Phoroptor® Vrx

Total Page:16

File Type:pdf, Size:1020Kb

Phoroptor® Vrx ® Phoroptor VRX Digital Refraction System User’s Guide ©2017 AMETEK, Inc. Reichert, Reichert Technologies, Phoroptor, and ClearChart are registered trademarks of Reichert, Inc. AMETEK is a registered trademark of AMETEK, Inc. Bluetooth is a registered trademark of Bluetooth SIG. All other trademarks are property of their respective owners. The information contained in this document was accurate at time of publication. Specifications subject to change without notice. Reichert, Inc. reserves the right to make changes in the product described in this manual without notice and without incorporating those changes in any products already sold. ISO 9001/13485 Certified – Reichert products are designed and manufactured under quality processes meeting ISO 9001/13485 requirements. Refer to IEC 60601-1 for system level information. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Reichert, Inc. Caution: Federal law restricts this device to sale by or on the order of a licensed practitioner. Rx only. Table of Contents Contents Warnings and Cautions .......................................................................................................................6 Symbol Information..............................................................................................................................8 Introduction ..........................................................................................................................................9 Indications for Use .........................................................................................................................9 Contra-Indications .........................................................................................................................9 Unpacking Instructions ......................................................................................................................10 Parts Identification ............................................................................................................................12 Setup .................................................................................................................................................14 Connecting the Phoroptor VRx System Components .................................................................14 Leveling the Phoroptor Head .......................................................................................................16 Face Shields ................................................................................................................................17 Near Vision Rod and Card ...........................................................................................................18 Turn the Unit On and Off .............................................................................................................18 Connect External Devices to the Phoroptor VRx...............................................................................19 Connect External Devices with Reichert Wireless Serial Adapters ...................................................20 Connect Acuity Systems to the Phoroptor VRx .................................................................................24 Connecting Multiple Phoroptor VRx Units .........................................................................................25 User Guide Standards .......................................................................................................................27 Controller Keypad ..............................................................................................................................28 Icon Description .................................................................................................................................29 Active Data Field .........................................................................................................................29 Auxiliary Lenses or Filters ...........................................................................................................30 Controller Button Descriptions and Effects ..................................................................................31 Options/Setup Menu ..........................................................................................................................32 Screens Available through the Options/Set-Up Menu .................................................................32 Settings ........................................................................................................................................33 Language .....................................................................................................................................33 Refraction Sequence ...................................................................................................................33 Aperture Default ..........................................................................................................................33 Cylinder +/- .................................................................................................................................34 Axis 0/180 ....................................................................................................................................34 Prism Units ..................................................................................................................................34 Retinoscopy .................................................................................................................................34 Fog Amount .................................................................................................................................34 BB Fog Amount ...........................................................................................................................34 VA Up Arrow.................................................................................................................................34 NRA/PRA Order ...........................................................................................................................34 Near Chart Units ..........................................................................................................................34 CC ...............................................................................................................................................35 XCyl Auto .....................................................................................................................................35 XCyl Mode ...................................................................................................................................35 XCyl Equal Keypad Button ..........................................................................................................35 Date Format .................................................................................................................................36 Time format ..................................................................................................................................36 Keypad LED ................................................................................................................................36 Sleep ...........................................................................................................................................36 