Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices

Total Page:16

File Type:pdf, Size:1020Kb

Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices Therapeutic Products Programme Programme des produits thérapeutiques OUR MISSION: To ensure that the drugs, medical devices, NOTRE MISSION: Faire en sorte que les médicaments, lesmatériels and other therapeutic products available in Canada are safe, médicaux et les autres produits thérapeutiques disponibles au Canada effective and of high quality. soient sûrs, efficaces et de haute qualité. Therapeutic Products Programme Keyword Index To Assist Manufacturers In Verifying The Class of Medical Devices For more information please contact: Don Boyer Licensing Services Division Medical Devices Bureau 1605 Statistics Canada Main Building, Postal Locator: 0301H1 Tunney’s Pasture, Ottawa, Ontario K1A 0L2 phone: (613) 957-7090 fax: (613) 954-7666 e-mail: [email protected] Therapeutic Products Programme Medical Device Keyword Index DRAFT Introduction The Medical Device Keyword Index was prepared to assist manufacturers in verifying the device class for products after application of the Classification Rules for Medical Devices of the Medical Devices Regulations. The Index should also be used in conjunction with the guidance document “Guidance For The Risk Based Classification System, GD006/RevDR-MDB.” Please note that this document is provided as a guide and that in the event of any discrepancy between this guide and the Classification Rules for Medical Devices of the Medical Devices Regulations, the latter shall prevail. What is a Keyword Index? The Medical Device Keyword Index is an alphabetical listing of all the words which appear in all the short descriptors for all the device groups that have been identified by the Medical Devices Bureau. It contains synonyms and industry words that are commonly used to describe the products in these device groups. The listing consists of the following four fields: Keyword, Preferred Name Code or PNC, Risk Class, and Description, in the following order and format: Keyword Pref Name (PNC) Risk Class Description Pump 80FRN 3 Pump, Infusion Definitions Keyword means all the words which appear in the short descriptors for all the generic device groups as well as synonyms and industry words that are commonly used to describe these device groups. PNC or Preferred Name Code is a five digit alpha numeric code (2-numeric and 3-alpha) which represents a device group. The three letters designate the specific device group and the two numbers represent the medical specialty in which it is routinely, but not necessarily exclusively, used. These codes are harmonized with the USFDA as much as is feasible. 73 - Anaesthesiology 80 - General Hospital & Personal Use 90 - Radiology 79 - General & Plastic Surgery 84 - Neurology 74 - Cardiovascular 85 - Obstetrics & Gynaecology 76 - Dental 86 - Ophthalmology 77 - Ear, Nose and Throat 87 - Orthopaedics 78 - Gastroenterology & Urology 89 - Physical Medicine File: KWINDXV2.WPD January 14, 2000 Page 1 of 2 Therapeutic Products Programme Medical Device Keyword Index DRAFT Risk Class is a number from 1 to 4, with 4 representing the highest risk classifiction, determined by the Medical Devices Bureau as representative of the majority of products currently on the database and assigned this device group code (PNC). Description is a string of two or more words that defines a device group. Electronic Formats of the Keyword Index The electronic version of the Keyword Index database contains over 10,000 lines of information and is presented in PDF format. How to use the Keyword Index Instructions: Copy the PDF file to your computer. To search for a device group in the PDF file, go to Tools / Find and enter either the Keyword, PNC or Description you are searching