Asus Z017d Hw: 1.3

Total Page:16

File Type:pdf, Size:1020Kb

Asus Z017d Hw: 1.3 Reference: MT160429C27_R01 Partial Report on EN301511/EN301908-2/EN301908-13 Report on ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Report Reference: Project : MT160429C27_R01 Date: June 13, 2016 Test Laboratory: Bureau Veritas ADT Hwa Ya Lab & Head Office No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil, Kwei Shan Dist, Taoyuan, 33383, Taiwan (R.O.C) Note: Phone: 886-3-318-3232 Fax:886-3-211-5834 URL: www.bureauveritas-adt.com Page 1 of 28 Reference: MT160429C27_R01 1Administrative Data 1.1 Project Data Project Responsible: Steven Yeh Date Of Test Report: 2016/06/13 Date of first test: 2016/05/17 Date of last test: 2016/06/07 1.2 Applicant Data Company Name: ASUSTek COMPUTER INC. Address: 6F, No. 15, LI-TE Rd., PEITOU, TAIPEI 112, TAIWAN Contact Person: Adam1 Huang Phone: +886-2-2894 3447 #1063 Fax: +886-2-2894 3447 E-Mail: [email protected] 1.3 Test Laboratory Data The following list shows all places and laboratories involved for test result generation: Bureau Veritas ADT Company Name : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hwa Ya Lab & Head Office Street : No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, City : 333 Taoyuan Country : Taiwan Contact Person : Mr. Elio Sun Phone : 886-3-318-3232 ext. 1880 Fax : 886-3-211-5834 E Mail : [email protected] Laboratory Details Lab ID Identification Responsible Lab 1 TP005 - RF - R&S Lucas Chen TS8950GW Lab 2 TP006 - RSE Test Eric SW Chiu System 1 Lab 3 TP036 – RF - Keysight - Jason Ho GS-8800 Lab 4 TP057 - RF - Anritsu Rocco Wu ME7873F Lab 5 TP104 - RF - Anritsu Brian Fan ME7873L (BV TW) Lab 6 TP104 - RF - Anritsu Rock Tseng ME7873L (BV SZ) Lab 16 TP098 - RF - R&S Brandon Ryu TS8980 (BV Korea) Page 2 of 28 Reference: MT160429C27_R01 1.4 Signature of the Testing Responsible Nilson She responsible for tests performed in: Lab 1, Lab 2, Lab 3, Lab 4, Lab 5, Lab 6 2 Test Object Data 2.1 General OUT Description The following section lists all OUTs (Object's Under Test) involved during testing. OUT: ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Low Voltage 3.60 V High Voltage 4.40 V Nominal Voltage 3.85 V Low Temp -10 °C High Temp 55 °C Nominal Temp 25 °C Manufacturer Company Name : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hwa Ya Lab & Head Office Street : No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, City : 333 Taoyuan Country : Taiwan Contact Person : Mr. Elio Sun Phone : 886-3-318-3232 ext. 1880 Fax : 886-3-211-5834 E Mail : [email protected] 2.2 Detailed Description of OUT Samples Sample : 01.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 358973070044629 358973070044637 Date of Receipt 2016/5/10 Page 3 of 28 Reference: MT160429C27_R01 Sample : 02.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 358973070044629 358973070044637 Date of Receipt 2016/5/10 Sample : 03.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 359027070040787 359027070040795 Date of Receipt 2016/5/10 Sample : 04.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 359027070041041 359027070041058 Date of Receipt 2016/5/10 Sample : 05.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 359027070040027 359027070040035 Date of Receipt 2016/5/10 Sample : 06.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 359027070040688 359027070040696 Date of Receipt 2016/5/10 Sample : 07.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 358973070044603 358973070044611 Date of Receipt 2016/5/30 Sample : 08.01.01 OUT Identifier ASUS_Z017D HW: 1.3 SW: 13.16.0.14 Sample Description IMEI: 0 0 Date of Receipt 2016/5/30 Page 4 of 28 Reference: MT160429C27_R01 2.3 Setups used for Testing For each setup a relation is given to determine if and which samples and auxiliary equipment is used. The left side list all OUT samples and the right side lists all auxiliary equipment for the given setup. Setup No. List of OUT samples List of auxiliary equipment Sample No. Sample Description AE No. AE Description 01.01.01 IMEI: 358973070044629/ 358973070044637 02.01.01 IMEI: 358973070041948/ 358973070041955 03.01.01 IMEI: 359027070040787/ 359027070040795 04.01.01 IMEI: 359027070041041/ 359027070041058 05.01.01 IMEI: 359027070040027/ 359027070040035 06.01.01 