Addendum No. 1 Bid No. 729-20 City Hall Renovation

Total Page:16

File Type:pdf, Size:1020Kb

Addendum No. 1 Bid No. 729-20 City Hall Renovation ADDENDUM NO. 1 BID NO. 729-20 CITY HALL RENOVATION & MODERNIZATION This addendum forms a part of the contract documents for the above identified project and modifies the original specifications, plans, and contract documents as noted below. Those portions of the contract not specifically mentioned in this addendum remain in force. All trades affected shall be fully advised of these changes, deletions, or additions. Substitute pages reflecting changes in the specifications are attached. SPECIFICATIONS ITEM NO. 1 PART D Technical Specifications 10810 Toilet Accessories. Replace with Technical Specification 10810 Toilet Accessories dated May 5, 2021. ITEM NO. 2 PART D Technical Specifications 16010 Low Voltage. Replace with Technical Specification 16010 Low Voltage dated May 5, 2021. ITEM NO. 3 Low Voltage Plans for Audio Video, Data, and Security Packages dated April 22, 2021 shall be added and included in the Bid Plans dated April 19, 2021. _________________________05/05/21______ Michael C. Livingston Date Capital Manager – Capital Engineering City of Lancaster BIDDER'S CERTIFICATE BID NO. 729-20 CITY HALL RENOVATION & MODERNIZATION I acknowledge receipt of Addendum No. 1 and accept the aforementioned conditions. Date Contractor THIS ADDENDUM TO BE NOTED ON PAGE F-2 AND THIS SHEET IS TO BE ATTACHED TO SHEET F-18 AND TURNED IN WITH THE CONTRACTOR'S BID TO THE CITY. ADDENDUM #1 SECTION 10810 TOILET ACCESSORIES 1.00 GENERAL 1.01 SUMMARY A. Principal work in this Section: Contractor installation of Owner furnished. 1. Toilet room accessories. 2. Supplementary parts and components, such as inserts, clips, anchors, fasteners, and other miscellaneous supports required for a complete installation. B. Related work: 1. Cut-outs, openings and recesses for installation of accessories. 2. Supports for toilet room accessories: Reference Section 06100. 1.02 SUBMITTALS A. Data: Manufacturer’s catalog cuts and data sheets, complete parts list, and installation requirements for each accessory specified. B. Closeout: With closeout submittals furnish to the Owner operating instructions and keys for equipment and locks. 1.03 QUALITY ASSURANCE A. The Drawings and these Specifications are based on accessories made by Georgia Pacific. The Owner will furnish accessories through separate contract for installation by contractor under this contract. B. Compliance with ADA requirements for accessories and their attachments is the Contractor’s responsibility. 1.04 HANDLING A. Procedure: In compliance with manufacturer’s requirements. B. Protection: Keep protective covers on accessories until their installation is complete, then remove at final clean-up. 1.05 WARRANTY A. Provide the Owner the manufacturer warranty protecting mirrors against silver spoilage for 5 years after Substantial Completion. CITY HALL TENANT IMPROVEMENT AND MODERNIZATION TOILET ACCESSORIES CITY OF LANCASTER 10810-1 SOLICITATION NO. 1TB 729-20 1.06 COMPLIANCE WITH DISABLED ACCESS LAWS A. Accessories and other items specified herein and hardware provisions therefore shall comply with current requirements for access for the disabled, in the California Building Code. B. Toilet accessories required to be accessible shall be mounted at heights according to CBC, Section 1115B.8. Toilet paper and feminine napkin dispensers located on the grab bar side of an accessible toilet room or stall shall not project more that 3 inches from the finished wall surface nor be located closer than 1-1/2 inch clear of the tangent point of the grab bar. C. Regulatory Requirements: Toilet Accessories required to be accessible shall be mounted at heights according to CBC Section 1115B.8. The grab bar can not project more than 3 inches into the 48” minimum clear space in front of the water closet CBC Section 1115B.4.3. The accessory shall not be located closer than 1 ½” clear of the tangent point of the grab bar. 2.00 PRODUCTS 2.01 MATERIALS A. Stainless steel: AISI Type 302/304 complying with ASTM A 167. B. Sheet steel: 1. Cold-rolled commercial quality, complying with ASTM A 336, 20 gage minimum. 