Air Separation Unit for the Production of Liquid Oxygen, Nitrogen and Argon

Total Page:16

File Type:pdf, Size:1020Kb

Air Separation Unit for the Production of Liquid Oxygen, Nitrogen and Argon Air Separation Unit for the production of liquid Oxygen, Nitrogen and Argon Oxygen, Nitrogen and Argon of the highest purity Industries Low energy consumption • Manufacturers of industrial gases Air Separation Units using • automated process control cryogenic technology for the system which ensures the production of oxygen, nitrogen operating cycle can be and argon in liquid and gas adapted to meet variations in phases offer several advantages: product requirements; • high process efficiency, • remote monitoring service by proven and widely SIAD Macchine Impianti to demonstrated by the number monitor the operating status. of plants in operation; • easy installation and Technical standard maintenance thanks to the modular design and • The experience of SIAD construction; Macchine Impianti engineers, • high purity oxygen, nitrogen at the service of our and argon thanks to customers, has created cryogenic technology; a certified standard which • easy to use: fully automated is adaptable to the various system for easy and reliable requirements of small, medium “unattended” management; and large-sized industries. Liquid argon Technical data Liquid oxygen Liquid nitrogen ASU Model 3 3 (approximate) Nm /h - MTPD Nm /h - MTPD 3 Nm /h - MTPD • O2 purity: 99,6% • N purity: 99,9995% and up to AF 1000 1 000 - 34 2 600 - 77 35 - 1.5 2 1 ppm of O2 AF 3000 3 000 - 103 8 500 - 254 110 - 4.7 • Air purity: AF 5000 5 000 - 170 14 000 - 419 180 - 7.7 up to 1 ppm of O2 AF 8000 8 000 - 274 23 000 - 689 280 - 12.0 up to 1 ppm of N2 AF 10000 10 000 - 340 29 000 - 869 350 - 15.0 • “State of the art” technology with air or nitrogen liquefaction AF 15000 15 000 - 510 44 000 - 1 320 550 - 23.5 cycles; AF 20000 20 000 - 685 58 000 - 1 738 700 - 30.0 • Purification of argon using AF 25000 25 000 - 850 73 000 - 2 188 900 - 38.5 cryogenic technology. AF 30000 30 000 - 1 000 87 000 - 2 600 1 050 - 45.0 Customised solutions available Air Separation Units Division International construction and safety standards The standard design and construction procedures of SIAD Macchine Impianti comply with all the main international standards. Global Service Division: a complete range of services To reduce operating costs and to maintain the high efficiency of its Air Separation Units, SIAD Macchine Impianti offers its customers a complete range of services, together with a network of Certified Service Centres in five continents, operated by skilled technicians. • ASU maintenance and supply of spare parts: supply of spare parts; maintenance work; preventative maintenance; predictive maintenance. • Remote assistance for ASU management: remote monitoring/parameter checks. • On-site support: commissioning and start-up supervision; For further information: support for unit stop, restart and tuning. [email protected] • Training courses: on-site theoretical and practical courses; theoretical and practical courses at the SIAD Macchine Impianti works. Find out more about our range of services at our website www.siadmi.com © 2015 SIAD Macchine Impianti S.p.A. All rights reserved The information contained herein is offered for use by Printed in Italy technically qualified personnel at their discretion and 167uk12/15 risk without warranty of any kind. We regularly update our data. SIAD Macchine Impianti S.p.A. Società unipersonale soggetta all’attività di Telephone +39 035 327611 direzione e coordinamento di SIAD S.p.A. Fax +39 035 316131 24126 Bergamo, Italy - Via Canovine, 2/4 Share Capital € 25.000.000 paid up VAT and Fiscal Nr.: (IT) 00228420162 R.E.A. BG-72619 - Export: BG 006107 www.siadmi.com - [email protected] .
