Architectural , Wall and Perimeter/Roof Edge Systems 800-PAC-CLAD | PAC-CLAD.COM 1 TABLE OF CONTENTS PAC-CLAD® PRODUCT RANGE 3-7 PAC-CLAD PRODUCT RANGE AND APPLICATIONS Petersen Aluminum Corporation (PAC) was founded in 1965 PAC-CLAD PANELS 8-9 PAC-CLAD COLOR CHART AND AVAILABILITY as a service center to the architectural metal industry. Petersen is an industry leader in providing factory-produced 10-11 SNAP-CLAD PANELS Petersen provides products of the highest possible quality metal panels, maintaining extensive roll-forming equipment in within reliable, dependable lead times. Petersen’s strong all regional plants. Each Petersen facility produces panels that national sales base allows for large inventories and cost have been leveled. Standing seam, exposed fastener, flush wall, Snap-Clad economies for its customers. soffit and horizontal wall panels are factory-formed in lengths 12-13 TITE-LOC PANELS Headquartered in Elk Grove Village, Illinois, located just outside up to 64’. Refer to the specific product pages, or consult the of Chicago, Petersen also operates full production facilities in local factory for maximum lengths and capabilities for each Tite-Loc Tite-Loc Plus Annapolis Junction, Maryland; Tyler, Texas; Phoenix, Arizona facility. Matching flashing and trim also may be factory-formed, or field-formed from PAC-CLAD material. 14-15 SNAP-ON PANELS and Acworth, Georgia, plus a regional sales office in Andover, Minnesota. In addition to the information found in this catalog, PAC-CLAD ACCESSORIES PAC maintains an extensive website at pac-clad.com where a Snap-On Snap-On High Petersen fabricates a wide range of roofing accessories SS Batten Snap-On SS PDF of this catalog is available in digital format and within PAC’s from stocked PAC-CLAD colors and gauges. Trim, gutters 16-17 REDI-ROOF PANELS e-binder on its website. and downspouts can be produced from Petersen’s 45 Technical assistance and service are available and standard PAC-CLAD colors. Redi-Roof Redi-Roof complemented locally by a nationwide organization of SS w/ Offsets SS w/o Offsets PERIMETER/ROOF EDGE SYSTEMS 18-19 PAC-150 PANELS* architectural representatives who can offer assistance in material selection, finish specification and budgeting. Because Petersen’s perimeter/roof edge product line provides the Petersen’s scope of applications is so wide, inquiries are complete system to ensure a clean, sure-fitting product while * Available only from our Georgia and Maryland facilities PAC-150 PAC-150 90˚ Seam 180˚ Seam encouraged. eliminating the need for field fabrication. All PAC perimeter systems are produced in 12’ lengths for an estimated 20 to 20-21 FLUSH/REVEAL WALL PANELS PAC-CLAD ARCHITECTURAL SHEET AND COIL 40 percent savings in material handling over the typical 8’ or PAC-CLAD is a versatile prefinished sheet metal coating of 10’ lengths. Perimeter systems are competitively priced while Flush Panel Reveal Panel 70% full polyvinylidene fluoride (Kynar) that is applied to G-90 providing superior strength, aesthetics and ease of installation. 22-25 PRECISION SERIES WALL PANELS galvanized , galvalume steel or prime quality aluminum. Perimeter products are tested to the standards of ANSI/SPRI/ Originally developed for use in abrasive environments, FM 4435/ES-1, Miami-Dade and FM. For information on our PAC-CLAD has proven to be ideally suited for applications coping and fascia products, please see pages 36-37 of this in roofing, wall, curtainwall, storefront and trim applications. catalog or visit pac-clad.com.

HWP Highline B1 Highline B2 Highline C1 Highline C2 Highline M1 Highline S1 Highline S2 PAC-CLAD is now available in 45 colors carefully selected to complement a range of building materials. 26-27 PRECISION SERIES TILES 28-29 EXPOSED FASTENER PANELS Cape Canaveral Volunteer Fire Station, Cape Canaveral, FL Architect: BRPH General contractor: W&J Construction R-Panel M-Panel 7.2 Panel Corrugated Installing contractor: Quality Metals Profile: Tite-Loc Plus 30 PERFORATED METAL Color: Arcadia Green 31 COLORGARD® SNOW RETENTION SYSTEM 31 COIL AND FLAT SHEET 32-33 SOFFIT PANELS Flush Reveal PAC-850 PAC-750 Solid Soffit

34 COMPOSITE WALL PANELS Cover photo: Ballet Memphis, Memphis, TN 35 FLASHING, TRIM, ANODIZED ALUMINUM Architect: archimania General contractor: Grinder Tabor Grinder 36 FASCIA SYSTEMS Installing contractor: Ralph Jones Sheet Metal Profiles: Snap-Clad, perforated Snap-Clad, 37 COPING SYSTEMS Corrugated, perforated Corrugated Colors: , natural material 38-39 GENERAL CONSIDERATIONS Photo: courtesy of archimania

2 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 3 PAC-CLAD® APPLICATIONS

Jefferson County Western Health Center, Midfield, AL Destin Commons, Destin, FL Owner: Jefferson County Department of Health Owner: Turnberry Associates Architect: Birchfield Penuel & Associates Installing contractor: Roof Specialties General contractor: M.J. Harris Construction Services Architect: JPRA Architects Installing contractor: CSC Roofing Distributor: CRS – Commercial Roofing Specialties Profiles: Tite-Loc curved, Reveal Wall Panels Profiles: Snap-Clad Colors: Cardinal Red, Sierra Tan Colors: Arcadia Green, Slate Gray, Terra Cotta

Discovery Center in the Discovery Park of America, Union City, TN Walls Residence, Little Rock, AR Architect: Verner Johnson Inc. Architect: Polk Stanley Wilcox Architects Contractor: Allen Searcy Builder-Contractor Inc. Installing contractor: Covington Roofing & Sheet Metal Installing contractor: Ralph Jones Sheet Metal Inc. Material: PAC-CLAD 24 ga. steel Profiles: Tite-Loc, Snap-On Color: Musket Gray Color: Silver Metallic

4 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 5 PAC-CLAD® APPLICATIONS

Otto M. Budig Theater, Cincinnati Indian Springs School, Pelham, AL Owner: Cincinnati Shakespeare Co. Architect: Architectureworks Architect: GBBN Architects General contractor: B.L. Harbert General contractor: Messer Construction Installing contractor: Quality Architectural Roofing Installing contractor (roof panels): Tecta America Zero Co. Photography: Casey Dunn Installing contractor (wall panels): ProClad Inc. Profile: Snap-Clad Profiles: 7/8” Corrugated, Perforated Corrugated, Flat Sheet Color: Zinc Colors: Champagne metallic, custom color Classic Bronze metallic

Skyvue Apartments, Pittsburgh Craig Ranch Phase III, McKinney, TX Owner: RISE – A Real Estate Company Owner: Lincoln Property Co. Architect: Niles Bolton Architect: JHP Architecture General contractor: Massaro Corp. General contractor: Amicus Construction Installing contractor: Wyatt Inc. Installing contractor: Stazon Roofing Material distributor: Brock Associates Material distributor: Roofing Supply Group Profiles: Flush, 7/8” Corrugated, Sheet Material: Steel coil Colors: Bone White, Stone White, Colors: Weathered Steel, Zinc Matte Black, Charcoal

6 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 7 PAC-CLAD® COLOR CHART PAC-CLAD® COLOR AVAILABILITY PAC-CLAD 3 YEAR STEEL ALUMINUM ENERGY TRIM COMMITMENT TO SUSTAINABILITY REFLECTIVITY EMISSIVITY SRI STANDARD COLORS EXPOSURE 24 GA. 22 GA. .032 .040 .050 .063 STAR PAC-CLAD products are available in prime quality aluminum PAC-CLAD products provide unmatched aesthetics and AGED BRONZE 0.29 0.86 N/A 29 (.032 - .063), 24 gauge G-90 galvanized steel and 22 gauge performance, plus an element of sustainability. Where ALMOND 0.53 0.87 0.52 62 0.31 0.88 0.32 32 Galvalume steel, finished with a 70% full PVDF (Kynar)finish possible, Petersen products include a high percentage of ARCADIA GREEN AWARD BLUE 0.21 0.86 0.20 17 on the top side, with a washcoat on the bottom. Other metals recycled material, which lowers their environmental footprint. BERKSHIRE BLUE* 0.26 0.87 0.25 25 available include mill finish aluminum, bare galvanized steel, Additionally, PAC products are 100% recyclable which may BLACK ALUMINUM** 0.20 0.86 N/A 17 , Galvalume Plus and anodized aluminum. reduce the solid waste stream to landfills. MATTE BLACK STEEL** 0.22 0.87 0.21 20 BONE WHITE 0.67 0.86 0.64 81 A strippable vinyl film can be applied to coil, flat sheet or Petersen also offers the industry’s widest range of 45 colors, BURGUNDY 0.24 0.87 0.23 23 fabricated parts to protect painted surfaces. Vinyl masking is most of which feature outstanding SRI (Solar Reflectance Index) BURNISHED SLATE 0.32 0.86 33 recommended where extra handling is expected. NOTE: Film values for improved cooling and energy savings performance. CARDINAL RED 0.37 0.86 0.36 39 must be removed immediately after installation. PAC-CLAD offers 28 finishes that are rated by the Cool Roof CHARCOAL 0.27 0.87 0.27 27 ® CITYSCAPE 0.44 0.86 0.43 49 Ratings Council, and 30 colors that are Energy Star -approved. FINISH WARRANTY COLONIAL RED 0.32 0.88 0.32 34 In addition, 30 PAC-CLAD finishes have an SRI of 29 or higher DARK BRONZE 0.26 0.85 0.24 24 Life expectancy is 30-years plus on 70% full PVDF-finished for steep slope roofs, to allow a building to qualify for credits EVERGREEN 0.27 0.86 0.25 26 materials. A 30-year, non-prorated warranty covering color in the U.S. Green Building Council’s Leadership in Energy and FOREST GREEN 0.10 0.87 0.10 6 fade, chalking and film integrity is available at no extra charge. Environmental Design (LEED) Green Building Rating System. GRANITE* 0.32 0.87 0.33 33 Warranty terms vary slightly for Cardinal Red, Award Blue, Refer to pacgreeninfo.com for more information on sustainable GRAPHITE 0.29 0.86 N/A 29 HARTFORD GREEN 0.29 0.86 0.30 29 Weathered Steel and Weathered Copper. cool metal roofing. HEMLOCK GREEN 0.29 0.86 0.30 29 PAC-CLAD METALLICS HUNTER GREEN 0.27 0.86 0.26 26 INTERSTATE BLUE 0.13 0.87 0.12 8 Petersen can supply metallic finishes with the economy of MANSARD BROWN 0.29 0.86 0.27 29 a one-pass, two-coat system at a moderate additional cost. MEDIUM BRONZE 0.26 0.88 0.25 26 Petersen Aluminum has These colors are ideal for all building envelope applications. been a proud partner with MIDNIGHT BRONZE 0.06 0.88 N/A 0 A PAC-CLAD metallic 30-year, non-prorated finish warranty Valspar since 1972 MILITARY BLUE 0.29 0.87 0.28 29 applies. Proper orientation is required as this is a MUSKET GRAY 0.31 0.87 0.30 32 PATINA GREEN 0.33 0.86 0.32 34 directional finish. SANDSTONE 0.49 0.87 0.49 56 SIERRA TAN 0.36 0.87 0.36 39 NOTE: Colors below are not exact representations of actual PAC-CLAD colors. Ask a PAC representative for a color-chip chart or painted metal samples before making final color selection. SLATE BLUE 0.25 0.87 0.24 24 SLATE GRAY 0.37 0.88 0.36 40 STANDARD COLORS PREMIUM COLORS STONE WHITE 0.64 0.87 0.61 77 TEAL 0.26 0.87 0.26 25 TERRA COTTA 0.36 0.88 0.35 39 PAC-CLAD PREMIUM COLORS AGED COPPER 0.26 0.87 0.25 25 ANODIC CLEAR 0.54 0.81 N/A 61 Patina Teal* Hemlock Forest Green Dark Bronze* Midnight Mansard Anodic Clear Silversmith Green* Green* Bronze Brown* CHAMPAGNE 0.40 0.82 0.36 42 COPPER PENNY 0.47 0.87 0.44 53 SILVER 0.49 0.81 0.46 54 SILVERSMITH 0.53 0.81 N/A 60 Arcadia Hartford Evergreen* Hunter Burnished Aged Burgundy Silver* Champagne* WEATHERED COPPER 0.45 0.88 N/A 51 Green* Green Green* Slate Bronze WEATHERED STEEL 0.32 0.89 N/A 34 WEATHERED ZINC 0.26 0.82 0.23 23 ZINC 0.33 0.88 0.32 35

