Ion Beam Analysis : a Century of Exploiting the Electronic and Nuclear Structure of the Atom for Materials Characterisation

Total Page:16

File Type:pdf, Size:1020Kb

Ion Beam Analysis : a Century of Exploiting the Electronic and Nuclear Structure of the Atom for Materials Characterisation Subsequently published by: Reviews of Accelerator Science and Technology Vol. 4 (2011) 41-82 (World Scientific Publishing Company) C. Jeynes, University of Surrey Ion Beam Centre, 22 nd September 2011 ION BEAM ANALYSIS : A CENTURY OF EXPLOITING THE ELECTRONIC AND NUCLEAR STRUCTURE OF THE ATOM FOR MATERIALS CHARACTERISATION CHRIS JEYNES University of Surrey Ion Beam Centre Guildford GU2 7XH, England [email protected] ROGER P. WEBB University of Surrey Ion Beam Centre [email protected] ANNIKA LOHSTROH Department of Physics, University of Surrey [email protected] Analysis using MeV ion beams is a thin film characterisation technique invented some 50 years ago which has recently had the benefit of a number of important advances. The review will cover damage profiling in crystals including studies of defects in semiconductors, surface studies, and depth profiling with sput- tering. But it will concentrate on thin film depth profiling using Rutherford backscattering, particle in- duced X-ray emission and related techniques in the deliberately synergistic way that has only recently be- come possible. In this review of these new developments, we will show how this integrated approach, which we might call " Total IBA ", has given the technique great analytical power. Keywords : RBS, EBS, PIXE, ERD, NRA, MEIS, LEIS, SIMS, IBIC. 1. Introduction gies, including the semiconductor, sensor, mag- netics, and coatings industries (including both Ion beam analysis is a very diverse group of char- tribology and optics), among others. It is also acterisation techniques which have been applied to valuable in many other disparate applications such every class of material where the interest is in the as cultural heritage, environmental monitoring and surface or near-surface region up to a fraction of a forensics. We will be describing examples in many mm in thickness. Such a field is far too broad to be of these areas in our review of MeV-IBA. reasonably covered by such a review as this; we Historically, IBA labs have tended to split into will concentrate on thin film elemental depth (at least) two "traditions": on the one hand nuclear profiling methods using ions with energies of order methods (RBS, ERD, NRA), and on the other 1 MeV/nucleon. We will emphasise complemen- atomic methods (PIXE). We will outline various tary techniques, including some other closely reasons for this, but will show that recent advances I related IBA methods. have facilitated the integration of these two tradi- Thin film elemental depth profiling is of critical tions giving us what is effectively a new and much importance to a wide variety of modern technolo- more powerful technique. Curiously, this review seems to touch on all the th I see the end of the chapter for expansion and explanation of main breakthroughs in 20 century physics, and all acronyms. Appendix A is a glossary of IBA techniques, and IBA techniques hinge on spectroscopy. So perhaps Appendix B is a glossary of related techniques. we should start by acknowledging our debt to Isaac 1 2 Jeynes, Webb & Lohstroh Newton, who in 1671 was the first to use the word ants)IV , the scanning probe microscopies (AFM "spectrum " with the modern connotation of quan- and variants including the new optical near-field tum phænomenon observed with a dispersive methods), X-ray techniques like XRF and XRD mechanism [1] II . Previously (and subsequently) (also with many variants) and optical methods like "spectrum" had the connotation of "spectre" or ellipsometry, Raman, FTIR and other spectro- "apparition". But philosophers see reality. scopies. Elemental depth profiling can be done destructively using sputtering techniques with 1.1. Scope of chapter SIMS (or, frequently, AES). If destructive tech- niques are considered then bulk methods like Although concentrating on MeV IBA depth profil- ICP-MS and AMS should be mentioned, and of ing, we will mention methods of depth profiling course there are a wide variety of wet chemical crystallographic defects using channelling and analytical methods. XRF and XRD are frequently MEIS; characterising defects in semiconductors, applied to "bulk" as well as thin film samples, and including their spacial distribution, by IBIC; and other comparable fluorescence techniques are depth profiling using sputtering by SIMS (includ- cathodoluminescence or photoluminescence. ing MeV-SIMS), although we will not discuss Molecular imaging can already be done in air by beam damage extensively. We will also mention MALDI, DESI and DART. ion beam methods sensitive to the true surface Where does IBA fit in this kaleidoscope of tech- (MEIS, LEIS) since they also use RBS. niques? IBA typically uses an accelerator which We will not specifically review microbeam ap- needs a hall of at least 200m 2, a footprint