Storageworks RAID Array 200 Online Mgt Utility for Openvms AXP User's
Total Page:16
File Type:pdf, Size:1020Kb
StorageWorks RAID Array 200 Online Management Utility for OpenVMS AXP User's Guide AA–Q6WVB–TE Digital Equipment Corporation Maynard, Massachusetts Second Printing, April 1995 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that might appear in this document. The software, if any, described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software or equipment that is not supplied by Digital Equipment Corporation or its affiliated companies. Copyright 1995 by Digital Equipment Corporation. All rights reserved. Printed in the U.S.A. The following are trademarks of Digital Equipment Corporation: AXP, OpenVMS, StorageWorks, SWXCR, and the Digital logo. The following are third-party trademarks: Microsoft and MS-DOS are registered trademarks and Windows is a trademark of Microsoft Corporation. Intel, Intel486, and i486 are trademarks of Intel Corporation. All other trademarks and registered trademarks are the property of their respective holders. Contents Revision Record...................................................................................................................ix About This Guide ...............................................................................................................xi 1 Installing the RAID Array 200 Online Management Utility for OpenVMS 1.1 Introduction.............................................................................................................1-1 1.2 Before Installing the Utility.....................................................................................1-2 1.3 Contents of Kit ........................................................................................................1-3 1.4 Loading the Utility ..................................................................................................1-6 1.4.1 Systems Running OpenVMS V6.1.....................................................................1-6 1.4.1.1 Boot Device Installation -- OpenVMS V6.1.......................................................1-7 1.4.1.1.1 Identify Devices for OpenVMS V6.1..............................................................1-7 1.4.1.1.2 Installing OpenVMS V6.1 ..............................................................................1-8 1.4.1.1.3 Invoking the PSCI Load Procedure .................................................................1-8 1.4.1.2 Data Device Installation -- OpenVMS V6.1.......................................................1-9 1.4.1.3 Extended Command Line Utilities --OpenVMS V6.1.......................................1-10 1.4.2 Systems Running OpenVMS V6.2...................................................................1-10 1.4.2.1 Boot Device Installation -- OpenVMS V6.2.....................................................1-10 1.4.2.1.1 Initializing a Boot Device for Shadowing .....................................................1-10 1.4.2.1.2 Installing OpenVMS V6.2 ............................................................................1-11 1.4.2.1.3 Invoking the PCSI Load Procedure ...............................................................1-12 1.4.2.2 Data Device Installation -- OpenVMS V6.2.....................................................1-13 1.4.2.2.1 Initializing a Data Device for Shadowing......................................................1-13 1.4.2.2.2 Invoking the PCSI Load Procedure ...............................................................1-13 1.4.2.3 Extended Command Line and GUI -- OpenVMS V6.2.....................................1-14 1.5 Shadowing a Logical RAID Drive .........................................................................1-15 1.5.1 Preparing a Logical RAID Drive as System Drive for Shadowing -- OpenVMS V6.2 .........................................................................1-16 1.5.2 Preparing a Logical RAID Drive as Data Drive for Shadowing -- OpenVMS V6.2 .........................................................................1-17 AA–Q6WVB–TE iii StorageWorks RAID Array 200 Online Management Utility for OpenVMS AXP 2 Using the RAID Array 200 Online Management Utility for OpenVMS Command Line 2.1 Introduction.............................................................................................................2-1 2.2 Monitoring the RAID Subsystem.............................................................................2-2 2.2.1 Invoking a Monitor Process...............................................................................2-2 2.2.2 Qualifiers for the MONITOR Command............................................................2-3 2.2.3 Events Reported by the Monitor ........................................................................2-7 2.2.4 Adding the MONITOR Command to your System Startup File..........................2-8 2.2.5 Stopping a Monitor process ...............................................................................2-9 2.3 Performing Parity Check and Repair on the RAID Subsystem ...............................2-10 2.3.1 Invoking the Parity Check Utility ...................................................................2-10 2.3.2 Qualifiers for the CHECK Command...............................................................2-11 2.4 Working With Drives ............................................................................................2-14 2.4.1 Understanding Parameters ...............................................................................2-14 2.4.2 Making a Hot Spare Drive ...............................................................................2-15 2.4.3 Failing a Drive.................................................................................................2-16 2.4.4 Rebuilding a Drive ..........................................................................................2-17 2.4.5 Making a Drive Optimal..................................................................................2-18 2.5 Viewing Help ........................................................................................................2-18 3 Command Line Messages 3.1 Introduction.............................................................................................................3-1 3.2 Messages from the Monitor Process ........................................................................3-1 3.3 Messages from the Parity Check Utility.................................................................3-10 3.4 Messages from the Working with Drive Commands ..............................................3-11 4 Using the RAID Array 200 Online Management Utility for OpenVMS Graphical User Interface 4.1 Overview of the RAID Array 200 Online Management Utility for OpenVMS Graphical User Interface (GUI)................................................................................4-1 4.2 Accessing the Online Management Utility for OpenVMS GUI ................................4-2 4.3 Using the Online Management GUI.........................................................................4-4 4.3.1 Using the Mouse................................................................................................4-4 4.3.2 Using Windows .................................................................................................4-5 4.3.3 Using Menus .....................................................................................................4-6 4.3.4 Using Help ........................................................................................................4-6 4.3.5 Exiting form the Online Management GUI ........................................................4-6 4.4 Viewing the Subsystem from the Online Management GUI .....................................4-7 iv AA–Q6WVB–TE Contents 4 Using the RAID Array 200 Online Management Utility for OpenVMS Graphical User Interface (cont) 4.4.1 Selecting a Subsystem .......................................................................................4-7 4.4.2 Viewing Disk Drives .......................................................................................4-10 4.4.3 Viewing Logical RAID Drives.........................................................................4-14 4.5 Printing the Configuration .....................................................................................4-17 5 Maintaining the Subsystem with the GUI 5.1 Maintaining the Subsystem......................................................................................5-1 5.2 Replacing a Failed Drive .........................................................................................5-2 5.2.1 Hot Spare ..........................................................................................................5-3 5.2.2 Hot Swap...........................................................................................................5-3 5.2.3 Marking a Drive as Failed .................................................................................5-4 5.2.3.1 Rebuilding a Drive ............................................................................................5-6 5.2.3.2 Marking a Drive as Optimal ..............................................................................5-8 5.3 Making a Hot Spare.................................................................................................5-9