Military Blue Berkshire Slate Blue* Medium Terra Cotta* Colonial Red* Cardinal Red* Weathered Zinc* CLEAR-COAT ACRYLIC FINISH (NON-KYNAR) Blue Bronze* Zinc* GALVALUME PLUS 0.68 0.14 0.55 57

PAC-CLAD Premium finishes are available from stock at a moderate extra cost. PAC-CLAD Copper Penny is a Non-Weathering finish. Solar Reflectance Index calculated according to ASTM E-1980. *Low Gloss/Low Sheen, full 70% PVDF finish ** Appearance differs for Black Aluminum and Matte Black Steel Interstate Award Blue Charcoal* Cityscape Sandstone* Granite* Sierra Tan* Copper Penny* Aged Copper* Blue ` ` ENERGY STAR PERFORMANCE CRITERIA: ` Humidity Resistance (ASTM D 2247): Galvalume or HDG, 100% RH, ` Abrasion Resistance (ASTM D 968): 67 +/- 10 liters `` Emissivity uses ASTM C1371 Reflectivity uses ASTM C1549. 2000 hours – No field blisters; Aluminum, 100% RH, Cross Hatch Adhesion (ASTM D 3359): No loss of adhesion ` TECHNICAL DATA FOR KYNAR 500/HYLAR 5000 COATING: 3000 hours – No field blisters ` Reverse Impact (ASTM D 2794): Galvalume or HDG, 2x ` `` ` South Florida Exposure: Color (ASTM D 2244) - No more than 5ΔE Salt Spray Resistance (ASTM B 117): Aluminum, 3000 hours, metal thickness inch-pounds, no loss of adhesion; Aluminum, Hunter units at 20 years; Chalk (ASTM D 4214) – Rating no less than 8 at Galvalume or HDG, 1000 hours – Creep from scribe no more than 1.5x metal thickness inch-pounds, no loss of adhesion `` Matte Black Graphite Musket Gray* Slate Gray* Bone White* Stone White* Almond* Weathered Weathered 20 years; Film integrity – 20 years. 1/16”, no field blisters Flame Test (ASTM E 84): Class A Coating Copper Steel ` `` ` Accelerated Weathering (ASTM D 4587, ASTM G 154): 5000 Hours; Chemical/Acid Pollution Resistance (ASTM D 1308): Pass * Denotes PAC-CLAD Cool Color `` Chalk, per ASTM D 4214, rating of 6 or better; Color, per ASTM D 2244, T-Bend (ASTM D 4145): 1T – 3T with no loss of adhesion `` < 5ΔE (Hunter Units) color change. Pencil hardness (ASTM D 3363): HB – 2H ` ` Specular Gloss (ASTM D 523) @ 60 degrees: Typical – 20 – 35

8 800-PAC-CLAD | PAC-CLAD.COM PAC-CLAD is a registered trademark of Petersen Aluminum Corp. Kynar 500 is a registered trademark of Arkema Inc. Hylar 5000 is a registered trademark of Solvay Solexis. 2 /2018 800-PAC-CLAD | PAC-CLAD.COM 9 SNAP-CLAD PANELS

Snap-Clad panels feature architectural aesthetics as well recommended in most applications. Contact Petersen for as structural performance. Snap-Clad panels, produced in assistance with details on projects requiring lower slopes. For continuous lengths, are leveled to provide superior flatness and coastal applications, aluminum panels along with stainless feature an optional factory-applied sealant bead for improved steel clips must be used for warranty. Consult a local architect/ weather resistance. Maximum panel length is 64’ and minimum engineer for compliance with local codes and conditions. panel length is 4‘. Consult factory for longer lengths. EAVE NOTCHING

Snap-Clad panels feature a 1-3/4” leg height and a continuous Factory-produced eave notching is available at nominal interlock for improved structural performance and wind additional cost on Snap-Clad panels and Redi-Roof standing resistance. A concealed-fastener clip system allows for thermal seam panels. Factory eave notching saves on labor cost by expansion/contraction while providing extraordinary hold- eliminating the need for field cutting to produce a properly down strength. Two clips are available: a standard clip for most trimmed eave detail. mansard and fascia applications, and a high-performance clip for roofing applications and UL 90-rated assemblies. TRIM

All flashing and trim shall be fabricated by manufacturer or Cabela’s, Gainesville, VA qualified fabricator. Flashing shall be PAC-CLAD aluminum Owner: Cabela’s Inc. (.032 - .063 gauge as specified) or PAC-CLAD steel (24 gauge Architect: CR Architecture + Design General contractor: L.F. Jennings or 22 gauge as specified). A 30-year non-prorated finish Installing contractor: Orndorff & Spaid Profiles: Snap-Clad, S-5! ColorGard warranty can be supplied covering finish performance. Vinyl USE HEMMING TOOL Color: Custom East Georgia Green masking is recommended on all fabrication applications where TO FIELD-BEND NOTCH extra handling is expected. NOTE: The strippable film must be removed immediately after installation. EAVE NOTCH (OPTIONAL) INSTALLATION AT FORMED SEAMS

Snap-Clad panels are intended for use in roofing, mansard and fascia applications. Substrates may include 5/8” (min.) plywood, nailboard insulation or equal with an underlayment UL of ice and water shield applied horizontally from eave to ridge. 90 Other substrates may include metal decking or rigid insulation in conjunction with bearing plates. A minimum 2:12 pitch is SNAP-CLAD

MATERIALS .032 aluminum 24 gauge steel ` ` PRODUCT FEATURES ` 43 stocked colors (24 gauge steel) ` UL-90 rated aluminum panel up .040 aluminum 22 gauge steel `` to 16” O.C. `` 15 stocked colors (22 gauge steel) Architectural/structural panel ` `` ` ` 36 stocked colors (.032 aluminum) UL-90 rated steel panel up SPECS ` Factory-applied sealant available ` to 18” O.C. 10”, 12”, 16” or 18” O.C. 1-3/4” High ` ` 22 stocked colors (.040 aluminum) ` Continuous interlock `` ASTM TESTS `` Panels available in Galvalume Plus Labor-saving one-piece design `` SNAP CLAD ` ASTM E1592 tested ` Stiffener beads upon request UL CLASSIFICATION ` ` ASTM E283/1680 tested `` `` WITH STRIATIONS SMOOTH PANEL Striations upon request UL-580 Class 90 wind uplift `` (OPTIONAL) 1-3/4" (STANDARD) 1-3/4" ` ` ASTM E331/1646 tested ` Factory eave notching available ` UL-1897 wind uplift ` `` FLORIDA BUILDING & MIAMI-DADE PRODUCT10", 12", 16" or 18" O.C. 10", 12", 16" or 18" O.C. ` 30-year non-prorated finish warranty UL-790 Class A fire rated APPROVALS `` `` GiveSNAP Kids the World CLAD Administration Building, Kissimmee, FL Maximum factory-produced panel length UL-263 fire resistance rated Please refer to pac-clad.com or your local Architect: C.T. Hsu & Associates is 64’ (check w/factory for longer lengths) `` General contractor: Welbro Building Corp. UL-2218 impact resistance rated factory for specific product approval Installing contractor: Hartford South `` 1/15/18 Snap Clad - Striation line drawing made/added 1/10/18 Snap Clad - Removed arrow andWITH text “Sealant STRIATIONS bead (optional)” and added “Smooth Panel (Standard) Material distributor:SMOOTH PANEL ABC Supply Weathertightness warranty available numbers for Snap-Clad. 1-3/4" 1-3/4" (OPTIONAL) Profiles: Snap-Clad,(STANDARD) PAC-150 Color: Patina Green 10", 12", 16" or 18" O.C. 10", 12", 16" or 18" O.C.

1/15/18 Snap Clad - Striation line drawing made/added 1/10/18 Snap Clad - Removed arrow and text “Sealant bead (optional)” and added “Smooth Panel (Standard) 10 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 11 TITE-LOC PANELS

PRODUCT FEATURES Lexington Sports Complex, Blaine, MN Owner: City of Blaine, MN `` Architect: Ron Brenner Architects Pencil ribs (stiffening beads) and striations General contractor: Ebert Construction are only available by request Installing contractor: Nordstrom Architectural Sheet Metal UL UL `` Profile: Tite-Loc Plus 90 90 30-year non-prorated finish warranty Color: Charcoal ` ` Maximum factory-produced panel length TITE-LOC TITE-LOC PLUS is 64’ (check w/factory for longer lengths) ` ` Weathertightness warranty available MATERIALS MATERIALS MATERIAL ` .032 aluminum* 24 gauge steel* .032 aluminum* 24 gauge steel* ` 43 stocked colors (24 gauge steel) TITE-LOCTITE-LOC TITE-LOCTITE-LOC PLUS PLUS ` TITE-LOC TITE-LOC HS HS .040 aluminum* 22 gauge steel* .040 aluminum* 22 gauge steel* ` 15 stocked colors (22 gauge steel) SMOOTH PANEL SMOOTH PANEL SMOOTH PANEL SMOOTH PANEL `` SMOOTHSMOOTH PANEL PANEL (OPTIONAL)(OPTIONAL) (OPTIONAL)(OPTIONAL) 36 stocked colors (.032 aluminum) SPECS 2" 2" SPECS 2" 2" 2" 2" `` 12”, 16” or 18” O.C. 2” High 12”, 16” or 18” O.C. 2” High 22 stocked colors (.040 aluminum) ` D D 12", 16" or 18" O.C. ` 12", 16" or 18" O.C. Galvalume Plus12", 16" available12", or 17-5/8" 16" or 17-5/8" O.C. EO.C. TITE-LOCTITE-LOC TITE-LOCTITE-LOC12", 16"12", or 18" 16" O.C. PLUSor 18" O.C.PLUS TITE-LOC TITE-LOC HS HSE UL CLASSIFICATION SMOOTH PANEL SMOOTH PANEL SMOOTH PANEL SMOOTH PANEL SMOOTHWITH STRIATIONSSMOOTH PANEL PANEL WITH(OPTIONAL) STRIATIONS(OPTIONAL) WITH(OPTIONAL) STRIATIONSWITH(OPTIONAL) STRIATIONS `` WITH STRIATIONSNU WITH STRIATIONS 2" 2" UL-580 Class 90(OPTIONAL) rated up toNU 18” O.C. 2" 2" (STANDARD) 2" (STANDARD) 2"2" 2" (OPTIONAL)I 2" (STANDARD) 2" (STANDARD) 2" ` I 2" ` UL-1897 wind uplift D D ` 12", 16"12", or 18" 16" O.C. or 18" O.C. ` UL-790 Class12", A 16" fire12", or 17-5/8" 16"rated or 17-5/8"O.C. O.C. 12", 16" or 18" O.C. 12", 16"12", or 18" 16" O.C. or 18" O.C. 12", 16" or 17-5/8" O.C. E E TITE-LOC12", 16" or 18" O.C. TITE-LOC12", 16"12", or 18" 16" O.C. PLUSor 18" O.C. ` TITE-LOC12", 16" or 17-5/8" HS O.C. TITE-LOC TITE-LOC PLUS ` UL-263 fire resistanceTITE-LOC rated HS ` SMOOTH PANEL SMOOTHWITH PANEL STRIATIONS ` WITHSMOOTH STRIATIONSWITH PANEL STRIATIONS WITH STRIATIONSWITHSMOOTH STRIATIONS PANEL STRIATIONSWITH STRIATIONSW/SMOOTH PENCIL PANELRIBS** UL-2218 STRIATIONSimpactSTRIATIONS resistance W/ PENCIL NUW/ PENCIL RIBS ratedNU RIBS STRIATIONS(OPTIONAL) W/ PENCIL RIBS** STRIATIONS(OPTIONAL)(STANDARD) W/ PENCIL RIBS** CONTCONT(OPTIONAL)SMOOTH(OPTIONAL) PANEL STRIATIONS(STANDARD)(STANDARD)(OPTIONAL) W/ PENCIL RIBS** 2"2" 2" (STANDARD)(OPTIONAL)(OPTIONAL) 2"2" 2" (OPTIONAL)I I 2" 2" 2" (OPTIONAL) 2" (OPTIONAL) 2" 2" (OPTIONAL)(OPTIONAL) 2" 2" 2" TESTS (TITE-LOCS PLUS ONLY) 2" Tite-Loc panels combine structural panel performance with For coastal applications, aluminum panels along with stainless S D `` D architectural panel aesthetics. Tite-Loc panels are leveled to steel clips must be used for finish warranty. Consult a local 12", 16" or 18" O.C. 24 Gauge Steel12", 16" SSTD or 17-5/8" Missile O.C. Impact 12", 16"12", or 18" 16" O.C. or 18" O.C. 12", 16"12", or 18" 16" O.C. or 18" O.C. 12", 16"12", or 17-5/8" 16" or 17-5/8"O.C. O.C. 12", 16"12", or 18"16" O.C.or 18" O.C. 12", 16"12", or 18" 16" O.C. or 18" O.C. DIDI 12", 16"12",12", or 17-5/8" 16"16" oror 17-5/8"17-5/8"O.C. O.C.EO.C. provide superior panel flatness. A factory-applied sealant bead architect/engineer for compliance with local codes and 12", 16" or 18" O.C. 12", 16" or 18" O.C. Tested - Passed E ` can be applied for additional weather resistance. Maximum conditions. ` .032 Aluminum SSTD Missile Impact WITH STRIATIONS STRIATIONSSTRIATIONSWITH W/STRIATIONS PENCIL W/ PENCIL RIBS** RIBS** STRIATIONSCONTWITHSTRIATIONSCONT STRIATIONS W/ PENCIL W/ PENCIL RIBS RIBS STRIATIONSSTRIATIONS W/ PENCIL W/ PENCIL RIBS** RIBS** WITH STRIATIONS (OPTIONAL)WITH(OPTIONAL) STRIATIONSNU PENCIL(STANDARD)WITH RIBS STRIATIONS PENCIL(OPTIONAL)(STANDARD)(OPTIONAL) RIBS 2"2" 2" Tested - Passed(OPTIONAL) NU 2" panel length is 64’ and minimum panel length is 4’. Consult PENCIL(OPTIONAL) RIBS 2"2" 2" PENCIL RIBS 2" (OPTIONAL)I 2"2" (OPTIONAL)(STANDARD) 2" (STANDARD) 2" I 2" TITE-LOC/TITE-LOC PLUS PANELS (OPTIONAL)(OPTIONAL) 2" 2" (OPTIONAL(OPTIONAL - LIMITED - LIMITED AVAILABILITY AVAILABILITY) ) S S factory for longer lengths. ASTM TESTS