for in the “Find What” field. It must be noted that the device class assigned to a device group is only indicative of what class the majority of this type of device will be. It is not an exact determination. It is the responsibility of each manufacturer to use the Classification Rules for Medical Devices of the Medical Devices Regulations to determine the class of a specific device. e.g. tracheostomy tube (73BTO) The majority of these devices are Class II by rule 2(1). However, if a manufacturer claims the device can be left in place for longer than 30 days, the device class becomes Class III, by rule 2(3). File: KWINDXV2.WPD January 14, 2000 Page 2 of 2 Date: 2000/01/20 Medical Device Keyword Index Page 1 of Pages 144 Keyword Pref Risk Description Name Class 6MM 74DSY 4 PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER 74DYF PROSTHESIS, VASCULAR GRAFT, OF LESS THAN 6MM DIAMETER A-V 78KNR 2 ADAPTER, A-V SHUNT OR FISTULA 78FIQ 3 CANNULA, A-V SHUNT ABBEY 79RHW 1 HOLDER, NEEDLE, OTHER ABDOMINAL 89EXP 1 BELT, ABDOMINAL 80FSD BINDER, ABDOMINAL 78SCC TROCAR, ABDOMINAL 85HEE 3 CHAMBER, DECOMPRESSION, ABDOMINAL ABDUCTION 87AMM 1 IMMOBILIZER, HIP, POST-OP, ABDUCTION 89IOZ SPLINT, ABDUCTION, CONGENITAL HIP DISLOCATION 87WUU SPLINT, ABDUCTION, SHOULDER ABLATION 74AAF 4 SUCTION ABLATION CATHETER SYSTEM (SAC) ABORTION 85KNB 1 INSTRUMENT, DESTRUCTIVE, FETAL, OBSTETRIC 85HHI 2 SYSTEM, ABORTION, VACUUM ABRASIVE 76EJR 1 AGENT, POLISHING, ABRASIVE, ORAL CAVITY 76EHJ DISK, ABRASIVE 76EHL POINT, ABRASIVE ABSORBABLE 79LMG 3 ABSORBABLE HEMOSTATIC AGENTS NON-COLLAGEN BASED 74AAQ ANASTOMOSIS DEVICE FOR MICROVASCULAR SURGERY 85MCN BARRIER, ABSORBABLE, ADHESION 79ACN CLIP, LIGATING ABSORBABLE 87MAI FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE 86HQJ IMPLANT, ABSORBABLE, (SCLERAL BUCKLING METHOD) 87MNU STAPLE, ABSORBABLE 79GAK SUTURE, ABSORBABLE 79GAM SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID 79LMF 4 ABSORBABLE HEMOSTATIC AGENTS, COLLAGEN BASED ABSORBENT 80FOR 1 APPLICATOR, ABSORBENT TIPPED 80FRL MEDICAL, ABSORBENT FIBER 73CBL 2 ABSORBENT, CARBON-DIOXIDE ABSORBER 73BSF 2 ABSORBER, CARBON-DIOXIDE ABSORPTION 79KOZ 1 BEADS, HYDROPHILIC, FOR WOUND EXUDATE ABSORPTION 73BSF 2 ABSORBER, CARBON-DIOXIDE AC 76EFD 1 AMALGAMATOR, DENTAL, AC-POWERED 80FNL BED, AC-POWERED ADJUSTABLE HOSPITAL 86HJO BIOMICROSCOPE, SLIT-LAMP, AC-POWERED 86HKI CAMERA, OPHTHALMIC, AC-POWERED 86HME CHAIR, OPHTHALMIC, AC-POWERED 86HPQ HEADLAMP, OPERATING, AC-POWERED 86HLM INSTRUMENT, MEASURING, LENS, AC-POWERED 86HLQ KERATOSCOPE, AC-POWERED 80FNG LIFT, PATIENT, AC POWERED 79HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 86HLI OPHTHALMOSCOPE, AC-POWERED 86HOO PERIMETER, AC-POWERED 86HLG PUPILLOMETER, AC-POWERED 86HKL RETINOSCOPE, AC-POWERED 86HOK SCREEN TANGENT, PROJECTION AC-POWERED 86HOM SCREEN, TANGENT, AC-POWERED (CAMPIMETER) 86HMF STAND, INSTRUMENT, AC-POWERED, OPHTHALMIC 86HJQ STEREOSCOPE, AC-POWERED 87JEA TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED 79JCX 2 APPARATUS, SUCTION, WARD USE, PORTABLE, AC-POWERED 86HRG ENGINE, TREPHINE, ACCESSORIES, AC-POWERED 76EKX HANDPIECE, DIRECT DRIVE, AC-POWERED 87HWE INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND 86HNO KERATOME, AC-POWERED 86HPO MAGNET, AC-POWERED 86HIX MAXWELL SPOT, AC-POWERED 79GEY MOTOR, SURGICAL INSTRUMENT, AC-POWERED 86HRD STERILIZER, SOFT LENS, THERMAL AC POWERED 73BXM STIMULATOR, NERVE, AC-POWERED 86HKX TONOMETER, AC-POWERED 86HRO UNIT, ELECTROLYSIS, AC-POWERED, OPHTHALMIC 86HQE 3 INSTRUMENT, VITREOUS ASPIRATION AND CUTTING, AC-POWERED AC-POWERED 76EFD 1 AMALGAMATOR, DENTAL, AC-POWERED 80FNL BED, AC-POWERED ADJUSTABLE HOSPITAL 86HJO BIOMICROSCOPE, SLIT-LAMP, AC-POWERED 86HKI CAMERA, OPHTHALMIC, AC-POWERED 86HME CHAIR, OPHTHALMIC, AC-POWERED 86HPQ HEADLAMP, OPERATING, AC-POWERED 86HLM