2. Galvanized steel: ASTM A 527, G 60 zinc coating, 20 gage minimum. C. Mirrors: 1/4 inch “Silvering Quality” float glass with silver coating, copper protective coating and 2 mil thick protective paint; complying with CS 27. D. Mounting devices: Galvanized steel. E. Fasteners: Stainless steel where exposed; may be galvanized steel where concealed. Provide spanner head design where exposed. 2.02 FABRICATION A. Fabricate units with seamless one piece flanges on exposed faces. 1. Miter corners, weld and grind smooth and flush with parent metal so that welds are invisible on exposed surfaces. 2. Open joints (not fully welded) on exposed surfaces are not acceptable. 3. Conceal anchoring devices. B. Hang doors or panels on continuous stainless steel piano hinges. CITY HALL TENANT IMPROVEMENT AND MODERNIZATION TOILET ACCESSORIES CITY OF LANCASTER 10810-2 SOLICITATION NO. 1TB 729-20 C. Master-key locked dispensing units. Key coin boxes of coin-operated dispensing units separately from the lock on the unit. D. Grind smooth all edges, both inside and out. E. Finish exposed surfaces with an AISI No. 4 finish running in the same direction (horizontal or vertical) for all accessories, except where a knurled surface is specified for grab bars. 3.00 EXECUTION 3.01 INSPECTION A. Inspect adjacent construction and supports. B. Make sure that openings are within allowable tolerances, plumb, level, clean, will provide a solid anchoring surface, and that other conditions detrimental to the proper or timely completion of this work are corrected before proceeding with installation. 3.02 INSTALLATION A. Drill holes to correct size and location. Install accessories plumb, level and equally spaced (when applicable). B. Attach accessories securely with screws or bolts to steel studs or backing plates. Do not use molly or toggle bolts in gypsum board. C. Adjust accessories for proper operation. After completion of installation, clean and polish exposed surfaces after removal of protective coverings. 3.03 ACCESSORY SCHEDULE Owner will furnish for Contractor installation at a minimum the following accessories. When drawings indicate a greater number of accessories, Owner will furnish for Contractor installation quantities as indicated in drawings. A. Surface mounted Georgia Pacific toilet paper dispenser Provide one (1) each standard WC stall. C. Accessible Restroom Georgia Pacific semi recessed toilet paper Provide one (1) each accessories WC. F. Surface mounted Georgia Pacific soap dispenser Provide not less than one (1) for each pair of lavatories. CITY HALL TENANT IMPROVEMENT AND MODERNIZATION TOILET ACCESSORIES CITY OF LANCASTER 10810-3 SOLICITATION NO. 1TB 729-20 G. Surface mounted Georgia Pacific toilet seat cover dispenser Provide one (1) each WC. I. Surface mounted Georgia Pacific sanitary napkin/ $0.25 release tampon dispenser (Staff) Provide one (1) each at Women’s restroom. J. Surface mounted Georgia Pacific Soap dispenser Provide one (1) at each sink. M. Hand Dryer Xlerator Model XL-SB in ADA compliant recess kit Provide as indicated on plans Electric hand dryer is contractor provided item. CITY HALL TENANT IMPROVEMENT AND MODERNIZATION TOILET ACCESSORIES CITY OF LANCASTER 10810-4 SOLICITATION NO. 1TB 729-20 Improving Hygiene Can Make Restrooms Safer for All Solutions to help reduce risk and increase facility safety RESTROOM A Coordinated Suite of Hygienic Solutions Delivering Performance, Intuitive Design and Elegance. 