Combined Sewer Overflow Technology Fact Sheet Alternative Disinfection Methods

Total Page:16

File Type:pdf, Size:1020Kb

Combined Sewer Overflow Technology Fact Sheet Alternative Disinfection Methods United States Office of Water EPA 832-F-99-033 Environmental Protection Washington, D.C. September 1999 Agency Combined Sewer Overflow Technology Fact Sheet Alternative Disinfection Methods DESCRIPTION While chlorine disinfection is the most common method used to kill pathogenic microorganisms at Combined sewer overflows (CSOs) occur when wastewater treatment plants, this methodology flows exceed the hydraulic capacity of either the may not be feasible at all CSOs for several wastewater treatment plant (WWTP) or the reasons, including: collection system that transports the combined flow of storm water and sanitary sewage to the • CSOs occur intermittently and their flow WWTP. When an overflow occurs, the excess rate is highly variable, thus making it flows tend to be discharged into a receiving body difficult to regulate the addition of of water. CSOs typically discharge a variable disinfectant. mixture of raw sewage, industrial/commercial wastewater, polluted runoff, and scoured materials • CSOs have high suspended solids that build up in the collection system during dry concentrations. weather periods. These discharges contain a variety of pollutants that may adversely impact the • CSOs vary widely in temperature and receiving water body, including pathogenic bacterial composition. microorganisms, viruses, cysts, and chemical and floatable materials. Health risks associated with • Residual disinfectants from chlorine bacteria-laden water may result through dermal disinfection may be prohibited from contact with the discharge, or through ingestion of receiving waters. contaminated water or shellfish. • CSO outfalls are often located in remote Preliminary reduction of microorganisms and areas and thus may require automated bacteria may be accomplished through physical disinfection systems. reduction of solids in the wastewater, primarily through sedimentation, flotation, and filtration. In addition to these problems, the increased health Following solids reduction, most systems further and safety concerns regarding the use of chlorine reduce bacterial concentrations through to disinfect CSOs has prompted the development disinfection. Disinfection occurs as the of alternative disinfectants, which often pose wastewater is brought into contact with oxidizing fewer problems and hazards. Alternatives to chemicals (such as chlorine, bromine, ozone, chlorine have been developed and evaluated for hydrogen peroxide, and related compounds). continuous disinfection of wastewater discharges to small streams or sensitive water bodies, and are Chlorine has long been the disinfectant of choice now being considered for treatment of CSOs and for most disinfection systems. It offers reliable other episodic discharges. reduction of pathogenic microorganisms at reasonable operating costs. (See EPA's CSO This fact sheet addresses the use of chlorine Technology Fact Sheet 832-F-99-021, dioxide, ozonation, ultraviolet radiation, peracetic Disinfection-Chlorination, for more information). acid and Electron Beam Irradiation (E-Beam) to disinfection is to expose wastewater to a UV treat CSOs. lamp. Historically, most UV disinfection facilities have been designed to utilize Low Pressure Low Chlorine Dioxide Intensity UV lamps for disinfection. For example, low-pressure mercury arc lamps emit Studies have shown that chlorine dioxide is an approximately 90 percent of their light energy effective wastewater disinfectant, although its use around 254 nanometers. in the United States is limited. Chlorine dioxide is applied to wastewater as a gas that is generated UV disinfection works by penetrating the cell on-site using excess chlorine. Although it is walls of pathogenic organisms and structurally relatively easy and economical to produce altering their DNA, thus preventing cell chlorine dioxide is unstable and reactive and any replication and function. No hazardous chemicals transport is hazardous. are produced or released while treating CSOs with UV. Chlorine dioxide is effective at oxidizing phenols, but does not react with aquatic humus to produce Because UV is not a chemical disinfection trihalomethanes (THMs). However, any excess method, it disinfects without altering the physical chlorine remaining from the generation of or chemical properties of water. However, UV chlorine dioxide would react with THM efficiency is affected by suspended solids in the precursors and form THMs. Therefore, operators wastewater, which can scatter and absorb light. must be careful to use the correct amounts of Thus, UV disinfection is not effective in chlorine when generating chlorine dioxide. And wastewaters with a high TSS level. while chlorine dioxide will