IMEI: 359027070040688/ 359027070040696 07.01.01 IMEI: 358973070044603/ 358973070044611 08.01.01 IMEI: N/A 3 Results 3.1 General Documentation of tested Available at the test laboratory. devices: Interpretation of the The results of the inspection are described on the following test results: pages, where 'Conformity' or 'Passed' means that the certification criteria were verified and that the tested device is conform to the applied standard. In cases where 'Declaration' is printed, the required documents are available in the manufacturers product documentation. In cases where 'not applicable' is printed, the test case requirements are not relevant to the specific equipment implementation. 3.2 List of the Applicable Body Designation Description R&TTE - EN 301 511 (900/1800) V9.0.2 Official R&TTE version based on the latest OJ publication and EN 301 511 R&TTE - EN 301 908-2 V6.2.1 Official R&TTE version based on the latest OJ publication R&TTE - EN 301 908-13 V6.2.1 Official R&TTE version based on the latest OJ publication Page 5 of 28 Reference: MT160429C27_R01 3.3 List of Test Specification Test Specification: 3GPP TS 51.010-1 Date / Version 2016/03/21 Version: 13.0.0 Title: 3GPP TS 51.010-1 Description: Part 1: Conformance specification Test Specification: 3GPP TS 34.121-1 Date / Version 2016/03/21 Version: 12.3.0 Title: 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; User Equipment (UE) conformance specification; Radio transmission and reception (FDD); Description: Part 1: Conformance specification Test Specification: 3GPP TS 36.521-1 Date / Version 2016/04/01 Version: 13.1.0 Title: 3rd Generation Partnership Project; Evolved Universal Terrestrial Radio Access (E-UTRA); User Equipment (UE) conformance specification Radio transmission and reception Page 6 of 28 Reference: MT160429C27_R01 4 Annex 4.1 Additional Information for OUT Feature The calibration, hardware and software states are shown for the testing period. Page 7 of 28 Reference: MT160429C27_R01 4.2 Additional Information for Test Equiment The calibration, hardware and software states are shown for the testing period. Test Equipment Agilent N1960A (GS-8800) Lab ID: Lab 3 Manufacturer: Agilent Technologies Description: N1960A (RF Conformance Test System GS-8800) Type: GS-8800 Single Devices for Agilent N1960A (GS-8800) Single Device Name Type Serial Number Manufacturer BASEBAND BASEBAND PROCESSOR-DUAL TX ANTE 0140 Anite PROCESSOR-DUAL TX ANTENNA Climatic Chamber ITH-120-45-CP-AR IAA1207-006 Giant Control PC Control PC TBNB110348 Agilent Technologies EPM Series Power Meter N1914A MY52180044 Agilent Technologies Calibration Details Last Execution Next Exec. Calibration 2014/08/28 2016/08/28 HW/SW Status Date of Start Date of End FW:A2.01.05 2012/04/24 ESG VECTOR SIGNAL E4438C 250KHz-3GHz MY49072580 Agilent Technologies GENERATOR Calibration Details Last Execution Next Exec. Calibration 2014/05/26 2016/05/26 HW/SW Status Date of Start Date of End FW:C.05.83 2012/04/24 FADER ADAPTOR UNIT FADER ADAPTOR UNIT 0024 Anite GS8800 Plus 2 Test Set N8990A P06 MY45500169 Agilent Technologies GSM Module N1960-80104 MY46410114 Agilent Technologies Mobile Communications 66319D MY43007492 Agilent Technologies DC Source Calibration Details Last Execution Next Exec. Calibration 2015/08/19 2016/08/18 HW/SW Status Date of Start Date of End FW:A03.01 2012/04/24 MXA Signal Analyzer N9020A MY52090163 Agilent Technologies Calibration Details Last Execution Next Exec. Calibration 2014/05/27 2016/05/27 HW/SW Status Date of Start Date of End FW:A08.03 2012/04/24 PSG Analog Signal E8257D 250KHz-20GHz MY51111397 Agilent Technologies Generator Calibration Details Last Execution Next Exec. Calibration 2014/05/27 2016/05/27 HW/SW Status Date of Start Date of End FW: C.06.10 2011/03/01 Page 8 of 28 Reference: MT160429C27_R01 Single Devices for Agilent N1960A (GS-8800) (continued) Single Device Name Type Serial Number Manufacturer RF Interface N1960-80103 MY45490235 Agilent Technologies SHEAR ACCELEROMETER PCB/J353B34 153748 Giant Universal Switch Control N9370A MY46130241 Agilent Technologies Unit HW/SW Status Date of Start Date of End FW: A03.03 2012/04/24 VIBRATION CONTROLLERECON/VT-9002 193220704 Giant WIRELESS CHANNEL SR5500 WCE350F5 Spirent Communications EMULATOR