NS-Series Programmable Terminals SETUP MANUAL

Total Page:16

File Type:pdf, Size:1020Kb

NS-Series Programmable Terminals SETUP MANUAL NS-Series NS15-TX01@-V2 Cat. No. V083-E1-32 NS12-TS00@-V1/-V2, NS12-TS01@-V1/-V2 NS10-TV00@-V1/-V2, NS10-TV01@-V1/-V2 NS8-TV00@-V1/-V2, NS8-TV01@-V1/-V2 NS8-TV10@-V1, NS8-TV11@-V1 NS5-SQ00@-V1/-V2, NS5-SQ01@-V1/-V2 NS5-TQ00@-V2, NS5-TQ01@-V2 NS5-MQ00@-V2, NS5-MQ01@-V2 NS5-SQ10@-V2, NS5-SQ11@-V2 NS5-TQ10@-V2, NS5-TQ11@-V2 NS5-MQ10@-V2, NS5-MQ11@-V2 Programmable Terminals SETUP MANUAL ©OMRON, 2003 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. Trademarks • Microsoft, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • This product includes software developed by the Apache Software Foundation (http://www.apache.org/). Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. Notice OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. ! DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Additionally, there may be severe property damage. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Additionally, there may be severe property damage. ! Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. OMRON Product References All OMRON products are capitalized in this manual. The word "Unit" is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation "Ch," which appears in some displays and on some OMRON products, often means "word" and is abbreviated "Wd" in documentation in this sense. The abbreviation "PLC" means Programmable Controller. The abbreviation "host" means a controller, such as an IBM PC/AT or compatible computer, that controls a PT (Programmable Terminal). Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Precautions Indicates precautions on handling the product to ensure that the product is used for Safe Use safely. Precautions Indicates precautions to ensure that product functions and performances are for Correct Use realized, to ensure that the reliability of the product is maintained, and to ensure that the product is otherwise used correctly. Note Indicates information of particular interest for efficient and convenient operation of the product. Reference Indicates supplementary information on procedures, descriptions, and settings. 1, 2, 3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc. CS1G-CPU@@-V1 Boxes in model numbers indicate variable characters. For example, "CS1G-CPU@@-EV1" indicates the following models: CS1G-CPU42-EV1, CS1G-CPU43-EV1, CS1G-CPU44-EV1, and CS1G-CPU45-EV1. 1 Contents Notice ............................................................................................................................................. 1 About this Manual ............................................................................................................................... 7 Related Manuals .................................................................................................................................. 8 Terminology ........................................................................................................................................ 9 Introduction ....................................................................................................................................... 10 Section 1 Overview ................................................................................................ 1-1 1-1 NS-series PT Functions and Operation ............................................................................................ 1-2 1-1-1 PT Functions for FA Manufacturing Sites ........................................................................... 1-2 1-1-2 NS-series PT Operating System ........................................................................................... 1-3 1-2 Communications with the Host ....................................................................................................... 1-5 1-2-1 What is an NT Link? ............................................................................................................ 1-6 1-2-2 Ethernet ................................................................................................................................ 1-6 1-2-3 Controller Link ..................................................................................................................... 1-6 1-2-4 Host Link ............................................................................................................................. 1-6 1-2-5 Connecting to a Temperature Controller .............................................................................. 1-6 1-2-6 Memory Link Connections .................................................................................................. 1-7 1-2-7 Communicating with Other Devices .................................................................................... 1-7 1-2-8 EtherNet/IP .......................................................................................................................... 