Efficient Antenna Systems, Inc. 4.5 Meter Survivor Series Antenna Package Comparison Check Sheet
Total Page:16
File Type:pdf, Size:1020Kb
EASi. Efficient Antenna Systems, Inc. 4.5 Meter Survivor Series Antenna Package Comparison Check Sheet EASi. 4.5 meter AZ/EL Motorized/Fixed antenna package reflector EASi Other Other 12 stamped 16 gauge galvanized steel painted interchangeable panels ____ ____ ____ 12 galvanized steel panel interchangeable braces ____ ____ ____ 12 galvanized steel panel interchangeable radials ____ ____ ____ Stainless steel reflector hardware ____ ____ ____ 4 interchangeable heavy duty aluminum feed arms ____ ____ ____ Damaged panels, radials braces and feed arms can be replaced individually EASi. 4.5 meter galvanized kingpost 14” diameter galvanized .375W A53 center tube with galvanized steel yoke frame ____ ____ ____ Horizontal leg ½” wall 4”x 6” square tubing galvanized ____ ____ ____ Vertical leg 3/8” wall 4”x 4” square tubing galvanized ____ ____ ____ Laser cut for product consistency Optional galvanized rear kicker adapters with adjustable azimuth location positioning ____ ____ ____ Available for special high wind applications ____ ____ ____ Available for load dispersion applications such as I beam frame configuration ____ ____ ____ Can be added to package at a later date ____ ____ ____ EASi. fixed/manual AZ/EL turnbuckle kit for fixed system ____ ____ ____ 1 ½” grade B7 threaded rods on both axis ____ ____ ____ Elevation adjustment tube is 2 ½” square with ¼” wall thickness ____ ____ ____ All EASi. antenna attachment/rotation points use SAE 660 bronze flanged bushings ____ ____ ____ EASi. 90 VDC ODU Control System (30 amp, 120 VAC circuit w/disconnect req. ____ ____ ____ 90 VDC Motor drive outputs ____ ____ ____ Dual speed motor control ____ ____ ____ Integrated heater for temperature/dehydration purposes ____ ____ ____ Environmentally sealed NEMA enclosure ____ ____ ____ EASi Other Other Joyce Dayton 10 ton Azimuth ComDRIVE Package ____ ____ ____ 10 ton machine screw ComDRIVE Dynamic 5500 lbs. Static 20,000 lbs. ____ ____ ____ *Note: Typical standard 36 VDC actuators rated at 1500 dynamic/3000 static Special anti-backlash feature ____ ____ ____ Built in digital tachometer for excellent accuracy ____ ____ ____ *Note: 3 times the resolution per inch compared to standard 36 VDC actuators 1 ½ HP Baldor 90 VDC outdoor rated motor ____ ____ ____ Integrated electrical limit switches ____ ____ ____ Integrated brush heaters ____ ____ ____ Integrated hard stop collars ____ ____ ____ Accordion weather boot ____ ____ ____ System allows for periodic lubrication ____ ____ ____ Joyce Dayton 10 ton Elevation ComDRIVE Package ____ ____ ____ 10 ton machine screw ComDRIVE Dynamic 5500 lbs. /Static 20,000 lbs. ____ ____ ____ *Note: Typical standard 36 VDC actuators rated at 1500 dynamic/3000 static Special anti-backlash feature ____ ____ ____ Built in digital tachometer for excellent accuracy *Note: 3 times the resolution per inch compared to standard 36 VDC actuators 1 ½ HP Baldor 90 VDC outdoor rated motor ____ ____ ____ Integrated electrical limit switches ____ ____ ____ Integrated brush heaters ____ ____ ____ Integrated hard stop collars ____ ____ ____ Accordion weather boot ____ ____ ____ System allows for periodic lubrication via grease zerks ____ ____ ____ EASi. lightning kits Class 1and Class 2 ____ ____ ____ Thompson Lightning Products parts including: ____ ____ ____ 12” x 24” solid aluminum point blunt tip w/adapter ____ ____ ____ Aluminum vertical connector point base ____ ____ ____ Aluminum standard cable ____ ____ ____ All products are UL96 rated ____ ____ ____ Class 1 and 2 requirements sized accordingly ____ ____ ____ L Comm Lightning Protectors ____ ____ ____ DC-3 GHz ____ ____ ____ Bi-directional protection ____ ____ ____ Protector will pass DC ____ ____ ____ Easily replaceable gas tube element ____ ____ ____ Multi-Strike Capability ____ ____ ____ RCI 2000 Programmable Antenna Controller with feed drive option ____ ____ ____ Automatic positioning after programming ____ ____ ____ High resolution sensor processing ____ ____ ____ Dual speed ____ ____ ____ Non-volatile memory ____ ____ ____ Built in current limiting ____ ____ ____ Adapti-drive ____ ____ ____ Software limits on all axis ____ ____ ____ Back up by electrical limit switches and antenna stop collars ____ ____ ____ RS-422 PC control interface option ____ ____ ____ RCI 2000 Embedded controller option ____ ____ ____ Controller option for installation of controller at antenna ____ ____ ____ Programmable Antenna Controller with feed drive option ____ ____ ____ Automatic positioning after programming ____ ____ ____ High resolution sensor processing ____ ____ ____ Dual speed ____ ____ ____ Non-volatile