Physiological Considerations in Underwater Exercise

Total Page:16

File Type:pdf, Size:1020Kb

Physiological Considerations in Underwater Exercise University of Windsor Scholarship at UWindsor Electronic Theses and Dissertations Theses, Dissertations, and Major Papers 9-1-1986 Physiological considerations in underwater exercise. Robin L. Battley University of Windsor Follow this and additional works at: https://scholar.uwindsor.ca/etd Recommended Citation Battley, Robin L., "Physiological considerations in underwater exercise." (1986). Electronic Theses and Dissertations. 6793. https://scholar.uwindsor.ca/etd/6793 This online database contains the full-text of PhD dissertations and Masters’ theses of University of Windsor students from 1954 forward. These documents are made available for personal study and research purposes only, in accordance with the Canadian Copyright Act and the Creative Commons license—CC BY-NC-ND (Attribution, Non-Commercial, No Derivative Works). Under this license, works must always be attributed to the copyright holder (original author), cannot be used for any commercial purposes, and may not be altered. Any other use would require the permission of the copyright holder. Students may inquire about withdrawing their dissertation and/or thesis from this database. For additional inquiries, please contact the repository administrator via email ([email protected]) or by telephone at 519-253-3000ext. 3208. PHYSIOLOGICAL CONSIDERATIONS IN UNDERWATER EXERCISE BY ROBIN L. BATTLEY A thesis submitted to the Faculty of Graduate Studies in partial fulfillment of the requirements for the degree of Master of Human Kinetics Faculty of Human Kinetics Windsor, Ontario September, 1986 Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. UMI Number: EC54780 INFORMATION TO USERS The quality of this reproduction is dependent upon the quality of the copy submitted. Broken or indistinct print, colored or poor quality illustrations and photographs, print bleed-through, substandard margins, and improper alignment can adversely affect reproduction. In the unlikely event that the author did not send a complete manuscript and there are missing pages, these will be noted. Also, if unauthorized copyright material had to be removed, a note will indicate the deletion. UMI UMI Microform EC54780 Copyright 2010 by ProQuest LLC All rights reserved. This microform edition is protected against unauthorized copying under Title 17, United States Code. ProQuest LLC 789 East Eisenhower Parkway P.O. Box 1346 Ann Arbor, Ml 48106-1346 Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. G Robin Lynn Battley I986 All Rights Reserved 861279 Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. ACKNOWLEDGEMENTS I would like to take this opportunity to extend thanks to those people who assisted me throughout the various stages of this study. In particular I am grateful to the subjects, fellow SCUBA divers, who gave freely of their time and expertise to make this study a reality. I would also like to acknowledge the academic input from Dr. Ray Hermiston, Dr. Paul Taylor and Dr. Kenje Kenno from the University of Windsor, Ontario. All their contributions made this final report possible. Thank you. Robin L. Battley Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. ABSTRACT Five male subjects performed a continuous block lifting task for 15 minute intervals at four different levels - on the surface under laboratory conditions, and submerged in freshwater at 6 feet, 15 feet and 30 feet beneath the surface using standard SCUBA equipment. Heart rate was monitored each minute of every trial and expired gas samples were collected at rest, at 7 minute intervals during the work task and post recovery at each depth. Positive linear relationships were observed between heart rates, V02, VE STPD, 02 pulse and C02 tensions as depth increased (P < 0.05). An inverse relationship was observed between 02 tensions and calculated work efficiency as the working depth increased (P < 0.05). These results are thought to be the combined influences of individual baroreceptic responses and the increased mechanical work of breathing in a hyperbaric environment. The significantly elevated physio­ logical stress experienced at increasing depths by the subjects in this study leads the investigator to suggest that the use of open circuit SCUBA systems for so-called light underwater work be re-examined to ensure the safety of working divers. 11 Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. TABLE OF CONTENTS ABSTRACT ............................................................................................................................ ii LIST OF FIGURES ............................................................................................................ iv LIST OF TABLES .............................................................................................................. v LIST OF APPENDICES..................................................................................................... vi INTRODUCTION ................................................................................................................ 1 Statement of the Problem ................................................................................ 1 Subproblems .............................................................................................................. 2 Definitions ................................................................................................................ 2 Delimitations .............................................................................................................. 6 Assumptions ............................................................ 6 Limitations ................................................................................................................... 6 H ypotheses ................................................................................................................... 7 Significance of the Study ................................................................................ 8 REVIEW OF LITERATURE ........................................................................................... 9 The Diving Environment .................................................................................... 9 Exercising Underwater ....................................................................................... 12 SCUBA Equipment .................................................................................................. 