Output Options ............................................................................................................................36 16241-101 Rev. D 3 Table of Contents (continued) Programs ...........................................................................................................................................39 Creating a Program .....................................................................................................................39 Selecting Charts for Program Steps ............................................................................................40 Modifying a Step in the Program .................................................................................................41 Deleting a Step from your Program .............................................................................................41 Copying a Program already created ............................................................................................41 Exporting a Program ....................................................................................................................41 Importing a Program from an outside source (USB drive) ...........................................................42 Clearing a Program .....................................................................................................................42 Running a Program .....................................................................................................................43 Charts ................................................................................................................................................44 Selecting a Chart .........................................................................................................................44 Chart for Optotypes .....................................................................................................................45
Recommended publications
  • Accuracy of Noncycloplegic Retinoscopy, Retinomax Autorefractor, and Suresight Vision Screener for Detecting Significant Refractive Errors
    Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology Accuracy of Noncycloplegic Retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for Detecting Significant Refractive Errors Marjean Taylor Kulp,1 Gui-shuang Ying,2 Jiayan Huang,2 Maureen Maguire,2 Graham Quinn,3 Elise B. Ciner,4 Lynn A. Cyert,5 Deborah A. Orel-Bixler,6 and Bruce D. Moore7 1The Ohio State University College of Optometry, Columbus, Ohio 2University of Pennsylvania, Philadelphia, Pennsylvania 3Children’s Hospital of Pennsylvania, Philadelphia, Pennsylvania 4Pennsylvania College of Optometry at Salus University, Elkins Park, Pennsylvania 5Northeastern State University, Oklahoma College of Optometry, Tahlequah, Oklahoma 6University of California Berkeley School of Optometry, Berkeley, California 7New England College of Optometry, Boston, Massachusettes Correspondence: Marjean Taylor PURPOSE. To evaluate, by receiver operating characteristic (ROC) analysis, the ability of Kulp, The OSU College of Optome- noncycloplegic retinoscopy (NCR), Retinomax Autorefractor (Retinomax), and SureSight try, 338 West Tenth Avenue, Colum- Vision Screener (SureSight) to detect significant refractive errors (RE) among preschoolers. bus, OH 43210; [email protected]. METHODS. Refraction results of eye care professionals using NCR, Retinomax, and SureSight (n 2588) and of nurse and lay screeners using Retinomax and SureSight ( 1452) were Submitted: October 13, 2013 ¼ n ¼ Accepted: January 21, 2014 compared with masked cycloplegic retinoscopy results. Significant RE was defined as hyperopia greater than þ3.25 diopters (D), myopia greater than 2.00 D, astigmatism greater Citation: Kulp MT, Ying G-S, Huang J, than 1.50 D, and anisometropia greater than 1.00 D interocular difference in hyperopia, et al. Accuracy of noncycloplegic greater than 3.00 D interocular difference in myopia, or greater than 1.50 D interocular retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for difference in astigmatism.
    [Show full text]
  • Retinoscopy/Autorefraction, Which Is the Best Starting Point for A
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Universidade do Minho: RepositoriUM Title: Retinoscopy/Autorefraction, which is the best starting point for a non-cycloplegic refraction? Running Title: Retinoscopy vs. Autorefraction Authors: J Jorge 1, MSc, Member of faculty A Queirós 1, Member of faculty JB Almeida 1, MSc, PhD, Member of faculty MA Parafita 2, MSc, MD, PhD, Member of faculty Institutions: 1 Department of Physics (Optometry), School of Sciences. University of Minho. Braga. Portugal. 2 Department of Surgery (Ophthalmology), School of Optics and Optometry. University of Santiago de Compostela. Spain Corresponding Author: Jorge Jorge Address: Departamento de Física, Universidade do Minho Campus de Gualtar 4710 – 057 Braga Portugal Tel: +351 253 604 333 Fax: +351 253 604 061 E-mail: [email protected] The authors state that they have no proprietary or commercial interest in Autorefractor Nidek ARK 700A. Key words: Refraction, refractive error, accuracy, automated refractor, retinoscopy, subjective refraction, orthogonal functions, and astigmatism. Acknowledgment: Authors thank contributions of José Manuel González-Méijome. ABSTRACT Purpose: The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A) and retinoscopy with subjective refraction. Methods: Measurements of autorefraction obtained with the ARK700A and retinoscopy were performed on 192 right eyes from 192 healthy young adults and compared with subjective refraction. These measurements
    [Show full text]
  • The Use of Automated Refractors in the Military
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by CommonKnowledge Pacific University CommonKnowledge College of Optometry Theses, Dissertations and Capstone Projects 5-1984 The use of automated refractors in the military James E. Eberle Pacific University Recommended Citation Eberle, James E., "The use of automated refractors in the military" (1984). College of Optometry. 1292. https://commons.pacificu.edu/opt/1292 This Dissertation is brought to you for free and open access by the Theses, Dissertations and Capstone Projects at CommonKnowledge. It has been accepted for inclusion in College of Optometry by an authorized administrator of CommonKnowledge. For more information, please contact [email protected]. The use of automated refractors in the military Abstract The use of automated refractors in the military Degree Type Dissertation Degree Name Master of Science in Vision Science Committee Chair John R. Roggenkamp Subject Categories Optometry This dissertation is available at CommonKnowledge: https://commons.pacificu.edu/opt/1292 Copyright and terms of use If you have downloaded this document directly from the web or from CommonKnowledge, see the “Rights” section on the previous page for the terms of use. If you have received this document through an interlibrary loan/document delivery service, the following terms of use apply: Copyright in this work is held by the author(s). You may download or print any portion of this document for personal use only, or for any use that is allowed by fair use (Title 17, §107 U.S.C.). Except for personal or fair use, you or your borrowing library may not reproduce, remix, republish, post, transmit, or distribute this document, or any portion thereof, without the permission of the copyright owner.