70% 85% 80% 97% of people say having of consumers say of facility managers of enMotion® customers enMotion® paper towel an unclean public agree that having a are satisfied. systems improves their restroom is a coordinated set of Source: CPT-18-1741 perception of public reflection of the dispensers from the restrooms. overall cleanliness same manufacturer of the entire upgrades the look of Source: CPT-18-1829 establishment. their restrooms. Source: GP PRO Proprietary Source: GP PRO Proprietary Research: CSP-16-024 Research: PRO-16-200 2017 Dispensers enMotion® Automated Touchless Soap & enMotion® Flex Paper Towel System Sanitizer System A roll is always on stand-by From the brand that delivers a Welcome to a new age of zero waste and jam-free design. 97% customer satisfaction rating* Introducing GP PRO’s enMotion® Flex Paper Towel System. Rich, moisturizing foam soap for your patrons. Its Dual Roll Auto-Switch Technology consumes the Single-handed loading for your janitorial staff. Portion smallest roll first, and allows for 100% utilization of each roll controlled dispensing for your waste reduction goals. before it switches to the roll on stand-by. That means ZERO waste. The intuitive design of the enMotion Flex dispenser makes it easy to train staff—and helps make refilling easy. HYGIENIC Automated touchless dispensing and sealed hygienic refills help reduce risk of cross-contamination. HYGIENIC Touchless, motion-activated dispensing promotes EASY TO MAINTAIN better hand hygiene and helps prevent contamination. Long lasting, intuitively designed, one-handed refills with front loading access help provide nearly EFFICIENCY effortless maintenance and uninterrupted service. From the brand that delivers 99% jam-free dispensing. Auto-feed grabs and guides towels. HIGH CAPACITY enMotion® Counter Mount dispensers deliver DEPENDABILITY over 2500 dispenses and enMotion® Gen2 Soap Auto-switching rolls virtually wipe out jams and run- dispensers deliver up to 3000 dispenses per bottle. outs and make users happy with a towel every time. *Source: GP PRO Proprietary Research: CPT-18-1741 TM TM TM *Fits on Compact® Dispensers Compact® Coreless Toilet Paper System ActiveAire® Freshener Dispensing System High capacity meets low maintenance Solutions that tackle even the The Compact® Coreless Toilet Paper System is flexible and toughest odor space saving with long-lasting rolls. The sleek, modern Freshness where you need it most—in the stall. A first- design supports the high standards of your facility. of-its-kind air freshener that stops odor at the source. Motion-sensing for an automatic burst of freshness, plus scent on-demand with a wave of the hand. HYGIENIC Lock mechanism helps prevent contamination.
Recommended publications
  • Plumbing Guidelines for ADA Accessibility
    Plumbing Guidelines for ADA Accessibility Course No: M01-004 Credit: 1 PDH Steven Liescheidt, P.E., CCS, CCPR Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 [email protected] Appendix A to Part 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities U.S. Architectural and Transportation Barriers Compliance Board (Access Board) 1331 F Street, N.W., Suite 1000 Washington, D.C. 20004-1111 (202) 272-0080 (202) 272-0082 TTY (202) 272-0081 FAX 4.16 Water Closets. mm) that allows a person in a wheelchair to make 4.16.1 General. Accessible water closets shall a parallel approach to the unit (see Fig. 27(c) and comply with 4.16.2 through 4.16.6. (d)). This clear floor space shall comply with 4.2.4. EXCEPTION: Water closets used primarily by children ages 12 and younger shall be permitted 4.16 Water Closets. to comply with 4.16.7. Fig. 27 Drinking Fountains and Water Coolers 45 4.17 Toilet Stalls. 4.16.2 Clear Floor Space. Clear floor space for bar centerline. The grab bar behind the water water closets not in stalls shall comply with Fig. closet shall be 36 in (915 mm) minimum. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach. EXCEPTION: If administrative authorities require flush controls for flush valves to be located in a 4.16.3* Height.
