Numerical Differential Protection of 220/132KV, 250 MVA Auto Transformer Using Siemens Make Differential Relay 7UT612
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Chapter – 3 Electrical Protection System
CHAPTER – 3 ELECTRICAL PROTECTION SYSTEM 3.1 DESIGN CONSIDERATION Protection system adopted for securing protection and the protection scheme i.e. the coordinated arrangement of relays and accessories is discussed for the following elements of power system. i) Hydro Generators ii) Generator Transformers iii) H. V. Bus bars iv) Line Protection and Islanding Primary function of the protective system is to detect and isolate all failed or faulted components as quickly as possible, thereby minimizing the disruption to the remainder of the electric system. Accordingly the protection system should be dependable (operate when required), secure (not operate unnecessarily), selective (only the minimum number of devices should operate) and as fast as required. Without this primary requirement protection system would be largely ineffective and may even become liability. 3.1.1 Reliability of Protection Factors affecting reliability are as follows; i) Quality of relays ii) Component and circuits involved in fault clearance e.g. circuit breaker trip and control circuits, instrument transformers iii) Maintenance of protection equipment iv) Quality of maintenance operating staff Failure records indicate the following order of likelihood of relays failure, breaker, wiring, current transformers, voltage transformers and D C. battery. Accordingly local and remote back up arrangement are required to be provided. 3.1.2 Selectivity Selectivity is required to prevent unnecessary loss of plant and circuits. Protection should be provided in overlapping zones so that no part of the power system remains unprotected and faulty zone is disconnected and isolated. 3.1.3 Speed Factors affecting fault clearance time and speed of relay is as follows: i) Economic consideration ii) Selectivity iii) System stability iv) Equipment damage 3.1.4 Sensitivity Protection must be sufficiently sensitive to operate reliably under minimum fault conditions for a fault within its own zone while remaining stable under maximum load or through fault condition. -
INNOVATIVE NUMERICAL PROTECTION RELAY DESIGN on the BASIS of SAMPLED MEASURED VALUES for SMART GRIDS Christophe Ghafari
INNOVATIVE NUMERICAL PROTECTION RELAY DESIGN ON THE BASIS OF SAMPLED MEASURED VALUES FOR SMART GRIDS Christophe Ghafari To cite this version: Christophe Ghafari. INNOVATIVE NUMERICAL PROTECTION RELAY DESIGN ON THE BASIS OF SAMPLED MEASURED VALUES FOR SMART GRIDS. Electric power. Université Grenoble Alpes, 2016. English. tel-01570127 HAL Id: tel-01570127 https://hal.archives-ouvertes.fr/tel-01570127 Submitted on 28 Jul 2017 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. THÈSE Pour obtenir le grade de DOCTEUR DE LA COMMUNAUTÉ UNIVERSITÉ GRENOBLE ALPES Spécialité : Génie Électrique Arrêté ministériel : 7 août 2006 Présentée par Christophe GHAFARI Thèse dirigée par Nouredine HADJSAID et codirigée par Raphaël CAIRE et Bertrand RAISON préparée au sein du Laboratoire G2Elab dans l'École Doctorale EEATS Innovative Numerical Protection Relay Design on the basis of Sampled Measured Values for Smart Grids Thèse soutenue publiquement le 16 décembre 2016 , devant le jury composé de : M. Lars NORDSTROM Rapporteur, Professor, Royal Institute of Technology, Sweden M. Désiré Dauphin RASOLOMAMPIONONA Président, Professor, Warsaw University of Technology, Poland M. Peter CROSSLEY Examinateur, Professor, University of Manchester, United Kingdom M. Carlo Alberto NUCCI Examinateur, Professor, University of Bologna, Italy M. -
Innovative Numerical Protection Relay Design on the Basis of Sampled Measured Values for Smartgrids Christophe Ghafari
Innovative numerical protection relay design on the basis of sampled measured values for smartgrids Christophe Ghafari To cite this version: Christophe Ghafari. Innovative numerical protection relay design on the basis of sampled mea- sured values for smartgrids. Electric power. Université Grenoble Alpes, 2016. English. NNT : 2016GREAT113. tel-01819664 HAL Id: tel-01819664 https://tel.archives-ouvertes.fr/tel-01819664 Submitted on 20 Jun 2018 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. THÈSE Pour obtenir le grade de DOCTEUR DE L’UNIVERSITÉ GRENOBLE ALPES Spécialité : Génie Electrique Arrêté ministériel : 7 août 2006 Présentée par Christophe GHAFARI Thèse dirigée par Nouredine HADJSAID et co-encadrée par Raphaël CAIRE et Bertrand RAISON préparée au sein du G2ELab dans l'École Doctorale EEATS Innovative Numerical Protection Relay Design on the basis of Sampled Measured Values for Smart Grids Thèse soutenue publiquement le 16 Décembre 2016, devant le jury composé de M. Lars NORDSTROM Rapporteur, Professor, Royal Institute of Technology, Sweden M. Désiré Dauphin RASOLOMAMPIONONA Président, Professor, Warsaw University of Technology, Poland M. Peter CROSSLEY Examinateur, Professor, University of Manchester, United Kingdom M. Carlo Alberto NUCCI Examinateur, Professor, University of Bologna, Italy M. -
Experimental Study of Numerical Relay for Over-Current Protection in Solar Panel for Securing the Hydrogen Production