    [Show full text]
  • Quality of Eyeglass Prescriptions from a Low-Cost Wavefront Autorefractor Evaluated in Rural India: Results Of
    bioRxiv preprint doi: https://doi.org/10.1101/390625; this version posted August 13, 2018. The copyright holder for this preprint (which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. 1 TITLE 2 Quality of eyeglass prescriptions from a low-cost wavefront autorefractor evaluated in rural India: results of 3 a 708-participant field study 4 AUTHORS 5 Nicholas J. Durr,1, 2,* Shivang R. Dave,2,* Daryl Lim,2 Sanil Joseph,3 Thulasiraj D Ravilla,3 Eduardo Lage2,4 6 * these authors contributed equally to this work 7 1 Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA 8 2 PlenOptika Inc., Allston, MA, USA 9 3 Aravind Eye Care System, Madurai, Tamil Nadu, India 10 4 Department of Electronics and Communications Technology, Universidad Autónoma de Madrid, Spain 11 Correspondence to: 12 Nicholas J. Durr 13 Biomedical Engineering Department 14 Clark Hall 208E 15 3400 N Charles St 16 Baltimore MD 21218 17 USA 18 email: [email protected] bioRxiv preprint doi: https://doi.org/10.1101/390625; this version posted August 13, 2018. The copyright holder for this preprint (which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. 19 SYNOPSIS 20 Eyeglass prescriptions can be accurately measured by a minimally-trained technician using a low-cost 21 wavefront autorefractor in rural India. Objective refraction may be a feasible approach to increasing 22 eyeglass accessibility in low-resource settings. 23 ABSTACT 24 Aim 25 To assess the quality of eyeglass prescriptions provided by an affordable wavefront autorefractor 26 operated by a minimally-trained technician in a low-resource setting.
    [Show full text]
  • The Effect of Age on Dark Focus Distance and Visual Information Transfer Rate
    The Effect of Age on Dark Focus Distance and Visual Information Transfer Rate Nantakrit Yodpijit Dissertation submitted to the faculty of the Virginia Polytechnic Institute and State University in partial fulfillment of the requirements for the degree of Doctor of Philosophy In Industrial and Systems Engineering Thurmon E. Lockhart, Chair Brian M. Kleiner, Member Karen A. Roberto, Member Woodrow W. Winchester III, Member October 14, 2010 Blacksburg, VA Keywords: Age, Autorefractor, Dark Focus, Visual Information Transfer Rate Copyright 2010, Nantakrit Yodpijit The Effect of Age on Dark Focus Distance and Visual Information Transfer Rate Nantakrit Yodpijit ABSTRACT Although the static measure of accommodation is well documented, the dynamic aspect of the resting state (dark focus) of accommodation is still unknown. Previous studies suggest that refractive error is minimal at the intermediate resting point of accommodation – i.e., at the dark focus distances. Additionally, aging is closely linked to increased refractive error. In order to assess the effects of age on dark focus distance and its utility in enhancing the visual information transfer rate, two experiments were conducted under nighttime condition (scotopic vision) in a laboratory setting. A total of forty participants with normal vision or corrected to normal vision were recruited from four different age groups (younger: 26.9±5.0 years; middle-aged: 50.7±4.8 years; young-old: 64.6±2.8 years; and old-old: 79.8±6.1 years). Each age group included ten participants. In Experiment I, the accommodative status of dark focus at the fovea was assessed objectively using the modified autorefractor, a newly developed method to continuously monitor the accommodation process.
