Opendac® I/O System

Total Page:16

File Type:pdf, Size:1020Kb

Opendac® I/O System OpenDAC® I/O System OPENDAC® I/O SYSTEM OpenDAC ® I/O System Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Contents: OpenDACOpenDac® I/O System OPENDAC® I/O SYSTEM Low Cost Remote I/O System FEATURES • Compatible with Present Systems • Communicates within third party hardware and software • Ethernet Version Page Network Interfaces OpenDAC® for Ethernet .............................................................................................. 2 OpenDAC® for Modbus .............................................................................................. 4 OpenLT (Optomux) ..................................................................................................... 6 OpenDAC® for Profibus ............................................................................................. 8 Racks 16 Channel ............................................................................................................... 10 OpenDAC ® I/O System OpenDAC® I/O System The OpenDAC® family is a compact, low cost and flexible I/O system that is used for remote data requisition and control. Each network interface is capable of interfacing with one or two OpenDAC® I/O racks that allow a maximum of 32 channels of OpenLine® I/O modules. With the exception of the OpenLT™, they do not have the capability of running embedded control programs (ECPS). If this is a requirement, please review the OpenLine® Control System. OpenDAC® I/O racks are not compatible with the OpenLine® Controllers. OpenDAC Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com 1 OpenDAC® I/O System NETWORK INTERFACES OpenDAC® for Ethernet FEATURES • Use Ethernet to Control/Monitor up to 32 Analog and/or Digital I/O Channels using OpenLine® I/O Modules • Network Multiple OpenDACs® • 10Base-T and 100Base-TX Support • Extremely Fast Response Times over Network • Support Modbus/TCP Protocol and HTTP • Use Web Browser for Configuration, Monitoring and Control of I/O modules • Diagnostic LEDs • CE Certified ETHERNET UNIT ON OPENDAC® SYSTEM • DIN Rail Mounting • Modbus TCP APPLICATIONS GENERAL DESCRIPTION The OpenDAC® for Ethernet network inter- Each OpenDAC® incorporates a communication Stand Alone Control face is a remote slave that responds to watchdog timer that monitors communication Modbus/TCP commands that it receives over from the Modbus/TCP master. When the Local Control & I/O the network. The status and configuration of watchdog is enabled and the slave does not up to 32 OpenLine® analog or digital I/O chan- receive a valid Modbus/TCP message within a Remote I/O nels is stored and constantly refreshed. specified time, the OpenDAC® will set all output OpenDAC® for Ethernet is self-configuring. On modules to the stored fault-state values. Should Distributed I/O power up, the controller will identify the types a valid message be received, the timer is reset of I/O modules present. The unit will then con- and communication resumes. All configuration SCADA tinuously scan and update the digital and ana- parameters are displayed and modified using a log modules. Digital input channels can be web browser. The configuration parameters RTU setup for latching operation. The OpenDAC® are password protected to provide security OpenDAC for Ethernet supports the OpenLine® Smart against unauthorized access. Module Protocol (SMP) that allows field cali- bration and parameter setup of I/O modules. ® I/O System ANALOG & DIGITAL I/O ® Each OpenDAC or third party device on the MODULES network is assigned a unique IP address. There OpenDAC® for Ethernet connects directly to are three methods of assigning the internet one or two 16 channel racks. Any combination protocol address -BOOTP, DHCP, and a static of analog and digital I/O modules may be used. method. The controller is shipped with the default On power up, the OpenDAC® scans and stores IP address of 128.0.0.1. The IP address can be the I/O configuration and makes the information changed using a web browser. The web browser available to the master. can also be used to select BOOTP or DHCP to assign the IP address. Communication data In addition to simple On/Off instructions, the rates are either 10 Mbps or 100 Mbps. OpenDAC® allows you to: OpenDAC® automatically detects whether it is • Read linearized thermocouple and RTD connected to a 10Base-T or 100Base-TX temperature values network, eliminating switch settings and • Detect rising or falling edges simplifying set up. Network and controller