Architect Series® Traditional Awning Window
Total Page:16
File Type:pdf, Size:1020Kb
Architect Series® Traditional Awning Window Product Selection Guide Sound Transmission Class/Outdoor-Indoor Transmission Class .......................................................................AW-2 Size and Performance Data ....................................................................................................................................AW-2 Features and Options ..............................................................................................................................................AW-3 Combination Assemblies ..............................................................................................................................AW-4 Glazing Performance .....................................................................................................................................AW-5 Products with Impact-Resistant Glass .......................................................................................................AW-10 Grille Types Grille Profiles .......................................................................................................................................................... AW-11 Typical Grille Patterns ........................................................................................................................................... AW-12 Size Tables Awning .................................................................................................................................................................... AW-13 Large Awning ......................................................................................................................................................... AW-14 Design Data Awning .................................................................................................................................................................... AW-15 Large Awning ......................................................................................................................................................... AW-16 Detailed Product Descriptions Clad ......................................................................................................................................................................... AW-17 Wood ...................................................................................................................................................................... AW-18 Unit Sections Wood Collection ................................................................................................................................................... AW-19 Clad ......................................................................................................................................................................... AW-20 Wood ...................................................................................................................................................................... AW-21 Large Awning—Clad .............................................................................................................................................. AW-22 Large Awning—Wood ........................................................................................................................................... AW-23 Supporting documents for this product: Test Reports: https://media.pella.com/professional/adm/CertificationReports/Test_Reports_AS-Clad.pdf CSI Specs (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Wood-CSI_Specs/08551.rtf AIA Masterspec (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Wood-CSI_Specs/Masterspec/085200_fl.doc Detailed Product Description (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Clad-Wood/AST-AW-C.rtf Size Tables (requires appropriate CAD software to read and use): https://media.pella.com/professional/adm/Clad-Wood/ASCAWE_D.dwg CAD cross sections (requires appropriate CAD software to read and use): https://media.pella.com/professional/adm/Clad-Wood/ASCAW3a_D.dwg 3D & BIM (requires appropriate software to read and use): https://media.pella.com/professional/adm/RevitFiles/AS-Revit/Window-Awning-Pella-Architect_Series.zip Sketchup (requires appropriate software to read and use): https://media.pella.com/professional/adm/Clad-Wood/PellaSKP_ArchitectSeries_Traditional_Awning.zip Combination Recommendations: https://media.pella.com/professional/adm/Clad-Wood/D_Combinations.pdf Installation Details: https://media.pella.com/professional/adm/Clad-Wood/F_InstallationDetails.pdf The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information. Microsoft and Microsoft Word are registered trademarks of Microsoft Corp. Pella 2021 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com AW-1 Architect Series® Traditional Awning Window Size and Performance Data Awning Clad Wood Sizes Standard vent / fixed sizes l l Special sizes available l l Performance 1 CW40 – CW50 CW40 – CW50 Meets or Exceeds AAMA / WDMA Ratings Hallmark Certified Hallmark Certified Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure) 0.05 0.05 Water Resistance 7.5 psf 7.5 psf Design Pressure 40-50 psf 40-50 psf LC+60/-60 – LC+75/-85 Products with Impact-Resistant Glass — Hallmark Certified Other Performance Criteria Forced Entry Resistance Level (Minimum Security Grade) 2 10 10 Large Awning Sizes Standard Vent Sizes l l Special Sizes Available l l Performance 1 LC40 LC40 Meets or Exceeds AAMA / WDMA Ratings Hallmark Certified Hallmark Certified Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure) 0.05 0.05 Water Resistance 7.5 psf 7.5 psf Design Pressure 40 psf 40 psf LC+60/-60 – LC+75/-85 Products with Impact-Resistant Glass — Hallmark Certified Other Performance Criteria Forced Entry Resistance Level (Minimum Security Grade) 2 10 10 Operating Force (lb) Initiate Motion / Maintain Motion (of Hallmark tested size and glazing) 4 15 / 6 15 / 6 Sound Transmission Class / Outdoor-Indoor Transmission Class Glazing System Frame Size Overall Exterior Interior STC OITC Product Third Pane Tested 3 Glazing Glass Glass Rating Rating Thickness Thickness Thickness Thickness Architect Series Clad Vent with Integral Grilles Window 53" x 29" 11/16" 2.5mm 2.5mm — 27 24 59" x 23" 11/16" 5mm 3mm — 33 29 Vent with Removable or No Grilles 53" x 29" 11/16" 2.5mm 2.5mm — 27 23 59" x 23" 11/16" 5mm 3mm — 32 27 59" x 23" 11/16" 3mm 6.0mm PVB — 33 28 Fixed with Integral Grilles 47" x 59" 11/16" 3mm 3mm — 30 27 Fixed with Removable or No Grilles 47" x 59" 11/16" 3mm 3mm — 29 24 47" x 59" 11/16" 5mm 3mm — 31 27 47" x 59" 11/16" 3mm 6.0mm PVB — 32 28 Architect Series Clad Vent with Removable or No Grilles Window with 59" x 23" 11/16" 3mm 7.6mm PVB — 35 30 Impact-Resistant Glass 53" x 29" 1" 5mm 10.1mm SGP — 35 31 Fixed with Removable or No Grilles 47" x 59" 11/16" 3mm 7.6mm PVB — 33 29 53" x 53" 1" 5mm 10.1mm SGP — 35 30 (—) = Not Available (3) ASTM E 1425 defines standard sizes for acoustical testing. Ratings achieved at that size are (1) Maximum performance for single unit when glazed with the appropriate glass thickness. representative of all sizes of the same configuration. See Design Data pages in this section for specific product performance class and grade values. (4) Glazing configurations may result in higher operational forces. Values shown are for standard and special sizes; Custom sizes may not have the same values. NOTE: Performance with additional options may not be the same as Standard and Special size Contact your local sales representative for complete information. units. Please contact your local Pella representative for complete information. (2) The higher the level, the greater the product’s ability to resist forced entry. rev. 08/06/21 Pella 2021 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com AW-2 Architect Series® Traditional Awning Window Features and Options Standard Options / Upgrades Glazing Glazing Type Dual-Pane Insulating Glass Triple-Pane Insulating Glass Insulated Glass Options/Low-E Types SunDefense™ Low-E AdvancedComfort Low-E Advanced Low-E NaturalSun Low-E Clear (no Low-E coating) Additional Glass Options Tempered Glass Obscure Glass 1 Annealed Glass Low-E Tinted Glass (Bronze, Gray and Green) Non-Impact Laminated Dual-Pane Insulating Glass Impact-Resistant Glass (Laminated Dual-Pane Insulating Glass) Gas Fill/High Altitude Krypton 2 Argon High altitude High Altitude with Argon 3 Wood types Pine Mahogany, Douglas Fir Exterior EnduraClad Plus protective finish EnduraClad– protective finish Factory Primed Pine wood exterior Unfinished Mahogany wood exterior Cladding Colors 1 Standard colors Custom Colors Interior Unfinished Wood Factory primed 4 , Factory prefinished paint 4, Factory prefinished stain Hardware Hardware Finish Bright Brass, Satin Nickel, Oil-Rubbed Bronze, Antique Brass, Distressed Bronze, Distressed Champagne, White, Brown or Matte Black Nickel Sash Locks SureLock® System, Unison Lock System 5 — Hinging Awning—Stainless Steel — Large Awning—Wash Hinge — Impact-Resistant—Wash Hinge — Grilles Integral Light Technology® Grilles — Traditional, Prairie, Top