not react with wastewater to form chloramines, it can produce Peracetic Acid potentially toxic byproducts such as chlorite and chlorate. Peracetic acid (CH3COOOH) (PAA), also known as ethaneperoxoic acid, peroxyacetic acid, or actyl Ozonation hydroxide, is a very strong oxidant. Based on limited demonstration data for disinfection of Ozone is a strong oxidizer and is applied to secondary treatment plant effluent, peracetic acid wastewater as a gas. Its use in CSO treatment appears to be an effective disinfectant and should facilities for wastewater disinfection is relatively be evaluated further for treating CSOs. The new in the United States, and there are few equilibrium mixture of hydrogen peroxide and facilities currently using ozone for disinfection. acetic acid that produces PAA is too unstable and This can be potentially attributed to high initial explosive to transport, and so PAA must be capital costs associated with ozone generation produced on site. The decomposition of PAA equipment. Ozone is equal or superior to chlorine results in acetic acid, hydrogen peroxide and in "killing" power, but it does not cause the oxygen. formation of halogentated organics as does chlorination. Electron Beam Irradiation Ultraviolet (UV) Radiation Electron Beam Irradiation (E-Beam) uses a stream of high energy electrons that are directed into a UV radiation is one example of electromagnetic thin film of water or sludge. The electrons break radiation used for disinfection. UV disinfection apart water molecules and produce a large number incorporates the spectrum of light between 40 of highly reactive chemical species. There are a nanometers and 400 nanometers. Germicidal few reactive species formed during this process properties range between 200 and 300 and include oxidizing hydroxyl radicals, reducing nanometers, with 260 nanometers being the most aqueous electrons and hydrogen atoms. lethal. The primary method for utilizing UV APPLICABILITY As discussed above, Table 1 provides comparative data for chlorine dioxide, peracetic acid, and UV A brief summary illustrating the general radiation to help in determining which compounds applicability of chlorine dioxide, peracetic acid may be most advantageous for specific and UV radiation as alternative CSO disinfectants applications. The following sections summarize is provided in Table 1. While ozonation and the the advantages and disadvantages of using E-Beam process are discussed in this fact sheet as ozonation and E-Beam as alternative CSO potential alternative disinfectants for CSOs, they disinfectants. are not currently considered practical for CSO disinfection and thus they are not included in Ozonation: Advantages Table 1. Because ozone must be generated on-site and the amount generated is dependent on the C More powerful disinfectant than most chlorine demand, ozone is not currently considered compounds. practical for intermittent use in situations where the system would be frequently turned on and off C Inactivates most strains of bacteria and viruses or where there are wide fluctuations in flow rate and is noted for destroying chlorine-resistant and disinfection demand, such as in CSO strains of both. Highly effective for treatment applications. The E-Beam system was Cryptospiridium eradication. initially developed for the disinfection of municipal wastewater treatment plant sludge and C Will oxidize phenols with no negative the destruction of hazardous organic compounds, residuals such as trihalomethane production. and it has not been evaluated for CSO disinfection. EPA will continue to evaluate the E- C Does not produce a disinfection residual that Beam system as a promising innovative would prevent bacterial growth. technology for wastewater technology. C Degenerates into oxygen, which can elevate ADVANTAGES AND DISADVANTAGES oxygen levels in treated water. It does not alter pH of water. As discussed above, one of the primary reasons for seeking alternatives to chlorine disinfection of C Increases coagulation. CSOs is the growing concern over safety in handling gaseous chlorine and the possible toxic C Helps remove iron and manganese. side effects of treatment with chlorine. Studies on alternative disinfectants such as peracetic acid, C Has taste and odor control properties. ozone, E-Beam, and UV, have shown that these alternatives serve as good substitutes for chlorine C Requires short contact time because they produce no toxic byproducts. Although chlorine dioxide does produce Ozonation: Disadvantages byproducts and residuals, the limited use of chlorine dioxide in this country has made it C More costly than traditional chlorinated difficult to assess these byproducts for toxicity. disinfection techniques. The alternatives to chlorine for CSO disinfection C Forms nitric oxides and nitric acid which can are not problem-free, however, and their lead to corrosion.