Calibration Details Last Execution Next Exec. Calibration 2015/07/08 2016/07/07 HW/SW Status Date of Start Date of End FW:03.50.03 2012/04/24 WIRELESS "8960 SERIES 10 MY50267377 Agilent Technologies COMMUNICATIONS TEST E5515C" SET Calibration Details Last Execution Next Exec. Calibration 2014/11/12 2016/11/12 HW/SW Status Date of Start Date of End FW: H.01.12 2012/04/24 Page 9 of 28 Reference: MT160429C27_R01 Test Equipment Anritsu ME7873 WCDMA RF Test System Lab ID: Lab 6 Manufacturer: ANRITSU COMPANY,INC Description: Anritsu ME7873 WCDMA RF Test System Type: ME7873 Single Devices for Anritsu ME7873 WCDMA RF Test System Single Device Name Type Serial Number Manufacturer CONTROL PC ( LTE) Latitude E6530 00371-OEM-899267 1-00 Fading Sumulator MF6900A 6201469067 Anritsu Calibration Details Last Execution Next Exec.
Recommended publications
  • Agilent Technologies E5904B Option 300 Trace Port Analyzer for ARM7-ETM and ARM9-ETM Microprocessors Data Sheet
    Agilent Technologies E5904B Option 300 Trace Port Analyzer for ARM7-ETM and ARM9-ETM Microprocessors Data Sheet • Single box with both trace port • Support for a variety of and emulation interfaces to the ETM implementations CPU core • 200 MHz operation • Real-time debug of ASICs with • Self powered ARM7 or ARM9 cores • Trigger in/out for use with • Support for ARM’s Real Time Trace another Agilent logic analyzer (RTT) and Real Time Monitor (RTM) or oscilloscope Complete System Analysis Agilent’s trace port analyzer links this data to the debugger The E5904B is an integrated software, which interprets the JTAG emulator and Trace Port trace data and reconstructs the Analyzer (TPA). This tool instruction code flow. This tool supports ARM’s Real Time Trace provides a cost-effective, (RTT) and Real Time Monitor nonintrusive, real-time view Figure 1. Agilent E5904B option 300 trace (RTM) for full speed real-time of code execution. It is not port analyzer for ARM7 and ARM9. system debug of ASICs with the necessary to run any special ARM7 or ARM9 cores and the ARM debug code on the target. Embedded Trace Macrocell (ETM). Quickly and accurately determine Because the information on the root cause of your team’s The self-powered Agilent trace code execution is broadcast most difficult hardware and port analyzer is compatible with from inside the microprocessor, software integration problems low power and battery-powered real-time execution trace is with Agilent Technologies’ applications. available even when the powerful trace port analysis and instruction cache is enabled or JTAG emulation.
    [Show full text]
  • Agilent B1500A Semiconductor Device Analyzer
    Agilent B1500A Semiconductor Device Analyzer User’s Guide Agilent Technologies Notices © Agilent Technologies 2005, 2006, 2007 Warranty defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive No part of this manual may be reproduced in The material contained in this docu- no greater than Limited Rights as defined in any form or by any means (including elec- ment is provided “as is,” and is sub- FAR 52.227-14 (June 1987) or DFAR tronic storage and retrieval or translation ject to being changed, without notice, into a foreign language) without prior agree- 252.227-7015 (b)(2) (November 1995), as in future editions. Further, to the max- applicable in any technical data. ment and written consent from Agilent imum extent permitted by applicable Technologies, Inc. as governed by United law, Agilent disclaims all warranties, States and international copyright laws. either express or implied, with regard to this manual and any information Manual Part Number contained herein, including but not B1500-90000 limited to the implied warranties of merchantability and fitness for a par- Edition ticular purpose. Agilent shall not be liable for errors or for incidental or Edition 1, July 2005 consequential damages in connec- Edition 2, December 2005 tion with the furnishing, use, or per- Edition 3, April 2006 formance of this document or of any Edition 4, January 2007 information contained herein. Should Edition 5, June 2007 Agilent and the user have a separate Edition 6, November 2007 written agreement with warranty terms covering the material in this document that conflict with these Agilent Technologies, Inc.
