Li = 0 µH, Li = 0 µH Entity Parameters for Switch Outputs: Voc ≤ Vmax, Uo ≤ Ui Green Wire Entity Parameters for Switch Outputs: Isc ≤ Imax, Io ≤ Ii Vmax = 32V, Ui = 32V Ca ≥ Ci +Ccable, Co ≥ Ci +Ccable White Wire Imax = 500 mA, Ii = 500 mA La ≥ Li +Lcable, Lo ≥ Li +Lcable Pmax = 1.3 W, Pi = 1.3 W Ci = 0 µF,Ci = 0 µF Li = 0 µH, Li = 0 µH

Notes: PARAMETERS DEPEND ON OUTPUT TYPE 1. Installation should be in accordance with CEC Part 1, or NFPA 70. Sensor Drawing: U10900 2. Associated Equipment shall be CSA certified with entity parameters Sheet 2 of 2 connected in accordance with manufacturers instructions. Rev. B 4-02-01

Book 2 (14.3) eLE-26 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Switch-Tek™ LZ12 Vibration Information Drives Fork Level Switch Soft Starters Overview Motors

The general purpose vibration point level switch provides reliable liquid Power level detection of dirty liquids such as those with light to medium coating, Transmission scaling or foaming characteristics with a 1A relay output. Media examples Motion: Servos include wastewater, diluted caustic soda and light weight oil. For optimum and Steppers performance, the liquid level switch automatically adjusts for coating build up and, if necessary, outputs a proactive maintenance alarm to request Motor Controls

cleaning. The submersible Ryton® liquid level sensor is universally mounted Sensors: through the tank wall or inside the tank as a high level or low level alarm. Proximity

Sensors: Features Photoelectric • Automatic coating adjustment optimizes sensor performance Sensors: • Submersible Ryton® sensor with polypropylene (PP) cable for corrosive liquids Encoders Part No. LZ12-1405 • Coating alarm proactively alerts user when cleaning is required Sensors: • 60VA relay selectable NO or NC via power supply wiring polarity Limit Switches Switch-Tek LZ12 Technical Specifications • Compatible with Switch-Pak installation fittings Sensors: Model LZ12-1405 • Ideal for coating/scaling liquids Current Price $283.00 • Mounts through side wall or top wall of tank Sensors: • Made in the USA Pressure Weight (lb) 0.7 Sensors: Insertion Length 2.3 in [57mm] Temperature IP Orientation Universal 68 Sensors: Level Accuracy w1mm [0.04 in] in water Sensors: Repeatability w0.5 mm [0.02 in] in water Dimensions Flow 12-30 VDC Supply Voltage Pushbuttons inches [mm] and Lights Consumption 25mA maximum Contact Type (1) SPST relay Stacklights

Contact Rating 60VA, 1A maximum (125VAC max) Signal Devices Contact Output Selectable NO / NC Process Maint. Alarm NPN transistor, 10mA maximum Process Temp. -40°F to 176°F [-40°C to 80°C] Relays and Timers Part No.LZ12-1405 150psi [10bar] @ 25°C, derated @ Pressure 1.667 psi [0.113 bar] per °C above 25°C See our website www.AutomationDirect.com Pneumatics: for complete Engineering drawings. Air Prep Sensor Rating NEMA 6 (IP68) Pneumatics: Ryton® (glass filled) Directional Control Sensor Material Compatible Products Valves

Cable Grommet Material Viton® ™ Switch-Pro™ Switch-Pro™ Switch-Pak Pneumatics: Remote Level Controllers Junction Box and Strobe Installation Fittings Cable Jacket Material PP (polypropylene) Cylinders

Cable Type 5-conductor, #24AWG, shielded Pneumatics: Tubing Cable Length 10ft (3m) LM45-7001-0000 Pneumatics: 3/4” NPT Process Mount LC06-1001 LC06-1001 Air Fittings LCXX with LC09-1004 LM45-1001-12 Classification General purpose and LM90-1001 Appendix Book 2 Compliance* CE (EN61326, EN61010-1) See the Switch-Pro® LCXX and Accessories pages at the end of the section for further details and pricing. * To obtain the most current agency approval information, see the Agency Terms and Conditions Approval Checklist section on the specific part number’s web page at www.AutomationDirect.com

Book 2 (14.3) www.automationdirect.com/level-switches Level Sensors eLE-27 Prices as of April 27, 2016. Check Web site for most current prices. Switch-Tek™ LP15 Capacitance Level Switch Overview The general purpose guard capacitance point level switch provides reli- able high or low liquid level detection of water based conductive liquids with light coating, crystalizing or scaling characteristics with a 1A relay output. Media examples include copper sulfate and brine. The RF guard circuit eliminates the coating signal path between the active and reference electrodes. The submersible polypropylene (PP) liquid level sensor is univer- sally mounted through non-metallic tank walls or inside the tank as a high level or low level alarm. Features • Guard circuit optimized performance in coating type media • Submersible polypropylene (PP) sensor body and cable for corrosive liquids Part No. LP15-1405 • 60VA relay selectable NO or NC via power supply wiring polarity • Compatible with Switch-Pak installation fittings Switch-Tek LP15 Technical Specifications • Ideal for side wall or top mount Model LP15-1405 • Ideal for coating liquids • Great for waste water applications Price $246.00 • Made in the USA Weight (lb) 0.7 IP 68 Insertion Length 2.6 in [67mm] Orientation Universal Accuracy w1mm [0.04 in] in water Dimensions Repeatability w0.5 mm [0.02 in] in water inches [mm] Dielectric Range >20 constants

Conductive range >100µ Ω Supply Voltage 12-36 VDC Consumption 25mA maximum Contact Type (1) SPST relay Contact Rating 60VA, 1A maximum (125VAC max)

Contact Output Selectable NO / NC Part No.LP15-1405 See our website www.AutomationDirect.com for complete Engineering drawings. Maint. Alarm NPN transistor, 10mA maximum Process Temp. -40°F to 176°F [-40°C to 80°C] Compatible Products 150psi [10bar] @ 25°C, derated @ Pressure 1.667 psi [0.113 bar] per °C above 25°C Switch-Pro™ Switch-Pro™ Switch-Pak™ Remote Level Controllers Junction Box and Strobe Installation Fittings Sensor Rating NEMA 6 (IP68) Sensor Material PP (polypropylene) PP (polypropylene) Cable Jacket Material LM45-7001-0000 Cable Type 4-conductor, #22AWG, shielded LC06-1001 LC06-1001 LCXX with LC09-1004 LM45-1001-12 Cable Length 10ft (3m) and LM90-1001 Process Mount 3/4” NPT See the Switch-Pro® LCXX and Accessories pages at the end of the section for further details and pricing. Classification General purpose Compliance* CE (EN61326, EN61010-1) * To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page at www.AutomationDirect.com

Book 2 (14.3) eLE-28 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Switch-Tek™ LV10 Buoyancy Information Drives Level Switch Soft Starters Overview Motors

The general purpose buoyancy point level switch provides reliable liquid Power level detection of relatively clean water and chemical solutions. Media Transmission

examples include boric acid and ultrapure water. The baffle body elimi- Motion: Servos nates level switch chatter caused by turbulence. The submersible polypro- and Steppers pylene (PP) liquid level sensor is mounted vertically inside the tank as a high level or low level alarm. Motor Controls Sensors: Features Proximity • Baffle body and stabilized float dampen out switch chatter Sensors: Photoelectric • Submersible polypropylene (PP) sensor and cable for corrosive liquids • 15VA dry contact (reed switch) selectable NO or NC state Sensors: Encoders Part No. LV10-1301 • Compatible with Switch-Pak installation fittings • Ideal for water and waste applications Sensors: Limit Switches • Float can wire directly to PLC/SCADA or controller Switch-Tek LV10 Technical Specifications • Cage helps protect from debris Sensors: Current Model LV10-1301 • Made in the USA

IP Sensors: Price $111.00 68 Pressure

Weight (lb) 0.7 Sensors: Temperature Insertion Length 4.3 in [108mm] Dimensions Sensors: Orientation w20° vertical inches [mm] Level

Accuracy w2mm [0.08 in] in water Sensors: Flow Repeatability w1mm [0.04 in] in water Pushbuttons Specific Gravity 0.8 minimum and Lights Contact Type (1) SPDT reed Stacklights