memory ____ ____ ____ Built in current limiting ____ ____ ____ Adapti-drive ____ ____ ____ Software limits on all axis ____ ____ ____ RS-422 PC control interface option ____ ____ ____ Outdoor NEMA enclosure ____ ____ ____ RCI Web Server for RCI Controllers ____ ____ ____ Automatic and manual movement operation ____ ____ ____ Displays system faults and allows fault resets ____ ____ ____ Compatible with most web browsers ____ ____ ____ Configurable IP address for easy network configuration ____ ____ ____ Seavey 4 port motorized C/Ku feed assembly ____ ____ ____ Waveguide bends ____ ____ ____ Factory tuned for C and Ku band performance ____ ____ ____ 24 VDC drive motor ____ ____ ____ 5K positioning pot ____ ____ ____ Waveguide bends to allow installation under protective cover ____ ____ ____ Other feeds and multi-feed systems available for this antenna ____ ____ ____ EASi. Feed cover for Seavey feeds ____ ____ ____ White weather/impact resistant cover ____ ____ ____ Custom Seavey feed attachment brackets ____ ____ ____ Custom anti-intrusion inserts to resist pests ____ ____ ____ Quintech LS4 2150/4x16A Quad 4-Way Active Splitter ____ ____ ____ 950-2150 MHz ____ ____ ____ 4x16 signal splitting with zero loss ____ ____ ____ Redundant power supplies ____ ____ ____ 18-24 VDC ____ ____ ____ 1 RU ____ ____ ____ Norsat 3420 PLL C band LNBs ____ ____ ____ +/-2 kHz stability ____ ____ ____ 20K temperature ____ ____ ____ 62 dB gain(Typical) ____ ____ ____ +12 to +24V ____ ____ ____ Norsat HS1027A PLL Ku Band LNBs ____ ____ ____ +/-2 kHz stability ____ ____ ____ 0.7 dB noise figure ____ ____ ____ 60 dB gain(Typical) ____ ____ ____ +15-+24V Microwave Filter Company 13961 WE TI filters ____ ____ ____ Improved insertion loss performance over traditional filters ____ ____ ____ Improved passband edge roll-off over traditional filters ____ ____ ____ Aluminum body to reduce weight/stress on feed system ____ ____ ____ **5G filters available** ____ ____ ____ EASi. CUSTOM control cable (Availability subject to inventory levels) (UL) PLTC DIR BUR or (UL) ITC or (UL) CM C(UL) US 105’C SUN RES DIR BUR “ROHS II” FT-4 Suitable for wet locations ____ ____ ____ Standards 11.1. UL listed as type PLTC per UL standard 13 ____ ____ ____ 11.2. Cable is UL approved for Sunlight Resistant and Direct Burial ____ ____ ____ 11.3. Cable is suitable for Wet Locations ____ ____ ____ 11.4. All materials used in the this cable are RoHS II and REACH compliant ____ ____ ____ 11.5. Maximum Operating Voltage: 300V RMS ____ ____ ____ 11.6. Made in the USA ____ ____ ____ Commscope 5940R Quad RG 11 cable ____ ____ ____ 75 ohm ____ ____ ____ 14 AWG solid center conductor ____ ____ ____ 14 SOL CCS FPE Foil+60% AL BRD+Foil+40% AL Braid FRPVC ____ ____ ____ Foam PE ____ ____ ____ 5.08 (dB/100ft) attenuation at 1450 MHz ____ ____ ____ Safety Standard cETL ETL ____ ____ ____ CMR Non-Plenum ____ ____ ____ RoHS 2011/65/EU ____ ____ ____ ISO 9001 :2015 ____ ____ ____ 100% sweep tested ____ ____ ____ 15 dB structural return loss @ 1000-3000 MHz ____ ____ ____ EASi. Wiring kits Combination of RG 6 Quad feed motor control cable ____ ____ ____ Feed control cable (UL) PLTC DIR BUR or (UL) ITC or (UL) CM C(UL) ____ ____ ____ US 105’C SUN RES DIR BUR “ROHS II” FT-4 Suitable for wet locations ____ ____ ____ Commscope 5781 RG 6 Quad ____ ____ ____ 75 ohm ____ ____ ____ Bare copper center conductor ____ ____ ____ 18 SOL BC FPE Foil+60% AL BRD+Foil+40% AL BRD FRPVC ____ ____ ____ CMG ____ ____ ____ cETL ETL ____ ____ ____ 7.49 (dB/100ft) attenuation at 1450 MHz ____ ____ ____ RoHS 2011/65/EU ____ ____ ____ ISO 9001 :2015 ____ ____ ____ 15 dB structural return loss @ 1000-3000 MHz ____ ____ ____ Installations of EASi systems including controller programming ____ ____ ____ Assembly of the following to specification: Kingpost ____ ____ ____ Actuators or turnbuckle systems ____ ____ ____ Low voltage wiring of all required outdoor systems EASi supplied ____ ____ ____ Feed assembly with filters and LNBs. ____ ____ ____ Complete reflector assembly with integration to kingpost ____ ____ ____ Low voltage wiring of all required indoor systems EASi supplied ____ ____ ____ Termination of all RF ____ ____ ____ Setup of all hard and soft limits ____ ____ ____ Antenna aiming and/or programming of antenna controller ____ ____ ____ EASi. 4.5 De-Ice Options: Clearsat Vinyl snow shield Walton Kynar snow shield/opt. rain/ice quake/electric or gas heat Walton Tedlar snow shield/opt. rain/ice quake/electric or gas heat Walton Sefar snow shield/opt. rain/ice quake/electric or gas heat RTI active rear mounted systems in multiple configurations Walton rear mounted systems in multiple configurations Gas and or electrical systems may require Walton tech to certify.