    [Show full text]
  • PCI Express SIG Compliance Overview for Lattice Semiconductor Fpgas
    PCI Express SIG Compliance Overview for Lattice Semiconductor FPGAs August 2007 Technical Note TN1166 Introduction The PCI Express compliance testing is offered by the PCI Special Interest Group (PCI SIG). The Compliance Workshop Program offers standardized device testing and comprehensive criteria for PCI Express systems, peripherals, and components. The program provides FPGA manufacturers the opportunity to test a SERDES- based FPGA and the needed Intellectual Property (IP) on a compliant add-in card with other members’ PCI Express products. This forum allows for the delivery of devices and IP that are compliant with PCI Express stan- dards. Successful completion of PCI Express compliance testing provides our customers with a level of confidence when using Lattice’s FPGAs to build PCI Express solutions. It assists FPGA designers to achieve interoperability while minimizing risk and reducing time to market in designs that use complex, high performance PCI Express interfaces with Lattice FPGAs. The PCI SIG Compliance Program, which is open to all members of the PCI SIG, is a voluntary compliance pro- gram. Testing is completed to insure devices meet the PCI SIG specifications and provides a vehicle to test with many other manufacturers of PCI Express products. The goal is to promote the development of high-quality prod- ucts that offer reliable and hassle-free operation. Device manufacturers use the PCI SIG as a means to ultimately be included on the PCI SIG Integrators List. Prod- ucts that implement PCI SIG technologies and are referenced on the Integrators List show that they fulfill the strin- gent requirements and will provide a robust solution.
    [Show full text]
  • Customer Faqs As We Transition to Keysight Technologies
    Customer-viewable FAQ – July 2014 Agilent Technologies, Inc. 5301 Stevens Creek Blvd. Santa Clara, CA 95051 Customer FAQs as We Transition to Keysight Technologies Statement to Customers: We expect to begin operating as Keysight Technologies, August 1, 2014. We will launch our company as the largest test and measurement supplier that can offer world-class technology and market-leading test platforms. Because Keysight will be 100% focused on electronic measurement, it means that the top opportunities in electronic measurement are our company’s top opportunities. With this focus, we are transforming our product portfolio to anticipate your changing needs, beginning with solutions in wireless communications test, modular, and software. You will see us become even more aggressive in being first to market with leading edge solutions to help you succeed. Both Agilent and Keysight are committed to partnering with you in providing the same service and support during and after our transition. Below are detailed Q&As to help you better understand our plans. If you have additional questions not answered here, please contact your local Agilent Customer Contact Center. Customer FAQs: (Browse by category or search using Ctrl + F) Contracts Service/support Customer experience Strategy/policy Orders/quotes Customer-viewable FAQ – July 2014 Contracts 1. What will happen to existing purchase, service and support agreements? Purchase, service and support agreements will be assigned to Keysight effective August 1. We are committed to creating a seamless transition and continuing to deliver the excellent service and support you expect. 2. What will happen to Agilent software licensing entitlement? Will existing customers need to re-register or sign a new agreement? Agilent Electronic Measurement software license agreements and software subscription service agreements remain intact.