Contact Rating 15VA, 0.25 A maximum (125VAC max) Signal Devices Contact Output Selectable NO / NC See our website www.AutomationDirect.com Part No.LV10-1301 Process Process Temp. -40°F to 194°F [-40°C to 90°C] for complete Engineering drawings. Relays and 25psi [2bar] @ 25°C, derated @ Timers Pressure 1.667 psi [0.113 bar] per °C above 25°C Compatible Products Pneumatics: Switch-Pro™ Switch-Pro™ Switch-Pak™ Air Prep Sensor Rating NEMA 6 (IP68) Remote Level Controllers Junction Box and Strobe Installation Fittings PP (polypropylene) Pneumatics: Sensor Material Directional Control Valves Cable Jacket Material PP (polypropylene) LM45-7001-0000 Pneumatics: Cable Type 3-conductor, #22AWG, shielded LC06-1001 LC06-1001 Cylinders LCXX with LC09-1004 when used LM45-1001-12 with and LM90-1001 Cable Length 10ft (3m) Pneumatics: LM45-1001-12 or Tubing Process Mount 3/4” NPT LM45-7001-0000 See the Switch-Pro® LCXX and Accessories pages at the end of Pneumatics: Classification General purpose the section for further details and pricing. Air Fittings

Compliance* CE (EN61326) Appendix Book 2 * To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page at Terms and www.AutomationDirect.com Conditions

Book 2 (14.3) www.automationdirect.com/level-switches Level Sensors eLE-29 Prices as of April 27, 2016. Check Web site for most current prices. Switch-Pro™ Remote Level Controllers Overview CSA approved, the Switch-Pro general purpose level controllers are offered in three configurations for alarms, pump and valve control. The LC40 accepts one level sensor input and provides one 10A relay for high level or low level alarm. The LC41 accepts two level sensor inputs and provides one Part No. LC40-1001 latching 10A relay for automatic fill or empty control. The LC42 accepts three level sensor Part No. LC41-1001 inputs with one latching 10A relay output for automatic fill or empty control, and a second non-latching 10A relay for high level or low level alarm.

Part No. LC42-1001 Features • Fail-safe relay control of pumps or valves with 0-60 second delay • Mounts easily in control panel • Easy setup with LED indicators for sensor, power and relay status • Connects to any Flowline level switch • 35mm DIN rail mount or panel mount polypropylene (PP) enclosure • Interfaces directly with any horn, buzzer, valve, etc... with removable terminal strips • Use LC41, LC42 version for automatic fill/empty operations • Invert switch changes relay state from NO to NC without rewiring • Made in the USA

Switch-Pro LC Series Technical Specifications Model LC40-1001 LC41-1001 LC42-1001 Price $195.00 $227.00 $274.00 Weight (lb) 1.9 1.9 1.9 Supply Voltage 120VAC @ 50-60 Hz (can be field configured for 240VAC) Consumption 5W maximum Sensor Inputs (1) two wire level switch (2) two wire level switches (3) two wire level switches Sensor Supply 13.5 VDC @ 27mA LED Indication Sensor (green), power (green) & relay (red) Contact Type (1) SPDT relay (non-latching) (1) SPDT relay (latching) (2) SPDT relays, (one non-latching, one latching) Contact Rating 250VAC @ 10A Contact Output Selectable NO / NC Contact Latch N/A Selectable ON / OFF Selectable ON / OFF Contact Delay 0-60 seconds Ambient Temperature -40°F to 158°F [-40°C to 70°C] Enclosure Mounting 35mm DIN rail or thru-hole panel mount Enclosure Material PP (polypropylene), UL94VO Classificaton General purpose Compliance* CE (EN61326, EN61010-1); CSA LR 79326

* To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page at www.AutomationDirect.com

Book 2 (14.3) eLE-30 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Information

Switch-Pro™ Remote Level Drives Controllers Soft Starters Wiring Motors Low Level Alarm Output Wiring Example Automac Fill Output Wiring Example LC40 series: 1 sensor input, 1 relay output. Power (One level sensor input required): (Two level sensor inputs required): Transmission Typical Applicaon:

High level or low Motion: Servos level alarm and Steppers

Motor Controls

Sensors: Proximity LC41 series: 2 sensor inputs, 1 relay output. The relay included is a latching relay. Sensors: Typical Applicaon: Photoelectric Automac fill or High Level Alarm Output Wiring Example Automac Empty Output Wiring Example Sensors: empty (One level sensor input required): (Two level sensor inputs required): Encoders

Sensors: Limit Switches

Sensors: LC42 series: 3 sensor input, 2 relay outputs. One Current relay is latching and the other is a single input relay. Typical Applicaon: Sensors: Pressure Automac fill or empty with high Sensors: level or low level Temperature alarm Level Sensor Input Wiring Example: Sensors: Symbol Key: Level

Dimensions Sensors: Power: Pump: Horn: Valve: inches [mm] Flow Pushbuttons and Lights LZ12 LU10 Stacklights LP15 LV10* Signal * LV10 series can be wired using the White Devices and Black wires for NO operaons or the Red and Black wires for NC operaons. Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves See our website www.AutomationDirect.com for complete Engineering drawings. Pneumatics: Cylinders

Pneumatics: Compatible Products Tubing ProSense Float Level Switches Switch-Tek™ Level Switch Sensors Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/level-switches Level Sensors eLE-31 Prices as of April 27, 2016. Check Web site for most current prices. DataPoint™ Remote Level Controller Overview The LC52 general purpose controller provides single tank level indica- tion with 2 relays, up to three setpoints and an isolated analog repeater. Relay 1 is configurable on a single setpoint. Relay 2 can be configured on a single setpoint or latched on two setpoints for automatic fill or empty control. The controller accepts a 4-20 mA input from any type of level transmitter. The LC52 has a polycarbonate enclosure with integral 35mm DIN rail mounting.

Part No. LC52-1001 Features • 3.5 digit LED display indicates level in custom engineering units • Simple controller for operating 2 alarms or 1 auto fill/empty with • Fail-safe relay control of pumps or valves with 0-60 second delay alarm • Easy set up with pushbutton calibration for span, display and relay • Bar graph provides instant confirmation of transmitter’s operational set points performance • 35mm DIN rail or panel mount polypropylene (PP) enclosure with • Lock-out feature prevents inadvertent setting changes removable terminal strips • Made in the USA • Invert switch changes relay state from NO to NC without rewiring

DataPoint LC52 Series Technical Specifications Model LC52-1001 Price $344.00 Weight (lb) 1.9 Supply Voltage 120VAC @ 50-60 Hz (can be configured for 240VAC) 50-60 Hz Display Type LED, 3.5 digit Display Units Engineering Display Output 0 to 999 LED Indication Power & relay LED Bar Graph Span and setpoints Memory Non-volatile Security Setpoint lock out Configuration Pushbutton Alarm Indication Amber: < 4mA; Red: > 20mA Sensor Input (1) 4-20 mA Sensor Supply 24VDC @ 1.5 W Loop Power 4-20 mA, 18VDC Consumption 5W maximum Contact Type (2) SPDT relays (one non-latching, one latching) Contact Rating 250VAC @ 10A Contact Output Selectable NO / NC Contact Latch ON / OFF Contact Delay 0-60 seconds Repeater Output 4-20 mA, 12-36 VDC, 1200Ω max Ambient Temperature -40°F to 158°F [-40°C to 70°C] Enclosure Mounting 35mm DIN rail or direct panel mount Enclosure Material Polypropylene (PP), UL94VO Classificaton General purpose Compliance* CE (EN50082-2, EN55011, EN61010-1) * To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page at www.AutomationDirect.com

Book 2 (14.3) eLE-32 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company DataPoint™ Remote Level Information Drives

Controller Soft Starters

LC52 series: One 4-20mA sensor input, Motors Wiring 2 relay outputs, 4-20mA repeater output Repeater Ouput (4-20mA) Wiring Example:

RELAY 1RELAY 2 Continuous Controller POWER A Display LATCH EASY CAL LY1 R OFF SET SPA N RLY2 RLY2 B Power 420OP ON OFF INVERT INVERT

DELAY DELAY UP DOWN SET 0% INPUT 100% Transmission Continuous 3.1" Controller + - EASY CAL OFF SE T SPAN RLY 1 RLY2B RLY2A 420OP Motion: Servos UP DOWN SET 0% INPUT 100% + - and Steppers 12-36 VDC POWER Motor Controls Low Level Alarm Output High Level Alarm Output Automac Fill Output Wiring Example: Wiring Example: Wiring Example: Sensors: Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: EchoSonic II (LU23, LU27, LU28 & LU29 Sensors & Limit Switches EchoPod (DL10, DL14, DL24 & DL34) EchoSpan (LU80, LU81, LU83 & LU84 Sensors) Sourcing Mode (Factory Seng) Sourcing Mode (Factory Seng) Sensors: Wiring Example: Wiring Example: Current Symbol Key:

Sensors: Power: Pressure

Sensors: Horn: Sensor Sensor Temperature

Valve: Sensors: Level

Sensors: Flow Dimensions Pushbuttons inches [mm] and Lights

Stacklights

Signal Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: See our website www.AutomationDirect.com for complete Engineering drawings. Directional Control Compatible Products Valves ® ® ® ® ® Pneumatics: EchoSonic II EchoPod EchoSpan EchoTouch ProSense Cylinders Ultrasonic Level Ultrasonic Ultrasonic Level Ultrasonic Level Submersible Level Pneumatics: Transmiters Level Transmitter Transmitters Transmitters Tubing Transmitters Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/level-switches Level Sensors eLE-33 Prices as of April 27, 2016. Check Web site for most current prices. Level Switch Accessories

Level Sensor Accessories

Part No. Item Photo Description Quantity Weight (lb) Price

Flowline Switch-Pak level sensor extension installation fitting, polypropylene (PP) LM45-1001-12 construction, 12 inch insertion length, 2 inch NPT male process connection, 3/4 1 1.1 $46.00 inch NPT female sensor threads, 3/4 inch NPT male electrical junction box threads

Flowline Switch-Pak level sensor extension installation fitting kit, polyvinyl chloride (PVC) construction, includes (1) fitting with 2 inch NPT male process connection, 3/4 inch NPT male electrical junction box threads and 3/4 inch PVC 1 0.7 $30.50 LM45-7001-0000 pipe socket; (1) fitting with 3/4 inch NPT female sensor threads and 3/4 inch female PVC pipe socket. Purchase 3/4 inch schedule 40 PVC pipe separately, cut to desired length and solvent weld to fittings in this kit.