Recommended publications
  • Infiltration/Inflow Task Force Report
    INFILTRATION/INFLOW TASK FORCE REPORT A GUIDANCE DOCUMENT FOR MWRA MEMBER SEWER COMMUNITIES AND REGIONAL STAKEHOLDERS MARCH 2001 INFILTRATION/INFLOW TASK FORCE REPORT A GUIDANCE DOCUMENT FOR MWRA MEMBER SEWER COMMUNITIES AND REGIONAL STAKEHOLDERS MARCH 2001 Executive Summary This report is the product of the Infiltration/Inflow (I/I) Task Force. It has been developed through the cooperative efforts of the 43 Massachusetts Water Resources Authority (MWRA) member sewer communities, MWRA Advisory Board, The Wastewater Advisory Committee (WAC) to the MWRA, Charles River Watershed Association (CRWA), Fore River Watershed Association (FRWA), Mystic River Watershed Association (MRWA), Neponset River Watershed Association (NRWA), South Shore Chamber of Commerce (SSCC), Massachusetts Department of Environmental Protection (DEP), United States Environmental Protection Agency (EPA), and MWRA. The I/I Task Force recommends implementation of the regional I/I reduction goals and implementation strategies detailed in this report. The report outlines a regional I/I reduction plan with appropriate burdens and benefits for stakeholders. The report is intended to be a guidance document for use by local sewer communities, as well as other regional stakeholders, who may tailor appropriate aspects of the report recommendations to their unique situations. Severe storms in October 1996 and June 1998 led to the unusual circumstance of numerous sanitary sewer overflows (SSOs) from local and MWRA collection systems. In the aftermath of these events, EPA and DEP began an aggressive effort to make MWRA regulate flows from community sewer systems. MWRA recommended cooperative efforts by local collection system operators, as well as regulators and environmental advocates, would be more effective than a prescriptive, enforcement based approach.
    [Show full text]
  • There Are Two Types of Systems Used in The
    Impacts of Sanitary Sewer Overflows and Combined Sewer Overflows on Human Health and on the Environment: a Literature Review Prepared For: Sacramento Area Sewer District Prepared By: Office of Water Programs California State University Sacramento August 2008 Introduction There are two types of public sewer systems used in the United States for collecting and conveying sanitary sewage, combined sewer systems (CSS) and sanitary sewer systems (SSS). Combined sewer systems collect and convey sanitary sewage and urban runoff in a common piping system. Sanitary sewer systems collect and convey sanitary sewage separately from urban runoff. In locations where SSSs exist, urban runoff is collected and conveyed in a separate storm sewer system (EPA, 2004). There are approximately 20,000 SSSs in the U.S. serving 147 million people and approximately 1,100 CSSs serving 43 million people (Meyland et al., 1998). CSSs were built prior to 1900 and were originally designed to convey combined sewage directly to points of discharge, generally into adjacent water bodies. With the advent of sewage treatment, CSS discharge points were redirected to wastewater treatment plant intake points (EPA, 2004). Out of economic necessity, wastewater treatment plants have limited hydraulic and treatment capacity. These plants are generally designed to accommodate diurnal peak sanitary sewage flows and loads, plus a limited additional hydraulic load resulting from wet weather sources. During wet weather events, hydraulic loads in CSSs quickly exceed the treatment and hydraulic capacity of treatment plants, necessitating diversion of part of the flow from the plant. Provisions for flow diversions around the treatment plant are designed into combined sewer systems.
