Managing Humidity in Cold Store Installations MANAGING HUMIDITY IN COLD STORE INSTALLATIONS COTES.COM MANAGING HUMIDITY IN COLD STORE INSTALLATIONS COTES.COM HUMIDITY – THE INVISIBLE PART OF THE CONTROL EQUATIONS DIFFICULTIES GET DEALT WITH Cooling goods for low-temperature storage can often lead to big problems with unwanted ice and condensation – all caused by humidity. Humidity is is an invisible parameter that can ratch up operating costs and punch big holes in customer satisfaction. Cotes adsorption dehumidifier solutions enable you to tackle the fundamental reasons why ice and condensation even arise – giving you full control over conditions, lower operating costs and greater customer satisfaction. COTES.COM CONTENTS 07 TARGETING SYMPTOMS OR ROOT CAUSES? 08 Do you have a humidity problem? 13 PRACTICAL ISSUES COMMON IN COLD STORE SET-UPS 14 Where ice and condensation form 16 A plethora of practical problems 18 Have you got problems with ice and condensation? 23 NO TWO COLD STORE SET-UPS ARE THE SAME 24 Your challenges are unique 26 What needs to be considered? 28 Different conditions – different solutions 30 Different refrigeration and freezing set-ups 33 HOW TO TACKLE ICE AND CONDENSATION 34 Defrosting makes a difference 38 The dehumidification approach 39 How it works 40 What does it cost? 41 What really happens? 42 How it’s installed 47 Recommended action 49 HOW COTES CAN HELP 50 Cotes recommends 54 Prevention is better than cure 56 Effective humidity management brings down your operating costs 57 The benefits add up 58 Cotes All-round 59 Cotes Flexible 61 EXPERTS IN MANAGING HUMIDITY TARGETING SYMPTOMS OR ROOT CAUSES? DIFFICULTIES GET DEALT WITH SYMPTOMS OR CAUSES? Cooling goods for low-temperature storage can often The problem is that this is only dealing with the lead to problems because humidity present in the air symptoms – not the root causes. Patching not makes ice and condensation form – resulting in loads preventing. of bothersome practical difficulties and revenue- nibbling costs. Cotes adsorption dehumidifier solutions enable you to tackle the basic physics of why ice and Most companies that operate refrigerated or freezer condensation even arise – giving you full control storage facilities have learned to tackle the normal over conditions, big savings because you don’t day-to-day ice and condensation problems, or need to spend money on costly preventive have invested in ways to keep them to a minimum. measures, and satisfied customers because goods Efficiency, customer satisfaction and profit margins don’t get spoilt or get their packaging damaged depend on it. while stored in your facility. The sums add up – big time. 7 DO YOU HAVE A HUMIDITY PROBLEM? HUMIDITY CAN’T BE SEEN THESE PROBLEMS It can be difficult to know how much humidity is Nevertheless, humidity – and in particular the tangible actually present inside your cold store set-up. The results of uncontrolled humidity – can have big USUALLY NEED DEALING moisture is in the air, and you can’t actually see effects on a wide range of your operating costs. The humidity – just the tell-tale signs that it’s there. problem is that the links between cause and effect WITH BECAUSE: aren’t always obvious. > They give rise to additional costs that burden your BUT THE SYMPTOMS CAN budgets and affect profit margins THE TELL-TALE SYMPTOMS ARE THINGS LIKE: > They represent damage to stored goods and their packaging – which is bad for business and soon means dissatisfied customers > They give rise to work environment issues and conditions that are dangerous for anyone working Ice forming on fixtures and Water and ice accumulating Ice and ice pickles forming in or passing through the facility equipment, and blocking and causing problems on cold surfaces evaporators > They represent lack of control over operating conditions, thus affecting quality assurance and good practice in cold store management. Stored goods getting wet Mist forming in the air and damaged 8 9 ICE BUILD-UP IN A FROZEN GOODS HOW BIG IS THE PROBLEM? STORAGE FACILITY 100 Ice and condensation will always form to some The deciding factor usually lies in the balance -18°C 80 Φ=90% degree in any refrigerated or freezer storage facility between cost and benefit. When ice and condensation – you can’t escape the basic laws of physics. start making a significant impact on your operating costs, customer retention statistics or work safety 60 Ice build-up in a frozen goods Φ=50% The question is whether there is an acceptable record, it’s probably time to do something about it. storage facility as a result of level? At what point you should you actually 40 different air conditions. ] (1 litre = 0.2 kg) take any measures needed to limit or control any /h L 2 [ =30% undesirable levels of humidity that give rise to such Moisture entry is through a 6m 20 Φ ice and condensation? When does an irritant and a opening with doors that open ICE bugbear become an unacceptable cost? for 10 seconds, 10 times an hour 0 (on average). 