    [Show full text]
  • Milestones and Personalities in Science and Technology
    History of Science Stories and anecdotes about famous – and not-so-famous – milestones and personalities in science and technology BUILDING BETTER SCIENCE AGILENT AND YOU For teaching purpose only December 19, 2016 © Agilent Technologies, Inc. 2016 1 Agilent Technologies is committed to the educational community and is willing to provide access to company-owned material contained herein. This slide set is created by Agilent Technologies. The usage of the slides is limited to teaching purpose only. These materials and the information contained herein are accepted “as is” and Agilent makes no representations or warranties of any kind with respect to the materials and disclaims any responsibility for them as may be used or reproduced by you. Agilent will not be liable for any damages resulting from or in connection with your use, copying or disclosure of the materials contained herein. You agree to indemnify and hold Agilent harmless for any claims incurred by Agilent as a result of your use or reproduction of these materials. In case pictures, sketches or drawings should be used for any other purpose please contact Agilent Technologies a priori. For teaching purpose only December 19, 2016 © Agilent Technologies, Inc. 2016 2 Table of Contents The Father of Modern Chemistry The Man Who Discovered Vitamin C Tags: Antoine-Laurent de Lavoisier, chemical nomenclature Tags: Albert Szent-Györgyi, L-ascorbic acid He Discovered an Entire Area of the Periodic Table The Discovery of Insulin Tags: Sir William Ramsay, noble gas Tags: Frederick Banting,
    [Show full text]
  • Agilent ASMS History
    The (Brief) History of Mass Spectrometry at Agilent Technologies Courtney Milner, Bryan Millar, Bill Russ, John Fjeldsted and Carl Myerholtz ASMS 2019 Agilent, Santa Clara CA The Start First Mass Spectrometers Taking MS to the Masses Expanding Technologies Routine, Reliable and Robust for Every Analysis 1938 - Hewlett – Packard 1971 - 5930A GC/MS System 1977 – 1992 Floor Standing Systems Evolution 1984 – 1996 GC/MSD for all. 1997 – 2003 New Benchtop LC MS Technologies 2006 – 2009 New MS Technologies and Shrinking The story of Mass Spectrometry at Agilent The first mass spectrometer introduced was the Shortly after the introduction of the 5992A benchtop Development of the MSD concept continued, with To complete the portfolio of benchtop MS technologies, Products Technologies starts with the founding of Hewlett- 5930A GC/MS system, which included an integrated GC/MS system in 1977 the 5985 floor standing model important advances in instrument control with new PC HP developed a benchtop single quadrupole LC/MS Agilent continued to invest in the development of new Packard in 1938 by two class of 1934 Stanford oscilloscope for tuning and a strip chart recorder. The gave the user greater flexibility and performance with an technologies and software to make the systems easier to system, including the new Patented orthogonal technologies designed to offer users a mass graduates Bill Hewlett and David Packard. They MS featured a dodecapole arrangement and offered a easily interchangeable EI / CI Ion source, and the ability to use for a greater group of scientists. 1990 saw the electrospray source2. This system was followed in 2000 spectrometer that would continue to take the technique started the business part time in the garage at 367 mass range upto m/z 650.
    [Show full text]
  • Here People Can Belong When They Travel by Being Connected to Local Cultures and Having Unique Travel Experiences
    ... for the implementation of sound, long-term tax policies that promote the global competitiveness of the U.S. high technology industry. Background The Silicon Valley Tax Directors Group is composed of representatives from leading high-technology companies with corporate offices predominantly located in the area between San Francisco and San Jose, California (widely known as the “Silicon Valley”). The group was formed in 1981 with current members representing the following companies: Organization Representative Autodesk SVTDG Co-Chair: Kirsten Nordlof; VP, Tax, Treasury, Risk and Procurement Cisco Systems, Inc. SVTDG Co-Chair: Robert F. Johnson; Sr. VP, Global Tax and Customs Dolby Laboratories, Inc. SVTDG Co-Chair: Grace L. Chu; Vice President, Tax and Treasurer Accenture N. James Shachoy; Senior Managing Director, Global Tax Activision Blizzard, Inc. Alex Biegert; Senior Vice President, Tax Advanced Micro Devices, Inc. Steven Kurt Johnson; Senior Director, Head of Tax Agilent Technologies, Inc. Stephen A. Bonovich; Vice President, Tax Airbnb, Inc. Mirei Yasumatsu; Global Head of Tax Amazon, Inc. Kurt Lamp; Vice President | Global Tax Analog Devices Tom Cribben; Global Tax Director Ancestry.com Edward R. Gwynn; Vice President of Tax Apple Inc. Phillip Bullock; Senior Director of Taxes Applied Materials Steven K. Shee; Vice President - Tax Aptiv, PLC Tim Seitz; Vice President Tax, Trade & Government Affairs Arista Networks Inc Jennifer A. Raney; Head Of Global Tax & Treasury Atlassian Anthony J. Maggiore; Global Head of Tax Bio-Rad Laboratories Kris L. Fisher; Vice President, Global Tax BMC Software, Inc. Matt Howell; Vice President, Global Tax Broadcom Limited Ivy Pong; Vice President, Global Taxation Cadence Design Systems, Inc.