Tite-Loc and Tite-Loc Plus panels are factory-formed to 12", 16" or 18" O.C. 12", 16"12", or 18" 16" O.C. or 18" O.C. `` DI 12",12", 16" 16"12", or or 17-5/8" 16" 17-5/8" or 17-5/8"O.C. O.C. O.C. 12", 16"12", or 18" 16" O.C. or 18" O.C. 12", 16" or 18" O.C. ASTMDI E1592 tested 12", 16"12", or 18" 16" O.C. or 18" O.C. 12", 16" or 18" O.C. 12", 16" or 17-5/8" O.C. Tite-Loc panels feature a 2” leg height that requires mechanical 12", 16" or 18" O.C. ` length and field-seamed to a 90° lock (Tite-Loc) or a 180° lock ` ASTM E331/1646 tested field seaming after installation. Panels have a concealed- (Tite-Loc Plus). The panels have been designed for application STRIATIONS W/ PENCIL RIBS** `` STRIATIONSCONT W/ PENCIL RIBS STRIATIONSPENCIL W/ PENCILPENCIL RIBS RIBSRIBS** STRIATIONSPENCIL(OPTIONAL)PENCIL RIBS W/ PENCIL RIBS RIBS** ASTM E283/1680STRIATIONS(OPTIONAL) tested W/ PENCIL RIBS fastener floating clip system designed to allow for thermal Not all panelSTRIATIONS conditions W/ PENCIL RIBS** are available in each Petersen branch; additional freight 2"2" 2" CONT 2" (OPTIONAL)(OPTIONAL) 2"2" 2" (OPTIONAL(OPTIONAL - LIMITED -(OPTIONAL) LIMITED AVAILABILITY AVAILABILITY) ) 2" (OPTIONAL) over a wide variety of substrates on roof slopes as low as (OPTIONAL) 2" `` S 2" charges might apply if specific panel condition is required. Tite-Loc and ASTM E2140S (Tite-Loc Plus only) expansion/contraction. 1/2:12 pitch. Available in 12”, 16” and 18” widths, Tite-Loc and Tite-Loc Plus panels are supplied with “striations” as standard.12", 16" Customeror 18" O.C. must FLORIDA BUILDING12", 16"& orMIAMI-DADE 17-5/8" O.C. PRODUCT 12",12", 16"16"12", oror 18"18" 16" O.C.O.C. or 18" O.C. 12", 16"12", or 18" 16" O.C. or 18" O.C. DI TRIM Tite-Loc Plus panels can be produced in 22 and 24 gauge steel 12", 16" or 18" O.C. 12", 16" or 18" O.C. APPROVALSDI 12", 16" or 17-5/8" O.C. advise if additional panel conditions are required. or .032 and .040 aluminum. All flashing and trim shall be fabricated by manufacturer or Please refer to pac-clad.com or your local PENCIL RIBS PENCIL RIBS 2" factory for specific product approval numbers qualified fabricator. Flashing shall be PAC-CLAD aluminum SEAMING (OPTIONAL)PENCIL RIBS 2" (OPTIONAL - LIMITEDPENCIL AVAILABILITY RIBS ) 2" (OPTIONAL) 2" (OPTIONAL - LIMITED AVAILABILITY) for Tite-Loc Plus. (.032 - .063 gauge as specified) or PAC-CLAD steel (24 gauge The Tite-Loc seamer is bi-directional, offering labor savings 12", 16" or 18" O.C. 12", 16" or 18" O.C. or 22 gauge as specified). A 30-year non-prorated finish with the ability to travel up and down slope. However, the 12", 16" or 18" O.C. 12", 16" or 18" O.C. warranty can be supplied covering finish performance. Vinyl seamer should only be used up slope on roofs with a pitch of masking is recommended on all fabrication applications where *24 gauge and 22 gauge steel and .032 and .040 aluminum panels are 6:12 or less. UL-90 classified over solid substrate. See roof deck construction in extra handling is expected. NOTE: The strippable film must be Underwriter Laboratories roofing materials and systems directory. **24 gauge and 22 gauge Tite-Loc Plus panels are FM Approved in 12” and removed immediately after installation. The Tite-Loc Plus seamer runs in one direction. Tite-Loc Plus 16” widths over 16 gauge open purlins only.

panels should be installed from left to right to ensure the ** Not available in all locations. Consult PAC rep for availability. INSTALLATION seamer travels down slope. The seamer will not travel up slope Tite-Loc panels are intended for use in architectural and on a roof pitch greater than 4:12. structural roofing. Substrates may include 5/8” (min.) plywood, CURVED APPLICATIONS nailboard insulation or equal with an underlayment of ice and water shield applied horizontally from eave to ridge. Other The Tite-Loc panels can be curved to a minimum radius of Cape Canaveral Volunteer Fire Station, Cape Canaveral, FL substrates may include metal decking, purlins or rigid insulation 20’. Tite-Loc curving can be done in the field or at the factory Architect: BRPH depending on the radius and length of the panel. General contractor: W&J Construction in conjunction with bearing plates. A minimum 1/2:12 pitch is Installing contractor: Quality Metals required. Contact Petersen for further assistance with Profile: Tite-Loc Plus For more details about Petersen’s curving capabilities, please Color: Arcadia Green projects details. contact your local Petersen factory.

12 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 13 SNAP-ON PANELS

Charleston Harbor Resort, Mount Pleasant, SC Owner: Brothers Property Management Corp. The simplicity of the pan design combined with leveling Architect: Glick Boehm Bells Mill Elementary School, Potomac, MD General contractor: Hogan Construction Owner: Montgomery County Public Schools provides superior flatness and allows for greater workability Architect: Walton, Madden, Cooper, Robinson, Poness Inc Installing contractor: Achelpohl Roofing General contractor: Oak Contracting on site. Profiles: Tite-Loc Plus, Snap-On, PAC-150 Installing contractor: CitiRoof Corporation Color: Silver Profile: Snap-On Batten Colors: Hemlock Green, Colonial Red, TRIM Sandstone, Slate Gray All flashing and trim shall be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032 - .063 gauge as specified) or PAC-CLAD steel (24 gauge or 22 gauge as specified). A 30-year non-prorated finish warranty can be supplied covering finish performance. Vinyl masking is recommended on all fabrication applications where extra handling is expected. NOTE: The strippable film must be removed immediately after installation. INSTALLATION

Snap-On panels shall be installed over solid decking (5/8” plywood, nailboard insulation or equal) with an underlayment applied horizontally from eave to ridge. Panels shall be fastened using Petersen nonpenetrating clips, fastening on 18” centers (max.). Minimum slope at 3:12 pitch. Consult a local architect or engineer for requirements of local codes and conditions. CURVED PANELS

The 1” high Snap-On standing seam panel can be curved to a concave or convex radius, with a minimum radius of 9’. This panel is ideal for barrel vaults and entrance ways. Curved panels must be installed over a waterproofed solid substrate.

Snap-On panels are ideal for use in roofing, mansard UL UL and fascia applications. Snap-On panels are designed to be 90 90 SNAP ON installed over a waterproofed solid substrate and a minimum SNAP-ON SNAP-ON HIGH SNAP-ON 3:12 roof pitch. Snap-On panels are factory roll-formed in STANDING SEAM BATTEN STANDING SEAM 1" continuous lengths. Maximum panel length is 35’ and minimum 12”, 18”, 19" or 20" O.C. panel length is 4’. Consult factory for nonstandard lengths. MATERIALS MATERIALS SNAP ON MATERIALSSnap On Standing Seam .032 aluminum 24 gauge steel* .032 aluminum 24 gauge steel .032 aluminum 24 gauge steel* 1" SPECS SPECS SPECS 1-1/2" `` ASTM TESTS 12”, 18”, 19" or 20" O.C. PRODUCT FEATURES 36 stocked colors (.032 aluminum) 12”, 18”, 19” or 20” O.C. 1” High 11”, 12”, 13”, 18” 1-1/2” High 11”, 18” or 19” O.C. 1-1/2” High `` `` 11", 12", 13", 18" or 19" O.C. ** `` Galvalume Plus available ASTM E283/1680 tested or 19” O.C.**Snap On Standing Seam Ideal for transition roofs ` ` UL CLASSIFICATION ` ASTM E331/1646 tested Snap On Batten ` Stiffener beads available SNAP ON ` `` ` UL-580 Class 90 rated over solid FLORIDA BUILDING PRODUCT APPROVALS 30-year non-prorated finish warranty 1-1/2" 1-1/2" ` substrate. (steel only - up to 18” O.C.) 1" ` Panel lengths up to 35’ Please refer to pac-clad.com or your local `` UL-1897 wind uplift factory for specific product approval num- 12”, 18”, 19" or 20" O.C. 11", 12", 13", 18" or 19" O.C. ** 11", 18" or 19" O.C. MATERIAL ` bers for Snap-On Panels. ` UL-790 Class A fire rated `` Snap On Standing Seam Snap On Batten High Snap On Standing Seam 43 stocked colors (24 gauge steel) `` UL-263 fire resistance rated *12” and 18” 24 gauge steel Snap-On Standing Seam panels & 11” and 18” 24 gauge steel High Snap-On Standing Seam panels are UL-90 Classified over solid substrate. See roof deck construction in Underwriter Laboratories roofing materials and systems directory. 1-1/2"

1-1/2" ** Panel width varies by factory. Consult PAC rep for details. 11", 18" or 19" O.C. 11", 12", 13", 18" or 19" O.C. ** A complete specification is available online at pac-clad.com. High Snap On Standing Seam Snap On Batten

1-1/2" 14 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 15 11", 18" or 19" O.C.