0 5 10 15 20 25 EXTERNAL DRY TEMPERATURE (˚C) CAN YOU REALLY EXAMPLE OF MOISTURE LOAD FROM CONTROL HUMIDITY? DOOR OPENINGS TYPICAL COLD STORE The formation of ice and condensation is pretty However, the basic laws of physics mean that ice DOORWAY FROST ACCUMULATION much inevitable in any refrigerated or freezer storage and condensation can, in fact, be kept from forming facility – and probably has been ever since mankind by controlling and adjusting the conditions present How the air moves when a door is opened ICE CRYSTALS opened the door on industrial refrigeration. in the air. between a warm and a cold room. The layman perception is that it’s a persistent, In many existing set-ups, the only realistic, reliable nagging problem that seems unavoidable. way to do this is by adsorption dehumidification – applied in the appropriate manner. 5 C 80% RH LOADING DOCK WARM INFLOW - 25 C 90% RH WHAT DO HUMIDITY PROBLEMS FREEZER COST YOU? COLD OUTFLOW MIST ICE ON FLOOR What do humidity problems cost you? What will it Cotes experts have solid practical experience with cost to make changes in your cold store set-up, and helping customers determine the exact costs and to introduce humidity management? Will it actually benefits associated with humidity and its control. A door 3 metres high and 2 metres wide is opened The moisture load from such a door (disregarding pay to make any changes/improvements? Please contact us to hear more. 10 times per hour for 10 seconds. The external draughts during opening) is then around 2.5 climate conditions are 8 °C and 80% relative kg/hour. humidity. The conditions inside the cold storage facility are -18 °C and T_dew = -20 °C). A cold storage facility with four such doors will then be exposed to the ingress of 10 kg moisture/hour. 10 11 PRACTICAL ISSUES COMMON IN COLD STORE SET-UPS SOURCES OF HUMIDITY Ice and condensation stem from air laden with undesirable moisture, undergoing a phase change when certain specific conditions arise. The most common sources of such moisture-laden air are: > Points of entry where doors/barriers are open for too long and/or close too slowly > Inappropriately sealed doors/openings in the outer structure > Ineffective sluices and other areas where goods are “in transition” > The goods stored within the facility > People and vehicles present within the facility > Pressure equaliser set-ups. 12 13 WHERE ICE AND CONDENSATION FORM FLOORS WALLS OTHER TECHNICAL STORED GOODS EQUIPMENT CEILINGS AROUND EVAPORATORS UNFORESEEN PLACES 14 15 A PLETHORA OF PRACTICAL PROBLEMS Unwanted ice and condensation can cause a wide range of costly problems in cold store facilities. In consultation with industry experts, Cotes specialists have identified the following as the most serious and the most widespread problems. REDUCED PRODUCT SAFETY ISSUES REDUCED PRODUCT POOR WORKING WASTED MAN-HOURS HIGHER ENERGY QUALITY HANDLING EFFICIENCY ENVIRONMENT AND REDUCED BILLS AND CUSTOMER PRODUCTIVITY SATISFACTION HOWEVER, IN GENERAL THE SITUATION IS AS FOLLOWS: Melting ice or pooled Ice and condensation result in Ice and condensation can result Formation of ice makes it difficult Once formed, ice needs to be Ice and condensation in cold condensation can damage the slippery floors in many small hindrances to to close doors and other openings removed and condensation needs stores need to be removed packaging of goods in the cold b Staff can slip/fall, forklift effective, error-free transport, properly to be dried up before it freezes b Additional energy store facility trucks, pallet movers and other stacking and logistics b Draughts, additional ingress to ice consumption for defrosting b Greater waste, reduced profit equipment can skid and cause b Reduced product handling of moisture-laden air, etc. b Constant need to use of fixtures, fittings and margins and negative effect on accidents and injuries as well efficiency and higher costs manpower for non-productive refrigeration equipment customer relations as damaging goods, equipment Staff experience a cold working purposes and fixtures Ice can form on the barcodes on environment with high levels of Evaporators work inefficiently Undesirable moisture can result in products, packaging and pallets humidity as colder/more uncom- Ice and condensation result when iced up both damage and contamination Humidity in the air can cause b Product IDs/labels falling fortable than an environment with in slower movement and more b Additional energy of goods in the facility mist and reduced visibility off or cannot be read/scanned the same temperatures but low accidents consumption b Health risks, greater waste, b Accidents affecting staff, effectively, resulting in humidity b Lower productivity and higher reduced profit margins and vehicles, goods, equipment and non-productive time and b Lower staff morale, higher manpower costs for treatment/ In some cold stores floors are negative effect on customer fixtures workflow inefficiencies margins absenteeism statistics compensation/insurance, etc.