    [Show full text]
  • Camden County Municipal Utilities Authority and 2 Other Permittees
    Intermunicipal Agreements 12/31/15 A'\kj Ar< o ^ezolxtixon of THE CAMDEN COUNTY MUNICIPAL UTILITIES AUTHORITY Authorizing an Intermunidpat Agreement Wilti the Cities of Camden and Gloucester for Preparation uf a NJDEP-Required Combined Sewer Overflow System Management Plan ffR-13;7 -/OS Whereas, the New Jersey Department of Environmental Protection has promulgated new regulations for combined sewer overflow systems that require the CCMUA, Camden City and Gloucester City to develop a new Combined Sewer Overflow System Management Plan for the overall system that comprises the CCMUA's wastewater treatment plant, Camden City's combined sewer overflow system and Gloucester City's combined sewer overflow system; and Whereas, the interconnectedness of these three systems dictates that one plan addresses all three systems; and Whereas, accordingly, the CCMUA, Camden City and Gloucester City have negotiated an intermunicipaf agreement which calls tor the CCMUA tn prepare the WIDFP-required plan tor the three systems, while reaffirming the Cities' ongoing responsibility to own, operate and maintain their own systems Now, Therefore Be it Resolved by the CCMUA Board of commissioners that it authorizes execution of an irttermunicipal agreement with the Cities of Camden and Gloucester for preparation of a NJUtf-retiuired combined Sewer overflow System Management Plan ADOPTED: July 15, 2013 Kifu Midielini, Authority Secretary I hereby certify iiidl the foregoing is a true copy of the Resolution adopted by the members of the Camden County Municipal Utilities
    [Show full text]
  • COMBINED SEWER OVERFLOWS Guidance for Long-Term Control Plan Offbtiw-Maragement MUNICIPAL TECHNOLOGY BRANCH STAPLE HERE
    United States Office Of Water EPA 832-B-95-002 Environmental Protection (4204) September 1995 Agency EPA Combined Sewer Overflows Guidance For Long-TermControl Plan EPA/832-B-95-002 August 1995 Combined Sewer Overflows Guidance for Long-Term Control Plan U.S. Environmental Protection Agency Office of Wastewater Management Washington, DC 20460 Recycled/Recyclablel Printed with VegetableBased Inks on RecycledPaper (20% Postconsumer) NOTICE The statements in this document are intended solely as guidance. This document is not intended, nor can it be relied on, to create any rights enforceable by any party in litigation with the United States. EPA and State officials may decide to follow the guidance provided in this document, or to act at variance with the guidance, based on an analysis of specific site circumstances. This guidance may be revised without public notice to reflect changes in EPA’s strategy for implementation of the Clean Water Act and its implementing regulations, or to clarify and update the text, Mention of trade names or commercial products in this document does not constitute an endorsement or recommendation for use. UNITED STATES ENVIRONMENTAL PROTECTION AGENCY WASHINGTON, D.C. 20460 OFFICEOF MEMORANDUM WATER SUBJECT: Guidance for Long Term Control Plan FROM: Michael B. Cook, Office of Wastewater Management (4201) TO: Interested Parties I am pleased to provide you with the Environmental Protection Agency's (EPA'S) guidance document on the development and implementation of a long-term control plan for combined sewer overflows (CSOs). This document is one of several being prepared to foster implementation of EPA's CSO Control Policy.
    [Show full text]
  • Onsite and Offsite Sanitation Facilities, Including Sewer Systems and Faecal Sludge Management
    Onsite and Offsite Sanitation Facilities, including Sewer Systems and Faecal Sludge Management Mahesh Bhattarai Kathmandu Upatyaka Khanepani Limited (KUKL) 10 August 2017 Kathmandu Types of Toilets used in Nepal Types of toilet used in Nepal according Percentage of Households using different types of toilets to sanitation facilities Types Urban Rural ➢ Flush toilet (public sewerage) Flush Toilet (Sewerage) 30 3 ➢ Flush toilet (septic tank) Flush toilet (Septic tank) 48 30 Ordinary toilet 12 21 ➢ Ordinary toilet Without toilet 9 45 Not stated 1 1 Source: Central Bureau of Statistics (Population Census 2011 : National Report) Onsite Sanitation No Soak away (infiltration) System • Infiltration is achieved through unlined bottom, porous side wall or through all sides Typical roadside settlements and district head