Flowline Switch-Pro compact electrical junction box, polypropylene (PP) con- struction, screw cover with O-ring gasket, NEMA 4X rated, 3/4 inch NPT female 1 0.7 $60.00 LC06-1001 mounting threads with 300 degree swivel base, 1/2 inch NPT female conduit entrance, removable 6-pole terminal strip

Flowline Strobe Alert flashing alarm beacon, 1 per second, polycarbonate (PC) LC09-1004 NEMA 4X housing, amber Xenon tube strobe, powered by 12-36 VDC, 5-inch 1 0.7 $120.00 22AWG lead wires

Cable gland, 1/2 inch NPT male thread, Buna N sealing gland accommodates a LM90-1001 cable diameter range of 0.180 to 0.400 inches (4.6 to 10.2 mm), nylon housing, 1 0.4 $5.50 IP68 protection level

Accessory Field Assembly Examples

Order the following parts for field assembly: (1) LC06-1001 - Junction box Order the following parts for field assembly: (1) LM90-1001 - Cable gland (1) LC06-1001 - Junction box (1) LC09-1004 - Strobe alert flashing alarm Order the following parts for field assembly: (1) LM90-1001 - Cable gland beacon (1) LC06-1001 - Junction box (1) LU10 Series ultrasonic level switch (1) LM90-1001 - Cable gland (1) LC09-1004 - Strobe alert flashing alarm (1) LM45-1001-12 Extension installation fitting kit (1) LV10 Series buoyancy level switch

Book 2 (14.3) eLE-34 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Level Switch Accessory Information Drives

Drawings Soft Starters Dimensions Motors inches [mm] Power Transmission

LM45-1001-12 LM45-7001-0000 Motion: Servos and Steppers

Motor Controls

Sensors: Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons and Lights

Stacklights

Signal Devices

Process

Relays and LC06-1001 Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2 See our website www.AutomationDirect.com for complete Engineering drawings. Terms and Conditions

Book 2 (14.3) www.automationdirect.com/level-switches Level Sensors eLE-35 Prices as of April 27, 2016. Check Web site for most current prices. Level Switch Accessory Drawings Dimensions inches [mm]

LC09-1004 LM90-1001

See our website www.AutomationDirect.com for complete Engineering drawings.

Book 2 (14.3) eLE-36 Level Sensors 1-800-633-0405 Prices as of April 27,2016. Check Web site for most current prices.

Company SLT Series Submersible Level Information Drives

Transmitters Soft Starters Submersible Level Transmitters Motors

The ProSense SLT series submersible level sensors provide continuous liquid level measurement by Power sensing the hydrostatic pressure produced by the height of liquid above the sensor and providing a Transmission 4-20 mA output signal compatible with PLCs, panel meters, data loggers, and other electronic Motion: Servos equipment. The shielded cable with atmospheric vent tube and a tough polyurethane jacket and Steppers incorporating an exclusive “water block” liner beneath the jacket is attached to the sensor using an over-molding process that prevents moisture intrusion. The SLT1 series has a slim 1-inch diameter Motor Controls

housing and a ported bullet nose cap for protection of the sensor diaphragm. The SLT2 series features Sensors: a large 2.75 inch diameter PTFE flexible diaphragm surrounded by a 316 stainless steel non-fouling Proximity protective cage. Accessories include a desiccant vent filter, aneroid bellows, junction boxes, and replace- Sensors: Part No. SLT1-005-L30 ment nose caps. Photoelectric

Sensors: Features Applications Encoders • Models with ported nose cap or non-fouling cage • Lift station monitoring for diaphragm protection Sensors: • Liquid level in vented tank Limit Switches • Durable 316 SS construction for reliable, long life • Landfill leachate monitoring in harsh environments Sensors: • Shielded cable with atmospheric vent; • Construction by-pass pumping Current over-molded to prevent moisture intrusion • Dewatering Sensors: • 1/2 inch NPT male threaded conduit connection • Pump control Pressure on the sensor housing standard • Slurry tank liquid level • Pre-calibrated ranges up to 50 psig (115.3 ftWC) Sensors: to meet the most common submersible level • Wastewater Temperature applications in vented tanks, reservoirs & ground Sensors: water systems Level • +/-0.25% accuracy standard • All sensors include UL and FM hazardous location Sensors: approvals for intrinsically safe applications and are Flow CE marked Pushbuttons • Made in the USA and Lights Part No. SLT2-005-L30 Stacklights

Signal SLT Series Submersible Level Transmitters Devices Model Range Cable Length* Diaphragm / Protection Price Weight (lbs) Process SLT1-005-L30 0–5 psig (11.5 ftWC) 30ft (9.1 m) $299.00 1.9 Relays and Timers SLT1-010-L40 0–10 psig (23.1 ftWC) 40ft (12.2 m) $314.00 2.4 Pneumatics: Air Prep SLT1-015-L60 0–15 psig (34.6 ftWC) 60ft (18.3 m) $344.00 3.4 316 Stainless steel diaphragm / Ported POM (polyoxymethylene) nose cap Pneumatics: Directional Control SLT1-020-L60 0–20 psig (46.1 ftWC) 60ft (18.3 m) $344.00 3.4 Valves

SLT1-030-L100 0–30 psig (69.2 ftWC) 100ft (30.5 m) $402.00 5.4 Pneumatics: Cylinders

SLT1-050-L140 0–50 psig (115.3 ftWC) 140ft (42.7 m) $462.00 7.4 Pneumatics: Tubing

SLT2-005-L30 0–5 psig (11.5 ftWC) 30ft (9.1 m) $470.00 5.0 Pneumatics: Air Fittings SLT2-010-L40 0–10 psig (23.1 ftWC) 40ft (12.2 m) $484.00 5.5 Appendix Book 2 Flexible PTFE (polytetrafluoroethylene) SLT2-015-L60 0–15 psig (34.6 ftWC) 60ft (18.3 m) diaphragm / Non-fouling stainless $514.00 6.5 steel cage Terms and Conditions SLT2-020-L60 0–20 psig (46.1 ftWC) 60ft (18.3 m) $514.00 6.5

SLT2-030-L100 0–30 psig (69.2 ftWC) 100ft (30.5 m) $573.00 8.5

* It is required that any excess cable length be accommodated in a service loop and that the cable NOT be shortened as this will void the warranty. If longer transmitter cable is needed, terminate the sensor in an SLT-JB1 or SLT-JB2 junction box and run standard non-vented instrumentation cable between the junction box and the measuring electronics. Book 2 (14.3) www.automationdirect.com/submersible-level-sensors Level Sensors eLE-37 Prices as of April 27, 2016. Check Web site for most current prices. SLT Series Submersible Level Transmitters

SLT Series Submersible Level Transmittter Technical Specifications Static Accuracy* ±0.25% FS (full scale) Resolution +0.0001% FS SLT1: 316SS; POM (polyoxymethylene), PUR (polyurethane); Wetted Materials SLT2: 316SS; POM (polyoxymethylene), PUR (polyurethane), PTFE (polytetrafluoroethylene)

Compensated Temp. 0 to 50°C [32 to 122°F] Range Thermal Error ±0.1% FS/°C (maximum allowable deviation from the best fit straight line due to a change in temperature)

Operating Temp. Range -20 to 60°C [-4 to 140°F]

Protection Rating IP 68, NEMA 6P Excitation 9–28 VDC Input Current 20mA max Output 4–20 mA Zero Offset w0.25 mA Output Impedance 750ΩΩ max. @ 24VDC (see loop resistance chart by the wiring drawings for other power supply voltages) Mounting Vertical Insulation Resistance 100MΩ at 50VDC Circuit Protection Polarity, surge/shorted output

Cable Jacket Material PUR (polyurethane)

Cable Pull Strength 200lbs (90kg)

Number of Conductors 2 + Drain

Conductor Size 22AWG (0.33 mm²) spiral tinned copper wire foil shield with 20AWG (0.52 mm²) drain wire Vent Tube PUR (polyethylene) 0.016 in (0.41 mm) ID Cable Seal Molded PUR (polyurethane)

Certifications / Agency UL (E197886), CE, RoHS, FM (3036412) Approvals

* Combined effects of non-linearity, hysteresis and repeatability, best fit straight line method. Dimensions inches [mm] SLT1 Series

See our website www.AutomationDirect.com for complete Engineering drawings.