Recommended publications
  • Solar Heating and Cooling & Solar Air-Conditioning Position Paper
    Task 53 New Generation Solar Cooling & Heating Systems (PV or solar thermally driven systems) Solar Heating and Cooling & Solar Air-Conditioning Position Paper November 2018 Contents Executive Summary ............................................................. 3 Introduction and Relevance ................................................ 4 Status of the Technology/Industry ...................................... 5 Technical maturity and basic successful rules for design .............. 7 Energy performance for PV and Solar thermally driven systems ... 8 Economic viability and environmental benefits .............................. 9 Market status .................................................................................... 9 Potential ............................................................................. 10 Technical potential ......................................................................... 10 Costs and economics ..................................................................... 11 Market opportunities ...................................................................... 12 Current Barriers ................................................................. 12 Actions Needed .................................................................. 13 This document was prepared by Daniel Neyer1,2 and Daniel Mugnier3 with support by Alexander Thür2, Roberto Fedrizzi4 and Pedro G. Vicente Quiles5. 1 daniel neyer brainworks, Oberradin 50, 6700 Bludenz, Austria 2 University of Innsbruck, Technikerstr. 13, 6020 Innsbruck, Austria
    [Show full text]
  • Ammonia As a Refrigerant
    1791 Tullie Circle, NE. Atlanta, Georgia 30329-2305, USA www.ashrae.org ASHRAE Position Document on Ammonia as a Refrigerant Approved by ASHRAE Board of Directors February 1, 2017 Expires February 1, 2020 ASHRAE S H A P I N G T O M O R R O W ’ S B U I L T E N V I R O N M E N T T O D A Y © 2017 ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE’s prior written permission. COMMITTEE ROSTER The ASHRAE Position Document on “Ammonia as a Refrigerant” was developed by the Society’s Refrigeration Committee. Position Document Committee formed on January 8, 2016 with Dave Rule as its chair. Dave Rule, Chair Georgi Kazachki IIAR Dayton Phoenix Group Alexandria, VA, USA Dayton, OH, USA Ray Cole Richard Royal Axiom Engineers, Inc. Walmart Monterey, CA, USA Bentonville, Arkansas, USA Dan Dettmers Greg Scrivener IRC, University of Wisconsin Cold Dynamics Madison, WI, USA Meadow Lake, SK, Canada Derek Hamilton Azane Inc. San Francisco, CA, USA Other contributors: M. Kent Anderson Caleb Nelson Consultant Azane, Inc. Bethesda, MD, USA Missoula, MT, USA Cognizant Committees The chairperson of Refrigerant Committee also served as ex-officio members: Karim Amrane REF Committee AHRI Bethesda, MD, USA i © 2017 ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE’s prior written permission. HISTORY of REVISION / REAFFIRMATION / WITHDRAWAL
    [Show full text]
  • Investigating Applicability of Evaporative Cooling Systems for Thermal Comfort of Poultry Birds in Pakistan
