Second Generation of Intrauterine Balloon Tamponade: New Perspective
Total Page:16
File Type:pdf, Size:1020Kb
COMMENTARY BMJ Innov: first published as 10.1136/bmjinnov-2019-000404 on 20 January 2020. Downloaded from Second generation of intrauterine balloon tamponade: new perspective Younes Bakri,1 Christopher B- Lynch,2 Souhail Alouini 3 1Obstetrics & Gynecology/ COMMENTARY and multiple square sutures,4 17 uterine- Gynecologic Oncology, Ayoub hypogastric artery ligation, hysterec- Medical Center, Amman, Jordan Every day in the year 2015, about 830 2Obstetrics and Gynaecological women died of childbirth and pregnancy tomy were reported. All other treatments Surgery, Milton Keynes complications. Almost all these deaths except embolisation,2 required an open University Hospital, NHS Foundation Oxford Deanery, occurred in low resource settings, and laparotomy surgery to control PPH. Oxford, UK most could have been prevented. The Tamponade devices’ complications of 3Obstetrics and Gynaecological primary causes of death were haemor- migration/expulsion, rupture/leakage, Surgery, Centre Hospitalier 1 Regional d’Orleans, Orleans, rhage, hypertension and sepsis. uterus perforation and infection were France The last two decades witnessed global reported. efforts, including Public Health, clinical, Pregnancy-related haemorrhage and Correspondence to academic, administrative and socioeco- sepsis (including unsafe abortion and Dr Souhail Alouini, Obstetrics and Gynaecology, Centre nomic, to save lives at birth, worldwide. molar pregnancy), are the leading causes Hospitalier Regional d’Orleans, In low- income and middle- income of maternal death in the low-resources Orleans 45032, France; alouini. countries, the risk of a woman dying of a regions worldwide. s@ orange. fr maternal-related cause during her lifetime A recent WHO 2016 report estimated Accepted 26 December 2019 is about 33 times higher, compared with that during the time period of 2010–2014, Published Online First a woman living in a developed country. there were 35 abortions per 1000 women 20 January 2020 The number of women dying of compli- (aged 15–44) worldwide. This translates cations during pregnancy and childbirth to over 56 million abortions per year. An has decreased by 43%, from an estimated earlier WHO 2008 report the following 532 000 deaths in the year 1990, down to estimates that 21.6 million women expe- 303 000 deaths in the year 2015, a testi- rience ‘unsafe abortion’ worldwide each monial that Global collaborative efforts year and most of them occurred in low- http://innovations.bmj.com/ ‘work’.1 income and middle-income countries. Progress was achieved in the manage- Death due to ‘unsafe abortion’ remains ment of maternal postpartum haem- close to 13% of all maternal deaths. orrhage (PPH) of vaginal birth and Types of currently available tamponade Caesarean section2–7; however, less prog- devices. ress was attained in case of pregnancy- The following balloon catheters were related bacterial sepsis, including designed for placement in the uterus for puerperal sepsis and postabortion sepsis, tamponade control of PPH, occurring 4 on October 1, 2021 by guest. Protected copyright. particularly unsafe abortion’s intrauterine after vaginal or Caesarean section birth : Bakri tamponade balloon catheter—the infection. Sepsis is one of the leading ► Bakri tamponade balloon catheter is the causes of maternal mortality, worldwide. first uterine tamponade balloon system Introduced in the year 1999, Bakri designed specifically for the treatment of 4 8–10 SOS Tamponade Balloon, was the obstetric haemorrhage.4 It consists of a first uterine tamponade balloon system silicone balloon (maximum recommended for the treatment of PPH.4 9 11 Multiple fill volume 500 mL), connected to a 24 other devices followed, including: French silicone catheter 54 cm in length. © Author(s) (or their condom catheters,12 BT- Cath,13 ESM- The collapsed balloon is inserted into the employer(s)) 2020. Re- use UBT (Every Second Matters - Uterine uterus when filled with fluid, the balloon permitted under CC BY- NC. No 14 15 adapts to the configuration of the uterine commercial re- use. See rights Balloon Tamponade), Ebb balloon and 16 cavity to tamponade uterine bleeding. and permissions. Published by Zhukovsky balloon. The central lumen of the catheter allows BMJ. Successful outcome (haemorrhage drainage and is designed to monitor To cite: Bakri Y, B- Lynch C, control) without the need for addi- ongoing bleeding above the level of the 2 Alouini S. BMJ Innov tional treatments such as embolisation, balloon. The device is intended for one- 2020;6:1–3. B- lynch compression,4 B- LUVS sutures time use. Bakri Y, et al. BMJ Innov 2020;6:1–3. doi:10.1136/bmjinnov-2019-000404 1 COMMENTARY BMJ Innov: first published as 10.1136/bmjinnov-2019-000404 on 20 