1-7 1-3 System Configuration ...................................................................................................................... 1-8 1-3-1 Supported Peripheral Devices .............................................................................................. 1-8 1-4 Procedure for Running NS-series PTs ........................................................................................... 1-10 Section 2 Before Connecting .................................................................................. 2-1 2-1 Connecting the Host ........................................................................................................................ 2-2 2-1-1 Communications Types and Connection Methods ............................................................... 2-2 2-2 Part Names and Functions ............................................................................................................... 2-8 Section 3 Installing the PT and Connecting Peripheral Devices ........................ 3-1 3-1 Installing the PT .............................................................................................................................. 3-3 3-1-1 Installation Environment ...................................................................................................... 3-3 3-1-2 Installing RS-232C/RS-422A Converters ............................................................................ 3-3 3-1-3 Mounting the PT to the Control Panel ................................................................................. 3-4 3-1-4 Connecting the Power Supply .............................................................................................. 3-7 3-1-5 Wiring the Ground Wire ...................................................................................................... 3-8 3-1-6 Peripheral Device Connection Limitations .......................................................................... 3-8 3-2 Starting the PT ............................................................................................................................... 3-10 3-2-1 Operation at Startup ........................................................................................................... 3-10 3-2-2 Starting the PT for the First Time ...................................................................................... 3-12 3-3 Connecting the CX-Designer ......................................................................................................... 3-14 3-3-1 Connecting via RS-232C or Ethernet ................................................................................. 3-14 3-3-2 Connecting via USB........................................................................................................... 3-14 3-3-3 Connecting via a Modem ................................................................................................... 3-16 3-4 Connecting to Bar Code Readers ................................................................................................... 3-17
Recommended publications
  • Lighting Controls
    LIGHTING CONTROLS HUMIDITY CONTROLS LIGHTING Kele Provides System and Zone Controls, with a Wide Variety of Peripheral Sensors and Switches. DLM Series | p. 615 AF16 Series | p. 664 LX-24 | p. 624 WSD Series | p. 637 CI-24 | p. 626 ET Series | p. 674 LIGHTING CONTROLS Products manufactured MODEL/SERIES PAGE in the United States Emergency Lighting Control ELCU-100 — WattStopper Emergency Lighting Control . 666 Products that are ELCU-200 — Emergency UL924 Bypass/ Shunt Relays . 668 new to the catalog ESR Series — Functional Devices UL924 Emergency Bypass / Shunt Relays . 670 Light Sensors MK7-B Series — PLC-Multipoint Celestial Self-Contained Ambient Light Sensors, Voltage Based . 643 PSR-1, PSR-1-T — Kele Photo-Sensitive Resistor . 645 K, LC Series — Photo Switches . 647 EM Series — Photo Switches . 649 MAS Series — PLC-Multipoint Self-Contained Ambient Light Sensors, Current Based . 650 Lighting Contactors and Relays HDR — Relay 5 Wire with Override and Connector . 660 RR-7, RR-9 — GE Lighting Relays . 661 2R7CDD, 2R9CDD — ILC Lighting Relays . 663 AF16 Series — ABB Lighting Contactors . 664 LIGHTING CONTROLS LS7K Series — AEG Lighting Contactors . 665 LMCP Series | p. 613 Lighting Panels and Control Products RP Basic Series — BlueRidge Relay Panels . 609 ZC Basic Series — BlueRidge Lighting Zone Controller . 611 LMCP Series — WattStopper Lighting Integrator Panels with Digital Lighting Management (DLM) Support . 613 DLM Series Digital Lighting Management — Digital Lighting Controls . 615 LC8 Series — WattStopper Modular Contractor Panel . .. 618 CX Series Commercial Lighting Control Panels — Standalone Programmable Lighting Control Panel . 620 ILC Apprentice II — Programmable Lighting Control Panel . 622 PIL-1 — Kele Pulse Initiator . 658 LDIM2 — Kele Fluorescent Dimming Control Module .