19 C onclusion ................................................................................................................... 20 PROCEDURES....................................................................................................................... 21 Selection of Subjects ........................................................................................... 21 Independent, Intervening and Dependent Variables ..................... 21 Testing Protocol ..................................................................................................... 27 Statistical Analyses .............................................................................................. 29 RESULTS AND DISCUSSION....................................................................................... 31 SUMMARY AND CONCLUSION ...................................................................... 47 APPENDICES.......................................................................................................................... 49 BIBLIOGRAPHY................................................................................................................... 70 iii Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. LIST OF FIGURES Figure 1 Components of a Single Hose Two-Stage Demand Regulator ......................................................................................... ^ 2 The Effect of Depth on Pressures and Volumes ............................................................................................. 3 Oxygen Consumption as a Function of Exertion Level ......................................................................................... 4 Expired Gas Collection S ystem .............................................................. 5 On-Site Data Collection ............................................................................... 6 Heart Rate Versus Depth .......................................................................... 7 V02 and VE STPD Versus D e p th ........................................................ 8 Expired Gas Concentrations Versus Depth .................................. 40 9 02 Pulse Versus Depth ............................................................................. 42 IV Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. LIST OF TABLES Table 1 Oxygen Consumption of Surface and Skin Diving Activities ................................................................... 14 2 Subject Sample ....................................... 33 3 Calculated Work Efficiency .................................................................... 43 4 Subjective Ratings of Work Tasks ...................................................... 45 Reproduced with permission of the copyright owner. Further reproduction prohibited without permission.
Recommended publications
  • Underwater Welding Code
    A-PDF Watermark DEMO: Purchase from www.A-PDF.com to remove the watermark D3.6M:2017 An American National Standard Underwater Welding Code http://www.mohandes-iran.com AWS D3.6M:2017 An American National Standard Approved by the American National Standards Institute January 10, 2017 Underwater Welding Code 6th Edition Supersedes AWS D3.6M:2010 Prepared by the American Welding Society (AWS) D3 Committee on Marine Welding Under the Direction of the AWS Technical Activities Committee Approved by the AWS Board of Directors Abstract This code covers the requirements for welding structures or components under the surface of water. It includes welding in both dry and wet environments. Clauses 1 through 8 constitute the general requirements for underwater welding, while clauses 9 through 11 contain the special requirements applicable to three individual classes of weld as follows: Class A—Comparable to above-water welding Class B—For less critical applications Class O—To meet the requirements of another designated code or specification http://www.mohandes-iran.com AWS D3.6M:2017 International Standard Book Number: 978-0-87171-902-7 © 2017 by American Welding Society All rights reserved Printed in the United States of America Photocopy Rights. No portion of this standard may be reproduced, stored in a retrieval system, or transmitted in any form, including mechanical, photocopying, recording, or otherwise, without the prior written permission of the copyright owner. Authorization to photocopy items for internal, personal, or educational classroom use only or the internal, personal, or educational classroom use only of specific clients is granted by the American Welding Society provided that the appropri- ate fee is paid to the Copyright Clearance Center, 222 Rosewood Drive, Danvers, MA 01923, tel: (978) 750-8400; Internet: <www.copyright.com>.
    [Show full text]
  • Underwater Search for the Lost Radioisotope Device in the Hard-To-Reach Region of the Sea of Okhotsk
    Underwater Search for the Lost Radioisotope Device in the Hard-to-Reach Region of the Sea of Okhotsk Accidental drop of IEU-1 type RTG during its transportation to the lighthouse site of Maria Cape of the Sakhalin island as external load with Mi-8t helicopter belonging to Nickolayevsk flight took place not in the vicinity of the Cape from the height of 100 meters on the 8-th of August 1997 at 5 PM. Radioisotope power generators convert the heat energy generated during fission of the active part of the radionuclide source into electric energy due to the semiconductor thermoelectric converter, store it and supply it to the consumer – navigation equipment. This allows operating the equipment for a long period of time without additional servicing of it. Strontium-90 with the half-life of 28.4 years is the radionuclide source. Activity of radionuclide by the time of the generator decommissioning was 12.95x1014 Bq. The radionuclide itself is located inside the sealed cylindrical container of stainless steel. Gamma radiation presenting potential threat of external radiation does not exceed 200mR/h. Radiation shielding of the device consists of the lead, tungsten-nickel alloy, depleted uranium, and of alloys on its basis. Transportation of RTG is allowed in a special steel transportation container. The sizes are – 1.8x1.3x1.7 m, its weight is 2800 kg. Manufacturing plant guarantees integrity if IEU-1 RTG when it falls from one hundred meters. Search for the sunken RTG was started by the Hydrographic service of the Pacific Fleet, which is in charge of the navigation equipment, in August 1997 and was carried out practically every year.