    [Show full text]
  • New Seibu Limited Express Train 001 Series Laview Harmonized with Both Urban and Natural Surroundings
    FEATURED ARTICLES Advanced Railway Systems through Digital Technology New Seibu Limited Express Train 001 Series Laview Harmonized with both Urban and Natural Surroundings The development of Seibu Railway Co., Ltd.’s new limited express 001 series started out of the necessity to replace the older New Red Arrow Seibu 10000 Series. This coin- cided with the 100th anniversary of the company’s Ikebukuro Line, which runs between Ikebukuro Station and Hanno Station, leading to the decision to adopt a new flagship train that would mark the beginning of the company’s second century. Seibu Railway decided to go in a new direction in the development of this limited express train, entrust- ing its design to world-renowned architect Kazuyo Sejima, and including Hitachi to handle manufacturing of the rolling stock in a three-way project. This article describes the development of the new limited express Laview through this project, together with the key features that emphasize the power of its design. Naoji Ueki Yasunori Tanii Naotoshi Inoue Hidenori Yagi Yuta Kawaguchi 1. Introduction 2. Overview of the 001 Series Recent years have seen the development of many types 2. 1 of rolling stock that emphasize their visual designs. Seibu Design Concept Railway Co., Ltd.’s latest limited express 001 series Laview is the successor to the New Red Arrow 10000 Series. It Th e year 2015, when development work began on the 001 features a spherical front, a silver body that blends into the series, was the 100th anniversary of the opening of the scenery, large windows to enjoy a panoramic view, and an Ikebukuro Line of Seibu Railway, linking Ikebukuro Station interior in which passengers can feel at home.
    [Show full text]
  • ADA Design Guide Washrooms & Showers
    ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories Interactive version available at bradleycorp.com/ADAguide.pdf Accessible Stall Design There are many dimensions to consider when designing an accessible bathroom stall. Distances should allow for common usage by people with a limited range of motion. A Dimension guidelines when dispensers protrude from the wall in toilet rooms and 36" max A toilet compartments. 915 mm Anything that a person might need to reach 24" min should be a maximum of 48" (1220 mm) off of 610 mm the finished floor. Toilet tissue needs to be easily within arm’s 12" min reach. The outlet of a tissue dispenser must 305 mm be between 24" (610 mm) minimum and 42" (1070 mm) maximum from the back wall, and per the ANSI standard, at least 24" min 48" max 18" above the finished floor. The ADA guide 610 mm 1220 mm defines “easily with arm’s reach” as being within 7-9" (180–230 mm) from the front of 42" max the bowl and at least 15" (380 mm) above 1070 mm the finished floor (48" (1220 mm) maximum). Door latches or other operable parts cannot 7"–9" 18" min 180–230 mm require tight grasping, pinching, or twisting of 455 mm the wrist. They must be operable with one hand, using less than five pounds of pressure. CL Dimensions for grab bars. B B 39"–41" Grab Bars need to be mounted lower for 990–1040 mm better leverage (33-36" (840–915 mm) high). 54" min 1370 mm 18" min Horizontal side wall grab bars need to be 12" max 455 mm 42" (1065 mm) minimum length.
    [Show full text]
  • Making Rail Accessible: Guide to Policies and Practices
    Network Rail Making Rail Accessible: Guide to Policies and Practices November 2017 0 Operator’s Strategy Across our managed stations, Network Rail will consider accessibility issues and plan how we meet disabled people’s needs. To provide continuity Network Rail will aim to standardise the services and environment we offer across all of our stations To help us do this Network Rail has formed the Built Environment Accessibility Panel (Network Rail BEAP) who assist Network Rail, to deliver a better railway for a better Britain. The BEAP members provide technical and experiential advice on the design and management of Network Rail built environment proposals and plans. We endorse and will adopt the standards and guidance in the Code of Practice for Accessible Train Station Design (the code) and in the Persons with Reduced Mobility, Technical Specification for Interoperability. We will meet all of the code’s standards for new, renewed or enhanced facilities at our stations. Where this is not possible we will seek other options as soon as possible. Only when these have been exhausted will we seek dispensation and consider suitable alternatives. We have close working relationships with Train Operating Companies (TOCs) who operate train services from our managed stations. As the station operator, we will coordinate management arrangements at stations for TOCs, including assisting disabled passengers. Management Arrangements Providing services to disabled people is an integral part of how we deliver rail services. We integrate the policies and practices outlines in this document fully into our day-to-day activities. We have set up managed station project teams to develop, modernise and maintain stations without compromising their historical importance.