Recommended publications
  • Compressed Liquid Gases (Cryogens) Laboratory Safe Work Practices
    Compressed Liquid Gases (Cryogens) Laboratory Safe Work Practices Source: Section 3.9 of Guidelines for Safe Work Practices in Human and Animal Medical Diagnostic Laboratories: Recommendations of a CDC-convened, Biosafety Blue Ribbon Panel; excerpted by Vanderbilt OCRS, 10.2020. Compressed Liquid Gases (Cryogens) Cryogenic liquids are liquefied gases that have a normal boiling point below -238°F (-150°C). Liquid nitrogen is used in the microbiology laboratory to freeze and preserve cells and virus stocks. The electron microscopy laboratory, frozen section suites, and grossing stations for surgical pathology frequently use liquid nitrogen; some laboratories also use liquid helium. The principal hazards associated with handling cryogenic fluids include cold contact burns and freezing, asphyxiation, explosion and material embrittlement. Cold contact burns and freezing • Liquid nitrogen is dangerously cold (-320°F [-196°C]), and • Wear loose-fitting thermal gloves with elbow-length cuffs skin contact with either the liquid or gas phase can when filling dewars. Ensure that gloves are loose enough to immediately cause frostbite. At -450°F (-268°C), liquid be thrown off quickly if they contact the liquid. helium is dangerous and cold enough to solidify atmospheric • Never place gloved hands into liquid nitrogen or into the air. liquid nitrogen stream when filling dewars. Gloves are not • Always wear eye protection (face shield over safety goggles). rated for this type of exposure. Insulated gloves are The eyes are extremely sensitive to freezing, and liquid designed to provide short-term protection during handling of nitrogen or liquid nitrogen vapors can cause eye damage. hoses or dispensers and during incidental contact with the • Do not allow any unprotected skin to contact uninsulated liquid.
    [Show full text]
  • Cryogenics – the Basics Or Pre-Basics Lesson 1 D
    Cryogenics – The Basics or Pre-Basics Lesson 1 D. Kashy Version 3 Lesson 1 - Objectives • Look at common liquids and gases to get a feeling for their properties • Look at Nitrogen and Helium • Discuss Pressure and Temperature Scales • Learn more about different phases of these fluids • Become familiar with some cryogenic fluids properties Liquids – Water (a good reference) H2O density is 1 g/cc 10cm Total weight 1000g or 1kg (2.2lbs) Cube of water – volume 1000cc = 1 liter Liquids – Motor Oil 10cm 15W30 density is 0.9 g/cc Total weight 900g or 0.9 kg (2lbs) Cube of motor oil – volume 1000cc = 1 liter Density can and usually does change with temperature 15W30 Oil Properties Density Curve Density scale Viscosity scale Viscosity Curve Water density vs temperature What happens here? What happens here? Note: This plot is for SATURATED Water – Discussed soon Water and Ice Water Phase Diagram Temperature and Pressure scales • Fahrenheit: 32F water freezes 212 water boils (at atmospheric pressure) • Celsius: 0C water freezes and 100C water boils (again at atmospheric pressure) • Kelvin: 273.15 water freezes and 373.15 water boils (0K is absolute zero – All motion would stop even electrons around a nucleus) • psi (pounds per square in) one can reference absolute pressure or “gage” pressure (psia or psig) • 14.7psia is one Atmosphere • 0 Atmosphere is absolute vacuum, and 0psia and -14.7psig • Standard Temperature and Pressure (STP) is 20C (68F) and 1 atm Temperature Scales Gases– Air Air density is 1.2kg/m3 => NO Kidding! 100cm =1m Total weight
    [Show full text]
  • Cryogenic Liquid Nitrogen Vehicles (ZEV's)
