R640 Servers VS Servers of HPE, H3C, , , Inspur and Sugon

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 Advantages of Dell Servers The perfect balance of 8GB RAID Cache, support more Quick Sync \ 750W Titanium / 5 USB R640 supports 8GB cache performance and density 2.5 "HDD / 25GbE NDC / 8G raid cash / RAID card, supports built-in redundant SD module, supports NVDIMM, supports Quick Sync wireless management Disadvantages of Dell Servers / Supported NVMe quantity, GPU Does not support NVMe, does not Does not support the support GPU, the maximum number of GPU and PCIE memory is 3T slots CPU Model Intel® Xeon® Scalable Processors 1-2 Intel Xeon processors Supports up to 2 Intel® Xeon® Intel Xeon Bronze, Silver, 8100/6100/5100/4100/3100 8100/6100/5100/4100/3100 Skylake processors, Gold, or Platinum processors Series series 4/8/12/16/18/20/22/24/26/28 cores, with a maximum power of 205W

Max CPU Model 8180M 8080 / 8010M Platinum 8180M Intel Xeon Platinum 8180 28C Chipset Intel C621 Intel C621 Intel C621 Intel C624 Memory Model 24 128GB / 2667MHz / LRDIMMs Supports up to 24 128GB / 24 DDR4 memory slots, supporting 24 DDR4 DIMM slots, up to starting April 2019 support 2667MHz / LRDIMM a maximum speed of 2666MT/s, 2666MT/s 2933MHz RDIMMs 32GB / 2667MHZ / RDIMM supporting RDIMM or LRDIMM

Router-switch.com 1

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 Total capacity 3TB 3TB Maximum capacity 3.0TB RDIMMs support up to 768GB. LRDIMMs support up to 1.5TB. 3DS RDIMMs support up to 3TB. (Support is planned for future)

Persistent 12 NVDIMMs, up to 192GB Supports 12 permanent / Not support memory memories with a maximum capacity of 192GB Storage Model 6Gbps SATA controller: Onbord 1 S100i Standard onboard array controller, 12Gbps RAID controller: controller SW RAID S140 1 E208i-a / E208e-p support SATA RAID 0/1/10/5 ThinkSystem RAID 530-8i 12Gbps RAID controller: 1 P408i-a / P408e-p Optional HBA card based on PCIe 12Gb Adapter RAID Controller H730P, 12Gb / s 1 P816i-a dedicated slot for array card, ThinkSystem RAID 730-8i SAS, 6Gb / s SATA, 2GB DDR3 NV support SATA / SAS RAID 0/1/10/5 1GB Cache PCIe 12Gb SDRAM, PCIe, support SAS / SATA Optional based on array card Adapter / SSD; proprietary plug-in Slot array card, ThinkSystem RAID 930-8i RAID Controller H740P, 12Gb / s support RAID0 / 1/10/5/6/50/60 / 2GB Flash PCIe 12Gb SAS, 6Gb / s SATA, 8GB DDR4-2133 1E Adapter NV DRAM, PCIe, support SAS / Optional HBA card and smart array ThinkSystem RAID 930-16i SATA / SSD; card based on standard PCIe slot 4GB Flash PCIe 12Gb RAID Controller H330, 12Gb / s Adapter SAS, 6Gb / s SATA, support SAS / SATA / SSD, no cache, PCIe 12Gbps non-RAID HBA card: internal controller: HBA330 ThinkSystem 430-8i SAS / 12Gb / s SAS, 6Gb / s SATA, No SATA 12Gb HBA Cache, No RAID, Pass through only ThinkSystem 430-16i SAS /