    [Show full text]
  • Keys to Compliance Assembly and Mercantile
    KEYS TO COMPLIANCE 4 to 4.8 perimeter : Grab bars are required to be at a height of 33 to 100 – 120 36 inches. A117.1 and 2010 Standards measure to the top of the graspable surface. Graphics in ADAAG and earlier editions of A117.1 showed this measurement 1¼ – 2 2 max to the center of the bar. 32 – 51 51 : It is critical that the distance between the bar and wall does not exceed 1½ inches. If the gap is , reproduced with permission larger, the arm of a wheelchair user might slip into ® the gap during the transfer. Of similar importance © ICC is the 1¼-inch to 2-inch maximum diameter (1½-inch maximum in ADAAG) required for circular grab bars. Figure 16 Handrail cross section {505.7} : : Noncircular grab bars are permitted to provide a New to the 2003 edition of A117.1 is a vertical grab 2-inch cross section dimension and a 4.8-inch maxi- bar required to be located 39 to 41 inches from the mum perimeter (Figure 16). wall behind the water closet and 39 to 41 inches above the fl oor. IBC 1109 ASSEMBLY AND MERCANTILE OCCUPANCIES Code Points Assembly and Mercantile Occupancies [ In assembly and mercantile occupancies (or portions IBC/A117.1 2010 Standards ADAAG of assembly and mercantile occupancies), where an aggregate of six (6) or more men’s and women’s water IBC 1109.2.1 N/A N/A closets are required, the IBC ® requires an additional IBC 1109.2.1.4 unisex (family) toilet room. This additional accessible Delmar/Cengage Learning toilet room cannot be located more than 500 feet away from or more than one fl oor above or below public toilet rooms.
    [Show full text]
  • GEB3194 ADA Whitepaper.Indd
    Overcoming Accessibility Design Challenges in the Restroom with In-Wall Technology Public restrooms are one of the most critical building amenities or after March 15, 2012 must comply with the 2010 ADA Standards. because they need to be responsive to a wide range of human needs There are potential penalties for non-compliance. Beyond delaying a and address people with an equally wide range of abilities. The needs Certificate of Occupancy, for example, non-compliant facilities that of a person using a wheelchair – and the space a wheelchair requires are found to be in violation of the ADA standard can incur steep fines – are used as a primary source of design information for making public and even be targeted in lawsuits by the Department of Justice (DOJ)1. restrooms accessible to address these needs. Amount of space and paths of travel for wheelchairs and the fixed nature of the plumbing There are two basic toilet-compartment designs that are covered in equipment impose finite requirements and limits on design. the standards: (1) the Ambulatory Accessible Toilet Compartment and (2) the Wheelchair Accessible Toilet Compartment. The Ambulatory However, environments built with accessible design benefit a wide Accessible Toilet Compartment provision supports the needs of range of users beyond those with special needs, including: individuals who are ambulatory and may require the use of a cane, walker, or crutches. Specifically, the Ambulatory Accessible Toilet • People with stability and balance issues Compartment (see Figure 1) needs a depth of 60 inches (1525 mm) • Children and people of different heights minimum, with 2009 ICC/ANSI Standards retaining the 36 inches • People of different weights (915 mm) absolute width dimension (the 2010 ADA Standards allow a • People with temporary health problems, such as broken bones or range of 35 inches (890 mm) to 37 inches (940 mm) maximum width).
    [Show full text]
  • General Brochure
    AE Portable Service Deodorizers Toilet Additional Toilets Units Trailers Products “Each day 473,000,000 litres of water are saved around the world because people use portable toilets rather than a flushing toilet.” HISTORY TABLE OF CONTENTS HISTORY ........................................................ 2 ABOUT US .................................................... 3 ROI REWARDS .............................................. 3 2019 Opening of our Italian office and warehouse 2018 Acquisition of Polyportables PORTABLE TOILETS .................................... 4 Doubled the space again in Germany Moved to a much bigger warehouse in the UK Tufway ....................................................... 4 2016 Launch of the revisited Maxim 3000 Mondo ....................................................... 5 2015 Move of the German distribution centre and tripled the space Axxis .......................................................... 6 2014 Opening of our new Central Distribution Center in Bristol, US Launch of the toilet trailers product line in USA Maxim 3000 ............................................... 7 2012 Freedom 3: New ADA compliant wheelchair toilet Liberty ....................................................... 8 Breeze II: hand sanitiser station New warehouse in South Africa Freedom .................................................... 9 2010 Highrise: unit for high rise building construction Sanibone: hand sanitiser stand Highrise ................................................... 10 ABOUT US Mains Connect ........................................
