Electrical Test & Measurement Equipment

Total Page:16

File Type:pdf, Size:1020Kb

Electrical Test & Measurement Equipment ELECTRICAL TEST & MEASUREMENT EQUIPMENT www.protecequip.com 844-PROTEC-0 ABOUT US Founded by Kevin Nichols in 2004, Protec Equipment Resources, Inc. has been the leader in electrical test equipment rental for over 10 years. We service our customers with a singular focus To Be the Best at What We Do … By a Wide Margin. Our service has become Legendary within the electrical testing community, and we pride ourselves on continual improvement, centered around our company’s Core Values: • To Be the Best at What We Do … By a Wide Margin We accomplish this by employing a team of professionals with a passion to be the Best and a Commitment to Excellence in everything we do. • Character & Integrity Building trust through ethical and honorable conduct in all our dealings with customers, vendors, and one another. • Teamwork A commitment to each other and an exceptionally high level of interpersonal support. • Legendary Customer Service Our service is Legendary. We care deeply about our customers and their suc- cess, and strive to provide superior customer service, from working after hours to driving 800 miles overnight for an emergency job … we are there when and where you need us. Table of Contents BATTERY TEST EQUIPMENT Battery Ground Fault Testers .........................................................................32 Megger Battery Ground Fault Locator Megger Battery Ground Fault Tracer Battery Hydrometers ........................................................................................33 Alber DMA-35-CRT Hydrometer with Data Logging SBS-2002 Battery Hydrometer SBS-2003 Digital Hydrometer /Density Meter SBS-3500 Hydrometer Battery Impedance Test Sets .........................................................................34 Megger BITE 2P Battery Impedance Test Set Megger BITE 3 Battery Impedance Test Set SBS IBEX-1000P Battery Impedance Test Set Battery Load Unit Test Sets ............................................................................35 Megger Battery Voltage Monitor Megger TORKEL 860 Battery Load Unit Megger TORKEL 950 Battery Load Unit Battery Multimeters ..........................................................................................36 Alber Cellcorder CRT-400 Cell Resistance Tester Current Probes ....................................................................................................37 RxMS 2000A 2” ID Probe RxMS 4000A 4.5x2.5 ID Probe RxMS Wireless Battery Dc Probe RxMS Wireless DCx 10 Channel Probe RxMS Wireless Communications Device RxMS Wireless Temperature and Humidity Probe BATTERY TEST EQUIPMENT Power Quality Monitoring .................................................................................39 RxMS Cx Monitor HIGH POTENTIAL, CABLE & BUS TEST EQUIPMENT AC Hipot Test Equipment ..................................................................................42 Adwel HVA40-10 High Voltage AC Hipot High Voltage ALT-120/60 120kV / 60kV AC Hipot High Voltage PFT-1003CM 100kV 3kVA AC Hipot High Voltage PFT-103CM 10kV 3kVA AC Hipot High Voltage PFT-301CM 30kV 1.5kVA AC Hipot High Voltage PFT-303 30kV 3kVA AC Hipot High Voltage PFT-503CM 50kV 3kVA AC Hipot High Voltage PFT-652CM 65kV 2kVA AC Hipot Hipotronics 100HVT 100kV 5kVA AC Hipot Hipotronics 750-2 50kV AC Hipot Megger 230425 0-4 kV AC and 0-5 kV DC High-Pot Tester Cable Fault Locating Test Equipment ..........................................................45 Amprobe AT-3000 Underground Cable Locator Aquatronics EG 3000 Secondary Cable Fault Locator Aquatronics S.D.A.D. Acoustic Fault Detector Fault Wizard Portable Fault Location System High Voltage CDS-2010B Thumper Fluke FOM Fiber Optic Meter High Voltage CDS-2010B 20kV Thumper Megger PFL22M1500 Power Cable Fault Locator System Megger PFL40A Power Cable Fault Locator System Megger SG32-1500M Power Cable Fault Locator TIF 300HV Tic Tracer UEI CLM100 Cable Length Meter DC Hipots ............................................................................................................... 