<<

LEGEND: 2017-09 E EXHAUST FAN EXHAUST FAN TO GFI TERMINATE TO SWITCH OUTSIDE AND BE MOUNTED LIGHT FIXTURE SEPARATELY SWITCHED FROM OUTLET W/ GROUND FAULT CIRCUIT INTERRUPTER E GFI TAMPER PROOF BATH 15 AMPERE CIRCUIT SUPPLY TO 1'-0" 20 AMPERE CIRCUIT BATHROOM RECEPTACLES ONLY BATH WATER EFFICIENT E RECEPTACLES CAN BE LOCATED ON SIDE FIXTURES REQUIRED: OR FACE OF IF IT IS LOCATED UPGRADE TO: WITHIN 12" BELOW THE COUNTERTOP FIXTURE(S) NON-COMPLIANT FLOW RATE (MAX. FLOW RATES) GFI WATER > 1.6 GAL/FLUSH 1.28 GAL/FLUSH SHOWERHEAD @ 80 PSI > 2.5 GAL/MIN 2.00 GAL/MIN BATH FAUCET @ 60 PSI > 2.2 GAL/MIN 1.20 GAL/MIN PLAN: ELECTRICAL LOCATIONS FAUCET @ 60 PSI > 2.2 GAL/MIN 1.80 GAL/MIN

CONSTRUCTION NOTES: ACCEPTABLE MATERIALS FOR BACKER BOARD WITHIN 1. MINIMUM CLEAR AREA OF 30" WIDTH X 24" DEPTH IS TUB AND COMPARTMENTS: REQUIRED IN FRONT OF ALL FIXTURES (, SHOWER, MATERIAL STANDARD , BATH) GLASS MAT GYPSUM 2. WATER PIPE PLUMBING IS PROHIBITED IN EXTERIOR ASTM C1178 BACKING PANEL 3. ALL EXTERIOR WALLS/ROOFS/ EXPOSED DURING NON-ASBESTOS FIBER-CEMENT ASTM C1288 OR ISO CONSTRUCTION SHALL BE INSULATED ONE RECEPTACLE CAN MEET THE BACKER BOARD 8336, CATEGORY C REQUIREMENT IF 3' OF THE OUTSIDE 4. IT IS UNLAWFUL TO CONCEAL CRACKS, HOLES, OR OTHER NON-ASBESTOS FIBER-MAT REINFORCED IMPERFECTIONS IN MATERIALS BY WELDING, BRAZING, OR EDGE OF EACH BASIN ASTM C1325 CEMENTITIOUS BACKER UNIT SOLDERING, OR BY USING THEREIN OR THEREON A PAINT, WAX, TAR, SOLVENT CEMENT, OR OTHER LEAK-SEALING OR REPAIR AGENT 5. ALL JOINTS, PENETRATIONS, AND OTHER OPENINGS IN BACKER BOARD, THE ENVELOPE ABOUT THE AREA OF WORK SEE TABLE ABOVE SHALL BE CAULKED, WEATHER STRIPPED, OR OTHERWISE SEALED MIN. 2" DRAIN REQ. 3'-0" FOR LIFE SAFETY NOTES: 1. SMOKE AND CARBON MONOXIDE ALARMS, WITH 10 YEAR LINING MATERIAL AT BATTERY AND SFM LISTED, SHALL BE INSTALLED ON THE

1'-0" LEAST 3" ABOVE DAM OR WALL AT: · SLEEPING CURB 2" MIN. - · AREA/(S) ADJACENT TO SLEEPING ROOMS 9" MAX. · EACH STORY OF THE BUILDING · AT LEAST ONE WALL RECEPTACLE MIN SLOPE 1/4" PER FOOT GFCI OUTLET SHALL BE @ SUBSTRATE ELECTRICAL NOTES: INSTALLED IN THIS AREA 1. MINIMUM ONE 20-AMP CIRCUIT FOR BATHROOM OUTLETS BATHROOM ELEVATIONS STANDING WATER INSPECTION REQUIRED AND/OR PROVIDE A DEDICATED 20-AMP CIRCUIT FOR EACH FOR SHOWER PAN(S) PRIOR TO COVERING BATHROOM, BATH LIGHTING SHALL NOT BE ON AN OUTLET CIRCUIT 2. ALL RECEPTACLES SHALL BE LISTED TAMPER RESISTANT, SHOWER VALVE MUST BE IN A GFCI PROTECTED, AND ARC FAULT PROTECTED POSITION TO TURN WATER ON 3. RECESSED LUMINARIES SHALL BE RATED FOR ZERO WITHOUT GETTING WET CLEARANCE INSULATION COVER (IC) AND AIR-TIGHT CLEAR- SPACE OF 4. LUMINARIES WITHIN OR ABOVE SHOWERS AND TUBS 6'-8" MIN. MIN. 22" REQ. SHALL BE LISTED FOR WET LOCATIONS IN FRONT OF ALL MUST SWING OUT 5. WHERE A FIXTURE COMES IN CONTACT WITH THE WALL FIXTURES OR , THE JOINT BETWEEN THE FIXTURE AND THE TIP SHEET (TOILET, SHOWER, SAFETY GLAZING WALL OR FLOOR SHALL BE MADE WATERTIGHT RESIDENTIAL BATHROOM REMODEL SINK, BATH) (TEMPERED GLASS) LIGHTING EFFICIENCY NOTES: 30" DIA. MIN. CLEAR SPACE / 1024 1. IN BATHROOMS AT LEAST ONE LUMINAIRE SHALL BE SQ. INCH MIN. SEAT CANNOT CONTROLLED BY A VACANCY SENSOR ENCROACH INTO REQUIRED SPACE 2. DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINARIES REQUIRED TO HAVE LIGHT SOURCES SLOPED BATHROOM CEILINGS SHOWERS COMPLIANT WITH THE REFERENCE JOINT APPENDIX JA8