High Snap On Standing Seam REDI-ROOF PANELS

Redi-Roof may be specified in either a batten or standing-seam profile and is intended for application over a solid substrate with a minimum 3:12 roof pitch. Typical substrates include plywood, nailboard insulation or equal. Panels are factory roll- formed in continuous lengths. Maximum panel length is 45’ and minimum panel length is 4’.

Redi-Roof panels feature an offset profile which adds strength and allows room for a hex head fastener. The clip, with its button-punched design, ensures an extra-snug fit. The one- piece design allows for ease of installation. TRIM

All flashing and trim shall be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032 - .063 gauge as specified) or PAC-CLAD steel (24 gauge or 22 gauge as specified). A 30-year non-prorated finish warranty can be supplied covering finish performance. Vinyl masking is recommended on all fabrication applications where extra handling is expected. NOTE: The strippable film must be removed immediately after installation. INSTALLATION

Redi-Roof panels shall be installed over solid decking with an underlayment applied horizontally from eave to ridge. Photo above: Panels shall be fastened using Petersen nonpenetrating Fields Residence, Downers Grove, IL clips, fastening on 18” centers (max.). Minimum slope at 3:12 Architect: Kuklinski+Rappe Architects General contractor: Roberts Design+Build pitch. Redi-Roof batten panels cannot be lapped in the field. Installing contractor: Complete Flashings Photography: Tom Harris Consult a local architect/engineer for requirements of local Profile: Redi-Roof codes and conditions. Color: Weathered Zinc UL UL 90 90 REDI-ROOF STANDING REDI-ROOF STANDING SEAM WITH OFFSETS SEAM WITHOUT OFFSETS

MATERIALS MATERIALS MATERIAL `` PRODUCT FEATURES UL-263 fire resistance rated .032 aluminum 22 gauge steel .032 aluminum 22 gauge steel `` `` `` 43 stocked colors (24 gauge steel) UL-2218 impact resistance rated 24 gauge steel* 24 gauge steel*REDI-ROOF Available with or without offsets ` `` ` 36 stocked colors (.032 aluminum) ASTM TESTS Factory eave notching available WITH OFFSETS `` ` SPECS SPECS 1-9/16" `` 15 stocked colors (22 gauge steel) ` ASTM E283/1680 tested Labor-saving one-piece design ` 12”, 16” or 18” O.C. 1-9/16” High 12”, 16” or 18” O.C. 1-3/8” High ` ` Galvalume Plus available `` ` Stiffener beads available ASTM E331/1646 tested 12", 16" or 18" O.C. `` UL CLASSIFICATION 30-year non-prorated finish warranty REDI-ROOF Redi-Roof Standing Seam W/Offsets ` `` ` Panel lengths up to 45’ UL-580 Class 90 wind uplift (steel only) ` WITH OFFSETS ` UL-790 Class A fire rated 1-9/16" WITHOUT OFFSETS 1-3/8"

12", 16" or 18" O.C. 12", 16" or 18" O.C.

Redi-Roof Standing Seam W/Offsets Redi-Roof Standing Seam W/OUT Offsets Photo above: Installing contractor: Nations Roof Lilburn Branch Library and City Hall, Lilburn, GA Material distributor: Commercial Roofing Specialties MADE ONLY IN WITHOUT OFFSETS Owner: City of Lilburn, GA Profiles: Tite-Loc Plus 1-3/8" MARYLAND LOCATION 1-1/4" Architect: Precision Planning Color: Sierra Tan *24 gauge steel, in all O.C.’s is UL-90 Classified over solid substrate. See roof deck construction in Underwriter Laboratories roofing materials and systems directory. General contractor: Hogan Construction Group A complete specification12", 16" is availableor 18" O.C. online at pac-clad.com. 12" O.C.

Redi-Roof Standing Seam W/OUT Offsets Redi-Roof Batten

MADE ONLY IN 16 800-PAC-CLAD | PAC-CLAD.COM MARYLAND LOCATION 1-1/4" 800-PAC-CLAD | PAC-CLAD.COM 17

12" O.C.

Redi-Roof Batten PAC-150 PANELS

PRODUCT FEATURES ` ` 30-year non-prorated finish warranty ` ` Available in four pan variations; smooth, striated, pencil rib or flat rib. Check locally PAC-150 PAC-150 for panel condition availability ` 90˚ SEAM 180˚ SEAM ` Maximum panel length of 64’ when factory or shop-formed but virtually unlimited when field-formed ` MATERIALS MATERIALS ` Mechanically seamed in the field to 90° or 180° .032 aluminum 24 gauge steel .032 aluminum 24 gauge steel `` .040 aluminum 22 gauge steel .040 aluminum 22 gauge steel NOTE: Seamers for PAC-150 are not available from Petersen SPECS SPECS MATERIAL 12”, 16”, 18” ` 12”, 16”, 18” ` 43 stocked colors (24 gauge steel) or 20”PAC-150 O.C.PAC-150 90°1-1/2” 90° High or 20” O.C.PAC-150PAC-150 180°1-1/2” 180° High ` ` 15 stocked colors (22 gauge steel) ` ` 36 stocked colors (.032 aluminum) ` ` 22 stocked colors (.040 aluminum) SMOOTHSMOOTH PANEL PANEL SMOOTHSMOOTH PANEL PANEL (STANDARD)(STANDARD) 1-1/2" 1-1/2" (STANDARD)(STANDARD) 1-1/2" 1-1/2" ` ` Galvalume Plus available UL CLASSIFICATION 12" thru12" 20" thru O.C. 20" O.C. 12" thru12" 20" thru O.C. 20" O.C. ` ` UL-580 `` FLAT RIBSFLAT RIBS 1-1/2" 1-1/2" FLAT RIBSFLAT RIBS 1-1/2" 1-1/2" UL-1897 ` ` TAS-125 12" thru12" 20" thru O.C. 20" O.C. 12" thru12" 20" thru O.C. 20" O.C. FLORIDA BUILDING PRODUCT APPROVALS

PENCILPENCIL RIBS RIBS 1-1/2" 1-1/2" PENCILPENCIL RIBS RIBS 1-1/2" 1-1/2" Contact the Acworth, Georgia facility for PAC-150 product approvals.

12" thru12" 20" thru O.C. 20" O.C. 12" thru12" 20" thru O.C. 20" O.C.

Photo below: Westminster Woods, Jacksonville, FL STRIATIONS STRIATIONS STRIATIONS 1-1/2" 1-1/2" STRIATIONS 1-1/2" 1-1/2" Owner: Westminster Communities of Florida Architect: Basham & Lucas Design Group Installing contractor: Mac Johnson Roofing PAC-150 standing seam metal roofing panels combine semi- REGIONAL AVAILABILITY 12" thru12" 20" thru O.C. 20" O.C. 12" thru12" 20" thru O.C. 20" O.C. Profile: Snap-Clad Color: Galvalume structural metal panel performance with architectural roofing PAC-150 is produced only in Georgia and Maryland facilities; panel aesthetics. PAC-150 roofing coil for field-forming additional freight charges might apply. operations is leveled to provide superior panel flatness. Maximum panel length is limited when factory or shop-formed CURVED APPLICATIONS but virtually unlimited when field-formed; minimum panel The PAC-150 panels can be curved to a minimum radius of 10’. length is approximately 4’. Curving can be done in the field or at the factory depending on the radius and length of the panel. For details about curving PAC-150 roofing panels feature a 1.5” leg height which requires capabilities, please contact the Acworth, Ga., or Annapolis mechanical field seaming to either 90° or 180° depending on Junction, Md., factories. the project’s uplift requirements. Panels have a concealed- fastener clip designed to allow for maximum design flexibility. SEAMERS For further details, please contact a Petersen rep. Seamers for PAC-150 are not available from Petersen. This panel combines an attractive thin-rib profile with superior Photo above: structural performance. PAC-150 panels are designed for Bradenton Yacht Club, Palmetto, FL Architect: Garry Roberts Architecture application over a wide variety of substrates in slopes as low General contractor: Matthews Construction as 1/2:12 pitch. PAC-150 roofing panels are available in a wide Installing contractor: Crowther Roofing Material distributor: ABC Supply variety of widths from 12” to 20”. Materials available include 22 Profiles: Snap-Clad Colors: Interstate Blue and 24 gauge steel plus .032 and .040 aluminum.

18 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 19 FLUSH/REVEAL WALL PANELS

Flush panels are designed for wall, fascia and soffit applications panels must be fastened (stitched) through side joints. Consult Goose Creek High School, Goose Creek, SC Owner: ​​​Berkeley County School District where a flush or flat appearance is desired. A rounded interlock a local architect/engineer for requirements of local codes and Architect: SGA Architecture leg and concealed fastening system improves the flush conditions. General Contractor: Thompson Turner Construction Installing contractor: ​Glasgow Roofing appearance while providing additional strength. Panels are Distributor: Roofer’s Supply of Greenville LEVELING Profiles:​​ HWPC, Flush Panel with pencil ribs factory-formed to length to minimize field cutting. Maximum Color: ​​​ Silver panel length is 25’ and minimum panel length is 4’. Petersen’s Flush panels are formed on precision roll-forming equipment that includes levelers. Leveling removes typical Flush panels are available in on-center dimensions designed to metal conditions including coil set, crowning and edge wave. complement Petersen’s roofing panel product line. Flush panels Leveling is available at no extra charge. are available in Flush and Reveal joint configurations. TRIM STIFFENING BEADS All flashing and trim shall be fabricated by manufacturer or The Flush and Reveal panels are available with optional qualified fabricator. Flashing shall be PAC-CLAD aluminum stiffening beads. Stiffening beads are recommended for (.032 - .063 gauge as specified) or PAC-CLAD steel (24 gauge longer panel lengths. One or two beads are available. or 22 gauge as specified). A 30-year non-prorated finish INSTALLATION warranty can be supplied covering finish performance. Vinyl masking is recommended on all fabrication applications where Flush panels shall be installed over a solid substrate with extra handling is expected. appropriate ice and water shield, or in limited applications over framing sections. When used in a windscreen application,

