WAREHOUSING 05.14 EB 6936 ACTIVE ENTERPRISE 6750

ACTIVE DATA WAREHOUSING PLATFORM FOR TERADATA SOLUTIONS

In today’s fast-paced, ever-changing competitive envi- ronment, your data warehouse must provide higher performance, availability, and scalability to support your business’s vastly increased tactical and analytical work- loads. As a member of the Teradata® family of workload specific platforms the Teradata Active Enterprise Data Warehouse (EDW) 6750 meets the widest range of oper- ational and strategic intelligence needs as the highest performing, most dependable, and most cost effective platform for a Teradata solution.

The Teradata Active EDW platform and Teradata together compose a totally integrated solution optimized for the operational and strategic analysis needs of the Teradata Unified ™ . As a proven frame- work, the Unified Data Architecture™ is a collection of services, platforms, applications, and tools that makes optimal use of available technologies to enable organiza- tions to gain optimal value from all their data. The Active EDW 6750 is the robust platform for the integrated data warehouse element in the Unified Data Architecture™ that serves to operationalize this data value throughout your organization. The result? You focus on your business and not on managing technology, enabling you to make smarter decisions on any data at any time, faster and with maximum ROI.

To support your data warehousing initiatives, the Teradata Active EDW 6750 platform is purpose built to run the Teradata Database to its fullest capabilities making. With the Teradata Active EDW, you can com- including the industry leading Teradata Virtual Storage bine both these strategic and operational workloads in a and Teradata Active System Management. The massively single data warehouse. The key attributes of the Teradata parallel processing (MPP) architecture of the platform is Active EDW platform are: the perfect match to the parallel, shared nothing archi- tecture of the Teradata Database. HIGH-PERFORMANCE TECHNOLOGY This Teradata Active EDW platform delivers real-time With modular design and architecture, the Teradata Active intelligence to place vital data into the hands of front-line EDW platform is implemented with best in breed system decision makers, while extending traditional data ware- elements that are independently evolved without impact house functionality into the realm of tactical decision to the rest of the system. An example of this evolution is

1 DATA WAREHOUSING 05.14 EB 6936

Teradata Database’s ability to leverage the most current industry-leading Intel® technology to achieve high-perfor- mance database nodes. The Active EDW 6750 Ethernet Switch features the 12 Core Intel Xeon® Processor and the plat- form’s parallel architecture fully leverages both the Intel Multi-Core and Hyper-Threading processor technologies Disk Array to gain maximum processor and system performance. 96 Drives SSD & HDD Another example of a key technology evolution delivered with the Active EDW 6750 is the use of hybrid storage that combines Solid State Drive (SSD) and Hard Disk Drive Disk Array (HDD) technologies for performance optimization of your 96 Drives data. With Teradata’s hybrid storage, the frequently used SSD & HDD hot data are stored on very high-performance SSD devices while the less frequently used cold data are placed on the HSN traditional performance HDD devices. Unique to Teradata Node data warehouses, the placement and migration of data based on data temperature is fully automatic with the 36-port BYNET SW Teradata Virtual Storage feature. Cabinet VMS In operation, the Teradata parallel architecture uniquely 36-port BYNET SW takes full advantage of the speed of SSD storage. In fact, an SSD device is up to 27-times faster than enterprise Node HDD devices for Teradata workloads. While SSD offers a basic performance enhancement to a Teradata system, Disk Array SSD’s real magic is that it enables the full data warehouse 96 Drives power of a Teradata node to be applied to a far smaller SSD & HDD size of than with an HDD-only storage approach. The result is a significant boost in performance per capacity for a Teradata solution. Disk Array 96 Drives The bottom line is that higher query throughput along SSD & HDD with faster, more consistent query response times provide business value by allowing more real-time users, faster Ethernet Switch response to events, deeper and more complex analytics, and broader application of your active data warehouse.

