2018 Full Line Catalog Products to Support Dive Shop Operations Table of Contents

Total Page:16

File Type:pdf, Size:1020Kb

2018 Full Line Catalog Products to Support Dive Shop Operations Table of Contents 2018 FULL LINE CATALOG PRODUCTS TO SUPPORT DIVE SHOP OPERATIONS TABLE OF CONTENTS 3 6 8 TEST EQUIPMENT REGULATOR SERVICE & Flowbenches, ACCESSORIES MAINTENANCE workstations, test Regulator, BC and Tools, O-rings, chambers and other console hoses, chemicals and products used in swivels, adapters and equipment used testing regulators, dive related items. for the service and computers and other maintenance of dive related items. regulators, tanks and other dive equipment. 15 17 19 AIR FILTRATION COMPRESSORS TANK FILLING Filters, towers, bulk Small to medium Whips, fill filter chemicals sized breathing attachments and and related control air compressors, adapters for filling hardware for compressor oils and SCUBA, DIN, SCBA breathing air filtration related accessories. and many other tank/ systems. valve styles. 22 28 30 COMPRESSED GAS PAINTBALL MIXED GAS / HARDWARE Whips, adapters and NITROX / OXYGEN Air station hardware, accessories for filling Hardware, chemicals regulators, valves and servicing paint and tools used and fittings for ball tanks and related for the creation, the storage and equipment. handling and analysis distributions of High of mixed gas, Nitrox Pressure Air. and Oxygen. SALES INFORMATION [email protected] 512.240.6644 • 800.558.1811 voice • 512.240.6645 fax MAILING ADDRESS 4674 Priem Lane, Suite 402 • Pflugerville, TX 78660 ANY AND ALL INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE. ALL RIGHTS RESERVED. www.global-mfg.com 2 | TABLE OF CONTENTS TEST EQUIPMENT and stability, and systemic air rubber cup adapter which 48250 Compact Deluxe FLOWBENCHES tightness. Air flow rates through replaces the mouthpiece. First Flowbench with Double tank valves or gas manifolds stage intermediate pressure is Magnehelic Our top-of-the-line analyzer is can also be determined. To sampled through the BC hose. 48251 Compact Deluxe capable of testing all functional aid in the fine tuning of today’s New for 2017: Each flowbench Flowbench with Magnehelic parameters of modern scuba sensitive regulators, breathing now has motor protection circuit and Manometer regulators including air flow rate. effort readings can be examined which removes power to the 48260 Compact Deluxe This user-friendly machine can on an expanded scale at the vacuum motor after several Flowbench with Double quickly evaluate the following flip of a switch. Values to minutes of inactivity. This helps Magnehelic, European Version regulator functions: Air flow rates 0.1” of water column can be prevent motor failures when the (up to 30 cu. ft./min.), inhalation achieved. No dismantling of motor has been inadvertently / exhalation breathing efforts regulators is required prior to left on. See data sheet for full at both initiation and during air testing: Air from the second specifications. flow, first stage intermediate stage is injected directly into pressure, lockup repeatability the machine through a simple, 48250 48251 WWW.GLOBAL-MFG.COM • [email protected] • 512.240.6644 • 800.558.1811 TEST EQUIPMENT | 3 TEST EQUIPMENT 48400 Standard Regulator / 48155 Benchtop Breathing Valve Workstation: Workstations Effort Tester: A simple, easy-to- provide controlled air pressure to use device for quickly testing the a test stand where the functions initial inhalation and exhalation of dive regulators can be checked effort of any regulator’s second at sea level conditions. Regulators stage. Breathing efforts are read to be examined are yoked to the directly from a Magnehelic gauge test stand valve; where inter- reading ±2 inches water column. stage pressure is transmitted 48160 Benchtop Intermediate to the instrumentation via an Pressure Tester: Housed in a adapter coupled to the BC handsome plastic case is a 300 hose. First stage intermediate psi pressure gauge with 1% pressure, lockup repeatability accuracy. A series of coupler and stability, and systemic air adapters allow for attachment of tightness can then be evaluated. different brands of BC hoses. A simple probe is then attached to the 2nd stage outlet while 48165 Digital Benchtop manual breathing is performed, Regulator Tester with the initial inhalation/exhalation Magnehelic: This compact test effort (cracking resistance) can apparatus allows several very be read with high precision important regulator functions on a Magnehelic gauge. A to be examined with highly unique “reading lock” device accurate instrumentation. momentarily freezes the This tester can check the