Router-switch.com 2

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 exterN/Al PERC (RAID): RAID SATA 12Gb HBA Controller H840 NVMe PCIe interfaces (non- RAID Controller H840, 2Gb / s SAS, RAID) 6Gb / s SATA, 8GB NV, PCIe, Onboard NVMe interface (4- support SAS / SATA / SSD, port) 0/1/5/6/10/50/60 exterN/Al HBA (non-RAID): 12 Gbps SAS HBA No Cache, No RAID, Pass through only Cache size / 8GB 4GB 2G None, 1GB, 2GB, 4GB maximum Cahce / / flash None (530-8i, 730-8i), Flash protection type backup (930-8i, 930-16i) Battery or battery battery / capacitance capacitor Main technical Controller chip: H730P (LSISAS 12Gb SAS, up to 240 Supports up to 2GB 72-bit wide bus Controller chip: SAS3408 characteristics 3108), H740P (LSISAS 3508), H330 DDR3-1600MHz cache (530-8i), SAS3108 (730-8i), (LSI SAS3008) SAS3508 (930-8i), SAS3516 RAID support: H730P (930-16i), SAS3408 (430-8i), (0/1/5/6/10/50/60), H740P SAS3416 (430-16i) (0/1/5/6 / 10/50/60), H330 RAID support: 530- 8i (0 \ 1 \ (0/1/5/10/50), S140 (0/1/5/10) 10 \ 5 \ 50), 730-8i (0 \ 1 \ 10 \ 5 \ 50), 930-8i (0 \ 1 \ 10 \ 5 \ 50 \ 6 \ 60), 930-16i (0 \ 1 \ 10 \ 5 \ 50 \ 6 \ 60) SD Card Number of SD 2 1 (Optional 2) 2 Does not support SD cards cards

Router-switch.com 3

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 SD card capacity 64GB 8GB / 32GB N / A N / A SD cards can 1 RAID 1 N / A N / A form RAID levels M.2 M.2 Quantity 2 2 N / A 1 or 2 M. 2 single chip 240GB 1.92TB 256G ThinkSystem M.2 CV1 32GB capacity ThinkSystem M.2 CV3 128GB M.2 RAID levels 1 RAID 1 N / A RAID0, RAID1 Network Card Daughter card Four 1GE interfaces, or two 10GE 4x1Gb Optional Flexible LOM 1 onboard 1Gbps management LOM cards (Intel X722, not (NDC card type) plus two 1GE interfaces, or four 2x10Gb / 4x10Gb / 2x25Gb network port can be compatible with 10 / 100MB 10GE interfaces, or two 25GE Optionally expanded via mLOM 4 × speed) interfaces 1GE electrical port or 2 × 10GE ThinkSystem 1Gb 2-port electrical / optical port RJ45 LOM Optional network adapter based on ThinkSystem 1Gb 4-port standard PCIe slot RJ45 LOM ThinkSystem 10Gb 2-port Base-T LOM ThinkSystem 10Gb 2-port SFP + LOM ThinkSystem 10Gb 4-port Base- T LOM ThinkSystem 10Gb 4-port SFP + LOM

ML2 adapters Broadcom NX-E ML2 10Gb 2- Port Base-T Ethernet Adapter

Router-switch.com 4

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 Emulex VFA5.2 ML2 Dual Port 10GbE SFP + Adapter Emulex VFA5.2 ML2 2x10 GbE SFP + Adapter and FCoE / iSCSI SW Intel X710-DA2 ML2 2x10GbE SFP + Adapter Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter Mellanox ConnectX-4 Lx ML2 25Gb 2-Port SFP28 Ethernet Adapter Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter PCIe (occupies a Yes No (embedded, not occupying 4 available PCIe 3.0 slots (2 Yes standard slot) slots) standard slots, 1 array card dedicated slot, 1 network card dedicated slot) GPU Max Supported 1 single width 2 single width Supports 2 single-width GPUs 1 GPU

Router-switch.com 5

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 GPU model NVS310 Nvidia Tesla P4 N / A NVIDIA Quadro P2000 PCIe Quadro P2000 / P4000 Active GPU