48 Baker ST112A 12kV Surge Tester Baker ST124R 24kV Surge Tester High Voltage PTS-130 130kV DC Hipot High Voltage PTS-200 200kV DC Hipot with Megohmmeter HIGH POTENTIAL CABLE & BUS TEST EQUIPMENT DC Hipots (cont.) ..................................................................................................49 High Voltage PTS-75 75kV DC Hipot with Megohmmeter High Voltage PTS-80 80kV DC Hipot High Voltage VLF-34E 34kV VLF Hipot High Voltage VLF-65E 65kV VLF Tester Hipotronics 880PL 80kV DC Hipot HV Diagnostics HVA28TD 28kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA30 30kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA34 34kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA60 60kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA90 90kV VLF / DC High Voltage Test Instrument HV Diagnostics TD90-MC 90kV Portable Tan Delta Measurement System Megger 230425 0-4 kV AC and 0-5 kV DC High-Pot Tester SKF (Baker) 12kV Static Motor Analyzer AWA-IV/12 Phasing Kits ........................................................................................................... 53 Bierer PD800W Cordless Phasing Tester HD Electric Double Vision Dual Display Wireless Voltage Indicating Phaser - DDVIP-40 HD Electric Mark II 45kV Phasing Kit HD Electric MARK III 75k 75kV Dual Range Voltmeters and Phasing Set Tan Delta Bridge Test Equipment .................................................................54 High Voltage TD-34E 34kV Tan Delta Bridge High Voltage TDB-60 60kV Tan Delta Bridge HV Diagnostics TD30 30kV Tan Delta Bridge HV Diagnostics TD60 60kV Tan Delta Bridge Time Domain Reflectometers (TDR) ............................................................. 55 High Voltage TDR1669 Time Domain Reflectometer Hipotronics TDR1130A Time Domain Reflectometer Megger CFL510F Hand-held Time Domain Reflectometer Megger CFL535G Advanced Dual Channel TDR Megger MTDR1 Single-Phase Time Domain Reflectometer VLF Hipots .............................................................................................................. 57 High Voltage ADL-1 Data Logger High Voltage VLF-4022CM 40kV AC VLF Hipot High Voltage VLF-6022 60kV VLF Hipot High Voltage VLF-34E 34kV VLF Hipot HIGH POTENTIAL CABLE & BUS TEST EQUIPMENT VLF Hipots (cont.) ................................................................................................58 HV Diagnostics HVA28TD 28kV VLF /DC High Voltage Test Instrument HV Diagnostics HVA30 30kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA34 34kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA60 60kV VLF / DC High Voltage Test Instrument HV Diagnostics HVA90 90kV VLF / DC High Voltage Test Instrument HV Diagnostics TD90-MC 90kV Portable Tan Delta Measurement System INSPECTION TEST EQUIPMENT Borescopes ............................................................................................................62 Everest VIT XLF8575B Borescope Everest VIT XL875 Pro Borescope Olympus IPLEX RT Videoscope Dewpoint Analyzers ..........................................................................................63 Cosa XPDM Portable Dew Point Meter Electrostatic Locators ........................................................................................63 Vaisala DM70 Dewpoint Analyzer ACL 300B Precision Electrostatic Locator Infrared Cameras .................................................................................................64 FLIR C2 Compact Thermal Imaging System FLIR T440 Thermal Imaging Camera FLIR T640 Thermal Imaging Camera Fluke Ti32 Thermal Imager Fluke Ti55 IR FlexCam Thermal Imager Mikron 7200v Infrared Camera with Visual Light Camera Ofil Systems DayCor Superb-OD Corona Camera Extech 42540 Infrared Thermometer Fluke 63 Mini IR Thermometer Fluke 66 Infrared Thermometer Fluke ST60T Non-Contact Infrared Thermometer Wavetek TMA10 Anemometer Thermometer INSPECTION TEST EQUIPMENT Light Meters ..........................................................................................................68 AEMC CA811 Lightmeter AEMC CA813 Lightmeter Fluke FOS-1300 Fiber Optic Light Source Partial Discharge Test Equipment ................................................................ 69 EA Technology UltraTEV Plus+ Partial Discharge Detector EA Technology CableData Collector PMDT PDetector Handheld Partial Discharge Detector Omicron CAL 542 Charge Calibrator Omicron MCT 120 High-Frequency Current Transformer Omicron OMS 605 Portable Partial Discharge (PD) Monitoring System Omicron PD Terminal Box Omicron UCS1 UHF Cable Sensor Omicron UHF 620 Bandwidth Converter Omicron UPG 620 Pulse Generator Tachometers ......................................................................................................... 