    [Show full text]
  • Training Objectives for a Diving Medical Physician
    The Diving Medical Advisory Committee Training Objectives for a Diving Medicine Physician This guidance includes all the training objectives agreed by the Diving Medical Advisory Committee, the European Diving Technology Committee and the European Committee for Hyperbaric Medicine in 2011. Rev 1 - 2013 INTRODUCTION The purpose of this document is to define more closely the training objectives in diving physiology and medicine that need to be met by doctors already fully accredited or board-certified in a clinical speciality to national standards. It is based on topic headings that were originally prepared for a working group of European Diving Technology Committee (EDTC) and the European Committee of Hyperbaric Medicine (ECHM) as a guide for diving medicine some 20 years ago by J.Desola (Spain), T.Nome (Norway) & D.H.Elliott (U.K.). The training now required for medical examiners of working divers and for specialist diving medicine physicians was based on a EDTC/ECHM standard 1999 and subsequently has been enhanced by the Diving Medical Advisory Committee (DMAC), revised and agreed in principle by DMAC, EDTC and ECHM in 2010 and then ratified by EDTC and ECHM in 2011. The requirements now relate to an assessment of competence, the need for some training in occupational medicine, the need for maintenance of those skills by individual ‘refresher training’. Formal recognition of all this includes the need to involve a national authority for medical education. These objectives have been applied internationally to doctors who provide medical support to working divers. (Most recreational instructors and dive guides are, by their employment, working divers and so the guidance includes the relevant aspects of recreational diving.
    [Show full text]
  • S0600-Aa-Pro-060 0910-Lp-412-0500 Revision 1
    S0600-AA-PRO-060 0910-LP-412-0500 REVISION 1 UNDERWATER SHIP HUSBANDRY MANUAL CHAPTER 6 SUBMARINE SONAR SYSTEMS This manual supersedes S600-AA-PRO-060 dated 15 April 1991. DISTRIBUTION STATEMENT C: Distribution authorized to U.S. Government agencies and their contractors; administrative/operational use, 1 June 1996. Other requests for this document shall be referred to the Naval Sea Systems Command (SEA 09T). DESTRUCTION NOTICE: Destroy by any method that will prevent disclosure of contents or reconstruction of the document. Published by direction of Commander, Naval Sea Systems Command 1 JUNE 1996 Change 1 dated 15 AUGUST 1999 S0600-AA-PRO-060 LIST OF EFFECTIVE PAGES Date of original pages is: 1 June 1996 Date of Change 1 is: 15 August 1999 Page No. * Change No. Page No. * Change No. Title and A . 1 6-32B blank . 1 Certification Sheet . 1 6-33 through 6-58. 0 blank . 0 6-59 through 6-59A . 1 Flyleaf-1 (Flyleaf-2 blank) . 1 i through iii. 0 6-59B blank . 1 iv blank . 0 6-60 through 6-68. 0 v. 1 6-69 through 6-71. 1 vi through vii . 0 6-72 through 6-103. 0 viii through x . 6-104. 1 blank. 0 6-1 through 6-20 . 0 6-105 through 6-121. 0 6-21 through 6-21A . 1 6-21B blank . 1 6-122 blank. 0 6-22 through 6-28 . 0 A-1 through A-5 . 0 6-29 through 6-32A . 1 A-6 blank . 0 * 0 in this column indicates an original page.