quarters of hilly districts Onsite Sanitation is Challenging Terai Very high water table Hill Seepage from hill slope Kathmandu Valley Shallow water extraction for household consumption including drinking, high density-small plot size Common Practices of Onsite Sanitation • Unlined ST with/without soak-away system • Lined ST with/without soak-away system • Type: Pit with single or double vault • Sizes: Vary widely, 1.6 m3 to >11 m3, why? • Need based desludging Onsite Sanitation Consequences • Increased number of source contamination • Higher incidences of water borne diseases especially during wet season Onsite Sanitation: New Initiatives • Partial faecal sludge (FS) treatment in 7 small towns • Full scale FS treatment plant in 4
    [Show full text]
  • A Partially Treated Problem: Overflows from Combined Sewers
    Office of the NEW YORK STATE COMPTROLLER A Partially Treated Problem: Overflows From Combined Sewers New York State Comptroller THOMAS P. DiNAPOLI MAY 2018 Introduction Clean water is vital to public health, environmental and Combined Sewer Systems social well-being, and economic development. One of the most important elements in maintaining clean water by the Numbers in urban areas involves a system of sanitary sewers that direct wastewater to treatment before it is released into surrounding streams, rivers, lakes or oceans. This 10+ million residents responsibility largely falls to local governments. Most large live in communities with urban areas in New York State are served by municipal combined sewer systems. sewer systems, many of which commingle the water from rain and snow melt (“stormwater”) with the wastewater from homes and businesses in “combined sewer systems.” The 46 communities have flows from combined sewers can overwhelm treatment combined sanitary and systems and have a harmful impact on the environment. storm sewers, with Numerous recent news reports have highlighted instances discharge points of systems unable to handle the increased volume 807 where combined sewer and stemming from major weather events. The details are stormwater are released troubling: raw sewage being flushed directly into rivers, streams and lakes that are also used for recreation either partially or wholly including boating, swimming, fishing and in some cases, untreated into a waterbody. drinking water. For citizens who may have been unaware of the situation, this news brings into question long-held gallons assumptions about the natural resources they enjoy on a 6.5 billion of untreated combined sewer daily basis.
    [Show full text]
  • Combined Sewer Overflow Technology Fact Sheet Inflow Reduction
    United States Office of Water 832-F-99-035 Environmental Protection Washington, D.C. September 1999 Agency Combined Sewer Overflow Technology Fact Sheet Inflow Reduction DESCRIPTION Technologies used to reduce inflow include: This fact sheet describes inflow reduction, a • Roof drain redirection. practice designed to minimize the volume of storm water runoff that enters a combined sewer system • Basement sump pump redirection. (CSS). Inflow reduction can result in a lower combined sewer overflow discharge volume and • Flow restriction and flow slipping. may reduce the number of combined sewer overflows. • Storm water infiltration sumps. CSSs are wastewater collection systems designed to • Stream diversion. carry both sanitary sewage and storm water runoff in a single pipe to a wastewater treatment plant. All of these technologies have relatively low costs, During wet weather periods, the hydraulic capacity and most require little maintenance in comparison of the CSS may become overloaded, causing with other CSO controls. overflows to receiving waters at discharge points within the CSS. These overflows are called APPLICABILITY combined sewer overflows, or CSOs. Inflow reduction refers to a set of control technologies that Roof Drain Redirection are used to reduce the amount of storm water entering the CSS from surface sources. Inflow Roof drains often convey rainfall directly from reduction can be a cost-effective way to reduce the residential and commercial roofs into a CSS. Flow volume of flow entering the CSS and the volume into the CSS can be reduced by redirecting roof and/or number of CSOs. It is particularly drains onto lawns or into dry wells or drainfields applicable in CSO communities where open land is where flows can infiltrate into the soil.