    [Show full text]
  • Agilent Technologies' Spin­ Make It Acceptable for Printing'?" with Any Employees
    FROM THE EDITOR can't say exactly when I became meeting to talk ""ith customers or a big fan of CEO Lew Platt, but visitors-and ended up staying I think it was one day in Febru­ longer than either of you imagined ary 1993. he would. He cares deeply about. I had written a MEASURE article the personal tonch. about HP's order-fulfillment problems. For the past few years, Lew has A couple of senior executives felt the gotten into the habit of eating lunch (one was too honest. Lew was asked with several of us from HP Communi­ to arbitrate the dispute. In many cations. I think he enjoyed the fact companies, that would have been that we rarely talk about work. an easy decision: senior executives 1, Name a topic-sports, current events, employee publication O. fine wine, photography, literature, Lew walked over to my office and wombats-and Lew invmiably explained-almost apologetically­ knows more about it than anyone On the cover: Carly Fiorina, that the article had some problems at the table. HP's new president and and needed to be pulled from the Here's a guy who regularly coun­ CEO, sets a fast and ener· getic pace for the company magazine, which was due to go to the sels and dines with CEOs, world lead­ to follow. Retiring President printer within a few days. I countered, ers and royalty; yet, he seems equally and CEO Lew Platt is non­ "You mean there's no middle ground? happy eating chicken strips and fries executive chairman of the HP Board while overseeing There's no way to edit the story to in the company cafeteria and t.alking Agilent Technologies' spin­ make it acceptable for printing'?" with any employees.
    [Show full text]
  • ISO 9001 Certificate
    CERTIFICATE The Certification Body of TÜV SÜD AMERICA INC. hereby certifies that Agilent Technologies, Inc. 5301 Stevens Creek Boulevard Santa Clara, CA 95051 USA (see pages 2-15 for additional locations) Has implemented a Quality Management System in accordance with: ISO 9001:2015 The scope of this Quality Management System includes: Design, Development, Manufacture and Support of Analytical Instrumentation Systems, Automation Systems, Vacuum Products and Polymer Systems for Clinical, Diagnostic, and Pharmaceutical Applications including Related Software, Services, Chromatography Columns, Accessories, Derived Assemblies and Consumables Certificate Expiry Date: December 31, 2023 Certificate Registration No: 951 21 5321 Issue Date: January 1, 2021 Reissue Date: September 22, 2021 Greg Bates Director Business Assurance America Page 1 of 16 CERTIFICATE Santa Clara Corporate Headquarters Agilent Technologies, Inc 5301 Stevens Creek Boulevard Santa Clara, CA 95051 USA Scope – Central Function, Life Sciences and Applied Markets Group (LSAG). Product Design and Development, Marketing of Mass Spectrometers, Automated Systems and related Software for LSAG, Order Fulfillment of related Software. Headquarters for Enterprise Leadership and Coordination. Quality Engineering Services/Hardware Test Center. Headquarters for Enterprise Leadership and Coordination Agilent Technologies, Inc. 2450 SE Oak Tree Court, Suite 101, Ankeny, IA 50021 USA Scope – Product Design, Development and Order Fulfillment Activities of Electrophoresis-Based Analytical Instrument
    [Show full text]
  • Make Hunger History Awards
    Second harvest food Bank of SANTA CLARA and SAN Mateo CouNTieS Make Hunger History Awards Celebrating your efforts to end local hunger welcoMe PRogRAM Welcome to Second Harvest Food Bank’s Second HarveSt Food Bank’S Make Hunger History Awards! 22nd recognition event Although the reasons for hunger are complicated, feeding a Annual family in need is not. Because of your help and generosity, last year we were able to provide 41 million meals to children, seniors and hard-working adults who had nowhere else to turn. We served nearly a quarter of a million people every month last year. Make Hunger History it’s staggering to know that one in every 10 people in Silicon Valley and on the Peninsula received at least some of their food from the Food Bank. Awards Nationally, 70 billion pounds of food is wasted every year, far more than is needed by the 49 million people who struggle with tHurSday, april 4, 2013 hunger. You don’t have to be a “numbers person” to figure out 6:00 pm that there is enough food available to COCKTAIL reception feed our hungry neighbors. Hunger is a solvable problem. 7:00 pm AWARDS program The solution to hunger is connectivity. we are striving to make hunger history by Kathy Jackson, Ceo, Second Harvest Food Bank supplementing our highly efficient physical distribution of food by adopting new technology, orchestrating win-win collaborations and connecting more people to 2012 Holiday Food & Fund drive c o-cHairS: food that would otherwise be wasted. Tonight we’ll even meet Kate to see how the Dan Campbell, Coo, Backup and Recovery Systems, eMC Corporation Food Bank is connecting local families with the food they need to thrive.