well over plications, taking microbeam technology for an order of magnitude larger than any of the other granted throughout the text. But it will be clear techniques mentioned – it is necessarily a technique that we think that 3D spacial resolution is central to with high running costs. What can it do which the general usefulness of IBA. cannot be done reasonably easily by other tech- niques? If a materials research organisation (for 1.2. Complementary techniques example, a University) were to set up a central Throughout, we will also mention complementary analytical laboratory to service the needs of all its techniques wherever appropriate. Materials analy- research groups and other collaborators, would sis must be a strongly interdisciplinary field, and IBA be one of the techniques considered "essen- the characterisation problems of modern materials tial"? almost invariably require the use of a variety of We believe that modern integrated IBA meth- techniques for their solution. Any discussion of a ods are exceptionally powerful for a wide range of technique without the context of complementary materials problems, and we will show a number of techniques is likely to be strongly misleading. significant examples that exemplify this. In all these fields the analyst has various stan- 1.3. Overview of chapter dard tools: the electron microscopies and spectro- scopies III (SEM, TEM, XPS, AES and their vari- In §§2, 4 we will summarise the nuclear and atomic IBA techniques we will be concentrating on, and II Using Newton's spelling of "phænomenon" which transliterates in §6 we will address their integration. §3 will the Greek φαινοµενον . In his use of "spectrum" Newton had in mind the Latin etymology of specere , to see. III "spectrometry" or "spectroscopy"? A spectrum is the object lines has shifted to different frequencies. However, the boundary that results from some dispersive process: we do spectrometry between spectroscopy (as in XPS) and spectrometry (as in RBS) is where we measure the spectrum and spectroscopy where we look ill-defined, and it is mostly a conventional distinction. at the spectrum. The Hubble red-shift for example is a spectro- IV see Appendix B for a glossary expanding and explaining scopic effect since the recognisable pattern of atomic absorption acronyms for complementary characterisation techniques. Ion Beam Analysis 3 briefly describe the other IBA techniques, for a tors were available, with the first paper by Georges more complete overview of the field. In §5 we will Amsel on Si diode detectors in 1960 [19] and Turke- discuss the important issue of computer codes used vich's immediate proposal for the Surveyor Moon in IBA, together with a further discussion of the mission in 1961 [20] with the report in 1967 [21]. high accuracy available with these methods. Explicit depth profiles were not published until 1970 A general introduction to the field must mention [22]. the three IBA Handbooks published over the last 35 years. The 1977 "green book" [2] includes a sec- 2.1. Energy loss tion on PIXE which was dropped from the more It was obvious to all the early workers that the extensive "black book" from 1995 [3]. PIXE is energy loss of scattered particles represented depth restored in the recent 2-volume Handbook [4]. in the samples, and the famous Bragg rule (1905) There have been an almost unbroken series of [23] obtained the compound stopping power for a biennial IBA Conferences, the first of which was fast particle from a linear combination of elemental held in 1973 [5]. Currently the most recent pub- stopping powers. lished Proceedings are from the Cambridge confer- To interpret IBA spectra in general it is essen- ence in September 2009 [6]: the Proceedings are tial to have energy loss ("stopping power") data for not yet available from the Brazil conference of the whole periodic table and all the ion beams of April 2011. There is also a triennial PIXE confer- interest. This is a massive task both of measure- ence series, the latest of which was in Surrey in ment and of evaluation against a theoretical model. 2010 [7]. Other useful recent reviews include The measurements are difficult to make and the Giuntini (2011) on the use of external beams [8]. model enables both a valid comparison between different sets and also extrapolation to materials or 2. Nuclear IBA depth profiling methods beams for which measurements are not available. Large angle ion scattering was first observed in Happily this has been done, with comprehensive Geiger & Marsden's experiments in 1909 [9], which stopping power databases now available from Jim were interpreted by Ernest Rutherford in 1911 to Ziegler's SRIM website [24] [25] [26]. Helmut demonstrate the existence of the positively charged Paul has also recently reviewed this field with atomic nucleus [10]. The transition from RBS to references to other compilations (H.Paul [27], EBS as the Coulomb barrier is exceeded was first MSTAR, ICRU…) [28]. demonstrated by Chadwick & Bieler in 1921 (for The Bragg rule is an approximation that clearly alphas on H [11]).