PRODUCT FEATURES ` ` Leveled for flatness `` Skyvue Apartments, Pittsburgh Available with up to two stiffener Owner: RISE – A Real Estate Company beads Architect: Niles Bolton `` General contractor: Massaro Corp. FLUSH PANEL REVEAL PANEL Rounded interlock leg provides Installing contractor: Wyatt Inc. improved flush fit Material distributor: Brock Associates ` Profiles: Flush, 7/8” Corrugated, Sheet ` 30-year non-prorated finish warranty Colors: Bone White, Stone White, Matte Black, Charcoal `` MATERIALS MATERIALS Panel lengths from 4’ to 25’ .032 aluminum 24 gauge steel .032 aluminum 24 gauge steel MATERIAL .040 aluminum* 22 gauge steel* .040 aluminum* 22 gauge steel* `` Wall Panels 43 stocked colors (24 gauge steel) REVEAL `` SPECS SPECS Wall Panels 15 stocked colors (22 gauge steel) REVEAL `` 7”, 11”, or 12” O.C.FLUSH 1” HighWall Panels 7”, 11”, or 12” O.C. 1” High 36 stocked colors (.032 aluminum) FLUSH Wall Panels 1" ` REVEAL Wall Panels ` 22 stocked colors (.040 aluminum) 1" ` 7", 11" or 12" O.C. 1-1/2" ` Galvalume Plus available 1" 1" 1" 7", 11" or 12" O.C. 1-1/2" 1" ASTM TESTS - FLUSH 7", 11" or 12" O.C. Smooth 7", 11" or 12" O.C. ` 7", 11" or 12" O.C. ` 7", 11" or 12" O.C. 1-1/2" ASTM E330 tested - 12" only Smooth ` Smooth ` ASTM 1592 Smooth Smooth `` 1" ASTM E283 ` 1" ` 1" 1" ASTM E331 1" 7", 11" or 12" O.C. 1-1/2" `` 7", 11" or 12" O.C. AAMA 501.1-05 7", 11" or 12" O.C. 7", 11" or 12" O.C. 7", 11" or 12" O.C. 1-1/2" 1" w/ One Stiffener Bead (Optional) FLORIDA BUILDING PRODUCT APPROVALS w/ One Stiffener Bead (Optional) w/ One Stiffener Bead (Optional) w/ One Stiffener7", 11" or 12" Bead O.C. (Optional)1-1/2" Please refer to pac-clad.com or your local factory for specific product 1" 1" 1" w/ One Stiffener Bead (Optional) approval numbers for Flush panels. 1" 11" or 12" O.C. 1" 11" or 12" O.C. 11" or 12" O.C. 1-1/2" 11" or 12" O.C. w/ Two Stiffener Beads (Optional) 11" or 12" O.C. 1-1/2" 1" w/ Two Stiffener Beads (Optional) w/ Two Stiffener Beads (Optional) *Limited color availability. 12” O.C. has reduced w/ Two Stiffener Beads (Optional) fastening flange. A complete specification is available w/ Two Stiffener11" or 12" Beads O.C. (Optional)1-1/2" online at pac-clad.com.

w/ Two Stiffener Beads (Optional)

20 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 21 PRECISION SERIES WALL PANELS PRECISION SERIES - Catalog Use Precision Series architectural wall panels provide design 1-3/8” deep, and can be intermixedNew 12/13 - Shrink to downadd webvisual versions intensity to consistant to size a for catalog use *NEW* flexibility by combining bold visual effects with easy, cost- building’s exterior. Precision Series wall panels can be installed effective installation. Multiple profiles are available with a horizontally or vertically. Consult Petersen rep for maximum variety of rib patterns. Options for each profile includePRECISION a no-clip SERIESlength; minimum - Catalog panel length Useis 4’. Additionally, these wall panel, or a clip-fastened panel to accommodate expansion and panels can be specified as perforated in aluminum only for use New 12/13 - Shrink down web versions to consistant size for catalog use contraction. The original Precision Series HWP profile features in equipment screen applications*NEW* or over graphics as seen a 7/8” depth, while the Precision Series Highline profiles are on page 24. 7/8” PRECISION SERIES - Catalog Use 12" or 16" NOMINAL HWP New 12/13 - Shrink down web versions to consistant size for catalog use *NEW*

7/8” 12" or 16" NOMINAL HWP 1-3/8” Highline B1 PRECISION SERIES - Catalog Use11.356” NOMINAL New 12/13 - Shrink down web versions to consistant size for catalog use *NEW*

7/8” 1-3/8” Highline B2 12" or 16" NOMINAL HWP 1-3/8” Highline B1 HIGHLINE C1 HIGHLINE C2 HIGHLINE 15.356"M1 NOMINAL 11.356” NOMINAL WITH OR WITHOUT CLIP WITH OR WITHOUT CLIP WITH OR WITHOUT CLIP

PRODUCT FEATURES 22’ maximum for aluminum on the thru- TESTS PRECISION SERIES - Catalog Use fastened leg; longer lengths available ` MATERIALS MATERIALS 7/8” MATERIALS 1-3/8” ` ` ASTM E330 New 12/13 - Shrink down web versions to consistant size for 1-3/8”catalog use Highline B1 1-3/8” Highline B2 Highline C1 ` 12" or 16" NOMINAL No-clip panel, or clip installation for on clip panels .032 aluminum 24 gauge steel .032 aluminum*NEW*15.356" NOMINAL24 gauge steel HWP `` 11.356” NOMINAL .032 aluminum11.356" NOMINAL24 gauge steel expansion/contraction ASTM E283 ` MATERIAL `` .040 aluminum 22 gauge steel .040 aluminum 22 gauge steel .040 aluminum 22 gauge steel ` Multiple rib patterns provide a variety of ASTM E331 `` ` .050 aluminum .050 aluminum .050 aluminum looks and design options 43 stocked colors (24 gauge steel) ` AAMA 501.1-05-B1, B2, C2, S1 ` ` Panel depths of 7/8” or 1-3/8” `` `` SPECS 1-3/8” SPECSHighline B2 1-3/8” 1-3/8” Highline C2 36 stocked colors (.032 aluminum) ASTM 1592 1-3/8” SPECSHighline C1 ` 15.356" NOMINAL Highline15.356" B1 NOMINAL ` Cost-effective installation `` 11.356” Wide 1-3/8” High 15.356” Wide11.356" NOMINAL1-3/8” High 15 stocked colors (22 gauge steel) FLORIDA BUILDING PRODUCT APPROVALS 11.356” NOMINAL 12.043” Wide 1-3/8” High `` ` 7/8” Horizontal or vertical installation ` 22 stocked colors (.040 aluminum) Please refer to pac-clad.com or your local 12" or 16" NOMINAL HWP `` `` Panel lengths: 29 stocked colors (.050 aluminum) factory for specific product approval 30' maximum for steel; ` 1-3/8” 1-3/8” 1-3/8” Highline M1 ` Galvalume Plus available numbers for Precision Series panels. Highline C1 1-3/8” Highline C2B2 11.356" NOMINAL 15.356" NOMINAL 12.043” NOMINAL

1-3/8” Highline B1 11.356” NOMINAL PRECISION SERIES - Clip Detail 1-3/8” Highline C2 1-3/8” Highline M1 1-3/8” Highline S1 1-3/8” Highline JOINTC1 DETAILS 15.356" NOMINAL *NEW* 12.043” NOMINAL 11.356" NOMINAL 11.356" NOMINAL PRECISION SERIES - Catalog Use 1-3/8” Highline B2 15.356" NOMINAL New 12/13 - Shrink down web versions to consistant size for catalog use *NEW* 1-3/8” 1-3/8” Highline M1 PRECISION1-3/8” Highline SERIES S1 - Nail FlangeHighline Detail S2 Highline C2CLIP DETAIL 12.043” NOMINAL 15.356"CLIP NOMINAL 115.356"1.356" NOMINALNOMINAL HWP HIGHLINE B1 HIGHLINE B2 HIGHLINE S1 HIGHLINE S2 PRECISION SERIES - Catalog Use 1-3/8” Highline C1 WITH OR WITHOUT CLIP WITH OR WITHOUT CLIP WITH OR WITHOUT CLIP WITH OR WITHOUT CLIP WITH OR WITHOUT CLIP New 12/13 - Shrink down web versions to consistant size for catalog use *NEW* 11.356" NOMINAL Note: Minimum panel length is 5’ 1-3/8” Note:Highline Minimum S1 panel length is 5’ 1-3/8” Highline S2M1 11.356" NOMINAL 15.356" NOMINAL NAIL FLANGENAIL FLANGE DETAIL MATERIALS MATERIALS MATERIALS 7/8” 12.043” NOMINAL 12" or 16" NOMINAL HWP MATERIALS MATERIALS .032 aluminum 24 gauge steel .032 aluminum 24 gauge steel .032 aluminum 24 gauge steel 1-3/8” Highline C2 .032 aluminum 24 gauge steel .050 aluminum 22 gauge steel Photo on page 22: .040PRECISION aluminum 22SERIES gauge steel - Catalog.040 Use aluminum 22 gauge steel .040 aluminum 22 gauge steel 15.356" NOMINAL Herrington-Ornelas HealthPark .040 aluminum 22 gauge steel 1-3/8” Owner: Christus Trinity Mother Frances Health System .050New 12/13 aluminum - Shrink down web versions to consistant size for catalog use .050 aluminum .050 aluminum Highline S2 1-3/8” *NEW* SPECS Architect:Highline HC Architects S1 7/8” .050 aluminum15.356" NOMINAL 11.356" NOMINAL General contractor: WRL General Contractors SPECS SPECS 12" or 16" NOMINAL SPECS 15.356” Wide 1-3/8” High Installing contractor: Tyler Roofing HWP 1-3/8” Highline B1 SPECS 1-3/8” Highline M1 Profiles: Snap-Clad, HWP, Flush, Custom Coping 12” or 16” Wide 7/8” High 11.356” Wide 1-3/8” High 15.356” Wide11.356” NOMINAL1-3/8” High Colors: Champagne, Dark Bronze 11.356” Wide12.043” NOMINAL1-3/8” High 1-3/8” Highline S2 Note: Line drawings on these 15.356" NOMINAL 1-3/8” pages are not to scale. 7/8” Highline B1 1-3/8” Highline B2 1-3/8” 12" or 16" NOMINAL HWP 11.356” NOMINAL 15.356" NOMINAL Highline S1 11.356" NOMINAL

22 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 23 1-3/8” Highline B2 1-3/8” Highline C1 15.356" NOMINAL 1-3/8” 1-3/8” Highline S2 Highline B1 11.356" NOMINAL 11.356” NOMINAL 15.356" NOMINAL

1-3/8” Highline C1 1-3/8” Highline C2 1-3/8” Highline1 1B2.356" NOMINAL 15.356" NOMINAL 15.356" NOMINAL

1-3/8” Highline C2 1-3/8” Highline M1 1-3/8” 15.356" NOMINAL Highline C1 12.043” NOMINAL 11.356" NOMINAL

1-3/8” Highline M1 1-3/8” Highline S1 1-3/8” Highline 12.043”C2 NOMINAL 11.356" NOMINAL 15.356" NOMINAL

1-3/8” Highline S1 1-3/8” Highline S2 1-3/8” Highline1 M11.356" NOMINAL 15.356" NOMINAL 12.043” NOMINAL

1-3/8” Highline S2 1-3/8” Highline 15.356"S1 NOMINAL 11.356" NOMINAL

1-3/8” Highline S2 15.356" NOMINAL PAC-CLAD® WALL PANEL APPLICATIONS

AISD Performing Arts Center, Austin, TX IMG Academy, Bradenton, FL Grammy Museum of Mississippi, Cleveland, MS Owner: Austin Independent School District Architect: Fawley-Bryant Owner: Cleveland Music Foundation Architect: Pfluger Associates Architects General contractor: Tandem Construction Architect: Dale Partners Architects General contractor: American Constructors Installing contractor: Sutter Roofing Co. Installing contractor: Ralph Jones Sheet Metal Installing contractor: Texas Roofing Co. Distributor: ABC Supply Profiles: ½-in. Corrugated, Tite-Loc Plus, Profiles: Flush Panels, M-42 Panel Profiles: Highline S1 Flush Panels, 7.2 Panel perforated Colors: Burgundy, Colonial Red Colors: Cityscape, Musket Gray Colors: Weathered Zinc, Bone White, Terra Cotta, Galvalume custom color Olive

Moving Everest Charter School, Chicago, IL Owner: By The Hand Architect: Team A General contractor: Novak Installing contractor: WBR Roofing Profiles: 7/8-in. corrugated, 7/8-in. perforated Color: Charcoal

Craig Ranch Phase III, McKinney, TX Owner: Lincoln Property Co. Architect: JHP Architecture Private Residence, Wimberley, TX General contractor: Amicus Construction Architect: Carson Design Associates Installing contractor: Stazon Roofing Installing contractor: Dean Contracting Co. Material distributor: Roofing Supply Group Profiles: Snap-Clad, Precision Series Wall Panel, Composite Panels Material: Steel coil Color: Galvalume Colors: Weathered Steel, Zinc Tom Harris @ Hedrich Blessing

24 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 25 PRECISION SERIES TILES