E3S Web of Conferences 61, 00005 (2018) https://doi.org/10.1051/e3sconf/2018610000 5 ICREN 2018 Experimental Study of Numerical Relay for Over-current Protection in Solar Panel for Securing the Hydrogen production. Chawki Ameur menad1,*, M. Bouchahdane2, and Rabah Gomri1 1University Frères Mentouri Constantine 1, Faculty of Sciences and Technology, Department of Génie Climatique, 25000 Constatine, Algeria 2Department of Power and control Institute of Electrical and Electronic Engineering, IGEE Boumerdes, Algeria Abstract.. Every electrical system in solar panel can fail during electrical faults. In this incidence, high fault current can occur. Such current must be interrupted by a protective system. The research was supported by experimental tests. In work conditions close to real, the numerical relay REF542plus was tested for both instantaneous and extremely inverse definite minimum time IDMT over-current protection functions with the help of CMC 365 injection and test equipment associated to Test Universe software. Protecting hybrid solar panels generating by different renewable energy sources for hydrogen production from over-current is very important for improving the energy efficiency in one hand, and securing the function in critical condition from damage of the solar cells in second hand. The contribution of this research is controlling the over-current in the solar panel for securing the continuation of the hydrogen production from renewable energy sources in short time. The obtained results allowed the observation of the relay’s behavior when subjected to certain faults; where the solar panel keeps producing the hydrogen. 1 INTRODUCTION Due to the impact of the safety in solar systems on the energy efficiency in critical situation, an experimental proposal research project was studied for understanding the most important problem which is the over-current in solar systems in Algerian Climate. -
Maintenance Manuals
1ZVN460100 – D Maintenance Manuals 1ZVN460100 – D 2 / 3 Table of contents 1 Maintenance............................................................................................................... 3 2 Trouble Shooting ....................................................................................................... 5 1ZVN460100-D 1. Maintenance: Subject Check Time period Remarks Year Month Insulating oil Dielectric strength 3 Moisture content 1 Neutralisation value 1 Interfacial surface tension 1 Water content 1 Sludge content 1 Gas analysis 1 Oil tightness Tank 3 Conservator 3 Cooling equipment 3 Piping 3 Bushings 3 Cable sealing ends 3 If applicable Cable boxes 3 If applicable Buchholz relay 3 Gate valves 3 Valves 3 Oil level Tank 1 Conservator 1 Bushings 1 Cable sealing ends 1 If applicable Cable boxes 1 If applicable Thermometer pockets 1 Venting devices Tank 1 Release vent screws until Cooling equipment 1 Oil emerges. Afterwards Intermediate piping 1 screw plugs tight Bushings 1 Piping 1 Buchholz relay 1 Cable sealing ends 1 If applicable Earthing devices All metal parts 1 Tank 1 Motors 1 Star points 1 If applicable Surge arresters 1 If applicable Control cabinet 1 Steal armoured cabling 1 Shut-off devices In position “service” As required See plan “Position of shut off devices” (if provided) Buchholz relay Direction of oil flow At erection Float 1 Contacts 1 Gas sampling device 1 If applicable Functional test 1 Dial-type thermometers Contact setting 1 See the Technical data Position of maximum pointer 1 Functional test 1 Current -
Loss of Mains (ROCOF)
Assessment of Risks Resulting from the Adjustment of ROCOF Based Loss of Mains Protection Settings Phase II Authors Dr Adam Dyśko Dimitrios Tzelepis Dr Campbell Booth This work was commissioned by the Energy Networks Association and prepared for the workgroup “Frequency changes during large system disturbances” (GC0079) October 2015 Institute for Energy and Environment Department of Electronic and Electrical Engineering University of Strathclyde Glasgow REF: ENA/LOM/TR/2015-001 Table of Contents Abbreviations and symbols ......................................................................................................................3 1 Executive Summary .........................................................................................................................4 2 Introduction .....................................................................................................................................6 2.1 Methodology ............................................................................................................................6 3 WP2 – Simulation based assessment of NDZ ..................................................................................8 3.1 Network modelling ...................................................................................................................8 3.2 DG Models and Controls ...........................................................................................................8 3.2.1 Synchronous Generator ....................................................................................................9 -
100 Years of Relay Protection, the Swedish ABB Relay History