Recommended publications
  • Laser Raman Microprobing Techniques P
    LASER RAMAN MICROPROBING TECHNIQUES P. Dhamelincourt, J. Barbillat, M. Delhaye To cite this version: P. Dhamelincourt, J. Barbillat, M. Delhaye. LASER RAMAN MICROPROBING TECHNIQUES. Journal de Physique Colloques, 1984, 45 (C2), pp.C2-249-C2-253. 10.1051/jphyscol:1984255. jpa- 00223968 HAL Id: jpa-00223968 https://hal.archives-ouvertes.fr/jpa-00223968 Submitted on 1 Jan 1984 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. JOURNAL DE PHYSIQUE Colloque C2, suppldment au n02, Tome 45, fdvrier 1984 page C2-249 LASER RAMAN MICROPROBING TECHNIQUES P. Dhamelincourt, J. Barbillat and M. Delhaye Laboratoire de Spectrochimie Infrarouge et Raman, C. N. R. S., lhziversitB des Sciences et Techniques de LiZZe, B&. C. 5, 59655 ViZZeneuve d 'Ascq Cedex, France @sun6 - L1int6r&t de la microspectrcm6trie Raman pour l'analyse mol6culaire non destructive ainsi que 1'6volution des techniques sont pr6sentBs. Quelques exem- ples d'application illustrent l'exps6. Abstract - The analytical potential of micr0Fm-w spectroscopy for non des- tructive mlecular analysis is presented.
    [Show full text]
  • Electron Microprobe Analysis Course 12.141 Notes MIT Electron
    Electron Microprobe Analysis Course 12.141 Notes Dr. Nilanjan Chatterjee The electron microprobe provides a complete micron-scale quantitative chemical analysis of inorganic solids. The method is nondestructive and utilizes characteristic x-rays excited by an electron beam incident on a flat surface of the sample. This course provides an introduction to the theory of x-ray microanalysis by wavelength and energy dispersive spectrometry (WDS and EDS), ZAF matrix correction procedures, and scanning electron imaging techniques using backscattered electron (BE), secondary electron (SE), x-ray (elemental mapping), and cathodoluminescence (CL) signals. Lab sessions involve hands- on use of the JEOL JXA-8200 Superprobe. MIT Electron Microprobe Facility Massachusetts Institute of Technology Department of Earth, Atmospheric & Planetary Sciences Room: 54-1221, Cambridge, MA 02139 Phone: (617) 253-1995; Fax: (617) 253-7102 e-mail: [email protected] web: http://web.mit.edu/e-probe/www/ Nilanjan ChatterjeeMIT, Cambridge, MA, USA October 2017 2 TABLE OF CONTENTS Page number 1. INTRODUCTION 3 2. ELECTRON SPECIMEN INTERACTIONS 5 2.1. ELASTIC SCATTERING 5 2.1.1. Electron backscattering 5 2.1.2. Electron interaction volume 6 2.2. INELASTIC SCATTERING 7 2.2.1. Secondary electron generation 7 2.2.2. Characteristic x-ray generation: inner-shell ionization 7 2.2.3. X-ray production volume 10 2.2.4. Bremsstrahlung or continuum x-ray generation 11 2.2.5. Cathodoluminescence 12 3. QUANTITATIVE X-RAY SPECTROMETRY 13 3.1. MATRIX CORRECTIONS 14 3.1.1. Atomic number correction (Z) 14 3.1.2. Absorption correction (A) 16 3.1.3.