FPGA Maximum 0 / N / A N / A Supported FPGA FPGA model 0 / N / A N / A

Hard drive Type (including Front drive bays: Optional 8SFF / 10SFF / 4LFF Supports up to 4LFF front and 2SFF Four 3.5-inch SAS / SATA hot backplane the maximum up to ten 2.5-inch SAS / SATA (HDD chassis, support SATA / SAS / SSD rear expansion; up to 10SFF front plug hard supported hard / SSD), up to ten NVMe SSDs; Optional 10SFF chassis, support and 2SFF rear expansion; supports eight 2.5-inch SAS / SATA disks) up to four 3.5-inch SAS / SATA NVMe / SATA / SAS / SSD SAS / SATA HDD / SSD hard disks hard disk hot plug HDDs; Optional rear 1 SFF or 1 Dual UFF Supports 4 front NVMe hard disks 12 2.5 inches SAS / SATA hard rear-drive bays: Supports SATA M.2 option disk hot plug (10 in front, up to two 2.5-inch SAS / SATA two behind) (HDD / SSD) 10 2.5 inches U.2 NVMe PCIe SSD hot-swap hard disk (support is planned for future) Support hard Yes Yes Yes Yes disk hot swap

Hard disk Model and SAS / SATA / NVMe; 12 8 + 2 + 1 SFF SAS / SATA, 4 LFF, 10 Supports up to 4LFF front and 2SFF 2.5-inch 12Gbps SAS hard configuration quantity NVMe rear expansion; up to 10SFF front disk: and 2SFF rear expansion; supports 300GB 15K, 600GB 15K, SAS / SATA HDD / SSD hard disks 900GB 15K

Router-switch.com 6

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 Supports 4 front NVMe hard disks 300GB 10K, 600GB 10K, Supports SATA M.2 option 900GB 10K, 1.2TB 10K, 1.8TB 10K 3.5-inch 12Gbps SAS hard disk: 300GB 15K, 600GB 15K 2.5-inch 12Gbps NL-SAS hard disk: 1TB 7.2K, 2TB 7.2 3.5-inch 12Gbps NL-SAS hard disk: 1TB 7.2K, 2TB 7.2K, 4TB 7.2K, 6TB 7.2K, 10TB 7.2K 3.5-inch 6Gbps SATA hard disk: 1TB 7.2K, 2TB 7.2K, 4TB 7.2K, 6TB 7.2K, 8TB 7.2K, 10TB 7.2K 2.5-inch 6Gbps SATA hard disk: 1TB 7.2K, 2TB 7.2K 2.5-inch SSD hard disk: SAS interface: HUSMM32 400GB, HUSMM32 800GB, PM1635a 400GB, PM1635a 800GB, PM1633a 3.84TB, PM1633a 7.68 TB SATA interfaces: PM863a

Router-switch.com 7

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 240GB, PM863a 480GB, Intel S3520 240GB, Intel S3520 480GB, NVMe PCIe interfaces: U.2 PX04PMB 800GB, U.2 PX04PMB 1.6TB, U.2 PX04PMB 960GB, U.2 PX04PMB 1.92TB, U. 2 PM963 1.92TB, U.2 PM963 3.84TB Chassis Dimensions 43.4 * 4.3 * 75.6; 21.3kg SFF: 4.29 x 43.46 x 70.7 cm 42.88mm (H) * 434.59mm (W) * 1U height LFF: 4.29 x 43.46 x 74.98 cm 768.3mm (D) (without security : 43 mm (1.7 in) panel) width: 434 mm (17.1 in) 42.88mm (H) * 434.59mm (W) * depth: 715 mm (28.1 in) 780.02mm (D) (with Security panel) Ventilation Air-cooled Forward wind Forward wind Front and rear ventilation method Temperature Equipment 10 ° C to 35 ° C 10 ° C to 35 ° C 5 ° C to 45 ° C ASHRAE Class A4: 5 ° C - 45 ° operating C (41 ° F - 113 ° F); for temperature altitudes above 900 m (2,953 range (Celsius) ft), decrease the maximum ambient temperature by 1 ° C for every 125-m (410-ft) increase in altitude ASHRAE Class A3: 5 ° C-40 ° C (41 ° F-104 ° F); for altitudes above 900 m (2,953 ft), decrease the maximum

