Etude Diagnostique Du Réseau D'approvisionnement En Eau
Total Page:16
File Type:pdf, Size:1020Kb
ETUDE DIAGNOSTIQUE DU SYSTEME D’ALIMENTATION EN EAU POTABLE DE LA VILLE DE SABOU AU BURKINA FASO. MEMOIRE POUR L’OBTENTION DU MASTER EN INGENIERIE DE L’EAU ET DE L’ENVIRONNEMENT : OPTION : INFRASTRUCTURES ET RESEAUX HYDRAULIQUES ------------------------------------------------------------------ Présenté et soutenu publiquement le 29 Septembre 2018 par Pêgd-wendé Stanislas OUIYA Travaux dirigés par : Mr Moussa OUEDRAOGO Enseignant à l’Institut International de l’Eau et de l’Environnement Mr Jean François SANDWIDI « Ingénieur Hydraulicien chef de section RPE à l’ONEA » Jury d’évaluation du stage : Président : Dr. Angelbert BIAOU Membres : Dr. Harinaivo Anderson ANDRIANISA Dr. Lawani MOUNIROU Mr. Amadou BOUREIMA Mr. Boukary SAWADOGO Mr. Moussa OUEDRAOGO Promotion [2016/2017] Institut International d’Ingénierie Rue de la Science - 01 BP 594 - Ouagadougou 01 - BURKINA FASO Tél. : (+226) 50. 49. 28. 00 - Fax : (+226) 50. 49. 28. 01 - Mail : [email protected] - www.2ie-edu.org Etude diagnostique du système d’approvisionnement en eau potable de la commune rurale de Sabou Dédicace Je dédie ce travail A mes parents ; A mes frères et sœurs ; Et à ceux qui ont contribué de près ou de loin à la réussite de ce travail. Merci Seigneur pour toutes ces grâces renouvelées. Pêgd-wendé Stanislas OUIYA GCH/IRH Promotion 2016-2017 2 Etude diagnostique du système d’approvisionnement en eau potable de la commune rurale de Sabou Remerciements Au terme de ce travail, nous tenons à témoigner notre profonde gratitude à toutes les personnes qui de loin ou de près ont contribué à l’élaboration de ce mémoire. Je remercie particulièrement : – Monsieur Moussa OUEDRAOGO, pour nous avoir consacré son temps à l’encadrement de ce mémoire ; – Monsieur Jean François SANDWIDI, pour nous avoir donné l’opportunité de travailler sur ce thème ; – Mes encadreurs à l’ONEA, à savoir les membres de la section RPE pour leur entière disponibilité ; – Monsieur Mohamed Lamine CISSE chef du service SIG/DRNO ; – Monsieur Moumouni KABORE le chef du centre de Sabou et son personnel qui n’ont ménagé aucun effort pour nous faciliter le travail sur les informations sur le réseau ; – Enfin mes camarades et les amis pour les moments de joie, de solidarité et de fraternité ; Pêgd-wendé Stanislas OUIYA GCH/IRH Promotion 2016-2017 3 Etude diagnostique du système d’approvisionnement en eau potable de la commune rurale de Sabou RESUME Dans les années 1980, Sabou, ville située sur la route nationale N°1 (entre Ouagadougou-Bobo) abritait deux (02) forages exploités exclusivement pour l’alimentation de la marre aux caïmans. Pour des soucis d’amélioration des conditions de vie de la population de Sabou, ces ouvrages de captage ont connu des renforcements au niveau du stockage et des conduites pour devenir un réseau d’approvisionnement en eau potable. Ainsi, la capacité du réservoir est passée de 50 m3 à 100 m3 avec des longueurs de conduite estimées à plus de 25km. Ayant une valeur cible de 95%, le rendement du réseau d’eau potable de Sabou oscille entre 63 et 70% depuis près de 5 ans malgré les multiples investigations. Il est donc impératif pour l’Office National de l’Eau et de l’Assainissement de trouver des solutions dans l’urgence pour la résolution de cette insuffisance. C’est dans ce contexte que nous avons effectué le diagnostic pour déceler les difficultés liées au mauvais rendement. Pour y parvenir, il a été question de faire des analyses des rapports d’exploitation existant et de les comparer aux mesures effectuées sur le terrain. En effet, ces mesures ont porté sur les outils de comptage pour l’évaluation de leurs états de fonctionnement. A cela s’ajoute des observations sur les nœuds des raccordements des différents forages. Il a été relevé plusieurs anomalies hydrauliques notamment un sur-comptage au niveau des compteurs avec un taux d’erreur de plus de 45%, un débit nul sur les forages F5 et F6 et de mauvais raccordements sur différents nœuds. Pour pallier à ces dysfonctionnements précédemment cités, nous avons proposé un remplacement des compteurs défectueux, une diagraphie des forages et un remplacement des tés au niveau des nœuds. La mise en œuvre de ces dispositions selon le plan d’actions proposé permettra d’améliorer le rendement fixé par l’Office National de l’Eau et de l’Assainissement. Mots clés : 1 - Sabou 2 - AEP 3 -Réseau 4 - Diagnostic 5 - Diagraphie Pêgd-wendé Stanislas OUIYA GCH/IRH Promotion 2016-2017 4 Etude diagnostique du système d’approvisionnement en eau potable de la commune rurale de Sabou ABSTRACT In the 1980s, Sabou, a city located on the No.1 national road (between Ouagadougou- Bobo) had two (02) boreholes operated exclusively for the supply of lacke to the caimans. For the sake of improving the living