    [Show full text]
  • The Complete Diving System 2 Divator Product Overview
    PRODUCT OVERVIEW DIVATOR THE COMPLETE DIVING SYSTEM 2 DIVATOR PRODUCT OVERVIEW A tragic bus accident in Sweden after the Second World War raised the concern that divers could not be quickly deployed to the crash site. The Swedish government asked Interspiro (“AGA” at that time) if they could provide a rapid deployment diving device for search and rescue operations. Interspiro began an extensive research program and in 1948 the Worlds first underwater breathing apparatus for search and rescue was presented to the Swedish authorities. The device, commonly referred to as the “iron bed” (because of the shape of the carrying frame), featured a breathing valve with inhalation and exhalation in the same diaphragm. The first of many Interspiro innovations in the field of diving. Today, over 60 years later, the latest generation of Interspiro SCUBA – DIVATOR – is still the preferred choice for professional divers around the World. The Interspiro diving philosophy is a system approach. The reason is simple and obvious, to obtain the highest possible safety level for professional divers. © 2015 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are reserved. Interspiro® and DIVATOR® are registered trademarks of Interspiro. This publication may not be copied, photocopied, reproduced, translated, or con- verted to any electronic or machine-readable form in whole or in part without prior written approval from Interspiro. Changes or updates to this publication may be made
    [Show full text]
  • Diving Safe Practices Manual
    Diving Safe Practices Manual Underwater Inspection Program U.S. Department of the Interior February 2021 Mission Statements The Department of the Interior conserves and manages the Nation’s natural resources and cultural heritage for the benefit and enjoyment of the American people, provides scientific and other information about natural resources and natural hazards to address societal challenges and create opportunities for the American people, and honors the Nation’s trust responsibilities or special commitments to American Indians, Alaska Natives, and affiliated island communities to help them prosper. The mission of the Bureau of Reclamation is to manage, develop, and protect water and related resources in an environmentally and economically sound manner in the interest of the American public. Diving Safe Practices Manual Underwater Inspection Program Prepared by R. L. Harris (September 2006) Regional Dive Team Leader and Chair Reclamation Diving Safety Advisory Board Revised by Reclamation Diving Safety Advisory Board (February 2021) Diving Safe Practices Manual Contents Page Contents .................................................................................................................................. iii 1 Introduction .............................................................................................................. 1 1.1 Use of this Manual ............................................................................................. 1 1.2 Diving Safety .....................................................................................................
    [Show full text]
  • International Consensus Standards for Commercial Diving and Underwater Operations
    International Consensus Standards FOR COMMERCIAL DIVING AND UNDERWATER OPERATIONS 6.2 EDITION ASSOCIATION OF DIVING CONTRACTORS INTERNATIONAL International Consensus Standards For Commercial Diving And Underwater Operations INTERNATIONAL CONSENSUS STANDARDS FOR COMMERCIAL DIVING AND UNDERWATER OPERATIONS 6.2 EDITION ASSOCIATION OF DIVING CONTRACTORS INTERNATIONAL, INC. Safety • Education • Communication i International Consensus Standards For Commercial Diving And Underwater Operations No responsibility is assumed by the Association of Diving Contractors International, Inc. (ADCI), its members, board of directors, officers or publisher for any injury and/or damage to persons or property as a matter of liability, negligence or otherwise, or from any use or operation of any methods, product, instruction, standards, rules or ideas contained in the material herein. No suggested test or procedure should be carried out unless, in the reader’s judgment, its risk is justified and the reader assumes all responsibility. All rights reserved. No part of this book may be reproduced, stored in a retrieval system or transmitted in any form or by any means (electronic, mechanical, photocopying, microfilming, recording or otherwise) without written per mission from the Association of Diving Contractors International, Inc. Copyright © Association of Diving Contractors International, Inc. Printed and bound in the United States of America. International Standard Book Number: 0-941332-45-4. Library of Congress control number: 95-077534. Published by: Association of Diving Contractors International, Inc. 5206 FM 1960 West, Suite 202 Houston, TX 77069 www.adc-int.org Third Edition 1991 Fourth Edition 1992 Fifth Edition 2004 Sixth Edition 2011 Sixth Edition 2014 (Revision 6.1) Sixth Edition 2016 (Revision 6.2) ii International Consensus Standards For Commercial Diving And Underwater Operations The Mission of the ADCI is: • To promote the highest possible level of safety in the practice of commercial diving and underwater operations.