72 Ametek 1726 Dual Function Digital Tachometer Monarch Nova Strobe Digital Strobe Tachometer Monarch Pocket Laser Tach 200 UHF Radios ............................................................................................................ 73 Motorola XU2100 UHF Radio Ultrasonic Detectors .......................................................................................... 74 Fuji PortaFlow X Ultrasonic Flow Meter UE Systems UltraProbe 100 Ultrasonic Leak Detector UE Systems Ultraprobe 15,000 Touch UE Systems UWC-15 Ultrasonic Wave Form Concentrator (Parabolic Dish) Vibration Meters .................................................................................................. 75 Fluke 810 Vibration Tester Rion VM-82 Vibration Meter SPM Vibrameter VIB-11 Vibration Meter INSULATION & GROUND TEST
Recommended publications
  • The Accuracy Comparison of Oscilloscope and Voltmeter Utilizated in Getting Dielectric Constant Values
    Proceeding The 1st IBSC: Towards The Extended Use Of Basic Science For Enhancing Health, Environment, Energy And Biotechnology 211 ISBN: 978-602-60569-5-5 The Accuracy Comparison of Oscilloscope and Voltmeter Utilizated in Getting Dielectric Constant Values Bowo Eko Cahyono1, Misto1, Rofiatun1 1 Physics Departement of MIPA Faculty, Jember University, Jember – Indonesia, e-mail: [email protected] Abstract— Parallel plate capacitor is widely used as a sensor for many purposes. Researches which have used parallel plate capacitor were investigation of dielectric properties of soil in various temperature [1], characterization if cement’s dielectric [2], and measuring the dielectric constant of material in various thickness [3]. In the investigation the changing of dielectric constant, indirect method can be applied to get the dielectric constant number by measuring the voltage of input and output of the utilized circuit [4]. Oscilloscope is able to measure the voltage value although the common tool for that measurement is voltmeter. This research aims to investigate the accuracy of voltage measurement by using oscilloscope and voltmeter which leads to the accuracy of values of dielectric constant. The experiment is carried out by an electric circuit consisting of ceramic capacitor and sensor of parallel plate capacitor, function generator as a current source, oscilloscope, and voltmeters. Sensor of parallel plate capacitor is filled up with cooking oil in various concentrations, and the output voltage of the circuit is measured by using oscilloscope and also voltmeter as well. The resulted voltage values are then applied to the equation to get dielectric constant values. Finally the plot is made for dielectric constant values along the changing of cooking oil concentration.
    [Show full text]
  • Part 2 - Condenser Testers and Testing Correctly Part1 Condenser Testers and Testing Correctly.Doc Rev
    Part 2 - Condenser Testers and Testing Correctly Part1_Condenser_Testers_And_Testing_Correctly.doc Rev. 2.0 W. Mohat 16/04/2020 By: Bill Mohat / AOMCI Western Reserve Chapter If you have read Part 1 of this Technical Series on Condensers, you will know that the overwhelming majority of your condenser failures are due to breakdown of the insulating plastic film insulating layers inside the condenser. This allows the high voltages created by the “arcing” across your breaker points to jump through holes in the insulating film, causing your ignition system to short out. These failures, unfortunately, only happen at high voltages (often 200 to 500Volts AC)….which means that the majority of “capacitor testers" and "capacitor test techniques" will NOT find this failure mode, which is the MAJORITY of the condenser failure you are likely to encounter. Bottom line is, to test a condenser COMPLETELY, you must test it in three stages: 1) Check with a ohmmeter, or a capacitance meter, to see if the condenser is shorted or not. 2) Assuming your condenser is not shorted, use a capacitance meter to make sure it has the expected VALUE of capacitance that your motor needs. 3) Assuming you pass these first two step2, you then need to test your condenser on piece of test equipment that SPECIFICALLY tests for insulation breakdown under high voltages. (As mentioned earlier, you ohmmeter and capacitance meter only put about one volt across a capacitor when testing it. You need to put perhaps 300 or 400 times that amount of voltage across the condenser, to see if it’s insulation has failed, allowing electricity to “arc across" between the metal plates when under high voltage stress.