Router-switch.com 8

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 ambient temperature by 1 ° C for every 175-m (574 -ft) increase in altitude ASHRAE Class A2: 10 ° C-35 ° C (50 ° F-95 ° F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 ° C for every 300- m (984-ft) increase in altitude Equipment 10% to 80% 8%-90% N/A ASHRAE Class A4: 8%-90% working (non-condensing); maximum humidity range dew point: 24 ° C (75 ° F) ASHRAE Class A3: 8%-85% (non-condensing); maximum dew point: 24 ° C ( 75 ° F) ASHRAE Class A2: 8%-80% (non-condensing); maximum dew point: 21 ° C (70 ° F) Hot- Nominal power Titanium 750W, HPE Universal Slot Redundant Optional Platinum Level 550W / ThinkSystem 550W (230V / swappable of single power Platinum 495W, 750W, 1100W Power Module 500 Watt / 800 800W / 1200W 1 + 1 redundant 115V) Platinum Hot-Swap power supply (W) and 1600W Watt / 1600 Watt power supply Power Supply supplies Support hot-swappable redundant ThinkSystem 750W (230 / fans 115V) Platinum Hot-Swap Power Supply ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply

Router-switch.com 9

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 ThinkSystem 1100W (230V / 115V) Platinum Hot-Swap Power Supply Quantity 2 1 or 2 2 2 Dual power Redundancy Redundancy Redundancy N + N mode

Input method 220V AC / 48VDC / 380HVDC / 240VAC / 48VDC / 380VDC N/A 100-127 (nominal) V AC; 50 240HVDC Hz / 60 Hz 200-240 (nominal) V AC; 50 Hz / 60 Hz 180-300 V DC (supported in China only) PCI-E (I / O) Quantity 3 PCIe 3.0 x16 slots 3 4 available PCIe 3.0 slots (2 Supports up to 4 PCIE 3.0 standard slots, 1 array card slots (including 1 dedicated dedicated slot, 1 network card RAID adapter PCIE) dedicated slot) LOM card slot Slot 1: PCIe 3.0 x8, ML2 x8, or ML2 x16; low profile Slot 2: PCIe 3.0 x16 or x8; low profile or full -height, half- length Slot 3: PCIe 3.0 x16; low profile Slot 4: PCIe 3.0 x8 (dedicated to an internal storage controller) USB Quantity 5 5 4 USB 3.0 (2 rear, 2 built-in); Total 4 USB ports

Router-switch.com 10

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 Front panel: 1x USB 2.0 port with XClarity Controller access, 1x USB 3.0 port Rear panel: 2x USB 3.0 ports Out-of-band Yes or No Yes Yes Yes Yes management Main function IPMI 2.0 Compliant HPE iLO Standard with Smart HDM agentless management tool XClarity Controller (XCC) iDRAC9 (Express Edition, Configuration (embedded), HPE (with independent management Standard, Advanced, and Enterprise Edition) with Lifecycle OneView Standard (download port) and H3C FIST management Enterprise Controller required) (standard), HPE iLO include Standard version Optional Quick Sync 2 Wireless Advanced, features by default. You can Module HPE iLO Advanced Premium choose to upgrade to Security Edition, and HPE Advanced or Enterprise OneView Advanced (optional) through Features on Demand (FoD). Support mobile management functions (Xclarity Mobile App + front USB interface connection). Mobile App supports Android or iOS Energy Yes or No Yes Yes Yes Yes, Lenovo XClarity Energy management Manager System cooling fan Air baffle, vector heat dissipation 7 Unknown 7 hot-swappable fans, support N + 1 redundancy, 5 with 1 CPU, 7 with 2 CPU LCD display Optional Systems Insight Display Yes N / A, using Light path diagnostics