The Precision Series Tiles collection from Petersen includes four as the small size of each tile means movement will be minimal. metal tile profiles that offer designers, specifiers and installers Only basic sheet metal tools are required to work with these an alternative to roll-formed panel-style cladding. The stamped products. Minimum slope of 3:12 for roof applications. tiles can be applied to roof or wall installations, and are offered in four styles including Flat, Cupped, Diamond and TS. Designed PRODUCT FEATURES ASTM TESTS to enhance architectural design, the tiles add dimension to the ` MATERIAL ` ASTM E283 exterior of any structure. The tiles can be applied to either non- ` ` ASTM E330 residential or residential environments, and are covered by the `` 43 stocked colors `` PAC-CLAD 30-year finish warranty. (24 gauge steel) ASTM E331 ` ` 36 stocked colors UL CLASSIFICATION The interlocking tiles are formed using progressive tooling (.032 aluminum) `` ` UL 580-1897 to create a uniform and cost-effective cladding solution. This ` 12 colors (LIC stainless) PRODUCT FEATURES ` AAMA TESTS system installs directly over plywood or elevated channels ` Zalmag(R) coated steel MATERIAL `` using concealed fasteners. No sealant is required for the tiles’ (26 gauge) AAMA 501.1 ` ` 43 stocked colors breathable joints. Thermal gain and movement is not an issue, (24 gauge steel) ` ` 36 stocked colors (.032 aluminum) ` ` 12 colors (LIC stainless) CUPPED TILE FLAT TILE ` DIAMOND TILE TS TILE ` Zalmag(R) coated steel (26 gauge)

ASTM TESTS Project: Federal Center South - U.S. Army Corps of Engineers ` Profile: TS Tile ` ASTM E283 `` Project: Village School - private school ASTM E330 Profile: Diamond Tile `` ASTM E331 CUPPED TILE UL CLASSIFICATION `` The cupped tile catches light at multiple angles that UL 580-1897 creates a multi-shade effect as viewing perspective AAMA TESTS changes. In roof applications, installers can safely `` walk on the cupped tiles during installation. AAMA 501.1 ` ` Nominal: 15” x 9-5/8” Project: Print Shop - Cambridge, MA `` Profile: Flat Tile Exposed: 14-1/2” x 8-5/16” +/- 1/16” FLAT TILE

The flat tile has the flexibility to integrate with both modern and traditional designs. ` ` Nominal: 15” x 9-5/8” ` ` Exposed: 14-1/2” x 8-5/16” +/- 1/16”

DIAMOND TILE

Diamond tiles can be installed horizontally, or on an angle to achieve a diamond or clapboard pattern. ` ` Nominal: 8-5/16” x 9-3/4” ` ` Exposed: 7-1/4” x 8-5/16” +/-1/16”

TS TILE

The TS tile’s larger height creates a vertically oriented pattern. ` ` Nominal: 7-3/4” by 17-1/4” ` ` Exposed: 7-1/4” by 16-1/4” +/- 1/16”

26 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 27 EXPOSED FASTENER

13-21/32" 1"

1-1/4" R-41 DISCONT41” INUED

12" R-36 EXPOSED FASTENER PANELS 1-1/4" 36” EXPOSED FASTENER 6" 1" 13-21/32" 1" 3/4" M-42 EXPOSED FASTENER1-1/4" R-41 42” 41” EXPOSED FASTENER DI13-21/32"SCONT1" INUED

12" 1-1/4" 13-21/32" 1" R-41 6" 1-1/32" 41” 1-1/4" R-36 1-1/4" R-41DISCONTINUED 3/4" M-36 36” 41” 36” R-36DI SPANELCONTINUED M-4212" PANEL* 7.2 PANEL 1-1/4" R-36 12" 7.2" 6" 1" 36” 1-1/4" R-36 EXPOSED FASTENER 3/4" M-42 1-1/2" 7.2 36” 42” 13-21/32" 1" 36” 6" 1" 1-1/4" R-41 Note: Made only in Tyler, Texas facility 41” 3/4" 6" 1" DISM-42CONTINU44.5”ED 42” 42.67” COVERAGE WITH 1 LAPPED RIB FOR SIDING 6" 1-1/32" 12" 3/4" M-42 40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 1-1/4" R-36 42” M-36 PANEL* 3/4" M-36 2.667” 1/2” 36” 36” 6" 1-1/32" 1/2” Corrugated 7.2" 6" M-361" 6" 1-1/32" 3/4" 39.75” 36” 3/4" M-42 1-1/2" 37.33” COVERAGE WITH 1 LAPPED RIB FOR SIDING 3/4" M-36 7.234.67”42” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 36” 36” 2.667” 7/8” 7.2" EXPOSED FASTENER 7.2" 44.5” 1-1/2" 6" 7.2 1-1/32" 7/8” Corrugated 36” 13-21/32" 1" 42.67” COVERAGE WITH 1 LAPPED RIB FOR SIDING 3/4" M-36 1-1/2" 7.240” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 36” 1-1/4" R-41 36” 2.667” 6/8/17 - JESSICADI - changedS 1/2”CONT Corrugated41” +1/2” 7/8I CorrugatedNUE widthD decimals to fractions. 44.5” 7.2" 42.67” COVERAGE1/2” WITH Corrugated 1 LAPPED RIB FOR SIDING 12" 40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 1-1/2" 7.2 44.5” 1-1/4" R-36 36” 42.67” COVERAGE WITH 1 LAPPED RIB FOR SIDING 39.75”2.667” 1/2” 40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 36” 37.33” COVERAGE WITH 1 LAPPED RIB FOR SIDING 2.667” 34.67” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 1/2” 1/2” Corrugated 44.5” 2.667” 42.67” COVERAGE6" WITH1" 1 LAPPED7/8” RIB FOR SIDING 1/2” Corrugated 39.75” 40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING Petersen offers a complete line of exposed fastener panels, allowing for 2.667” 3/4" M-42 37.33” COVERAGE WITH 1 LAPPED RIB FOR SIDING 1/2” 42” creative design flexibility in a cost-effective yet architecturally attractive metal 39.75” 34.67” COVERAGE7/8” WITH Corrugated2 LAPPED7/8” RIBS FOR CORRUGATED ROOFING PRODUCT FEATURES 37.33” COVERAGE WITH 1 LAPPED RIB FOR SIDING 2.667” 1/2” Corrugated 7/8” panel. The versatile 7.2 panel, R-36 and 7/8” Corrugated panels can be specified 34.67” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING 39.75” `` 2.667” 6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions. 30-year non-prorated finish warranty 7/8” 37.33” COVERAGE6" WITH1-1/32" 1 LAPPED RIB FOR SIDING for a wide range of building envelope applications including roofs, walls and 7/8” Corrugated 34.67” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING M-36 `` 2.667” 3/4" Matching screws and rivets 7/8” linear panels. The M-36, M-42 and 1/2” Corrugated panels are suitable for wall 7/8” Corrugated 36” `` 6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions. and equipment screen projects. Closure strips available 7/8” Corrugated `` 7.2" Precut short lengths (5’-0” minimum) 6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions. 1-1/2" TRIM 6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions. 7.2 (3’-0” on the M-42) 1/2” CORRUGATED 36” ` All flashing and trim shall be fabricated by manufacturer or qualified fabricator. ` Panel lengths up to 30’ on steel and 44.5” Flashing shall be PAC-CLAD aluminum (.032 - .063 gauge as specified) or 22’ on aluminum 42.67” COVERAGE WITH 1 LAPPED RIB FOR SIDING 40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING

PAC-CLAD steel (24 gauge or 22 gauge as specified). A 30-year non-prorated MATERIAL 2.667” 1/2” finish warranty can be supplied covering finish performance. ` ` 43 stocked colors (24 gauge steel) 1/2” Corrugated ` ` 15 stocked colors (22 gauge steel) 39.75” Vinyl masking is recommended on all fabrication applications where extra *Note: The M-36 and M-4237.33” panelsCOVERAGE are WITHnot intended 1 LAPPED forRIB use FOR in SIDING the construction of metal buildings or `` structural roof applications.34.67” COVERAGE Please consult WITH 2 withLAPPED Petersen RIBS FOR regarding ROOFING the application of this panel. handling is expected. NOTE: The strippable film must be removed immediately 36 stocked colors (.032 aluminum) 2.667” `` A complete specification is available online at pac-clad.com. 7/8” after installation. 22 stocked colors (.040 aluminum) ` 7/8” Corrugated ` 29 stocked colors (.050 aluminum) ` ` Galvalume Plus available 6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions. FLORIDA BUILDING PRODUCT APPROVALS

Please refer to pac-clad.com or your local

Photo above: factory for specific product approval Sharpsburg Library, Sharpsburg, PA numbers for exposed fastener panels. Architect: Front Studio Architects Photo at left: General Contractor: Franjo Construction Moving Everest Charter School, Chicago, IL Distributor: Brock Associates LLC Architect: TEAM A Profiles: PAC-CLAD 7/8” Corrugated in .032 aluminum Installing contractor: WBR Roofing Colors: Silver, Copper Penny, Cardinal Red, Award Blue, Patina Green Profile: 7/8” Corrugated Panels, smooth and perforated Photography: ©2015 Ed Massery Tom Harris @ Hedrich Blessing Color: Charcoal

28 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 29 Ballet Memphis, Memphis, TN ® PERFORATED METAL Architect: archimania COLORGARD SNOW RETENTION SYSTEM General contractor: Grinder Tabor Grinder Installing contractor: Ralph Jones Sheet Metal Profiles: Snap-Clad, perforated Snap-Clad, Corrugated, perforated Corrugated PERFORATION OPTIONS Colors: Zinc, natural copper material Petersen is stocking the patented ColorGard snow retention Photo: courtesy of archimania system. ColorGard is the only product available which Petersen offers several wall and soffit profiles for perforation will precisely match the color of any Petersen roof panel. in a nearly endless combination of hole sizes and patterns ColorGard achieves this by utilizing a strip of the actual roof to complement virtually any architectural design or need. material, which is then mounted directly into ColorGard for a Perforated metal can provide a contrasting look with any perfect match. This strip can be cut in the field or at non-perforated metal to create visual interest on any project. Petersen’s factory. Perforated panels can be specified to diffuse light, air or sound, or simply for architectural flair. Maximum open area and hole ColorGard utilizes the patented S-5! Clamp for its strength. The size limitations apply for roll-formed panels. Typical applications S-5! technology involves gripping the seam in such a way that include equipment screens, partitions, sign panels, parking there is no penetration to the panel material. S-5! utilizes round- decks, guards, interior acoustical applications and enclosures of point set screws for attachment which are specially made for any kind. Aluminum can be perforated for any project. An extra the S-5! ColorGard or SnoFence™ snow retention system. charge is applied for perforation. Check with local facility for These systems eliminate minimum temperature installation specific panel profiles that can be perforated. requirements and messy adhesives to apply. ColorGard can be installed at any temperature. For more information regarding ColorGard please contact your local Petersen representative.

A NEARLY ENDLESS RANGE OF HOLE SIZES AND SPACING IS AVAILABLE. THE MOST POPULAR EXAMPLES ARE SHOWN BELOW.