INSTRUMENT, MEASURING, LENS, AC-POWERED Date: 2000/01/20 Medical Device Keyword Index Page 2 of Pages 144 Keyword Pref Risk Description Name Class 86HLQ KERATOSCOPE, AC-POWERED 80FNG LIFT, PATIENT, AC POWERED 79HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 86HLI OPHTHALMOSCOPE, AC-POWERED 86HOO PERIMETER, AC-POWERED 86HLG PUPILLOMETER, AC-POWERED 86HKL RETINOSCOPE, AC-POWERED 86HOK SCREEN TANGENT, PROJECTION AC-POWERED 86HOM SCREEN, TANGENT, AC-POWERED (CAMPIMETER) 86HMF STAND, INSTRUMENT, AC-POWERED, OPHTHALMIC 86HJQ STEREOSCOPE, AC-POWERED 85HDD TABLE, OBSTETRICAL, AC POWERED (AND ACCESSORIES) 87JEA TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED 79JCX 2 APPARATUS, SUCTION, WARD USE, PORTABLE, AC-POWERED 86HRG ENGINE, TREPHINE, ACCESSORIES, AC-POWERED 76EKX HANDPIECE, DIRECT DRIVE, AC-POWERED 87HWE INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND 86HNO KERATOME, AC-POWERED 86HPO MAGNET, AC-POWERED 86HIX MAXWELL SPOT, AC-POWERED 79GEY MOTOR, SURGICAL INSTRUMENT, AC-POWERED 86HRD STERILIZER, SOFT LENS, THERMAL AC POWERED 73BXM STIMULATOR, NERVE, AC-POWERED 86HKX TONOMETER, AC-POWERED 86HRO UNIT, ELECTROLYSIS, AC-POWERED, OPHTHALMIC 86HQE 3 INSTRUMENT, VITREOUS ASPIRATION AND CUTTING, AC-POWERED ACCELERATOR 90IYE 3 ACCELERATOR, LINEAR, MEDICAL ACCESS 78LTH 3 GRAFT, VASCULAR ACCESS 80LMP PORT & CATHETER, SUBCUTANEOUS, INTRASPINAL 74QHK 4 KIT, CATHETERIZATION, CARDIAC ACCESSORIES 78FEB 1 ACCESSORIES, CLEANING, FOR ENDOSCOPE 80WQD ACCESSORIES, LASER 79FWZ ACCESSORIES, OPERATING ROOM, TABLE 78FEM ACCESSORIES, PHOTOGRAPHIC, FOR ENDOSCOPE (EXCLUDE LIGHT 89ILZ ACCESSORIES, TRACTION 87HXF ACCESSORIES, TRACTION (CART, FRAME, CORD, WEIGHT) 89KNO ACCESSORIES, WHEELCHAIR 79FTA LIGHT, SURGICAL, ACCESSORIES 79HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 80KCT PACK, STERILIZATION WRAPPER, BAG AND ACCESSORIES 79GDR SAW, MANUAL AND ACCESSORIES 79KQM SURGICAL CAMERAS AND ACCESSORIES 85HDD TABLE, OBSTETRICAL, AC POWERED (AND ACCESSORIES) 85HHP TABLE, OBSTETRICAL, MANUAL (AND ACCESSORIES) 87JEA TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED 87JEB
Recommended publications
  • B.J.ZH.F.Panther Medical Equipment Co., Ltd. 北京派爾特醫療科技股份
    The Stock Exchange of Hong Kong Limited and the Securities and Futures Commission take no responsibility for the contents of this Application Proof, make no representation as to its accuracy or completeness and expressly disclaim any liability whatsoever for any loss howsoever arising from or in reliance upon the whole or any part of the contents of this Application Proof. Application Proof of B.J.ZH.F.Panther Medical Equipment Co., Ltd. 北京派爾特醫療科技股份有限公司 (the “Company”) (a joint stock company incorporated in the People’s Republic of China with limited liability) WARNING The publication of this Application Proof is required by The Stock Exchange of Hong Kong Limited (the “Stock Exchange”) and the Securities and Futures Commission (the “Commission”) solely for the purpose of providing information to the public in Hong Kong. This Application Proof is in draft form. The information contained in it is incomplete and is subject to change which can be material. By viewing this document, you acknowledge, accept and agree with the Company, its sole sponsor, advisors or members of the underwriting syndicate that: (a) this document is only for the purpose of providing information about the Company to the public in Hong Kong and not for any other purposes. No investment decision should be based on the information contained in this document; (b) the publication of this document or supplemental, revised or replacement pages on the Stock Exchange’s website does not give rise to any obligation of the Company, its sole sponsor, advisors or members of the underwriting syndicate to proceed with an offering in Hong Kong or any other jurisdiction.