Router-switch.com 11

Model Dell PowerEdge R640 HPE DL360 G10 H3C UniServer R4700 G3 Lenovo ThinkSystem SR630 Host front panel with keyhole and Yes Yes Yes Support, optional lock panel key (ThinkSystem 1U Security Bezel) Other Cryptographically signed / CCC, CECP, SEPA certification Lenovo AnyBay is a unique firmware; Hardware Root of Trust; drive bay type that allows a Secure Boot; System Lockdown; choice of drive interface System Erase; types in the same drive bay: OpenManage connections: SAS drives, SATA drives, or N/Agios & N/Agios XI, Oracle U.2 NVMe PCIe drives. Enterprise Manager, HP Operations Manager, IBM Tivoli Netcool / OMNIbus, IBM Tivoli® Network MaN/Ager, CA Network and Systems Management

Router-switch.com 12

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 Advantages of Dell Servers The perfect balance of Security features; more choices R640 supports NVMe Support high TDP CPU / performance and density on SDS boot media; network (above 165W); all PCIe slots daughter card supports are x16; Inspur does not 25Gb; DELL H740P can be support IDSDM configured with up to 8GB cache capacity DELL supports dual SD cards, dual M.2 SATADOM Quick Sync 2 intelligent management panel supports NVDIMM Disadvantages of Dell Servers / RAID card does not support / / / super capacitors

CPU Model Intel® Xeon® Scalable Processors Supports 1 to 2 Intel® Xeon® Intel Skylake 3/4/5/6/8 Intel® Xeon® processor / 8100/6100/5100/4100/3100 3100, 4100, 5100, 6100, 8100 purley series with a Series series scalable processors maximum TDP of 165W

Max CPU Model 8180M 8180 (28c / 2.5GHz) N/A / /

Chipset Intel C621 Lewisburg-2 C622 / C624 / / Memory Model 24 128GB / 2667MHz / LRDIMMs 24 DDR4 DIMM slots, up to 24 memory slots, 24 DIMM DDR4, support 24 memory starting April 2019 support 2666MT/s supporting up to RDIMM / LRDIMM, slots 2933MHz RDIMMs DDR4-2666 memory. maximum memory working supporting Supports RDIMM, frequency 2666MHz RDIMM, LRDIMM memory. LRDIMM,

Router-switch.com 13

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 NVDIMM and NVDIMM-N

Total capacity 3TB RDIMM: 24 32GB RDIMMs, with Single 128G support up / 3TB 2 processors, the maximum to 3TB memory is 768GB. LRDIMM: 24 64GB LRDIMMs, with 2 processors, the maximum memory is 1536GB.

Persistent 12 NVDIMMs, up to 192GB / / Which supports 12 AEP / memory memory modules (requires Cascade CPU) Storage Model 6Gbps SATA controller: Onbord SR130-M (LSI SAS3008) does not External Raid / SAS / / controller SW RAID S140 support RAID, supports IT work card: 12Gbps RAID controller: mode, and supports iBMC out- RAID card controllers RAID Controller H730P, 12Gb / s of-band management. SAS3108, SAS, 6Gb / s SATA, 2GB DDR3 NV SR430C-M (LSI SAS3108) can SAS3008IMR, 9361-8i, SDRAM, PCIe, support SAS / SATA support RAID 0/1/10/5/50/6/60, PM8060; / SSD; support super capacitor RAID Controller H740P, 12Gb / s protection, and support iBMC SAS card controllers SAS, 6Gb / s SATA, 8GB DDR4- out-of-band management. 9400-8i, SAS3008IT 2133 NV DRAM, PCIe, support SAS / SATA / SSD; onboard SATA RAID Controller H330, 12Gb / s controllers: SAS, 6Gb / s SATA, support SAS / soft RAID through RAID