status • Latch momentary input events can be monitored by status LEDs. • Set the level of analog outputs OpenDAC 2 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com OpenDAC® I/O System DIMENSIONS In inches (and millimeters) 4.1(104,26) 3.9 (99,56) OpenDAC for Ethernet DEFAULT CONFIG POWER RESET STAT DIN RAIL LATCH LINK 2.6 (65.48) 2.3 (57.17) PIN 1 TO CENTERLINE OF DIN RAIL CHANNEL SPECIFICATIONS ORDERING INFORMATION Supply Voltage: 4.80 to 5.25 Vdc Supply Current (less modules): 1.0 amp Part Number Description max. Ethernet Network Interface Operating Temperature: -40 to 85°C Humidity: 5-95% non-condensing 72-ETH-T000 Analog/Digital OpenDAC® for Ethernet Housing Material: ABS/Polycarbonate blend Ethernet User’s Manual and Software CPU: Net+ARM 40 Connections: 72-UM-OETH OpenDAC® for Ethernet user’s manual Network: RJ-45 72-UM-ETH OpenLine® for Ethernet user’s manual Passive Rack: 48-Pin Euro DIN (male) 72-UOL OpenLine®/OpenDAC® configuration and product data Range of Network (without repeaters): 72-UME-DLL32 Ethernet/Modbus DLL for Windows 95/98/NT 100 meters with CAT 5 UTP Compatible Components OpenDAC OpenDAC® I/O Racks Analog OpenLine® I/O Modules Digital OpenLine® I/O Modules Power Supply ® I/O System Available from your local authorized Grayhill Distributor. For prices and discounts, contact your local sales office, an authorized Distributor or Grayhill. OpenDAC Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com 3 OpenDAC® I/O System NETWORK INTERFACES OpenDAC® for Modbus FEATURES • Each Unit Controls/Monitors up to 32 Analog and/or Digital I/O using OpenLine® Modules • Network up to 247 OpenDACs® per Host PC, Each Separated by as much as 4,000 Feet • Communicate Over RS-422/485 at Speeds from 9600 Baud to 56.7 KB • 100% Modbus ASCII or Modbus RTU Compatible • CE Certified • DIN Rail or Panel Mount MODBUS UNIT ON OPENDAC® SYSTEM APPLICATIONS GENERAL DESCRIPTION OpenDAC® for Modbus is an inexpensive, format to code the command and the response Stand Alone Control flexible interface to 32 analog or digital messages. Application programs running on OpenLine® I/O. As one of 247 slave devices on the host computer issue commands and then Local Control & I/O a Modbus network, OpenDAC® for Modbus await responses from the OpenDAC®. The constantly scans and stores the current status communications speed is switch selectable Remote I/O of each I/O. Upon command from the host between 9600 and 56700 baud. The entire device, the controller will change the status of network can span 4000 feet. Distributed I/O an output or return the value of an input. The slave address is switch selectable. Diagnostic FAULT TOLERANCE SCADA LEDs provide troubleshooting assistance. Each OpenDAC® for Modbus has an internal communications watchdog timer to minimize OpenDAC RTU ANALOG & DIGITAL I/O the impact of a broken Modbus link between the OpenDAC® for Modbus connects directly to two controller and the master device. If activated, 16 channel racks. Any combination of analog the timer must be reset by an incoming message ® within the prescribed period of time. If not, the I/O System and digital I/O modules may be used. On power up, the OpenDAC® scans and stores the I/O controller will force it’s outputs into a default configuration and makes the information state. available to the master for query. SOFTWARE In addition to simple On/Off instructions, Modbus Software drivers are available which simplify commands allow you to: the task of interfacing host programs written in • Read linearized thermocouple and RTD Visual Basic or C to the Modbus network. Sample temperature values programs, set-up and debug utilities are included • Count pulses at frequencies up to 1000Hz on the disk with the drivers. Interface drivers for • Detect rising or falling edges most third party software packages are available • Latch momentary input events through their distributors. Our DLL will assist • Set the level of analog outputs you in building custom Man-Machine Interfaces using Visual Basic, Visual C/C++, or Borland COMMUNICATIONS compilers running on Windows 95, 98 or NT. The host computer and OpenDAC® for Modbus communicate serially over one or two pair of twisted wires per RS-422/485 in a multi-drop configuration. They use Modbus ASCII or RTU OpenDAC 4 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com OpenDAC® I/O System DIMENSIONS In inches (and millimeters) 4.1(104.26) 1.1 3.9 (99.56) (28.22) DIN RAIL LATCH 1.0 (25.86) 3.0 (75.69) 2.6 (65.48) 2.3 (57.17) PIN 1 TO CENTERLINE OF DIN RAIL CHANNEL