List of Projects Using Arduino with Advance View
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Lab Essentials Best-Selling Supplies and Equipment
Get What You Need Now! See page 1 for details Lab Essentials Best-selling supplies and equipment Fluid Transfer Lab Equipment Products to help you collect, prepare , and analyze your Consumables & Supplies samples 1-800-363-5900 Find >100,000 products Expert product assistance at ColeParmer.ca Felesha, Application Specialist At Cole-Parmer, you come first. We’ve been in the Cole-Parmer: industry more than 60 years, so we understand your expectations and challenges. That’s why you will only experts in science, find industry-leading brands you can trust, backed by a team of application experts who will work with you to dedicated to your meet your requirements. Consider us part of your team. We are dedicated to being your source for fluid handling success products, instrumentation, equipment, and supplies. Your 100% satisfaction is our number one goal. We look forward to helping you succeed. Have questions? We have answers. Our team of highly-trained technical specialists has more than 150 years of experience solving the most demanding customer applications. We will work with you on product selection, troubleshooting, regulatory compliance, or maintenance and repair. With expertise across scientific and industrial disciplines, we will help you achieve the highest performance and cost effectiveness for your project. Call, email, or live chat today to put us to work for you. 1-800-363-5900 ColeParmer.ca [email protected] Go to ColeParmer.ca/Terms for a full list of terms and conditions. For full information on returns, go to ColeParmer.ca/returns. ©2017 Cole-Parmer Instrument Company, LLC. All rights reserved. -
5410-6001-Rov04 Phase Ia Task B Final Technical Report
7"_ $ YST£ M$ 5410-6001-ROV04 PHASE IA TASK B FINAL TECHNICAL REPORT VOYAGER SPACECRAFT Volume 4 OPERATIONAL SUPPORT EQUIPMENT 17 January 1966 Prepared for Cal|forn|a Institute of Technology Jet Propulsion Laboratory Pasadena, Cal |forn|a Under Contract Number 951113 TRW SYSTEMS GROUP Redondo Beach, California T_WSVSTEM$ CONTENTS Page I. INTRODUCTION II. ELECTRICAL OPERATIONAL SUPPORT EQUIPMENT 4 i. EOSE OBJECTIVES AND DESIGN CRITERIA 4 1.1 Objectives 4 1. Z EOSE Design Criteria 6 Z. EOSE CHARACTERISTICS AND CONSTRAINTS 8 Z. 1 Characteristics 8 2. Z Constraints li 3. SYSTEM LEVEL FUNCTIONAL DESCRIPTIONS i4 3. t System Test Complex 14 3.2 Central Data System Functional Description Z7 3.3 Mission Dependent Equipment 47 3.4 Mission Operations System Test Equipment 56 3.5 Launch Complex Equipment 61 4. SUBSYSTEM LEVEL FUNCTIONAL DESCRIPTIONS 73 4. 1 Power Subsystem EOSE 74 4. Z Computing and Sequencing Subsystem EOSE 78 4.3 Guidance and Control Subsystem EOSE 86 4.4 Radio Subsystem EOSE 91 4.5 Telemetry Subsystem EOSE I0i 4.6 Command Subsystem EOSE ilZ 4.7 Data Storage Subsystem EOSE li9 4.8 Pyrotechnic Subsystem EOSE I Z4 4.9 Propulsion Subsystem EOSE iZ9 4. i0 Science Subsystem EOSE IBZ iii TRWsYSTEMS CONTENTS (Continued) Page III. ASSEMBLY, HANDLING, AND SHIPPING EQUIPMENT 134 i. OBJECTIVES AND CRITERIA 136 I. I Objectives 136 1.2 Criteria 136 Z. CHARACTERISTICS AND RESTRAINTS 138 2. 1 Characteristics 138 Z. 2 Restraints 138 3. SYSTEM LEVEL FUNCTIONAL DESCRIPTIONS 140 IV. OSE IMPLEMENTATION PLAN Z05 1. INTRODUCTION Z05 2. APPROACH 205 3. CRITICAL AREAS Z06 3. -
Temperature Data Logger (Dl2b) User Manual
TEMPERATURE DATA LOGGER (DL2B) USER MANUAL Features Data logger simultaneously displays minimum, maximum and current temperatures The unit will provide a visual and audio alert when temperature rises above or falls below the high and low set points. The min/max feature is designed to monitor and store the highest and lowest readings until the memory is cleared, or removal of battery. The temperature sensor is enclosed in a glycol-filled bottle, protecting it from rapid temperature changes when refrigerator/freezer door is opened. Low battery alert function ( battery symbol flashes) User can select oC or oF