
EASi. Efficient Antenna Systems, Inc. 4.5 Meter Survivor Series Antenna Package Comparison Check Sheet EASi. 4.5 meter AZ/EL Motorized/Fixed antenna package reflector EASi Other Other 12 stamped 16 gauge galvanized steel painted interchangeable panels ____ ____ ____ 12 galvanized steel panel interchangeable braces ____ ____ ____ 12 galvanized steel panel interchangeable radials ____ ____ ____ Stainless steel reflector hardware ____ ____ ____ 4 interchangeable heavy duty aluminum feed arms ____ ____ ____ Damaged panels, radials braces and feed arms can be replaced individually EASi. 4.5 meter galvanized kingpost 14” diameter galvanized .375W A53 center tube with galvanized steel yoke frame ____ ____ ____ Horizontal leg ½” wall 4”x 6” square tubing galvanized ____ ____ ____ Vertical leg 3/8” wall 4”x 4” square tubing galvanized ____ ____ ____ Laser cut for product consistency Optional galvanized rear kicker adapters with adjustable azimuth location positioning ____ ____ ____ Available for special high wind applications ____ ____ ____ Available for load dispersion applications such as I beam frame configuration ____ ____ ____ Can be added to package at a later date ____ ____ ____ EASi. fixed/manual AZ/EL turnbuckle kit for fixed system ____ ____ ____ 1 ½” grade B7 threaded rods on both axis ____ ____ ____ Elevation adjustment tube is 2 ½” square with ¼” wall thickness ____ ____ ____ All EASi. antenna attachment/rotation points use SAE 660 bronze flanged bushings ____ ____ ____ EASi. 90 VDC ODU Control System (30 amp, 120 VAC circuit w/disconnect req. ____ ____ ____ 90 VDC Motor drive outputs ____ ____ ____ Dual speed motor control ____ ____ ____ Integrated heater for temperature/dehydration purposes ____ ____ ____ Environmentally sealed NEMA enclosure ____ ____ ____ EASi Other Other Joyce Dayton 10 ton Azimuth ComDRIVE Package ____ ____ ____ 10 ton machine screw ComDRIVE Dynamic 5500 lbs. Static 20,000 lbs. ____ ____ ____ *Note: Typical standard 36 VDC actuators rated at 1500 dynamic/3000 static Special anti-backlash feature ____ ____ ____ Built in digital tachometer for excellent accuracy ____ ____ ____ *Note: 3 times the resolution per inch compared to standard 36 VDC actuators 1 ½ HP Baldor 90 VDC outdoor rated motor ____ ____ ____ Integrated electrical limit switches ____ ____ ____ Integrated brush heaters ____ ____ ____ Integrated hard stop collars ____ ____ ____ Accordion weather boot ____ ____ ____ System allows for periodic lubrication ____ ____ ____ Joyce Dayton 10 ton Elevation ComDRIVE Package ____ ____ ____ 10 ton machine screw ComDRIVE Dynamic 5500 lbs. /Static 20,000 lbs. ____ ____ ____ *Note: Typical standard 36 VDC actuators rated at 1500 dynamic/3000 static Special anti-backlash feature ____ ____ ____ Built in digital tachometer for excellent accuracy *Note: 3 times the resolution per inch compared to standard 36 VDC actuators 1 ½ HP Baldor 90 VDC outdoor rated motor ____ ____ ____ Integrated electrical limit switches ____ ____ ____ Integrated brush heaters ____ ____ ____ Integrated hard stop collars ____ ____ ____ Accordion weather boot ____ ____ ____ System allows for periodic lubrication via grease zerks ____ ____ ____ EASi. lightning kits Class 1and Class 2 ____ ____ ____ Thompson Lightning Products parts including: ____ ____ ____ 12” x 24” solid aluminum point blunt tip w/adapter ____ ____ ____ Aluminum vertical connector point base ____ ____ ____ Aluminum standard cable ____ ____ ____ All products are UL96 rated ____ ____ ____ Class 1 and 2 requirements sized accordingly ____ ____ ____ L Comm Lightning Protectors ____ ____ ____ DC-3 GHz ____ ____ ____ Bi-directional protection ____ ____ ____ Protector will pass DC ____ ____ ____ Easily replaceable gas tube element ____ ____ ____ Multi-Strike Capability ____ ____ ____ RCI 2000 Programmable Antenna Controller with feed drive option ____ ____ ____ Automatic positioning after programming ____ ____ ____ High resolution sensor processing ____ ____ ____ Dual speed ____ ____ ____ Non-volatile memory ____ ____ ____ Built in current limiting ____ ____ ____ Adapti-drive ____ ____ ____ Software limits on all axis ____ ____ ____ Back up by electrical limit switches and antenna stop collars ____ ____ ____ RS-422 PC control interface option ____ ____ ____ RCI 2000 Embedded controller option ____ ____ ____ Controller option for installation of controller at antenna ____ ____ ____ Programmable Antenna Controller with feed drive option ____ ____ ____ Automatic positioning after programming ____ ____ ____ High resolution sensor processing ____ ____ ____ Dual speed ____ ____ ____ Non-volatile memory ____ ____ ____ Built in current limiting ____ ____ ____ Adapti-drive ____ ____ ____ Software