    [Show full text]
  • Microprobe Operating Procedure
    TWS-ESS-DP-07, R3 MICROPROBE OPERATING PROCEDURE Effective Date $1fj3 O/il ga" A*4,- Roland Hagan Date Preparer / /A Dad-, David Vaniman Technical Reviewer =AQ vc) Henry Paul Nunas Date Quality Assurane Project Leader TechnicaMrojeci Officer .B912190174 891211 -N !PDR WASTE WM-11 PDC TWS-ESS-DP-07, R3 Page 1 of 11 MICROPROBE OPERATING PROCEDURE 1.0 PURPOSE The purpose of this procedure is to allow an investigator to bring the Electron Microprobe from a standby condition to an analysis condition, perform one or more analyses, and when finished, return the system to a standby condition. 2.0 SCOPE This procedure describes the start-up, calibration, quantitative analysis and shut-down routines for the Electron Microprobe. Requirements for Los Alamos Yucca Mountain Project (LA YMP) analytical work are listed throughout this procedure. 3.0 APPLICABLE DOCUMENTS Documents referenced in this procedure are: Cameca Technical Manual, Option A-21 Tracor Northern Operators Manual, 1988 SANDIA TASKS: A Subroutined Electron Microprobe Automation system, Sandia Report 2037, 1985 CONFIG8 A Configuration File Generator for SANDIA TASKS, Sandia Report TWS-ESS-DP-06, 2035,1985 Operating Instructions For the Ladd Vacuum Evaporator For Carbon Coating TWS-ESS-DP. 122, Preparation of Electron Microprobe Standard Mounts TWS-ESS-DP-101, Procedure for Identification and Control for Mineralogy-Petrology TWS-QAS-QP-02.1, Los Alamos YMP Personnel Certification Procedure TWS-ESS-DP-125, Certification of Standards for Microanalysis TWS-QAS-QP.3.1, LANL, Yucca Mo ain Project Computer Software Control 4.0 RESPONSIBILrITES 4.1 It is the responsibility of the Operator to ascertain that all Electron Microprobe systems are operational before an Investigator begins a microanalysis session.
    [Show full text]
  • Electron Probe Microanalysis
    Electron probe microanalysis Essential Knowledge Briefings First Edition, 2015 2 ELECTRON PROBE MICROANALYSIS Front cover image: high-resolution X-ray maps of copper (Cu), zinc (Zn) and silver (Ag) illustrating the interdiffusion zone between the main material (Cu) and the brazing material (Ag-Zn). Data acquired with the SXFiveFE at 10keV, 30nA © 2015 John Wiley & Sons Ltd, The Atrium, Southern Gate, Chichester, West Sussex PO19 8SQ, UK Microscopy EKB Series Editor: Dr Julian Heath Spectroscopy and Separations EKB Series Editor: Nick Taylor ELECTRON PROBE MICROANALYSIS 3 CONTENTS 4 INTRODUCTION 6 HISTORY AND BACKGROUND 13 IN PRACTICE 22 PROBLEMS AND SOLUTIONS 28 WHAT’S NEXT? About Essential Knowledge Briefings Essential Knowledge Briefings, published by John Wiley & Sons, comprise a series of short guides to the latest techniques, appli - cations and equipment used in analytical science. Revised and updated annually, EKBs are an essential resource for scientists working in both academia and industry looking to update their understanding of key developments within each specialty. Free to download in a range of electronic formats, the EKB range is available at www.essentialknowledgebriefings.com 4 ELECTRON PROBE MICROANALYSIS INTRODUCTION Electron probe microanalysis (EPMA) is an analytical technique that has stood the test of time. Not only is EPMA able to trace its origins back to the discovery of X-rays at the end of the nineteenth century, but the first commercial instrument appeared over 50 years ago. Nevertheless, EPMA remains a widely used technique for determining the elemental composition of solid specimens, able to produce maps showing the distribution of elements over the surface of a specimen while also accurately measuring their concentrations.
    [Show full text]
  • Application of Laser-Induced Breakdown Spectroscopy to Forensic Science: Analysis of Paint Samples
    The author(s) shown below used Federal funds provided by the U.S. Department of Justice and prepared the following final report: Document Title: Application of Laser-Induced Breakdown Spectroscopy to Forensic Science: Analysis of Paint Samples Author: Michael E. Sigman, Ph.D., Erin M. McIntee, M.S., Candice Bridge, Ph.D. Document No.: 237839 Date Received: February 2012 Award Number: 2006-DN-BX-K251 This report has not been published by the U.S. Department of Justice. To provide better customer service, NCJRS has made this Federally- funded grant final report available electronically in addition to traditional paper copies. Opinions or points of view expressed are those of the author(s) and do not necessarily reflect the official position or policies of the U.S. Department of Justice. This document is a research report submitted to the U.S. Department of Justice. This report has not been published by the Department. Opinions or points of view expressed are those of the author(s) and do not necessarily reflect the official position or policies of the U.S. Department of Justice. FINAL TECHNICAL REPORT Application of Laser-Induced Breakdown Spectroscopy to Forensic Science: Analysis of Paint Samples Michael E. Sigman, Ph.D. (Principal Investigator) Erin M. McIntee, M.S. Candice Bridge, Ph.D. 1National Center for Forensic Science and Department of Chemistry, University of Central Florida, PO Box 162367, Orlando, FL 32816-2367 Award number 2006-DN-BX-K251 Office of Justice Programs National Institute of Justice Department of Justice Points of view in this document are those of the authors and do not necessarily represent the official position of the U.S.