SPECIFICATIONS ORDERING INFORMATION Power Supply: 4.75 to 5.25 Vdc Supply Current (less modules): 1 amp @ 5 Part Number Description Vdc max. OpenDAC® Network Interface Operating Temperature: 0 to 60°C Humidity: 95% non-condensing 72-MOD-4000 Analog/Digital OpenDAC® for Modbus Microprocessor: V25 @ 10 MHz Housing Material: ABS/Polycarbonate blend OpenDAC® User’s Manual and Software Connections: ® RS-422/485: 5 position depluggable connector 72-UM-OMOD OpenDAC for Modbus user’s manual Passive Rack: 48-pin Euro DIN (male) 72-UME-DLL32 Ethernet/Modbus DLL for Windows 95/98/NT Serial Data: 72-UOL OpenLine® configuration and product data Format: 10 Bit ASCII: 1 Start, 1 Stop, 8 Data OpenDAC Integrity: Message Checksum Compatible Components Range of Network: Compliant with EIA/TIA OpenDAC® I/O Racks RS485-A (1 standard load per controller).
Recommended publications
  • Parock1 Flyer
    OPTO22 PAC Rx/Sx controllers Overview: The Opto 22 Ethernet driver provides an easy and reliable way to connect Opto 22 Controllers to your OPC client applications, including HMI, SCADA, Historian, MES, ERP, and countless custom applications. Properties Screen Shot Features - Supports all OPTO 22 PACs or any other device which uses OPTO22’s native protocol CONT over Ethernet TCP/IP - high-speed Ascii based communication - Different from Optomux and OptoMMP - Same native protocol as used by Opto Sim & OPTO PAC Display. - Index of table support - Pointer towards tag support - Performance – 2.2GHz Dual Core - 10 words: 15 ms - Data Types supported o I32 o I64 o Float o Timer o String For More Info: Overview of Parijat Drivers: Click here Additional supporting Info about Parijat Drivers: Click here Complete Related Driver options: Click here Copyright © parijat controlware, inc. Any other legal rights belong to their respective owners. Any useage here is only for reference purpose contents subject to change without notice. 7/25/16 9603 Neuens Rd, Houston Tx 77080 . tel: (713) 935-0900 . fax: (713) 935-9565 . http://www.parijat.com . Email: [email protected] PCI PC-resident Drivers: General Information General Info about PCI driver Products PCI sells & supports the world’s largest range of communications drivers for Industrial automation, PLC, process control industry applications for Microsoft, Google, Apple, Linux products & ASP.NET core for web portal products. This document outlines various common features & knowledge base to help you make a decision. Welcome to the world of PCI, your exclusive and most mature, experienced (since 1989) source of help in Industrial data acquisition, control, HMI, SCADA and MIS, MRP, ERP or Browser based Internet applications based on non-proprietary open architecture.
    [Show full text]
  • Connect-And-Protect: Building a Trust-Based Internet of Things for Business-Critical Applications Table of Contents
    WHITE PAPER CONNECT-AND-PROTECT: BUILDING A TRUST-BASED INTERNET OF THINGS FOR BUSINESS-CRITICAL APPLICATIONS TABLE OF CONTENTS THE INTERNET OF WHATEVER 3 LET’S GET PHYSICAL 8 TALK THE TALK 11 PROTECTED INTEREST 14 PICTURE ME ROLLING 23 DATA: THE NEW BACON 25 CONCLUSION 29 SOURCES 29 ABOUT ARUBA NETWORKS, INC. 30 WHITE PAPER CONNECT-AND-PROTECT: INTERNET OF THINGS THE INTERNET OF WHATEVER Today it’s almost impossible to read a technical journal, sometimes a daily paper, without some reference to the Internet of Things (IoT). The term IoT is now bandied about in so many different contexts that its meaning, and the power of the insights it represents, are often lost in the noise. Enabling a device to communicate with the outside world isn’t by itself very interesting. The value of the IoT comes from applications that can make meaning of what securely connected devices have to say – directly and/or inferentially in combination with other devices – and then act on them. Combining sensors and device with analytics can reveal untapped operational efficiencies, create end-to-end process feedback loops, and help streamline and optimize processes. Action can take many forms, from more efficiently managing a building or factory, controlling energy grids, or managing traffic patterns across a city. IoT has the potential to facilitate beneficial decision making that no one device could spur on its own. But that potential can only be realized if the integrity of the information collected from the devices is beyond reproach. Put another way, regardless of how data gathered from IoT are used, they’re only of value if they come from trusted sources and the integrity of the data is assured.