    [Show full text]
  • Underwater Acoustic Positioning System
    SCIENTIFIC MANIFEST 2 UNDERWATER ACOUSTIC POSITIONING SYSTEM A.PO.MA.B. merely to collect and publish information of the topic in question. This brief illustration is the ocean underwater positioning system, can be used for educational purposes only and not for operational use. A.PO.MA.B. does not assume any responsibility for the operational use of this treaty. A special thanks to Dr. Patrizio Di Benedetto-Archaeologist, Mr. Digiugno Calcedonio Daniele-Mining Surveyor, Mr. Liggieri Sebastiano Giovanni-Surveyor and Mr. Spadaro Andrea-Surveyor for thorough research and page setting of the text. A.PO.MA.B. – SCIENTIFIC MANIFEST - 2 - Pag. 1 of 33 Intentionally left blank A.PO.MA.B. – SCIENTIFIC MANIFEST - 2 - Pag. 2 of 33 OBJECT: Underwater Acoustic Positioning System An Vessal is a system for the tracking and navigation of underwater vehicles or divers by means of acoustic distance and/or direction measurements, and subsequent position triangulation. Underwater Acoustic Positioning Systems are commonly used in a wide variety of underwater work, including oil and gas exploration, ocean sciences, salvage operations, marine archaeology, law enforcement and military activities. CONTENTS • Underwater Acoustic Positioning System • 1 - Method of Operation • 2 - Underwater Acoustic Positioning System Classes • 3 - History and Examples of Use • Long Baseline (LBL) • 4 - Method of Operation and Performance Characteristics • 5 - History and Examples of Use o 5.1 - Offshore • 6 - USBL • Short Baseline Acoustic Positioning System SBL • 7 - Method of Operation and Performance Characteristics • 8 - History and Examples of Use o 8.1 - Example of SBL System Use: Under-The- Ice Surveying by ROV in Antarctica • GPS Intelligent Buoys • 9 - History and Examples of Use • 10 - Example of Underwater Acoustic-based Weapon Scoring • References A.PO.MA.B.
    [Show full text]
  • Experiment of Nitrox Saturation Diving with Trimix Excursion
    APPLIED HUMAN SCIENCE Journal of Physiological Anthropology Experiment of Nitrox Saturation Diving with Trimix Excursion Shi Zhnog-yuan Chinese Underwater Technology Institute Abstract. Depth limitations to diving operation with with deeper air excursion can increase underwater work air as the breathing gas are well known: air density, efficiency, but the limitation in capabilities when using air oxygen toxicity, nitrogen narcosis and requirement for as the breathing gas during excursions is nitrogen decompression. The main objectives of our experiment narcosis and oxygen toxicity. Recently other approaches were to assess the decompression, counterdiffusion and to self-contained diving in more deeper range have shown performance aspect of helium-nitrogen-oxygen excursions the benefits of using a trimix of helium, nitrogen and from nitrox saturation. The experiment was carried oxygen for effective performance and efficient out in a wet diving stimulator with “igloo” attached to decompression (Mount and Gilliam, 1993; Juvenspan and a 2-lock living chamber. Four subjects of two teams Thomas, 1992; Palmer, 1994). Relevant experience with of 2 divers were saturated at 25 msw simulated depth excursion using helium from nitrox saturation is limited. in a nitrogen oxygen chamber environment for 8 days, In underwater work divers saturated with air at 14 msw during which period they performed 32 divers-excursions excursed to 24 msw breathing 15% oxygen in helium to 60 or 80 msw pressure. Excursion gas mix was trimix (Peterson et al., 1980). The 14 msw depth was calculated of 14.6% oxygen, 50% helium and 35.4% nitrogen, which to be the deepest saturation depth that would allow gave a bottom oxygen partial pressure of 1.0 bars at excursion without creating supersaturation; outcome was 60 msw and 1.3 at 80 msw.