SCALABILITY Figure 1. Teradata Active EDW 6750 Platform Cabinet Components. Unmatched in its scalability, a Teradata system based on the Teradata Active EDW platform accommodates future business growth by expanding incrementally from one to 2,048 nodes. It also accommodates user data space from AVAILABILITY eight terabytes to 61 petabytes of uncompressed user The Teradata Active EDW platform achieves availability data. Featuring MPP architecture, the platform supports through Teradata’s unique clique architecture in which scalable growth not only in data capacity but in all dimen- one or more nodes and a hot standby node are con- sions including performance, users, and applications. nected to common storage. This clique approach allows Teradata Database to seamlessly failover workloads The Teradata BYNET® system interconnect for high- between the active and hot standby nodes in a clique if speed, fault tolerant messaging between nodes is a key a node does fail. Minimizing the impact of component ingredient to achieving scalability. The BYNET is based or module failures, the platform also contains redundant on a robust, powerful protocol with innovative database hardware components, so if a failure does occur, it won’t messaging features that optimize the use of a dual affect Teradata Database operation or the end-user InfiniBand fabric for the Teradata MPP architecture.

2 DATA WAREHOUSING 05.14 EB 6936

experience. Many of the hardware components are Teradata BYNET InfiniBand Switches – Supports the hot-swappable, allowing service repair without affecting high-performance BYNET system interconnect with high system availability. availability, fault tolerant, dual networks that ensure highly scalable, error-free MPP communication. These MANAGEABILITY AND EASE OF USE switches, housed in the system cabinet, are sized for systems up to 18 nodes. For larger sized systems, a The platform features simplified platform administration, separate BYNET switch cabinet is used to scale out the control, and monitoring with the single operational BYNET-based InfiniBand fabric to the required number provided by the Teradata Server Management Web of nodes. Services. Channel node – A dedicated Teradata node that supports The industry-leading, integrated systems management Teradata Database’s unique capability for mainframe infrastructure monitors and controls the system, performs connectivity. Also, the Extended Channel Server enables routine events, such as orderly start up and shut down, connection to a remotely located mainframe. and prevents harm from a disruptive failure, such as a power outage or extreme heat. Combined with Teradata Teradata Managed Server – Applies enterprise-level Viewpoint, which provides an intuitive and easy-to-use Teradata system management capabilities to a commodity interface for managing and monitoring one or more server for applications that support Teradata Database. Teradata systems, the platform enables users to have A base model of the server can be configured to meet continuous access to the status of their business results. your needs and supports the Linux® operating system. Pre-configured models are available for specific Teradata GROWTH WITH INVESTMENT PROTECTION tools and applications, such as Teradata Unity, Data The Teradata Active EDW platform and the Teradata Mover, Multi-System Manager and data loading. Multiple Database have the capability called coexistence that Teradata Managed Servers can be supported in the supports multiple platform generations within a single cabinet and in a separate Platform Framework Cabinet. system while gaining full performance from each gen- eration. By enabling expansion through coexistence, Virtual Management Server (VMS) – Based on the you can grow your system to include the latest platform Teradata Managed Servers and virtualization technology, technology, while reaping a return on your initial tech- this server virtualizes multiple key system functions into nology investment and leveraging the price/performance a single physical server. These functions include the curve as it evolves. Teradata Viewpoint Appliance, the cabinet management functions, and the Teradata Customer Services Worksta- The Active EDW 6750 coexists with the previous genera- tion for remote access to the system. The VMS saves tions of hybrid storage platform along with support for valuable cabinet rack space by eliminating the need for coexistence with future generations of the Active EDW separate physical servers for each of these functions. platforms. Platform Framework Cabinet (PFC) – Provides a flexible FLEXIBLE PLATFORM OPTIONS approach to the packaging and management of all the platform elements described above that are not Teradata The Teradata Active EDW supports a variety of processing node or storage related. In addition to these elements, and storage elements integrated into the system cabinets such as Teradata Managed Server and BYNET Switches, for the flexibility to meet customer needs. These include: the Backup Archive Restore (BAR) backup devices for smaller sized systems are supported as space permits. Teradata node – The basic processing element for the Teradata Database. PLATFORM SUSTAINABILITY Hot standby node – A redundant Teradata node added The Teradata Active EDW platform’s performance and to a clique to provide full performance continuity during scalability enable you to save significant energy and floor node failure. space while achieving the same data warehouse work as done by previous systems. The enhanced processing Data storage arrays – Multiple storage arrays that pro- power of the nodes in the Active EDW 6750 and vide both the RAID controllers and data storage drives. increased cabinet node count combine to provide up to The storage drives can be either SSD or HDD drive types. twice the performance capability in a single cabinet

3 DATA WAREHOUSING 05.14 EB 6936

THE TERADATA ACTIVE EDW PLATFORM The Teradata Active EDW 6750 is available in one basic model. To meet your needs, choose the amount of frequently used hot data needed for each node, as determined by the amount of SSD storage, and the amount of less frequently used warm/cold data as determined by the number and capacity of HDD storage.