    [Show full text]
  • Snakes, Worms and Catheters: Continuum and Serpentine Robots for Minimally Invasive Surgery
    IEEE ICRA 2010 Full Day Workshop Snakes, Worms and Catheters: Continuum and Serpentine Robots for Minimally Invasive Surgery Monday May 3, 2010 Anchorage, Alaska USA Organizers: Pierre E. Dupont Mohsen Mahvash Workshop Contents 1- Introduction 2- Abstract of Invited Talks • Neal Tanner, Hansen Medical (commercialization) 3 • David Camarillo, Hansen Medical (robotic catheters) 5 • Howie Choset, Carnegie Mellon University (snakes) 6 • Pierre Dupont, Children’s Hospital Boston, HMS (continuum robots) 8 • Koji Ikuta, Nagoya University (robotic catheters) 9 • Joseph Madsen, MD, Children’s Hospital, Harvard Med (clinical perspective) 11 • Mohsen Mahvash, Children’s Hospital Boston, HMS (continuum robots) 12 • Rajni Patel, University of Western Ontario (robotic catheters) 14 • Cameron Riviere, Carnegie Mellon University (worm robots) 16 • Nabil Simaan, Columbia University (NOTES) 17 • Russell Taylor, Johns Hopkins University (snake robots) 19 • Robert Webster, Vanderbilt University (continuum robots) 20 • Guang-Zhong Yang, Imperial College (snake robots) 23 3- Short Papers • A Highly Articulated Robotic System (CardioARM) is Safer than a Rigid System for Intrapericardial Intervention in a Porcine Model 24 • Towards a Minimally Invasive Neurosurgical Intracranial Robot 27 • Uncertainty Analysis in Continuum Robot Kinematics 30 • Ultrasound Image-Controlled Robotic Cardiac Catheter System 33 • Steerable Continuum Robot Design for Cochlear Implant Surgery 36 • Modular Needle Steering Driver for MRI-guided Transperineal Prostate Intervention 39
    [Show full text]
  • Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices
    September 12, 2006 NOTICE Our file number: 06-120629-368 Re: Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices Health Canada is pleased to announce the release of the revised Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices. This guidance document supersedes the January 14, 2000 version of the same document. The Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices is intended to assist manufacturers in confirming the classification of medical device products after application of the Classification Rules for Medical Devices set out in Schedule 1 of the Medical Devices Regulations. This guidance document has been revised to reflect changes to the risk- based classification of particular medical device groups. Specifically, the following major changes have been made to the document: • the reclassification of specific medical device groups; • the removal of redundant information; • the addition of medical device groups; and • the omission of product groups that do not fit the meaning of a medical device as defined in the Food and Drugs Act. To search for a medical device group within the Keyword Index to Assist Manufacturers in Verifying the Class of Medical Devices PDF file, go to Edit/Find and enter a keyword, preferred name code or description in the “Find” field. For instance, to verify the risk-based classification of dental burs, enter “bur” or “drill” in the “Find” field. Please note that this guidance document is provided only as a guide and that in the event of any discrepancy between this document and the Classification Rules for Medical Devices described in the Medical Devices Regulations, the latter shall prevail.