breathing effort readings on the intermediate pressure, lockup, 48400 gauge, so that values accurate staging integrity, and initial to 0.1” of water column can be inhalation / exhalation of any obtained! dive regulator without any major disassembly. First stage 48100 Portable Regulator operation can be examined by This unique device Tester: merely attaching the BC hose can be used to test SCUBA to the tester. To connect the regulators for inhalation / various types of BC hoses, three exhalation effort plus first stage special adapters are provided. intermediate pressure and Instrumentation features a 4.0” lockup stability. All tests can be diameter breathing effort gauge done without dismantling the (2” scale) and a digital readout regulator. Housed in a tackle- of a pressure transducer (300 box like carrying case, the tester psi) for intermediate pressure, has a lift-out tray where parts protected by an overpressure and tools can be carried. This valve. Housed in a robust, compact and portable device aluminum, desktop style case. is ideal for field repairs, charter 120-240 VAC power required. boat operations, classroom demonstrations, or small repair centers which do not require more elaborate equipment. 48100 48155 48160 48165 4 | TEST EQUIPMENT TEST EQUIPMENT 48101 – 43275 - TEST CHAMBERS REGULATOR REGULATOR The current industry standard for testing the water-tight PROBE INTERMEDIATE integrity, accuracy, and overall function of depth gauges, watches, dive computers, and certain underwater photographic A 33” plastic tube and special PRESSURE gear. Each chamber is constructed with a rugged steel rubber probe to use with QUICK-TESTER structure. The cogged lid with clear acrylic lens is designed for Magnehelic Gauges for testing strength and ease of operation. Standard “Depth” chambers the initial breathing effort of dive This 2.5” gauge attaches directly have gauges with 1% accuracy. While, “Instrument” chambers regulators. The probe has two to the buoyancy compensator have high accuracy, 0.25% accuracy gauges. See data sheet for different sized ends. The small hose for fast checking the more details end will insert directly into many intermediate pressure of any 48300 Depth Test Chamber: Reads to 230 feet of fresh water mouthpieces. If this fails, remove regulator first stage without with 1% accuracy. the mouthpiece and slip the dismantling the unit. A manual large end over the bare flange. bleeder vent allows easy cycling 48305 Extended Range Depth Test Chamber: Reads to 370 of the first stage to test the feet of fresh water with 1% accuracy. consistency of lockup. The 48310 Instrument Test Chamber: Reads to 300 feet of salt regulators second stage (or water with 0.25% accuracy. octopus) acts as an overpressure valve in case of serious staging 48320 Extended Range Instrument Test Chamber: Reads to failures. Great for field service, 450 feet of salt water with 0.25% accuracy. charter boats, and class demos. 48320-DRO Instrument Test Chamber with Digital Readout: Equipped with a high accuracy pressure transducer, this unit has less than - 0.25% accuracy on a range up to 450 feet of salt water. No more worries about converting units as the integral touch screen displays pressure/depth in the following units: pounds per square inch (psi), feet of fresh water, meters of fresh 48101 water, feet of sea water, meters of sea water, BAR and kilopascals. The touch screen display shows date and time making it easy to record test data. A handy countdown timer is included. This 43300 – can be very helpful for leak testing where a product has to be MAGNEHELIC submerged at ‘depth’ for a given amount of time. 48301 Chamber Bulkhead Air Supply: Connects any standard GAUGE ±5 yoke style tank to the Bulkhead Air Shunt. INCH SCALE 57136 Hoseless Computer Adapter: A combination of a short high pressure regulator hose that accepts the Considered the standard computers transducer and extends it into the chambers water instrument for measuring bath allowing the testing of hoseless computers in Global’s the breathing effort of dive Instrument Test Chambers. regulators, this Magnehelic 43275 Gauge has dual, 5-inch scales to 48320-AUTO An advanced version of our Instrument Test sense both positive (exhalation) Chamber: Computerized control allows for complete dive and negative (inhalation) profiles to be programmed. Pressure is transmitted through a pressures. Breathing resistance 0.25% accuracy pressure transducer. See data sheet for more is measured in inches of details. water column, equivocally the respiratory effort required to draw water one inch up a straw! Used with #48101 probe (not incl.), this is an essential addition to the dive shop repair department. Order #43302 for ±2 inch scale. 