    [Show full text]
  • Lab 5 AC Concepts and Measurements II: Capacitors and RC Time-Constant
    Sonoma State University Department of Engineering Science Fall 2017 EE110 Laboratory Introduction to Engineering & Laboratory Experience Lab 5 AC Concepts and Measurements II: Capacitors and RC Time-Constant Capacitors Capacitors are devices that can store electric charge similar to a battery (but with major differences). In its simplest form we can think of a capacitor to consist of two metallic plates separated by air or some other insulating material. The capacitance of a capacitor is referred to by C (in units of Farad, F) and indicates the ratio of electric charge Q accumulated on its plates to the voltage V across it (C = Q/V). The unit of electric charge is Coulomb. Therefore: 1 F = 1 Coulomb/1 Volt). Farad is a huge unit and the capacitance of capacitors is usually described in small fractions of a Farad. The capacitance itself is strictly a function of the geometry of the device and the type of insulating material that fills the gap between its plates. For a parallel plate capacitor, with the plate area of A and plate separation of d, C = (ε A)/d, where ε is the permittivity of the material in the gap. The formula is more complicated for cylindrical and other geometries. However, it is clear that the capacitance is large when the area of the plates are large and they are closely spaced. In order to create a large capacitance, we can increase the surface area of the plates by rolling them into cylindrical layers as shown in the diagram above. Note that if the space between plates is filled with air, then C = (ε0 A)/d, where ε0 is the permittivity of free space.
    [Show full text]
  • Repalrlng Radio Sets
    repalrlng radio sets PART 2 H.W. HELLYER Inthefirst article of this series, Gordon J. King has compressed a wealth of technical information. My brief is to discuss the important mechanical aspects of servicing. Before we can do this, it is necessary to review the tools, instruments and other commonly needed. There are two principal sizes, bench aids that are necessary, and others but tight clhassis screws often need one of the that are desirable though not indispensable. larger types, with a cross-bar, such as used in The emphasis is on tidy and method:cal cycle 'shops. The screwdrivers should preferably service procedure; hence the treatment of have insulated plastic handles. A number of makers the subiect which regards even the kitchen market these especially for electrical work. 'service table workshop as a department'. Beginning at the beginning, we take a * PTIERS look at the basic tools of our trade or hobby. A large pair are essential with square, parallel jaws, a serrated circular section and strong edge cutting blade to deal with iron wire, bolt ends, TOOLS chassis burrs. A pair of long-nosed "electrician's" pliers, with insulated ffiOOLS are personal items. A toolkit is built handle and a smaller. flat- ended pair I up from humble beginnings.with experience for delicate work are also recom- r proving the worth of some tools, modifying the mended. use of others. One or two favourites will be to hand at all times; others are rarely needed. The follow- * CUTTERS list is a suggestion of basic tools most ing often Side and top-cutters of various styles and sizes a't the bench.