    [Show full text]
  • Comparisons of Wavefront Refraction, Autorefraction, and Subjective Manifest Refraction
    Tzu Chi Medical Journal 25 (2013) 43e46 Contents lists available at SciVerse ScienceDirect Tzu Chi Medical Journal journal homepage: www.tzuchimedjnl.com Original Article Comparisons of wavefront refraction, autorefraction, and subjective manifest refraction Hong-Zin Lin a,b, Chien-Chung Chen c, Yuan-Chieh Lee a,b,c,d,* a Department of Ophthalmology, Buddhist Tzu Chi General Hospital, Hualien, Taiwan b Graduate Institute of Medical Sciences, Tzu Chi University, Hualien, Taiwan c Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan d Department of Medicine, Tzu Chi University, Hualien, Taiwan article info abstract Article history: Objectives: To compare cycloplegic wavefront refraction, autorefraction, and subjective manifest Received 5 November 2012 refraction. Received in revised form Materials and Methods: Thirty-one myopic eyes in 17 patients were studied. Subjective manifest refraction 10 December 2012 was measured and deemed as the true refraction status. After inducing cycloplegia by administering 1% Accepted 27 December 2012 tropicamide, cycloplegic autorefraction was measured using a Topcon autorefractor, and wavefront refrac- tion was measured with an Allegretto wave analyzer. Refraction data were presented as the spherical Keywords: equivalent and astigmatism. Astigmatismwas converted tovector powerand analyzed by the Alpins method. Autorefraction Subjective manifest refraction Results: Both cycloplegic wavefront refraction and autorefraction showed good correlations with sub- 2 Wavefront refraction jective refraction. The adjusted R value was 0.9726 between cycloplegic autorefraction and subjective manifest refraction, and 0.9693 between cycloplegic wavefront refraction and subjective manifest refraction. Compared with subjective manifest refraction, a myopic shift of À0.14 Æ 0.06 D was noted in cycloplegic wavefront refraction (p ¼ 0.0182).
    [Show full text]
  • The Biometric Parameters of Aniso-Astigmatism and Its Risk Factor in Chinese Preschool Children: the Nanjing Eye Study
    The biometric parameters of aniso-astigmatism and its risk factor in Chinese preschool children: the Nanjing Eye Study Haohai Tong The rst Aliated Hospital with Nanjing medical University Qingfeng Hao The First Aliated Hospital with Nanjing Medical University Zijin Wang The First Aliated Hospital with Nanjing Medical University Yue Wang The First Aliated Hospital with Nanjing Medical University Rui Li The First Aliated Hospital with Nanjing Medical University Xiaoyan Zhao The First Aliated Hospital with Nanjing Medical University Qigang Sun Maternal and Child Healthcare Hospital of Yuhuatai District Xiaohan Zhang Wuxi Children's Hospital Xuejuan Chen The First Aliated Hospital with Nanjing Medical University Hui Zhu The First Aliated Hospital University with Nanjing Medical University Dan Huang The First Aliated Hospital with Nanjing Medical University Hu Liu ( [email protected] ) Jiangsu Province Hospital and Nanjing Medical University First Aliated Hospital Research article Keywords: aniso-astigmatism, Apgar score, preschool children, population-based study Posted Date: December 30th, 2020 DOI: https://doi.org/10.21203/rs.3.rs-33135/v3 License: This work is licensed under a Creative Commons Attribution 4.0 International License. Read Full License Version of Record: A version of this preprint was published on February 3rd, 2021. See the published version at https://doi.org/10.1186/s12886-021-01808-7. Page 1/10 Abstract Backgrounds: Aniso-astigmatism may hinder normal visual development in preschool children. Knowing its prevalence, biometric parameters and risk factors is fundamental to children eye care. The purpose of this study was to determine the biometric components of aniso-astigmatism and associated maternal risk factors in Chinese preschool children.