Book 2 (14.3) eLE-38 Level Sensors 1-800-633-0405 Prices as of April 27,2016. Check Web site for most current prices.

Company SLT Series Submersible Level Information Transmitters Drives Soft Starters

Dimensions Motors inches [mm] Power SLT2 Series Transmission Motion: Servos and Steppers

Motor Controls

Sensors: Proximity

Sensors: Photoelectric

Sensors: Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: Pressure See our website www.AutomationDirect.com for complete Engineering drawings. Sensors: Temperature

Sensors: Wiring Level

Sensors: Flow

Pushbuttons and Lights

Stacklights

Signal Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: LOOP RESISTANCE vs. Tubing LOOP POWER SUPPLY 1750 Pneumatics: Air Fittings

(Ω) 1500 L (V+) – 9V Appendix 1250 RL max = 20 mA Book 2 1000 SLT1 & SLT2 Series Wiring Connection Terms and 750 Conditions 4–20 mA output (22AWG conductors in a shielded cable with vent tube) 500 Operating + Excitation Red Loop Resistance, R 250 9V Area 0 - Excitation Black 0 10 20 30 Loop Power Supply Voltage Shield Drain Wire

Book 2 (14.3) www.automationdirect.com/submersible-level-sensors Level Sensors eLE-39 Prices as of April 27, 2016. Check Web site for most current prices. SLT Series Submersible Level Transmitter Accessories Submersible Level Transmitter Vent Filter (Desiccant) Vent filters utilize indicating desiccant to prevent moisture from entering the vent tube and damaging transmitters with vented gage reference pressure. The desiccant will turn from blue to pink when exposed to moisture indicating the need for maintenance. This vent filter design prevents moisture from entering the vent tube for at least one year without maintenance.

Submersible Level Transmitter Vent Filter (Desiccant) Part No. Description Housing Material Tubing Size Connector Material Price Weight (lbs)

ProSense indicating desiccant vent filter, PUR (polyethylene) tube PEEK SLT-VF1 for ProSense submersible hydrostatic level with PP (polypropylene) 13in (330mm) $22.00 0.5 transmitters fittings (Polyetheretherketone) Dimensions inches [mm]

Submersible Level Transmitter Aneroid Bellows The aneroid bellows is a maintenance-free alternative to desiccant filters for moisture protection on vented gage transmitters. Made of flexible neoprene material attached to a polycarbonate mounting bracket, the bellows fluctuates with changes in atmospheric pressure, maintaining a constant barometric reference. Note that the use of the bellows results in a closed reference pressure system subject to zero shift errors induced by changing of up to 0.003 psi/°C.

Submersible Level Transmitter Aneroid Bellows Part No. Description Housing Material Tubing Size Connector Material Price Weight (lbs)

Neoprene bellows attached PEEK SLT-AB1 ProSense aneroid bellows, for ProSense to a PC 12in (305mm) $33.00 0.8 submersible hydrostatic level transmitters (polycarbonate) bracket (Polyetheretherketone) Dimensions inches [mm]

Always install a vent filter (desiccant) or aneroid bellows immediately after transmitter installation. Failure to use one or the other could result in premature failure of the transmitter, which would not be covered by warranty.

See our website www.AutomationDirect.com for complete Engineering drawings. Book 2 (14.3) eLE-40 Level Sensors 1-800-633-0405 Prices as of April 27,2016. Check Web site for most current prices.

Company SLT Series Submersible Level Information Transmitter Accessories Drives Soft Starters Junction Boxes for Submersible Level Motors Transmitters Power Transmission The submersible level transmitter junction boxes provide a water-resistant enclosure for electrically connecting the transmitter cable to the user’s Motion: Servos system via a terminal strip. The enclosure also provides a convenient and Steppers location for terminating the transmitter’s vent tube to a vent filter (included Motor Controls in Part No. SLT-JB1) or an aneroid bellows (included in Part No. SLT-JB2). The enclosure is constructed of polycarbonate with a clear top Sensors: Proximity incorporating a neoprene seal. The junction box is rated IP56. Sensors: Application Photoelectric • If longer transmitter cable is needed, terminate the sensor in an SLT-JB1 or Sensors: SLT-JB2 junction box and run standard instrumentation cable between the Encoders junction box and the measuring electronics. Sensors: Limit Switches

Sensors: Current ProSense Junction Boxes for Submersible Level Transmitters Sensors: Part No. Description Price Weight (lbs) Pressure ProSense junction box for ProSense submersible hydrostatic level transmitter with SLT- $149.00 2.5 SLT-JB1 VF1 indicating desiccant vent filter Sensors: Temperature ProSense junction box for ProSense submersible hydrostatic level transmitters with SLT-JB2 $149.00 2.5 SLT-AB1 aneroid bellows Sensors: Level

Dimensions Sensors: Flow inches [mm] Pushbuttons Part No. SLT-JB1 and Lights

Stacklights

Signal Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

See our website www.AutomationDirect.com for complete Engineering drawings.

Book 2 (14.3) www.automationdirect.com/submersible-level-sensors Level Sensors eLE-41 Prices as of April 27, 2016. Check Web site for most current prices. SLT Series Submersible Level Transmitter Accessories

Dimensions inches [mm] Part No. SLT-JB2

See our website www.AutomationDirect.com for complete Engineering drawings.

Book 2 (14.3) eLE-42 Level Sensors 1-800-633-0405 Prices as of April 27,2016. Check Web site for most current prices.

Company SLT Series Submersible Level Information Transmitters Accessories Drives Soft Starters

Motors Submersible Level Transmitter Replacement Open-face Power Nose Cap Transmission

The open-face nose cap offers the best resistance to clogging. This single-piece nose cap provides Motion: Servos maximum exposure of the sensing diaphragm to the liquid media through a protective perforated and Steppers screen on the front. The open-face nose cap is constructed from molded polyoxymethylene (POM). Motor Controls

Sensors: Proximity

Submersible Level Transmitter Replacement Open-Face Nose Cap Sensors: Photoelectric Part No. Description Price Weight (lbs) Sensors: ProSense open-faced nose cap, interchangeable with ported bullet nose cap on any ProSense SLT1 Encoders SLT-CAP1 series hydrostatic level transmitter, polyoxymethylene (POM) $25.00 0.1

Sensors: Dimensions Limit Switches Sensors: inches [mm] Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons Submersible Level Transmitter Replacement Ported Bullet and Lights Nose Cap Stacklights The ported bullet nose cap offers the best protection against damage to the sensing diaphragm. This Signal single-piece nose cap allows the liquid media to enter through six 1/8” holes around the outside Devices and includes a #8-32 UNC-2B threaded hole on the front. The closed-face nose cap is constructed Process of molded polyoxymethylene (POM). Relays and Timers

Submersible Level Transmitter Replacement Ported Bullet Nose Cap Pneumatics: Air Prep Part No. Description Price Weight (lbs) Pneumatics: SLT-CAP2 ProSense ported bullet nose cap, replacement, for ProSense SLT1 series submersible hydrostatic level $25.00 0.1 Directional Control transmitters, polyoxymethylene (POM) Valves

Pneumatics: Dimensions Cylinders inches [mm] Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

See our website www.AutomationDirect.com for complete Engineering drawings.