    [Show full text]
  • Fecal Sludge Management in Developing Countries a Planning Manual
    First edition 2002 Fecal Sludge Management in Developing Countries A planning manual F l o r i a n K l i n g e l , Agnès Montangero, Doulaye Koné, and Martin Strauss Swiss Federal Institute for Environmental Science & Technology Department for Water and Sanitation in Developing Countries Planning of Fecal Sludge Management Foreword This manual has been produced by SANDEC, the Department of Water and Sanitation in Developing Countries, which is part of the Swiss Federal Institute for Environmental Science and Technology (EAWAG). The main principles for strategic sanitation planing have been adopted from the guide “Strategic Planning for Municipal Planning” from GHK Research and Training Ltd. SANDEC has carried out a case study of fecal sludge management in order to enlighten the issues specific to planning of fecal sludge management. This study took place in the City of Nam Dinh, in Vietnam. The corresponding study report “Septage Management Study Nam Dinh” has been issued by SANDEC and the Nam Dinh Urban Development Project (funded by the Swiss Agency for Development and Cooperation). This manual is a first approach to provide guidance on strategic planning of fecal sludge management. It is intended to further develop this manual. Therefore SANDEC will highly appreciate your comments and suggestions on the manual. For further information and comments, please contact Mr. Martin Strauss at: Swiss Federal Institute for Environmental Science and Technology (EAWAG) Water and Sanitation in Developing Countries (SANDEC) Management of Sludge
    [Show full text]
  • (UV Leds) for Treating Wastewater and Septic Tank Effluent
    water Article Woven-Fiber Microfiltration (WFMF) and Ultraviolet Light Emitting Diodes (UV LEDs) for Treating Wastewater and Septic Tank Effluent Sara E. Beck 1,2,* , Poonyanooch Suwan 1, Thusitha Rathnayeke 1, Thi Minh Hong Nguyen 1,3 , Victor A. Huanambal-Sovero 4 , Boonmee Boonyapalanant 1, Natalie M. Hull 5,6 and Thammarat Koottatep 1 1 School of Environment, Resources, and Development, Asian Institute of Technology, 58 Moo 9, Km. 42, Paholyothin Highway, Khlong Luang, Pathum Thani 12120, Thailand; [email protected] (P.S.); [email protected] (T.R.); [email protected] (T.M.H.N.); [email protected] (B.B.); [email protected] (T.K.) 2 Department of Civil Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada 3 QAEHS—Queensland Alliance for Environmental Health Sciences, The University of Queensland, Brisbane, QLD 4102, Australia 4 Departamento de Ingeniería, Facultad de Ciencias y Filosofía, Universidad Peruana Cayetano Heredia, Lima 15102, Peru; [email protected] 5 Department of Civil, Environmental, and Geodetic Engineering, The Ohio State University, Columbus, OH 43210, USA; [email protected] 6 Sustainability Institute, The Ohio State University, Columbus, OH 43210, USA * Correspondence: [email protected] Citation: Beck, S.E.; Suwan, P.; Rathnayeke, T.; Nguyen, T.M.H.; Abstract: Decentralized wastewater treatment systems enable wastewater to be treated at the source Huanambal-Sovero, V.A.; Boonyapalanant, B.; Hull, N.M.; for cleaner discharge into the environment, protecting public health while allowing for reuse for Koottatep, T. Woven-Fiber agricultural and other purposes. This study, conducted in Thailand, investigated a decentralized Microfiltration (WFMF) and wastewater treatment system incorporating a physical and photochemical process.
    [Show full text]
  • Bayonne, NJ Combined Sewer Overflow Treatment Demonstration Project
    WEFTEC 2016 Bayonne, NJ Combined Sewer Overflow Treatment Demonstration Project: Preliminary Disinfection Results Jurek Patoczka*, John Dening, John Rolak Mott MacDonald, Iselin, New Jersey *email: [email protected] ABSTRACT A CSO pilot treatment program has been completed in Bayonne, New Jersey. The project focused on verifying performance of selected technologies for TSS removal and disinfection under field conditions. Following pretreatment for TSS removal in several alternative processes, the effluent was disinfected with peracetic acid (PAA) or ultraviolet (UV) light utilizing low- pressure and medium-pressure lamps. The test units had a design capacity of between 189 and 3,785 L/min (50 to 1,000 gpm) and were fed from an extensive CSO catchment area. PAA effectiveness was a function of the dose applied as normalized by COD for E. coli, fecal coliforms and Enterococci. Three (3) log reduction (deactivation) was achieved, on average, at 0.010 mg/L PAA dose per mg/L of COD present. Similar deactivation was achieved by UV dose of 25 mJ/cm2 for low-pressure UV system and by 40 mJ/cm2 for medium-pressure system. KEYWORDS: Combined sewer overflow, CSO, peracetic acid, PAA disinfection, UV disinfection INTRODUCTION Bayonne Municipal Utilities Authority (BMUA), NJ, completed a Combined Sewer Overflow (CSO) Long Term Control Plan (LTCP) in 2006, as required by the New Jersey CSO Master General Permit. The LTCP evaluated a variety of technologies and methodologies for addressing combined sewer flows. Rapid treatment for TSS and disinfection at remote end-of-pipe facilities was included as a required element in the LTCP. Due to a lack of independent information, data from individual manufacturers was used as the basis for conceptual sizing of the required facilities.