    [Show full text]
  • Vision Procedures Manual
    National Health and Nutrition Examination Survey VISION PROCEDURES MANUAL (Revised January 2001) TABLE OF CONTENTS Chapter Page 1 INTRODUCTION ........................................................................................... 1-1 1.1 Overview of Vision Exam Component............................................... 1-1 1.2 General Overview of Procedures ........................................................ 1-1 2 EQUIPMENT .................................................................................................. 2-1 2.1 Description of Exam Room in the MEC............................................. 2-1 2.2 Description of Equipment and Supplies ............................................. 2-1 2.2.1 The Lensmeter..................................................................... 2-2 2.2.2 The Autorefractor/Keratometer........................................... 2-2 2.3 Equipment Set Up Procedures ............................................................ 2-2 2.3.1 Start of Stand Procedures .................................................... 2-2 2.3.2 Daily Procedures ................................................................. 2-5 2.3.3 Tolerance............................................................................. 2-5 2.4 Recording in ISIS................................................................................ 2-6 2.4.1 Start of Stand Quality Control............................................. 2-6 2.4.2 Daily Quality Control.......................................................... 2-7 2.4.3 End
    [Show full text]
  • Review of Basic Ophthalmic Pretesting GOALS
    10/10/2019 Review of Basic Ophthalmic Pretesting Constance Crossnoe, OD GOALS Provide a refresher on the workup for a basic comprehensive eye exam and a few specialized exams To help standardize documentation of ophthalmic data collected by technicians Help technician to be more efficient Doctor’s Expectations of Technicians Get the patient ready for the doctor as quickly, yet as accurately, as possible Clean exam room equipment with alcohol in front of the patient ♦ Occluders ♦ Phoropter (!!) ♦ Slit lamp chin rest and forehead bar Notify doctor of abnormal findings from the workup 1 10/10/2019 Doctor’s Expectations of Technicians Be available when the doctor exits the exam room To receive instructions such as: o Instill dilating drops o Perform extra testing o Pull contact lenses and/or teach CL insertion and removal o Escort the patient to the optical or checkout desk Assist with the clinic flow by knowing the status of each patient (or at least the patients you worked up) o the patient spends the minimum amount of time possible in the clinic o the doctor does not have any down time Every doctor is >DIFFERENT< Check-in process Pretesting EFFICIENCY While the doctor is with the patient When doctor comes out of the exam room 2 10/10/2019 EFFICIENCY Check-in Process Things that MUST be done by front desk before patient can be taken by technician: o Insurance card and ID copied/scanned o Consents signed o Demographics confirmed o Copay collected (depends on office policy) When you are available to work up a patient, check the waiting room/front desk line for patients that are filling out paperwork.
    [Show full text]
  • Autorefractor/Keratometer HRK-8000A Huvitz
    User’s Manual Auto Ref/Keratometer HRK-8000A --------------------------------------------------------------- Auto Ref/Keratometer HRK-8000A 1 IMPORTANT NOTICE ! WARNING Potential electromagnetic or other interference between medical equipments and other devices being operated together in the same environmental may expert an adverse influence on functioning of the medical equipment. Non-medical equipments not in compliance with the requirements of EN 60601-1 and EN 60601-1-2 should not be used together in the same environmental as the medical equipments. This equipment has been tested and found to comply with the limits for medical devices in IEC 60601-1-2:2001. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. Power Cord For use of equipment in rated voltage less than 125Vac,minimum 6A,Type SJT or SVT , 18/3AWG,10A, max 3.0m long : One end with Hospital Grade Type, NEMA 5-15P Other end with appliance coupler. For use of equipment in rated voltage less than 250Vac,minimum 6A,Type SJT or SVT , 18/3AWG,10A, max 3.0m long : One end terminatesd with blade attachment plug(HAR) Type, NEMA 6-15P. This product may malfunction due to electromagnetic waves caused by portable personal telephones, transceivers, radio-controlled toys, etc. Be sure to avoid having objects such as, which affect this product, brought near the product. The information in this publication has been carefully checked and is believed 2 Auto Ref/Keratometer HRK-8000A --------------------------------------------------------------- to be entirely accurate at the time of publication. HUVITZ assumes no responsibility, however, for possible errors or omissions, or for any consequences resulting from the use of the information contained herein.