temperature display Measuring temperature range -45 ~ 120 oC ( or -49 ~ 248 oF) Operating conditions: -10 ~ 60 oC ( or -50 ~ 140 oF) and 20% to 90% non-condensing (relative humidity) Accuracy : ± 0.5 oC (-10 ~ 10 oC or 14 ~ 50 oF), in other range ± 1 oC ( or ± 2 oF) User defined logging interval 1 6.5 ft (2 meters) NTC probe-connecting cable Rechargeable Li-ion battery to record data up to 8 hours during a power-failure event Powered by a 12VDC power adapter Compatible with a USB 3.0 Extension Cable for durability and easy data transfer Large LED lit LCD screen Dimensions:137mm(L)×76mm(W)×40mm(D) Mounting hole dimension: 71.5mm(W) x 133mm(L) Felix Storch, Inc. │ Bronx, NY 10474│ Tel: (718) 893-3900│ Fax: (844) 478-8799 SAVE THIS MANUAL FOR FUTURE REFERENCE AccuCold, Div of Felix Storch, Inc. | R005-07102018 READ ALL INSTRUCTIONS BEFORE USE Package Contents . Data logger . Instructions manual . 4 GB Memory stick [FAT 32] . -
Alosi, Marlena C., Analysis of Efficiency and User Satisfaction Following The
Alosi, Marlena C., Analysis of Efficiency and User Satisfaction Following the Introduction of Digital Source Documents and Resources in a Clinical Research Setting. Master of Science (Clinical Research Management), November 2015, 111p., 2 tables, 17 figures, reference list of 23 sources. Efficient and accurate data management processes are essential for the successful conduction of clinical trials. The clinical research industry is unique among biomedical fields in that much of the reporting is still conducted using paper-based systems. Recent trends towards exchanging paper-based documentation methods for electronic documentation methods have shown that implementation of digital resources have the potential to expedite clinical development. This practicum sought to evaluate paper-based and electronic documentation processes in a cancer clinic in regards to efficiency and user satisfaction, and determine which documentation form was superior in these areas. Retrospective analyses and a survey were used as the sources of data to assess for these differences. It was determined that the replacement of paper-based methods with electronic methods of documentation at this particular clinic resulted in both greater timeliness and higher user satisfaction. ANALYSIS OF EFFICIENCY AND USER SATISFACTION FOLLOWING THE INTRODUCTION OF DIGITAL SOURCE DOCUMENTS AND RESOURCES IN A CLINICAL RESEARCH SETTING Marlena C. Alosi, B.S. APPROVED BY: _______________________________________________________________________ Lad Dory, Ph.D., FAHA, Major Professor -
Data Logger Sets
Data Logger Sets Complete Data Logger Sets for Process control and Monitoring, for Routine Complete Data Logger Sets for Operation and Control, Mapping and against Acceptable Quality Limit (AQL) Process Qualification Description: Description: • Data Loggers with evaluation software and extensive equipment • Data Loggers for validation with evaluation software and extensive equipment • FDA 21 CFR Part 11 conform software • TÜV certified • FDA 21 CFR Part 11 conform software Applications: Applications: • Process control, Monitoring and routine control in steam sterilizers, washer disinfectors, washer • Operation and Process Qualification in pasteurization and bottle disinfectors for endoscopes as well as bedpan washers. cleaning processes. • Implementation of the electronic Bowie&Dick-Test. • Operation and Process Qualification in steam sterilizers, washer disinfectors, washer disinfectors for endoscopes as well as DAC- • Process and routine control of pasteurization and bottle cleaning processes Universal • Process and routine control in cooking processes • Operation and Process Qualification in cooking processes • Process and routine control in other thermal processes in the food, pharma or medical sector • Operation and Process Qualification in other thermal processes in the food, pharma or medical sector Advantages: Advantages: • Fully automatic and tamper-proof evaluation • Fully automatic and tamper-proof evaluation • Individual evaluation by user-defined evaluations • Individual evaluation by user-defined evaluations • Wide range -