100 years of relay protection, the Swedish ABB relay history By Bertil Lundqvist ABB Automation Products, Substation Automation Division (Sweden) INTRODUCTION The ABB relay protection and substation automation history goes back to the turn of the previous century. The first protection relay type TCB was developed in the early years of 1900. The first installation was made in 1905. By 1925, a remote controlled station was put into operation. ABB has delivered many millions protection and control devices throughout the world. Through the years ABB has introduced a great number of leading innovations within the protection and control field. The development was from the beginning made with a national perspective, but very early a global perspective was introduced when designing relay and control equipment. The development can be divided in three main stages; the first stage was the era of electromechanical relays, which started over 100 years ago. The next era was static or electronic relays, which were introduced in the 1960s. The present era with microprocessor based relays started in the beginning of the 1980s, where microprocessor performed the logics, but the filtering was analogue. The first fully numerical relay was introduced 1986. 1. GENERAL • 1940 Harmonic restraint transformer- The technological history in Protection and Station differential Automation can be shown comparing space requirements between modern and old equipment. One • 1950 Compensator poly-phase distance relay numerical terminal can replace up two five panels with -
Protection Relay Testing and Commissioning
Protection Relay Testing and Commissioning Course No: E06-004 Credit: 6 PDH Velimir Lackovic, Char. Eng. Continuing Education and Development, Inc. 22 Stonewall Court Woodcliff Lake, NJ 07677 P: (877) 322-5800 [email protected] PROTECTION RELAY TESTING AND COMMISSIONING The testing and verification of protection devices and arrangements introduces a number of issues. This happens because the main function of protection devices is related to operation under fault conditions so these devices cannot be tested under normal operating conditions. This problem is worsened by the growing complexity of protection arrangements, application of protection relays with extensive software functionalities, and frequently used Ethernet peer-to-peer logic. The testing and verification of relay protection devices can be divided into four groups: - Routine factory production tests - Type tests - Commissioning tests - Occasional maintenance tests TYPE TESTS Type tests are needed to prove that a protection relay meets the claimed specification and follows all relevant standards. Since the basic function of a protection relay is to correctly function under abnormal power conditions, it is crucial that the operation is evaluated under such conditions. Therefore, complex type tests simulating the working conditions are completed at the manufacturer's facilities during equipment development and certification. The standards that cover majority of relay performance aspects are IEC 60255 and IEEE C37.90. Nevertheless, compliance may also include consideration of the demands of IEC 61000, 60068 and 60529, while products intended for installation in the EU also have to comply with the requirements of EU Directives. Since type testing of a digital or numerical protection relay includes software and hardware testing, the type testing procedure is very complex and more challenging than a static or electromechanical relay. -
Busbar Differential Protection / 7SS52 SIPROTEC 7SS52 Distributed Numerical Busbar and Breaker Failure Protection
Busbar Differential Protection / 7SS52 SIPROTEC 7SS52 distributed numerical busbar and breaker failure protection Function overview Busbar protection functions 1 • Busbar differential protection • Selective zone tripping • Very short tripping time (<15 ms) 2 • Extreme stability against external fault, short saturation-free time (≥ 2 ms) • Phase-segregated measuring systems • Integrated check zone 3 • 48 bays can be confi gured • 12 busbar sections can be protected • Bay-selective intertripping 4 Breaker failure protection functions LSP2392-afpen.tif • Breaker failure protection (single-phase with/without current) • 5 operation modes, selectable per bay 5 • Separate parameterization possible for busbar and line faults Fig. 9/1 SIPROTEC 7SS52 busbar protection system • Independently settable delay times for 6 all operation modes • 2-stage operation bay trip repeat/trip busbar Description • Intertrip facility (via teleprotection interface) The SIPROTEC 7SS52 numerical protection is a selective, reliable • “Low-current” mode using the circuit-breaker auxiliary contacts 7 and fast protection for busbar faults and breaker failure in medium, high and extra-high voltage substations with various Additional protection functions possible busbar confi gurations. • End-fault protection with intertrip or bus zone trip The protection is suitable for all switchgear types with iron-core • Backup overcurrent protection per bay unit (defi nite-time or 8 or linearized current transformers. The short tripping time is inverse-time) especially advantageous for applications with high fault levels or • Independent breaker failure protection per bay unit where fast fault clearance is required for power system stability. Features 9 The modular hardware allows the protection to be optimally matched to the busbar confi guration. The decentralized arrange- • Distributed or centralized installation ment allows the cabling costs in the substation to be drastically • Easy expansion capability reduced. -
Performance Assessment of Advanced Digital Measurement and Protection Systems