conditions of the population of Sabou, these catchment works have been reinforced storage and pipes to become a drinking water supply network. Thus, the capacity of the tank has increased from 50 m3 to 100 m3 with pipeq lengths estimated at more than 25km. With a target value of 95%, the performance of the Sabou drinking water network has oscillated between 63 and 70% for nearly 5 years despite multiple investigations. It is therefore imperative that the National Office of Water and Sanitation find urgent solutions to address this gap. It is in this context that we made the diagnosis to identify the difficulties related to poor performance. To achieve this, there has been discussion of analyzing existing exploitation reports and comparing them with measurements made in the field. Indeed, these measures focused on the counting tools for the evaluation of their operating states. Added to this are observations on the nodes of the connections of the various drillings. Several hydraulic anomalies have been noted, including counter-counting with an error rate of more than 45%, zero flow on the F5 and F6 boreholes and poor connections on different nodes. To overcome the aforementioned dysfunctions, we proposed a replacement of the defective meters, a logging of the boreholes and a replacement of the ‘’té’’ at the nodes. The implementation of its provisions will improve the performance set by the National Office for Water and Sanitation. Keywords: 1 - Sabou 2 - AEP 3 - Network 4 - Diagnosis 5 - Logging Pêgd-wendé Stanislas OUIYA GCH/IRH Promotion 2016-2017 5 Etude diagnostique du système d’approvisionnement en eau potable de la commune rurale de Sabou LISTE DES ABREVIATIONS AEP : Approvisionnement en Eau Potable BF : Borne Fontaine BNDT : Base Nationale de Données Topographiques BP : Branchement Particulier DRNO : Direction Régionale du Nord-Ouest F3 : Forage n°3 F4 : Forage n°4 F5 : Forage n°5 F6 : Forage n°6 F7 : Forage n°7 IGB : Institut Géographique du Burkina OMD : Objectif du Millénaire pour le Développement ONEA : Office National de l’Eau et de l’Assainissement PAGIRE : Plan d'Action pour la Gestion Intégrée des Ressources en Eau PN AEPA : Programme National d’Approvisionnement en Eau Potable et d’Assainissement PVC : Polychlorure de Vinyle RGPH : Recensement General de Population et de l’Habitation SIG : Système d’Information Géographique SCADD : Stratégie de Croissance Accélérée pour le Développement Durable 2iE : Institut International d’ingénierie de l’Eau et de l’Environnement Pêgd-wendé Stanislas OUIYA GCH/IRH Promotion 2016-2017 6 Etude diagnostique du système d’approvisionnement en eau potable de la commune rurale de Sabou Table des matières I. Introduction. .................................................................................................................... 11 II. Problématique .................................................................................................................. 12 III. Objectifs du travail ...................................................................................................... 13 III.1. Objectif général ..................................................................................................................... 13 III.2. Objectifs spécifiques .............................................................................................................. 13 IV. Présentation de la structure d’accueil ........................................................................ 14 IV.1 Généralités sur l’ONEA ......................................................................................................... 14 IV.2 Organisation et missions de l’ONEA .................................................................................... 14 IV.2.1. Organisation. ....................................................................................................................... 14 IV.2.2. Missions ............................................................................................................................... 15 IV.3. Section Réduction des pertes en Eau ................................................................................... 15 V. Matériels et Méthodes ..................................................................................................... 16 V.1.Présentation de la zone d’étude .............................................................................................. 16 V.1.1 Situation géographique de la localité ................................................................................... 16 V.1.2. Climat .................................................................................................................................... 17 V.1.3. Cadre socio-économique et démographique .....................................................................