    International Journal of Scientific and Research Publications, Volume 6, Issue 9, September 2016 562 ISSN 2250-3153 Cryogenic Liquid Nitrogen Vehicles (ZEV’S) K J Yogesh Department Of Mechanical Engineering, Jain Engineering College, Belagavi Abstract- As a result of widely increasing air pollution available zero emission vehicle (ZEV) meeting it's standards are throughout the world & vehicle emissions having a major the electrically recharged ones, however these vehicles are also contribution towards the same, it makes its very essential to not a great success in the society due to its own limitations like engineer or design an alternative to the present traditional initial cost, slow recharge, speeds etc. Lead acid & Ni-Cd gasoline vehicles. Liquid nitrogen fueled vehicles can act as an batteries are the past of major technologies in the electric excellent alternative for the same. Liquefied N2 at cryogenic vehicles. They exhibit specific energy in the range of 30-40 W- temperatures can replace conventional fuels in cryogenic heat hr/kg. Lead- acid batteries take hours to recharge & the major engines used as a propellant. The ambient temperature of the drawback of the batteries in all the cases is their replacement surrounding vaporizes the liquid form of N2 under pressure & periodically. This directly/indirectly increases the operating cost leads to the formation of compressed N2 gas. This gas actuates a when studied carefully & thereby not 100% acceptable. pneumatic motor. A combination of multiple reheat open Recent studies make it clear that the vehicles using liquid Rankine cycle & closed Brayton cycle are involved in the nitrogen as their means provide an excellent alternative before process to make use of liquid N2 as a non-polluting fuel.
    [Show full text]
  • Protocol for Use and Maintenance of Oxygen Monitoring Devices 2021
    National Institutes of Health Protocol for Use and Maintenance of Oxygen Monitoring Devices 2021 Authored by the Division of Occupational Health and Safety (DOHS) Oxygen Monitoring Program Manager. CONTENTS INTRODUCTION………………………………………………………………... 2 I. PURPOSE………………………………………………………………… 2 II. SCOPE……………………………………………………………………. 2 III. APPLICABLE REGULATORY, POLICY, AND INDUSTRY STANDARDS………………………………………... 3 IV. RESPONSIBILITIES …………………………………………….………. 4 V. TECHNICAL INFORMATION………………………………………….. 6 VI. REFERENCES…………………………………………………….……… 9 APPENDIX A – MANDATORY SIGNAGE………………………………….… 11 APPENDIX B – RECOMMENDED SIGNAGE………………………………… 13 ACRONYMS BAS Building Automation System DOHS Division of Occupational Health and Safety DRM Design Requirements Manual IC Institute/Center MRI Magnetic Resonance Imaging NMR Nuclear Magnetic Resonance OSHA Occupational Safety and Health Administration PI Principal Investigator TEM Transmission Electron Microscope TAB Technical Assistance Branch Disclaimer of Endorsement: Reference herein to any specific commercial products, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government, and shall not be used for advertising or product endorsement purposes. 1 INTRODUCTION Compressed gases and cryogenic liquids (e.g. nitrogen, helium, carbon dioxide, oxygen and argon)
    [Show full text]
  • Liquid Nitrogen Safety
    Michigan Technological University, Department of Physics Liquid Nitrogen Safety Adapted from Department of Chemical Engineering Safety Manual and: http://engineering.dartmouth.edu/microengineering/ln2.html Properties of Liquid Nitrogen (LN2) 1. It is extremely cold: 77.3K = -196C = -320F at atmospheric pressure. This can cause severe frost bite 2. On vaporization it expands by a factor of 700; one liter of liquid nitrogen becomes 24.6 cubic feet of nitrogen gas. This can cause explosion of a sealed container, or it can displace oxygen in the room and cause suffocation without warning. 3. It can become oxygen enriched and cause ordinarily noncombustible materials to burn rapidly. Personal Protection When Handling LN2 1. When handling LN2 you should maximize the protection offered by clothing. Wear full sleeves, long pants and non-porous closed-toe shoes. 2. Splashing is common, so safety goggles or a face shield should be worn at all times when working with LN2. 3. Wear protective gloves when touching any object cooled by liquid nitrogen. However, the gloves should be loose fitting, so they could be thrown off if liquid were to pour inside them. 4. Care must be taken to prevent uninsulated containers from contacting unprotected skin since they may become bonded to the skin and will serious injury. 5. Contact of the skin with LN2 can cause severe cryogenic burns (tissue damage is similar to frostbite or thermal burns). Although small amounts of LN2 quickly evaporate when on the skin surface, if the liquid becomes trapped under jewelry, watches, or inside gloves or folds of clothing, it can result in serious and painful burns.
