Your Solution in Mounting Products Solar H2 O .. Conduit HVAC .. Custom Flat Tile Mount Specifications All Patents Pending

5/16”-18 x 1” Machine Bolt ( ) For Rack Attachment Racking of Choice (Not Included) 5/16“ ID Fender Washer (Stainless Steel) (E) 12” x 17“ Flat Concrete Tile - Monier, Eagle, Life Tile, or Hansen 5/16”-18 ID x 1 1/4” OD Sealing Washer (Stainless Steel ) Field Applied Appropriate Sealant EPDM Rubber Counter Flashing 1 1/4” x 5 1/2” Aluminum Post Monolithic Aluminum Tile Cover 5/16” x 3/4” Grade 8 Bolt (Aluminum Flashing) Cast Aluminum Base Plate 5” x 3.5” x 0.5” Peel and Stick Flashing - Under paper above 12” x 11”

(E) Batton Installation Tools Required: (E) Sheathing or OSB Tape Measure with 3/4” bit (E) Tar Paper 2 each 5/16”-18 x 2” TAP Bolts with Toggles Option #1 - 4 each 1/4” x 1 1/2” Lag Bolts Ratchet w/ 1/2” & 7/16” Sockets Option #2 Block Between Rafters & Lag Caulking Gun 6 5/8” 1 Tube of Appropriate Sealant Lip of Tile to Center of Post 30 lb felt paper Wisk Broom / Vacuum Roofers Bar / Shingle Ripper

Pull-out (withdrawal) capacities (lbs) in typical : Machine Bolt specifications - 5/16” x 2” (2 each per Mount) 5/16” Toggle (2 each per Mount) Minimum repetitive pull out testing exceeded 1000 lbs in each: 1/2” plywood 1/2” OSB ()

** Note: To maintain waterproofing of substrate it is important to make sure the Peel and Stick Flashing is properly placed over the Mount Base, and under the course of paper above. If the paper above does not reach due to layout, place an ad- ditional piece of roofing paper over the Peel and Stick and un- der the next course of paper above. (See instructions page 4.)

1 Know Your Roof It is a good idea to do a thorough roof evaluation prior to your project installation. At this time you should do a layout on the roof confirming everything on the drawing will fit as it is intended. Any irregularities should be noted now, so that you can deal with them simply on install day. The quality of the roofing should be determined, so that any repairs or replacement can happen before or in conjunction with the installation. Remove a tile and see what is underneath. On a tile roof it is important to know as much as possible about: the manufacturer of the tile, the size of the tile, age of tile, type of substrate (plywood or oriented strand board [OSB]) the rafter size and spacing, age of roof structure, who roofed it, who built it, etc.

Photos should be taken of all of the roof variables and associated with the job for any future reference either short term or long. If the roofing manufacturer is known, it is then easy to obtain the written manufacturer’s installation instructions for the roofing materials you are dealing with. Typically the tile roof manufacturer puts a stamp of some sort on the back of each tile. This stamp can be defined by the roofing yard, or by a little on-line surfing. The manufacturer’s instructions will spell out exactly what does and does not void the warranty of their roofing product. Officially, the roofing manufacturer’s instructions supersede our instructions, as our product is weaving into theirs. It is also important to have their instructions in the job file, for any future reference.

Product Selection Product Includes The Quick Mount Flat Tile Mount is intended to fit within most flat tile roof systems, but The units are sold in 12 packs. Each 12 pack includes the mount- not all. Specifically it is sized to fit within a standard 12” wide x 17” tall flat concrete tile ing hardware, the mount, the substrate waterproofing, and the roof system of either standard weight or light weight. To confirm that the Quick Mount flashing to install 12 mounts, with written instructions. Flat Tile Mount profile will match your roof, it is best to measure an existing roof tile. The “exposed” surface width (exposed surface not including left side gutter) should measure between 10 3/4” and 12” wide. The height should measure 17” +/- 1/2”. [If it turns out Alternative Attachment Methods the roof tiles are a non-standard size and the Quick Mount Flat Tile Mount does not fit, The Flat Tile Mount comes with two alternative rafterless methods the alternative method is to use a Quick Mount Curved Tile Mount instead. In this case, of attachment: Toggle installation or Lag screw installation. The follow the directions for the Quick Mount Curved Tile Mount and omit the step pertaining choice of which to use is based on the substrate. If the substrate to the bending of the flashing. (Coming Soon: Curved Tile Instructional Video at www. is Oriented Strand Board, use the toggle bolt method. If the sub- quickmountpv.com/tech.php) strate is ½” plywood or greater, use the 4 each lag bolts into the decking. Of course, if there is a rafter at the location of the mount Exposure 10 3/4” to 12” it is advised to use a longer lag bolt and anchor into the rafter itself when available. It is also possible to install blocks between the rafters and then lag into the blocks. Height extensions are not for use with this product. Custom lengths can be ordered. Bottom Edge View of Flat Tile