Compact Data Logger with External Probe Socket
GB_024_025.qxd 26.02.03 19:23 Sei e 1 24 Compact data logger with external probe socket With an additional external probe connection, the testo 175-T2 temperature External probes data logger provides a further temperature measurement option. Display/Prints IP68 Battery: 2.5 years The data logger is attached to the wall to ABS casing monitor air temperature, for example, and the separate probe is placed by the goods. -40 to +120°C testo 175-T2 provides information on the 16,000 readings connection between ambient and product temperature. Simultaneous monitoring of product and air Monitors 2 temperatures temperature e.g. in refrigerated rooms, during °C simultaneously production, in containers etc. Fast overview of current reading, last value saved, max/min values, number of times limits exceeded User-friendly operation, convenient analysis testo 175-T2 Internal °C + external °C testo 175-T2, temperature data logger, 2 channels, with internal sensor and external probe socket, wall holder and calibration protocol Collects data on-site, downloads and analyses Part no. 0563 1755 centrally on PC. The high-performance data collector reads out approx. 400 readings/s. See pages 18 to 21 for system overview and data management. Suitable probes at a glance Conn. Description IllustrationMeas. range Accuracy t99 Cable/Length Part no. ±0.2 °C (-20... +40 °C) 35 mm -20... +70 °C 15 s 0628 7510 Stub probe, IP 54 ±0.4 °C (+40.1... +70 °C) Ø 3 mm 40 mm -30... +90 °C ±0.2 °C (0... +70 °C) 60 s Fixed cable 0628 7503* ±0.5 °C (-30.. -
Hanwell Anoxibug ®: Testing a Static Reduced Oxygen Environment System for Treatment at the Bodleian Library
Hanwell Anoxibug ®: Testing a Static Reduced Oxygen Environment System for Treatment at the Bodleian Library Kristie Short-Traxler* ACR, Head of Preventive Conservation, Oxford University Library Services, Bodleian Library, Broad Street, Oxford, OX1 3BG, +44(0)1865287117 [email protected] Alexandra Walker, Preventive Conservator, Oxford University Library Services, Bodleian Library, Broad Street, Oxford, OX1 3BG, +44(0)1865287117 [email protected] *author for correspondence ABSTRACT Some library and archive collections in the Bodleian Library, due to their composition, conservation history or fragility present a problem in terms of available insect infestation treatment methods. In addition to preservation requirements, reduced resources require methods that are easily affordable and sustainable by various library staff with little or no training in laboratory procedures. The use of Anoxibug® a new commercial oxygen absorber from the IMC Group Ltd’s Hanwell range is discussed. The initial trial investigates the effectiveness of the system in killing larval and nymph stages of the insects as well as maintaining suitable environmental control inside the bag. We also discuss the practicality of the set-up and maintenance of the system during the treatment. Finally, the paper will look at how the initial tests are shaping future anoxia control strategies for the Bodleian Libraries. KEYWORDS: library, pest, anoxia, scavenger INTRODUCTION The Bodleian Libraries have been dealing with library and archive pests for over 400 years. During this time, the Libraries have used a relatively small variety of methods for mitigation. To summarise, housekeeping and basic cleaning gave way to various chemicals and fumigation methods until the 1990s when freezing was introduced. -
Mini Data Logger Temperature and Humidity Testo 174H