48310 48320-DRO 57136 43300 48301 48320-AUTO WWW.GLOBAL-MFG.COM • [email protected] • 512.240.6644 • 800.558.1811 TEST EQUIPMENT | 5 REGULATOR ACCESSORIES REGULATOR REGULATOR HOSES SWIVELS Standard Low Pressure Breathing AND ADAPTERS Air Hoses are 5/16” ID while BC Standard 90° configuration hoses are 1/4” ID. Breathing swivels. Air and BC hoses are rated to BC HOSE 400 psi working pressure. All 57140 3/8-24 threads in and 57140... hoses are black with an option of out. 3,000 psi service yellow, available in 5/16” ID. All 57155 1/2-20 threads in and Global Low Pressure Breathing out, 400 psi service Air and BC hoses are assembled and tested in house. Each hose 57190 7/16-20 threads in and is pressurized to 400 psi and out, 3,000 psi service checked for leaks. Non-standard 57195 3/8-24 male to 7/16-20 fittings, such as 1/4 Female BREATHING AIR HOSE female threads, 3,000 psi service NPT are available.
Recommended publications
  • Rebreathers Open Inspiration Fully Closed Rebreather What Is It Like? Text & Photos by Peter Symes Diving Rebreathers Why Bother?
    WWW.AQUALUNG.COM Dräger Ray semiclosed rebreather. Behind, an Rebreathers open Inspiration fully closed rebreather What is it like? WWW.AMBIENTPRESSUREDIVING.COM Text & photos by Peter Symes Diving Rebreathers Why bother? Rebreathers look cool, glitzy, tech- they provide for a much differ- nical and heralded as the future of ent and richer diving experience, which, in the first place, is why we go in diving, right? We read a lot about the water ourselves rather than watch- their impressive performances con- ing dive movies on Animal Planet from cerning duration of dives, gas econ- the comfort of our reclining chair at home. omy, extended no deco limits and However, as we all know, there is no such thing as a free lunch in diving either. There is what not. But isn’t it a bit like watch- a trade-off, and you will have to consider if it the underwater realm so you can have an ing Jeremy Clarkson from BBC’s car is still worth your while despite this. enriching experience by witnessing, first program, Top Gear, whiz around in It is not merely a matter of comparing hand, this magic realm. So, as far as I am fancy Ferraris and Aston Martins with technical matters, performance and param- concerned, if someone invented human eters when pitting rebreathers against the gills and a thin hide to cover and keep me a goofy, happy grin on his face and open circuits (regulators and tanks). It is warm, my twin-set would surely be left to rust reeling off a string of excited super- easy to be blinded by dazzling numbers and in the attic for good.
    [Show full text]
  • Portable Oxygen Concentrator Therapy Guide Guidance for Patients Requiring Long-Term, Supplemental Oxygen Solutions
    Portable Oxygen Concentrator Therapy Guide Guidance for patients requiring long-term, supplemental oxygen solutions. Table of Contents Part One: Oxygen Therapy 101 Part Two: Oxygen Concentrators Part Three: Portable Oxygen Concentrators Part Four: Which Oxygen Concentrator is Right For You? Confused or overwhelmed? Let us help you! Our Product Specialists are standing by to answer questions and offer tips.(800) 515-8049 INTRODUCTION 3 Welcome! OxygenDirect is pleased to provide this educational guide for current and potential patients to understand the benefits of oxygen therapy—and specifically portable oxygen concentrators. We intend to expand patients’ knowledge and appreciation of advancements in technology that are now available. This document is designed to complement the information provided by a doctor or healthcare provider when discussing oxygen therapy options. Who is OxygenDirect? OxygenDirect is dedicated to helping oxygen therapy patients breathe easier without interfering with lifestyles and daily activities. We offer a wide selection of portable and home oxygen products and accessories, plus a diverse range of CPAP machines and accessories. Our OxygenDirect Product Specialists can help evaluate patients’ oxygen needs and varying product features to ultimately arrive at a product that perfectly fits a wide range of lifestyles and budgets. Disclaimer: The information contained in this document is general in nature and is not intended to be a substitute for professional medical advice, diagnosis, or treatment. Always seek the advice of your physician or other qualified health providers with any questions you may have regarding a breathing/medical condition. Never disregard professional medical advice or delay in seeking it because of something you have read on this document.