    [Show full text]
  • DUCT HUMIDITY SERIES Phone: 1-888-967-5224 Installation & Operation Instructions Website: Workaci.Com
    DUCT HUMIDITY SERIES Phone: 1-888-967-5224 Installation & Operation Instructions Website: workaci.com GENERAL INFORMATION FIGURE 1: ENCLOSURE DIMENSIONS The A/RH Duct Series Sensor is a Relative Humidity EURO (-EH) 3.80" transmitter that can be powered with either an AC or (96.56 mm) 4.30" (109.22 mm) 1.90" DC supply voltage. The RH Duct transmitter is eld (48.28 mm) selectable with a 4-20 mA, 0-5 VDC, or 0-10 VDC output signal that is equivalent to 0 to 100% RH. This sensor is designed for use with electronic controllers in commer- cial heating and cooling building management systems. All units are shipped from the factory set up for a 4-20 mA output. The transmitter can also include an optional temperature sensor for monitoring the space temperature. 2.12" 7.94" (53.72 mm) (201.60 mm) For optimal readings, follow these tips: • The sensor should be mounted in the middle of the duct ø: 0.75" where air circulation is well mixed (no stratication), and (19.05 mm) not blocked by obstructions. Stratication and obstructions can cause sensing errors. An example is downstream from a heating or cooling coil. • Duct probe should be placed (3) to (4) duct NEMA (-4X) segments down from any bend or obstructions and 1.96" 2.55" (49.78 mm) away from 90° bends. (64.77 mm) 0.98" (24.89 mm) • Mount the sensor on the top or sides of duct work; mounting on the bottom risks damage due to moisture. 3.11" MOUNTING INSTRUCTIONS (78.99 mm) The Euro enclosure (-EH) requires a 0.875” (22.23 mm) 3.70" hole in the duct, and the Nema 4X enclosure (-4X) (93.98 mm) 1.56" requires a 1.25” (31.75 mm) hole - see FIGURE 1.
    [Show full text]
  • MP Series Modular Photoelectric Sensors
    Photoelectric Sensors MP Series Modular Photoelectric Sensors Photoelectric • Harsh Duty • Modular design - Exchangeable rotatable heads - Limit switch and mini style plug-in bases - Screw terminal, preleaded, and connector version receptacles MP Series Modular • Withstands 1200 psi washdown, IP69K • 6 A SPDT and 5 A DPDT relay MP Series modular sensors enable users to customize a sensing solution for almost any models application. For this reason, the components of • Multifunction timer/logic cards this series are sold separately. Refer to pages available 594-595 for instruction on how to assemble an MP Series sensor. • DC, AC, AC/DC models Diffuse Retro-Reflective Mode Mode Sensing Ranges: 300 mm, 450 mm, 760 mm, Features: 900 mm, 1.3 m, 1.8 m, 3 m • Polarization filter to detect shiny objects Outputs: Dependent on base selected Sensing Ranges: 4.5 m, 6 m, 9 m Outputs: Dependent on base selected Thru-Beam Fiber Optic Mode Mode Sensing Ranges: 36 m, 60 m Sensing Ranges: Dependent on fibers selected Outputs: Dependent on base selected Outputs: Dependent on base selected See page 610-620 for MP Series sensing charateristics, wiring, dimensions and accessories. Subject to modifications without notice Copyright Pepperl+Fuchs Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776-4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com [email protected] [email protected] [email protected] 593 BUILD AN SELECT MP SENSOR 1. A HEAD 1 2 3 Head Plug-in/DPDT Relay Base SPDT Relay Base Mini Style Base Receptacle
    [Show full text]
  • Products Catalog Index
    Products Catalog Index PART NO. MANUFACTURER DESCRIPTION URL PRICE B3-32341 OTTO Basic / Snap Action http://www.products.express/ottoexcellence.com/B3-32341.html QUOTE Switches 8A SPDT- DB Turret 1/8 High Current B3-24232 OTTO Basic / Snap Action http://www.products.express/ottoexcellence.com/B3-24232.html QUOTE Switches 8A SPDT Wire Wrap Low Current MIL K2ABBPEEJA OTTO Rocker Switches http://www.products.express/ottoexcellence.com/K2ABBPEEJA.html QUOTE RockerSwitch Sealed 1-C1 NONE 2-C1 SPDT TIGG5E-1S-WH-FN Carling Technologies Rocker Switches http://www.products.express/carlingtech.com/TIGG5E-1S-WH-FN.html QUOTE FSM4JLH TE Connectivity / Tactile Switches http://www.products.express/te.com/FSM4JLH.html QUOTE Alcoswitch 6MM H/T PBT BR TACTILE