Installation, Operation and Maintenance Manual
Total Page:16
File Type:pdf, Size:1020Kb
INSTALLATION, OPERATION AND MAINTENANCE MANUAL LINEAR GAS BURNER: G37T ROUND GAS BURNER: G16T ESF.2.B.G37 7.5lbs/3.4kg ESF.2.B.G16 5.5lbs/2.5kg INSTALLER: Leave manual with the appliance. CONSUMER: Retain this manual for future reference. CAUTION WARNING DO NOT DISCARD THIS MANUAL Improper installation, adjustment, alteration, service, • Important operating and maintenance instructions or maintenance can cause injury or property damage. included. Read the installation and maintenance instructions • Read, understand, and follow these instructions for thoroughly before installing or servicing this equipment. safe installation and operation. DANGER DANGER CARBON MONOXIDE HAZARD If you smell gas: This appliance can produce carbon • Shut off gas to the appliance. monoxide which has no odor. • Extinguish any open flame. Using it in an enclosed space can kill • If odor continues, keep away from the appliance you. and immediately call your gas supplier or fire Never use this appliance in an department. enclosed space such as a camper, • After leaving the area, call your gas supplier or fire tent, car or home. department. • Failure to follow these instructions could result in fire, or explosion, which could cause property WARNING damage, personal injury or death. If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. WARNING Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of this or any WARNING other appliance. An LP-cylinder not connected for use shall not be For outdoor use only. Installation and service must be stored in the vicinity of this or any other appliance. performed by a qualified installer, service agency, or the gas supplier. FLAMMABLE GAS UNDER PRESSURE. DANGER: LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED CAUSING SERIOUS BODILY INJURY OR DEATH. CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF A CYLINDER OR UNUSED LP-GAS. WARNING: FOR OUTDOOR USE ONLY.* DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE, OR ENCLOSED AREA. WARNING: WHEN CONNECTING FOR USE: x Know the odor of LP-gas. If you hear, see, x Use only in compliance with applicable codes. or smell leaking LP-gas, immediately get everyone x Read and follow manufacturer’s instructions. away from the cylinder and call the Fire Department. x Consult manufacturer’s instructions concerning the Do not attempt repairs. cylinder connection provided with your appliance. x Caution your LP-gas supplier to: x Be sure the regulator vent is not pointing up. x Be certain cylinder is purged of trapped x Turn off all valves on the appliance. air prior to first filling. x Do not check for gas leaks with a match or open x Be certain not to over fill the cylinder. flame. Apply soapy water at areas marked “X”. Open x Be certain cylinder requalification date is cylinder valve. If bubbles appear, close valve and checked. have LP-gas service person make needed repairs. x LP-gas is heavier than air and may settle in low places Also, check appliance valves and connections to make while dissipating. sure they do not leak before lighting appliance. x Contact with the liquid contents of cylinder will cause x Light appliance(s) following manufacturer’s freeze burns to the skin. instructions. x Do not allow children to tamper or play with cylinder. x When appliance is not in use, keep the cylinder valve x When not connected for use, keep cylinder valve closed. turned off. Self-contained appliances shall be limited to a cylinder of 30 lb. capacity or less. x Do not use, store or transport cylinder where it would be exposed to high temperatures. Relief valve may open allowing a large amount of flammable gas to escape. x When transporting, keep cylinder secured in an upright position with cylinder valve turned off. DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL *EXCEPT AS AUTHORIZED BY ANSI/NFPA 58 DANGER: Do not store a spare LP cylinder under or near a barbecue grill, or other heat sources. NEVER fill an LP cylinder beyond 80% full: a fire causing death or serious injury may occur. Page2 | 2 www.outdoorrooms.com www.outdoorrooms.com BCH-1242 42477 REV B 08-4250820-18 REV B : CFP : 08-13-2019 EDUCATE ALL USERS Manuals can be found on our website or by contacting your local distributor. WHY REGISTER YOUR WARRANTY? LISTING AND CODE APPROVALS Registering your warranty achieves more than simply activating your A. Appliance Certification warranty - it provides our head office with the information that we require in order to communicate important safety and regulatory MODEL: ESF.2.B.G37, ESF.2.B.G16 information to you should the need arise. LABORATORY: Underwriters