    applied sciences Article Investigating Applicability of Evaporative Cooling Systems for Thermal Comfort of Poultry Birds in Pakistan Hafiz M. U. Raza 1, Hadeed Ashraf 1, Khawar Shahzad 1, Muhammad Sultan 1,* , Takahiko Miyazaki 2,3, Muhammad Usman 4,* , Redmond R. Shamshiri 5 , Yuguang Zhou 6 and Riaz Ahmad 6 1 Department of Agricultural Engineering, Bahauddin Zakariya University, Bosan Road, Multan 60800, Pakistan; [email protected] (H.M.U.R.); [email protected] (H.A.); [email protected] (K.S.) 2 Faculty of Engineering Sciences, Kyushu University, Kasuga-koen 6-1, Kasuga-shi, Fukuoka 816-8580, Japan; [email protected] 3 International Institute for Carbon-Neutral Energy Research (WPI-I2CNER), Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan 4 Institute for Water Resources and Water Supply, Hamburg University of Technology, Am Schwarzenberg-Campus 3, 20173 Hamburg, Germany 5 Leibniz Institute for Agricultural Engineering and Bioeconomy, Max-Eyth-Allee 100, 14469 Potsdam-Bornim, Germany; [email protected] 6 Bioenergy and Environment Science & Technology Laboratory, College of Engineering, China Agricultural University, Beijing 100083, China; [email protected] (Y.Z.); [email protected] (R.A.) * Correspondence: [email protected] (M.S.); [email protected] (M.U.); Tel.: +92-333-610-8888 (M.S.); Fax: +92-61-9210298 (M.S.) Received: 4 June 2020; Accepted: 24 June 2020; Published: 28 June 2020 Abstract: In the 21st century, the poultry sector is a vital concern for the developing economies including Pakistan. The summer conditions of the city of Multan (Pakistan) are not comfortable for poultry birds.
    [Show full text]
  • Thermal Science Cooling Tower Performance Vs. Relative Humidity
    thermal science Cooling Tower Performance vs. Relative Humidity BASIC THEORY AND PRACTICE Total Heat Exchange A mechanical draft cooling tower is a specialized heat exchanger G = mass rate of dry air [lb/min] in which two fluids (air and water) are in direct contact with each L = mass rate of circulating water [lb/min] other to induce the transfer of heat. Le = mass rate of evaporated water [lb/min] THW = temperature of hot water entering tower [°F] Ignoring any negligible amount of sensible heat exchange that TCW = temperature of cold water leaving tower [°F] hin = enthalpy of air entering [Btu/lb/dry air] may occur through the walls (casing) of the cooling tower, the heat hout = enthalpy of air leaving [Btu/lb/dry air] gained by the air must equal the heat lost by the water. This is Cp = specific heat of water = 4.18 [Btu/lb-°F] an enthalpy driven process. Enthalpy is the internal energy plus Win = humidity ratio of air entering [lb water/lb dry air] the product of pressure and volume. When a process occurs at Wout = humidity ratio of air leaving [lb water/lb dry air] constant pressure (atmospheric for cooling towers), the heat In order to know how much heat the air flowing through a cooling absorbed in the air is directly correlated to the change in enthalpy. tower can absorb, the enthalpy of the air entering the tower must This is shown in Equation 1. be known. This is shown on the psychrometric chart Figure 1. G (hout - hin) = L x Cp (THW - 32°) - Cp (L - Le)(TCW - 32°) (1) The lines of constant enthalpy are close to parallel to the lines of constant wet bulb.