    [Show full text]
  • COVID-19 Basic Manual on Oxygen Supply Systems in Emts and AMCS
    Emergency Medical Teams Operational Support COVID-19 Basic Manual on oxygen supply systems in EMTs and AMCS Preliminary Document - Version 2.1, 18 February 2021 PAN AMERICAN HEALTH ORGANIZATION (PAHO/WHO) | www.paho.org Contents 1. Introduction.....................................................................................3 2. Basic concepts ..................................................................................4 2.1 Medical gases .............................................................................4 2.2 Medical parameters of O2 ..................................................................4 2.3 Regulation.................................................................................5 3. Sources of oxygen for medical use...............................................................6 4. Oxygen systems for medical use.................................................................9 4.1 Individual O2 systems .....................................................................11 4.1.1 Individual cylinders...............................................................11 4.1.2 Individual concentrators ..........................................................12 4.2 Centralized O2 systems ...................................................................12 4.3 Components .............................................................................13 4.3.1 Pipes and fittings..................................................................13 4.3.2 Sockets and connectors...........................................................15
    [Show full text]
  • Oxygen Therapy Orders
    Welcome to the Specialized Medical Services Respiratory training webinar series! SMS is your Long Term Care (LTC) facility single source for oxygen, medical equipment, respiratory care services and supplies nationwide. This respiratory module is for reference purposes and designed to provide a basic understanding of Oxygen Equipment commonly used in Long Term Care. It is still important to consult your local respiratory professional and follow physician orders when applying respiratory treatment. At the completion of each training module, a short post test will be offered, and with successful completion, a training certificate recognizing your participation for your records. Oxygen Equipment Webinar Training Session Training Objectives • Recognize the different types of oxygen equipment • Understand how to operate each piece of equipment • Select the right system for your patients’ needs • Learn common troubleshooting techniques 3 Primary System Types 1. Compressed gas (cylinder/tank) 2. Oxygen concentrators 3. Liquid oxygen Compressed Gas Cylinders • Compressed Oxygen • Stored under pressure in a vessel or tank • Variety of tank sizes Oxygen Concentrators • Electrically operated devices • Draw in air from the surrounding room • Filter out the nitrogen • Compress the remaining oxygen for patient use • Deliver medical grade oxygen Liquid Oxygen • Compressed and cooled • Converts oxygen to a liquid state • Much larger storage ratio of oxygen Types of Compressed Gas Cylinders “Walk O2 About” Aluminum E Standard Aluminum E With Integrated
    [Show full text]
  • Resting Oxygen Consumption Rates in Divers Using Diver Propulsion Devices Adam J
    University of South Florida Scholar Commons Graduate Theses and Dissertations Graduate School 10-29-2008 Resting Oxygen Consumption Rates in Divers Using Diver Propulsion Devices Adam J. Smith University of South Florida Follow this and additional works at: https://scholarcommons.usf.edu/etd Part of the American Studies Commons Scholar Commons Citation Smith, Adam J., "Resting Oxygen Consumption Rates in Divers Using Diver Propulsion Devices" (2008). Graduate Theses and Dissertations. https://scholarcommons.usf.edu/etd/502 This Thesis is brought to you for free and open access by the Graduate School at Scholar Commons. It has been accepted for inclusion in Graduate Theses and Dissertations by an authorized administrator of Scholar Commons. For more information, please contact [email protected]. RestingOxygenConsumptionRatesinDiversUsingDiverPropulsionDevices by AdamJ.Smith Athesissubmittedinpartialfulfillment oftherequirementsforthedegreeof MasterofScienceinBiomedicalEngineering DepartmentofChemical&BiomedicalEngineering CollegeofEngineering UniversityofSouthFlorida MajorProfessor:WilliamE.LeeIII,Ph.D. JohnR.Clarke,Ph.D. RolandD.Shytle,Ph.D. DateofApproval: October29,2008 Keywords:OxygenConsumption,Diving,Rebreather,PropagationofError, InjectionRate,Nitrox,Semiclosed ©Copyright2008,AdamJ.Smith Dedication Thisthesisisdedicatedtomyfamilywhohavelovedandsupportedme throughoutmystudies.Iamblessedtohavesuchgreatrolemodelsasmy parents. Acknowledgments First,IwouldliketoexpressthedeepestofgratitudetoDr.JohnClarke.