Laboratories, Inc. (UL) This could include things like: TYPE: Decorative Gas-Fired Outdoor Fireplace STANDARD: Outdoor Decorative Gas Appliances • Prompt notification in the unlikely event of a potential hazard, ANSI Z21.97-2017 CSA 2.41-2017 • Reminders about regular safety steps and maintenance procedures, • New model announcements or accessories that suit or enhance This appliance has been tested in accordance with ANSI Z21.97-2017 your purchase. and CSA 2.41-2017 for Canada and has been listed by Underwriters Laboratory (UL) for installation and operation as described in these It is important that we are able to communicate effectively with our installation and operating instructions. customers as part of our commitment to continual improvement, The installation must conform with local codes or, in the absence of consumer safety and property protection. local codes, ANSI Z223.1 * NFPA 54 National fuel gas code – Natural gas and propane installation code, CSA B149.1 – or propane storage If you purchased your product through an external distributor, retailer and handling code, CSA B149.2 or agent. MAD Design USA does not have these details on file and may have trouble sourcing them as systems and best practices vary from business to business. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with Please register your warranty today. You can do this online at the National Electrical Code, ANSI/NFPA 70; or the Canadian Electrical www.ecosmartfire.com or by sending through your details as itemized Code, CSA C22.1, if applicable. on page 24 via email to [email protected]. B. BTU Specifications MAD Design USA 5875 Green Valley Circle, Suite 100 Orifice Size Max Input BTU Culver City CA 90230 Model T + 1 (888) 590.3335 LP NG LP NG E [email protected] G16T ESF.2.B.G16 #40 (Burner) #29 (Burner) Low: 25,000 BTU/h G37T #52 (Valve) #43 (Valve) High: 65,000 BTU/h ESF.1.B.G37 PROPANE NATURAL GAS IDEAL INLET 11 in. WC (2.74 kPa) 7 in. WC (1.74 kPa) PRESSURE MAXIMUM INLET 14 in. WC (3.48 kPa) 10.5 in. WC (2.61 kPa) PRESSURE MINIMUM INLET 8 in. WC (2.00 kPa) 3.5 in. WC (0.87 kPa) PRESSURE © Copyright 2004 - 2020 EcoSmart Inc. All rights reserved. V0120 ENGLISH Contents Markings 3 Important Safety Information 3 - 4 Clearances 5 Before You Start 6 Gas Hookup 7 - 8 Standard Equipment Received 9 - 10 Burner Assembly - Propane 11 - 13 Burner Assembly - Natural Gas 14 - 17 Installation - Natural Gas 18 Lighting and Operating 19 Troubleshooting 20 - 21 Service and Maintenance 22 Reference Materials 23 Warranty 24 Markings Listing Label Information/Location The model information regarding your specific appliance can be found on the rating plate attached to your burner via a metal chain. See the sample rating plate below for locations of specifications. EcoSmart Inc DECORATIVE FOR YOUR SAFETY, 5875 Green Valley Circle READ BEFORE LIGHTING Suite 100, Culver City OUTDOOR GAS-FIRED MH60943 CA 90230 BURNER Outdoor Fireplace BURNER 42W4 This burner is for installation within approved MFG. DATE XX/XX WARNING! If you do not follow these instructions exactly, a fire or installation, ensure that all manual shut-off valves on the supply line explosion may result causing property damage, personal injury, are open. models ONLY and is not to be installed into and/or loss of life. custom designs. SERIAL # XXXX DATE DE FAB. XX/XX 5. Press and hold sparker button. Verify that an audible and visible A. This appliance is equipped with a safety ignition and shutdown spark is present inside the ignition wind guard. device, but must be lit manually. When lighting, follow these 6. Gently press and turn the control know counter-clockwise to the Model: EcoSmart Fire GB Series Orifice Size Max Input BTU instructions exactly. “LOW/IGNITION” position. Fully depress the knob and hold for 3-5 ANSI Z21.97-2017 and CSA 2.41-2017 for Canada. Model seconds until ignition is proven and the burner remains lit when the LP NG LP NG B. BEFORE LIGHTING, smell around the appliance area for gas. Be Installation must conform with local codes or in the knob released. G16T sure to smell next to the floor because some gas is heavier than air and will settle on the floor. 7. If burner does not light after 10 seconds of attempting ignition, absence of local codes, ANSI Z223.1 * NFPA 54 ESF.2.B.G16 #40 (Burner) #29 (Burner) Low: 25,000 BTU/h turn the valve clockwise to the “OFF” position and wait 5 minutes #52 (Valve) #43 (Valve) High: 65,000 BTU/h National Fuel Gas Code – Natural gas and propane G37T WHAT TO DO IF YOU SMELL GAS: to allow gas to dissipate before attempting ignition again. NO NOT installation code, CSA B149.1 – or propane storage ESF.1.B.G37 • Do not try to light any appliance.