    [Show full text]
  • Recommended Qualification Test Procedure for Solar Absorber.Pdf
    Date: 2004-09-10 Editor Bo Carlsson1 IEA Solar Heating and Cooling Program Task 27 Performance of Solar Façade Components Project: Service life prediction tools for Solar Collectors Recommended qualification test procedure for solar absorber surface durability 1 Address: SP Swedish National Testing and Research Institute, P.O.Box 857, SE-50115 Borås, e-mail: [email protected] Contents Page Foreword.............................................................................................................................................................iv Introduktion .........................................................................................................................................................v 1 Scope ......................................................................................................................................................1 2 Normative references ............................................................................................................................1 3 Terms and definitions ...........................................................................................................................2 4 Requirements and classification..........................................................................................................3 5 Test methods for assessing material properties as measure of absorber performance...............4 5.1 Sampling and preparation of test specimens.....................................................................................4
    [Show full text]
  • Evaluation of the Effect of Relative Humidity of Air on the Coefficients of Critical Flow Venturi Nozzles
    Evaluation of the Effect of Relative Humidity of Air on the Coefficients of Critical Flow Venturi Nozzles K. Chahine and M. Ballico National Measurement Institute, Australia P O Box 264, Lindfield, NSW 2070, Australia [email protected] Abstract atmospheric pressures. To establish stable sonic conditions in the nozzle, the down-stream end of the nozzle is usually connected to a high-capacity vacuum At NMIA, volumetric standards such as Brooks pump, with the up-stream end connected to the meter- or bell provers are used to calibrate critical flow Venturi under-test. During calibration the test-flowmeter draws nozzles or “sonic nozzles”. These nozzles, which are air from the laboratory at or near atmospheric pressures extremely stable, are used by both NMIA and Australian and temperature, and with relative humidity varying accredited laboratories to establish continuous flows for between 40% and 60%. The mass flowrate produced by the calibration of gas flow meters. For operational the nozzles is calculated based on the calibrated values of reasons, sonic nozzles are generally calibrated using dry the nozzle coefficient, the measured up-stream pressure air but later used with standard atmospheric air at various and the density calculated from the air temperature, humidity levels either drawn or blown through the meter- pressure and humidity [2]. under-test. Although the accepted theoretical calculations for determining the mass flow through a sonic nozzle At present, any effect of the relative humidity on the incorporate corrections for the resulting change in air nozzle coefficients is considered as negligible, as various density, as laboratories seek to reduce uncertainties the authors have estimated the systematic error at 0.02% for validity of this assumption warrants further examination.
    [Show full text]
  • Investigating Absorption Refrigerator Fires (Part I)
    Orion P. Keifer Peter D. Layson Charles A. Wensley Investigating Absorption Refrigerator Fires (Part I) ATLANTIC BEACH, FLORIDA—In today’s recreational vehicles (RV), the then expels it when perco- most common refrigerator uses absorption refrigeration technology, lated in the boiler. It is this primarily because this type of system can operate on multiple sources action of the water which of power, including propane when electrical power is unavailable. makes the ammonia flow. These refrigerators have been under intense scrutiny in recent years The hydrogen in the re- due to numerous reported fires, apparently starting in the area of the frigeration coil maintains absorption refrigerator. Both the Dometic Corporation and Norcold a positive pressure of ap- Incorporated, two manufacturers of RV refrigerators, have been re- proximately 300-375 PSI quired by the National Highway and Traffic Safety Administration (2.07-2.59 MPa) when (NHTSA) to recall certain models of refrigerators which have been not in operation and, due identified as capable of failing in a fire mode. In summary, the three to its low partial pressure, NHTSA recalls indicate a fatigue crack may develop in the boiler tube promotes the evaporation of the cooling unit which may release sufficient pressurized flammable of the liquid ammonia. It coolant solution into an area where an ignition source is present. The should be noted that unlike NHTSA Recall Campaign ID Numbers are 06E076000 for Dometic conventional refrigeration (926,877 affected units), and 02E019000 (28,144 affected units) and systems which extensively 02E045000 (8,419 affected units) for Norcold. use copper due to its high thermal conductivity, the Applications Engineering Group, Inc.