We measure it. Mini data logger Temperature and humidity testo 174H Long-term stable humidity sensor °C High data security Large display %RH Display of current temperature or humidity values Measurement data store for 16,000 measurement values Fast data analysis and documentation on a PC Illustration 1:1 The mini data logger for temperature and humidity testo The low-cost temperature and humidity data logger 174H is ideal for monitoring temperature- and humidity- guarantees secure measurement results on the basis of sensitive goods in storage. The testo 174H also monitors state-of-the-art measurement technology. The integrated building climate continuously, securely and unobtrusively. sensors ensure long-term stable measurement values. This The free software ComSoft Basic allows fast programming allows you to adhere to and safely document quality of the data logger and easy analysis. assurance guidelines. testo 174H We measure it. Technical data / Accessories Sensor type NTC testo 174H Meas. range -20 to +70 °C Accuracy ±0.5 °C (-20 to +70 °C) testo 174H mini data logger, 2-channel, ±1 digit incl. wall bracket, battery (2 x CR 2032 Resolution 0.1 °C lithium) and calibration protocol Sensor type Testo humid. sensor, cap. Meas. range 0 to 100 %RH* Part no. 0572 6560 Accuracy ±3 %RH (2 to 98 %RH) ±1 digit ±0.03 %RH/K Resolution 0.1 %RH * Not for condensing atmospheres. For continuous use in high humidity (>80 %RH at ≤30 °C for >12 h, >60 %RH at >30 °C for >12 h), please contact us via our website. Set testo 174H General technical data testo 174H mini data logger set, 2-channel, Channels 2 x internal incl. -
Catalog: Ebro Professional Data Logger
Professional Data Logger FOR VALIDATION, ROUTINE CONTROL AND PROCESS MONITORING MEDICINE FOOD PHARMACEUTICAL LABORATORY 2020 New Products SL 2002 Complete Validation Set AL 3305 DAC Adapter Set SL 3302 Complete Validation Set see page 50 see page 52 see page 53 You can find more catalogues on our website: Professionelle Datenlogger Professionelle Messtechnik Professional Measurement Technology (Part No. 1347-0090) (Part No. 1347-0088) (Part No. 1347-0089) If you would like to receive further catalogue copies please send your request via e-mail to [email protected] www.ebro.com Measurements for Life KompetenzCentrum ebro® Theory and practice combined are the key to our successful transfer. Our instructors are all experts in their own fields. The aim is to achieve an in-depth understanding of hardware and software alike. Seminar program 2020 03.03.2020 Basic Training: Software 29.10.2020 25.03. – 26.03.2020 Validation DAC-Universal MK III and 27.10. – 28.10.2020 MK IV 20.04. – 25.04.2020 Validation training VALI B corresponding 21.09. – 26.09.2020 to the framework curriculum of the DGSV Seminar location: Ingolstadt, Germany 05.05.2020 Advanced course measurement 20.10.2020 technology for food control 27.05.2020 Basic Training: practice workshop validation 24.06. – 25.06.2020 System validation in the hospital and in the resident field (Basic course) 13.07. – 15.07.2020 Validation Basic Training for Distributors 14.09. – 16.09.2020 and their costumers Information: Further dates on request. Requirement: 6 participants at least English spoken seminar German spoken seminar You can find the current program on our homepage www.ebro.com/en/training Booking before and February 29th 2020 you can avail of an early bird discount of 20 % Xylem Analytics Germany Sales GmbH & Co. -
Explosive Ordnance Disposal Range RCRA Part B Permit Renewal Application Edwards Air Force Base
AGENCY DRAFT EPA ID NUMBER CA1570024504 Explosive Ordnance Disposal Range RCRA Part B Permit Renewal Application Edwards Air Force Base Prepared for: 412th Civil Engineer Group Environmental Management Division 120 North Rosamond Blvd., Building 3735 Edwards AFB, CA 93524-8600 May 2015 Edwards AFB RCRA Permit Renewal Application EOD Range TABLE OF CONTENTS SECTION PAGE AAA. GENERAL INFORMATION REQUIREMENTS ................................................................ AAA-1 AAA.1 Description of Activities That Require a RCRA Permit ..........................AAA-1 AAA.2 Name, Mailing Address, and Location of Facility, Including a Topographic Map .....................................................................................AAA-2 AAA.3 Standard Industrial Classification Code...................................................AAA-3 AAA.4 Owner/Operator .......................................................................................AAA-3 AAA.5 Indian Lands.............................................................................................AAA-3 AAA.6 Description of Processes Used for Treating Hazardous Waste ...............AAA-3 AAA.7 Specification of Hazardous Wastes Listed or Designated Under CCR Chapter 11 ................................................................................................AAA-4 AAA.8 Listing of All Permits or Construction Approvals ...................................AAA-4 BBB. FACILITY DESCRIPTION ......................................................................................... -