PSERC Performance Assessment of Advanced Digital Measurement and Protection Systems Final Project Report Part II Power Systems Engineering Research Center A National Science Foundation Industry/University Cooperative Research Center since 1996 Power Systems Engineering Research Center Performance Assessment of Advanced Digital Measurement and Protection Systems Final Report for PSERC Project T-22 Part II Lead Investigator: Mladen Kezunovic Graduate Students: Levi Portillo Bogdan Naodovic Texas A&M University PSERC Publication 06-22 July 2006 Information about this project For information about this project contact: Mladen Kezunovic, Ph.D. Texas A&M University Department of Electrical Engineering College Station, TX 77843 Tel: 979-845-7509 Fax: 979-845-9887 Email: [email protected] Power Systems Engineering Research Center This is a project report from the Power Systems Engineering Research Center (PSERC). PSERC is a multi-university center conducting research on challenges facing a restructuring electric power industry and educating the next generation of power engineers. More information about PSERC can be found at the Center’s website: http://www.pserc.org. For additional information, contact: Power Systems Engineering Research Center Arizona State University Department of Electrical Engineering Ira A. Fulton School of Engineering Phone: (480) 965-1879 Fax: (480) 965-0745 Notice Concerning Copyright Material PSERC members are given permission to copy without fee all or part of this publication for internal use if appropriate attribution -
Research Paper Engineering Optimal Location of Phasor Measurement Unit for Complete Network Observability of Power Systemt
Volume : 2 | Issue : 3 | March 2013 • ISSN No 2277 - 8160 Research Paper Engineering Optimal Location of Phasor Measurement Unit for Complete Network Observability of Power Systemt Mudassir A Maniar Electrical Engineerig Department L D College of Engineering Navrangpura Ahmedabad Ashfaq M Qureshi Electrical Engineerig Department L D College of Engineering Navrangpura Ahmedabad Dr. Bhavik N Suthar Electrical Engineerig Department L D College of Engineering Navrangpura Ahmedabad This paper presents analytical method to find optimal location of PMU to make power system observable. This Optimal ABSTRACT PMU Placement (OPP) is optimization problem which has been solved using BILP (Binary Integer Linear Programming). The analytical method has been coded in the MATLAB and applied to different IEEE test systems up to 118 buses. Moreover OPP is offline optimization problem. The method has also been implemented for certain contingent conditions like line outage and PMU failures. The number of PMUs required is almost one third of system buses however their numbers actually depends on the topology of the network. KEYWORDS: PMU, OPP, BILP, IEEE-test system I-INTRODUCTION However PMU are costlier technology as fiber optics communica- The various Electrical Power supply system operating all across tion along with GPS is required. Thus OPP is optimization problem the world are larger and most complex control systems which which could be solved using either analytical or heuristic meth- are constantly monitored and controlled centrally through EMCs ods. (Energy Management Centers. The Voltage Magnitude along with Phasor angle of all the connected nodes (buses) of the III- OPP PROBLEM FORMATION power system network are state variables of any power system. -
Power Transformer Protection
Power Transformer Protection Course No: E06-003 Credit: 6 PDH Velimir Lackovic, Char. Eng. Continuing Education and Development, Inc. 22 Stonewall Court Woodcliff Lake, NJ 07677 P: (877) 322-5800 [email protected] POWER TRANSFORMER PROTECTION The advancement of electrical power systems has been reflected in the developments in power transformer manufacturing. This has led to a wide range of power transformers. Their ratings range from a few kVA to several hundred MVA and are used for a wide variety of applications. Power transformer protection varies with the application and transformer importance. In the case of a fault within the power transformer it is important to minimize tripping time in order to decrease the impact of thermal stress and electrodynamic forces. Distribution power transformers can be protected by using fuses or overcurrent protection relays. This leads to time-delayed protection due to downstream co-ordination requirements. Nevertheless, time delayed short circuit clearance is unacceptable on larger power transformers due to system operation/stability and cost of repair. Power transformer short circuits are typically grouped into five categories: - Winding and terminal short circuits - Core short circuits - Tank and transformer accessory short circuits - On–load tap changer short circuits - Prolonged or uncleared external short circuits Summary of short circuit causes initiated in the power transformer itself, is shown in Figure 1. Winding and Terminal Core Tank and Accessories OLTC Figure 1. Power transformer short circuit statistics TRANSFORMER WINDING FAULTS A transformer winding fault is limited in magnitude by the following factors: - source impedance - neutral grounding impedance - winding connection arrangement - fault voltage - power transformer leakage reactance Few distinct cases come up and are described below.