Router-switch.com 14

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 SATA / SSD, no cache, PCIe key internal controller: HBA330 12Gb / s SAS, 6Gb / s SATA, No Cache, No RAID, Pass through only external PERC (RAID): RAID Controller H840 RAID Controller H840, 2Gb / s SAS, 6Gb / s SATA, 8GB NV, PCIe, support SAS / SATA / SSD, 0/1/5/6/10/50/60 external HBA (non-RAID): 12 Gbps SAS HBA No Cache, No RAID, Pass through only Cache size / 8GB 0 / 4GB N/A / / maximum Cahce / capacitance N/A / / protection type Battery or battery capacitance N/A / / capacitor Main technical Controller chip: H730P (LSISAS Support RAID Configurable storage / / characteristics 3108), H740P (LSISAS 3508), 0/1/00/5/6/10/50/60, hard disk controller with cache, H330 (LSI SAS3008) hot backup, read and write support for power RAID support: H730P cache, data power-down failure protection (0/1/5/6/10/50/60), H740P protection, CacheCade, disk module (0/1/5/6 / 10/50/60), H330 inspection, automatic SMART

Router-switch.com 15

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 (0/1/5/10/50), S140 (0/1/5/10) scan, hard disk energy saving, hard disk roaming, etc. SD Card Number of SD 2 Does not support SD cards N/A N/A / cards SD card capacity 64GB N / A N/A / / SD cards can 1 N / A N/A / / form RAID levels M.2 M.2 Quantity 2 2 2 2 SATA M.2 SSDs / M. 2 single chip 240GB N / A N/A / / capacity M.2 RAID levels 1 N / A N/A / / Network Card Daughter card Four 1GE interfaces, or two 10GE Onboard network card: 2 10GE Support 2 OCP Supports two OCP network / (NDC card type) plus two 1GE interfaces, or four interfaces and 2 GE interfaces network card slots, card slots, 10GE interfaces, or two 25GE SM211-2 * GE Intel i350 chip 2 OCP rate 10Gb / s, optional external plug-in interfaces port 1Gb Base-T 25Gb / s; OCP-C dual 10 Gigabit SM212-4 * GE Intel i350 chip 4 standard PCIE network optical network card, four port 1Gb Base-T card: rate 10 Gigabit optical network SM233 2 * 10GE Intel X540 chip 1/10/25/40/100 Gb / s card, dual 10 Gigabit 2 port 10Gb Base-T electrical port network SM210 4 * GE Qlogic Broadcom card, four Gigabit electrical 5719 chip 4-port 1Gb Base-T port network card Dual 10 Gigabit electrical port network card, 25G dual port network card

Optional OCP-A + B dual 100G fiber optic network

Router-switch.com 16

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 card PCIe (occupies a Yes Intel I350 4-port 1Gb Base-T Supports 5 PCI-E slots / / standard slot) network card Intel I350 2-port 1Gb Base-T network card Intel X540 2-port 10Gb Base-T network card Intel X710 2-port 10Gb SFP + network card Intel X710 4-port 10Gb SFP + network card single or dual port Emulex / Qlogic 16Gb / 8Gb FC HBA card GPU Max Supported 1 single width Supports up to 1 single-width N/A / / GPU GPU

GPU model NVS310 nVidia Tesla P4 N/A / /

FPGA Maximum 0 N/A N/A / / Supported FPGA

Router-switch.com 17

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 FPGA model None N/A N/A / /

Hard drive Type (including Front drive bays: 10 2.5-inch hard drives (6 ~ 8 Front: Supports up to 3.5 * 4 + 2.5 / backplane the maximum up to ten 2.5-inch SAS / SATA NVMe SSD hard drives and 2 ~ 4 Supports up to 10 front * supported hard (HDD / SSD), up to ten NVMe SAS / SATA hard drives) 2.5-inch hard disks, 2-4SATA, compatible with 4 disks) SSDs; or supports 2.5 ″ × 2 SATA NVMe SSDs up to four 3.5-inch SAS / SATA 8 2.5-inch SAS / SATA / SSD hard / SAS + 8 × NVMe, -4SATA, compatible with 1 HDDs; drives (4 NVMe SSD hard drives) supports hot-swap NVMe SSD rear-drive bays: or hybrid configuration, Up to two 2.5-inch SAS / SATA 4 3.5-inch SAS / SATA / SSD hard 4 3.5-inch hard disks + Supports up to 2.5 * 10+ 2.5 (HDD / SSD) drive 2 2.5-inch SSDs, and * supports 10 NVMe 2-10NVMe, supports 8 SAS / SSDs Flash SSD configuration -10SAS / SSD, compatible rear: 2.5 ″ × 2 SATA SSD with 8 NVMe SSD supports hot swap Support hard Yes Yes N/A / / disk hot swap