    [Show full text]
  • Safety Advice. Cryogenic Liquefied Gases
    Safety advice. Cryogenic liquefied gases. Properties Cryogenic Liquefied Gases are also known as Refrigerated Liquefied Gases or Deeply Refrigerated Gases and are commonly called Cryogenic Liquids. Cryogenic Gases are cryogenic liquids that have been vaporised and may still be at a low temperature. Cryogenic liquids are used for their low temperature properties or to allow larger quantities to be stored or transported. They are extremely cold, with boiling points below -150°C (-238°F). Carbon dioxide and Nitrous oxide, which both have higher boiling points, are sometimes included in this category. In the table you may find some data related to the most common Cryogenic Gases. Helium Hydrogen Nitrogen Argon Oxygen LNG Nitrous Carbon Oxide Dioxide Chemical symbol He H2 N2 Ar O2 CH4 N2O CO2 Boiling point at 1013 mbar [°C] -269 -253 -196 -186 -183 -161 -88.5 -78.5** Density of the liquid at 1013 mbar [kg/l] 0.124 0.071 0.808 1.40 1.142 0.42 1.2225 1.1806 3 Density of the gas at 15°C, 1013 mbar [kg/m ] 0.169 0.085 1.18 1.69 1.35 0.68 3.16 1.87 Relative density (air=1) at 15°C, 1013 mbar * 0.14 0.07 0.95 1.38 1.09 0.60 1.40 1.52 Gas quantity vaporized from 1 litre liquid [l] 748 844 691 835 853 630 662 845 Flammability range n.a. 4%–75% n.a. n.a. n.a. 4.4%–15% n.a. n.a. Notes: *All the above gases are heavier than air at their boiling point; **Sublimation point (where it exists as a solid) Linde AG Gases Division, Carl-von-Linde-Strasse 25, 85716 Unterschleissheim, Germany Phone +49.89.31001-0, [email protected], www.linde-gas.com 0113 – SA04 LCS0113 Disclaimer: The Linde Group has no control whatsoever as regards performance or non-performance, misinterpretation, proper or improper use of any information or suggestions contained in this instruction by any person or entity and The Linde Group expressly disclaims any liability in connection thereto.
    [Show full text]
  • Guidance for the Safe Operation of Liquid Nitrogen Freezers for Cryo-Preservation
    Safetygram 49 Guidance for the safe operation of liquid nitrogen freezers for cryo-preservation. Biological activity reduces as temperature decreases. At temperatures below about -135oC, this activity effectively stops and therefore biological materials (e.g. cells, tissues, blood) can be stored at -135oC or below without significant deterio- ration. This process is known as cryo-preservation. Commonly this is done by storing the samples in freezers containing nitrogen in its liquid phase (-196oC) or its cold vapour phase (-135oC to -190oC). This Safetygram addresses the safe use of liquid nitrogen cryo-preservation equipment. The hazards posed by this equipment are commonly due to: • The expansion of liquid nitrogen (by a factor of about 700) as it evaporates. This can lead to a displacement of oxygen from the atmosphere in poorly ventilated areas, which can cause asphyxiation and ultimately may be fatal. Storage or transport of liquid nitrogen in unvented containers will rapidly lead to over-pressurisation and explosion. • The extremely low temperature of liquid nitrogen which can burn exposed flesh. Many materials become brittle at liquid nitrogen temperatures so vessels and piping have to be constructed from a limited range of suitable materials. General Precautions Guard against oxygen deficiency. There have been incidents where users of freezers have been exposed to potential harm when nitrogen has escaped from a cryogenic storage vessel and reduced the surrounding oxygen concentration to an unacceptably low level. Persons using or maintaining the freezing equip- ment need to be aware that although nitrogen itself is non-toxic, it can reduce the oxygen concentration of atmospheric air locally to levels that may become hazardous to health and potentially fatal.