    [Show full text]
  • Mini Quantum SG User Manual
    mini Quantum SG User Manual Safety notes The most important words are: Danger! Refers to an immediate danger, which can lead to serious injuries as well as to death. Warning! Refers to a potential danger, which can lead to serious injuries as well as to death. Attention! Refers to a potential danger, which can lead to small injuries. This term is also used as warning to uncertain use. The above-mentioned words have to be followed carefully to have fun while diving with the Submatix Quantum rebreather. Warning! The Submatix Quantum rebreather has to be maintained according to the regulations mentioned in this manual. In case of repairs only original Submatix parts must be used. The use of other parts can cause a malfunction of the Quantum rebreather and it can lead to serious injuries or death! Quantum EXP SG Manual Page 2 The servicing of the Submatix Quantum rebreather must be carried out regularly and only by authorised Submatix repair facility. The owner and the service department must keep a record of all maintenance work and repairs. The chapters about servicing intervals and works, concluded in this manual, have to be observed carefully. Only SUBMATIX trained repair technicians are permitted to carry out service and repair on Quantum SG. Use only authentic SUBMATIX parts in the maintenance and repair of the SUBMATIX Liability for function and/or damages In any case the owner and/or user will be liable for the function of the unit when the unit is and/or was serviced or overhauled improperly by persons, who do not belong to the Submatix service team or who are not trained in special for the service of the unit.
    [Show full text]
  • Using Oxygen at Home
    Using Oxygen at Home #338 ©(2005, 2009, 2015) The Emily Center, Phoenix Children’s Hospital 1 Contents 3 Important information 3 Who to call for help 5 The respiratory system 6 How to look at breathing problems 8 What is oxygen? 9 Supplies and equipment 13 To move the regulator from one portable tank to another 17 Where to keep the oxygen 18 How to give oxygen through a nasal cannula 18 How to put on the nasal cannula 19 Skin care 19 If your child pulls the cannula off 19 How to give oxygen through an oxygen mask 20 Safety 20 Fire safety 22 Check your oxygen system often 22 Use your oxygen system safely 24 Cleaning your child’s oxygen system 24 How to clean nasal cannulas 25 Humidifier bottle 25 Getting out of the house 26 Before you travel overnight or far away 26 Plan 26 Pack 27 Travel by car, van or truck 27 Travel by bus, train, ship, or plane 28 Some questions parents ask about oxygen 30 Now that you’ve read this 2 ©(2005, 2009, 2015) The Emily Center, Phoenix Children’s Hospital Important information Your child’s prescribed oxygen flow is _____________________________ Do not give your child less oxygen than the doctor ordered. You can hurt your child by turning the oxygen down without orders from the doctor. You child’s oxygen is worn ______________________________________ There may be times when your child needs more oxygen. Some children need more oxygen when they eat, play, or have a cold. You may turn up the oxygen flow to __________________________ If your child needs a higher amount of oxygen for at least 24 hours, tell your child’s doctor.