Hard disk Model and SAS / SATA / NVMe; 12 300GB / 600GB / 900GB / 1.2TB Front: Up to 10 front / / configuration quantity 10K to SAS 2.5-inch hard drives, or 300GB / 600GB 15K to SAS 4 3.5-inch hard drives + 2TB / 3TB / 4TB 7.2K to NL-SAS 2 2.5-inch 1TB / 3TB / 4TB 7.2K to SATA SSDs. Supports 10 1.2TB / 1.6TB / 1.92TB / 240GB / NVMe SSDs with full 3.84TB / 480GB / 800GB / 960GB flash configuration SSD and rear position: up

Router-switch.com 18

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 supports NVMe 1.2TB / 2TB / to 2 2.5-inch SSDs 3.2TB / 1.6TB / 800GB SSD Chassis Dimensions 43.4 * 4.3 * 75.6; 21.3kg 3.5-inch hard disk case: 43mm × Main unit: 435mm / / 436mm × 748mm (1.69in. × (width) × 43.05mm 17.17in. × 29.45in.) (height) × 750.5mm 2.5-inch hard disk case: 43mm × (depth) 436mm × 708mm (1.69in. × 17.17in. × 27.87in.) Outer packaging: 651mm (width) × 307mm (height) × 971mm (depth) Ventilation Air-cooled Front and rear ventilation Air-cooled / / method Temperature Equipment 10 ° C to 35 ° C Operating temperature: 5 ° C to 10 ℃ -35 ℃ / / operating 45 ° C (41 ° F to 113 ° F) (in temperature accordance with ASHRAE CLASS range (Celsius) A3 and A4 standards) Equipment 10% to 80% Operating humidity: 8% RH to 20% -80% relative / / working 90% RH non-condensing humidity humidity range Hot- Nominal power Titanium 750W, 550W AC Platinum Power Supply Supports high-voltage Platinum redundant dual / swappable of single power Platinum 495W, 750W, 1100W DC and titanium power power, can support Active- power supply (W) and 1600W supplies, supports Standby, high voltage DC supplies 550W / 800W / 1200W and other functions, can and above output support single and dual power supplies power; support PMbus, Ruineng Smart Power

Router-switch.com 19

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 power management technology Quantity 2 2 2 2 / Dual power Redundancy 1 + 1 redundancy Redundancy / / mode

Input method 220V AC / 48VDC / 380HVDC / 110V / 220V AC or 240V / 380V Support HVDC / / 240HVDC DC or -48V DC PCI-E (I / O) Quantity 3 PCIe 3.0 x16 slots Supports up to four PCIe 3.0 x8 Supports up to 3 Supports up to 3 PCIE / PCIe expansion slots, one of standard PCIe slots and expansions, including 1 full- which is a PCIe expansion card 2 OCP slots height half-length + 2 half- dedicated to a RAID card, and height half-length the other three standard PCIe expansion slots. riser riser cards that can be PCIe riser module 1, supports a expanded: 1 PCIe3.0 x8 + x1 half-height, half-length PCIe3.0 half-height half-length; x16 standard card (the sigN/Al is 1 PCIe3.0 x16 full-height PCIe3.0 x16). half-length; 1 PCIe3.0 x16 PCIe riser module 2, supports half height half length one half-height half-length PCIe3.0 x16 standard card (sigN/Al is PCIe3.0 x16) and one full-height half-length PCIe3.0 x16 standard card (sigN/Al is PCIe3.0 x8). The PCIe expansion slot supports Huawei's independent