    [Show full text]
  • Fine Surgical Instruments for Research™
    FINE SCIENCE TOOLS CATALOG 2021 FINE SCIENCE TOOLS CATALOG FINE SURGICAL INSTRUMENTS FOR RESEARCH™ TABLE OF CONTENTS | CATALOG 2021 Scissors 3 – 35 Spring 3 – 14 Fine 15 – 28 Letter from the Managing Partner Surgical 29 – 35 Bone Instruments 36 – 49 Rongeurs 36 – 38 Dear Customers, Cutters 39 – 47 Other Bone Instruments 47 – 48 After my uncle and founder of Fine Science Tools, Hans, handed Curettes & Chisels 49 over the management of the company to my cousin Rob and I Scalpels & Knives 50 – 61 last year, a lot has happened. Coming to FST as an “outsider”, my primary goal was to learn everything about the products, customers and the entire company. From my very first day, Forceps 63 – 91 I learned just how much my uncle Hans and the excellent Dumont 63 – 73 managerial team, Rob, Michael and Christina were able to Fine 72 – 80 grow the company over the last 45 years from a single office in Moria 74 S&T 75, 77 Vancouver into a global enterprise, a tremendous achievement Standard 81 – 91 that they should be proud of. Through excellent customer Hemostats 92 – 97 service, impeccable product quality and a passionate team, FST has become a household name in surgical and microsurgical instruments and accessories. During the COVID19 pandemic and the following worldwide lockdown, whether at their home office or on-site, our teams Probes & Hooks 99 – 103 around the world were able to provide our customers with the Spatulae 102 – 105 instruments and accessories they needed. Under challenging Hippocampal Tools & Spoons 106 – 107 circumstances, we kept our warehouses open in order to ship Pins & Holders 108 – 109 products to research laboratories, biotech’s and academic Wound Closure 110 – 121 institutions around the world while our support staff actively Needle Holders & Suture 110 – 118 Staplers, Clips & Applicators 119 – 121 continued to provide assistance to all customer questions and Retractors 122 – 129 inquiries.
    [Show full text]
  • Product Catalogue Surgical Metal Instruments
    Single-use Surgical Instruments PRODUCT CATALOGUE Table of Content AcXess Single Use Instruments and Application Sets Surgical Scissors 2 Dissecting Scissors 3 More Scissors 4 Forceps 6 Artery Forceps 7 Anatomic Artery Forceps 7 Surgical Tissue Forceps 9 Forceps 11 Anatomic Dissecting Forceps 11 Surgical Tissue Forceps 12 Needle holder 14 Retractors 15 Curettes 16 AcXess OR Sets 17 ProKit Application Sets 18 ProKit Suture Removal Sets 18 ProKit Care Sets for Wound Treatment 19 AcXess Stitch Alternatives 20 Surgical Stapler 20 Surgical Staple Remover 20 Product Overview AcXess SUORG Disposable Instruments for high demands o Complex, precise finishing o Special steel alloy o Funktionality and safety suitable for long interventions without loss of quality Instruments in SUORG quality are marked in light blue 1 AcXess Surgical Scissors Single-use surgical instruments Item no.: Characteristic Length SU* MI.22.111.130 sharp/sharp, straight 130 mm 20 pcs. MI.22.111.140 sharp/sharp, straight 140 mm 20 pcs. *: individual sterile packaging Item no.: Characteristic Length SU* MI.23.111.130 sharp/blunt, straight 130 mm 20 pcs. MI.23.111.140 sharp/blunt, straight 140 mm 20 pcs. *: individual sterile packaging Item no.: Characteristic Length SU* MI.24.111.130 blunt/blunt, straight 130 mm 20 pcs. MI.24.111.140 blunt/blunt, straight 140 mm 20 pcs. *: individual sterile packaging Item no.: Characteristic Length SU* MI.22.112.115 sharp/sharp, curved 115 mm 20 pcs. MI.22.112.130 sharp/sharp, curved 130 mm 20 pcs. MI.22.112.140 sharp/sharp, curved 140 mm 20 pcs.