SWITCH TPC11CGVRA0 TE Connectivity / Pushbutton Switches http://www.products.express/te.com/TPC11CGVRA0.html QUOTE Alcoswitch SPST 0.137" T/H BLK PUSHBUTTON SWITCH PREDD4-07F-BB000 TE Connectivity Rocker Switches http://www.products.express/te.com/PREDD4-07F-BB000.html QUOTE PWR ROCKER BLK ON-OFF-(ON) A01PC NKK Switches Industrial Panel http://www.products.express/nkkswitches.com/A01PC.html QUOTE Mount Indicators / Switch Indicators RED LED INDICATOR STRAIGHT PC MNT GDH08SATR04 TE Connectivity / DIP Switches / SIP http://www.products.express/te.com/GDH08SATR04.html QUOTE Alcoswitch Switches SPST 8POS DIP Rocker BZ-3YT552 Honeywell Basic / Snap Action http://www.products.express/honeywell.com/BZ-3YT552.html QUOTE Switches LARGE BASICS K1ABBAAAAA-USA OTTO Rocker Switches http://www.products.express/ottoexcellence.com/K1ABBAAAAA-USA.html
    [Show full text]
  • Wireless Signal Receiver Switch INSTALLATION INSTRUCTIONS
    Single Pole (One Location) Wireless Signal Receiver Switch Cat. No. WSS10 (Advanced) Incandescent: 800W @ 120V – Ballast: 1200VA @ 120V, 2700VA @ 277V 120-277VAC, 50/60Hz, Motor: 1/4 HP @ 120V INSTALLATION INSTRUCTIONS WARNINGS AND CAUTIONS: WARNINGS AND CAUTIONS: • DISCONNECT POWER AT CIRCUIT BREAKER OR FUSE WHEN SERVICING, INSTALLING OR REMOVING THE WSS10. • WSS10-GDx products do not require a neutral wire, there is a minimum load requirement of 25 watts for these products. • To be installed and/or used in accordance with appropriate electrical codes and regulations. • Recommended minimum wall box depth is 2-1/2”. • If you are unsure about any part of these instructions, consult an electrician. • Use this device with copper or copper clad wire only. PK-93664-10-00-0E Figure 2 - No Neutral Switch Time-Outs: Description Installation (no white wire) The Sensor has four time-out settings: 2 (test), 10, 20, or 30 min. (longer timeout BK Hot (Black) is recommended for self powering in dark spaces). The values of time-out is user Cat. No. WSS10 is the receiver switch. This switch has a single switch pad that NOTE: Use check boxes √ when Steps are completed. selected through the use of the Dip Switch Settings. NOTE: Since the sensor is toggles the relay and its corresponding load, ON and OFF. If the relay is OFF, the only sending a packet every minute, the 2 minute time delay is not sufficient for relay will turn ON when the push-button is pressed, and vice-versa. The Indicator WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN Step 1 BL normal operation.
    [Show full text]
  • Switch Contents
    Switch Contents 1 Switch 1 1.1 Description .............................................. 1 1.2 Contacts ................................................ 2 1.2.1 Contact terminology ..................................... 2 1.2.2 Contact bounce ........................................ 3 1.2.3 Arcs and quenching ...................................... 3 1.2.4 Power switching ....................................... 3 1.2.5 Inductive loads ........................................ 4 1.2.6 Incandescent loads ...................................... 4 1.2.7 Wetting current ........................................ 4 1.3 Actuator ................................................ 4 1.3.1 Biased switches ........................................ 4 1.3.2 Rotary switch ......................................... 4 1.3.3 Toggle switch ......................................... 5 1.4 Special types .............................................. 6 1.4.1 Mercury tilt switch ...................................... 6 1.4.2 Knife switch .......................................... 6 1.4.3 Footswitch .......................................... 6 1.4.4 Reversing switch ....................................... 7 1.5 Light switches ............................................. 7 1.6 Electronic switches .......................................... 7 1.7 Other switches ............................................. 7 1.8 See also ................................................ 8 1.9 References .............................................. 8 1.10 External links ............................................