Velostat®) Based Tactile Sensor
polymers Article Polyethylene-Carbon Composite (Velostat®) Based Tactile Sensor Andrius Dzedzickis 1 , Ernestas Sutinys 1, Vytautas Bucinskas 1 , Urte Samukaite-Bubniene 1,2,3, Baltramiejus Jakstys 1, Arunas Ramanavicius 2,3,* and Inga Morkvenaite-Vilkonciene 1,4,* 1 Department of Mechatronics, Robotics, and Digital Manufacturing, Vilnius Gediminas Technical University, J. Basanaviciaus Str. 28, LT-03224 Vilnius, Lithuania; [email protected] (A.D.); [email protected] (E.S.); [email protected] (V.B.); [email protected] (U.S.-B.); [email protected] (B.J.) 2 Department of Physical Chemistry, Faculty of Chemistry, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania 3 Laboratory of Nanotechnology, Center for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania 4 Laboratory of Electrochemical Energy Conversion, Center for Physical Sciences and Technology, Sauletekio av. 3, LT-10257 Vilnius, Lithuania * Correspondence: [email protected] (A.R.); [email protected] (I.M.-V.) Received: 31 October 2020; Accepted: 30 November 2020; Published: 3 December 2020 Abstract: The progress observed in ‘soft robotics’ brought some promising research in flexible tactile, pressure and force sensors, which can be based on polymeric composite materials. Therefore, in this paper, we intend to evaluate the characteristics of a force-sensitive material—polyethylene-carbon composite (Velostat®) by implementing this material into the design of the flexible tactile sensor. We have explored several possibilities to measure the electrical signal and assessed the mechanical and time-dependent properties of this tactile sensor. The response of the sensor was evaluated by performing tests in static, long-term load and cyclic modes. -
Logtag® with 30-Day Summary
2019 1 Dual Probe Vaccine Temperature Data Logger w/ Software-Less Reporting Exceeds CDC & VFC Data Logger Requirements for Vaccine Temperature Monitoring and Compliance FEATURES: • EXCEEDS Current CDC & VFC Requirements for Vaccine Storage And Monitoring • NIST Traceable Certificate • High Accuracy ±0.3°C (±0.6°F) • Log 24 Million Readings on 2G Micro SD Card • Data File in Excel .CSV Format • Retrieve Data from Logger with Removable • SD Memory Card or by USB cable to PC • Logger Records Date, Time, P1 & P2 Temp, and Battery Level in .CSV file • Logging Interval Selectable from 1 to 720 Minutes • Detachable Shatter Proof Vaccine Size Bottle Probes • Bottles Filled with Bio-Safe Glycol Buffer Medium • Large LCD Display shows Current Min Max Temperature for each Sensor plus Time and Low Battery Indication • User Adjustable Low and High Alarm Limits Setting for Each Sensor • Audible and Flashing LED Alarm Indicators • Temperatures in °C or °F Thermco’s new Dual Probe ACCRT8017 Data Logger is the • Time in 12 or 24 Hour Format most powerful logger to date. Designed to • Flip Out Desk Stand meet today’s CDC’s and VFC’s requirements • Battery Life About 10 Months in Continuous Operation with no alarms for vaccine storage and monitoring. Monitor both the refrigerator and freezer temperatures CATALOG NO. DESCRIPTION simultaneously or add the optional ACCRTAMB Dual Probe Vaccine Data Logger to Monitor Refrigerator or Freezer. ambient temperature sensor and log the room Includes... 2yr. NIST Traceable Certificate, 2 Vaccine Bottle Sen- sors, ACCRT8017 temperature, and either a refrigerator or freezer. 2GB Micro SD Card, Micro SD Card Reader, MicroSD to SD card The ACCRT8017 can record 24 million records.