Book 2 (14.3) www.automationdirect.com/submersible-level-sensors Level Sensors eLE-43 Prices as of April 27, 2016. Check Web site for most current prices. Float Level Switches

• Stem materials: Polypropylene (PP), Float Level Switches, Polybutylene Terephthalate (PBT), Brass, 316SS, Kynar (PVDF), PTFE “Teflon” Vertical Top-Mount • Mounting: 3/8-16 UNC, 1/8” MNPT, 1/4” Float materials: Polypropylene (PP), MNPT (install +/- 30° from vertical) Buna-N, 316SS, Kynar (PVDF), - Can also be mounted with the mounting PTFE “Teflon” threads below the float (bottom mount) as in the bottom of a tank  • Temperature range: -40°F up to 392°F (depending on model) • Max pressure ratings: up to 500 psig (FLS VL-600) • Made in the USA See pg.LE-46

Float Level Switches, • Stem material: Brass • Slosh shield: Polybutylene Terephthalate (PBT) Vertical Suspendible / • Mounting: Suspendible cable Submersible • Temperature range: -40°F to 221°F Float material: Buna-N • Max pressure: 50 psig • Made in the USA • The FLS-VL-900 suspendible / submersible float See pg. LE-55

• Stem materials: Polypropylene (PP), Polybutylene Float Level Switches, Terephthalate (PBT), 316SS, Kynar (PVDF), Brass Horizontal Side-Mount • Mounting: 3/8-24 UNC, 5/8-11 UNC, 1/2-13 UNC, Float materials: Polypropylene (PP), 1/2” MNPT, dual 1/2” MNPT, 1” MNPT x 1/2” MNPT Polybutylene Terephthalate (PBT), • Temperature ranges: -40°F up to 392°F (depending on model) 316SS, Kynar (PVDF), Buna-N • Max : up to 300 psig • Made in the USA

See pg.LE-56

Float Level Switch Kits Each kit contains: • 2-inch NPT male threaded pipe plug ProSense float level switch kits provide with attached cuttable mounting tube the opportunity to fabricate in the field a • Two additional cuttable connecting tubes customized two-float level switch using • Two floats the supplied kit components. Level • Two SPST switch capsules that can switch kits are available in three different function as either normally closed or material constructions (polypropylene, normally open depending on float orientation brass, stainless steel) for compatibility • Four compression unions with different liquids • One compression end cap • Made in the USA See pg.LE-62

Float Level Tilt Switches Float level tilt switches provide inexpensive, three-conductor cable and operates efficient and highly reliable level detec- on a mercury-free micro-switch device tion in open vessels, sumps and ponds. that is located inside the float on an The molded rubber float has an integral anti-vibration mount.

See pg.LE-66

Book 2 (14.3) eLE-44 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches ProSense Float Level Switches Information ProSense float level switches provide a low-cost general purpose solution for Drives single point monitoring of liquid level in a variety of applications. Powerful permanent magnets within the float actuate a highly reliable and repeat- Soft Starters able hermetically sealed reed switch as the float rises and lowers with liquid level. These switches are available in several different material construc- Motors tions for compatibility with many types of liquids, a wide temperature range, Power and system pressure requirements. Vertical and horizontal mounting styles Transmission with several mounting thread variations are offered for ease of installation. Motion: Servos Reed switches carry electrical ratings for both AC and DC voltage for adapt- and Steppers ability to many control interface applications. Although these switches come configured for normally closed operation, most models can be easily Motor Controls converted to normally open operation in the field. Designed to be shock and Sensors: vibration resistant, ProSense float level switches ensure long and trouble-free Proximity service. Sensors: Photoelectric Features Sensors: • Low-cost solution for general purpose single point liquid level monitoring Encoders • Magnetically operated, highly reliable and repeatable hermetically sealed reed switch Sensors: Limit Switches • Vertical and horizontal mounting styles with a variety of mounting threads • Several material constructions for compatibility with different liquids Sensors: Current • Electrical ratings for AC and DC voltage • Most switches easily converted in the field from normally closed to normally open Sensors: operation Pressure

• Made in the USA Sensors: Temperature

Sensors: Operation Level

ProSense float level switches are shipped configured for Vertical Mount switches can also be mounted with the mounting Sensors: Flow normally closed switch operation. Except where noted, most threads below the float (bottom mount) as in the bottom of a models can be easily converted to normally open operation in tank. If bottom mounted, switch operation will be the opposite Pushbuttons the field. of top mounted installation described above. and Lights

Vertical Mount Switches Horizontal Mount Switches Stacklights For Vertical Mount switches, normally closed is defined as the For Horizontal Mount switches installed in the side of a tank Signal switch mounted in a vertical position with the mounting threads (side-mounted), normally closed is defined as when the float Devices above the float (top mount) and the float in the “dry” position arm is below and parallel with the stem in the “dry” position at the bottom of the stem (Figure 1). When the liquid raises the (Figure 2). When the liquid raises the float, the switch will open. Process float, the switch will open. To change the operation of the switch, rotate the installed Relays and To change the operation of the switch to normally open, remove position of the switch 180 degrees so the float arm is above Timers the C-clip, remove the float from the stem, flip the float 180 and hanging at an angle with the stem. Now the switch will Pneumatics: degrees, re-install the float on the stem and replace the C-clip. be normally open in the “dry” position and will close when the Air Prep Now the switch will be normally open in the “dry” position and liquid raises the float. Pneumatics: will close when the liquid raises the float. Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Normally Closed Installation (Dry) Tubing Normally Closed Installation (Dry) Pneumatics: Air Fittings To Change Operation To Normally Open Appendix Book 2 Step 1: Remove C-Clip Normally Open Installation (Dry) Step 2: Flip Float On Stem 180° Terms and Step 3: Reinstall C-Clip Conditions

Figure 1: Vertical (Top) Mount Switch Operation Figure 2: Horizontal Mount Switch Operation

Book 2 (14.3) www.automationdirect.com/ultrasonic-level-sensors Level Sensors eLE-45 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Vertical Top-Mount

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Hole (lbs) SPST-NC, 15W max Ø 0.375 in Polypropylene Polypropylene -40°F to 221°F 50 psig 22AWG, [9.53 mm] cURus, CE $20.25 0.7 120VAC, 0.12 A 0.02 FLS-VS-100 (PP) (PP) [-40°C to 105°C] [3.4 bar] 100VDC, 0.1 A Teflon 24in (Install w 30° (See Approvals 24VDC, 0.3 A max from table for details) 12VDC, 0.3 A vertical) * Normally closed switch only. Cannot be converted to function as normally open. Electrical ratings are for resistive loads ONLY. For inductive loads, maxi- mum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 15W max 1/8 in MNPT Polypropylene Polypropylene -40°F to 221°F 50 psig 22AWG, CE $20.25 0.7 120VAC, 0.12 A (Install w 30° 0.02 FLS-VS-200 (PP) (PP) [-40°C to 105°C] [3.4 bar] 100VDC, 0.1 A Teflon 24in max from (See approvals 24VDC, 0.3 A vertical) table for details) 12VDC, 0.3 A * Normally closed switch only. Cannot be converted to function as normally open. Electrical ratings are for resistive loads ONLY. For inductive loads, maxi- mum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-46 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Vertical Information Top-Mount Drives Soft Starters

Float Level Switch Specifications Motors Float Float Stem Temperature Electrical Lead Mounting Weight Power Part No. Price Pressure Specific Approvals Transmission Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, Motion: Servos 30W max 1/8 in MNPT cURus, CSA, and Steppers Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, FLS-VM-100 $10.50 0.8 240VAC, 0.14 A (Install w 30° CE 0.1 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A MTW 24in max from (See Approvals Motor Controls 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A Sensors: * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads Proximity ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders

inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons Float Level Switch Specifications and Lights

Float Stacklights Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range* Rating1 Wires Thread (lbs) Gravity Signal Devices SPST-NC, cURus, CSA, Polybutylene 30W max 1/8 in MNPT Terephthalate -40°F to 221°F 150 psig 240VAC, 0.14 A 22AWG, (Install w 30° CE Process FLS-VM-200 $12.00 Buna-N 0.45 120VAC, 0.28 A 0.1 (PBT) [-40°C to 105°C] [10.4 bar] Teflon 24in max from (See Approvals 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A Relays and Timers * Not for use in hot water at temperatures above 149ºF [65ºC]

1 Pneumatics: Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads Air Prep ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS.

Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Pneumatics: Directional Control Dimensions Valves Pneumatics: inches [mm] Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-47 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Vertical Top-Mount

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 30W max 1/8 in MNPT -40°F to 221°F 150 psig 22AWG, cURus, CSA, CE $23.50 Buna-N Brass 0.45 240VAC, 0.14 A (Install w 30° 0.1 FLS-VM-300 [-40°C to 105°C] [10.3 bar] 120VAC, 0.28 A Teflon 24in max from (See Approvals 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 30W max 1/8 in MNPT cURus, CSA, -40°F to 392°F 300 psig 22AWG, FLS-VM-400 $38.00 316SS 316SS 0.7 240VAC, 0.14 A (Install w 30° CE 0.1 [-40°C to 200°C] [20.7 bar] 120VAC, 0.28 A Teflon 24in max from (See Approvals 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-48 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Vertical Information Top-Mount Drives Soft Starters