    [Show full text]
  • Capacitance and Dissipation Factor Measurementst from 1 Khz to 10 Mhz " Presenter: A
    Capacitance and Dissipation Factor Measurementst from 1 kHz to 10 MHz " Presenter: A. D. Koffman NIST, 220/B162, Gaithersburg, MD 20899 (301) 975-4518 Paper Authors A. D. Koffman, B. C. Waltrip, N. M. Oldham National Institute of Standards and TechnologY: Gaithersburg, MD S. Avramov-Zamurovic U.S. Naval Academy Annapolis, MD Abstract: A measurement technique developed by K. Yokoi et al. at Hewlett-Packard Japan, Ltd. has been duplicated and evaluated at the National Institute of Standards and Technology (NIST) to characterize four-tenninal pair capacitors. The technique is based on an accurate three-terminal measurement made at 1 kHz using a capacitance bridge and wideband single-port measurementsmadebetween30MHzand200 MHz usinga networkanalyzer. The measurement data are fitted to the four-tenninal pair admittance model defmed by R. Cutkosky to compute capacitance and dissipation factor at any frequency up to 10 MHz. Capacitors characterized using this technique will be used as impedance reference standards for a general- purpose digital impedance bridge recently developed at NIST to calibrate inductors and ac resistors. The technique could also lead to a future NIST Special Test for dissipation factor. INTRODUCTION Recent efforts by the Electricity Division at the National Institute of Standards and Technology (NIST) to develop improved impedance comparison methods from 20 Hz to 1 MHz (1)have made it necessary to fmd a means to evaluate the reference impedances used in such comparisons. The impedance-characterization method discussed in this paper is described by Suzuki, et al. (2)and is based on the four-tenninal pair impedance work of Cutkosky (3)and Jones (4,5) The four-terminal pair impedance, Z4tp'of a device is defined as a combination of its real component, R, and its imaginary component, X: Z41p= R+ jX.
    [Show full text]
  • EE 462G Laboratory #1 Measuring Capacitance
    EE 462G Laboratory #1 Measuring Capacitance Drs. A.V. Radun and K.D. Donohue (1/24/07) Revised by Samaneh Esfandiarpour and Dr. David Chen (9/17/2019) Department of Electrical and Computer Engineering University of Kentucky Lexington, KY 40506 I. Instructional Objectives Introduce lab instrumentation with linear circuit elements Introduce lab report format Develop and analyze measurement procedures based on two theoretical models Introduce automated lab measurement and data analysis II. Background A circuit design requires a capacitor. The value of an available capacitor cannot be determined from its markings, so the value must be measured; however a capacitance meter is not available. The only available resources are different valued resistors, a variable frequency signal generator, a digital multi-meter (DMM), and an oscilloscope. Two possible ways of measuring the capacitor’s value are described in the following paragraphs. For this experiment, the student needs to select resistors and frequencies that are convenient and feasible for the required measurements and instrumentation. Be sure to use the digital multi-meter (DMM) to measure and record the actual resistance values used in each measurement procedure. III. Pre-Laboratory Exercise Step Response Model 1. For a series circuit consisting of a voltage source v(t), resistor R, and capacitor C, derive (show all steps) the complete solution for the capacitor voltage vc(t) when the source is a step with amplitude A and the initial capacitor voltage is 0. 2. Assume the source v(t) is a function generator, where the source voltage can only be measured after the 50 Ω internal resistance.
    [Show full text]
  • Capacitance Meter MUDIT AGARWAL
    Capacitance Meter MUDIT AGARWAL Nasiha Ali The principle of operating is counting the pulse oscillator during a fixed time interval produced by another lower frequency oscillator. This oscillator uses the capacitor being measured as the timing element. The capacitance measurement is proportional during pulse counting during a fixed time interval. The astable oscillator formed by IC1c K K K K K K K K K K K K K K K K K K K K K 1 1 1 1 1 1 1 9V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 + + 9V produces a pulse train of constant frequency. Gate 13 12 11 10 9 15 14 3 3 13 12 11 10 9 15 14 13 12 11 10 9 15 14 3 IC4 IC5 IC6 4 4 8 8 4 IC1a also form oscillator whose oscillation period 4511 4511 8 4511 16 5 6 2 1 7 16 16 5 6 2 1 7 6 2 1 7 5 is given approximately by the equation: T=0.7RC. 1C1c Period T is linearly dependent on the capacitance 4093 9 6 5 4 3 2 14131211 10 8 6 5 4 3 16 2 IC2 IC3 10 1 1 C. This period is used as the time interval for one 4518 4518 8 9 7 15 7 15 9 1.5M measurement. The differentiator network following 2K C1 the oscillator creates the negative spikes shaped in 1C1a 9V + 220pf 4093 14 K 1 5 1 9 3 4 R K narrow pulses by IC1b NAND Schmitt trigger.