    [Show full text]
  • Care and Maintenance of a Liquid Nitrogen Tank
    Care and Maintenance of a Liquid Nitrogen Tank liquid nitrogen tank is a cryogenic storage container that can be used for preserving and A storing semen for an extended period of time. Semen is a significant cost in an artificial insemination program, and maintaining a liquid nitrogen tank’s integrity is key to protecting that investment. A liquid nitrogen tank is not inexpensive but can last for many years with proper care and maintenance. Understanding liquid nitrogen Under normal atmospheric conditions, the nitrogen we encounter is in the gaseous phase rather than the liquid phase. In fact, the air we breathe is approximately 78% nitrogen gas. Nitrogen is primarily observed in the gaseous phase because it boils at the extremely low temperature of -320 degrees F. Atmospheric nitrogen gas can liquefied using a series of commercial steps, producing liquid nitrogen that can be used for cryopreservation. However, liquid nitrogen rapidly boils off into the gaseous phase when exposed to normal atmospheric conditions. Structure of a liquid nitrogen tank A liquid nitrogen tank is a double-walled container in which two tanks are fused together with a fiberglass neck (Figure 1). During the manufacturing process, a vacuum Figure 1. A cutaway tank showing the internal structure of a liquid is drawn in the space between these two containers. nitrogen tank. The vacuum aids in the insulation of the inner tank and ensures that nitrogen evaporates much more slowly nitrogen gas is allowed to escape in order to prevent than it would if simply exposed to air. As long as there is pressure build up.
    [Show full text]
  • Liquid Densities of Oxygen, Nitrogen, Argon and Parahydrogen 6
    NATL INST OF STAND & TECH A111D7 231A72 NBS TECHNICAL NOTE 361(Revised) *+ •«, - *EAU O* Metric Supplement May 1974 U.S. DEPARTMENT OF COMMERCE /National Bureau of Standards Liquid Densities of Oxygen, Nitrogen, Argon and Parahydrogen NATIONAL BUREAU OF STANDARDS The National Bureau of Standards ' was established by an act of Congress March 3, 1901. The Bureau's overall goal is to strengthen and advance the Nation's science and technology and facilitate their effective application for public benefit. To this end, the Bureau conducts research and provides: (1) a basis for the Nation's physical measurement system, (2) scientific and technological services for industry and government, (3) a technical basis for equity in trade, and (4) technical services to promote public safety. The Bureau consists of the Institute for Basic Standards, the Institute for Materials Research, the Institute for Applied Technology, the Institute for Computer Sciences and Technology, and the Office for Information Programs. THE INSTITUTE FOR BASIC STANDARDS provides the central basis within the United States of a complete and consistent system of physical measurement; coordinates that system with measurement systems of other nations; and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scientific community, industry, and commerce. The Institute consists of a Center for Radiation Research, an Office of Meas- urement Services and the following divisions: Applied Mathematics — Electricity — Mechanics — Heat
    [Show full text]
  • Cryogenic Liquid Containers
    Safetygram 27 Cryogenic liquid containers Cryogenic liquid containers, also referred to as liquid cylinders, are double-walled vacuum vessels with multilayer insulation in the annular space. They are designed for the reliable and economic transportation and storage of liquefied gases at cryogenic temperatures, typically colder than –130°F (–90°C). There are two primary advantages of a liquid container. The first is that it contains a large volume of gas at a relatively low pressure compared to a compressed gas cylinder. The second is that it provides a source of cryogenic liquids which can be easily handled. Cryogenic liquid containers are often incorrectly referred to as dewars. Dewars are open, nonpressurized vessels for holding cryogenic liquids. The cryogenic products normally found in liquid containers are liquid nitrogen (LIN), liquid argon (LAR), liquid oxygen (LOX), and liquid helium (LHE). Carbon dioxide and nitrous oxide are also available as refrigerated liquids in similar containers. Although these containers are well insulated, heat will continuously leak into the product, due to the extremely large temperature difference between the cryogenic liquid and the ambient environment. The heat leak will cause some vaporization to occur. Vaporized product, if not used, will collect in the vapor space above the liquid and build pressure. This is referred to as head pressure. The head pressure will build in the container and periodically vent via the pressure relief valve. Vaporization rates will vary and may be as low as 0.4% or as high as 3% of the container’s volume per day. This is a normal and safe function of the container.