    [Show full text]
  • Poseidon MKVI User Manual Chapter 1 Page 1
    Poseidon MKVI User Manual Chapter 1 Page 1 POSEIDON MKVI USER MANUAL Poseidon MKVI User Manual Chapter 1 Page i Table of Contents Table of Contents ...................................................................................................i Cylinders and regulators ......................................................................................10 Conventions Used in this Guide ............................................................................ iv Filling the cylinders .......................................................................................11 Preface .................................................................................................................v Conformance With CE Requirements .................................................................... vi Part 2 – Assembly 1. Stabjacket / BCD / Wing. ................................................................................13 Chapter 1 - Preparation & Assembly 2. Tank band. ......................................................................................................14 3. Counter lungs to BCD / Harness. ....................................................................15 Part 1 – Preparation 4. Rear CC hoses to counter lung. ......................................................................16 5. Rear CC loop hoses. .......................................................................................18 An Overview of the Poseidon MKVI ........................................................................1 6. Attaching
    [Show full text]
  • Oxygen Therapy
    Oxygen Therapy: Overview • Application • Devices New Jersey Respiratory Associates Nurse Competency Program Oxygen Therapy Instruction Check Sheet Demonstrate: _____ FIO2 concentration delivery methods: Nasal Cannula Venturi Mask Simple Mask Non-Rebreather mask _____ Adequate liter flow for: Nasal Cannula Venturi Mask Simple Mask Non-Rebreather mask Explain: _____ The danger of high concentrations of oxygen with residents with known history of COPD _____ Which devices can only be used with oxygen tanks _____ Emergency Application of Oxygen Nurse: ______________________________________ Instructor: ____________________________________ Date: ________________________________________ Oxygen Therapy Overview Purpose: To treat hypoxemia, decrease work of breathing and decrease myocardial work Scope: Patient’s requiring supplemental 02 therapy due to respiratory or cardiac insufficiency Procedure: Follow Universal Precautions Verify Medical Doctor order (should include liter flow, type of 02 delivery device if possible) Wash hands and explain procedure to the patient Confirm the patient’s identification from the wristband Gather equipment: o 02 source o Oxygen delivery device o Humidifier with sterile water if indicated Connect the humidifier bottle filled with sterile water to the 02 source, making sure all connections are tight Turn on the 02 source and adjust the flowmeter to the prescribed flow Verify the flow of 02 at the patient end of the delivery device Connect the 02 delivery device to the patient Simple masks should be run at 5-10 lpm Non-Rebreather masks should be run at an adequate flow so that the bag doesn’t deflate on the maximal inspiration(at least 6lpm) Venturi mask flow should be advised as per Venturi device indicating desired F102 New Jersey Respiratory Associates Nurse Competency Program Oxygen Therapy Emergency Application of Oxygen General Patients 1.
    [Show full text]
  • Complete Guide to Oxygen Therapy Completeguideto5 Complete Oxygen Guide Therapy To
    Complete Guide To Oxygen Therapy CompleteGuideto5 to Therapy Guide Oxygen Complete OxygenTherapy5 Whatisoxygentherapy?6 Stationaryoxygentherapysystems10 Portableoxygentherapysystems14 rvln ihOye Therapy with Oxygen Traveling Portablecompressedgascylinders15 Othercomponentsforyouroxygentherapysystem17 Safetytipsforusingyouroxygentherapysystem19 Benefitsofoxygentherapy20 Howwilloxygentherapyaffectmylifestyle?21 Payingfor 22 OxygenTherapy22 Medicare23 Otherwaystopay25 FrequentlyAskedQuestions26 2 3 01 Complete Guide to Oxygen Therapy What is oxygen therapy? order a blood test to check the oxygen content of your blood. You to Therapy Guide Oxygen Complete qualify for oxygen therapy under the following conditions: If you have been diagnosed with a disease that makes it hard to breathe, such as chronic obstructive pulmonary disease (COPD) or ■ If your oxygen saturation (SaO2) level on room air (ie, pulmonary fibrosis, you may have symptoms such as: without oxygen) at rest while you’re awake is 88% or less as measured by a pulse oximeter (a small, noninvasive device that ■ Shortness of breath, especially when you walk or exercise; clips onto your finger and measures the amount of oxygen in your blood) or is 55 mm Hg or less as measured by a blood test, ■ Cough; you may qualify for continuous oxygen therapy. (See Paying for ■ Tiredness; Oxygen Therapy for additional requirements.) opeeGieto Therapy Guide Oxygen Complete ■ Headaches; If your SaO2 level on room air at rest while you’re awake is above 88%, your health care provider may check your SaO2: ■ Swollen ankles when you get up in the morning; or – Atrestonroomair; ■ Blue fingertips or lips. – Withexertiononroomair; – With exertion on oxygen; and Symptoms such as these may indicate low oxygen levels in your blood. This condition, called hypoxemia, affects your body in If your SaO2 is 88% or less during these tests, you qualify for several ways.