    [Show full text]
  • Series 800 Steam Humidifier Installation & Maintenance
    Steam Humidifier Series 800 Steam Humidifier Installation & Maintenance Instructions TABLE OF CONTENTS Safety Cautions . 2 Install Steam Hose . 14 Materials List . 3 Supply Water . 14 Principles & Sequence of Operation . 4 Drain Line . 15 Specifications & Dimensions . 5 Electrical Power Wiring & Shut-off Switch . 15 Installation Instructions . 8 Automatic Digital Control and Accessory Wiring . 20 Choosing a Location . 8 Manual Digital Humidistat and Fan Pack Wiring . 21 - Dispersion Tube Location . 8 Automatic Digital Modulating Control Wiring . 22 - Fan Pack Location . 10 Start-up Procedure . 24 - Elevation . 11 Operating Modes . 25 - Distance from Humidifier to Dispersion Tube/Fan Pack . 12 Shut Down Procedure . 26 - Humidifier Location . 13 Display Panel . 26 Prepare Humidifier for Mounting . 14 Maintenance . 27 Install Steam Dispersion Tube/Fan Pack . 14 Troubleshooting Guide . 28 Mount Humidifier . 14 Replacement Parts . 31 READ AND SAVE THESE INSTRUCTIONS SAFETY CAUTIONS CAUTION AttENTION INSTALLER Read this manual before installing. This product must be installed by qualified HVAC and electrical contractors and in compliance with local, state, federal, and governing codes. Improper installation can cause property damage, severe personal injury, or death as a result of electric shock, burns, or fire. Read all cautions and instructions. Read this manual before performing service or maintenance procedures on any part of the system. Failure to follow all cautions and instructions could produce the hazardous situations described, resulting in property damage, personal injury, or death. Failure to follow the instructions in this manual can cause moisture to accumulate, which can cause damage to structure and furnishings. HOT SURFACES AND HOT WATER This steam humidification system has extremely hot surfaces.
    [Show full text]
  • Español English Français a Prueba De Fallos Fail Safe Protégé En Cas De
    Español English Français a prueba de fallos fail safe protégé en cas de défaut abrasivo abrasive abrasif abrazadera de cable cable clamp collier de câble absorción absorption absorption acabado finish apprêt acceso aleatorio random access accès aléatoire acceso secuencial serial access accès séquentiel accionador actuator actionneur accionador con motor electric motor actuator actionneur à moteur eléctrico électrique accionador de frecuencia variable frequency driver actionneur à fréquence variable variable accionador eléctrico electric actuator actionneur électrique accionador eléctrico electric driver actionneur électrique accionador eléctrico electrical actuator actionneur électrique accionador eléctrico electrical driver actionneur électrique accionador eléctrico lineal linear electric actuator actionneur électrique linéaire accionador electromecánico electromechanical actuator actionneur électromagnétique aceleración ramp-up accélération acelerador accelerator accélérateur acelerador gráfico graphics accelerator accélérateur graphique acelerómetro accelerometer accéléromètre aceptor acceptor accepteur acetona acetone acétone ácido acid acide ácido acético acetic acid acide acétique ácido bromhídrico hydrobromic acid acide bromhydrique ácido clorhídrico hydrochloric acid acide chlorhydrique ácido fluorhídrico hydrofluoric acid acide fluorhydrique ácido fluorhídrico buffered hydrofluoric acid acide fluorhydrique tamponado tamponné ácido fosfórico phosphoric acid acide phosphorique ácido nítrico nitric acid acide nitrique ácido peroxidisulfúrico
    [Show full text]