    [Show full text]
  • Pac Control User's Guide
    PAC CONTROL USER’S GUIDE Form 1700-101124—November 2010 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080 Fax: 951-695-3017 Email: [email protected] Web: support.opto22.com PAC Control User’s Guide Form 1700-101124—November 2010 Copyright © 2010 Opto 22. All rights reserved. Printed in the United States of America. The information in this manual has been checked carefully and is believed to be accurate; however, Opto 22 assumes no responsibility for possible inaccuracies or omissions. Specifications are subject to change without notice. Opto 22 warrants all of its products to be free from defects in material or workmanship for 30 months from the manufacturing date code. This warranty is limited to the original cost of the unit only and does not cover installation, labor, or any other contingent costs. Opto 22 I/O modules and solid-state relays with date codes of 1/96 or later are guaranteed for life. This lifetime warranty excludes reed relay, SNAP serial communication modules, SNAP PID modules, and modules that contain mechanical contacts or switches. Opto 22 does not warrant any product, components, or parts not manufactured by Opto 22; for these items, the warranty from the original manufacturer applies. These products include, but are not limited to, OptoTerminal-G70, OptoTerminal-G75, and Sony Ericsson GT-48; see the product data sheet for specific warranty information.
    [Show full text]
  • Opto 22’S SNAP Control System Is a Versatile SNAP Digital Modules Switch Or Sense Either AC Or DC Combination of Hardware and Software to Support Signals
    SNAP I/O Control System Product Guide page 1/9 Form 788-001113 Opto 22’s SNAP Control System is a versatile SNAP digital modules switch or sense either AC or DC combination of hardware and software to support signals. Each module includes four channels and provides a wide variety of business applications. The system 4,000 volts of optical isolation from the field side to the consists of high-density digital, analog, and special- logic side. purpose I/O modules, compact industrial controllers, SNAP analog modules provide two or four channels. high-performance processor brains, and a series of They are factory calibrated and software configurable, mounting racks. Coupled with Opto 22’s powerful handling a wide variety of signal levels. FactoryFloor industrial automation software, SNAP offers SNAP special-purpose modules provide specific unparalleled flexibility and power for your control, functionality. Using serial modules, for example, you can monitoring, and data acquisition needs. communicate with serial devices such as chart recorders and barcode readers. Data-logging modules provide data storage SNAP I/O MODULES capacity, so that data from other modules on the same rack can SNAP analog and digital input and output modules be stored for later retrieval. PID modules monitor input signals provide compact, high-density I/O, with top-mounted and adjust output signals to control a proportional integral connectors for easy field wiring. derivative (PID) loop, performing all PID calculations in the module. SNAP I/O Modules, Rack, and SNAP Ethernet Brain SNAP I/O Control System Product Guide page 2/9 Form 788-001113 SNAP BRAINS SNAP RACKS SNAP brains are high-performance, intelligent SNAP racks come in four sizes to accommodate a maximum processors designed to meet your distributed control needs.