    [Show full text]
  • Glossary of Rebreather Diving by Jill Heinerth !A !Absolute Pressure – the Total Pressure Imposed by the Depth of Water Plus the Atmospheric Pressure at the Surface
    ! Glossary of Rebreather Diving by Jill Heinerth !A !Absolute pressure – The total pressure imposed by the depth of water plus the atmospheric pressure at the surface. Absorbent pads – Absorbent material placed in a breathing loop; used to soak up moisture caused by condensation !and metabolism. Accumulator – A small chamber that provides a collection vessel to ensure proper gas flow of oxygen to a solenoid !valve. Active-addition – A rebreather gas-addition system that actively injects gas into the breathing loop (such as a !constant-mass flow valve in certain kinds of semiclosed rebreathers). !Atmospheres absolute (ata) – The absolute pressure as measured in atmospheres. Atmosphere (atm) – A unit of pressure equivalent to the mean pressure exerted by the Earth's atmosphere at sea !level, or by 33 fsw, or by 10 msw (equal to 1.0 bar or 14.7 psi). Automatic diluent valve (ADV) – A mechanically-activated valve that adds diluent gas when increasing pressure !associated with descent or lowered volume triggers the device. Axial scrubber – A type of CO2 absorbent canister design. In this design, the gas flows through the canister in a !linear fashion from one end of the canister to the other. !B Backplate – A plate made of stainless steel, aluminum or acrylonitrile butadiene styrene (ABS) plastic which !attaches to a rebreather and allows for the use of a webbed or soft harness system. !Bailout – A failure requiring a dive to be terminated, usually using open-circuit gas. Bailout gas – Tanks carried by the diver to allow for escape from a serious situation, often conducted with open- !circuit technique.
    [Show full text]
  • Who-Unicef Technical Specifications and Guidance for Oxygen Therapy Devices
    WHO-UNICEF TECHNICAL SPECIFICATIONS AND GUIDANCE FOR OXYGEN THERAPY DEVICES WHO MEDICAL DEVICE TECHNICAL SERIES Illustration 4.5 thorpe tube ILLUSTRATION 6.2(portable handheld oximeter) Illustration 3.2 concentrators WHO-UNICEF TECHNICAL SPECIFICATIONS AND GUIDANCE FOR OXYGEN THERAPY DEVICES WHO MEDICAL DEVICE TECHNICAL SERIES WHO-UNICEF technical specifications and guidance for oxygen therapy devices (WHO medical device technical series) ISBN 978-92-4-151691-4 (WHO) © World Health Organization and the United Nations Children’s Fund (UNICEF), 2019 This joint report reflects the activities of the World Health Organization (WHO) and the United Nations Children’s Fund (UNICEF) Some rights reserved. This work is available under the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 IGO licence (CC BY-NC-SA 3.0 IGO; https://creativecommons. org/licenses/by-nc-sa/3.0/igo). Under the terms of this licence, you may copy, redistribute and adapt the work for non-commercial purposes, provided the work is appropriately cited, as indicated below. In any use of this work, there should be no suggestion that WHO or UNICEF endorses any specific organization, products or services. The unauthorized use of the WHO or UNICEF names or logos is not permitted. If you adapt the work, then you must license your work under the same or equivalent Creative Commons licence. If you create a translation of this work, you should add the following disclaimer along with the suggested citation: “This translation was not created by the World Health Organization (WHO) or the United Nations Children’s Fund (UNICEF). Neither WHO nor UNICEF are responsible for the content or accuracy of this translation.
    [Show full text]