    [Show full text]
  • General Requirements for Toilet & Bathing
    City Of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES General (CBC 11B-213) Where toilet and bathing facilities are provided, EACH toilet and bathing room shall be accessible to persons with disabilities (comply with Section 11B-603) and shall be on an accessible route connected to an accessible entry. Exception: 1. Where toilet and bathing facilities are provided in buildings without a ramp or elevators above and below the first floor permitted by Section 11B-206.2.3 Exception 1, accessible toilet and bathing facilities shall be provided on a story connected by an accessible route to an accessible entrance. 2. In alterations where it is technically infeasible to comply with Section 11B-603, altering existing toilet or bathing room shall not be required where a single accessible unisex toilet room or bathing room is provided and located in the same area and on the same floor as existing inaccessible toilet or bathing rooms. (CBC 11B-213.2 Exception 1) Where existing toilet rooms or bathing rooms are not accessible (do not comply with Section 11B-603), directional signs indicating the location of the nearest accessible toilet room or bathing room within the facilities shall be provided. (CBC 11B-216.8) Unisex Facilities When is a unisex toilet room allowed? (CPC 422.2 Exceptions): 1. In occupancies with a total occupant load of 10 or less, including customers and employees. 2. In business and mercantile occupancies with a total occupant load of 50 or less including customers and employees.
    [Show full text]
  • Toilet Rooms Based on the 2010 ADA Standards for Accessible Design
    The ADA Checklist for Existing Facilities Priority 3 - Toilet Rooms Based on the 2010 ADA Standards for Accessible Design Project Building Location Date Surveyors Contact Information When toilet rooms are open to the public they should be accessible to people with disabilities. Institute for Human Centered Design ADA National Network www.HumanCenteredDesign.org Questions on the ADA 800-949-4232 voice/tty Copyright © 2016 www.ADAchecklist.org ADA Checklist for Existing Facilities Priority 3 – Toilet Rooms This checklist was produced by the New England ADA Center, a project of the Institute for Human Centered Design and a member of the ADA National Network. This checklist was developed under a grant from the Department of Education, NIDRR grant number H133A060092-09A. However the contents do not necessarily represent the policy of the Department of Education, and you should not assume endorsement by the Federal Government. Questions or comments on the checklist contact the New England ADA Center at 617-695-0085 voice/tty or [email protected] For the full set of checklists, including the checklists for recreation facilities visit www.ADAchecklist.org. Copyright © 2016 ADA Checklist for Existing Materials. You can freely reproduce and distribute this content. Include proper attribution. But you must get permission before using this content as a fee-based product. Institute for Human Centered Design www.ADAchecklist.org Priority 3 – Toilet Rooms © 2016 Page 2 ADA Checklist for Existing Facilities Priority 3 – Toilet Rooms Priority 3 – Toilet Rooms Comments Possible Solutions 3.1 If toilet rooms are available to • Reconfigure toilet rooms Yes No the public, is at least one toilet • Combine toilet rooms to room accessible? (Either one create one unisex for each sex, or one unisex.) accessible toilet room • Note: If toilet rooms are chiefly for children, e.g., in elementary schools and day care centers, use the children’s specifications in Toilets - 604.1, 604.8, 604.9, 609.4 and Lavatories and Sinks – 606.2.