    [Show full text]
  • Biodegradable Surgical Staple Composed of Magnesium Alloy
    www.nature.com/scientificreports OPEN Biodegradable Surgical Staple Composed of Magnesium Alloy Hizuru Amano 1, Kotaro Hanada2, Akinari Hinoki3, Takahisa Tainaka3, Chiyoe Shirota3, Wataru Sumida3, Kazuki Yokota3, Naruhiko Murase3, Kazuo Oshima3, Kosuke Chiba3, 3 3 Received: 11 February 2019 Yujiro Tanaka & Hiroo Uchida Accepted: 25 September 2019 Currently, surgical staples are composed of non–biodegradable titanium (Ti) that can cause allergic Published: xx xx xxxx reactions and interfere with imaging. This paper proposes a novel biodegradable magnesium (Mg) alloy staple and discusses analyses conducted to evaluate its safety and feasibility. Specifcally, fnite element analysis revealed that the proposed staple has a suitable stress distribution while stapling and maintaining closure. Further, an immersion test using artifcial intestinal juice produced satisfactory biodegradable behavior, mechanical durability, and biocompatibility in vitro. Hydrogen resulting from rapid corrosion of Mg was observed in small quantities only in the frst week of immersion, and most staples maintained their shapes until at least the fourth week. Further, the tensile force was maintained for more than a week and was reduced to approximately one-half by the fourth week. In addition, the Mg concentration of the intestinal artifcial juice was at a low cytotoxic level. In porcine intestinal anastomoses, the Mg alloy staples caused neither technical failure nor such complications as anastomotic leakage, hematoma, or adhesion. No necrosis or serious infammation reaction was histopathologically recognized. Thus, the proposed Mg alloy staple ofers a promising alternative to Ti alloy staples. Intestinal anastomosis using staples is widely practiced in surgery nowadays1–4. Staples used for this procedure are primarily composed of non–biodegradable titanium (Ti) alloy.
    [Show full text]
  • Medical and Surgical Management, and Implications for the Practicing Gastroenterologist
    UCSF UC San Francisco Previously Published Works Title Morbid obesity-the new pandemic: medical and surgical management, and implications for the practicing gastroenterologist. Permalink https://escholarship.org/uc/item/8pw8k8v6 Journal Clinical and translational gastroenterology, 4(6) ISSN 2155-384X Authors Cello, John P Rogers, Stanley J Publication Date 2013-06-06 DOI 10.1038/ctg.2013.6 Peer reviewed eScholarship.org Powered by the California Digital Library University of California Citation: Clinical and Translational Gastroenterology (2013) 4, e35; doi:10.1038/ctg.2013.6 & 2013 the American College of Gastroenterology All rights reserved 2155-384X/13 www.nature.com/ctg CLINICAL/NARRATIVE REVIEW Morbid Obesity—The New Pandemic: Medical and Surgical Management, and Implications for the Practicing Gastroenterologist John P. Cello, MD1 and Stanley J. Rogers, MD1 The gastroenterologist, whether in academic or clinical practice, must face the reality that an increasingly large percentage of adult patients are morbidly obese. Morbid obesity is associated with significant morbidity and mortality including enhanced morbidity from cardiovascular, cerebrovascular, hepatobiliary and colonic diseases. Most of these associated diseases are actually preventable. Based on the 1991 NIH consensus conference criteria, for most patients with a body mass index (BMI ¼ weight in kilograms divided by the height in meters squared) of 40 or more, or for patients with a BMI of 35 or more and significant health complications, surgery may be the only reliable option. Currently in the United States, over 250,000 bariatric surgical procedures are being performed annually. The practicing gastroenterologist in every community, large and small, must be familiar with the various surgical procedures together with their associated anatomic changes.
    [Show full text]
  • (12) STANDARD PATENT No. AU 2010200618 B2 (19
    (12) STANDARD PATENT (11) Application No. AU 2010200618 B2 (19) AAUSTRALIAN PATENT OFFICE (54) Title Circular Stapler Buttress Combination (51) International Patent Classification(s) A61B 17/00 (2006.01) A61B 17/072 (2006.01) A61B 17/115 (2006.01) A61B 17/11 (2006.01) (21) Application No: 2010200618 (22) Date of Filing: 2010.02.19 (43) Publication Date: 2010.03.11 (43) Publication Journal Date: 2010.03.11 (44) Accepted Journal Date: 2012.06.21 (62) Divisional of: 2003220427 (71) Applicant(s) Synovis Life Technologies, Inc. (72) Inventor(s) Mooradian, Daniel L.;Oray, Nicholas B.;Kluester, William F. (74) Agent / Attorney Wrays, Ground Floor 56 Ord Street, West Perth, WA, 6005 (56) Related Art US 6099551 US 5503638 39 2010 ABSTRACT A combination medical device comprising a circular stapler instrument and Feb one or more portions of preformed buttress material adapted to be stably positioned 19 upon the staple cartridge and/or anvil components of the stapler prior or at the time of 5 use. Positioned buttress material(s) are delivered to a tissue site where the circular stapler is actuated to connect previously severed tissue portions. An embodiment of the invention allows tissue portions to be joined without the use of sutures. The buttress material is made up of two regions, one of which serves primarily to secure the buttress material to the stapler prior to actuation, and one of which serves 2010200618 10 primarily to form the improved seal. The former region is severed and discarded upon activation of the circular stapler to form anastomoses, while the remaining material secures and seals the newly connected tissue.