    [Show full text]
  • LONWORKS for Audio Computer Control Network Applications
    LONWORKS® for Audio Computer Control Network Applications January 1995 Executive Summary LONWORKS is a control network technology developed by Echelon for monitoring and controlling electrical devices of all kinds. LONWORKS meets the criteria specified by the audio industry for a computer control network, and is ideal for amplifier and equalizer control, automatic crossover control, sequential load control, equipment fault monitoring, set-top box automation, and home theater control. Neuron Chips embedded with the LONWORKS protocol have been produced by both Motorola and Toshiba since 1992, and hundreds of thousands of chips have been sold worldwide. Neuron Chips can communicate with one another, allowing data and decisions to be shared between equipment manufactured by different companies. Transceivers, routers, gateways, development tools, and programming and diagnostic tools are available off-the-shelf. Instead of developing control network technology, customers can use LONWORKS technology to build better, more intelligent, less expensive audio products. Introduction A control network is a system of sensors, actuators, displays, and logging devices (referred to as "nodes") that are linked together to monitor and control electrical devices. Supervisory functions are typically handled automatically and require no manual intervention except to respond to faults that the system cannot itself correct. In audio applications, a control network may monitor equipment fault conditions, adjust gain and crossover settings, monitor MIDI inputs,
    [Show full text]
  • Communications Drivers Pcvue 12
    Your Independent Global SCADA Provider Technical Solution Communications drivers PcVue 12 INTERFACE DRIVER VERSION S Serial port Native - Integrated in PcVue E Ethernet port Act - Activated on order Mb Manufacturer board Mo Molex O OPC Server H Hilscher adapter N/S Not Significant Manufacturer Protocol/Equipment Interface Requirement Version ABB SPA-BUS S Native ALSTOM ESP GEM 80 S Native ALSTOM ESP Gemlan-T TCP/IP E Native ALSTOM Ethernet SRTP Mo PCU2000ETH Ethernet SRTP for C80-75 & C80- ALSTOM O SW1000ETH 35 Ethernet SRTP for C80-75 & C80- ALSTOM E Native 35 Time stamped PCI1000/2000/4000 ALSTOM Nbus ASCII / RTU Mo PCU1000 PCI1000/2000/4000 ALSTOM SNP-X Mo PCU1000 ALSTOM SNP-X for C80-75 & C80-35 O SW1000SER ALSTOM Time stamped Nbus O SW1000SER BACnet client - BTL certified Profile BACnet - ASHRAE E Native - Act B-AWS BACnet - ASHRAE BACnet Server E BACnet - ASHRAE BACnet/IP server - Profile B-ASC E BECKHOFF TwinCat over TCP/IP E TwinCat ADS Native PCI1000/2000/4000 CERBERUS CERLOOP Mo PCU1000 CITILOG IP-Citilog E Native COMMEND SA Commend OPC Server O COMMEND SA ICX E Native - Act CROUZET CBUS S Native DNP USER GROUP DNP3 Master station E Native - Act Manufacturer Protocol/Equipment Interface Requirement Version Manufacturer Protocol/Equipment Interface Requirement Version ECHELON LON Mb LCA Object Server Native MITSUBISHI FX 485 S Native ECHELON LON E NL220, LonMaker Native MITSUBISHI FX-Series S Native EIB OPC EIB O EIBA Server MITSUBISHI Melsec A-Series S Native PCI1000/2000/4000 MITSUBISHI Melsec TCP/IP for A and Q Series E Native
    [Show full text]
  • Industrial Bus World Introduction
    INTERBUS-S Modbus WHITE PAPER BITBUS/IEEE1118 PROFIBUS Optomux Data Highway, DH P-NET DMX512 Series 90, SNP and SNPx B+B SMARTWORX CONVERTERS FOR THE SUCOnet-K1 INDUSTRIAL BUS WORLD Measurement Bus/DIN 66348 INTRODUCTION What is an industrial bus? Traditionally, the industrial bus has industrial environment is greater noise immunity. This allows been used to allow a central computer to communicate with a greater distance between the transmitter and receiver. The a field device. The central computer was a mainframe or a downside to the greater distances provided by RS-422/485 mini (PDP11) and the field device could be a discreet device is the “difference of potential” between end points. such as a flow meter, temperature transmitter or a complex device such as a CNC cell or robot. As the cost of computing Industrial busses cover a large area. Often different areas of power came down, the industrial bus allowed computers the network are supplied by different power sources. Even to communicate with each other to coordinate industrial though all of the sources are grounded, a voltage difference production. can exist between the grounds of these voltage sources. This voltage difference can upset the data line in an RS- As with human languages, many ways were devised to 422/485 bus by pushing the signal voltage out of range and, allow the computers and devices to communicate and, as in some cases, an excess voltage can damage equipment. with their human counterpart, most of the communication Another source of excess voltage potential can be caused is incompatible with any of the other systems.