COIL AND FLAT SHEET

1/4” Round Holes 3/16” Round 3/16” Round Holes 1/8” Round Holes In addition to offering the industry’s widest selection of 70% 3/8” Staggered Centers 5/16” Staggered Centers ¼” Staggered Centers 1/4” Staggered Centers full PVDF (Kynar) finishes in steel and aluminum, Petersen also 40% Open Area 33% Open Area 51% Open Area 23% Open Area provides mill finish sheet and coil in a variety of gauges and widths. Anodizing-quality 5005-H34, as well as 3003-H14, is stocked in gauges .032 to .125 for all applications that require Sunrise Mainline Toll Plaza, Ft. Lauderdale, FL Owner: Florida Turnpike Enterprise fabrication and post-finishing. With its state-of-the-art, cut-to- Design: RS&H Lead Contractor: MCM Corp length and slitting equipment, Petersen can provide flat sheet Contractor: Allied Architectural Metals and coil to exact specifications. Profile: 7/8” corrugated panels, custom perforated, .125 plate aluminum Color: Silver Metallic

30 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 31 SOFFIT PANELS SOLID SOLID REVEAL SOLID

from .032 aluminum. Panels are 12” wide with a “vee” groove every 6” center-to-center and furnished in continuous lengths of up to 25’. Minimum panel length is 24”. PAC-850 SOFFIT PANELS

PAC-850 Soffit panels utilize an innovative hook-and-grab interlock. These panels are roll-formed from .032 aluminum. Panels are 12” wide with a “vee” groove every 6” center- HALF VENT HALF VENT FLUSH SOLID to-center and furnished in continuous lengths of up to 25’. Minimum panel length is 24”. SOFFIT VENTING

The PAC-750 and PAC-850 Soffit panels can be lanced to allow for airflow and under-eave ventilation. Both PAC-750 and PAC-850 are available fully vented, half vented or solid. See illustrations on page 33 for examples. FULL VENT FULL VENT SOFFIT “J” CHANNEL SOFFIT FLUSH/REVEAL

Petersen can provide soffit “J” Channel as trim to match any of its soffit panels. “J” Channel is available in lengths up to 12’ in Palmer Bank, Taylorville, IL MATERIALS Architect: The Redmond Company matching colors. General contractor: The Redmond Company .032 aluminum 24 gauge steel Installing contractor: E.L. Pruitt Company Profiles: Snap-Clad, Pac-850 Vented Soffit, Flush Panel FLUSH PANELS 1/10/18 Snap.040 Clad - aluminum*Removed arrow and text “Sealant bead (optional)”22 gauge and added steel* “Smooth Panel (Standard) Colors: Charcoal and Slate Gray The Flush panel and Reveal panel may be specified for use as * Limited color availability 1/10/18 Snap Clad - Removed arrow and text “Sealant bead (optional)” and added “Smooth Panel (Standard) 1/10/18 Snap Clad - Removed arrow and text “Sealant bead (optional)” and added “Smooth Panel (Standard) soffit panels. They are roll-formed from .032 aluminum, .040 SOFFIT PANELS SPECS Petersen offers superior design versatility for soffit aluminum, and 24 or 22 gauge steel. Maximum panel length is PAC-750 PAC-850 SOFFIT PANELS 7”, 11”,SOFFIT or 12” O.C. PANELS1” High applications by providing the PAC-750/850 Soffit panels, as 25’ and minimum panel length is 4’. 12" O.C. 1/2"

well as the Flush panel in a variety of gauges and widths. Both 1/10/18 Snap Clad - Removed arrow and text “Sealant bead (optional)” and added “Smooth Panel (Standard) Stiffener beads can be added to the Flush panel for increased MATERIALS SPECS MATERIALS 12" O.C.SPECS 12" O.C.750 pre-formed profiles are effective solutions in soffit projects, 1/2" strength and aesthetics. Stiffener beads are recommended FLUSH / REVEAL 1/2" and with the aluminum substrate can be ventilated .032 aluminum 12” O.C. .032 aluminum 12” O.C. for longer panel lengths. One or two beads are available at no SOFFIT PANELS 750 VENTING OPTIONS750 for increased airflow capacity. 12" O.C. additional cost (see drawings on page 21). 3/8" WIDE VENT PAC-750 SOFFIT PANELS 12" O.C. 12" O.C. FLUSH/REVEAL VENTING 12" O.C.850 1/2" 3/8" 11" and 12" width, .032 aluminum only3/8" Petersen offers a pre-formed soffit panel suitable for both The Flush/Reveal panels only in .032 aluminum are available 750 850 850 commercial and residential use. These panels are roll-formed 12" O.C. 11" or 12" O.C. ventilated. Consult the local factory for venting options. 1" 1" 12" O.C. 12" O.C. 11"12" or O.C. 12" O.C. 11" or 12" O.C. 3/8" 1" 1" Flush Vented (Soffit) Flush Solid (Soffit) ` 1" 1" PRODUCT FEATURES ` 36 stocked colors (.032 aluminum) FLORIDA BUILDING PRODUCT APPROVALS 850 Use for both Wide and Narrow `` NARROW VENT ` 22 stocked colors (.040 aluminum) Please refer to pac-clad.com or your local Flush Vented (Soffit) FlushFlush Vented Solid (Soffit)(Soffit) Flush7", Solid 11" or (Soffit)12" O.C. ` Four profiles available 7", 11"1-1/2" and 12" width, .032 aluminum only `` factory for specific product approval Use for both Wide and Narrow Use for both Wide and Narrow ` Galvalume Plus available 12" O.C. 11" or 12" O.C. 3/16/17 - Rob had us change Flush/Reveal Soffit/ Wall ` Perforation available for ventilation on numbers for soffit panels. 1" (Flush/Reveal soffit only ) Panels to all say “7", 11" or 12" O.C.” aluminum only 1" 1" 1-1/2" 7", 11" or 12" O.C. 1-1/2" 7", 11" or 12" O.C. Added Flush Vented for Flush Wide and Narrow Vented ` ASTM TESTS -website line drawings Soffit Reveal ` 3/16/17 - Rob had us change Flush/Reveal Soffit/ Wall 3/16/171" - Rob had us change Flush/Reveal Soffit/ Wall 1" Roll-formed to exact lengths Panels to all say “7", 11" or 12" O.C.” ` `` OPEN AIR PERCENTAGES (750/850/FLUSH)Flush Vented (Soffit) Flush Solid (Soffit) Panels to all say “7", 11" or 12" O.C.” ` Matching “J” trim available ASTM E330 Tested: Flush panel Use for both Wide and Narrow Added Flush Vented for Flush Wide and Narrow Vented Added Flush Vented for SoffitFlush Wide Reveal and Narrow Vented ` (12” only) and PAC-850 (these percentages are nominal and may -website line drawings -website line drawings Soffit Reveal ` 30-year non-prorated finish warranty `` vary per profile) ASTM 1592 ` 1-1/2" 7", 11" or 12" O.C. MATERIAL ` ` Half vented (750/850) - 6% ` ASTM E283 3/16/17 - Rob had us change Flush/Reveal Soffit/ Wall 1" ` `` Panels to all say “7", 11" or 12" O.C.” ` 43 stocked colors (24 gauge steel) ` Full vented (750/850) - 12% ` ASTM E331 Sullivan’s Island Elementary School, Sullivan Island, SC (Flush/Reveal soffit only ) `` Added Flush Vented for Flush Wide and Narrow Vented `` Wide vent (Flush/Reveal)-website - 12% line drawings Soffit Reveal Owner: Charleston County School District `` AAMA 501.1-05 ` Architect: Cummings and McCrady Architects 15 stocked colors (22 gauge steel) ` Narrow vent (Flush/Reveal) - 6% Installing contractor: Keating Roofing & Sheet Metal Co. (Flush/Reveal soffit only ) Profiles: Tite-Loc Plus, Flush Panels, Flat Sheet Colors: Champagne, Almond

32 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 33 COMPOSITE WALL PANELS PAC-CLAD® FLASHING AND TRIM

Petersen maintains complete flashing fabrication capabilities weathertightness warranty. Assistance with difficult or unusual Pflugerville Elementary School, Pflugerville, TX Owner: Pflugerville Independent School District in each of its plant locations to produce trim. Fabrication flashing conditions also is available by contacting the local Architect: SHW Group General contractor: Bartlett Cocke General Contractors capabilities include press-breaking, shearing, notching and factory. Installing contractor: Dean Contracting Co. Profiles: Composite Panels, Flush Wall Panels welding. Colors: Copper Penny, Silver Metallic In addition to standard details, Petersen can provide custom Each trim accessory is factory-formed in a gauge appropriate fabrication to meet the most exacting requirements. Please to the end-use application. Precisely matched color and finish contact Petersen for assistance with custom architectural quality is assured. For projects in which installer fabrication is elements. preferred, flat sheet is available for immediate shipment. Vinyl masking is recommended on all fabrication applications A complete set of flashing details for each panel profile is where extra handling is expected. NOTE: The strippable film available at pac-clad.com, and includes detailed drawings must be removed immediately after installation. for many flashing conditions. These flashing details should be followed, especially for any projects requiring a

ANODIZED ALUMINUM

Petersen offers another dimension in design flexibility with its The PAC-3000 RS is a rain-screen system that eliminates series of composite wall panels. PAC’s panel systems provide the use of caulk, utilizing clean reveals for an architecturally PAC 500 BRONZE ANODIZED ALUMINUM PAC 300 CLEAR ANODIZED ALUMINUM

unmatched performance and stunning visual effects for any pleasing system. The system is constructed with metal Petersen’s PAC 500 anodized finishes include a wide range of PAC 300 clear anodized aluminum consists of anodized- commercialCOMPOSITE or retail WALL application. PANELS composite material (MCM), available in a wide range of finishes architectural bronzes and black. A complete range of bronze quality 5005-H34 aluminum sheet, giving a .0003 thick clear and colors to complement any design scheme. Extrusions are The PAC-300010-16 x 1" CS panels are comprised of an .020 face and shades and black can be achieved. PAC 500 is highly resistant anodized coating. Coil anodizing allows for exceptional control TEK 3 FASTENER VAPOR BARRIER fixed to the perimeter of the panel and nest into the extruded back skin thermobonded to a polyethylene or fire-retardant to ultraviolet light. With anodized finishes, a color variance is over uniformity of appearance. PAC 300 anodized aluminum is track which is attached to the substrate. The result is a free- core. Panels are formed by D????a rout-and-return process utilizing to be expected from batch to batch, so please order enough stocked in gauges .032-.125. E floating panel installation since the panel is not fastened 1"computer-controlled TYP. routing equipment. This state-of-the- sheet or coil to complete a project. INU to the substrate. art fabrication ensures tight tolerances and accurate panel .125 ALUM. PANEL ATTACHMENT CLIPS COLORS dimensions.CONT Staggered5/8" OR angle clips mounted to the panel allow S AS REQ'D CONTINUOUS .032 .040 .050 .063 .080 .125 ANDfor BACKER eachDI ROD panel to be installed and adjusted individually. The PAC-CLAD colors on pages 8-9 do not apply to composite PAC-3000 AP panels. Consult Petersen rep for color options. PAC 500

PLYWOOD SUBSTRATE CHAMPAGNE

10-16 X 1" COMPOSITE WALL PANELS TEK 3 FASTENER PRODUCT FEATURES LIGHT BRONZE 10-16 x 1" VAPOR BARRIER TEK 3 FASTENER VAPOR BARRIER `` Available in a wide variety of MEDIUM BRONZE D???? non-PAC-CLAD colors and finishes E ` 1.625" ` Precise fabrication to meet exacting DARK BRONZE 1.00" 1" TYP. NU I tolerances COMPOSITE TRACK BLACK .500" 3mm OR 4mm ATTACHMENT CLIPS `` .125 ALUM. PANEL Rout-and-return fabrication FACTORY APPLIED COMPOSITE PANELS CONT5/8" OR CONTINUOUS ALUMINUM S AS REQ'D CONTINUOUS `` EXTRUSION DI Welded corners available PAC 300 PAC-3000 CS ANDPAC-3000 BACKER ROD RS PAC-3000 AP PAC-3000 RS MATERIAL CLEAR PLYWOOD SUBSTRATE `` 10-16 x 1" 3mm, 4mm, 6mm – Composite TEK 3 FASTENER 10-16 X 1" VAPOR BARRIER TEK 3 FASTENER ` ` .063 - .125 Mill Finish Aluminum VAPOR BARRIER ` } ` Zinc Stainless steel `` 1" TYP. Anodized aluminum 1.625" 1.00"

3mm OR 4mm ATTACHMENT CLIPS TESTS COMPOSITE TRACK COMPOSITE PANELS 5/8" OR .500" 3mm OR 4mm AS REQ'D COMPOSITE PANELS ` CONTINUOUS FACTORY APPLIED ` CONTINUOUS ALUMINUM ASTM E283*, ASTM E330*, ASTM E331* EXTRUSION AND BACKER ROD * Composite material only PAC-3000 CS PAC-3000 RS

10-16 x 1" 34 800-PAC-CLAD | PAC-CLAD.COM TEK 3 FASTENER 800-PAC-CLAD | PAC-CLAD.COM 35 VAPOR BARRIER

1" TYP.