    [Show full text]
  • Fine Surgical Instruments for Research™ Hsin-Yi Road, Sec
    INTERNATIONAL Scissors, Bone Instruments Fine Science Tools Inc. & Scalpels 202-277 Mountain Highway pages 3–61 North Vancouver, British Columbia Canada V7J 3T6 Telephone 800-665-5355 / 604-980-2481 Fax 800-665-4544 / 604-987-3299 E-Mail [email protected] Web finescience.ca Fine Science Tools (USA) Inc. 373-G Vintage Park Drive F Forceps & Hemostats Foster City, California 94404-1139 I pages 63–97 Telephone 800-521-2109 / 650-349-1636 N Fax 800-523-2109 / 650-349-3729 E E-Mail [email protected] Web finescience.com S C I E Fine Science Tools GmbH N Vangerowstraße 14 C 69115 Heidelberg Germany E Telephone +49 (0) 62 21 - 90 50 50 Fax +49 (0) 62 21 - 90 50 590 T Probes, Needle Holders, O E-Mail [email protected] Thread, Retractors & Clamps Web finescience.de O pages 99–133 L S InterFocus Ltd. Pentagon Business Park Cambridge Road Linton, Cambridge CB21 4NN C United Kingdom A Telephone +44 (0)1223 894833 T Fax +44 (0)1223 894235 A Surgical & Laboratory E-Mail [email protected] L Accessories Web surgicaltools.co.uk O pages 135–161 G 2 Muromachi Kikai Co., Ltd. 0 4-2-12, Nihonbashi-Muromachi 1 Chuo-ku 4 Tokyo 103-0022 Japan Telephone (03) 3241-2444 Fax (03) 3241-2940 E-Mail [email protected] Student Quality Instruments Web muromachi.com pages 163–167 Proserv Instruments Co., Ltd. 7F-2, No. 413 Fine Surgical Instruments for Research™ Hsin-Yi Road, Sec. 4 Taipei, Taiwan R.O.C. Telephone (02) 27230455 Fax (02) 27230799 2014 E-Mail [email protected] Web proserv.com.tw TABLE OF CONTENTS | CATALOG 2014 Scissors 3 – 37 Spring 3 – 14 WE PROUDLY STOCK Fine 15 – 30 Surgical 31 – 37 Bone Instruments 38 – 51 DUMONT® Rongeurs 38 – 41 A selection of over 50 of the most popular Cutters 42 – 49 Other Bone Instruments 50 Dumont forceps are offered in this catalog.
    [Show full text]
  • WOUND CLOSURE Round Handled Needle Holder Round Handled Needle Holder with Suture Cutter Castroviejo
    WOUND CLOSURE Castroviejo Round Handled Needle Round Handled Micro pattern, with Holder with Suture Cutter Needle Holder slightly blunted tips. Round handles allow easy Round handles allow easy fingertip adjustments. fingertip adjustments. Cautionary note: Never use a micro needle holder with needles that are too thick, as this can easily damage the NEEDLE HOLDERS fine jaws. Use only micro needles of less than 0.2 mm diameter (see page 116). Straight Curved 9 cm 9 cm Curved Straight With lock With lock Cutting edge: 3.5 mm 12.5 cm No. 12060-01 No. 12061-01 14 cm With lock Without lock No. 12075-12 Without lock Without lock No. 12075-14 No. 12060-02 No. 12061-02 Without lock No. 12076-12 110 USA +1 800-521-2109 / +1 650-349-1636 · CANADA +1 800-665-5355 / +1 604-980-2481 · GERMANY +49 (0) 62 21-90 50 50 WOUND CLOSURE Mathieu Castroviejo with Tungsten Carbide Jaws Extra slim and narrow profile, with squeeze-lock. Facilitates excellent wrist motion for suturing. For more information see page 183. NEEDLE HOLDERS With tungsten With tungsten carbide jaws carbide jaws 14 cm 14 cm 14 cm For more information see page 183. With lock With lock With lock No. 12565-14 No. 12010-14 No. 12510-14 FINESCIENCE.COM · MOST ITEMS SHOWN ACTUAL SIZE 111 PRODUCTS ARE FOR RESEARCH AND VETERINARY PURPOSES ONLY. WOUND CLOSURE Halsey Halsey with Tungsten Carbide Jaws For more information see page 183. NEEDLE HOLDERS With tungsten With tungsten Smooth carbide jaws carbide jaws 13 cm 13 cm For more information 12.5 cm see page 183.