    [Show full text]
  • The Electron Microprobe Laboratory at Arizona State University
    47th Lunar and Planetary Science Conference (2016) 3018.pdf THE ELECTRON MICROPROBE LABORATORY AT ARIZONA STATE UNIVERSITY. A. Wittmann1, D. Convey1, T. Sharp1, M. Wadhwa2, P. Buseck3, and K. Hodges4 1LeRoy Eyring Center for Solid State Science, Arizona State University, Box 871704, Tempe, AZ 85287-1704, [email protected]; 2Center for Meteorite Studies-School of Earth and Space Exploration, Arizona State University, Box 871404, Tempe, AZ 85287; 3School of Molecular Sciences, Arizona State University, Box 871604, Tempe, AZ 85287-1604; 4School of Earth and Space Exploration, Arizona State University, Box 876004, Tempe, AZ 85287-6004. Introduction: In 2011, Arizona State University For instrument control, we can utilize the custom- replaced their 25 year old electron microprobe with a ized JEOL system software and the PC-based Probe state-of-the-art JEOL JXA-8530F field emission in- for Windows software. strument. Our facility was partially funded by NASA Summary Analytical Capabilities: The electron and serves as an investigator facility instrument for microprobe laboratory at Arizona State University NASA’s Planetary Science Research Program. allows to determine the chemical composition of solid Technical Capacities: The JEOL JXA-8530F materials up to 10 cm in size that are stable under high HyperProbe is an electron microscope that has a nomi- vacuum. The non-destructive analytical technique does nal imaging resolution of 3 nm with a X-ray spectrom- not require special sample preparation and produces eter for non-destructive X-ray
    [Show full text]
  • Duncumb: Microprobe Design in the 1950S: Some Examples in Europe
    Microsc. Microanal. 7, 100–107, 2001 DOI: 10.1007/s100050010068 Microscopy AND Microanalysis © MICROSCOPY SOCIETY OF AMERICA 2001 Microprobe Design in the 1950s: Some Examples in Europe Peter Duncumb* Department of Earth Sciences, University of Cambridge, Downing Street, Cambridge CB2 3EQ, UK Abstract: The early days of the electron microprobe were characterized by the variety of designs emerging from different laboratories in Europe, the United States, and the USSR. Examples from Europe illustrate well the diverging trends in the evolutionary process at that time. Later, commercial pressures and a better understand- ing of user needs forced a rationalization on both sides of the Atlantic, to the point where only few variants have survived. These were memorable days, with scope for healthy rivalry and vigorous debate. Key words: electron microprobe, magnetic lens design, X-ray spectrometers, microprobe analysis, X-ray mi- croanalysis, instrument design INTRODUCTION Nearly all were represented at a memorable meeting in 1958 in Washington, DC, organized by LaVerne Birks of In this commemoration of 50 years of microprobe analysis, the Naval Research Laboratory, who was himself one of I shall look back to the first decade, before the technique the early pioneers in the US. became commercialized in the 1960s. Papers in this issue by 2. To show how the design of these instruments was influ- Jean Philibert, Kurt Heinrich, and others introduce the enced by the particular applications for which they were broad dimension, so I can concentrate on a relatively nar- intended, and by the interests and background of the row aspect of the history: the evolution of instrument de- designer.