Router-switch.com 20

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 development of PCIe SSD memory cards, which can greatly improve I / O performance in application areas such as search, cache, and download. USB Quantity 5 Front panel provides 1 USB 2.0 3.5x4 models: / / port, 1 USB 3.0 port 2 rear USB3.0 + 1 front Rear panel provides 2 USB 3.0 USB 3.0 + 1 front USB ports 2.0 + 1 built-in USB3.0 Built-in 1 USB 3.0 port 1 front VGA, 1 rear VGA 2.5x10 models: 2 Rear USB3.0 + 2 front USB 2.0 + 1 built-in USB3.0 1 front VGA, 1 rear VGA Out-of-band Yes or No Yes Yes Yes / / management Main function IPMI 2.0 Compliant UEFI Integrated 1 Integrated independent / iDRAC9 (Express Edition, iBMC independent management network port, Enterprise Edition) with Lifecycle uses independent interfaces, 1000Mbps network can support management Controller supports SNMP v1 / v2c / v3, interface, dedicated functions such as redfish, Optional Quick Sync 2 Wireless IPMI 2.0, Redfish 1.0, and for remote IPMI 2.0, KVM over IP, Module provides features such as GUI, management of IPMI virtual media; support data virtual KVM, virtual media, SOL, network port management intelligent power, remote multiplexing function; control, and hardware support Inspur ICM server

Router-switch.com 21

Model Dell PowerEdge R640 Huawei RH1288H v5 Inspur NF5180 M5 Inspur Yingxin server Sugon I610- SA5112M5 G30 monitoring. management, deployment Supports NCSI. software Supports Huawei eSight management software and integration with third-party management systems such as VMware vCenter, SystemCenter, and N/Agios. Energy Yes or No Have Have N/A / / management System cooling fan Air baffle, vector heat dissipation 7 hot-swappable fans, support System fans (7) / / single fan failure LCD display Optional no N/A / / Host front panel with keyhole Have Support (security panel) N/A / / and key Other Cryptographically signed N/A N/A / / firmware; Hardware Root of Trust; Secure Boot; System Lockdown; System Erase; OpenMaN/Age connections: N/Agios & N/Agios XI, Oracle Enterprise MaN/Ager, HP Operations MaN/Ager, IBM Tivoli Netcool / OMNIbus, IBM Tivoli® Network MaN/Ager, CA Network and Systems Management

Router-switch.com 22

Related Sources Learn More about the server comparisons of Dell and competitors: Dell T140 Servers VS Lenovo ST50 Servers Dell T340 Servers VS Lenovo ST250 Servers Dell T440 Servers VS Lenovo ST550/ST558 Servers Dell T640 Servers VS HPE ML350 Servers VS Lenovo ST550 Servers Dell R240 Servers VS Lenovo SR150 Servers Dell R340 Servers VS Lenovo SR250 Servers Dell R440 Servers VS H3C R2700 Servers VS Lenovo SR530/SR570 Dell R540 Servers VS H3C R2900 Servers VS Lenovo SR550/SR590 Servers Dell R740 Servers VS Servers of HPE, H3C, Lenovo, Huawei, Inspur and Sugon Dell R840 Servers VS HPE DL560 VS Lenovo SR850 VS Huawei RH2488 VS Inspur NF8260 Servers Dell R940 Servers VS Servers of HPE, H3C, Lenovo, Huawei, Inspur and Sugon

Router-switch.com 23

Where To Buy

Want to buy this series of products? Visit: Dell PowerEdge R640 Server and HPE DL360 G10; or please contact:

● Tel: +1-626-239-8066 (USA) +852-3050-1066 / +852-3174-6166

● Fax: +852-3050-1066 (Hong Kong)

● Email: [email protected] (Sales Inquiries)

Why Router-switch.com As a leading network hardware supplier, Router-switch.com focuses on origiN/Al new ICT equipment of Cisco, Huawei, HPE, Dell, Uniview, Juniper, Fortinet, etc.

Router-switch.com 24