FEATURES AND CAPABILITIES 6750H Storage Architecture Hybrid Storage Intel Xeon Processors 12-Core 2.7GHz Memory/Node 512GB TPerf/Node (Teradata’s performance ) 240 Cliques (redundancy group)/cabinet One Max active nodes/cabinet (and clique) 3 Coexistence Three generations Teradata BYNET V5 BYNET Software On InfiniBand SSD 2.5” 400GB HDD 2.5” 10K RPM: 300-, 450-, 600GB User Data Space per Node (no compression) 8 – 30TB Teradata Database Version 14.0 and higher

Figure 2. Teradata Active EDW 6750 features and capabilities.

compared to previous generations of Active EDW. This Active EDW is the solid foundation you need to drive dramatically reduces the floor space and energy for the real value from your data to maximize the return on same performance and data space. Also, this Teradata your investment. platform’s unique coexistence capability lengthens the useful life of Teradata systems resulting in less carbon Each platform is integrated according to the configura- and electronic waste. tion that best meets your needs and is pre-tested, so it’s ready to run right after delivery. You can begin loading PURPOSE-BUILT PLATFORM data and running queries shortly after initial delivery— EXCELLENCE and quickly begin getting business value. The Teradata platform provides unmatched performance The Teradata Active EDW platform can adapt and grow for all your strategic and operational analytics needs, along with your business. Backed by award-winning eliminates risk, and allows you to focus on driving the professional services, support, and Teradata Corporation’s highest return on your data warehousing investments— demonstrated data warehousing expertise, the Teradata today and in the future.

4 DATA WAREHOUSING 05.14 EB 6936

TERADATA ACTIVE ENTERPRISE DATA WAREHOUSE 6750 DESCRIPTION

TERADATA NODES – 1Gb Copper – Quad Port – Full disk encryption on HDD Adapter drives for secure data if drive Processors – 1Gb Fiber (Optical) – lost or stolen • Intel Xeon Processors E5-2697 Dual Port Adapter • NetApp E5500 Arrays V2 Series, 12 Cores – 10Gb Copper and Fiber – – Up to 96 drives (SSD and • Clock speed: 2.7GHz with maxi- Dual Port Adapters HDD) per array mum Turbo Boost to 3.5GHz Operating System • Up to 30MB Level 2 Cache per – Up to four arrays per cabinet ® processor • SUSE Linux & SLES 11 – High availability with dual • Intel Hyper-Threading Tech- Teradata BYNET V5 MPP redundant RAID 1 controllers nology with 2 threads per Core Interconnect – Full protection • Intel Quick Path Interconnect at • Enables linear scalability up to with T10DIF end-to-end data up to 8 Giga-transactions per 2048 nodes maximum integrity second for I/O • Fault tolerant interconnect via Teradata Database Memory dual networks • Integrated and certified with • Up to 512GB (standard) using • QDR InfiniBand interconnect for Teradata Database physical layer DDR3 fully-buffered DIMMS - Release V14.0, V14.10, V15.0 with ECC – Up to 10GB per second per node bandwidth on dual and future releases • Memory controller built into redundant networks • 6750H requires Teradata each Xeon processor • Up to 100M link cable length Virtual Storage feature to Node Internal Storage Devices for data center flexibility (other provide automatic temperature- lengths available) based and • Integrated RAID controller with management in hybrid storage • InfiniBand adapters on PCIe SAS backplane (SSD and HDD) • Eight media bays per node Gen 3 for optimal interconnect – Up to four hot-swappable performance System Cabinet SAS hard drives (plus three • BYNET V5 Switch Cabinets • High-density cabinet enables 900GB drives as standard for support system sizes over complete Teradata clique (nodes operating system and dump) 18 nodes with cascadable and storage) in one cabinet InfiniBand switches of 108 and – One CD/DVD-ROM drive • One to three Teradata nodes 324 ports in separate cabinet plus Hot Standby node Connectivity per Node models • Five storage arrays per cabinet • Seven PCI slots Data Storage each with SSD and/or HDD – Four full-height PCIe Gen 3 • Storage Devices devices – Three half-height PCIe Gen 3 – 400GB SSD, SAS Enterprise • Dual, 36-port BYNET V5 • Storage Connectivity Flash drives switches support up to 18-node system size – 6Gb Quad and Dual SAS – 300GB, 450GB and 600GB Adapters HDD, SAS interface, 10K RPM, • Cabinet management server • Customer Ethernet Network enterprise-class drives and Ethernet network switches Connectivity – SSD provides ECC data • Dual AC distribution with raised – Four on-board 1Gb Ethernet protection and supports floor or overhead AC cable egress connections (two for Server robust, five year write wear Management) out protection