Toggle Instructions: Waterproofing 1. Drill ¾” (19mm) diameter hole. On a tile roof it is actually the building paper below the tiles that is waterproof. The tiles are 2. Hold the metal channel flat alongside plastic straps and considered water resistant. It is assumed that water will travel under the tiles. The tiles are slide channel through pre-drilled hole. With one hand, there for aesthetics, thermal absorbtion, and to protect the building paper from U.V. and the pull ring so metal channel rests flush behind OSB elements. It is imperative to follow standard roofing practices with the paper. The Peel and sheathing. Slide plastic cap along straps with other Stick Flashing that we provide needs to go over our Mounting Base Plate with 1” minimum hand until flange of cap is flush with roof decking. sticking to the roof paper below the mount. On the top side of the mount, the Peel and Stick 3. Place thumbs between straps. Push thumbs side to must extend under the existing lap in the paper course directly above the mount. In the com- side, snapping off straps level with flange of cap. mon occurrence that the paper is too far up the roof to reach, you must supply and install 4. Prepare Base Plate as per instructions pg.4 photo 4 another piece of building paper (usually 30 lb.) under the row of paper above, and over the 5. Place Base Plate over flange, insert Bolt and tighten top 2 of Peel and Stick Flashing. This paper should be wider than the Peel and Stick until snug against roof deck OSB, then stop. Flashing, and either stapled down or nailed. If a baton board is in the way, pry it up and slip the paper under the baton. How Many Mounts Per Module? IBC There are two questions that must be asked when adding anything to a roof. International SBC Building 1. Can the roof / building / foundation handle the additional load? NRCANational 2. What is to keep the new load from blowing away? Roong Code State Contractors Building It is assumed that a licensed solar installer can answer these questions. If he Association Code / she can’t, he / she will need to find somebody that can. A licensed engineer is the easiest solution. Some of the racking manufacturers have guides to cal- Asphalt IRC Roong culating a code compliant install as well. Many variables must be considered International Manufacturers and determined to complete the calculation. The spacing between mounts has Residential ARMA Association the variables of: strength of rail, distance between parallel rails, cantilever of AHJ Code modules over rails, pull out strength of mount, slope of roof, height of roof, wind Authority zone, roof type, structural integrety of roof framing, etc. The only values in the Sheet Metal & Having National variables above that we can provide is pull out strength and of mount. We SMACNA Jurisdiction Fire provide structural test reports on all of our mounts as needed. You will need to do Air Conditioning Contractors’ Protection the calculation of variables as you are the only one who knows them all. Association National Further Resources Association OSHA NFPA In the process of all the research we have done, we came up with what we call International the “Wheel of Accountability”. It is a graphical look at the many official entities Code that govern how waterproofing should be done. At our web site you can click MANUFACTURERROOFING Council on any wedge of the wheel and get the code snippets that pertain to that entity’s focus on roof penetrations. Underwriters Laboratories ICC Please don’t hesitate to use it to your advantage. And of course if you have any feed back pro or con, let us have it. Take photo’s of your jobs using Quick Mount UL Products and submit them to us, we’ll put them up in our web gallery. Submit them to [email protected] Subject - Gallery Photo 2 5/16-18 x 1" SS Machine Bolt 5/16" ID Fender Washer 1.75" H Racking of Choice (Not Included)

0.563" EPDM Rubber 0.375" Counter Flashing 5/16" ID x 1 1/4” OD 1" Sealing Washer 6.250” 1 1/4" x 5 1/2" Aluminum Post 5.3” 10.625” 1.5“ 3 Aluminum 16.75“ Peel and Stick Flashing Flashing 12" x 11" 5/16”-18 x 2" TAP Bolts for OSB Substrate

Plywood Attachment Method: 5/16”-18 x 1" 4 -Lag Screws, 1/4" x 1 1/2" Grade 8 Bolt through Base Knock-out Holes Cast Aluminum Base Plate 5" x 3.5" x 0.5" TITLE: QMFTM Flat Tile Assembly updated text 05/18/10-kg COMMENTS FILE NAME QMFTM_EXP 5/16”-18 Toggles DATE 9/24/09 REVISION PROPERTY OF QUICK MOUNT PV * ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED DRAWN BY A.B.K. R

FLAT TILE “RAFTERLESS” MOUNTING INSTRUCTIONS 1 2 3

Tools required to install (see list on specifica- Remove Tile at location of Mount. Measure Use the Base Plate as a template to mark the tion page). up 6 5/8” to center of Mount. Mark paper, drilling of the top and bottom holes. Remove then measure 5 1/2” from exposed edge of Base Plate, drill 3/4” hole through deck. In- adjoining right tile to center of mount, and sert toggler bolts per Toggle Instructions mark paper. (see page 2).

4 5 6

Insert Machine Bolt under Base Plate in hex slot Carefully clean the building paper & press With wedge still in place on the leading edge so threads point upward. Place Base Plate the Peel and Stick firmly around Base and of tiles above, lift left side tile and set Alumi- over Toggles and secure with 2 ea 5/16” x 1 paper. Work from the center out removing num Flashing into place. 1/2” Machine Bolts into Toggles. any air pockets. (* below, ** page 1)

You are now ready for the rack of your 7 8 choice. Follow all of the directions of the rack manufacturer as well as the module manufacturer.

All Roofing manufacturers’ written instruc- tions must also be followed by anyone modifying a roof system. Please consult the roof manufacturers’ specs and instructions prior to touching the roof.

* Make sure the Peel and Stick is firmly ad- hered and that all air bubbles are pushed out. Insert Post through Flashing and secure to Slide on EPDM Counter Flashing. Base threads. Add Sealant at Post to Flash- ing joint. For Questions Call 925-687-6686 www.quickmountpv.com [email protected]

4 -kg 2010May18 Instructions QMFTM