    [Show full text]
  • Raman Microprobe in the Study of Iron Technique; and Steel* a New
    UDC 543.423.8 :535.374 Laser Raman Microprobe Technique; A New Analytical Tool in the Study of Iron and Steel* By Kimitaka SATO** Synopsis It may be said that such background has naturally In recentyears, the laser Raman microprobetechnique has attracted the led to the development of a new microbeam analysis attention of many researchers as a new analytical techniquefor local ap- method, called the laser Raman microprobe,s-11) to plication. This paper introducesthe principle, function andfeatures of the obtain the information about the chemical bonds or technique and discusses its applicability to the study of iron and steel, conformation of molecules in local areas. Attempts citing several examples of application. This technique is based on phe- were made to apply the laser Raman microprobe to nomenon,called the Roman scattering, which is caused when a sample is the analysis of defects in materials, inclusions in min- irradiated with a laser light focussed to the utmost. The advantage of erals, catalysts, samples for environmental control this techniqueover conventionalones is that it is capable of obtaining the information about chemical species and atomic groups of moleculesin local and biological samples. In 1978, the 6th Interna- areas (~ rcm) through point, line or image (Raman image of specific tional Conference on Raman Spectroscopy was held wavenumber) analysis. Although this technique has notyet been applied in Bangalore, India, a place noted in connection with widely in the study of iron and steel, the scope of its application will be Raman, in commemoration of the 50th anniversary greatly widenedas a powerful tool in the elucidation of local defects, such of the discovery of the Raman effect.12) At this con- as blisters,precibitates, inclusion'sand corrosionproducts.
    [Show full text]
  • Ion Microprobe Techniques and Analyses of Olivine and Low-Ca
    American Mineralogist, Volume 66, pages 526-546, l98l Ion microprobetechniques and analysesof olivine and low-ca pyroxene I. M. SreBrE, R. L. HnRvIc, I. D. HurcHEoN AND J. V. Snanu Department of Geophysical Sciences, (Iniversity of Chicago Chicago, Illinois 60637 Abstract Experimentalconditions for major, minor, and trace elementanalysis of olivine and low- Ca pyroxene are describedand analytical accuracy tested using suites of natural samples spanninga wide range of Mg/Fe. Special attention was given to sample cleanlinessto avoid contamination, instrumental vacuum to eliminate hydrides in the secondaryion spectrum,and samplepreparation to give good precisionin measuredintensities. Especially bothersome were molecular interferences in the secondaryion spectrumwhich were separatedfrom analytical peaksusing massresolu- tion (M/AM) over 3000.Careful analysisof the secondaryion spectrumallowed choiceof ei- ther high or low massresolution depending on the presenceof interferences.Lithium (0.005), F (l?), Na (0.01),Mg, Al (0.1),Si, P (5), K (0.05),Mn (0.1),Fe, and Co (l) were analyzedat low resolutionwith detectionlimits (ppm) in parentheses.Elements requiring high resolution includeCa (l), Sc (l), Ti (l), V (l), Cr (l) and Ni (5). The secondary-ionintensities for Mg and Si do not correlate linearly with composition whereasFe is nearly linear. The simple relation of the Mgl(Mg + Fe) ratio to the measured secondaryion ratio Mg*/(Mg* + Fe*) enabled major element determination to within +l mol% of forsterite or enstatitecontent. The yield of Mg and Fe secondaryions is a complex function of composition,and Mg*/Si* and Fe*/Si* are not simply related to atomic ratios in the target. To test accuracyof minor elementdetermination as a function of major elementvariation, secondary-ioniatensities were compared with compositionsbased on electron probe mea- surements.Some elements (Al, Cr, Ti, Mn) give a linear relationshipwith no obvious matrix eflect,but Ni, and possiblyCa and Co, definitely dependon the matrix.