Continued

5 DATA WAREHOUSING 05.14 EB 6936

Platform Framework Cabinet OPERATING SPECIFICATIONS Availability Management • Teradata Managed Servers for • Height: 80.5 in. (204.5 cm) Services related applications such as Load, • Width: 24 in. (61.4 cm) • Proactive, holistic approach Unity, Data Mover, and SAS • Depth: 47 in. (119.4 cm); for protecting a system from • Virtual Managed Server 49 in. (124.4 cm) with doors risk events that can reduce or combines Teradata Viewpoint, degrade availability. • Weight: 1,734 lbs. (786 kg) cabinet management, and fully loaded Premier Warehouse Support services workstation functions • Operating Temperature: • Delivers a single source service • Teradata Channel Nodes for 59°F to 89.6°F (15°C to 32ºC) to maximize value and availability Mainframe Connectivity: FICON of your solution. and ESCON • Voltage Range: North American: 200-240VAC, • Teradata Backup Archive • Flexible support options that International: 220-240/380- Restore (BAR) allow you to select the coverage 415VAC and response times you need. – Tape and disk storage • Frequency: 50/60Hz products (see External BAR • Integrated, proactive tools, such below) • Current: as Teradata Vital Infrastructure North American: 30A 4-cord ™ High Availability Hardware and Teradata ServiceConnect or 60A 2-cord, remote connectivity. Features International: 32A 2-cord • Multiple AC inputs enable • Power: 7,100 Watts Max Teradata Vital Infrastructure power sourcing from two grids • Dual AC: Standard; overhead • Built-in support software for maximum uptime. power routing supported available on each Teradata • Hot pluggable/replaceable • Compliant with U.S. and Active EDW platform. components include power International Safety and • Regularly collects system supplies, disks, and cabinet fans. Emissions Standards asset data. • Fault resilient fan modules, • RoHS compliant; WEEE • Fault event data are recorded; redundant power supplies, fault Services available automatic incident reports tolerant BYNET Interconnect. are created. External Backup Archive SUPPORT SERVICES • Alert notifications are sent and Recovery (BAR) tracked (Call Home capability). Global • Teradata integrated products Implementation Services • Regional service centers and and solutions in-country local language • Staging – Quantum Tape libraries support • Installation – EMC Data Domain Disk • 24/7 support • Software Implementation Backup – Storage management • Experienced data warehousing Operational Services service associates with Symantec NetBackup • Critical System Management (BakBone NetVault or IBM Warranty Support • Data Migration Tivoli are alternatives) • One-year remote and on-site • Operational Mentoring hardware support, operating system problem resolution • 24-hour incident reporting

10000 Innovation Drive Dayton, OH 45342 teradata.com

Unified Data Architecture and ServiceConnect are trademarks and BYNET, Teradata and the Teradata logo are registered trademarks of Teradata Corporation and/or its affiliates in the U.S. or worldwide. Intel, the Intel logo, Intel Inside, Xeon, the Xeon logo, and Xeon Inside are trademarks of Intel Corporation in the U.S. and/or other countries. Microsoft 6 and Windows are registered trademarks of Microsoft Corporation. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries. Novell and SUSE are registered trademarks of Novell, Inc. Teradata continually improves products as new technologies and components become available. Teradata, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed in all parts of the world. Consult your Teradata representative or Teradata.com for more information. Copyright © 2014 by Teradata Corporation All Rights Reserved. Produced in U.S.A.