    [Show full text]
  • Iocontrol USER's GUIDE
    ioCONTROL USER’S GUIDE Form 1300-060515 —May, 2006 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080 Fax: 951-695-3017 Email: [email protected] Web: support.opto22.com ioControl User’s Guide Form 1300-060515 —May, 2006 Copyright © 2001–2006 Opto 22. All rights reserved. Printed in the United States of America. The information in this manual has been checked carefully and is believed to be accurate; however, Opto 22 assumes no responsibility for possible inaccuracies or omissions. Specifications are subject to change without notice. Opto 22 warrants all of its products to be free from defects in material or workmanship for 30 months from the manufacturing date code. This warranty is limited to the original cost of the unit only and does not cover installation, labor, or any other contingent costs. Opto 22 I/O modules and solid-state relays with date codes of 1/96 or later are guaranteed for life. This lifetime warranty excludes reed relay, SNAP serial communication modules, SNAP PID modules, and modules that contain mechanical contacts or switches. Opto 22 does not warrant any product, components, or parts not manufactured by Opto 22; for these items, the warranty from the original manufacturer applies. These products include, but are not limited to, OptoTerminal-G70, OptoTerminal-G75, and Sony Ericsson GT-48; see the product data sheet for specific warranty information. Refer to Opto 22 form number 1042 for complete warranty information.
    [Show full text]
  • CAT-6303 Openbas-HV-NXHALF
    BUILDING MANAGEMENT OpenBAS-HV-NXHALF • 4 Relay binary Outputs with a current capability of up to 5 Amps at 125 VAC or 28 VDC. Avoids unnecessary costs of externally mounted relays. • Powerful Configuration Software supports ladder templates and script programs for an effortless solution. Visually assemble building blocks for custom control sequences in any HVAC/building automation application. • Mircom’s enclosures, boxes, and power supplies provide installers with a single supplier source for all building automation needs. • Highly expandable with several expansion buses that allow the addition of diverse external modules. One full speed USB Description 2.0 port used to configure the controller and program the Mircom’s OpenBAS-HV-NXHALF Building Automation Controller application logic with the configuration tool software. aims to provide various HVAC, energy management, and lighting • Uniquely allows the support of up to 2 separate networks control solutions to offer building owners and managers seamless of BAS controllers simultaneously with two different operation. communication protocols. The NXHALF combines integrated control, supervision, data • DIN Rail mountable. logging, alarming, scheduling, and network management functions. • Each controller can be configured as a master and a slave With additional modular accessories, the NXHALF can be simultaneously through the available field buses. expanded to support web servers, email and SMS notifications. • Master controllers have the capability to support up to 50 The NXHALF is a microprocessor-based programmable controller remote points or 460 remote points with expanded memory. specially designed to control various building automation applications such as air handling units, chillers, boilers, pumps, cooling towers, and central plant applications.
    [Show full text]
  • Overview of Building Automation Protocols
    Considerations and challenges when integrating systems to achieve smart(er) buildings Lance Rütimann / SupDet 2015 / 04 March 2015 Unrestricted © Siemens AG 2015 All rights reserved. Integrating systems is not new … The technological development has advanced the dimension of integrations, both in quantitative and qualitative terms: . relay contacts . parallel data . serial data Cumulating events on one central point had its weaknesses. Unrestricted © Siemens AG 2015 All rights reserved. 04 March 2015 SupDet 2015 2 … but it has become more complex. And we continue to learn. Numbers of Protocols A protocol is a defined set of rules and regulations that determine how data is . 20+ Building Automation protocols transmitted in telecommunications . 35+ Process Automation protocols and computer networking . 4 Industrial Control System protocols . 4 Power System automation Source: http://en.wikipedia.org/wiki/List_of_automation_protocols Source: http://www.drillingcontractor.org/from-islands-to-clouds-the-data-evolution-10675 Distributed systems = increased redundancy Unrestricted © Siemens AG 2015 All rights reserved. 04 March 2015 SupDet 2015 3 Overview of Building Automation protocols 1. 1-Wire 14.Modbus (RTU or ASCII or TCP) 2. BACnet 15.oBIX 3. C-Bus 16.ONVIF 4. CC-Link Industrial Networks 17.VSCP 5. DALI 18.xAP 6. DSI 19.X10 7. Dynet 20.Z-Wave 8. EnOcean 21.ZigBee 9. HDL-Bus 10.INSTEON 11.IP500 12.KNX (previously AHB/EIB) 13.LonTalk Unrestricted © Siemens AG 2015 All rights reserved. 04 March 2015 SupDet 2015 4 Overview of Process Automation Protocols 1. AS-i 14.FINS 27.PieP 2. BSAP 15.FOUNDATION 28.Profibus 3. CC 16.HART 29.PROFINET IO 4.