January 2020. Downloaded from ► - BT Cath—the BT- Cath4 is a silicone balloon (maximum Table 1 Functions of the BakriOne recommended fill volume 500 mL) with an inverted pear shape to conform to the shape of the uterine cavity. Tamponade For haemorrhage control In contrast to the Bakri tamponade balloon catheter, Drainage Prevents concealment of bleeding BT- Cath’s end of the catheter is flush with the end of the Intrauterine infusion- instillation For uterotonics, antibiotics, balloon. One lumen of the dual lumen catheter is used tranexamic acid to infuse saline and expand the balloon, while the other Intra- uterine lavage For puerperal sepsis and septic lumen allows drainage of blood from the fundus. It is abortion intended for one- time use. Diagnostic functions 4 ► ebb tamponade system —The ebb tamponade system is (A) Collecting tissues/fluids from the uterine cavity, for lab function tests, a dual polyurethane balloon device containing an upper to guide antibiotic therapy in septic abortion and puerperal sepsis. uterine balloon (maximum recommended fill volume (B) ‘Tamponade test’3 4 7 to evaluate effectiveness of internal compression 750 mL) and a lower vaginal balloon (maximum recom- treatment. mended fill volume 300 mL). A central drain allows for monitoring of possible ongoing or recurrent haem- orrhage from above the uterine balloon. The device is intended for one- time use. Other devices that have been shaft, allows for better visualisation of flow and helps used for uterine tamponade, but are not intended for this in care and maintenance. Separate medication port for purpose, include the following: intrauterine topical treatments, for example, utero- – Sengstaken- Blakemore tube (used for treatment of tonics, antibiotics, tranexamic acid as the efficiency bleeding oesophageal varices). of these treatment were reported in other studies.18–20 – Single or multiple Foley catheters (used for bladder Radiopaque stripe for X- ray placement verification. drainage). – Rusch urological balloon (used for stretching the Drainage obstruction will be easy to identify with the bladder). translucent silicone or PVC tubing. – Condom catheter (a condom is placed over the end The PVC ‘Carus- Curve’ (size 48 Fr. tubing option), of a Foley- type catheter, the base of the condom is conforms to the anatomy of the birth canal and helps ligated to the catheter to prevent leakage and then preventing expulsion of the balloon, a problem which the condom is filled with up to 500 mL fluid via the occurs in about 10% of currently available balloons. catheter). The BakriOne balloon is hereby proposed to treat – Size 8 surgical glove tied to an intravenous infusion the pregnancy- related haemorrhage and intrauterine or other catheter, and then filled with up to 500 mL fluid. infections/complications as deemed appropriate. Rusch balloons, surgical glove and condom catheters Functions of the BakriOne are included in table 1. are made of latex rubber; the other devices are made The versatility of the BakriOne system’s technology extends its benefits and applications to all global of silicone or polyurethane. http://innovations.bmj.com/ geographic regions, including, the lower resources regions. It is designed as a safe, simple, cost- effective INTRAUTERINE BALLOON: SECOND GENERATION and easy- to- use technology. User- friendly—does not BakriOne balloon is a new second generation tamponade require assembly. Readily available to apply in emer- balloon design system, for the treatment of pregnancy- gency situations, even in remote rural locations. related uterine haemorrhage and infection, is a novel technology design system which takes into consider- Contributors YB designed the device, wrote and approved the ation all possible variations in the clinical presentation article; CB- L participated to the content and approved the article; of pregnancy- related uterine haemorrhage and/or sepsis. SA designed, particpated to the content, wrote and approved the article. on October 1, 2021 by guest. Protected copyright. It brings a bold, off the beaten path treatment approach, Funding The authors have not declared a specific grant for this applicable to all pregnancy trimesters and covers normal research from any funding agency in the public, commercial or or abnormal pregnancies including, abortion, miscar- not- for- profit sectors. riage and hydatidiform mole pregnancies. Competing interests None declared Trademark Application for: ‘BakriOne.’ Patient consent for publication Not required. US Trademark Application No: 87937508. Provenance and peer review Not commissioned; externally peer Our Matter Docket No: 00510.003- TM- USW reviewed. (BakriOne). Open access This is an open access article distributed in accordance Status: allowed. with the Creative Commons Attribution Non Commercial (CC BY- The