Float Level Switch Specifications Motors Float Float Stem Temperature Electrical Lead Mounting Weight Power Part No. Price Pressure Specific Approvals Transmission Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, Motion: Servos 60W max 1/8 in MNPT cURus, CE and Steppers Kynar Kynar -40°F to 221°F 15 psig 240VAC, 0.4 A 22AWG, FLS-VM-500 $29.50 0.85 (Install w 30° (See Approvals 0.1 (PVDF) (PVDF) [-40°C to 105°C] [1bar] 120VAC, 0.5 A Teflon 24in max from Motor Controls 120VDC, 0.2 A vertical) table for details) 24VDC, 0.5 A Sensors: * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads Proximity ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons Float Level Switch Specifications and Lights Float Stacklights Part No. Price Float Material Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Range Rating* Wires Thread (lbs) Signal Gravity Devices SPST-NC, 25 psig Polytetrafluoroethylene 60W max 1/8 in MNPT Process PTFE -40°F to 302°F [1.7 bar] 22AWG, CE $173.00 (PTFE) 0.69 240VAC, 0.4 A (Install w 30° 0.1 FLS-VM-600 “Teflon” [-40°C to 150°C] @ 21°C 120VAC, 0.5 A Teflon 24in max from (See Approvals “Teflon” table for details) Relays and [69.8°F] 120VDC, 0.2 A vertical) Timers 24VDC, 0.5 A * Normally closed switch. Cannot be converted to function as normally open. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life Pneumatics: will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Air Prep Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Pneumatics: Directional Control Dimensions Valves Pneumatics: inches [mm] Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-49 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Vertical Top-Mount

Float Level Switch Specifications Stem / Float Part No. Price Float Slosh Shield Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 30W max 1/8 in MNPT Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, cURus, CSA, CE $20.75 0.8 240VAC, 0.14 A (Install w 30° 0.1 FLS-VL-010 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A MTW 24in max from (See Approvals 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Stem / Temperature Float Electrical Lead Mounting Weight Part No. Price Slosh Shield Pressure Specific 1 Approvals Material Material Range* Gravity Rating Wires Thread (lbs) SPST-NC, cURus, CSA, Polybutylene 30W max 1/8 in MNPT Terephthalate -40°F to 221°F 150 psig 240VAC, 0.14 A 22AWG, (Install w 30° CE FLS-VL-020 $25.25 Buna-N 0.45 120VAC, 0.28 A 0.1 (PBT) [-40°C to 105°C] [10.3 bar] Teflon 24in max from (See Approvals 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A * Not for use in hot water at temperatures above 149ºF [65ºC] 1 Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-50 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Vertical Information Top-Mount Drives Soft Starters

Float Level Switch Specifications Motors Stem / Float Part No. Price Float Slosh Shield Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Power Material Material Range Gravity Rating* Wires Thread (lbs) Transmission SPST-NC, Motion: Servos 30W max 1/8 in MNPT cURus, CSA, and Steppers -40°F to 392°F 300 psig 240VAC, 0.14 A 22AWG, (Install w 30° CE FLS-VL-030 $53.00 316SS 316SS 0.7 120VAC, 0.28 A 0.2 [-40°C to 200°C] [20.7 bar] Teflon 24in max from (See Approvals Motor Controls 120VDC, 0.07 A vertical) table for details) 24VDC, 0.28 A Sensors: * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads Proximity ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons Float Level Switch Specifications and Lights Stem / Float Float Temperature Electrical Lead Mounting Weight Stacklights Part No. Price Material Slosh Shield Range Pressure Specific Rating* Wires Thread Approvals (lbs) Material Gravity Signal SPST-NC, Devices 60W max 1/4 in MNPT -40°F to 392°F 200 psig 22AWG, CSA, CE, $93.00 316SS 316SS 0.55 240VAC, 0.4 A (Install w 30° 0.4 Process FLS-VL-040 [-40°C to 200°C] [13.8 bar] 120VAC, 0.5 A Teflon 24in max from (See Approvals 120VDC, 0.2 A vertical) table for details) 24VDC, 0.5 A Relays and Timers * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Pneumatics: Air Prep Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device.

Pneumatics: Directional Control Dimensions Valves

inches [mm] Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-51 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Vertical Top-Mount Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 60W max 1/4 in MNPT Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, cURus, CSA, CE $43.25 0.75 240VAC, 0.4 A (Install w 30° 0.1 FLS-VL-100 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.5 A MTW 24in max from (See Approvals 120VDC, 0.2 A vertical) table for details) 24VDC, 0.5 A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications

Float Stem Temperature Float Electrical Lead Mounting Weight Part No. Price Pressure Specific 1 Approvals Material Material Range* Gravity Rating Wires Thread (lbs) SPST-NC, 60W max 1/4 in MNPT Polybutylene -40°F to 221°F 150 psig 22AWG, cURus, CSA, CE $25.00 Buna-N Terephthalate 0.45 240VAC, 0.4 A (Install w 30° 0.1 FLS-VL-200 [-40°C to 105°C] [10.3 bar] 120VAC, 0.5 A Teflon 24in max from (See Approvals (PBT) 120VDC, 0.2 A vertical) table for details) 24VDC, 0.5 A * Not for use in hot water at temperatures above 149ºF [65ºC] 1 Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-52 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Vertical Information Top-Mount Drives Soft Starters

Float Level Switch Specifications Motors Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Power Material Material Range Gravity Rating* Wires Thread (lbs) Transmission

SPST-NC, Motion: Servos 60W max 1/4 in MNPT and Steppers -40°F to 221°F 150 psig 22AWG, cURus, CSA, CE $25.00 Buna-N Brass 0.45 240VAC, 0.4 A (Install w 30° 0.3 FLS-VL-300 [-40°C to 105°C] [10.3 bar] 120VAC, 0.5 A MTW 24in max from (See Approvals 120VDC, 0.2 A vertical) table for details) Motor Controls 24VDC, 0.5 A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads Sensors: Proximity ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS.

Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Float Level Switch Specifications Pushbuttons and Lights Float Stem Minimum** Maximum Float Electrical Lead Mounting Weight Part No. Price Pressure Specific Approvals Stacklights Material Material Temperature Temperature Gravity Rating* Wires Thread (lbs) Signal UR, CSA, CE, 240VAC, 0.4 A 1/4 in MNPT Devices -40°F 392°F 200 psig 120VAC, 0.5 A 22AWG, (See Approvals $53.00 316SS 316SS 0.55 (Install w 30° table for details) 0.3 FLS-VL-400 [-40°C] [200°C] [13.8 bar] 120VDC, 0.2 A Teflon 24in max from Process 24VDC, 0.5 A vertical) Haz-Loc Approvals Relays and * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads Timers ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Pneumatics: ** -40°F [-40°C] rating not UL tested Air Prep Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Pneumatics: Directional Control Dimensions Valves

Pneumatics: inches [mm] Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-53 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Vertical Top-Mount

Float Level Switch Specifications Float Part No. Price Float Material Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 40 psig Polytetrafluoroethylene 60W max 1/4 in MNPT CE (PTFE) PTFE -40°F to 302°F [2.8 bar] 240VAC, 0.4 A 22AWG, (Install w 30° FLS-VL-500 $257.00 0.63 120VAC, 0.5 A (See Approvals 0.1 “Teflon” “Teflon” [-40°C to 150°C] @ 21°C Teflon 24in max from table for details) [69.8°F] 120VDC, 0.2 A vertical) 24VDC, 0.5 A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 100W max 1/4 in MNPT -40°F to 392°F 500 psig 22AWG, CE $67.25 316SS 316SS 0.7 240VAC, 0.4 A (Install w 30° 0.3 FLS-VL-600 [-40°C to 200°C] [34.5 bar] 120VAC, 1A Teflon 24in max from (See Approvals 120VDC, 0.4 A vertical) table for details) 24VDC, 1A * Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-54 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Vertical Information Suspendible / Submersible Drives Soft Starters

Float Level Switch Specifications Motors Float Float Stem Slosh Temperature Electrical Lead Weight Power Part No. Price Pressure Specific 1 Mounting Approvals Transmission Material Material Shield Range* Gravity Rating Wires (lbs) SPST-NC, Motion: Servos and Steppers Polybutylene 30W max 22AWG, CE -40°F to 221°F 50 psig 240VAC, 0.14 A Suspendible FLS-VL-900 $98.75 Buna-N Brass Terephthalate 0.45 Halar jacketed (See Approvals 0.3 [-40°C to 105°C] [3.4 bar] 120VAC, 0.28 A cable Motor Controls (PBT) 120VDC, 0.07 A 20-foot cable table for details) 24VDC, 0.28 A Sensors: * Not for use in hot water at temperatures above 149ºF [65ºC] Proximity 1 Normally closed switch. Can be converted in the field to function as normally open as described under “Operation”. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Sensors: Photoelectric Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Dimensions Encoders Sensors: inches [mm] Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons and Lights

Stacklights

Signal Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-55 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Horizontal Side-Mount

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 30W max cURus, CSA, Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, Dual FLS-HS-100 $12.00 0.6 240VAC, 0.14 A CE 0.1 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A MTW 24in 1/2 in MNPT (See Approvals 120VDC, 0.07 A table for details) 24VDC, 0.28 A * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Hole (lbs) SPST-NC, 30W max cURus, CSA, Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, FLS-HS-200 $14.25 0.6 240VAC, 0.14 A Ø 0.625 in CE 0.1 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A MTW 24in [16 mm] (See Approvals 120VDC, 0.07 A table for details) 24VDC, 0.28 A * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-56 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Horizontal Information Side-Mount Drives Soft Starters