    [Show full text]
  • Solar Air-Conditioning and Refrigeration - Achievements and Challenges
    Solar air-conditioning and refrigeration - achievements and challenges Hans-Martin Henning Fraunhofer-Institut für Solare Energiesysteme ISE, Freiburg/Germany EuroSun 2010 September 28 – October 2, 2010 Graz - AUSTRIA © Fraunhofer ISE Outline Components and systems Achievements Solar thermal versus PV? Challenges and conclusion © Fraunhofer ISE Components and systems Achievements Solar thermal versus PV? Challenges and conclusion © Fraunhofer ISE Overall approach to energy efficient buildings Assure indoor comfort with a minimum energy demand 1. Reduction of energy demand Building envelope; ventilation 2. Use of heat sinks (sources) in Ground; outside air (T, x) the environment directly or indirectly; storage mass 3. Efficient conversion chains HVAC; combined heat, (minimize exergy losses) (cooling) & power (CH(C)P); networks; auxiliary energy 4. (Fractional) covering of the Solar thermal; PV; (biomass) remaining demand using renewable energies © Fraunhofer ISE Solar thermal cooling - basic principle Basic systems categories Closed cycles (chillers): chilled water Open sorption cycles: direct treatment of fresh air (temperature, humidity) © Fraunhofer ISE Open cycles – desiccant air handling units Solid sorption Liquid sorption Desiccant wheels Packed bed Coated heat exchangers Plate heat exchanger Silica gel or LiCl-matrix, future zeolite LiCl-solution: Thermochemical storage possible ECOS (Fraunhofer ISE) in TASK 38 © Fraunhofer ISE Closed cycles – water chillers or ice production Liquid sorption: Ammonia-water or Water-LiBr (single-effect or double-effect) Solid sorption: silica gel – water, zeolite-water Ejector systems Thermo-mechanical systems Turbo Expander/Compressor AC-Sun, Denmark in TASK 38 © Fraunhofer ISE System overview Driving Collector type System type temperature Low Open cycle: direct air treatment (60-90°C) Closed cycle: high temperature cooling system (e.g.
    [Show full text]
  • Psychrometrics Outline
    Psychrometrics Outline • What is psychrometrics? • Psychrometrics in daily life and food industry • Psychrometric chart – Dry bulb temperature, wet bulb temperature, absolute humidity, relative humidity, specific volume, enthalpy – Dew point temperature • Mixing two streams of air • Heating of air and using it to dry a product 2 Psychrometrics • Psychrometrics is the study of properties of mixtures of air and water vapor • Water vapor – Superheated steam (unsaturated steam) at low pressure – Superheated steam tables are on page 817 of textbook – Properties of dry air are on page 818 of textbook – Psychrometric charts are on page 819 & 820 of textbook • What are these properties of interest and why do we need to know these properties? 3 Psychrometrics in Daily Life • Sea breeze and land breeze – When and why do we get them? • How do thunderstorms, hurricanes, and tornadoes form? • What are dew, fog, mist, and frost and when do they form? • When and why does the windshield of a car fog up? – How do you de-fog it? Is it better to blow hot air or cold air? Why? • Why do you feel dry in a heated room? – Is the moisture content of hot air lower than that of cold air? • How does a fan provide relief from sweating? • How does an air conditioner provide relief from sweating? • When does a soda can “sweat”? • When and why do we “see” our breath? • Do sailboats perform better at high or low relative humidity? Key factors: Temperature, Pressure, and Moisture Content of Air 4 Do Sailboats Perform Better at low or High RH? • Does dry air or moist air provide more thrust against the sail? • Which is denser – humid air or dry air? – Avogadro’s law: At the same temperature and pressure, the no.
    [Show full text]
  • A Review on Solar Powered Refrigeration and the Various Cooling Thermal Energy Storage (CTES) Systems
    International Journal of Engineering Research & Technology (IJERT) ISSN: 2278-0181 Vol. 2 Issue 2, February- 2013 A review on Solar Powered Refrigeration and the Various Cooling Thermal Energy Storage (CTES) Systems 1*Abhishek Sinha and 2 S. R Karale rd 1* Student, III Semester, M.Tech.Heat Power Engineering, 2 Professor Mechanical Engineering Department, G.H Raisoni College of Engineering, Nagpur-440016, India Abstract In this paper, a review has been conducted on various types of methods which are available for utilizing solar energy for refrigeration purposes. Solar refrigeration methods such as Solar Electric Method, Solar Mechanical Method and Solar Thermal Methods have been discussed. In solar thermal methods, various methods like Desiccant Refrigeration, Absorption Refrigeration and Adsorption Refrigeration has been discussed. All the methods have been assesed economically and environmentally and their operating characteristics have been compared to establish the best possible method for solar refrigeration. Also, the various available technologies for Cooling Thermal Energy Storage (CTES) have been discussed in this paper. Methods like Chilled Water Storage (CWS) and Ice Thermal Storage (ITS) have been compared and their advantages and disadvantages have been IJERTdiscussed.IJERT The results of the review reveal Solar Electric Method as the most promising method for solar refrigeration over the other methods. As far as CTES systems are concerned, ITS has advantage over other methods based on storage volume capability, but it has a comparatively lower COP than other available techniques. Keywords: Solar powered refrigeration, Solar Electric Method, Solar Mechanical Method, Solar Thermal Method, CTES system, Chilled Water Storage (CWS) system, ice TES systems, etc.