    [Show full text]
  • Liquid Nitrogen Handling and Use
    Liquid Nitrogen Handling and Use Overview Liquid nitrogen (LN2) is inert, colorless, odorless, non-corrosive, non-flammable, tasteless, extremely cold, and has no warning properties. It poses a risk of explosion if stored in unvented containers and asphyxiation if not used in well-ventilated areas. Special care must be taken by personnel who handle or work in areas where liquid nitrogen is used. Additionally, the New York City Fire Department has specific requirements and restrictions associated with the safe storage, handling, and use of liquid nitrogen. Applicability This Update includes information from the updated New York City Fire Code, which implemented new regulations regarding the storage and use of cryogenic liquids (including LN2). All labs that store or use liquid nitrogen must comply with the Handling and Storage requirements listed in this Update. In addition, this Update provides general hazard warning and safety precaution information to users of LN2. Laboratory personnel who work with or in areas where LN2 is used must know and understand these guidelines. Responsibilities Personnel working with LN2 must follow this Update and contact EHS for assistance and training as needed. Formerly the G-97, the G-79 Certificate of Fitness (CoF) for the “Supervision of Storage, Handling and Use of Commercial Cryogenic Systems ” applies to cryogenic liquids NOT stored or used in an FDNY-permitted laboratory. If cryogenic liquids are stored or used in an FDNY-permitted laboratory, only the C-14 “Supervising Non-Production Chemical Laboratories” CoF is required. Environmental Health and Safety (EHS) provides assistance and training on the safe handling and use of LN2 upon request and provides assistance to personnel applying for the C-14 or G-79 CoF.
    [Show full text]
  • Cryogenic Liquid Containers
    Cryogenic Liquid Containers Cryogenic liquid containers, also referred All cryogenic liquids produce large vol- If liquid oxygen is released, an oxygen- to as liquid cylinders, are designed for the umes of gas when they vaporize. The enriched atmosphere could result. An oxy- reliable and economic transportation and expansion ratio is the amount of gas gen- gen-enriched atmosphere is dangerous storage of liquefied gases at cryogenic erated from a given amount of liquid. Table due to the increased potential for a fire to temperatures, typically colder than – 130ºF 1 shows the liquid-to-gas expansion ratios occur. Although oxygen itself is nonflam- (-90ºC). The products found in liquid con- for the common cryogenic fluids. If a suffi- mable, ordinary combustible materials will tainers are nitrogen, argon, oxygen, helium, cient amount of liquid is vaporized within a burn more vigorously. Materials that nor- carbon dioxide and nitrous oxide. The con- closed container, it will produce enormous mally do not burn in air may burn in an tainers are double-walled, vacuum vessels pressures that could rupture the vessel. oxygen-enriched atmosphere. with multilayer insulation in the annular For this reason, cryogenic liquid containers space. The two primary advantages of a are protected with multiple pressure relief Elevator Transport liquid container are that it contains a large devices. Similarly, any system for the stor- Section to Be Modified please come back volume of gas at a relatively low pressure age and delivery of cryogenic liquids later. and it provides a source of cryogenic liq- should be carefully designed to avoid trap- uids which can be easily handled.
    [Show full text]