    [Show full text]
  • LCR Meter PCE-UT 603
    www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 [email protected] http://www.industrial-needs.com/ Manual LCR Meter PCE-UT 603 [email protected] Table of contents Overview .................................................................................................................................................. 3 Safety Information ................................................................................................................................... 3 Rules for Safe Operation .......................................................................................................................... 3 International Electrical Symbols .............................................................................................................. 4 The Meter Structure ................................................................................................................................. 4 Functional Buttons ................................................................................................................................... 5 Display Symbols ...................................................................................................................................... 5 Measurement Operation ........................................................................................................................... 6 A. Measuring
    [Show full text]
  • The RC Circuit
    The RC Circuit The RC Circuit Pre-lab questions 1. What is the meaning of the time constant, RC? 2. Show that RC has units of time. 3. Why isn’t the time constant defined to be the time it takes the capacitor to become fully charged or discharged? 4. Explain conceptually why the time constant is larger for increased resistance. 5. What does an oscilloscope measure? 6. Why can’t we use a multimeter to measure the voltage in the second half of this lab? 7. Draw and label a graph that shows the voltage across a capacitor that is charging and discharging (as in this experiment). 8. Set up a data table for part one. (V, t (0-300s in 20s intervals, 360, and 420s)) Introduction The goal in this lab is to observe the time-varying voltages in several simple circuits involving a capacitor and resistor. In the first part, you will use very simple tools to measure the voltage as a function of time: a multimeter and a stopwatch. Your lab write-up will deal primarily with data taken in this part. In the second part of the lab, you will use an oscilloscope, a much more sophisticated and powerful laboratory instrument, to observe time behavior of an RC circuit on a much faster timescale. Your observations in this part will be mostly qualitative, although you will be asked to make several rough measurements using the oscilloscope. Part 1. Capacitor Discharging Through a Resistor You will measure the voltage across a capacitor as a function of time as the capacitor discharges through a resistor.
    [Show full text]
  • Class Code List Report
    Class Code List Report MAJOR INTERMEDIATE MINOR DESCRIPTION 0001 FOU 3676 0007 007 A FRAME VEHICLE MOUNTING 0007 014 A FRAME VEHICLE MOUNT TRUCK 0010 BAC 0555 0021 002 ABSORBER ALUMINUM 0035 005 ACCELERATOR LINEAR 0035 007 ACCELERATOR READING 0035 015 ACCELERATOR NETWORK PATH 0038 007 ACCELEROMETER 0049 004 ACCESSORY CRYOGENIC 0049 007 ACCESSORY LAN SYSTEM 0049 010 ACCESSORY, STRAIN GAUGE 0058 007 ACQUISITION SYSTEM 0091 003 ADAPTER AC 0091 014 ADAPTER CAMERA 0091 018 ADAPTER COMPUTER 0091 021 ADAPTER ENLARGER 0091 023 ADAPTER ETHERNET 0091 038 ADAPTER LINE SET 0091 042 ADAPTER MEDICAL INSTRUMENT 0091 044 ADAPTER MICROCASSETTE 0091 045 ADAPTER MICROPHONE 0091 049 ADAPTER MICROSCOPE 0091 056 ADAPTER MONITOR 0091 058 ADAPTER PLAYBACK 0091 060 ADAPTER PROJECTOR 0091 062 ADAPTER RADIO 0091 063 ADAPTER RECORDING 0091 070 ADAPTER SLIDE 0091 075 ADAPTER STATIC RAM 0091 090 ADAPTER TELEVISION 0091 095 ADAPTER TERMINAL 0091 100 ADAPTER TRANSPARENCY 0105 007 ADDRESSOGRAPH 0119 007 AERATOR 0126 007 AERIFIER 0140 021 AEROGRAPH 0142 007 AESTHESIOMETER 0144 007 AFTERCOOLER 0146 007 AGGREGOMETER 0147 007 AGITATOR 0150 007 AID ELECTRONIC VOCAL 0150 008 AID HEARING 0150 009 AID THERAPUTICAL 0151 004 AIDE DELTOID 0154 007 AIR CONDITIONER 0154 014 AIR CONDITIONING UNIT 0154 021 AIR HANDLER 0161 007 AIR TRACK 0168 007 AIRBRUSH 0179 007 AIRPAK Printed on 11/5/2010 at 1:23:00PM Page 1 of 139 MAJOR INTERMEDIATE MINOR DESCRIPTION 0182 007 AIRPLANE 0189 003 ALARM AUTO 0189 007 ALARM BURGLAR 0189 014 ALARM FIRE 0189 021 ALARM INTRUDER 0189 022 ALARM SYSTEM ERROR