    [Show full text]
  • Guide for Air Conditioning, Refrigeration, and Help the Student
    DOCUMENT RESUME ED 251 645 CE 040 232 AUTHOR Henderson, William Edward, Jr., Ed. TITLE Art::culated, Performance-Based Instruction Objectives Guide for Air Conditioning, Refrigeration, and Heating. Volume II(Second Year). INSTITUTION Greenville County School District, Greenville, S.C.; Greenville Technical Coll., S. PUB DATE Oct 84 NOTE 374p.; Prepared by the Articulation Program Task Force Committee for Air Conditioning, Refrigeration, and Heating. PUB TYPE Guides Clasrroom Use Guides (For Teachers) (052) EDRS PRICE MF01/PC15 Plus Postage. DESCRIPTO. *Air Conditioning; Behavioral Objectives; Competency Based Education; Curriculum Guides; *Equipment Maintenance; Fuels; Jrade 12; *Heating; High Schools; Job Skills; Le.,zning Activities; *Refrigeration; Secondary Education; Solar Energy; Trade and Industrial Education; Units of Study; *Ventilation ABSTRACT This articulation guide contains 17 units of instruction for the second year of a two-year vocational program designed to prepare the high school graduate to install, maintain, and repair various types of residential and commercial heating, air conditioning, and refrigeration equipment. The units are designed to help the student to expand and apply the basic knowledge already mastered and to learn new principles and techniques and to prepare him/her for entry-level work as an apprentice. The seventeen units cover aid conditioning calculations (psychrometrics,residential heat loss and heat gain, duct design and sizing and air treatment); troubleshooting and servicing residential air conditioners; commercial refrigeration; commercial air conditioning; heating systems (electrical resistance heating, heat pumps, gas heating, oil heating, hydronics, solar heating systems); automotive air conditioner maintenance/repair; estimating and planning heating, ventilation, and air conditioning jobs; customer relations; and shop projects.
    [Show full text]
  • Model 1830, 1850 & 1850W Dehumidifier Owner's Manual
    Model 1830, 1850 & 1850W Dehumidifier Owner’s Manual PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER Installed by: _________________________________ Installer Phone: _______________________ Date Installed: _______________ ON/OFF button Up/Down Dehumidifer Control Outlet used to turn buttons used to dehumidifier on change humidity and off setting MODE button used for optional ventilation feature Inlet Filter Access Drain Power Door Switch 90-1874 WHOLE HOME Dehumidification The Aprilaire® Dehumidifier controls the humidity level in your entire home. A powerful blower inside the dehumidifier draws air into the cabinet, filters the air and removes moisture, then discharges the dry air into the HVAC system or dedicated area of the home. Inside the cabinet, a sealed refrigeration system removes moisture by moving the air through a series of tubes and fins that are kept colder than the dew point of the incoming air. The dew point is the temperature at which moisture in the air will condense, much like what occurs on the outside of a cold glass on a hot summer day. The condensed moisture drips into the dehumidifier drain pan to a drain tube routed to the nearest floor drain or condensate pump. After the moisture is removed, the air moves through a second coil where it is reheated before being sent back into the home. The air leaving the dehumidifier will be warmer and drier than the air entering the dehumidifier. SETTING THE DESIRED HUMIDITY LEVEL The dehumidifier on-board control will display the humidity setting when not running, and ENERGY SavinGS TIPS displays the measured humidity when running. Energy Savings Tip #1: Adjust the humidity setting to be as high as is comfortable to reduce dehumidifier run time.
    [Show full text]