    [Show full text]
  • Fostering the Shopping Malls Accessibility to Encourage the Sustainable Tourism
    Fostering the Shopping Malls Accessibility to Encourage the Sustainable Tourism Nurul Sukma Lestari and Rachel Dyah Wiastuti Hotel Management Department, Faculty of Economics & Communication, Bina Nusantara University, Jakarta, Indonesia 11480 Keywords: Accessibility, Accessible, Accessible Tourism, Sustainable Tourism, Shopping Mall Abstract: Shopping has emerged as one of the biggest expenditures in the tourism industry. Shopping malls represent the main shopping site for an urban destination such as Jakarta. Moreover, the destination should continuously provide not only a diverse place to shop, but also a convenience and accessible place for all to sustain the tourism value. The aim of this study is to determine the shopping malls accessibility based on UNWTO Accessible Tourism concept as a part of sustainable tourism. Data were gathered from direct field observation and interview from January to June 2018. Jakarta Tourism Board official website was employed as references to aside eight Jakarta shopping malls as research objects. The findings refine the shopping malls accessibility based on six categories; parking area, signage, elevators, public telephones, public toilets and pricing. The results reveal good compliance for pricing in term of no rising fee for the visitor with special requirements. However, the public telephone is hardly found and a limited number of public toilets for children and disabled are available. Therefore, this study contributes to providing added value information for tourism destination to advance the shopping experience for tourist and visitor by constructing the shopping malls for everyone. 1 INTRODUCTION do tourist activities independently and with equity and dignity (UNWTO, 2016). Tourism is comprised of a wide range of activity such People with special needs or people with as shopping (Choi, et al., 2016), that can be the main disability are a huge potential to become travelers and activity in Urban Tourism.
    [Show full text]
  • ILLINOIS Accessibility Code Site Inspection Checklist Attorney General
    ILLINOIS Accessibility Code Site Inspection Checklist Attorney General INDEX HOW TO DO A SITE INSPECTION ............................................... 1 ILLINOIS ACCESSIBILITY CODE Parking ............................................................................. 2 Walks and Sidewalks ...................................................... 3 Curb Ramps .................................................................... 4 Pedestrian Ramps ........................................................... 5 Entrances ......................................................................... 6 Doors and Doorways ...................................................... 6 Corridors and Aisles ....................................................... 7 Passenger Elevators ........................................................ 8 Restrooms ......................................................................10 Water Fountains .............................................................16 Public Telephones .......................................................... 17 Controls, Light Switches and Alarms ........................... 18 Signs and Identification ................................................. 18 Warning Signs and Hazards ......................................... 19 Seating, Tables and Work Surfaces ..............................19 Additional Requirements ............................................... 20 II HOW TO DO A SITE INSPECTION You will need the following materials to complete a site inspection: A) A tape measure; B) An accessibility
    [Show full text]
  • CHECKLIST C ACCESSIBLE TOILETS CHECKLIST These
    CHECKLIST C ACCESSIBLE TOILETS CHECKLIST These guidelines relate to accessible toilets for use by visitors. Different considerations may apply where accessible toilets are to be used by employees. All dimensions are derived from “Inclusive Mobility – a Guide to Best Practice on Access to Pedestrian and Transport Infrastructure” (2002) written by Philip R Oxley (Cranfield Centre for Logistics and Transportation) for the Mobility and Inclusivity Unit of the Department of Transport. These measurements themselves are largely based on BS 8300 “Design of buildings and their approaches to meet the needs of disabled people – Code of Practice”. Feature Requirement Explanatory notes Space for your notes Location Ideally the toilet should be placed near to the meeting rooms, and certainly on the same floor as the principal meeting rooms. Type of toilet Ideally the toilets should be independent unisex toilets, not integrated with male and female toilets. This allows a disabled person to be accompanied by a person of the opposite sex. Size of cubicle In new buildings, the size will be governed by the BS 8300 recommends a minimum Part M Approved Document. size of 2.2 m x 1.5 m. In existing buildings the availability of space will govern the size of the cubicle. Signage Where the accessible toilet is not placed immediately adjacent to the male and female toilets, a sign is needed to direct visitors to the accessible toilet. Door Minimum opening – 925 mm. No door closer should be fitted. The door should stay open until the disabled person closes it behind him or her. The door must be capable of opening outwards.
    [Show full text]