    [Show full text]
  • Volume 5 Number 1, February 1978
    ~\\~~ ~"\\'Q\ ~~ ~~~\~~\~~, OFFICIAL NEWSLETTER OF THE CAVE DIVING SECTION OF THE NATIONAL SPELEOLOGICAL SOCIETY © 1978 by the Cave Diving Section vol.S, no. UNDERWATER SPELEOLOGY COVER published bi-monthly beginning in February The outstanding cover photo to kick off by the fifth year of Underwater SpeZeology The Cave Diving Section of ;s courtesy of New World Publications, The National Speleological Society publ i shers of Diving Guide to Underwa­ ter Florida. The shot is of Pete Velde Membership in the NSS Cave Diving Sec­ near the entrance to Cow Springs Cave, tion is open to any NSS member in good Florida. (Photo is copyrighted by New standing that is interested in cave div­ World Publications.) See story on p. 5. ing and has paid the dues ($3.00 for 1978). Immediate family of members not NEW NCRC DIVING OFFICERS wishing to receive a newsletter may also join for $1.50. Persons not wishing to Tom Cook, national diving officer for join may subscribe for $5.00 per year. the National Cave Rescue Commission, Checks should be made payable to "NSS has announced that two additional mem­ Cave Diving Section" and sent to the bers have agreed to serve as regional treasurer, Stephen Maegerlein. diving officers (see initial list on p. 49 of vol. 4, no. 4 of underwater Spele­ Deadline is the second Friday of the ology). The new additions are Wayne W. preceeding month. Send articles and cor­ Russell, Jr. (Texas) , P.O. Box 492, Aus­ respondence to the editor, Sheck Exley. tin TX 78767; and Chuck Heller(New Jer­ sey and Penn.), 27 Lakeshore Dr., Lake Opinions expressed herein are not nec­ Hiawatha, NJ 07034.
    [Show full text]
  • Underwater Vehicles the History of Working in Water
    Underwater Vehicles The history of working in water Photo courtesy of Robert Keith MAST 55 Why do people go underwater? Under the sea is a dangerous, hostile environment. • Humans can’t breath underwater • Cold • Pressure • Weather The ocean is not always a nice place to work! Photo courtesy of Robert Keith Why do people go underwater? • Profit – If you are willing and able to work in difficult terrain where others cannot work, you can make a bigger profit. • Discovery – Humans have a tendency to be curious and a desire to see and learn new things. • Military Advantage – Go where you enemy cannot see you and you have an advantage. History of working underwater Ancient Greece: Greek Sponge Divers were the first recorded people to work in the underwater environment. At first they didn’t have any special equipment. New Technologies: Diving bell Air inside leather bladders This tech wasn’t much, but it helped them to stay down longer and complete more work. From Nautical Museum of Kalymnos Why did the Greeks go underwater? • Profit: They could acquire a product, sponges, that no one on land could get. • Discovery: Alexander the Great reportedly went underwater with a diving bell to look around. • Military advantage: The Greeks used sponge divers who could hold their breath to cut the anchor lines of enemy ships. Why do you want to go underwater? First recorded female undersea worker. Cyana and her father, Scyillis. 500 BC. The need for technology People found resources (profit) deeper in the oceans. Explorers wanted to explore further into the seas.
    [Show full text]
  • The Complete Diving System
    DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG © 2013 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are reserved. Interspiro® and DIVATOR® are registered trademarks of Interspiro. This publication may not be copied, photocopied, reproduced, translated, or converted to any electronic or machine-readable form in whole or in part without prior written approval from Interspiro. Changes or updates to this publication may be made without prior notice. DIVATOR - The Complete Diving System INTERSPIRO DIVING CONTENT A tragic bus accident in Sweden after the DIVATOR FULL FACE MASK & BREATHING Second World War raised the concern VALVE .........................................................4 that divers could not be quickly deployed DIVATOR Full Face Mask & Breathing Valve 5 to the crash site. The Swedish government DIVATOR Breathing Valve 6 asked Interspiro (“AGA” at that time) if they could provide a rapid deployment DIVATOR HUD (Heads-Up Display) 6 diving device for search and rescue Full Face Mask Accessories 7 operations. DIVATOR REGULATOR .................................8 Interspiro began an extensive research DIVATOR MKII Regulator 9 program and in 1948 the Worlds first underwater breathing apparatus for DIVATOR MKIII Regulator 10 search and rescue was presented to the DIVATOR CYLINDER ..................................12 Swedish authorities. DIVATOR LITE Composite Cylinders 13 The device, commonly referred to as the DIVATOR LITE Cylinder Weights 14 “iron bed” (because of the shape of the carrying frame), featured a breathing DIVATOR Steel Cylinders 15 valve with inhalation and exhalation in DIVATOR CARRYING SYSTEM ...................16 the same diaphragm. The first of many Interspiro innovations in the field of diving.
    [Show full text]