    [Show full text]
  • Surgery and Healing in the Developing World
    Surgery and Healing in the Developing World Glenn W. Geelhoed, M.D., FACS Professor of Surgery Professor of International Medical Education Professor of Microbiology and Tropical Medicine George Washington University Medical Center Washington, D.C., U.S.A. L A N D E S B I O S C I E N C E GEORGETOWN, TEXAS U.S.A. Surgery and Healing in the Developing World LANDES BIOSCIENCE Georgetown, Texas U.S.A. 2005 Landes Bioscience Printed in the U.S.A. Please address all inquiries to the Publisher: Landes Bioscience, 810 S. Church Street, Georgetown, Texas, U.S.A. 78626 Phone: 512/ 863 7762; FAX: 512/ 863 0081 While the authors, editors, sponsor and publisher believe that drug selection and dosage and the specifications and usage of equipment and devices, as set forth in this book, are in accord with current recommendations and practice at the time of publication, they make no warranty, expressed or implied, with respect to material described in this book. In view of the ongoing research, equipment development, changes in governmental regulations and the rapid accumulation of information relating to the biomedical sciences, the reader is urged to carefully review and evaluate the information provided herein. Contents Foreword .......................................................................... ix Preface.............................................................................. xi 1. Preparation Time .............................................................. 1 Harvey Bratt 2. Surgery in Developing Countries ...................................... 6 John E. Woods 3. A Commitment to Voluntary Health Care Service .......... 13 Donald C. Mullen 4. International Surgical Education: The Perspective from Several Continents ........................ 18 Glenn W. Geelhoed 5. Medicine Writ Large in the Raw, without Power or Plumbing ............................................ 25 Glenn W.
    [Show full text]
  • Multicenter Prospective Evaluation of a New Articulating 5-Mm Endoscopic Linear Stapler
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Springer - Publisher Connector Surg Endosc (2016) 30:1883–1893 and Other Interventional Techniques DOI 10.1007/s00464-015-4406-4 Multicenter prospective evaluation of a new articulating 5-mm endoscopic linear stapler 1 2 3 4 Andreas Kuthe • Alexander Haemmerle • Kaja Ludwig • Stephan Falck • 6 1 5 7 Wolfgang Hiller • Frederick Mainik • Stephan Freys • Lev Dubovoy • 7 4 Joachim Jaehne • Karl Oldhafer Received: 24 February 2015 / Accepted: 2 July 2015 / Published online: 25 July 2015 Ó The Author(s) 2015. This article is published with open access at Springerlink.com Abstract Results Seven centers enrolled 160 subjects, 150 of Background The objective of this study was to evaluate which were followed up to at least 30 days postoperatively. the safety and efficacy of a novel 5-mm laparoscopic linear Intraoperative success: In 423 deployments, there were two stapler in clinical gastrointestinal surgical applications. staple line leaks and five staple line bleeds, all of which Methods A prospective, single-arm study with an open were intraoperatively resolved. In addition, incomplete enrollment of subjects requiring stapling of the gastroin- staple lines were noted as a result of user error (n = 15) or testinal (GI) tract was performed. The study endpoints were device-related issues (n = 22), all of which were imme- the number of complications and technical failures asso- diately resolved and none of which resulted in a compli- ciated with the use of a novel stapler when compared to cation or a change of the surgical procedure.
    [Show full text]