Accessible Means of Egress
U.S. A CCESS B O A R D T E C H N I C A L G UIDE Accessible Means of Egress This guide explains requirements in the ADA Standards and referenced sections of the International Building Code (IBC) and was developed in cooperation with the International Code Council. Required Compliance with the IBC [§207] Accessible means of egress must be provided according to the International Building Code (IBC). Issued by the International Code Council (ICC), the IBC addresses the number of means of egress required and technical criteria for them, including fire– resistance rating, smoke protection, travel distance, width, and other features. The Standards currently apply the IBC 2003 edition or the 2000 edition and 2001 supplement. The Access Board plans to update these references. Compliance with a later edition may be possible under the provision for “equivalent Further information on the facilitation” (§103) if it is comparable to, or stricter than, the IBC is available from the, referenced editions. International Code Council (ICC) at (888) 422-7233) or www.iccsafe.org. Means of Egress A means of egress is an unobstructed path to leave buildings, structures, and spaces. A means of egress is comprised of exit access, exit, and exit discharge. Components of a Means of Egress Exit Access The path from any location in a building to an exit Exits Doors to the outside, enclosed exit stairways, and horizontal exits Exit Discharge The path from an exit to a public way such as a street or alley Chapter 4: Accessible Routes Accessible Means of Egress Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)] The IBC requires at least two means of egress from all spaces and buildings with few exceptions.