    [Show full text]
  • 2019 Santa Clara Energizer Stations
    Location Organization Name Location Street Location City Start Time End Time Purple = SVBC Outreach Stations Adobe Systems, Inc 345 Park Avenue San Jose 6:15:00 AM 10:00:00 AM Agilent Technologies, Inc. 5301 Stevens Creek Boulevard Santa Clara 6:00:00 AM 10:00:00 AM 10500 N. De Anza Blvd De Anza Blvd and Apple Mariani Ave. Cupertino 7:00:00 AM 10:30:00 AM Apple Park Visitors Center at 10600 N. Apple Tantau Cupertino 7:00:00 AM 10:30:00 AM Apple Wolfe 01 at 280 N. Wolfe Road Sunnyvale 7:00:00 AM 10:30:00 AM Applied Materials and Sports Bowers Ave/Central Expwy (NW corner Basement island) Santa Clara 6:00:00 AM 10:00:00 AM Bicycle Blue Book 2240 Paragon Dr. San Jose 6:00:00 AM 11:00:00 AM Bloom Energy Vista Montana and N. 1st St., San Jose San Jose 6:30:00 AM 9:30:00 AM Coyote Creek Trail and McCarthy Ranch i.e. Bloom Energy Ranch Dr. Milpitas 6:30:00 AM 9:30:00 AM Cadence Design Systems 2655 Seely Avenue San Jose 6:30:00 AM 9:30:00 AM Guadalupe River Trail W, at the intersection Callander Associates with Airport Pkwy San Jose 8:00 AM 10:00 AM Cambrian Library 1780 Hillsdale Ave San Jose 6:30:00 AM 10:00:00 AM intersection of Bryant Street and Lowell Castilleja Avenue Palo Alto 7:30 AM 8:30 AM Center for Sustainability - Santa Clara University The Alameda and Market St.
    [Show full text]
  • Agilent Technologies, Inc
    AGILENT TECHNOLOGIES, INC. ANNUAL REPORT TO STOCKHOLDERS ANNUAL REPORT CONSOLIDATED FINANCIAL STATEMENTS 2010 Annual Report ANNUAL REPORT TO STOCKHOLDERS ANNUAL REPORT CONSOLIDATED FINANCIAL STATEMENTS 2010 This page is intentionally left blank. To our shareholders, Fiscal 2010 was a strong year for Agilent. Annual revenues were up almost $1 billion from fiscal 2009, an increase of 21 percent. Operating profit and earnings per share also increased substantially. In addition to benefiting from the acquisition of Varian which closed mid-year, we also saw very healthy organic growth in each of our businesses. Overall, Agilent is capitalizing well on the market upturn as the global economy recovers. Annual Report In addition to our strong fiscal 2010 financial results, we completed several strategic milestones. We executed a major restructuring of our electronic measurement business group. We completed the acquisition of Varian, the largest acquisition in our history, to strengthen our bio- analytical businesses. And we established a new business group to focus on the pursuit of the life science market, our largest measurement opportunity in the coming years. Electronic Measurement Group Agilent’s Electronic Measurement Group (EMG) provides solutions in communications, industrial, aerospace and defense, semiconductor and computer measurement markets. As the company’s oldest and most established business, EMG’s heritage dates back more than 70 years to the founding of Agilent’s predecessor company, Hewlett-Packard. Core technology platforms include oscilloscopes, signal analyzers, spectrum analyzers and network analyzers. Electronic Measurement was the business most affected by the 2009 economic recession, due to its exposure to the industrial and consumer markets. Agilent’s management team took proactive actions as early as late 2008 to ensure EMG’s health through the economic downturn.
    [Show full text]