3mm OR 4mm ATTACHMENT CLIPS COMPOSITE PANELS 5/8" OR AS REQ'D CONTINUOUS

AND BACKER ROD PAC-3000 CS FASCIA SYSTEMS COPING SYSTEMS

As a key protective element, roof edge and perimeter products Each project is custom-fabricated and produced to exacting University of Texas at Dallas Student Housing Living/Learning Center II, Richardson, TX are necessary to maintain the integrity of all flat roofing jobsite requirements to ensure proper fit and superior Owner: University of Texas at Dallas Architect: Jacobs Engineering Group systems. Petersen offers a line of fascia and coping products functionality. Available in 45 PAC-CLAD colors, as well as General contractor: Hill & Wilkinson Construction Group Installing contractor: American Roofing & Metal Co. Inc. to meet the most stringent engineering requirements as well anodized finishes, Petersen fascia products can complement Products: Anchor-Tite Coping as provide the ideal finishing touch for superior aesthetics. any building’s exterior. Additionally, the products are designed Color: Silver Metallic FASCIA with ease of installation as a priority, and 12’ lengths reduce material handling for an estimated 20 to 40 percent savings Designed with strength and performance in mind, PAC-Tite on labor. Competitive pricing and superior lead times allow the fascia products are tested to ANSI/SPRI/FM 4435-ES-1 project to stay on budget and on schedule. standards for full compliance with the specification. Available in a multitude of steel and aluminum gauges and face heights, Petersen’s fascia and coping systems typically exceed PAC-Tite fascia can meet the needs of any project condition. project specifications. PAC’s roof edge systems provide A lifetime 215 mph warranty is available for PAC-Tite fascia unmatched uplift protection for single-ply and built-up/ products. For additional design options, Petersen provides the modified (BUM) roof systems. PAC-LOC and the Snap Edge fascia systems. Fascia system features include:

` ` Superior, efficient design for ease of installation ` ` Extensively tested for reliable, long-term performance ` PAC SNAP EDGE FASCIA ` Welded corners and scuppers available (for aluminum products only) COPING Coping system features include: `` ` Wide variety of colors and finishes Petersen’s coping systems are the complete package, ` Elimination of field-crimping for certain products `` providing specifiers and contractors with unmatched strength, ` Pre-punched, slotted holes for precise fastener placement ` Wide variety of colors and finishes `` beauty, ease of installation and verified performance through ` Non-penetrating design maintains watertightness integrity ` Compliant with most relevant building codes rigorous testing. Available in many versions, PAC-Tite coping `` `` Reusable and recyclable material systems provide versatility for use on a variety of parapet Superior, efficient design for ease of installation `` ` Custom and radius capabilities available conditions, including flat, tapered and existing slope. ` Custom fabricated to specific job requirements to ensure Fully Adhered/ Stone Ballast Built-Up/ superior fit Mechanically Single-Ply (SB) Modified (BUM) Featuring a snap-on design, the coping products ensure Attached Single- `` Ply (FA) positive attachment and stability to the roof edge system. Extensively tested for reliable, long-term performance ` PAC-Tite, PAC-Tite Gold and Continuous Cleat coping systems ` Miami-Dade-approved coping system: PAC-Tite PAC EXTENDED SNAP EDGE FASCIA PAC-TITE WT FASCIA PAC-TITE WT EXTENDED FASCIA are FM-approved for wind uplift protection, and tested per ` ` Lifetime 215 mph warranty for PAC-Tite Gold and 20-year, the ANSI/SPRI/FM 4435 ES-1 Standard. Superior engineering 120-mph warranty for PAC-Tite and Continuous Cleat coping does not compromise the coping system’s simplicity, as it is systems designed for easy installation to reduce labor costs. ` ` Convenient 12’ lengths Coping can be customized to meet any unique design ` ` Reusable and recyclable material requirement including wall widths up to 32” and radius ` ` Custom and radius capabilities available conditions, and precise fabrication can produce miters and transitions to the most exacting demands. Fully Adhered/ Built-Up/Modified (BUM) Fully Adhered/ Built-Up/Modified (BUM) Fully Adhered/ Built-Up/Modified (BUM) Mechanically Attached Mechanically Attached Mechanically Attached Single-Ply (FA) Single-Ply (FA) Single-Ply (FA)

PAC-TITE PAC-TITE PAC-CONTINUOUS PAC-TITE WT CANTED FASCIA PAC-LOC FASCIA PAC-TITE ANGULAR FASCIA COPING GOLD COPING CLEAT COPING

WT Extended Canted WT Canted Fascia w/ PAC-LOC FASCIA PAC-LOC Fully Adhered/ Built-Up/ Tapered Flat Existing Slope Fascia w/ Galvanized Galvanized Waterdam 2000 FASCIA 3000 Mechanically Modified with Nailer Waterdam Attached (BUM) Single-Ply (FA)

36 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 37 GENERAL CONSIDERATIONS FIRE RATINGS Petersen also offers a coastal finish warranty for projects located in the vicinity of the coast or within saltwater The following is a summary of conditions and considerations PAC-CLAD panels have been evaluated by Underwriters environments. Aluminum substrates, with stainless steel clips that Petersen considers important when specifying Laboratories for inclusion in a variety of fire-rated and fasteners, must be used to qualify for the coastal warranty. PAC-CLAD metal products. For more project-specific “P-Assemblies” and are classified in section CETW of the UL information, please contact 800-PAC-CLAD. Fire Resistance Directory - Vol. 1. Several panel assemblies For projects utilizing Snap-Clad, Tite-Loc or Tite-Loc Plus have been evaluated as Class A fire-rated. Contact PAC for FINISHES factory-formed standing-seam panels, weathertightness complete information on components and assemblies. warranties for terms up to 20-years are available. Projects must PAC-CLAD panels are available standard with a 70% full OIL CANNING be submitted and pre-approved by PAC technical personnel PVDF (Kynar) finish. Please refer to the color information prior to ordering. on pages 8 and 9 for color selection. Samples and photo- All Petersen material is prime-quality aluminum, G-90 accurate color charts are available for your assistance. galvanized or galvalume steel. All materials are specified for STORAGE roll-forming applications. Panels are inspected in the plant SPECIAL COLORS Materials should be stored in a clean, dry place. Suitable for flatness before shipment. Jobsite conditions such as facilities for storage and protection of material should be Special colors are available for most applications of greater temperature variation, unlevel substrate and/or improper provided at the job site. Store materials out of traffic areas to

than 10,000 sq. ft. and may be applied to either aluminum installation may promote oil canning. Oil canning does not prevent dents, bending, abrasion, etc. or G-90 galvanized steel. Contact Petersen for information affect the finish or structural integrity of the panel and is concerning costs and availability. therefore not cause for rejection. LIMITATIONS ON LIABILITY INSTALLATION WARRANTY Neither Petersen nor its customer shall be liable for special, indirect or consequential damages. The liability of Petersen Special care must be taken to ensure that panels are installed A 30-year finish warranty is available covering cracking, peeling in the event of the sale of its products shall be limited to over a flat substrate. For roofing applications, panels typically and color fade on all PAC-CLAD applications. PAC-CLAD is a replacement of any defective or nonconforming products or must be installed over 5/8” or 3/4” plywood decking with ice and 70% full PVDF (Kynar) finish and therefore carries the highest- refund of the purchase price. water shield horizontally overlayed from the eave to the ridge. quality 30-year non-prorated finish warranty available. Finish It is recommended that clips be installed on 18” centers for warranty terms for Cardinal Red, Award Blue , Weathered all applications except Snap-Clad, Tite-Loc Plus and Tite- Copper, Weathered Steel and all metallic finishes vary slightly. Loc (consult specific UL Construction assemblies for clip LENGTHS Please refer to pac-clad.com for further details. spacing). Consult a local architect/engineer for requirements of local codes and conditions. All panels are cut to custom lengths before roll-forming and are available in lengths up to 64’. See specific product ACCESSORIES Summit Credit Union, Muskego, WI pages for maximum panel lengths. Minimum length is 4’. Architect: Strang Inc. Consult factory for longer lengths. Lengths are accurate to General contractor: J.H. Findorff & Son Inc. Most applications require additional metalwork including Installing contractor: Alois Roofing & Sheet Metal fascia, storefront trim, copings, gravel stops, downspouts, 1/4”. Custom cut-to-length service is available at no cost and Profiles: Snap-Clad, Flush Soffit, Precision Series HWP, S-5! ColorGard Color: Silver Metallic etc. Such metalwork may be specified for fabrication by helps to improve project economy. manufacturer or for fabrication from flat sheet as provided by PANEL WIDTHS manufacturer. Flashings fabricated from PAC-CLAD flat sheet are fully covered under Petersen’s 30-year finish warranty. Most PAC-CLAD panels are available in non-standard on-center dimensions. Contact Petersen for product PAC-CLAD flat sheet provides an exact color match to availability and cost. PAC-CLAD panel standard widths PAC-CLAD panels. PAC-CLAD flat sheets, coil and fabricated are nominal and could vary. trim accessories are available with a strippable masking applied. This masking is recommended on all applications PITCH requiring extra handling. NOTE: This strippable film must be Tite-Loc panels are designed for a roof pitch of 1/2:12 or removed immediately after installation. greater. Snap-Clad panels have been designed to be PANEL CONDITIONS/VARIATIONS installed on applications as low as 2:12 pitch. Redi-Roof panels and Snap-On panels have been designed for a Pencil ribs (also known as stiffening beads) and striations minimum 3:12 pitch. Greater pitch may be required in snow must be requested by the customer. country and in areas of extreme climate conditions.

Photo above: Private Residence, Florida Architect: T. S. Adams Studio Architects General Contractor: Ray Jackson Construction Installing contractor: Cartercraft Roofing Profiles: PAC-150, Flush Panels Colors: Weathered Zinc, Champagne

38 800-PAC-CLAD | PAC-CLAD.COM 800-PAC-CLAD | PAC-CLAD.COM 39 Richland Two Institute of Innovation, Columbia, SC Architect: LS3P General contractor: MB Kahn Installing Contractor: Watts & Associates Roofing Material Distributor: ABC Supply Profiles: Reveal & Flush Wall Panels, Tite-Loc Plus, HWP Colors: Almond, Slate Gray, Sierra Tan, Interstate Blue, Silver

Otto M. Budig Theater, Cincinnati Owner: Cincinnati Shakespeare Co.  SNAP-CLAD PANELS Architect: GBBN Architects General contractor: Messer Construction Installing contractor (roof panels): Tecta America Zero Co.  Installing contractor (wall panels): ProClad Inc. TITE-LOC PANELS Profiles: 7/8” Corrugated, Perforated Corrugated, Flat Sheet Colors: Champagne metallic, custom color Classic Bronze metallic  SNAP-ON PANELS

 REDI-ROOF PANELS

 SOFFIT PANELS

 PRECISION SERIES WALL PANELS

 FLUSH PANELS

 EXPOSED FASTENER PANELS

 FASCIA SYSTEMS

 COPING SYSTEMS

 COIL AND FLAT SHEET

 

HQ: 1005 Tonne Road 9060 Junction Drive 10551 PAC Road 102 Northpoint Parkway 1800 S. 7th Ave., Suite 130 1885 Station Parkway NW, Suite B Elk Grove Village, IL 60007 Annapolis Junction, MD 20701 Tyler, TX 75707 Acworth, GA 30102 Phoenix, AZ 85007 Andover, MN 55304 P: 800-PAC-CLAD P: 800-344-1400 P: 800-441-8661 P: 800-272-4482 P: 833-750-1935 P: 877-571-2025 F: 800-722-7150 F: 301-953-7627 F: 903-581-8592 F: 770-420-2533 F: 602-254-6504 F: 866-901-2935

800-PAC-CLAD | PAC-CLAD.COM PAC-CLAD® is a registered trademark of Petersen Aluminum Corporation. The PAC-CLAD finish is 70% full polyvinylidene fluoride (PVDF). 2/18

800-PAC-CLAD | PAC-CLAD.COM