    [Show full text]
  • Interop Forum 2007 Paper WORD Template
    Customer Energy Services Interface White Paper Version 1.0 Smart Grid Interoperability Panel B2G/I2G/H2G Domain Expert Working Groups Editor - Dave Hardin, EnerNOC, [email protected] Keywords: facility interface; ESI; SGIP; Smart Grid; (a.k.a. GWAC Stack)2 and NIST Framework and Roadmap standards for Smart Grid Interoperability Standards, Release 2.03. Abstract An ESI is a bi-directional, logical, abstract interface that The Energy Services Interface (ESI) is a concept that has supports the secure communication of information been identified and defined within a number of Smart Grid between internal entities (i.e., electrical loads, storage domains (e.g., NIST Conceptual Model1). Within these and generation) and external entities. It comprises the domains, an ESI performs a variety of functions. The devices and applications that provide secure interfaces purpose of this paper is to provide a common understanding between ESPs and customers for the purpose of and definition of the ESI at the customer boundary through facilitating machine-to-machine communications. ESIs a review of use case scenarios, requirements and functional meet the needs of today’s grid interaction models (e.g., characteristics. This paper then examines the information demand response, feed-in tariffs, renewable energy) and that needs to be communicated across the ESI, and looks at will meet those of tomorrow (e.g., retail market the standards that exist or are under development that touch transactions). the ESI. This is a general definition of an ESI as applied to the This white paper provides input to the Smart Grid customer boundary. Real implementations will have Interoperability Panel (SGIP) as well as international efforts variations arising from complex system inter-relationships: to understand grid interactions with the customer domain diverse customer business and usage models with different and the standards that govern those interactions.
    [Show full text]
  • Communication Protocols for Opto 22 Products C O Mmunication
    Communication Protocols for Opto 22 Products Introduction Opto 22 products—both current and legacy—provide a variety of protocols for communication and options for exchanging data. This technical note describes these protocols and data exchange options and lists the products 22 Products Opto for Protocols Communication that support them. It also describes the Opto 22 integration kits available for PAC Project and legacy products. For more information online and links to integration kits, go to www.opto22.com/lp/system_integration.aspx. If you have questions on supported protocols or the use of Opto 22 products, contact Pre-Sales Engineering by phone or email. Phone: 800-321-6786 (toll-free in the U.S.) or 951-695-3000 Email: [email protected] NOTE: Additional methods of communication developed by our user community may be found in the OptoForums at www.opto22.com. Protocol Descriptions The following table lists all communication protocols and data exchange options that may be supported in Opto 22 products. To see which products support which protocols, see “Supported Protocols and Toolkits by Product Group” on page 5. Industrial Internet Serial Parallel Data Exchange Options Ethernet Protocols Protocols Protocol Protocols Modbus RTU Modbus ASCII TCP/IP PROFIBUS DP UDP/IP DF12 OPC 2.0—OptoOPCServer OptoMMP SNMP DNP3 OPC 1.0—OptoServer Modbus/TCP SMTP BACnet MS/TP3 Pamux SQL database—OptoDataLink EtherNet/IP PPP1 CAN Mass storage—microSD card FTP Optomux Peer-to-peer—Scratch Pad HTTP mistic SSI TL1 TECHNICAL NOTE Form 1820-120806Form 1PPP is technically an Internet Protocol but requires a dial-up modem to connect.
    [Show full text]