    [Show full text]
  • Capacitance and Dissipation Factor Characterization at 1 and 10 Mhz
    346 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. VOL. 49. NO.2. APRIL 2000 Uncertainty Analysis for Four Terminal-Pair Capacitance and Dissipation Factor Characterization at 1 and 10 MHz Andrew D. Koffman, Member, IEEE, Svetlana Avramov-Zamurovic, Bryan Cristopher Waltrip, Member, IEEE, and Nile M. Oldham, Fellow, IEEE Abstract-The Electricity Division at the Nationals Institute of Standards and Technology (NIST, formerly NBS) has developed the capability to characterize capacitance and dissipation factor ' ~ H'r H'] for four terminal-pair (4TP) air dielectric capacitors at frequencies from 1kHz to 10 MHz. The method, based on work by Cutkosy and C,h~ Jones of NBS and recent developments by Hewlett-Packard Japan, C1g Chg involves single-port network analyzer impedance measurements at 4 frequencies from 40 MHz to 200 MHz and capacitance measure- TT ments using a precision 1 kHz capacitance meter. A mathematical regression algorithm is used to extrapolate inductance and resis- Fig. 1. Four terminal-pair capacitor: simple model. tance measurements from the network analyzer down to 1 kHz in order to predict capacitance and dissipation factor from 1 kHz to 10 MHz. A comprehensive uncertainty analysis for the procedure TABLE I is presented. TYPE A STANDARD UNCERTAINTIES FOR I-kHz MEASUREMENTS Index Terms-Capacitance, dissipation factor, four terminal pair, impedance, precision measurements, uncertainty analysis. Type A Uncertainty m" 5 I. INTRODUCTION 37 86 HE Electricity Division at the National Institute of Stan- 101 Clhl 4 T dards and Technology (NIST, formerly NBS) has imple- 14 30 mented a system to characterize capacitance and dissipation 1001 Clhl 7 factor for four terminal-pair (4TP) air dielectric capacitors at 30 frequencies from I kHz to 10 MHz [1].
    [Show full text]
  • Measure with Extech
    Measure with Extech MultiMeters | Clamp Meters Thermometers | AirÁow Meters Light Meters | Sound Meters Water Quality Meters | Tachometers Humidity Meters | Moisture Meters Video Borescopes and More! www.extech.com 4 Sound Air Quality As Extech celebrates our 45th anniversary, I can’t help but think about the journey we’ve been on for almost five decades. We take pride in making a difference in your world by providing you with the tools you need to get your job done right. We understand that minimizing down time and providing a safe work environment while controlling costs are challenges you face every day. Electrical Our products have always offered unique functionality at affordable prices and we’ve grown significantly because we learned about your application needs and focused on delivering quality and innovative products for professionals like you. Vibration We work hard to earn your trust by offering top quality tools, a comprehensive product selection and proactive customer support so that you always feel confident on the job with your Extech meter. We ask the question “What do you need to Water Quality measure today?” because we’re all about test and measurement. Whether your measurement requirements are on the shop floor, in the electrical or HVAC department, the safety department, or the test lab, we‘ve got the test equipment you need to get the job done. TURN TO EXTECH FOR THE TOOLS YOU NEED TO KEEP YOUR BUSINESS RUNNING One electrical connection, one motor, one belt, one pressure transmitter. All it takes is one failure to slow down or stop a production line.
    [Show full text]