limits on all axis ____ ____ ____ RS-422 PC control interface option ____ ____ ____ Outdoor NEMA enclosure ____ ____ ____ RCI Web Server for RCI Controllers ____ ____ ____ Automatic and manual movement operation ____ ____ ____ Displays system faults and allows fault resets ____ ____ ____ Compatible with most web browsers ____ ____ ____ Configurable IP address for easy network configuration ____ ____ ____ Seavey 4 port motorized C/Ku feed assembly ____ ____ ____ Waveguide bends ____ ____ ____ Factory tuned for C and Ku band performance ____ ____ ____ 24 VDC drive motor ____ ____ ____ 5K positioning pot ____ ____ ____ Waveguide bends to allow installation under protective cover ____ ____ ____ Other feeds and multi-feed systems available for this antenna ____ ____ ____ EASi. Feed cover for Seavey feeds ____ ____ ____ White weather/impact resistant cover ____ ____ ____ Custom Seavey feed attachment brackets ____ ____ ____ Custom anti-intrusion inserts to resist pests ____ ____ ____ Quintech LS4 2150/4x16A Quad 4-Way Active Splitter ____ ____ ____ 950-2150 MHz ____ ____ ____ 4x16 signal splitting with zero loss ____ ____ ____ Redundant power supplies ____ ____ ____ 18-24 VDC ____ ____ ____ 1 RU ____ ____ ____ Norsat 3420 PLL C band LNBs ____ ____ ____ +/-2 kHz stability ____ ____ ____ 20K temperature ____ ____ ____ 62 dB gain(Typical) ____ ____ ____ +12 to +24V ____ ____ ____ Norsat HS1027A PLL Ku Band LNBs ____ ____ ____ +/-2 kHz stability ____ ____ ____ 0.7 dB noise figure ____ ____ ____ 60 dB gain(Typical) ____ ____ ____ +15-+24V Microwave Filter Company 13961 WE TI filters ____ ____ ____ Improved insertion loss performance over traditional filters ____ ____ ____ Improved passband edge roll-off over traditional filters ____ ____ ____ Aluminum body to reduce weight/stress on feed system ____ ____ ____ **5G filters available** ____ ____ ____ EASi. CUSTOM control cable (Availability subject to inventory levels) (UL) PLTC DIR BUR or (UL) ITC or (UL) CM C(UL) US 105’C SUN RES DIR BUR “ROHS II” FT-4 Suitable for wet locations ____ ____ ____ Standards 11.1. UL listed as type PLTC per UL standard 13 ____ ____ ____ 11.2. Cable is UL approved for Sunlight Resistant and Direct Burial ____ ____ ____ 11.3. Cable is suitable for Wet Locations ____ ____ ____ 11.4. All materials used in the this cable are RoHS II and REACH compliant ____ ____ ____ 11.5. Maximum Operating Voltage: 300V RMS ____ ____ ____ 11.6. Made in the USA ____ ____ ____ Commscope 5940R Quad RG 11 cable ____ ____ ____ 75 ohm ____ ____ ____ 14 AWG solid center conductor ____ ____ ____ 14 SOL CCS FPE Foil+60% AL BRD+Foil+40% AL Braid FRPVC ____ ____ ____ Foam PE ____ ____ ____ 5.08 (dB/100ft) attenuation at 1450 MHz ____ ____ ____ Safety Standard cETL ETL ____ ____ ____ CMR Non-Plenum ____ ____ ____ RoHS 2011/65/EU ____ ____ ____ ISO 9001 :2015 ____ ____ ____ 100% sweep tested ____ ____ ____ 15 dB structural return loss @ 1000-3000 MHz ____ ____ ____ EASi. Wiring kits Combination of RG 6 Quad feed motor control cable ____ ____ ____ Feed control cable (UL) PLTC DIR BUR or (UL) ITC or (UL) CM C(UL) ____ ____ ____ US 105’C SUN RES DIR BUR “ROHS II” FT-4 Suitable for wet locations ____ ____ ____ Commscope 5781 RG 6 Quad ____ ____ ____ 75 ohm ____ ____ ____ Bare copper center conductor ____ ____ ____ 18 SOL BC FPE Foil+60% AL BRD+Foil+40% AL BRD FRPVC ____ ____ ____ CMG ____ ____ ____ cETL ETL ____ ____ ____ 7.49 (dB/100ft) attenuation at 1450 MHz ____ ____ ____ RoHS 2011/65/EU ____ ____ ____ ISO 9001 :2015 ____ ____ ____ 15 dB structural return loss @ 1000-3000 MHz ____ ____ ____ Installations of EASi systems including controller programming ____ ____ ____ Assembly of the following to specification: Kingpost ____ ____ ____ Actuators or turnbuckle systems ____ ____ ____ Low voltage wiring of all required outdoor systems EASi supplied ____ ____ ____ Feed assembly with filters and LNBs. ____ ____ ____ Complete reflector assembly with integration to kingpost ____ ____ ____ Low voltage wiring of all required indoor systems EASi supplied ____ ____ ____ Termination of all RF ____ ____ ____ Setup of all hard and soft limits ____ ____ ____ Antenna aiming and/or programming of antenna controller ____ ____ ____ EASi. 4.5 De-Ice Options: Clearsat Vinyl snow shield Walton Kynar snow shield/opt. rain/ice quake/electric or gas heat Walton Tedlar snow shield/opt. rain/ice quake/electric or gas heat Walton Sefar snow shield/opt. rain/ice quake/electric or gas heat RTI active rear mounted systems in multiple configurations Walton rear mounted systems in multiple configurations Gas and or electrical systems may require Walton tech to certify.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages5 Page
-
File Size-