    [Show full text]
  • Laser-Induced Breakdown Spectroscopy (LIBS) in Cultural Heritage Cite This: Anal
    Analytical Methods View Article Online AMC TECHNICAL BRIEFS View Journal | View Issue Laser-induced breakdown spectroscopy (LIBS) in cultural heritage Cite this: Anal. Methods,2019,11,5833 Analytical Methods Committee AMCTB No. 91 Received 18th September 2019 DOI: 10.1039/c9ay90147g www.rsc.org/methods Laser-induced breakdown spectroscopy This is primarily because of the lack, to obtain clean spectra, it is essential to (LIBS) is a versatile technique that provides date, of commercial instruments dedi- start measuring the plume emission aer nearly instant elemental analysis of materials, cated to heritage applications, but also in a short delay (typically 0.5–1 ms) with both in the laboratory and in the field. This is some instances, of its micro-destructive respect to the laser pulse. done by focusing a short laser pulse on the character. surface of the sample, or object, studied and analysing the resulting spectrum from the Instrumentation laser-induced plasma. LIBS has been How does LIBS work? employed in the analysis of archaeological In recent years, a variety of LIBS instru- and historical objects, monuments and works The fundamental principle underlying ments, both bench-top and portable, – of art for assessing the qualitative, semi- LIBS stems from the brief interaction have been introduced by manufacturers – quantitative and quantitative elemental just a few nanoseconds between for speci c applications such as content of materials such as pigments, a focused laser pulse and a target object. screening of on-site materials or indus- pottery, glass, stone, metals, minerals and This concentration of light both in space trial process monitoring.
    [Show full text]
  • Chemical Analysis of Thermoluminescent Colorless Topaz Crystal Using Laser-Induced Breakdown Spectroscopy
    minerals Article Chemical Analysis of Thermoluminescent Colorless Topaz Crystal Using Laser-Induced Breakdown Spectroscopy Shahab Ahmed Abbasi 1,* , Muhammad Rafique 1 , Taj Muhammad Khan 2,3 , Adnan Khan 1, Nasar Ahmad 1 , Mohammad Rashed Iqbal Faruque 4 , Mayeen Uddin Khandaker 5 , Pervaiz Ahmad 1 and Abdul Saboor 1 1 Department of Physics, University of Azad Jammu and Kashmir, Muzaffarbad 13100, Pakistan; mrafi[email protected] (M.R.); [email protected] (A.K.); [email protected] (N.A.); [email protected] (P.A.); [email protected] (A.S.) 2 National Institute of Lasers and Optronics (NILOP), P.O. Nilore, Islamabad 45650, Pakistan; [email protected] 3 School of Physics and CRANN, Trinity College Dublin, the University of Dublin, Dublin 2, Ireland 4 Space Science Centre, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia; [email protected] 5 Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, Bandar Sunway 47500, Selangor, Malaysia; [email protected] * Correspondence: [email protected] or [email protected]; Tel.: +92-3025420455 Abstract: We present results of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) and energy-dispersive X-ray (EDX) analysis of natural colorless topaz crystal of local Pakistani origin. Topaz plasma was produced in the ambient air using a nanosecond laser pulse of width 5 ns and wavelength 532 nm. For the purpose of detection of maximum possible constituent elements within the Topaz sample, the laser fluences were varied, ranging 19.6–37.6 J·cm−2 and optical emission from Citation: Abbasi, S.A.; Rafique, M.; the plasma was recorded within the spectral range of 250–870 nm.
    [Show full text]
  • Mev Ion-Beam Analysis
    Volume 93, Number 3, May-June 1988 Journal of Research of the National Bureau of Standards Accuracy in Trace Analysis Nuclear Methods MeVIon Beam Analysis 2. Advanced Analysis Techniques J. A. Cookson and T. W. Conlon The power of MeV ion beam analysis can be ex- tended in several ways: by the use of heavy ions, by Harwell Laboratory, UKAEA measuring more than one parameter of the interac- Oxfordshire OXiI ORA, UK tion process, and by the application of coincidence techniques. Some examples are given below. 1. Introduction The main techniques traditionally used in MeV 2.1 ERDA Ion Beam Analysis are Particle Induced X-ray The Elastic Recoil technique (ERDA) utilizes Emission (PIXE), Rutherford Backscattering fast heavy ions to produce recoil substrate atoms (RBS) and Nuclear Reaction Analysis (NRA), that are ejected from the substrate and can be sub- which, broadly speaking, utilize light (m <4) ions. sequently analyzed. In contrast to the light ion These techniques can also be applied in the chan- techniques that generally provide only one parame- neling mode to study the structural properties of ter (usually a particle or proton energy), both re- crystalline materials (such as foreign atom location, coil mass and recoil energy can be measured. radiation damage, and interface studies). The tech- ERDA is in routine use as a single parameter niques have the common feature that all are based technique, where an energy spectrum of all the on processes that occur spontaneously in the inter- ions recoiling from the specimen can be interpreted action of light ion beams with solids.
    [Show full text]