Float Level Switch Specifications Motors Float Float Stem Temperature Electrical Lead Mounting Weight Power Part No. Price Pressure Specific Approvals Transmission Material Material Range Gravity Rating* Wires Hole (lbs) SPST-NC, Motion: Servos 30W max and Steppers Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, CE $25.75 0.6 240VAC, 0.14 A Ø 0.91 in 0.1 FLS-HS-300 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A MTW 24in [23.1 mm] (See Approvals 120VDC, 0.07 A table for details) Motor Controls 24VDC, 0.28 A Sensors: * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum Proximity life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders

inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level TANK WALL

COMPRESSION Sensors: COMPRESSED GASKET FLANGE Flow GASKET TO INSTALL: INSERT SWITCH Pushbuttons FROM OUTSIDE and Lights Ø0.91 [Ø23.1] OF TANK & TIGHTEN MOUNTING HOLE COMPRESSION NUT Stacklights

Signal Float Level Switch Specifications Devices Float Float Stem Temperature Electrical Lead Mounting Weight Process Part No. Price Pressure Specific 1 2 Approvals Material Material Range* Gravity Rating Wires Thread (lbs) Relays and SPST-NC, Timers 30W max Polybutylene Polybutylene -40°F to 266°F 100 psig 240VAC, 0.14 A 22AWG, Dual cURus, CSA, CE FLS-HM-100 $18.00 Terephthalate Terephthalate 0.7 (See Approvals 0.1 Pneumatics: (PBT) (PBT) [-40°C to 130°C] [6.9 bar] 120VAC, 0.28 A Teflon 24in 1/2 in MNPT table for details) Air Prep 120VDC, 0.07 A 24VDC, 0.28 A Pneumatics: * Not for use in hot water at temperatures above 149ºF [65ºC] Directional Control Valves 1 Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Pneumatics: Cylinders 2 Leadwires rated for 140ºF [60ºC] max when exposed to oil

Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Pneumatics: Tubing

Dimensions Pneumatics: Air Fittings inches [mm] Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-57 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Horizontal Side-Mount

Float Level Switch Specifications Float Part No. Price Float Stem Minimum** Maximum Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Temperature Temperature Gravity Rating* Wires Thread (lbs) UR, CSA, 240VAC, 0.14 A CE -40°F 392°F 300 psig 22AWG, Dual FLS-HM-200 $130.00 316SS 316SS 0.6 120VAC, 0.28 A (See Approvals 0.3 [-40°C] [200°C] [20.7 bar] 120VDC, 0.07 A Teflon 24in 1/2 in MNPT table for details) 24VDC, 0.28 A Haz-Loc Approvals * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. ** -40°F [-40°C] rating not UL tested Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, 30W max Kynar Kynar -40°F to 221°F 100 psig 22AWG, Dual cURus, CE, $24.50 0.93 240VAC, 0.14 A 0.2 FLS-HM-300 (PVDF) (PVDF) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A Teflon 24in 1/2 in MNPT (See Approvals 120VDC, 0.07 A table for details) 24VDC, 0.28 A * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-58 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Horizontal Information Side-Mount Drives Soft Starters

Float Level Switch Specificationsld Motors Float Float Stem / Slosh Temperature Electrical Lead Mounting Weight Power Part No. Price Pressure Specific Approvals Transmission Material Shield Material Range Gravity Rating* Wires Thread (lbs) SPST-NC, Motion: Servos 30W max CE and Steppers Polypropylene Polypropylene -40°F to 221°F 100 psig 240VAC, 0.14 A 22AWG, 1in MNPT x FLS-HL-010 $25.25 0.6 (See Approvals 0.2 (PP) (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A MTW 24in 1/2 in MNPT Motor Controls 120VDC, 0.07 A table for details) 24VDC, 0.28 A Sensors: * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum Proximity life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders

inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons and Lights Float Level Switch Specifications Stacklights Float Stem Temperature Float Electrical Lead Mounting Weight Part No. Price Material Material Range Pressure Specific Rating* Wires Hole Approvals (lbs) Signal Gravity Devices SPST-NC, 30W max cURus, CE Process -40°F to 392°F 100 psig 240VAC, 0.14 A 22AWG, Ø 0.563 in FLS-HL-200 $72.50 316SS 316SS 0.7 120VAC, 0.28 A [14.3 mm] (See Approvals 0.3 [-40°C to 200°C] [6.9 bar] Teflon 24in table for details) Relays and 120VDC, 0.07 A Timers 24VDC, 0.28 A

* Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum Pneumatics: life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Air Prep Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Pneumatics: Directional Control Dimensions Valves Pneumatics: inches [mm] Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-59 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches, Horizontal Side-Mount

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Hole (lbs) SPST-NC, 30W max Polypropylene -40°F to 221°F 100 psig 22AWG, CE $44.25 316SS 0.8 240VAC, 0.14 A Ø 0.406 in 0.2 FLS-BM-100 (PP) [-40°C to 105°C] [6.9 bar] 120VAC, 0.28 A Teflon 24in [10.3 mm] (See Approvals 120VDC, 0.07 A table for details) 24VDC, 0.28 A * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Float Level Switch Specifications Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Hole (lbs) SPST-NC, 30W max -40°F to 221°F 150 psig 22AWG, CE $38.00 Buna-N Brass 0.45 240VAC, 0.14 A Ø 0.406 in 0.2 FLS-BM-200 [-40°C to 105°C] [10.3 bar] 120VAC, 0.28 A Teflon 24in [10.3 mm] (See Approvals 120VDC, 0.07 A table for details) 24VDC, 0.28 A * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device.

Dimensions inches [mm]

Book 2 (14.3) eLE-60 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switches, Horizontal Information Side-Mount Drives Soft Starters

Float Level Switch Specifications Motors Float Float Stem Temperature Electrical Lead Mounting Weight Power Part No. Price Pressure Specific Approvals Transmission Material Material Range Gravity Rating* Wires Hole (lbs) SPST-NC, Motion: Servos 30W max and Steppers -40°F to 392°F 300 psig 22AWG, CSA, cURus, CE $41.50 316SS 316SS 0.7 240VAC, 0.14 A Ø 0.406 in 0.2 FLS-BM-300 [-40°C to 200°C] [20.7 bar] 120VAC, 0.28 A Teflon 24in [10.3 mm] (See Approvals 120VDC, 0.07 A table for details) Motor Controls 24VDC, 0.28 A Sensors: * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum Proximity life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons Float Level Switch Specifications and Lights Float Part No. Price Float Stem Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Stacklights Material Material Range Gravity Rating* Wires Thread (lbs) Signal SPST-NC, Devices 30W max -40°F to 392°F 50 psig 22AWG, CE $91.75 316SS 316SS 0.6 240VAC, 0.14 A 1/2 in MNPT 0.3 FLS-BL-100 [-40°C to 200°C] (3.4 bar) 120VAC, 0.28 A Teflon 24in (See Approvals Process 120VDC, 0.07 A table for details) 24VDC, 0.28 A Relays and * Can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum Timers life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Pneumatics: Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Air Prep

Pneumatics: Dimensions Directional Control Valves inches [mm] Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-61 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switch Kits

Float Level Switch Kits ProSense float level switch kits provide the opportunity to fabricate in the field a customized two-float level switch with a maximum stem length of 36 inches (914.4 mm) using the supplied kit components. Level switch kits are available in three different material constructions for compatibility with different liquids. Each kit is furnished with the following components: • 2-inch NPT male threaded pipe plug with attached cuttable mounting tube • Two additional cuttable connecting tubes • Two floats • Two SPST switch capsules that can function as either normally closed or normally Plastic open depending on float orientation • Four compression unions • One compression end cap

Assembly of ProSense float level switch kits generally involves the following steps: • Lay out the supplied components in the required configuration • Determine the lengths of the connecting tubes and cut them accordingly • De-burr and smooth the sharp edges of the cut tubes prior to installation • Perform a trial assembly and using a continuity indicator (light, buzzer, Ohm meter, etc.), verify that the switch actuation levels are at the required levels and the switch action (normally open or normally closed) is correct for the application. • When switch set-up is satisfactory, tighten the fittings and apply thread sealant to the pipe threads on the top fitting before installing the switch into the tank. Brass Installation Example

RED WIRES FROM BLACK WIRES L1 SWITCH

FROM L2 SWITCH PIPE FITTING TUBE- 2" NPT MALE CUT TO L1 - 2.46"