    [Show full text]
  • Quality of Eyeglass Prescriptions from a Low-Cost Wavefront Autorefractor Evaluated in Rural India: Results of a 708-Participant Field Study
    BMJ Open Ophth: first published as 10.1136/bmjophth-2018-000225 on 14 June 2019. Downloaded from Original article Quality of eyeglass prescriptions from a low-cost wavefront autorefractor evaluated in rural India: results of a 708-participant field study Nicholas J Durr, 1 Shivang R Dave,2 Daryl Lim,2 Sanil Joseph,3 Thulasiraj D Ravilla, 3 Eduardo Lage2,4 To cite: Durr NJ, Dave SR, ABSTRACT Lim D, et al. Quality of eyeglass Objective To assess the quality of eyeglass prescriptions Key messages prescriptions from a low- provided by an affordable wavefront autorefractor operated cost wavefront autorefractor by a minimally trained technician in a low-resource setting. What is already known about this subject? evaluated in rural India: results Methods and Analysis 708 participants were recruited ► A lack of eye care providers in low-resource settings of a 708-participant field study. from consecutive patients registered for routine eye contributes to a large burden of uncorrected refrac- BMJ Open Ophthalmology tive errors. 2019;4:e000225. doi:10.1136/ examinations at Aravind Eye Hospital in Madurai, India, ► Autorefractors are conventionally considered too bmjophth-2018-000225 or an affiliated rural satellite vision centre. Visual acuity (VA) and patient preference were compared between trial expensive and inaccurate to significantly to improve lenses set to two eyeglass prescriptions from (1) a novel refractive eye care capacity in these settings. NJD and SRD contributed wavefront autorefractor and (2) subjective refraction by an equally. What are the new findings? experienced refractionist. ► Eyeglass prescriptions can be accurately measured Results The mean±SD VA was 0.30±0.37, –0.02±0.14 Received 8 October 2018 by a minimally trained technician using a low-cost Revised 10 May 2019 and −0.04±0.11 logarithm of the minimum angle of wavefront autorefractor in rural India.
    [Show full text]
  • Subjective Refraction and Prescribing Glasses
    Subjective Refraction and Prescribing Glasses The Number One (or Number Two) Guide to Practical Techniques and Principles Richard J. Kolker, MD Subjective Refraction and Prescribing Glasses: Guide to Practical Techniques and Principles November 2014 The author states that he has no financial or other relationship with the manufacturer of any commercial product or provider of any commercial service discussed in the material he contributed to this publication or with the manufacturer or provider of any competing product or service. Initial Reviews "Wow, a fantastic resource! Giants like you and David Guyton who can make refraction understandable and enjoyable are key. This book will make it so much easier for our residents." —Tara A. Uhler, MD Director, Resident Education Wills Eye Hospital "Subjective Refraction and Prescribing Glasses: Guide to Practical Techniques and Principles is really awesome." —Jean R. Hausheer, MD, FACS Clinical Professor Dean McGee Eye Institute Many thanks for volunteering your time and expertise for the benefit of resident education. —Richard Zorab Vice President of Clinical Education American Academy of Ophthalmology Copyright © 2015 Richard J. Kolker, MD All rights reserved. 2 Subjective Refraction and Prescribing Glasses: Guide to Practical Techniques and Principles Contents About the Author, Acknowledgments 4 Foreword by David L. Guyton, MD 5 Preface 6 Introduction 7 1. Practical Optics • Goal of Refraction, Six Principles of Refraction, Snellen Visual Acuity 8 • Spherical Refractive Errors 9 • Astigmatism
    [Show full text]