    [Show full text]
  • The Effect of Physicochemical Properties of Wastewater Flocs on UV Disinfection Following Hydrodynamic Particle Breakage
    The Effect of Physicochemical Properties of Wastewater Flocs on UV Disinfection Following Hydrodynamic Particle Breakage by Robert Best A Thesis Presented to The University of Guelph In partial fulfilment of requirements for the degree of Master of Science in Environmental Science Guelph, Ontario, Canada © Robert Best, November, 2012 ABSTRACT THE EFFECT OF PHYSICOCHEMICAL PROPERTIES OF WASTEWATER FLOCS ON UV DISINFECTION FOLLOWING HYDRODYNAMIC PARTICLE BREAKAGE Robert Best Co-Advisors: Professor Marc Habash University of Guelph, 2012 Professor Steven Liss This study showed that hydrodynamic particle breakage had potential as a method to help improve the disinfection of wastewater effluents. The physicochemical properties of flocs from four distinct effluents sources (combined sewer overflow, settled combined sewer overflow, primary effluent, and final effluent) were compared before and after hydrodynamic treatment. The use of hydrodynamic force to cause floc breakage was shown to be effective, though variable, across all source types. This variation in floc breakage did not have a significant impact on the UV disinfection achieved, as the UV dose kinetics were similar across samples from the same source type. The results of this study demonstrate how the physicochemical properties of floc are affected when exposed to shear force. These observations further the understanding of floc composition and behaviour when shear forces are applied while also providing evidence to indicate this process improves the performance of UV disinfection technology. ACKNOWLEDGEMENTS I would first like to offer my sincere thanks and gratitude to my supervisors, Dr. Steven Liss and Dr. Marc Habash. Your guidance, expertise, and the freedom you granted me has helped me grow as not only a scientist, but also as a person.
    [Show full text]
  • Of 19 Stormwater Management Plan (SWMP) Compliance Calculations Checklist Sheet
    Stormwater Management Plan (SWMP) Compliance Calculations Checklist Sheet Yes/ Comments # No SWMP Review Orientation (Chapter 2 and Chapter 5) 1 Has the applicant identified the type of activity in the submission? (Check one) A Major Land Disturbing Activity - an activity that disturbs 5,000 square feet or greater of land area o SWRv is based on the 90th percentile event (1.2 inches) A Major Substantial Improvement Activity - the building improvement (where the cost exceeds 50% of the market value of the structure before the improvement) and associated land disturbing activity exceed 5,000 square feet o SWRv is based on the 80th percentile event (0.8 inch) o Exempt from the 2-year and 15-year storm-control requirements Mix of Major Substantial Improvement Activity and Major Land Disturbing Activity Public-Right-of-Way o Follow the Maximum Extent Practicable (MEP) Process Unregulated (review for Stormwater Retention Credits only) [Table 2.1 Sizing Criteria for Stormwater Management Performance Requirements, page 8 and Figures 2.3-2.7, pages 15-19] 2 What type of permit is submitted and what types of review are required? (Check One) Raze (R) - ESC Demolition (D) - ESC Excavation (EX) - ESC Sheeting and Shoring (SH) - ESC Foundation to Grade (FD) - ESC, SWM, and GAR Infrastructure (BCIV) - ESC, SWM, and GAR Building (B)- ESC, SWM, and GAR 3 Is the project’s SWMP vested under a regulated transition period? If vested, does the approval extend to the public right-of-way component of the project? (Check the Application for Vesting Status completed by Applicant) The vesting application can be downloaded from the attachment list at http://ddoe.dc.gov/swguidebook [2013 Stormwater Management Rule [2013 SWM Rule Sections 552 Transitions] Page 1 of 19 Stormwater Management Plan (SWMP) Compliance Calculations Checklist Sheet Yes/ Comments # No 4 Is a GAR is required? Does the submission include GAR sheets or an exemption form? The GAR exemption forms can be downloaded from the GAR forms list at http://ddoe.dc.gov/gar [Z.C.
    [Show full text]