  • MCT-302 Is a Fully Supervised, Powercode Magnetic Contact a Periodic Supervision Message, Distinguished by a Specific Marker, Transmitter
    0&7 Supervised PowerCode Magnetic Contact Transmitter Installation Instructions ,1752'8&7,21 The MCT-302 is a fully supervised, PowerCode magnetic contact A periodic supervision message, distinguished by a specific marker, transmitter. It features a built-in reed switch (that opens upon is transmitted automatically from the reed switch input only (if removal of a magnet placed near it) and an auxiliary hard-wired input, enabled) or from the auxiliary input only (if the reed switch is programmable as either N.C. or E.O.L., for use with additional sensors disabled) once in 60 minutes. The target receiver is thus informed, at - pushbuttons, detectors, door contacts etc. regular intervals, of the unit’s active participation in the system. An on-board DIP switch allows the installer to disable the magnet- An LED lights whenever alarm or tamper events are reported. The operated reed switch if only the auxiliary input is needed. LED does not light while a supervision message is being transmitted. The reed switch and the auxiliary input behave as separate trans- Operating power is obtained from an on-board 3.6 V Lithium Thionyl mitters, although they trigger the same RF module into transmission. Chloride battery. A weak battery will cause a “low battery” marker to Each input has a unique 24-bit PowerCode ID, selected in the factory be added to any message transmitted. from over 16 million possible code combinations. Upon alarm, a digital message is transmitted, composed of the disturbed input’s PowerCode ID followed by various status and message-type markers. Alarm and other data are thus forwarded to the receiver.
    [Show full text]
  • B6J Jog Lever Switch Data Sheet
    DIP Switch A6A Subminiature DIP Switch for High-Density Packaging ■ Subminiature size (10 x 10 x 7.5 mm), ideal for high-density packaging ■ Completely sealed construction prevents flux entry during automatic flow soldering ■ BCD and hexadecimal types available (each complement type also available) ■ Position switching operation possible with a turn of a screwdriver from either top and side; the screwdriver slot on the top can rotate in either direction for desired setting ■ Thumbwheel and extended shaft type also available Ordering Information Part numbers No. of switching Standard Flat Extended Shaft Thumbwheel Output code type positions type type type type BCD 1-2-4-8 10 A6A-10R A6A-10RF A6A-10RS A6A-10RW BCD 1-2-4-8 complement only 10 A6A-10C A6A-10CF A6A-10CS A6A-10CW Hexadecimal 1-2-4-8 16 A6A-16R A6A-16RF A6A-16RS A6A-16RW Hexadecimal 1-2-4-8 16 A6A-16C A6A-16CF A6A-16CS A6A-16CW complement only Important note: Switches cannot be water-washed. 191 A6A A6A Specifications ■ CHARACTERISTICS Switching capacity 1 to 100 mA, 5 to 28 VDC Carry current 100 mA, 50 VDC (max.) Contact resistance 200 MΩ max. Insulation resistance 10 MΩ min. (at 250 VDC) Dielectric strength 500 VAC for 1 minute between current-carrying metal part and ground 250 VAC for 1 minute between terminals of same polarity Operating force 120 to 250 g-cm Vibration Malfunction durability 10 to 55 Hz, 1.5 mm double amplitude Shock Malfunction durability Approx. 300 m/s2 (30 G) Materials Base/Cover PBT (Polybutylene terephthalate) Dial/Rotor Polyacetal O-ring Acryl nitril butadiene rubber Movable contact Phosphor bronze plated with Ag/Au clad Terminal Beryllium copper Ambient temperature -10° to 70°C Humidity 45% to 85% RH Service life Mechanical 10,000 detent operations min.
    [Show full text]