UNION - TYP .90" ( L1 ) TUBE END WITNESS MARK- INSERTION FLOAT IN NORMALLY L1 DEPTH OPEN POSITION

2.46" Stainless Steel ACTUATION ACTUATION POINT POINT

2.46" L2 L1 SWITCH SWITCH CAPSULE CAPSULE DO NOT CUT RED WIRES TIGHTEN NUT WHILE HOLDING TUBE END FITTING BODY HOLD CONNECTING TUBE WHEN TIGHTENING UNION-TYPICAL

BLACK WIRES FROM L2 SWITCH L2 SWITCH CAPSULE BLACK WIRES

ACTUATION WITNESS MARK- POINT FLOAT IN NORMALLY CLOSED POSITION

END CAP Book 2 (14.3) eLE-62 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switch Kits Information

Drives

Soft Starters

Float Level Switch Specifications Motors Other Float Float Temperature Electrical Lead Mounting Weight Power Part No. Price Components Pressure Specific Approvals Transmission Material Material Range Gravity Rating* Wires Thread (lbs) SPST NO or NC, Motion: Servos 60W max 2in MNPT and Steppers Polypropylene Polypropylene -40°F to 221°F 100 psig 22AWG, cURus, CE $314.00 0.75 240VAC, 0.4 A pipe plug / 1.0 FLS-VK-100 (PP) (PP) [-40°C to 105°C] [6.89 bar] 120VAC, 0.5 A Teflon 6ft 1/2 in MNPT (See Approvals 120VDC, 0.2 A conduit table for details) Motor Controls 24VDC, 0.5 A Sensors: * Each float can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive Proximity loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons and Lights

Stacklights

Signal Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-63 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switch Kits

Float Level Switch Specifications Other Float Part No. Price Float Components Temperature Pressure Specific Electrical Lead Mounting Approvals Weight Material Material Range Gravity Rating* Wires Thread (lbs) SPST NO or NC, 60W max 2in MNPT pipe -40°F to 221°F 150 psig 22AWG, plug / cURus, CE $177.00 Buna-N Brass 0.45 240VAC, 0.4 A 4.0 FLS-VK-200 [-40°C to 105°C] [10.34 bar] 120VAC, 0.5 A Teflon 6ft 1/2 in MNPT (See Approvals 120VDC, 0.2 A conduit table for details) 24VDC, 0.5 A * Each float can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Dimensions inches [mm]

Book 2 (14.3) eLE-64 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Switch Kits Information

Drives

Soft Starters

Float Level Switch Specifications Motors Other Float Float Temperature Electrical Lead Mounting Weight Power Part No. Price Components Pressure Specific Approvals Transmission Material Material Range Gravity Rating* Wires Thread (lbs) SPST NO or NC, Motion: Servos 2in MNPT 60W max cURus, CE and Steppers -40°F to 392°F 200 psig 240VAC, 0.4 A 22AWG, pipe plug / FLS-VK-300 $358.00 316SS 316SS 0.55 120VAC, 0.5 A 1/2 in MNPT (See Approvals 4.0 [-40°C to 200°C] [13.79 bar] Teflon 6ft table for details) Motor Controls 120VDC, 0.2 A conduit 24VDC, 0.5 A Sensors: * Each float can be installed to function as either normally open or normally closed switch. Electrical ratings are for resistive loads ONLY. For inductive Proximity loads, maximum life will be obtained with the use of appropriate transient suppression such as an MOV or TVS. Caution: Not recommended for use with PLC AC inputs or other digital AC input devices due to damage that may occur to the switch or input device. Sensors: Photoelectric

Dimensions Sensors: Encoders

inches [mm] Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Temperature

Sensors: Level

Sensors: Flow

Pushbuttons and Lights

Stacklights

Signal Devices

Process

Relays and Timers

Pneumatics: Air Prep

Pneumatics: Directional Control Valves

Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Book 2

Terms and Conditions

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-65 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Tilt Switches

Float Level Tilt Switches Float level tilt switches provide inexpensive, efficient and highly reliable level detection in open vessels, sumps and ponds. The molded rubber float has an integral three-conductor cable and operates on a mercury-free micro-switch device that is located inside the float on an antivibration mount. The rubber float is constructed of ethylene propylene diene (EPDM), a synthetic rubber with rigid and durable characteristics for long service life and resistance to heat, oxidation, ozone and aging due to weather. EPDM has good electrical resistivity, as well as resistance to solvents such as water, acids, alkalies, phosphate esters and many ketones and alcohols. The basic operating principle is that as the fluid level rises, the float will rise, causing the microswitch to tilt and generate a signal that can be used to start or stop a pump, open or close a valve or actuate indicator alarms as required. Float travel is in an approximately ± 45˚ arc from its nominal position. Features • Low cost • Easy installation • Versatile application • Mercury-free SPDT 16 amp switch • 7 meter (22.9 foot) PVC jacketed cable

Installation Example

Float Travel is proportional to distance between oat body and weight or anchor point.

Example 1: 6 inches between oat body and weight will require 12 inches total oat travel for proper opertaion of switch.

Example 2: 18 inches between oat body and weight will require 36 inches total oat travel to proper operation of switch.

Switch point is approximately ± 45 deg from horizontal at tethered or weighted point on cable.

Book 2 (14.3) eLE-66 Level Sensors 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices.

Company Float Level Tilt Switches Information

Drives

Soft Starters

Float Level Tilt Switch Specifications Motors

Sealed Float Power Part No. Price Float Weight Float Shape Temperature Pressure Specific Electrical Cable Approvals Weight Transmission Material Housing Range Gravity Ratings* Material Motion: Servos and Steppers 14.5 psig SPDT 3-conductor [1bar] 16A Motor Controls Polypropylene 32°F to 158°F 18AWG PVC $32.25 EPDM Rubber Rectangle Max 0.9 to 1.3 250VAC, 60Hz CE 3.5 FLS-HT-100 (PP) [0°C to 70°C] submerged jacket 22.9 ft Sensors: depth 65 feet 1/2 HP, 250VAC, 60Hz [7 meter] [20 meters] 10A, 24VDC Proximity

Sensors: Dimensions Photoelectric Sensors: inches [mm] Encoders

Sensors: Limit Switches

Sensors: Current

Sensors: Pressure

Sensors: Wiring Temperature Brown

Sensors: Black Level Blue Sensors: Flow

Pushbuttons and Lights

Float Level Tilt Switch Specifications Stacklights Sealed Float Signal Part No. Price Float Weight Float Shape Temperature Pressure Specific Electrical Cable Approvals Weight Devices Material Housing Range Gravity Ratings* Material Process SPDT 14.5 psig 3-conductor Relays and 16A Polypropylene 32°F to 158°F [1bar] Max 18AWG PVC Timers $32.25 EPDM Rubber Oval 0.7 to 1.3 CE 3.5 FLS-HT-200 (PP) (0°C to 70°C) submerged 250VAC, 60Hz jacket 22.9 ft depth 65 feet 1/2 HP, 250VAC, 60Hz [7 meter] Pneumatics: [20 meters] 10A, 24VDC Air Prep

Pneumatics: Dimensions Directional Control Valves inches [mm] Pneumatics: Cylinders

Pneumatics: Tubing

Pneumatics: Air Fittings

Appendix Wiring Book 2 Brown Terms and Black Conditions Blue

Book 2 (14.3) www.automationdirect.com/float-level-switches Level Sensors eLE-67 Prices as of April 27, 2016, 2015. Check Web site for most current prices. Float Level Switches

Agency Approvals UR CSA cURus Class I, Group A,B,C,D / CSA Class I, Group A,B,C,D / Part Number Class II, Group E, F, G / Class II, Group E, F, G / CE (E320431) Class III (2679134) Class III (E366154) (2685021) FLS-VS-100 4 4 FLS-VS-200 4 FLS-VM-100 4 4 4 FLS-VM-200 4 4 4 FLS-VM-300 4 4 4 FLS-VM-400 4 4 4 FLS-VM-500 4 4 FLS-VM-600 4 FLS-VL-010 4 4 4 FLS-VL-020 4 4 4 FLS-VL-030 4 4 4 FLS-VL-040 4 4 FLS-VL-100 4 4 4 FLS-VL-200 4 4 4 FLS-VL-300 4 4 4 FLS-VL-400 4 4 4 FLS-VL-500 4 FLS-VL-600 4 FLS-VL-900 4 FLS-HS-100 4 4 4 FLS-HS-200 4 4 4 FLS-HS-300 4 FLS-HM-100 4 4 4 FLS-HM-200 4 4 4 4 FLS-HM-300 4 4 FLS-HL-010 4 FLS-HL-200 4 4 FLS-BM-100 4 FLS-BM-200 4 FLS-BM-300 4 4 4 FLS-BL-100 4 FLS-VK-100 4 4 FLS-VK-200 4 4 FLS-VK-300 4 4 FLS-HT-100 4 FLS-HT-200 4

Book 2 (14.3) eLE-68 Level Sensors 1-800-633-0405